Features/Benefits
Easy installation or retrofit DIN-rail mountable Fail-safe, self-protected design Remote indicator (optional) Visual indicator IP20 finger-safe design Small footprint No additional overcurrent protection devices required
Applications:
AC/DC distribution Power supplies Industrial automation Telecommunications Motor controls and starter systems Programmable logic controller (PLC) applications Power transfer equipment HVAC applications AC drives UPS systems Security systems
Ratings:
Max Discharge Current Volts : 50kA per phase : 120V to 600V AC : 600V to 1000V DC (PV only)
Dimensions
Poles 1 Pole 2 Pole 3 Pole 4 Pole in 0.70 1.39 2.10 2.80 A mm 17.8 35.5 53.3 71.0 ** Wire Size: 6-14 AWG ** Torque: 15 lbs-in ** Use 35mm DIN-rail
SCCR : 200kA Operating & storage temp : -40C to +85C : #6 to #14AWG : 20kA (most models) Wiring range: Nominal discharge current
Approvals:
UL 1449 Third Edition Approved, File E210793 Type 4 UL Recognized Component (Tested to UL Type 2 SPD) IEC 61643-11 RoHS Compliant ANSI/IEEE C62.41 CE
NO 1 Common 2 NC
N2
Terminal Torque 2.2 lb-in Cont. between Comm + NO = Product Offline, Not Protected Cont. between Comm + NC = Product Online, Protected
Catalog Numbers
Catalog No. ST1201PG(M) ST2301PG(M) ST2771PG(M) ST2083PY(M) ST2083PYG(M) ST240SPG(M) ST480SPG(M) ST2403PDG(M) ST4803PY(M) ST4803PYG(M) ST4803PDG(M) ST6003PY(M) ST6003PYG(M) Catalog No. PV ST600PVM ST600YPVM ST1000PVM Nominal Voltage (VAC) 120 240 277 120/208 120/208 120/240 240/480 240D 277/480 277/480 480D 347/600 347/600 MCOV L-G 180 270 320 360 180 180 270 270 500 320 550 690 420 Ucpv* 720 750 1250
Indicates PV only Nominal Discharge Current (In, kA) 20 20 20 20 20 20 20 20 20 20 20 20 20 Max. Discharge Current SCCR (Imax, 8/20s, (kA) kA) 50 50 50 50 50 50 50 50 50 50 50 50 50 Imax Discharge Current (Imax, 8/20s, kA) 40 40 40 200 200 200 200 200 200 200 200 200 200 200 200 200 Voltage Protection Level (Up @ In, kV) <1.5 <2.4 <3.0 Voltage Protection Rating (VPR) L-N 500 800 900 500 500 500 800 1200 900 1500 1200 L/R <= 1mS <= 1mS <= 1mS L-G 900 800 2000 1500 2500 700 800 N-G 500 L-L 900 900 900 1500 1500 2000 1800 3000 2500 2000 Circuit Connection Wiring Diagrams A A A D C B B C D C C D C No. Wiring of Diagrams Poles 2 3 3 E F F
No. of Poles 1 1 1 4 3 2 2 3 4 3 3 4 3
Freq (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Iscwpv** (kA) 10 10 10
No. of Wires 2 2 2 5 4 3 3 4 5 4 4 5 4
* Ucpv: Maximum continuous operating DC voltage. **Values based upon SPD type 2 testing
L2
G
L+
L-
G/N
G/N
G/N
L1 N
L1 L2 L3 G
L1 L2 N L3 G
N G
L2 G
For the most current product performance data visit ep-us.mersen.com and use catalog search.