Luminous emittance 1:
Page 1
Ecofire Forest
07.06.2013
Birou / Summary
Height of Room: 2.800 m, Mounting Height: 2.889 m, Light loss factor: 0.90 Surface Workplane Floor Ceiling Walls (4) [%] / 20 70 50 Eav [lx] 373 307 63 140 Emin [lx] 161 182 45 49
Values in Lux, Scale 1:45 Emax [lx] 607 422 82 362 u0 0.431 0.593 0.712 /
Workplane: UGR LengthwaysAcross to luminaire axis Height: 0.800 m Left Wall 14 17 Grid: 64 x 64 Points Lower Wall 15 16 Boundary Zone: 0.000 m (CIE, SHR = 0.25.) Illuminance Quotient (according to LG7): Walls / Working Plane: 0.349, Ceiling / Working Plane: 0.169. Proportion of points with less than 400 lx (for IEQ-7): 58.45%. Luminaire Parts List No. 1 Pieces 3 Designation (Correction Factor) ELBA FIRI-03-418 D (1.000) Total: (Luminaire) [lm] 3401 10204 Total: (Lamps) [lm] 5400 16200 P [W] 84.0 252.0
Specific connected load: 12.17 W/m = 3.26 W/m/100 lx (Ground area: 20.70 m)
Page 2
Ecofire Forest
07.06.2013
Rho [%] 20 70 50 50 50 50
from ( [m] | [m] ) / / ( 0.000 | 0.000 ) ( 6.000 | 0.000 ) ( 6.000 | 3.450 ) ( 0.000 | 3.450 )
towards ( [m] | [m] ) / / ( 6.000 | 0.000 ) ( 6.000 | 3.450 ) ( 0.000 | 3.450 ) ( 0.000 | 0.000 )
Page 3
Ecofire Forest
07.06.2013
Page 4