Diesel Generator Set Exclusively from your Caterpillar dealer

EU Stage II Emissions Compliant

Output Ratings
Generating Set Model 380-415V,50Hz Prime* 16.5 kVA 13.2 kW 220/127V, 60 Hz 19.4 kVA 15.5 kW * Refer to ratings definitions on page 4. Ratings at 0.8 power factor. Standby* 18.0 kVA 14.4 kW 21.3 kVA 17.0 kW

Technical Data
Engine Make & Model: Alternator Model: Base Frame Type: Circuit Breaker Type: Frequency: Engine Speed: RPM Fuel Tank Capacity: litres (US gal) Fuel Consumption, Prime: l/hr (US gal/hr) Fuel Consumption, Standby : l/hr (US gal/hr) 4.4 (1.2) 4.8 (1.3) Perkins 404D-22G1 LL1014L Heavy Duty Fabricated Steel 3 Pole MCB 50 Hz 1500 45 (11.9) 5.2 (1.4) 5.7 (1.5) 60 Hz 1800

Engine Techncial Data


Physical Data
Manufacturer: Model: No. of Cylinders/Alignment: Cycle: Induction: Cooling Method: Governing Type: Governing Class: Compression Ratio: Displacement: l (cu.in) Bore/Stroke: mm (in) Moment of Inertia: kg m (lb. in) Engine Electrical System: -Voltage/Ground: -Battery Charger Amps: Weight: kg (lb) - Dry: - Wet: 12/Negative 65 242 (534) 251 (554) Perkins 404D-22G1 4 / In Line 4 Stroke Naturally Aspirated Water Mechanical ISO 8528 G2 23.3:1 2.2 (135.2) 84.0 (3.3)/100.0 (3.9) 2.72 (9308)

Lubrication system
Oil Filter Type: Total Oil Capacity l (US gal): Oil Pan l (US gal): Oil Type: Cooling Method: Spin-On, Full Flow 10.6 (2.8) 8.9 (2.4) AP1CH4 15W-40 N/A

Performance
Engine Speed: RPM Gross Engine Power: kW (hp) -Standby: -Prime: BMEP: kPa (psi) -Standby: -Prime: Regenerative Power: kW

50 Hz
1500 18.0 (24.0) 16.2 (22.0) 649.0 (94.2) 585.0 (84.8) 5.6

60 Hz
1800 21.5 (29.0) 19.4 (26.0) 647.0 (93.8) 583.0 (84.6) 7.2

Fuel System
Fuel Filter Type: Replaceable Element Recommended Fuel: 110% Load Prime 50 Hz 60 Hz Standby 50 Hz 60 Hz 4.8 (1.3) 5.7 (1.5) 3.7 (1.0) 4.4 (1.2) 2.7 (0.7) 3.3 (0.9) 4.8 (1.3) 5.7 (1.5) 4.4 (1.2) 5.2 (1.4) 3.4 (0.9) 4.1 (1.1) 2.6 (0.7) 3.1 (0.8) Class A2 Diesel Fuel Consumption: l/hr (US gal/hr) 100% Load 75% Load 50% Load

Air System
Air Filter Type: Combustion Air Flow: m/min (cfm) -Standby: -Prime: Max. Combustion Air Intake Restriction: kPa (in H2O) Radiator Cooling Air Flow: m/min (cfm) External Restriction to Cooling Air Flow: Pa (in H2O)

50 Hz
Replaceable Element 1.5 (51) 1.5 (51) 3.0 (12.0) 33.0 (1165) 125 (0.5)

60 Hz

1.7 (61) 1.7 (61) 3.0 (12.0) 41.4 (1462) 125 (0.5)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Cooling System
Cooling System Capacity: l (US gal) Water Pump Type: Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby: -Prime: Heat Radiation to Room: kW (Btu/min) -Standby: -Prime: Radiator Fan Load: kW (hp)

50 Hz
6.5 (1.7)

60 Hz
6.5 (1.7)

Exhaust System
Silencer Type: Silencer Noise Reduction Pressure Drop Across Silencer System: kPa (in Hg) Silencer Noise Reduction

50 Hz
Level 1

60 Hz

263-0765 (1) 0.70 (0.207) 1.40 (0.413) 27 10.0 (3.0) 3.7 (131) 3.4 (120) 394 (740) 361 (681) 20 10.0 (3.0) 4.0 (141) 3.7 (131) 434 (812) 379 (714)

Centrifugal

15.2 (864) 13.7 (779) 3.1 (176) 2.5 (142) 0.2 (0.3)

17.2 (978) 15.5 (881) 3.2 (182) 2.7 (154) 0.4 (0.5)

Level: dB Max. Allowable Back Pressure: kPa (in. Hg) Exhaust Gas Flow: m/min (cfm) -Standby: -Prime: Exhaust Gas Temperature: C (F) m/min (cfm) -Standby: -Prime:

Consult your Olympian representative for more information

Alternator Performance Data


50 Hz Data Item
415/240V 400/230V 380/220V

60 Hz
220/127V

Motor Starting Capability* kVA

30

29

26

29

Short Circuit Capacity** %

Reactances: Per Unit

Xd X'd X''d

2.070 0.140 0.070

2.230 0.150 0.075

2.470 0.170 0.083

2.600 0.180 0.088

Reactances shown are applicable to standby ratings. * Based on 30% voltage dip.

Alternator Technical Data


Physical Data
Manufacturer: Model: No. of Bearings: Insulation Class: Winding Pitch - Code: Wires: Ingress Protection Rating: Excitation System: AVR Model: OLYMPIAN LL1014L 1 H 2/3 - 6 12 IP23 SHUNT R250

Operating Data
Overspeed: RPM Voltage Regulation (steady state) (% ): Wave Form NEMA = TIF: Wave Form IEC = THF: Total Harmonic Content LL/LN: Radio Interference: 2250 +/- 0.5 50 2.0% 4.0%

Supression is in line with European Standard EN61000-6

Radiant Heat: kW (Btu/min) -50 Hz: -60 Hz: 2.8 (159) 3.3 (188)

Consult your Olympian representative for more information

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

Technical Data
Voltage
kVA
415/240V 400/230V 380/220V 16.5 16.5 16.5

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

Prime
kW
13.2 13.2 13.2

Standby
kVA
18.0 18.0 18.0

Voltage
kW
14.4 14.4 14.4 220/127V 19.4

Prime
kVA kW

Standby
kVA kW

15.5

21.3

17.0

Weights & Dimensions


Weights: kg (lb)
Net (+ lube oil) Wet (+ lube oil & coolant) Fuel, lube oil & coolant 447 (985) 454 (1001) 492 (1085)

Dimensions: mm (in)
Length Width Height 1320 (52.0) 552 (21.7) 1179 (46.4)

Note: for installation. See drawings for detail.

general

dimension

General Data
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model

Documents
Operation and maintenance manuals provided. Wiring diagrams included.

Quality Standards Prime Rating


These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. BS4999, BS5000, BSEN60034, BSEN61000, IEC60034.

Warranty
All equipment carried full manufacturer's warranty.

Standard Reference Conditions


Note: Standard reference conditions 25C (77F) air Inlet Temp, 100m (328ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with speci c gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Discretion is recommended when distributing. Market: International LEHF3043-06 CAT, CATERPILLAR, their respective logos and ''Caterpillar Yellow'', as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

www.CAT-ElectricPower.com 2008 Caterpillar All rights reserved. Printed in U.S.A.