Académique Documents
Professionnel Documents
Culture Documents
Primary Applications
Switching Three phase motors Switching Heaters Switching Transformers SCR Output for heavy inductrial loads Load voltage 600 VAC models available AC and DC controlled ranges available 90 205 Amps available on request 17 80 VAC Input Control voltage available on request
Input Specifications
TYPE
Control voltage range Control current range Pick-up voltage Drop-out voltage Input resistance
S3PDJ 4 10/16/../90
4 32 VDC <=25 mA 4 VDC 1 VDC Current Regulation
Output Specifications
TYPE CASING Current range with proper Heatsink (IT) Repetitive peak off-state voltage (VDRM) Vpk Voltage Drop @ Rated Current (VTM) Load Voltage Range Surge Current (I) 50 Hz non-Repetitive 60 Hz t= 20msecs. (ITMS) Off-state leakage current @ (IDRM) Turn-on (max.) / pick-up Turn-off (max.) / drop-out 50Hz Holding current (IH) Dv/Dt @ Voltage I T Fusing (10 ms.)
2
400 A 420 A
<10 mA DC input models: 10 msecs AC input models: 20msecs DC input models: 10 msecs AC input models: 30msecs 50 mA 200 V/ s 72 A S
2
Note: Turn-ON time for Random series = 0.02msec for DC control input For Load voltage Range 48-660 VAC Type: S3PDJ-6-.. above 50 amps
General Specifications
Frequency Range Dielectric Strength (Input to Output to Base) Weight Storage Temp. Junction Temp. 47 70 Hz 4000 Vrms Approx. 300 g 40 C to 100 C 100 C
Dimensions
Casing A Casing B
Note: casing B above 50A SSR Note: casing A for below 40A SSR
Derating Curve
Schematic