HV Motor datasheet (Calcination package)

DOCUMENT No. 0287-10-XZ-DS-6517 Rev. A


Page 1 of 1

Data sheet for High voltage Squirrel Cage induction motor ELECTRICAL DESIGN DATA
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 Motor tag nos. By Vendor Voltage (V) 6600+6% System Fault level (kA) 25KA Type of motor Squirrel cage Design Ambient temp (C) 50C Cable size Later Enclosure type IP-55 Haz. Area classification,Gas group Safe area Reacceleration Yes/ No Type of H.V termimal /box Phase segregated Method of starting Direct-on-Line Type of Explosion Protection: Ex(n)/Ex(e)/Ex(d)/Ex(p) Type of driver mounting/suggested kw/Manufacturer Shaft kW/ kW at max.load Speed/rotation of equip from coupling end Starting/max. Torque required-mkg WK of equipment Including/excluding flywhel-kgm Maximum thrust/ pulsation rate Equipment/coupling type Starting condition - On no load/ Under loaded condition Phase 3 Frequency (Hz) 50Hz+3% System Earthing Resistance earthed Duty Continuous Temp rise (C) Type Al. conductor XLPE cable Cooling TEFC Location Outdoor/ Indoor Differential protection C.Ts Required/ Not Required

Applicable standards

Technical particulars from driven equipment manufacturer

Technical particulars from motor manufacturer


Manufacturer kW Rating No of poles Frame designation Mounting Full load current (A) Full load speed (rpm) Full load torque (mkg) Starting torque (as a % of FLT) Pull out torque (as a % of FLT) Starting current at 100% Voltage (A) Rotation viewed from coupling end Starting time at 80% V (sec) At 100% V (sec) Locked rotor with stand time(cold/hot) sec. at 80% V (sec) At 100%V (sec) Time (Te) for increased safety motors at 100% voltage (sec) WK of motor (kg m) Power factor at 100% load Power factor at 75% load Effeciency at 100% load Efficiency at 75% load Space heater watts/volts Terminal box type No. of terminals Type of RTD and BTD provided No. Of RTDs and BTDs provided Heating time constant (min) Cooling time constant (min) Bearing type/ no. DE Bearing type/ no. NDE Lubrication type Weight of motor (kg)(motor/stator/rotor) Design of fan rotation Universal/ fixed/ can be changed Canopy Required/ Not required

1. 2.

Recommended list of maintenance spares for two years operation shall include the following as minimum: a) Bearing DE/NDE one set b) Terminal box cover with screws c) Fan d) Terminal block Starting time calculations shall be based on operating conditions specified in material requisition eg., open valve condition / closed valve condition at no load/ under load as applicable.

A Rev. No

13.08.04 Date

Issued with MR Purpose

NMS Prepared by

RM Checked by

RPG Approved by

Format No. EIL 1641-1924 Rev. 1

Copyright EIL All rights reserved