Circuit protection and control devices

0.5 to 6300 A

LV product characteristics

2005

The Guiding System, the new way to create your electrical installations
A comprehensive offer of products with consistent design The Guiding System is first and foremost a Merlin Gerin product offer covering all electrical distribution needs. However, what makes all the difference is that these products have been designed to operate together: mechanical and electrical compatibility, interoperability, modularity, communication. Thus the electrical installation is both optimised and more efficient: better continuity of supply, enhanced safety for people and equipment, guaranteed upgradeability, effective monitoring and control. Tools to simplify design and implementation With the Guiding System, you have a comprehensive range of tools - the Guiding Tools - that will help you increase your product knowledge and product utilisation. Of course this is in compliance with current standards and procedures. These tools include technical booklets and guides, design aid software, training courses, etc. and are regularly updated.

For a genuine partnership with you Because each electrical installation is unique, there is no standard solution. With the Guiding System, the variety of combinations allows for genuine customisation solutions. You can create and implement electrical installations to meet your creative requirements and design knowledge. You and Merlin Gerins Guiding System form a genuine partnership. For more details on the Guiding System, consult www.merlin-gerin.com

A consistent design of offers from Medium Voltage to Ultra terminal

All Merlin Gerin offers are designed according to electrical, mechanical and communication consistency rules. The products express this consistency by their overall design and shared ergonomics.
Electrical consistency: Each product complies with or enhances system performance at coordination level: breaking capacity, Isc, temperature rise, etc. for more safety, continuity of supply (discrimination) or economic optimisation (cascading). The leading edge technologies employed in Merlin Gerins Guiding System ensure high performance levels in discrimination and cascading of protection devices, electrodynamic withstand of switches and current distributors, heat loss of devices, distribution blocks and enclosures. Likewise, inter-product ElectroMagnetic Compatibilty (EMC) is guaranteed.

Discrimination guarantees co-ordination between the operating characteristics of serial-connected circuit-breakers. Should a fault occurs downstream, only the circuit-breaker placed immediately upstream from the fault will trip.

Mechanical consistency: Each product adopts dimensional standards simplifying and optimising its use within the system. It shares the same accessories and auxiliaries and complies with global ergonomic choices (utilisation mode, operating mode, setting and configuration devices, tools, etc.) making its installation and operation within the system a simpler process.

Prefabricated and tested solutions, upstream and downstream from the device complying with the IEC 60439-1 switchboard standard.

Communication consistency:
Thanks to the use of standard Web technologies, you can offer your customers intelligent Merlin Gerin switchboards allowing easy access to information: follow-up of currents, voltages, powers, consumption history, etc.

Each product complies with global choices in terms of communication protocols (Modbus, Ethernet, etc.) for simplified integration in the management, supervision and monitoring systems.

Guiding Tools for more efficient design and implementation of your installations.

SM6
Medium voltage switchboard system from 1 to 36 kV

Sepam
Protection relays

Masterpact
Protection switchgear from 100 to 6300 A

Trihal MV/LV dry cast resin transformer from 160 to 5000 kVA

Evolis MV vacuum switchgear and components from 1 to 24 kV.

The Technical guide


These technical guides help you comply with installation standards and rules i.e.: The electrical installation guide, the protection guide, the switchboard implementation guide, the technical booklets and the co-ordination tables all form genuine reference tools for the design of highperformance electrical installations. For example, the LV protection co-ordination guide - discrimination and cascading optimises choice of protection and connection devices while also increasing markedly continuity of supply in the installations.

CAD software and tools


The CAD software and tools enhance productivity and safety. They help you create your installations by simplifying product choice through easy browsing in the Guiding System offers. Last but not least, they optimise use of our products while also complying with standards and proper procedures.

Compact
Protection switchgear system from 100 to 630 A

Multi 9
Modular protection switchgear system up to 125 A

Prisma Plus
Functional system for electrical distribution switchboards up to 3200 A

Pragma Enclosures for distribution switchboards up to 160 A

Canalis Prefabricated Busbar Trunking from 25 to 4000 A

PowerLogic Power management

Training
Training allows you to acquire the Merlin Gerin expertise (installation design, work with power on, etc.) for increased efficiency and a guarantee of improved customer service. The training catalogue includes beginners courses in electrical distribution, knowledge of MV and LV switchgear, operation and maintenance of installations, design of LV installations to give but a few examples.

Circuit protection and control devices

Contents

Multi 9
Multi 9 circuit breakers from 0.5 to 125 A 6

EasyPact
EasyPact circuit breakers from 15 to 250 A 8

Compact NS
Compact NS AC circuit breakers up to 630 A Compact NS AC circuit breakers from 630 to 3200 A Compact NS DC circuit breakers from 100 to 630 A 10 12 14

Masterpact NT and NW
Masterpact NT06 to NT16 AC circuit breakers and switch-disconnectors from 630 to 1600 A Masterpact NW08 to NW63 AC circuit breakers and switch-disconnectors from 800 to 6300 A Masterpact NW10 to NW40 DC circuit breakers from 800 to 6300 A 16 18 20

Micrologic control units


Overview of functions 22

Interpact INS
Interpact INS40 to 160 switch-disconnectors Interpact INS250-100 to 630 switch-disconnectors Interpact INS630b to 2500 switch-disconnectors 24 28 32

Interpact INV
Interpact INV100 to 630 switch-disconnectors Interpact INV630b to 2500 switch-disconnectors 36 40

Fupact
Fupact INFp32 to INFp800 switch-disconnector fuses Fupact ISFT100 to ISFT630 fuse-switch disconnectors Fupact ISFL160 to ISFL630 fuse-switch disconnectors 44 48 52

Vigirex
Protection and monitoring relays 56

Multi 9

Multi 9 circuit breakers from 0.5 to 125 A

056984NR_21

Multi 9 circuit breakers

6 to 32 A
DPNa
1+N In 30 C 40 C 6-32 300 4 230 b 4.5 4.5 100 % b b -

1 to 40 A
DPN N
1+N 1-40 300 4 230 b b 6 6 15 100 % b b -

4 to 40 A
DPN N Vigi
1+N 4-40 300 4 230 b b 6 6 b b integrated 30-300 mA b b b 36 81 70

Number of poles

Electrical characteristics
Rated current (A)

DPN Vigi.

C60.

056738R_29

Rated insulation voltage (V) Ui Impulse withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz Fast closing Disconnection with positive contact indication AC breaking capacity (kA rms) IEC 60947-2 (EN 60947-2) Icu 130 V 240 V 400 V 415 V 440 V 500 V Ics (% of Icu) IEC 60898 Icn 230/400 V Ics 230/400 V DC breaking capacity (kA) IEC 60947-2 (EN 60947-2) Icu 24/48 V 60 V 125 V 125 V 250 V 500 V (% of Icu)

PB100270_16

C120.

Ics

Trip units (non adjustable)


Curve type
056908NR-33

B (lm = 3.2 to 4.8 ln) C (lm = 7 to 10 ln) D (lm = 10 to 14 ln) K (lm = 10 to 14 In) Z (lm = 2.4 to 3.2) MA (lm = 12 ln)

Personal protection Add-on rcd's (Vigi module) Electrical auxiliaries

NG125.

Auxiliary and alarm switches (OF-SD) Shunt trip (MX); undervoltage release (MN)

18 81 70

b b b 18 81 70

Installation
Plug in base Terminal shieds Padlocking device Rotary handle Dimensions (mm)

W H D

Multi 9

6 to 45 A
1+N 6-45 440 4 50-250 b 10 b integrated 10-100 mA b 18 111 73

6 to 40 A
1

0.5 to 63 A
C60N C60H

0.5 to 25 A
C60L
2-3-4 1

32 to 40 A

50 to 63 A

63 to 125 A
C120N

10 to 125 A
C120H

10 to 80 A

4 to 80 A
2-3-4 4-80 690 8 500 b b 100 50 50 40 12 75 % b b 2-3

C60H RCBO C60a

NG125N NG125H NG125L NG125LMA


2-3-4 1 2-3-4 1

2-3-4 1

2-3-4 1

2-3-4 1

2-3-4 1

2-3-4 1

2-3-4 1

2-3-4 1

6-40 500 6 440 b b 10 5 10 3 5 3 5 3 75 % 4.5 4.5 10 (1P) 10 (2P) 20 (3P) 25 (4P) 100 % b b b

63 500 6 440 b b 20 10 20 3 10 3 10 6 75 % 6 6 15 (1P) 20 (2P) 30 (3P) 40 (4P) 100 % b b b b

63 500 6 440 b b 30 15 30 4 15 4 15 10 50 % 10 7.5 20 (1P) 25 (2P) 40 (3P) 50 (4P) 100 % b b b b

y 25 500 6 440 b b 50 25 50 6 25 6 25 20 50 % 25 (1P) 30 (2P) 50 (3P) 60 (4P) 100 % b b b b b b y 40 A b

32-40 500 6 440 b b 50 20 40 5 20 5 20 15 50 % 25 (1P) 30 (2P) 50 (3P) 60 (4P) 100 % b b b b b

50-63 500 6 440 b b 50 15 30 4 15 4 15 10 50 % 25 (1P) 30 (2P) 50 (3P) 60 (4P) 100 % b b b b b

63-125 500 6 440 b b 20 10 20 3 10 3 10 6 75 % 10 7.5 10 (1P) 10 (1P) 10 (2P) 100 % b b b b

10-125 500 6 440 b b 30 15 30 4.5 15 4.5 15 10 50 % 15 7.5 15 (1P) 15 (1P) 15 (2P) 100 % b b b b

10-125 690 8 500 b b 50 25 50 6 25 6 25 20 6 8 75 % 25 (1P) 25 (1P) 25 (2P) 25 (4P) 100 % b b b b

10-80 690 8 500 b b 70 36 70 9 36 9 36 30 6 10 75 % 36 (1P) 36 (1P) 36 (2P) 36 (4P) 100 % b b

10-80 690 8 500 b b 100 50 100 12.5 50 12.5 50 40 6 12 75 % 50 (1P) 50 (1P) 50 (2P) 50 (4P) 100 % b b b b

b b b b b b 18/P 81 73

b b

b b

b b

b b b y 63 A b b b 27/P 81 73

b b

b b b b b 27/P 103 81

b b

b b

b b

EasyPact

EasyPact circuit breakers from 15 to 250 A

EasyPact circuit breakers


DB106891-25

Number of poles Rated current (A)

In

at 40 C

Rated insulation voltage (V) Rated impulse withstand voltage (kV) Rated operational voltage (V)

Ui Uimp Ue

AC 50/60 Hz DC AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P in series) % Icu 110-400 V 415-550 V

Electrical characteristics as per IEC 60947-2 and EN 60947-2


Ultimate breaking capacity (kA rms) EZC100. Icu

PB101210a-27

Rated service breaking capacity Suitability for isolation Utilisation category Pollution degree Endurance (C-O cycles)

Ics

Mechanical Electrical In/415 V Icn AC 50/60 Hz 130 V 220 V 460 V AC 50/60 Hz 240 V 277/480Y V

Electrical characteristics as per JIS C8370


EZC250. Breaking capacity (kA)

Electrical characteristics as per NEMA-AB1


Breaking capacity (kA) Protection Overload protection Instantaneous protection Auxiliaries Indication contacts HIC

Bimetal Magnetic Auxiliary switch Alarm switch Combined AX + AL Shunt trip release Undervoltage release Crimp lugs/bars Box lugs for bare cables Rotary handles Terminal extensions Spreaders Phase barriers Terminal shields Padlocking system DIN rail plate AX AL AXAL SHT UVR

Voltage releases

Installation
Connection Accessories

direct extended

Dimension and weight Dimensions (mm)

W H D

Weight (kg) (1) Only 3 poles. (2) 50 in 2 poles.

EasyPact

EZC100B
3 15, 20, 25, 30, 40, 50, 60 690 6 550 10 10 7.5 7.5 5 2.5 25 % 25 % b A 3 8500 4000 10 10 5 fixed fixed b b b b b b b b b b b b b b 75 130 60 0.78

EZC100F
3 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 690 6 550 250 25 25 10 10 7.5 5 5 5 50 % 50 % b A 3 8500 4000 25 25 7.5 fixed fixed b b b b b b b b b b b b b b 75 130 60 0.78

EZC100N
1 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 690 6 550 250 25 18 2.5 2.5 5 50 % 50 % b A 3 8500 4000 15 10 10 fixed fixed b b b b b b b b b b b b b b 25 130 60 0.28 3 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 690 6 550 250 25 25 18 15 10 5 5 5 50 % 50 % b A 3 8500 4000 25 25 10 25 10 fixed fixed b b b b b b b b b b b b b b 75 130 60 0.78

EZC100H
1 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 690 6 550 250 50 25 5 5 10 50 % 50 % b A 3 8500 4000 30 18 18 fixed fixed b b b b b b b b b b b b b b 25 130 60 0.28 2-3 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 690 6 550 250 100 100 (1) 30 30 20 10 10 10 50 % 25 % b A 3 8500 4000 100 100 25 100 18 (2) fixed fixed b b b b b b b b b b b b b b 60 130 60 0.78

EZC250F
3 100, 125, 150, 160, 175, 200, 225, 250 690 6 550 250 25 25 18 18 15 5 5 5 50 % 50 % b A 3 10000 5000 30 30 15 25 15 fixed fixed b b b b b b b b b b b b b b 105 165 60 1.3

EZC250N
3 100, 125, 150, 160, 175, 200, 225, 250 690 6 550 250 50 50 25 25 20 8 20 20 50 % 50 % b A 3 10000 5000 50 50 25 50 18 fixed fixed b b b b b b b b b b b b b b 105 165 60 1.3

EZC250H
2-3 100, 125, 150, 160, 175, 200, 225, 250 690 6 550 250 85 85 36 36 25 10 30 30 50 % 50 % b A 3 10000 5000 85 85 35 85 25 (1) fixed fixed b b b b b b b b b b b b b b 50 (2), 75 (1) 165 60 1.1

Compact NS

Compact NS AC circuit breakers up to 630 A

PB101050_33

Compact circuit breakers


Number of poles Control manual electric fixed plug-in (on base) withdrawable (on chassis) toggle direct or extended rotary handle front connection rear connection front connection rear connection front connection rear connection 40 C 65 C

Connections

Electrical characteristics as per IEC 60947-2 and EN 60947-2


Compact NS250H.
Rated current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kV) Rated operational voltage (V) Type of circuit breaker Ultimate breaking capacity (kA rms) lcu AC 50/60 Hz 220/240 V 380/415 V 440 V 500 V 525 V 660/690 V In Ui Uimp Ue

PB101044_42

AC 50/60 Hz DC

Service breaking capacity (kA rms) Suitability for isolation Utilisation category Durability (C-O cycles) mechanical electrical

lcs

% Icu

440 V

In/2 In

Electrical characteristics as per NEMA AB1 (H.I.C.)


Breaking capacity (kA) 240 V 480 V 600 V 240 V 480 V 600 V

Electrical characteristics as per UL508


Compact NS630N.
Breaking capacity (kA)

Protection Trip units Overload protection Short-circuit protection Earth-fault protection Zone selective interlocking Add-on earth-leakage protection Current measurements Additional measurement, indication and control auxiliaries Indication contacts MX shunt and MN undervoltage releases Voltage-presence indicator Current-transformer module and ammeter module Insulation-monitoring module Remote communication by bus Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values long time Ir (In x ) short time lsd (Ir x ) instantaneous Ii (In x ) lg (In x ) ZSI add-on Vigi module combination with Vigirex relay

Installation
Accessories terminal extensions and spreaders terminal shields and interphase barriers escutcheons fixed, front connections 2-3P / 4P fixed, front connections 3P / 4P

(1) 2P in 3P case for type N only. (2) Specific trip units are available for operational voltages > 525 V. (3) NS100N et U u 500 V: Ics = 50 % Icu. (4) Operational voltage y 500 V.

Dimensions (mm) W x H x D Weight (kg) Source changeover system

Manual, remote-operated and automatic source changeover systems

10

Compact NS

NS125E
3-4 b b b 125 750 8 500 E 25 16/10 10 6 50 % b A 10000 6000 6000

NS100
2 (1)-3-4 b b b b b b b b b 100 100 750 8 690 500 N SX H 100 70 65 50 35 10 L 150 150 130 100 100 75 85 90 36 50 35 50 25 36 22 35 8 10 100 % (3) b A 50000 50000 30000

NS160
2 (1)-3-4 b b b b b b b b b 160 150 750 8 690 500 N SX H 100 70 65 50 35 10 L 150 150 130 70 50 20 85 90 36 50 35 50 30 36 22 35 8 10 100 % b A 40000 40000 20000

NS250
2 (1)-3-4 b b b b b b b b b 250 220 750 8 690 500 N SX H 100 70 65 50 35 10 L 150 150 130 70 50 20 85 90 36 50 35 50 30 36 22 35 8 10 100 % b A 20000 20000 10000

NS400
3-4 b b b b b b b b b 400 320 750 8 690 500 N 85 50 42 30 22 10 (2) 100 % b A 15000 12000 6000 H 100 70 65 50 35 20 (2) L 150 150 130 100 100 75 (2)

NS630
3-4 b b b b b b b b b 630 500 750 8 690 500 N H L 150 150 130 70 50 35 (2) 85 100 50 70 42 65 30 50 22 35 10 (2) 20 (2) 100 % (4) b A 15000 8000 4000

E
5 5 -

N
85 35 8

SX
90 50 20

H
100 65 35

L
200 130 50

N
85 35 20

SX
90 50 20

H
100 65 35

L
200 130 50

N
85 35 20

SX
90 50 20

H
100 65 35

L
200 130 50

N
85 42 20

H
100 65 35

L
200 130 50

N
85 42 20

H
100 65 35

L
200 130 50

E
non interchangeable 12.5 125 (A) b b b b b b b 105 x 161 x 86 1.8 / 2.3 -

N
85 25 10

SX
85 50 10

H
85 65 10

L
-

N
85 35 10

SX
85 50 10

H
85 65 10

L
-

N
85 35 18

SX
85 50 18

H
85 65 18

L
-

N
-

H
-

L
-

N
-

H
-

L
STR53 (electronic) b b b b b b b b

TM (thermal-magnetic) b b b b b b b b b b b b b b 105 x 161 x 86 / 140 x 161 x 86 2.0 to 2.2 / 2.6 to 2.8 b

STR22 (electronic) b b b b b -

STR23 (electronic) b b b b b b b b b b

b b -

b b b b b 140 x 255 x 110 / 185 x 255 x 110 6.2 to 8.1 b

b b b b b

11

Compact NS

Compact NS AC circuit breakers from 630 to 3200 A

PB101206_39

Compact circuit breakers


Number of poles Control manual electric toggle direct or extended rotary handle

Type of circuit breaker


Connections fixed front connection rear connection front connection with bare cables front connection rear connection 50 C 65 C (1)

withdrawable (on chassis)

Electrical characteristics as per IEC 60947-2 and EN 60947-2


Rated current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kV) Rated operational voltage (V) Type of circuit breaker Ultimate breaking capacity (kA rms)
E45178R_68

In Ui Uimp Ue

Compact NS1600H.

AC 50/60 Hz DC 220/240 V 380/415 V 440 V 500/525 V 660/690 V DC 250 V 500 V Value or % Icu manual operation electrical operation 0.5 s 1s 3s kA peak 10 % AC 50/60 Hz

lcu

Service breaking capacity (kA rms) Short-time withstand current (kA rms) V AC 50/60 Hz V AC 50/60 Hz Integrated instantaneous protection Suitability for isolation Utilisation category Durability (C-O cycles) mechanical electrical

lcs lcw

440 V 690 V

Compact NS2000H.
Pollution degree

In/2 In In/2 In

Electrical characteristics as per Nema AB1


Breaking capacity at 60 Hz (kA) 240 V 480 V 600 V

Protection and measurements Interchangeable control units Overload protection Short-circuit protection

Earth-fault protection Residual earth-leakage protection Zone selective interlocking Protection of the fourth pole Current measurements Remote communication by bus Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values Additional indication and control auxiliaries Indication contacts Voltage releases MX shunt release MN undervoltage release

long time Ir (In x ) short time Isd (Ir x ) instantaneous Ii (In x ) lg (In x ) In ZSI

Installation
terminal extensions and spreaders terminal shields and interphase barriers escutcheons Dimensions fixed devices, front connections (mm) 3P HxWxD 4P Weight fixed devices, front connections (kg) 3P 4P Accessories

(1) 65 C with vertical connections. See the temperature derating tables for other types of connections. (2) Ics: 100 % Icu for breaking capacity 440V/500V/660V Ics: 75 % Icu for breaking capacity 220V/380V.

Source changeover system


Manual, remote-operated and automatic source changeover systems

12

Compact NS

NS630b NS800
3-4 b b b

NS1000

NS1250 NS1600
3-4 b b b 3-4 b b b

NS1600b NS2000 NS2500 NS3200


3-4 b -

N
b b b b b 630 630 750 8 690 500 N 50 50 50 40 30 100 % 75 % 25 17 55 b B 10000 6000 5000 4000 2000 III

H
b b b b b

L
b b b b 800 800 1000 1000

N
b b b b b 1250 1250 750 8 690 500 N 50 50 50 40 30 100 % 75 % 25 17 55 b B 10000 5000 4000 3000 2000 III

H
b b b b b

N
b b b b 1600 1510 750 8 690 500

H
b b b b

N
b 1600 1550 750 8 690 500

H
b 2000 1900 2500 2500 3200 2970

H 70 70 65 50 42 75 % 50 % 25 17 -

L 150 150 130 100 25 100 % 100 % 10 7 -

H 70 70 65 50 42 75 % 50 % 25 17 -

B 6000 5000 4000 2000

A 4000 3000 3000 2000

N 50 50 50 40 30 75 % 75 % 25 17 55 b B 10000 5000 2000 2000 1000 III

H 70 70 65 50 42 50 % 50 % 25 17 -

N 85 70 65 65 65 100 % (2) 100 % (2) 32 130 b B 5000 3000 2000 2000 1000 III

H 125 85 85 75 % 75 % 32 130 B

N
50 35 25

H
65 50 50

L
125 100 Micrologic 5.0 b b b b b b -

N
50 35 25

H
65 50 50

N
50 35 25

H
65 50 50

N
85 65 50 Micrologic 5.0 A b b b b b b b b b b b b b b

H
125 85 Micrologic 6.0 A b b b b b b b b b b b Micrologic 7.0 A b b b b b b b b b b b

Micrologic 2.0 b b b b b b b b b b b 327 x 210 x 147 327 x 280 x 147 14 18 b

Micrologic 2.0 A b b b b b b b b b b

b b 350 x 420 x 160 350 x 535 x 160 24 36 -

13

Compact NS

Compact NS DC circuit breakers from 100 to 630 A

Compact circuit breakers


PB101047a-14

Number of poles

Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2


Rated current at 40 C Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Type of circuit breaker Ultimate breaking capacity (L/R = 5 ms and L/R = 15 ms) In Ui Uimp Ue Icu (A) (V) (kV peak) (V DC) (kA rms) V DC 48-125 V (1P) (1) 250 V (1P) (1) 500 V (2P) (1) 750 V (3P) (1)

Service breaking capacity Ics % Icu Rated making capacity Icm % Icu Utilisation category Breaking time (ms) Suitability for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Interchangeable Protection Overloads Short-circuits Durability (O/F cycles) Mechanical Electrical 250 V In 250 V In/2 500 V In 500 V In/2 750 V In 750 V In/2 Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release

PB101055a-27

PB101048a-20

Installation and connections


Fixed
PB100905a-36

Plug-in (base) Withdrawable (chassis) Dimensions and weight Dimensions H x W x D (mm) connected in series

Front connection Rear connection Front connection Rear connection Front connection Rear connection Fixed 1P 2P 3P 4P 1P 2P 3P 4P

Weight (kg) connected in series

Fixed

(1) Number of poles taking part in current interruption. Example. The NS100N circuit breaker exists in the following versions: - 1 pole with an Icu of 50 kA, for systems y 250 V - 2 poles with an Icu of 85 kA, for systems y 500 V; 1 pole can be used in a 250 V system.

14

Compact NS

NS100
1 100 800 8 250 N 50 50 100 % 100 % A < 10 ms b III b b b 10000 5000 10000 5000 10000 5000 10000 b b b b b 2 3-4

NS160
1 160 800 8 250 N 50 50 2 3-4

NS250 NS400 NS630


3-4 250 800 8 750 DC 100 100 100 100 3-4 400 800 8 750 DC 100 100 100 100 3-4 550 800 8 750 DC 100 100 100 100

H 85 85 -

500 N 85 85 85 -

H 100 100 100 -

750 DC 100 100 100 100

H 85 85 -

500 N 85 85 85 -

H 100 100 100 -

750 DC 100 100 100 100

b b b

b b b

b b b

b b b

b b b

b b b

b b b

b b b

b b b

b b

b b 5000 1000 2000 1000 2000 1000 2000

b b

b b b b 161 x 105 x 86 161 x 140 x 86 1.6 to 1.9 2.1 to 2.3

b b b b

b b b b

b b b b

b b b b

161 x 35 x 86 0.7 -

161 x 70 x 86 1.2 -

161 x 35 x 86 0.7 -

161 x 70 x 86 1.2 -

161 x 105 x 86 161 x 140 x 86 1.6 to 1.9 2.1 to 2.3

255 x 140 x 110 225 x 185 x 110 6.0 7.8

15

Masterpact NT and NW

Masterpact NT06 to NT16


AC circuit breakers and switch-disconnectors from 630 to 1600 A
0

Common characteristics
PB100767a-48

Number of poles Rated insulation voltage (V) Impulse withstand voltage (kV) Rated operational voltage (V AC 50/60 Hz) Suitability for isolation Degree of pollution

Ui Uimp Ue IEC 60947-2 IEC 60664-1

3-4 1000 12 690/1000 3

Circuit-breaker characteristics as per IEC 60947-2


Rated current (A) Rating of 4th pole (A) Sensor ratings (A) Type of circuit breaker Ultimate breaking capacity (kA rms) V AC 50/60 Hz In at 40 C/50 C (1)

Icu

Rated service breaking capacity (kA rms) Utilisation category Rated short-time withstand current (kA rms) V AC 50/60 Hz Integrated instantaneous protection (kA peak 10 %) Rated making capacity (kA peak) V AC 50/60 Hz

Ics Icw

220/415 V 440 V 525 V 690 V 1000 V % Icu 0.5 s 1s 3s 220/415 V 440 V 525 V 690 V 1000 V

Icm

Break time (ms) between tripping order and arc extinction Closing time (ms)

Circuit-breaker characteristics as per NEMA AB1


Breaking capacity (kA) V AC 50/60 Hz 240 V 480 V 600 V

Switch-disconnector characteristics as per IEC 60947-3 and Annex A


Type of switch-disconnector Rated making capacity (kA peak) AC23A/AC3 category V AC 50/60 Hz Icm 220 V 440 V 525/690 V 1000 V 0.5 s 1s 3s 690 V

Rated short-time withstand current (kA rms) AC23A/AC3 category V AC 50/60 Hz

Icw

Ultimate breaking capacity Icu (kA rms) with an external protection relay Maximum time delay: 350 ms Service life Mechanical C/O cycles x 1000 Type of circuit breaker Rated current C/O cycles x 1000 Electrical IEC 60947-2 with maintenance without maintenance In (A) without maintenance

Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie

440 V (4) 690 V 1000 V AC23A 440 V (4) 690V AC3 (5) 380/415 V (kW) 440 V (kW) 440 V (4) 690 V

(1) 50 C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) SELLIM system. (4) Available for 480 V NEMA. (5) Suitable for motor control (direct-on-line starting).

Type of circuit breaker or switch-disconnector Rated operationnal current Ie (A) C/O cycles x 1000 Electrical without maintenance IEC 60947-3 Type of circuit breaker or switch-disconnector Rated operationnal current Ie (A) Motor power C/O cycles x 1000 Electrical IEC 60947-3 Annex M/IEC 60947-4-1 without maintenance

16

Masterpact NT and NW

Sensor selection
Sensor rating (A) 250 (1) Ir threshold setting(A) 100 to 250 (1) For NT02 rating, please consult us. 400 160 to 400 630 250 to 630 800 320 to 800 1000 400 to 1000 1250 500 to 1250 1600 640 to 1600

NT06
630 630 400 to 630 H1 H2 42 50 42 50 42 42 42 42 100 % B B 42 36 42 36 24 20 90 88 105 88 105 88 88 88 88 25 25 < 50 42 42 42 50 50 42

NT08
800 800 400 to 800 L1 (2) 150 130 100 25 A 10 10 x In (3) 330 286 220 52 9 H10 20 B 20 20 42 -

NT10
1000 1000 400 to 1000

NT12
1250 1250 630 to 1250 H1 H2 42 50 42 50 42 42 42 42 100 % B B 42 36 36 24 20 90 88 105 88 105 88 88 88 88 25 25 < 50 42 42 42 50 50 42

NT16
1600 1600 800 to 1600 H10 20 B 20 20 42 -

150 100 25

HA 75 75 75 36 36 20 36

HA10 42 20 20 20

HA 75 75 75 36 36 20 36

HA10 42 20 20 20

25 12.5 H1 H2 630 6 6 3 3 H1/H2/HA 630 6 3 H1/H2/HA 500 y 250 y 300 6 -

L1 3 2 -

H10 0.5

H1 800 6 3 800 6 3

H2 6 3 -

L1 3 2 -

H10 0.5

H1 1000 6 3 1000 6 3

H2 6 3 -

L1 3 2 -

H10 0.5

H1 1250 6 3 1250 6 3

H2 6 3 -

H10 0.5

H10 1600 0.5 1600 6 3

H1 6 3 -

H2 6 3 -

630 250 to 335 300 to 400

800 335 to 450 400 to 500

1000 450 to 560 500 to 630

1000 450 to 560 500 to 630

17

Masterpact NT and NW

Masterpact NW08 to NW63


AC circuit breakers and switch-disconnectors from 800 to 6300 A

Common characteristics
PB100768a-38

Number of poles Rated insulation voltage (V) Impulse withstand voltage (kV) Rated operational voltage (V AC 50/60 Hz) Suitability for isolation Degree of pollution

Ui Uimp Ue IEC 60947-2 IEC 60664-1

3-4 1000/1250 12 690/1150 4 (1000 V) / 3 (1250 V)

Circuit-breaker characteristics as per IEC 60947-2


Rated current (A) Rating of 4th pole (A) Sensor ratings (A) Type of circuit breaker Ultimate breaking capacity (kA rms) V AC 50/60 Hz at 40 C / 50 C (1)

PB100769a-70

Icu

Rated service breaking capacity (kA rms) Utilisation category Rated short-time withstand current (kA rms) V AC 50/60 Hz Integrated instantaneous protection (kA peak 10 %) Rated making capacity (kA peak) V AC 50/60 Hz

Ics Icw

220/415/440 V 525 V 690 V 1150 V % Icu 1s 3s 220/415/440 V 525 V 690 V 1150 V

Icm

Break time (ms) between tripping order and arc extinction Closing time (ms)

Circuit-breaker characteristics as per NEMA AB1


Breaking capacity (kA) V AC 50/60 Hz Type of circuit breaker Ultimate breaking capacity (kA rms) V AC 50/60 Hz Rated service breaking capacity (kA rms) Rated short-time withstand current (kA rms) 240/480 V 600 V

Unprotected circuit-breaker characteristics: tripping by shunt trip as per IEC 60947-2


Icu Ics Icw 220...690 V % Icu 1s 3s

Overload and short-circuit protection with external protection relay: short-circuit protection, maximum delay: 350 ms (4) Rated making capacity (kA peak) V AC 50/60 Hz Icm 220...690 V

Switch-disconnector characteristics as per IEC 60947-3 and Annex A


Type of switch-disconnector Rated making capacity (kA peak) AC23A/AC3 category V AC 50/60 Hz Rated short-time withstand current (kA rms) AC23A/AC3 category V AC 50/60 Hz Icm Icw 220...690 V 1150 V 0.5 s 1s 3s

Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie


Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Type of circuit breaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance IEC 60947-2 Type of circuit breaker or switch-disconnector Rated operational current Ie (A) C/O cycles x 1000 Electrical without maintenance IEC 60947-3 Type of circuit breaker or switch-disconnector Rated operational current Ie (A) Motor power

440 V (5) 690 V 1150 V AC23A 440 V (5) 690 V AC3 (6) 380/415 V (kW) 440 V (5) (kW) 690 V (kW) 440/690 V (5)

(1) 50 C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) Equipped with a trip unit with a making current of 90 kA peak. (4) External protection must comply with permissible thermal constraints of the circuit breaker (please consult us). No fault-trip indication by the SDE or the reset button. (5) Available for 480 V NEMA. (6) Suitable for motor control (direct-on-line starting).

C/O cycles x 1000 Electrical IEC 60947-3 Annex M/IEC 60947-4-1

without maintenance

18

Masterpact NT and NW

Sensor selection
250 (1) 100 to 250 (1) For NW02 rating, please consult us. Sensor rating (A) Ir threshold setting(A) 400 160 to 400 630 250 to 630 800 320 to 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 400 500 630 800 1000 1250 1600 2000 2500 to 1000 to 1250 to 1600 to 2000 to 2500 to 3200 to 4000 to 5000 to 6300

NW08 NW10 NW12 NW16


800 800 400 to 800 N1 42 42 42 100 % B 42 22 Without 88 88 88 25 < 70 42 42 1000 1000 400 to 1000 H1 65 65 65 1250 1250 630 to 1250 H2 100 85 85 1600 1600 800 to 1600 L1 (2) 150 130 100 H10 50

NW20
2000 2000 1000 to 2000 H2 100 85 85 H3 150 130 100 L1 (2) 150 130 100 -

NW25
2500 2500 1250 to 2500 H10 H1 65 65 65 50 100 % B 50 65 50 65 Without Without 143 143 143 105 25 25 < 70 65 65 HA 55 100 % 55 55 Without 121

NW32
3200 3200 1600 to 3200 H2 100 85 85 -

NW40
4000 4000 2000 to 4000 H3 150 130 100 -

NW40b
4000 4000 2000 to 4000 H10 H1 100 100 100 50 100 % B 50 100 50 100 Without Without 220 220 220 105 25 25 < 80 100 100 HA 85 100 % 85 85 Without 187

NW50
5000 5000 2500 to 5000 H2 150 130 100 -

NW63
6300 6300 3200 to 6300

65 36 Without 143 143 143 25

85 50 190 220 187 187 25

30 30 80 330 286 220 10

H1 65 65 65 100 % B 50 65 50 36 Without Without 143 143 143 105 25 25 < 70 65 65 HA 50 100 % 50 36 Without 105

85 75 190 220 187 187 25

65 65 150 330 286 220 25

30 30 80 330 286 220 10

85 75 190 220 187 187 25

65 65 150 330 286 220 25

100 100 270 330 286 220 25

65 65 HA 50

100 85 HF (3) 85

150 100

100 85 HF (3) 85 85 75 Without 187

150 100

150 100

100 85 HF (3) 85 85 75 Without 187

150 100

150 100

100 % 50 85 36 50 Without Without 105 187

NW08 / NW10 / NW12


NA 88 42 HA 105 50 36 HF 187 85 50 HA10 105 50 50

NW16
HA 105 50 50 HF 187 85 50 HA10 105 50 50

NW20
HA 105 50 50 HF 187 85 50 HA10 105 50 50

NW25 / NW32 / NW40 NW40b / NW50 / NW63


HA 121 55 55 HF 187 85 75 HA10 105 50 50 HA 187 85 85 10 5 H1 H2 4000b/5000/6300 1.5 1.5 1.5 1.5 H1/H2/HA 4000b/5000/6300 1.5 1.5

25 12.5 N1/H1/H2 L1 800/1000/1250/1600 10 3 10 3 H1/H2/NA/HA/HF 800/1000/1250/1600 10 10 H1/H2/HA/HF 800 1000 335 to 450 450 to 560 400 to 500 500 to 630 800 to 1000 y 800 6

H10 0.5

1250 560 to 670 500 to 800 1000 to 1250

1600 670 to 900 800 to 1000 1250 to 1600

20 10 H1/H2 L1 H10 2000 8 3 6 3 0.5 H1/H2/H3/HA/HF 2000 8 6 H1/H2/H3/HA/HF 2000 900 to 1150 1000 to 1300 1600 to 2000

H1/H2 H3 2500/3200/4000 5 1.25 2.5 1.25 2500/3200/4000 5 2.5

H10 0.5

19

Masterpact NT and NW

Masterpact NW10 to NW40 DC circuit breakers from 800 to 6300 A

Masterpact circuit breakers


E88193a-31

Number of poles

Version C or D Version E In Ui Uimp Ue L/R = 5 ms Icu (A) (V) (kV peak) (V DC) (kA) V DC 500 750 900 500 750 900 500 750 900

Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2


Rated current at 40 C / 50 C (1) Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Type of circuit breaker Ultimate breaking capacity

PB101129a-34

L/R = 15 ms

Icu

L/R = 30 ms

Icu

NW10DC 4P.

Service breaking capacity Ics % Icu Rated making capacity Icm % Icu Short-time withstand current Icw 1s Utilisation category Breaking time (ms) Making time (ms) Suitability for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Protection Overloads Short-circuits Durability (O/F cycles) Mechanical With maintenance Without maintenance Electrical Without maintenance 500 V CC 900 V CC Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release

Characteristics of switch-disconnectors as per IEC 60947-3 and EN 60947-3


Type of switch-disconnector Rated making capacity Rated short-time withstand current Icm Icw Drawout Fixed Dimensions and weight Dimensions H x W x D (mm) connected in series 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P % Icu 1s RC RC Horizontal Vertical Horizontal Vertical

Installation and connections


Connection

Drawout Fixed

Weight (kg) connected in series (approximate values)

Drawout Fixed

(1) 50 C - see the derating table for the NW40.

20

Masterpact NT and NW

NW10
3 4 1000 1000 12 500/900 N 85 35 25 100 % 100 % 50 B 30 to 75 < 70 b 4 b b 20000 10000 8500 b b b

NW20
3 4 2000 2000 12 500/900 N 85 35 25 -

NW40
3 4 4000 4000 12 500/900 N 85 35 25 -

H 100 85 85 85 50 35 50 50 25

H 100 85 85 85 50 35 50 50 25

H 100 85 85 85 50 35 50 50 25

85

50

85

50

85

b b

b b

b b

b b

b b

2000 b b b HA 85 85 b b b b

5000 b b b

2000 b b b HA 85 85 b b b b

2000 b b b

1000 b b b HA 85 85 b b

b b b b 439 x 441 x 494 439 x 556 x 494 352 x 422 x 427 352 x 537 x 427 90 to 116 125 to 146 60 to 86 85 to 106

b b b b

b b 439 x 441 x 594 439 x 556 x 594 352 x 422 x 527 352 x 537 x 527

21

Micrologic control units

Overview of functions

All Masterpact and Compact NS630b up to 3200 A are equipped with a Micrologic control unit that can be changed on site. Control units are designed to protect Power circuits and loads. Alarms may be programmed for remote indications. Measurements of current, voltage, frequency, power and power quality optimise continuity of service and energy management.

Dependability
Integration of protection functions in an ASIC electronic component used in all Micrologic control units guarantees a high degree of reliability and immunity to conducted or radiated disturbances. On Micrologic A, P and H control units, advanced functions are managed by an independent microprocessor.
Note: in the event of Masterpact circuit breaker DC, there is a version Micrologic 1.0 DC. For more information, consult the "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" catalogue - ABTED205160EN.

Micrologic name codes

Current protection
Micrologic 2: basic protection
Protection: long time + instantaneous

2.0 A
X: type of protection b 2 for basic protection b 5 for selective protection b 6 for selective + earth-fault protection b 7 for selective + earth-leakage protection. Y: control-unit generation Identification of the control-unit generation. "0" signifies the first generation. Z: type of measurement b A for "ammeter" b P for "power meter" b H for "harmonic meter".
DB101116

Micrologic 5: basic protection


Protection: long time + short time + instantaneous

PB100772a-32

DB101117

Micrologic 6: selective + earth-fault protection


Protection: long time + short time + instantaneous + earth fault

DB101117

Micrologic 7: selective + earth-leakage protection


Protection: long time + short time + instantaneous + earth leakage

DB101117

22

DB101119

DB101118

Micrologic control units

Measurements and programmable protection


A: ammeter b I1, I2, I3, IN, Iearth-fault, Iearth-leakage and maximeter for these measurements b fault indications b settings in amperes and in seconds. P: A + power meter + programmable protection b measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power factor and maximeters and minimeters b IDMTL long-time protection, minimum and maximum voltage and frequency, voltage and current imbalance, phase sequence, reverse power b load shedding and reconnection depending on power or current b measurements of interrupted currents, differentiated fault indications, maintenance indications, event histories and time-stamping, etc. H: P + harmonics b power quality: fundamentals, distortion, amplitude and phase of harmonics up to the 31st order b waveform capture after fault, alarm or on request b enhanced alarm programming: thresholds and actions.

2.0 A
DB101120

5.0 A
DB101121

5.0 P
DB101122

5.0 H
DB101122

6.0 A
DB101123

6.0 P
DB101124

6.0 H
DB101124

7.0 A
DB101123

7.0 P
DB101124

7.0 H
DB101124

23

Interpact INS

Interpact INS40 to 160 switch-disconnectors

Interpact INS switch-disconnectors


052164a-38

Number of poles

Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3


Conventional thermal current (A) Conventional thermal current in enclosure Rated insulation level (V) Impulse-withstand voltage (kV) Rated operational voltage (V) Interpact INS80 switch-disconnector. Ith Ithe Ui Uimp Ue at 60 C at 60 C AC 50/60 Hz AC 50/60 Hz DC AC 50/60 Hz Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Uninterrupted duty Intermittent duty Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) 1s 3s 20 s 30 s Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440 V 500 V 690 V Electrical DC 250 V

Rated operational voltage AC20 and DC20 (V) Rated operational current (A) Ie

052168a-50

Rated operational power AC23 (kW)

Interpact INS160 switch-disconnector.

Rated duties
059202a-50

Short-circuit making capacity (kA peak)

Icm

Short-time withstand current (A rms)

Icw

Suitability for isolation Durability (category A) (O - C-O cycles) Interpact INS160 emergency-off switch-disconnector.

Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution

Upstream protection
See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA.

24

Interpact INS

INS40
3-4 40 40 690 8 500 250 690 AC22A 40 40 40 40 DC22A 40 40

INS63
3-4 63 63 690 8 500 250 690 AC22A 63 63 63 63 DC22A 63 63

INS80
3-4 80 80 690 8 500 250 690 AC22A 80 80 80 80 DC22A 80 80

INS100
3-4 100 100 750 8 690 250 750 AC22A 100 100 100 100 100 DC22A 100 100

INS125
3-4 125 125 750 8 690 250 750 AC22A 125 125 125 125 125 DC22A 125 125

INS160
3-4 160 160 750 8 690 250 750 AC22A 160 160 160 160 160 DC22A 160 160

AC23A 40 40 40 32 DC23A 40 40

AC23A 63 63 63 40 DC23A 63 63

AC23A 80 72 63 40 DC23A 80 80

AC23A 100 100 100 100 63 DC23A 100 100

AC23A 125 125 125 125 80 DC23A 125 125

AC23A 160 160 160 160 100 DC23A 160 160

11 7,5 20 22 22 18,5 b class 120 - 60 % 15 75 3000 1730 670 550 b 20000 AC22A 1500 1500 1500 1500 DC22A 1500 b b III -

15 15 30 30 30 22 b class 120 - 60 % 15 75 3000 1730 670 550 b 20000 AC22A 1500 1500 1500 1500 DC22A 1500 b b III -

22 15 37 37 30 22 b class 120 - 60 % 15 75 3000 1730 670 550 b 20000 AC22A 1500 1500 1500 1500 DC22A 1500 b b III -

22 22 45 55 55 55 55 b class 120 - 60 % 20 154 5500 3175 1230 1000 b 15000 AC22A 1500 1500 1500 1500 1500 DC22A 1500 b b III -

37 37 55 55 75 75 75 b class 120 - 60 % 20 154 5500 3175 1230 1000 b 15000 AC22A 1500 1500 1500 1500 1500 DC22A 1500 b b III -

45 45 75 90 90 110 90 b class 120 - 60 % 20 154 5500 3175 1230 1000 b 15000 AC22A 1500 1500 1500 1500 1500 DC22A 1500 b b III -

AC23A 1500 1500 1500 1500 DC23A 1500

AC23A 1500 1500 1500 1500 DC23A 1500

AC23A 1500 1500 1500 1500 DC23A 1500

AC23A 1500 1500 1500 1500 1500 DC23A 1500

AC23A 1500 1500 1500 1500 1500 DC23A 1500

AC23A 1500 1500 1500 1500 1500 DC23A 1500

25

Interpact INS

Interpact INS40 to 160 switch-disconnectors

Interpact INS switch-disconnectors


Installation
Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate

Connection
By cables By cables with lugs To bare cable connectors Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Directly to terminals To spreaders To vertical-connection adapters

Flat-facing bars Edgewise bars Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module

Indication and measurement auxiliaries

Control, locking and interlocking


Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle By keylock By padlocks By keylock Mechanical

Locking Interlocking

Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle)

Installation and connection accessories


Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm)

Dimensions and weights


Overall dimensions H x W x D (mm) Approximate weight (kg) 3 poles 4 poles 3 poles 4 poles H x W x D (mm)
DB105413

Enclosure dimensions for Ithe

26

Interpact INS

INS40
b b b b b b b b b b b 0.7 < Nm < 1.3 b b b b 8 85 x 90 x 62.5 85 x 90 x 62.5 0.5 0.6 190 x 115 x 55

INS63
b b b b b b b b b b b 0.7 < Nm < 1.3 b b b b 8 85 x 90 x 62.5 85 x 90 x 62.5 0.5 0.6 190 x 115 x 55

INS80
b b b b b b b b b b b 0.7 < Nm < 1.3 b b b b 8 85 x 90 x 62.5 85 x 90 x 62.5 0.5 0.6 190 x 115 x 55

INS100
b b b b b b b b b b b b b b 1.4 < Nm < 2 b b b b 8 100 x 135 x 62.5 100 x 135 x 62.5 0.8 0.9 260 x 160 x 55

INS125
b b b b b b b b b b b b b b 1.4 < Nm < 2 b b b b 8 100 x 135 x 62.5 100 x 135 x 62.5 0.8 0.9 260 x 160 x 55

INS160
b b b b b b b b b b b b b b 1.4 < Nm < 2 b b b b 8 100 x 135 x 62.5 100 x 135 x 62.5 0.8 0.9 260 x 160 x 55

27

Interpact INS

Interpact INS250-100 to 630 switch-disconnectors

Interpact INS switch-disconnectors


056648a-41

Number of poles

Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3


Conventional thermal current (A) Conventional thermal current in enclosure Rated insulation level (V) Impulse-withstand voltage (kV) Rated operational voltage (V) Ith Ithe Ui Uimp Ue at 60 C at 60 C AC 50/60 Hz AC 50/60 Hz DC AC 50/60 Hz Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Uninterrupted duty Intermittent duty Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) 1s 3s 20 s 30 s Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V

Rated operational voltage AC20 and DC20 (V) Rated operational current (A) Ie Interpact INS250 switch-disconnector.

056652a-41

Rated operational power AC23 (kW)

Interpact INS250 emergency-off switch-disconnector.

Rated duties Short-circuit making capacity (kA peak) Icm

059487a-49

Short-time withstand current (A rms)

Icw

Suitability for isolation Durability (category A) (O - C-O cycles)

Interpact INS400 switch-disconnector.

Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution

Upstream protection
See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) 550 A (DC).
059488a-49

Interpact INS400 emergency-off switch-disconnector.

28

Interpact INS

INS250-100 INS250-160 INS250-200 INS250


3-4 100 100 750 8 690 250 750 AC22A 100 100 100 100 100 DC22A 100 100 3-4 160 160 750 8 690 250 750 AC23A AC22A 100 160 100 160 100 160 100 160 100 160 DC23A DC22A 100 160 100 160 3-4 200 200 750 8 690 250 750 AC23A AC22A 160 200 160 200 160 200 160 200 160 200 DC23A DC22A 160 200 160 200 3-4 250 250 750 8 690 250 750 AC23A AC22A 200 250 200 250 200 250 200 250 200 250 DC23A DC22A 200 250 200 250

INS320
3-4

INS400
3-4

INS500
3-4

INS630
3-4

320 320 750 8 690 250 750 AC23A AC22A 250 320 250 320 250 320 250 320 250 320 DC23A DC22A 250 320 250 320

400 400 750 8 690 250 750 AC23A AC22A 320 400 320 400 320 400 320 400 320 400 DC23A DC22A 320 400 320 400

500 500 750 8 690 250 750 AC23A AC22A 400 500 400 500 400 500 400 500 400 500 DC23A DC22A 400 500 400 500

630 630 (2) 750 8 690 250 750 AC23A AC22A 500 630 500 630 500 630 500 630 500 630 DC23A DC22A 500 550 500 550

AC23A 630 630 630 630 630 DC23A DC23B 550 630 550 630

22 22 45 55 55 55 55 b class 120 - 60 % 30 330 8500 4900 2200 1800 b 15000 AC22A 1500 1500 1500 DC22A 1500 b b III -

45 45 75 90 90 110 90 b class 120 - 60 % 30 330

55 55 90 110 110 132 160 b class 120 - 60 % 30 330

75 75 132 150 150 160 210 b class 120 - 60 % 30 330

90 90 160 185 185 220 250 b class 120 - 60 % 50 330

110 110 200 220 220 250 400 b class 120 - 60 % 50 330

132 150 250 250 250 355 500 b class 120 - 60 % 50 330

200 200 315 400 375 400 560 b class 120 - 60 % 50 330

8500 4900 2200 1800 b 15000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23A DC22A 1500 1500 b b III -

8500 4900 2200 1800 b 15000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23A DC22A 1500 1500 b b III -

8500 4900 2200 1800 b 15000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23A DC22A 1500 1500 b b III -

20000 11500 4900 4000 b 10000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23A DC23A 1500 1000 b b III -

20000 11500 4900 4000 b 10000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23B DC23A 1000 b b III -

20000 11500 4900 4000 b 10000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23B DC23A 1000 b b III -

20000 11500 4900 4000 b 10000 AC23A AC22A 1500 1500 1500 1500 1500 1500 DC23B DC23A 1000 b b III -

AC23A 1500 1500 1500 DC23B 200

29

Interpact INS

Interpact INS250-100 to 630 switch-disconnectors

Interpact INS switch-disconnectors


Installation
Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate

Connection
By cables By cables with lugs To bare cable connectors Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Directly to terminals To spreaders To vertical-connection adapters

Flat-facing bars Edgewise bars Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module

Indication and measurement auxiliaries

Control, locking and interlocking


Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle By keylock By padlocks By keylock Mechanical

Locking Interlocking

Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle)

Installation and connection accessories


Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm)

Dimensions and weights


Overall dimensions H x W x D (mm) Approximate weight (kg) 3 poles 4 poles 3 poles 4 poles H x W x D (mm)
DB105413

Enclosure dimensions for Ithe

30

Interpact INS

INS250-100 INS250-160 INS250-200 INS250


b b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200 b b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200 b b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200 b b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200

INS320
b b b b b b b b b b b b b b b b b b b b 13.5 < Nm < 16.5 b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INS400
b b b b b b b b b b b b b b b b b b b b 13.5 < Nm < 16.5 b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INS500
b b b b b b b b b b b b b b b b b b b b 13.5 < Nm < 16.5 b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INS630
b b b b b b b b b b b b b b b b b b b b 13.5 < Nm < 16.5 b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

31

Interpact INS

Interpact INS630b to 2500 switch-disconnectors

Interpact INS switch-disconnectors


PB100016a-55

Number of poles

Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3


Conventional thermal current (A) Conventional thermal current in enclosure Rated insulation level (V) Impulse-withstand voltage (kV) Rated operational voltage (V) Ith Ithe Ui Uimp Ue at 60 C at 60 C AC 50/60 Hz AC 50/60 Hz DC AC 50/60 Hz Electrical AC 50/60 Hz 220-240 V Interpact INS1600 switch-disconnector. 380-415 V 440-480 V (1)

Rated operational voltage AC20 and DC20 (V) Rated operational current (A) Ie

PB100018a-55

500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Uninterrupted duty Intermittent duty Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) 0.5 s 0.8 s 1s 3s 20 s 30 s Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Interpact INS2500 switch-disconnector. Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution

Rated operational power AC23 (kW)

Interpact INS1600 emergency-off switch-disconnector.

Rated duties Short-circuit making capacity (kA peak) Icm

PB100020a-65

Short-time withstand current (A rms)

Icw

Suitability for isolation Durability (category B) (O - C-O cycles)

Upstream protection
See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) For vertical connection busbars only. For horizontal connection busbars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue.

32

Interpact INS

INS630b
3-4 630 630 1000 12 690 750 800 AC21A AC22A AC23A

INS800
3-4 800 800 1000 12 690 750 800 AC21A AC22A AC23A

INS1000
3-4 1000 1000 1000 12 690 750 800 AC21A AC22A AC23A

INS1250
3-4 1250 1250 1000 12 690 750 800 AC21A AC22A AC23A

INS1600
3-4

INS2000
3-4 2000 2000 1000 12 690 750 800 AC23A AC21B AC22B AC23B 1250 1250 1250 1250 1250 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 -

INS2500
3-4 2500 2500 1000 12 690 750 800 AC21B AC22B AC23B 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 -

1600 (2) 1600 (2) 1000 12 690 750 800 AC21B AC22B AC21A AC22A 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1450 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1450 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 250 400 500 560 710 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 5000 AC21A AC22A AC23A 250 400 500 560 710 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A 315 560 630 710 900 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A 400 710 800 900 b class 120 - 60 % 75 75 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A

DC23A DC21B DC22B DC23B DC21B DC22B DC23B 1600/2 2000/2 2000/2 2500/2 2500/2 1600/4 2000/4 2000/4 2500/4 2500/4 b class 120 - 60 % 105 105 b class 120 - 60 % 105 105 50 50 50 30 13 11 b 500 AC21B AC22B AC23B 100 100 100 100 100 100 100 100 100 100 -

400 710 800 900 b class 120 - 60 % 75 75

50 42 35 20 10 8 b 3000 AC21B AC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 b b b b b b b b b b III III III III III -

50 50 50 30 13 11 b 500 AC22B AC23B AC21B AC22B AC23B AC22A 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 DC22A DC23B DC21B DC22B DC23B 500 500 100 100 500 500 100 100 b III -

DC21B DC22B DC23B 100 100 100 100 b III -

33

Interpact INS

Interpact INS630b to 2500 switch-disconnectors

Interpact INS switch-disconnectors


Installation
Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate

Connection
By cables By cables with lugs To bare cable connectors Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Directly to terminals To spreaders To vertical-connection adapters

Flat-facing bars Edgewise bars Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module

Indication and measurement auxiliaries

Control, locking and interlocking


Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle By keylock By padlocks By keylock Mechanical

Locking Interlocking

Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle)

Installation and connection accessories


Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm)

Dimensions and weights


Overall dimensions H x W x D (mm) Approximate weight (kg) 3 poles 4 poles 3 poles 4 poles H x W x D (mm)
DB105413

Enclosure dimensions for Ithe

34

Interpact INS

INS630b
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 410 x 146.5 14 18 -

INS800
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 410 x 146.5 14 18 -

INS1000
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 410 x 146.5 14 18 -

INS1250
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 410 x 146.5 14 18 -

INS1600
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 410 x 146.5 14 18 -

INS2000
b b b b b b b b b b b 60 b b b b b 50 440 x 347.5 x 227.5 440 x 462.5 x 227.5 35 45 -

INS2500
b b b b b b b b b b b 60 b b b b b 50 440 x 347.5 x 227.5 440 x 462.5 x 227.5 35 45 -

35

Interpact INV

Interpact INV100 to 630 switch-disconnectors

Interpact INV switch-disconnectors


056650a-48

Number of poles

Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3


Conventional thermal current (A) Conventional thermal current in enclosure Rated insulation level (V) Impulse-withstand voltage (kV) Rated operational voltage (V) Ith Ithe Ui Uimp Ue at 60 C at 60 C AC 50/60 Hz AC 50/60 Hz DC AC 50/60 Hz Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Uninterrupted duty Intermittent duty Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) 1s 3s 20 s 30 s Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V

Rated operational voltage AC20 and DC20 (V) Rated operational current (A) Ie

Interpact INV250 switch-disconnector.

056654a-48

Rated operational power AC23 (kW)

Rated duties Short-circuit making capacity (kA peak) Interpact INV250 emergency-off switch-disconnector. Icm

Short-time withstand current (A rms)

Icw

Suitability for isolation Durability (category A) (O - C-O cycles)

Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution

Upstream protection
See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) 550 A (DC).

36

Interpact INV

INV100
3-4 100 100 750 8 690 250 750 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

INV160
3-4 160 160 750 8 690 250 750 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160

INV200
3-4 200 200 750 8 690 250 750 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200

INV250
3-4 250 250 750 8 690 250 750 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 200 200 200 200

INV320
3-4 320 320 750 8 690 250 750 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320

INV400
3-4 400 400 750 8 690 250 750 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400

INV500
3-4 500 500 750 8 690 250 750 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500

INV630
3-4 630 630 (2) 750 8 690 250 750 630 630 630 630 630 550 550 630 630 630 630 550 550 550 630/630 630/630 630/630 500/630 500/630 550/630 550/630

AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B

DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B

22 22 45 55 55 55 55 b class 120 - 60 % 30 330 8500 4900 2200 1800 b 15000


AC22A AC23A

45 45 75 90 50 110 90 b class 120 - 60 % 30 330 8500 4900 2200 1800 b 15000


AC22A AC23A

55 55 90 110 110 132 160 b class 120 - 60 % 30 330 8500 4900 2200 1800 b 15000
AC22A AC23A

75 75 132 150 150 132 160 b class 120 - 60 % 30 330 8500 4900 2200 1800 b 15000
AC22A AC23A

90 90 160 185 185 220 250 b class 120 - 60 % 50 330 20000 11500 4900 4000 b 10000

110 110 200 220 220 250 400 b class 120 - 60 % 50 330 20000 11500 4900 4000 b 10000

132 150 250 250 250 355 500 b class 120 - 60 % 50 330 20000 11500 4900 4000 b 10000

200 200 315 400 375 400 560 b class 120 - 60 % 50 330 20000 11500 4900 4000 b 10000

AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B

1500 1500 1500


DC22A

1500 1500 1500


DC23A

1500 1500 1500


DC22A

1500 1500 1500


DC23A

1500 1500 1500


DC22A

1500 1500 1500


DC23A

1500 1500 1500


DC22A

1500 1500 1500


DC23A

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200
DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B

1500 b b b III -

1500

1500 b b b III -

1500

1500 b b b III -

1500

1500 b b b III -

1500

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200 b b b b b b b b b b b b III III III III -

37

Interpact INV

Interpact INV100 to 630 switch-disconnectors

Interpact INV switch-disconnectors


Installation
Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate

Connection
By cables By cables with lugs To bare cable connectors Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Directly to terminals To spreaders To vertical-connection adapters

Flat-facing bars Edgewise bars Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module

Indication and measurement auxiliaries

Control, locking and interlocking


Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle By keylock By padlocks By keylock Mechanical

Locking Interlocking

Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle)

Installation and connection accessories


Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm)

Dimensions and weights


Overall dimensions H x W x D (mm) Approximate weight (kg) 3 poles 4 poles 3 poles 4 poles H x W x D (mm)
DB105413

Enclosure dimensions for Ithe

38

Interpact INV

INV100
b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200

INV160
b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200

INV200
b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200

INV250
b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 b b b b b b b b b 15 136 x 140 x 96 136 x 140 x 96 2 2.2 400 x 300 x 200

INV320
b b b b b b b b b b b b b b b b b b b 13,5 < Nm < 16.5 b b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INV400
b b b b b b b b b b b b b b b b b b b 13,5 < Nm < 16.5 b b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INV500
b b b b b b b b b b b b b b b b b b b 13,5 < Nm < 16.5 b b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

INV630
b b b b b b b b b b b b b b b b b b b 13,5 < Nm < 16.5 b b b b b b b b b 50 205 x 185 x 130 205 x 185 x 130 4.6 4.9 600 x 400 x 200

39

Interpact INV

Interpact INV630b to 2500 switch-disconnectors

Interpact INV switch-disconnectors


PB100017a-55

Number of poles

Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3


Conventional thermal current (A) Conventional thermal current in enclosure Rated insulation level (V) Impulse-withstand voltage (kV) Rated operational voltage (V) Rated operational voltage AC20 and DC20 (V) Rated operational current (A) Ith Ithe Ui Uimp Ue at 60 C at 60 C AC 50/60 Hz AC 50/60 Hz DC AC 50/60 Hz Electrical AC

Ie

50/60 Hz 220-240 V

Interpact INV1600 switch-disconnector.

380-415 V 440-480 V (1)

PB100019a-55

500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Uninterrupted duty Intermittent duty Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) 0.5 s 0.8 s 1s 3s 20 s 30 s Mechanical Electrical AC

Rated operational power AC23 (kW)

Interpact INV1600 emergency-off switch-disconnector.

Rated duties Short-circuit making capacity (kA peak) Icm

PB100021a-65

Short-time withstand current (A rms)

Icw

Suitability for isolation Durability (category B) (O - C-O cycles)

50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V

Interpact INV2500 switch-disconnector.

Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution

Upstream protection
See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) For vertical connection busbars only. For horizontal connection busbars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue.

40

Interpact INV

INV630b
3-4 630 630 1000 12 690 750 800 AC21A AC22A AC23A

INV800
3-4 800 800 1000 12 690 750 800 AC21A AC22A AC23A

INV1000
3-4 1000 1000 1000 12 690 750 800 AC21A AC22A AC23A

INV1250
3-4 1250 1250 1000 12 690 750 800 AC21A AC22A AC23A

INV1600
3-4

INV2000
3-4 2000 2000 1000 12 690 750 800 AC23A AC21B AC22B AC23B 1250 1250 1250 1250 1250 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 -

INV2500
3-4 2500 2500 1000 12 690 750 800 AC21B AC22B AC23B 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 -

1600 (2) 1600 (2) 1000 12 690 750 800 AC21B AC22B AC21A AC22A 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1450 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1450 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1600 1250 1250 DC21A DC22A DC23A DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 250 400 500 560 710 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 5000 AC21A AC22A AC23A 250 400 500 560 710 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A 315 560 630 710 900 b class 120 - 60 % 75 330 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A 400 710 800 900 b class 120 - 60 % 75 75 50 42 35 20 10 8 b 3000 AC21A AC22A AC23A

DC23A DC21B DC22B DC23B DC21B DC22B DC23B 1600/2 2000/2 2000/2 2500/2 2500/2 1600/4 2000/4 2000/4 2500/4 2500/4 b class 120 - 60 % 105 105 b class 120 - 60 % 105 105 50 50 50 30 13 11 b 500 AC21B AC22B AC23B 100 100 100 100 100 100 100 100 100 100 -

400 710 800 900 b class 120 - 60 % 75 75

50 42 35 20 10 8 b 3000 AC21B AC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 b b b b b b b b b b III III III III III -

50 50 50 30 13 11 b 500 AC22B AC23B AC21B AC22B AC23B AC22A 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 100 500 100 100 500 DC22A DC23A DC21B DC22B DC23B 500 500 100 100 500 500 100 100 b III -

DC21B DC22B DC23B 100 100 100 100 b III -

41

Interpact INV

Interpact INV630b to 2500 switch-disconnectors

Interpact INS switch-disconnectors


Installation
Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate

Connection
By cables By cables with lugs To bare cable connectors Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Directly to terminals To spreaders To vertical-connection adapters

Flat-facing bars Edgewise bars Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module

Indication and measurement auxiliaries

Control, locking and interlocking


Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle By keylock By padlocks By keylock Mechanical

Locking Interlocking

Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle)

Installation and connection accessories


Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm)

Dimensions and weights


Overall dimensions H x W x D (mm) Approximate weight (kg) 3 poles 4 poles 3 poles 4 poles H x W x D (mm)
DB105413

Enclosure dimensions for Ithe

42

Interpact INV

INV630b
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 340 x 146.5 14 18 -

INV800
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 340 x 146.5 14 18 -

INV1000
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 340 x 146.5 14 18 -

INV1250
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 340 x 146.5 14 18 -

INV1600
b b b b b b b b b b b b b 30 b b b b b 50 300 x 340 x 146.5 300 x 340 x 146.5 14 18 -

INV2000
b b b b b b b b b b b 60 b b b b b 50 440 x 347.5 x 227.5 440 x 462.5 x 227.5 35 45 -

INV2500
b b b b b b b b b b b 60 b b b b b 50 440 x 347.5 x 227.5 440 x 462.5 x 227.5 35 45 -

43

Fupact

Fupact INFp32 to INFp800 switch-disconnector fuses

059000a-2,4x2,12

Fupact INFp switch-disconnector fuses


Number of poles / type of fuse-link 3 poles / 3 fuse-links 4 poles / switched neutral 4 poles / 4 fuse-links

Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3 and EN 60947-1 / EN 60947-3
INFB32.
In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kV) Uimp Rated operational voltage (AC20 and DC20) (V) Ue Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (1) 500/525 V 660/690 V DC 125 V/nbr of poles in series 250 V/nbr of poles in series 440 V/nbr of poles in series 500 V/nbr of poles in series 750 V/nbr of poles in series AC 220/240 V Rated operational power (kW) (3) (motor power given for direct on-line starting) 380/400 V 415 V 500/525 V 660/690 V Rated duties Uninterrupted duty Intermittent duty Icm 415 V Rated short-circuit making capacity (kA peak) Switch-disconnector without fuse (refer to single- phase 500 V fuse limitation curves) 690 V Icn / Icm 415 V (BS fuse-link) Rated short-circuit breaking capacity (kA rms) / Rated short-circuit making capacity (kA peak) (4) 500 V (DIN fuse-link) 690 V (BS/DIN fuse-link) Icw 1s Rated short-time withstand current (A rms) 3s 20 s 30 s Endurance (category A) (CO cycles) Mechanical Electrical AC AC22A 500 V AC22A 690 V AC23A 500 V AC23A 690 V Suitability for isolation Positive contact indication Pollution degree Control Direct front rotary handle Extended front rotary handle Extended lateral rotary handle Locking by padlocks Operating torque (typical for 3 poles switch-disconnector fuses) (Nm) Indication auxiliaries Auxiliary contacts Blown-fuse indicator Fuse monitor Auxiliary contact test position (1) Suitable for 480 V NEMA. (2) AC23B. (3) Some fuse-links limit these values. Motor starting current must be considered separately. (4) Switch-disconnector combined with fuses. (5) Only for NFC fuse-links. (6) Only for DIN fuse-links. Conventional thermal current (A)

056502a-5,8x3,75

INFC63.

056503a-6x4,21

INFD160.

056504a-6,8x4,19

INFD400.

44

Fupact

INFp32
NFC-BS NFC-BS NFC 32 3.5 32 3.5 800 8 800 750 750 AC22A AC23A 32 32 32 32 32 32 32 32 32 32 DC22A DC23A 32/2 32/2 32/4 32/4 32/4 32/4 8 14 15 18 25 b class 120-60 % 9 7.5 6 80/176 100/220 50/105 1000 570 220 180 10000 1500 1500 1500 1500 b yes III b b b b 3 b b (5) b b (standard)

INFD40
DIN DIN 40 4.5 40 4.5 800 8 800 750 750 AC22A AC23A 40 40 40 40 40 40 40 40 40 40 DC22A DC23A 40/2 40/2 40/4 40/4 40/4 40/4 11 18.5 18.5 22 30 b class 120-60 % 9 7.5 6 80/176 100/220 50/105 1000 570 220 180 10000 1500 1500 1500 1500 b yes III b b b b 3 b b b (standard)

INFp63
NFC-DIN-BS NFC-DIN-BS NFC-DIN 63 7.5 63 7.5 800 8 800 750 750 AC22A AC23A 63 63 63 63 63 63 63 63 63 63 (2) DC22A DC23A 63/3 63/3 63/3 63/3 63/3 63/3 18.5 30 30 37 60 b class 120-60 % 17 17 13 80/176 100/220 50/105 2500 1440 560 460 10000 1500 1500 1500 1500 b yes III b b b b 4 b b (5) b b (standard)

INFB100
BS BS 100 12 100 12 800 8 800 750 750 AC22A AC23A 100 100 100 100 100 100 100 100 100 100 (2) DC22A DC23A 100/2 100/2 100/2 100/2 100/2 100/2 100/4 100/4 30 45 55 60 90 b class 120-60 % 22 22 15 80/176 100/220 50/105 5000 2900 1150 950 10000 1500 1500 1500 1500 b yes III b b b b 8 b b b (standard)

INFC125 INFp160
NFC NFC NFC 125 12 125 12 800 8 800 750 750 AC22A AC23A 125 125 125 125 125 125 125 125 125 125 (2) DC22A DC23A 125/2 125/2 125/2 125/2 125/2 125/2 100/4 100/4 37 60 60 80 110 b class 120-60 % 22 22 15 80/176 100/220 50/105 5000 2900 1150 950 10000 1500 1500 1500 1500 b yes III b b b b 8 b b b b (standard) DIN-BS DIN-BS DIN 160 12 160 135 10 12 800 8 800 750 750 AC22A AC23A 160 160 160 160 160 160 160 160 160 160 (2) DC22A DC23A 160/2 160/2 160/2 160/2 160/2 160/2 100/4 100/4 45 80 90 110 132 b class 120-60 % 22 22 15 80/176 100/220 50/105 5000 2900 1150 950 10000 1500 1500 1500 1500 b yes III b b b b 8 b b b (standard)

INFp250
DIN-BS DIN-BS DIN 250 32 250 230 23 27 800 8 800 750 750 AC22A AC23A 250 250 250 250 250 250 250 250 250 250 DC22A DC23A 250/2 250/2 250/2 250/2 250/2 250/2 250/3 250/3 250/3 250/3 70 132 140 170 230 b class 120-60 % 40 40 35 80/176 100/220 50/105 8000 4650 1800 1500 8000 1000 1000 1000 1000 b yes III b b b b 22 b b (6) b b (optional)

INFp400
DIN-BS DIN-BS DIN 400 45 400 360 34 37 800 8 800 750 750 AC22A AC23A 400 400 400 400 400 400 400 400 400 400 DC22A DC23A 400/2 400/2 400/2 400/2 400/2 400/2 400/3 400/3 400/3 400/3 110 210 230 280 330 b class 120-60 % 40 40 35 80/176 100/220 50/105 10000 5800 2250 1850 8000 1000 1000 1000 1000 b yes III b b b 22 b b (6) b b (optional)

INFp630
DIN-BS DIN-BS DIN 630 60 600 570 45 50 800 8 800 750 750 AC22A AC23A 630 630 630 630 630 630 630 630 630 630 DC22A DC23A 630/2 630/2 630/2 630/2 630/2 630/2 630/3 630/3 630/3 630/3 180 315 340 400 540 b class 120-60 % 75 75 60 80/176 100/220 50/105 16000 9250 3600 2950 5000 1000 1000 1000 1000 b yes III b b b 28 b b (6) b b (optional)

INFp800
DIN-BS DIN-BS DIN 800 65 720 55 800 8 800 750 750 AC22A AC23A 800 720 800 720 800 720 800 720 800 720 DC22A DC23A 800/2 800/2 800/2 800/2 800/2 800/2 800/3 800/3 800/3 800/3 200 350 380 470 600 b class 120-60 % 75 75 60 80/176 100/220 50/105 16000 9250 3600 2950 5000 1000 1000 1000 1000 b yes III b b b 28 b b (6) b b (optional)

45

Fupact

Fupact INFp32 to INFp800 switch-disconnector fuses

Fupact INFp switch-disconnector fuses


Type of fuse-link
NFC 10 x 38 14 x 51 22 x 58 NH000 NH00 NH0,1 NH0,1,2 NH3 A1 (44,5) F1 A2 (73,0) A3 (73,0) A4 (93,7) B1 (111) B2 (111) B3 (111) B4 (111) C1 (133) C2 (133) C3 (133)

DIN (NH)

BS (fixing centres in mm) (3)

Installation and connection


Fixed front connection Terminal tightening torque (Nm) Fuse-link bolts tightening torque (Nm) Installation and connection accessories Bare-cable connectors Terminals Neutral link Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) Approximate weight without fuses (kg) Enclosure dimensions for Ithe H x W x D (mm) Temperature derating (4) (5) "Vertical mounting" fuse-links in vertical position Ith (A) 40 45 50 55 60 65 70 35 40 45 50 55 60 65 70

3P 4P 3P 4P

"Horizontal mounting" fuse-links in horizontal position

Ith (A)

(1) Maximum fuse body diameter: 32 mm. (2) Maximum fuse body diameter: 55 mm. (3) A: fuse-link with centre bolted tags. B: fuse-link with offset bolted tags. (4) Derating data is based on: - the maximum rating for fuse-links intended for the device, - maximum heat loss. (5) For installation on a ceiling, derate an additional 10 %.

46

Fupact

INFp32
b b b b b b 2 2 b (standard) b 97 x 106 x 105 97 x 142 x 105 0.7 0.9 300x350x200 NFC-BS 32 30.4 28.8 27.2 25.6 25 24.4 31 29.5 28 26.5 25 23.5 22 20.5

INFD40
b b 2 2 b (standard) b b 97 x 106 x 133 97 x 142 x 133 0.7 0.9

INFp63
b b b b b b b 3.5 2 b (standard) b b 100 x 143 x 128 100 x 188 x 128 1.3 1.6

INFB100
b b b (1) b 15-22 M5: 3.5 M8: 5 b (optional) b b b 140 x 180 x 130 140 x 215 x 130 1.5 1.8

INFC125 INFp160
b b 15-22 b (optional) b b b 140 x 180 x 130 140 x 215 x 130 1.5 1.8 b b b b b b (1) b 15-22 M5: 3.5 M8: 5 b (optional) b b b 140 x 180 x 130 140 x 215 x 130 1.5 1.8

INFp250
b b b b (2) b 30-44 15 b (optional) b b b 162 x 278 x 199 162 x 340 x 199 6.9 7.9

INFp400
b b b b b b 30-44 15 b (optional) b b b 180 x 302 x 206 180 x 372 x 206 7.8 8.8

INFp630
b b b b 50-75 40 b (optional) b b b 232 x 378 x 234 232 x 458 x 234 15.5 19

INFp800
b b b b b 50-75 40 b (optional) b b b 232 x 408 x 234 232 x 498 x 234 17 21

DIN 40 38 36 34 32 30 28 38 36 34 32 30 28 26 24

NFC-DIN-BS 63 60 56.7 53.6 50.4 47.2 44 61 58 55 52.2 49.3 46.4 43 40

BS 100 95 90 85 80 75 70 96 92 87 83 78 74 69 65

NFC 125 119 113 106 100 94 88 121 115 109 103 97 92 86 81

DIN-BS 160 152 144 136 128 120 112 156 148 140 133 126 118 111 103

600 x 350 x 300 / 500 x 400 x 250 DIN-BS DIN-BS 250 400 237 380 225 360 212 340 200 320 187 300 175 280 242 386 230 368 218 350 207 331 195 313 184 295 172 277 161 268

600 x 700 x 300 / 800 x 600 x 270 DIN-BS DIN-BS 630 800 600 760 567 720 536 680 504 640 474 600 441 560 610 772 580 736 550 700 522 662 493 625 464 588 434 552 406 514

47

Fupact

Fupact ISFT100 to ISFT630 fuse-switch disconnectors

Fupact ISFT fuse-switch disconnectors


Number of poles / type of fuse-link
62193a-3,2x4,5

IEC60 269-2-1 Section 1

Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3 and EN 60947-1 / EN 60947-3
In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage (AC20 and DC20) (V) Ue Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (2) 500 V 660/690 V DC/poles in series 125 V /Nbr of poles 220 V /Nbr of poles 440 V /Nbr of poles Rated duties Uninterrupted duty Rated short-circuit breaking capacity (kA rms) / Rated Icn/Icm/In fuse-link 415 V short-circuit making capacity (kA peak)/ In fuse-link (A) (3) 500 V 690 V Endurance (category B) (CO cycles) Mechanical Electrical AC AC22B 415 V AC21B 690 V Suitability for isolation Visible break Pollution degree Control Direct front rotary handle (operator-dependent opening and closing) Locking Padlocks Lead seal Indication auxiliary Auxiliary contacts Blown-fuse indicator Conventional thermal current (A)

ISFT100.

62194a-3,6x4,85

ISFT160.

62195a-5x5,35

Installation and connection accessories


Mounting position Bare-cable connectors Other connectors Horizontal Vertical For bare Cu/Al cables For flexible bars

ISFT630.

Distribution connector Lugs for copper cables Comb busbars Insulated comb covers Incoming connector for comb busbars Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) Approximate weight without fuse-links (kg) (1) With 95 mm2 connector. (2) Suitable for 480 V NEMA. (3) Fuse-switch disconnector with fuse-links.

3P 3P

48

Fupact

ISFT100
3P/DIN (NH) 160 (1) 9 160 (1) 9 690 6 690 440 690 AC21B 160 160 100 100 100 DC21B 100/1 100/1 100/1 b 80 / 176 / 100 50 / 105 / 100 50 / 105 / 100 2000 300 300 b b III b b b b b b b b b b 141 x 89 x 71 0.46

ISFT160
3P/DIN (NH) 160 12 160 12 800 8 690 440 800 AC21B 160 160 160 160 100 DC21B 160/1 160/1 160/2 b 50 / 105 / 160 50 / 105 / 160 50 / 105 / 100 1600 200 200 b b III b b b b b b b b b b b b 163 x 107 x 80 0.64

ISFT250
3P/DIN (NH) 250 23 250 23 800 8 690 440 800 AC21B 250 250 250 250 250 DC21B 250/1 250/1 250/2 b 50 / 105 / 250 50 / 105 / 250 50 / 105 / 200 1600 200 200 b b III b b b b b b b b b 246 x 186 x 110 2.06

ISFT400
3P/DIN (NH) 400 34 400 34 800 8 690 440 800 AC21B 400 400 400 400 400 DC21B 400/1 400/1 400/2 b 50 / 105 / 400 50 / 105 / 400 50 / 105 / 315 1000 200 200 b b III b b b b b b b b b 271 x 210 x 127 2.96

ISFT630
3P/DIN (NH) 630 48 630 48 800 8 690 440 800 AC21B 630 630 630 630 630 DC21B 630/1 630/1 630/2 b 50 / 105 / 630 50 / 105 / 630 50 / 105 / 500 1000 200 200 b b III b b b b b b b b b 271 x 250 x 132 4.00

AC22B 160 160 DC22B -

AC22B 160 160 DC22B -

AC22B 250 250 DC22B -

AC22B 400 400 DC22B -

AC22B 630 630 DC22B -

49

Fupact

Fupact ISFT100 to ISFT630 fuse-switch disconnectors

Fupact ISFT fuse-switch disconnectors


Type of fuse-link
DIN NH000 DIN NH00 DIN NH1 DIN NH2 DIN NH3

Installation and connection


Symmetrical rail Direct connection on backplate Push-on connection to 60 mm busbars Hook-on connection to 60 mm busbars Hook-on connection to 100 mm busbars Tightening torque (Nm) Temperature derating (with gG fuse-link) (1) (2) "Vertical mounting" fuse-links in vertical position

Ith (A)

"Horizontal mounting" fuse-links in horizontal position

Ith (A)

40 C 45 C 50 C 55 C 60 C 65 C 70 C 40 C 45 C 50 C 55 C 60 C 65 C 70 C

(1) Derating data is based on: - the maximum rating for fuse-links intended for the device, - maximum heat loss. (2) For installation on a ceiling, derate an additional 10 %. (3) With 100/160 A fuse-link.

50

Fupact

ISFT100
b b b see "New fusepact range from 32 to 800 A - Fupact" catalogue 100/160 (3) 100/160 95/152 90/144 85/136 80/128 75/120 70/112 100/160 95/152 90/144 85/136 80/128 75/120 70/112

ISFT160
b b b b b -

ISFT250
b b b b b

ISFT400
b b b b

ISFT630
b b b b

160 160 152 144 136 128 120 112 160 152 144 136 128 120 112

250 250 238 225 213 200 188 175 250 238 225 213 200 188 175

400 400 380 360 340 320 300 280 400 380 360 340 320 300 280

630 630 599 567 536 504 473 441 630 599 567 536 504 473 441

51

Fupact

Fupact ISFL160 to ISFL630 fuse-switch disconnectors

Fupact ISFL fuse-switch disconnectors


Number of poles / type of fuse-link
62196a-2,5x6,49

IEC60 269-2-1 Section 1

Electrical characteristics as defined by IEC 60947-1 / IEC 60947-3 and EN 60947-1 / EN 60947-3
In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage (AC20 and DC20) (V) Ue Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (1) 500 V 660/690 V DC/poles in series 125 V /Nbr of poles 220 V /Nbr of poles 440 V /Nbr of poles Rated duties Uninterrupted duty Rated short-circuit breaking capacity (kA rms) / Rated Icn/Icm/In fuse-link 415 V short-circuit making capacity (kA peak)/ In fuse-link (A) (2) 500 V 690 V Endurance (category B) (CO cycles) Mechanical Electrical AC AC22B 415 V AC21B 690 V Suitability for isolation Visible break Pollution degree Control Direct front rotary handle (operator-dependent opening and closing) Locking Padlocks Lead seal Indication auxiliary Auxiliary contacts Blown-fuse indicator Current transformer Conventional thermal current (A)

ISFL160.

62197a-2,08x9,65

Installation and connection accessories


Mounting position Connector Horizontal Vertical For bare Cu/Al cables For flexible bars

ISFL250.

Lugs for Cu/Al cables Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) Approximate weight without fuse-links (kg) (1) Suitable for 480 V NEMA. (2) Fuse-switch disconnector with fuse-links.

3P 3P

52

Fupact

ISFL160
3P/DIN (NH) 160 12 160 12 800 8 690 440 800 AC21B 160 160 160 160 100 DC21B b 50 / 105 / 160 50 / 105 / 160 50 / 105 / 100 1600 200 200 b b III b b b b b b b b b b 456 x 50 x 159 1.35

ISFL250
3P/DIN (NH) 250 23 250 23 800 8 690 440 800 AC21B 250 250 250 250 250 DC21B b 100 / 220 / 250 50 / 105 / 250 50 / 105 / 200 1600 200 200 b b III b b b b b b b 755 x 100 x 192 6.35

ISFL400
3P/DIN (NH) 400 34 400 34 800 8 690 440 800 AC21B 400 400 400 400 400 DC22B b 100 / 220 / 400 50 / 105 / 400 50 / 105 / 315 1000 200 200 b b III b b b b b b b 755 x 100 x 192 6.35

ISFL630
3P/DIN (NH) 630 48 630 48 800 8 690 440 800 AC21B 630 630 630 630 630 DC22B b 100 / 220 / 630 50 / 105 / 630 50 / 105 / 500 1000 200 200 b b III b b b b b b b 755 x 100 x 192 6.35

AC22B 160 160 DC22B -

AC22B 250 250 DC22B -

AC22B 400 400 DC21B -

AC22B 630 630 DC21B -

53

Fupact

Fupact ISFL160 to ISFL630 fuse-switch disconnectors

Fupact ISFL fuse-switch disconnectors


Type of fuse-link
DIN NH000 DIN NH00 DIN NH1 DIN NH2 DIN NH3

Installation and connection


Hook-on connection to 60 mm busbars Direct connection to 100 mm busbars Direct connection to 185 mm busbars To 60 mm busbars using single-device conversion kit To 185 mm busbars using single or double device conversion kit Tightening torque (Nm) Temperature derating (with gG fuse-link) (1) "Vertical mounting" fuse-links in vertical position

Ith (A)

"Horizontal mounting" fuse-links in horizontal position

Ith (A)

40 C 45 C 50 C 55 C 60 C 65 C 70 C 40 C 45 C 50 C 55 C 60 C 65 C 70 C

(1) Derating data is based on: - the maximum rating for fuse-links intended for the device - maximum heat loss.

54

Fupact

ISFL160
b b b b b b see "New fusepact range from 32 to 800 A - Fupact" catalogue 160 152 144 136 128 120 112 160 152 144 136 128 120 112

ISFL250
b b -

ISFL400
b b -

ISFL630
b b -

250 238 225 213 200 188 175 -

400 380 360 340 320 300 280 -

630 599 567 536 504 473 441 -

55

Vigirex

Protection and monitoring relays

Protection relays (2) RH10


PB100435a_18 PB100430a_19

RH21
PB100433a_18 PB100431a_19

All Vigirex products are type A devices (1), also covering the requirements of type AC devices.

Functions
Protection Local indications Remote indications (hard-wired) Remote indications (via communication) Display of measurements b b b b b b b b 1 fixed instantaneous threshold choose from 0.03 A to 1 A b b b b b b b b 2 user-selectable thresholds 0.03 A or 0.3 A -

Wiring
Optimum continuity of service Optimum safety (failsafe)

Mounting
DIN rail Front-panel mount

Rated operational voltage


1 DC voltage range from 12 to 48 V 1 DC voltage range from 24 to 130 V and AC 48 V 6 AC voltage ranges from 12 to 525 V 4 AC voltage ranges from 48 to 415 V

Thresholds
Fault (In)

Alarm

Pre-alarm

Time delays
Fault Instantaneous Instantaneous for In = 0.03 A 1 user-selectable time delay instantaneous or 0.06 s for In = 0.3 A -

Alarm

Pre-alarm

Display and indications


Voltage presence (LED and/or relay) (6) Threshold overrun fault (LED) alarm (LED and relay) pre-alarm (LED and relay) Leakage current (digital) Settings (digital) b b b b b see "Low-voltage residual-current protection relays - Vigirex" catalogue b b b b b see "Low-voltage residual-current protection relays - Vigirex" catalogue

Test with or without actuation of output contacts


Local Remote (hard-wired) Remote (hard-wired for several relays) Remote (via communication)

Communication
Suitable for supervision (internal bus)

Characteristics

Sensors
Merlin Gerin A, OA, E toroids (7) up to 630 A b Merlin Gerin rectangular sensors up to 3200 A b (1) Type A relays up to IN = 5 A. (2) Relay with output contact requiring local, manual reset after fault clearance. (3) Relay with output contact that automatically resets after fault clearance. b b (4) Mandatory with an RMH (multiplexing for the 12 toroids). (5) Mandatory with an RM12T (multiplexing for the 12 toroids).

56

Vigirex

RH99
PB100434a_18 PB100432a_19

RH197P
PB100715a_20

Monitoring relays (3) RHUs or RHU RH99


059483a_21 PB100429Ra_18 PB100432Ra_20

RMH
059484Ra_21 059485Ra_27
0

(4)

b b b b b b b b 9 user-selectable thresholds from 0.03 A to 30 A -

b b b b (8) b b b b b 19 user-selectable thresholds from 0.03 A to 30 A Fixed: 50 % In

b b b b except RHUs b b b b b 1 adjustable threshold from 0.03 A to 30 A 1 adjustable threshold from 0.015 A to 30 A -

b b b b b b -

b b b b 12 measurement channels (5) b 220 to 240 V AC -

9 user-selectable thresholds from 0.03 A to 30 A -

1 adjustable threshold/channel from 0.03 A to 30 A 1 adjustable threshold/channel from 0.015 A to 30 A -

9 user-selectable time delays instantaneous to 4.5 s

7 user-selectable time delays instantaneous to 4.5 s instantaneous

1 adjustable threshold instantaneous to 4.5 s 1 adjustable threshold instantaneous to 4.5 s -

9 user-selectable time delays instantaneous to 4.5 s

1 adjustable threshold/channel instantaneous to 5 s

1 adjustable threshold/channel instantaneous to 5 s b b b b b b b b see "Low-voltage residual-current protection relays - Vigirex" catalogue

b b b b b see "Low-voltage residual-current protection relays - Vigirex" catalogue

b (9) b b on bargraph (10)

b b b b b b b b b except RHUs b except RHUs see "Low-voltage residual-current protection relays Vigirex" catalogue

b b b b b see "Low-voltage residual-current protection relays - Vigirex" catalogue

b b b see "Low-voltage residual-current protection relays Vigirex" catalogue

b b b b b b (6) Depending on the type of wiring (optimum continuity of service or optimum safety). (7) see "Low-voltage residual-current protection relays - Vigirex" catalogue.

b b (8) On a bargraph. (9) No voltage presence relay. (10) With actuation of contacts only.

b b

Schneider Electric Industries SAS


89, boulevard Franklin Roosevelt F - 92500 Rueil-Malmaison (France) Tel : +33 (0)1 41 29 85 00 http://www.schneider-electric.com http://www.merlin-gerin.com
http://www.schneider-electric.co

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper.

Design: Schneider Electric Photos: Schneider Electric Printed: INGOPRINT 03-2005

ABTED296014V1EN

ART73433 2005 - Schneider Electric - All rights reserved

Vous aimerez peut-être aussi