Power Electronics & Control, better known by its brand name PECON, has been associated with Electrical & Power Industry, since 1973. Starting a small way, it has covered a long way becoming one of the most trusted name in transformer protection and temperature surveillance system. PECON is a close knit company with well qualified & trained manpower. PECON is pioneer in electronic type OTI / WTIs, for both Oil cooled and Dry type transformers. With over 50,000 installations in the field, PECON is surely the leader in India in this field. OEM list includes almost all majors in transformer industries in INDIA. Our products are also exported to European & U.S. markets.
Group Company
Associate Company Via L. da Vinci 54/56 - 20094 Corsico (MI) - ITALY Electronic type temperature survillience systems and ventillations fans for transformers.
INDEX
TR-7570 4 Channel WTS with 4-20mA
TR-7570-C
TR-7576
TR-7576-C
TR-7576-Rx
TR-7576-Cx
TR-7577-Rx
TR-7543
TR-7543-C
TR-7544
TR-7544-C
TR-7541-M
TR-7541-C
TR-7578
TR-7578-C
TR-7560
S-02
Sensor Pt-100 10
JB-01
3 Channel WTS TR-8080-FO+ For HT & EHT Transformer Windings FOXTR-02+ With Fiber Optics Temperature Transmitter, SFO-01 Fiber Optic Sensors & 4-20mA & RS-485 outputs.
11
TPR-05
Thermistor Relay
12
ii
TRM-08
Relay Module
ROM-01
RWTI-400M
RWTI-400C
TR-7551
TR-7551-C
TR-7552
TR-7552-C
RWTI-500M
RWTI-500C
Remote Winding Temperature Indicator with RS-485 from PECON OIT & WTI
S-07M
RTD sensor for OTI & WTI with male BSP threads
S-07F
RTD sensor for OTI & WTI with female BSP threads
17
LR-01
Latch Relay
iii
13
MA-116 MA-112
16 Channel Window Annunciator 12 Channel Window Annunciator 8 Channel Window Annunciator 6 Channel Window Annunciator
MA - 116
10
11
12
CONTROL ROOM
18
MA-108 MA-106
13
14
15
16
Accep Acceptt
Reset Reset
Test
Power
UT-101
UT-102
Temperature Scanner
DIMENSION
96
10
125
Figure 2 to 6
96
90
20
Side View
NT-935
TECSYSTEM PRODUCTS
T-154
NT-133 IT
TTG-240
NOTES
24
iv
TR-7570
Options :
Output Signals
Remote output 1 (4-20mA) Remote output 2 (4-20mA) RS-485 (MODBUS protocol)
TR-7570
YES NO NO
TR-7570-C
NO NO YES
TR-7570-Rx
YES YES NO
TR-7570-Cx
YES NO YES
Terminal details :
Inputs RTD 1 RTD 2 RTD 3 RTD 4 Fault High Outputs Very High Fan Input
Remote o/p
Aux Supply
85 - 270 VAC/DC
TR-7570
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Inputs RTD 1 RTD 2 RTD 3 RTD 4 Fault High Outputs Very High Fan
NC
25 26
28 29 30
Input
TR-7570-C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24
Inputs RTD 1 RTD 2 RTD 3 RTD 4 Fault High Outputs Very High Fan
RS-485 A B
Aux Supply
85 - 270 VAC/DC
NC
25 26
28 29 30
Input
Remote o/p
1 2
Aux Supply
85 - 270 VAC/DC
TR-7570-Rx
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24
Inputs RTD 1 RTD 2 RTD 3 RTD 4 Fault High Outputs Very High Fan
NC
39 40 41 42
28 29 30
Input
TR-7570-Cx
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24
NC
39 40 41 42 28 29 30
Note : For dimension & mounting details, please refer Figure - 2 on Page 20.
APPLICATION NOTE
TECSYSTEM
DIMENSION
CONTROL ROOM
OIL COOLED
OIL COOLED
TR-7576
Options :
Output Signals TR-7576
YES NO NO NO
TR-7576-C
NO NO YES NO
TR-7576-Rx
YES YES NO NO
TR-7576-Cx TR-7576-CP
YES NO YES NO NO NO NO YES
CONTROL ROOM
Remote output 1 (4-20mA) Remote output 2 (4-20mA) RS-485 (MODBUS protocol) Profibus- DP protocol
Terminal details :
Inputs Outputs RTD 5 RTD 6 Input Fan
Aux. Supply 85-270 VAC-DC
DIMENSION
RTD 1
RTD 2
RTD 3
RTD 4
Remote o/p
Fault
High V.High
TR-7576
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Inputs RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6
21 22 23 24 25 26 27 28 29 30 31
Outputs Input Fan
Aux. Supply 85-270 VAC-DC
TR-7576-C
RS-485 A B G
Fault
High V.High
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 41 42 43 21 22 23 24 25 26 27 28 29 30 31
Inputs Outputs RTD 5 RTD 6 Input Fan
Aux. Supply 85-270 VAC-DC
TECSYSTEM
RTD 1
RTD 2
RTD 3
RTD 4
Remote o/p
1 2
Fault
High V.High
TR-7576-Rx
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 39 40 41 42 21 22 23 24 25 26 27 28 29 30 31
Inputs RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 Remote o/p RS-485 A B Outputs Fault High V.High Fan Input
Aux. Supply 85-270 VAC-DC
TR-7576-Cx
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 39 40 41 42
21 22 23 24 25 26 27 28 29 30 31
Outputs Input Fan
Aux. Supply 85-270 VAC-DC
APPLICATION NOTE
TR-7576-CP
Profibus DP A B G
Fault
High V.High
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 41 42 43 21 22 23 24 25 26 27 28 29 30 31
Note : For dimension & mounting details, please refer Figure - 2 on Page 20.
Salient features :
Seven channel temperature scanner. Temperature indication range : 20 to 250 C. Fan exerciser function. Test Function to simulate operation of WTS. Three relay outputs for High (Alarm), Very High (Trip) and Fault / Fan (configure either as Fan or Fault relay at site). Independent set of setpoints for 7th Channel. 4-20 mA / RS-485 output for remote temperature indication and / or DAS / SCADA application (refer options). Aux. Supply: 85-270 VAC/DC (Optionally 20-50 VAC/DC).
TR-7577-Rx
Options :
Output Signals
Remote output 1 (4-20mA) Remote output 2 (4-20mA) RS-485 (MODBUS protocol)
TR-7577-Rx
YES YES NO
TR-7577-Cx
YES NO YES
Terminal details :
Inputs
RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 RTD 7
Remote o/p
Outputs
Input
TR-7577-Rx
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 40 41 42
Inputs
RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 RTD 7 Remote o/p
23 24 25 26 27 28 30 31
Outputs
High V.High Fan
FLT/
Input
Aux. Supply 85-270 VAC-DC
TR-7577-Cx
RS-485 A B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 40 41 42
23 24 25 26 27 28 30 31
Note : For dimension & mounting details, please refer Figure - 2 on Page 20.
APPLICATION NOTE
TECSYSTEM
DIMENSION
CONTROL ROOM
OIL COOLED
Salient features :
Single channel temperature indicator. Temperature indication range : -20 to 250 C. Test function to simulate operation of WTI. 4 Relay outputs for Fault, Fan, Alarm & Trip. Fan relay is rated for 10A @ 230VAC. 4-20mA / RS-485 output for remote temperature indication and / or DAS / SCADA application (refer options). Enclosure : Noryl (Fire retardant material). Aux. Supply : 85-270 VAC/DC (Optionally 20-50 VAC/DC).
CONTROL ROOM
OIL COOLED
TR-7543
Options :
Output Signals
Remote output (4-20mA) RS-485 (MODBUS protocol)
TR-7543
YES NO
TR-7543-C
NO YES
DIMENSION
Terminal details :
TECSYSTEM
Input
Aux. Supply 85-270 VAC-DC
Input RTD
Output
Remote o/p
TR-7543
E L
1 2 3
Input
Aux. Supply 85-270 VAC-DC
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Outputs Fault Fan Alarm Trip Input RTD
28 29
Output
TR-7543-C
RS-485 A B G
E L
APPLICATION NOTE
1 2 3
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
30 31 32
Note : For dimension & mounting details, please refer Figure - 3 on Page 20.
TR-7544
CONTROL ROOM
Output RTD 4
Options :
Signals
Input signal Remote output signal (4-20mA) RS-485 (MODBUS protocol)
TR-7544
RTD, Pt-100 YES NO
TR-7544-C
RTD, Pt-100 NO YES
TR-7544-SP
4-20mA YES NO
Terminal details :
Input
Aux. Supply 85-270 VAC-DC
Inputs RTD 3
Remote o/p
TR-7544
E L
1 2 3
Input
Aux. Supply 85-270 VAC-DC
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 28 29
Outputs Fault Fan Alarm Trip RTD 1 RTD 2 Inputs RTD 3 RTD 4 Output
TR-7544-C
RS-485 A B G
E L
1 2 3
Input
Aux. Supply 85-270 VAC-DC
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 30 31 32
Outputs Fault Fan Alarm Trip CH # 1 4-20mA Inputs CH # 2 CH # 3 CH # 4 Output
Remote o/p
NC
E L
NC
NC
NC
1 2 3
4 5 6 7 8 9 10 14 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
Note : For dimension & mounting details, please refer Figure - 3 on Page 20.
APPLICATION NOTE
TR-7544-SP
TECSYSTEM
DIMENSION
OIL COOLED
Salient features :
Single channel temperature scanner. Temperature indication range : 50 to 300 C. Two relay outputs for Alarm & Trip. 4-20mA / RS-485 output for remote temperature indication and / or DAS / SCADA application (refer options). Enclosure : Weatherproof Aluminum die cast (IP-65), with polycarbonate viewing window. Aux. Supply : 85-270 VAC/DC (Optionally 20-50 VAC/DC).
OIL COOLED
TR-7541-M
TR-7541-M
CONTROL ROOM
Options :
Output Signals
Remote output (4-20mA)
TR-7541-M
YES NO
TR-7541-C
YES YES
DIMENSION
Terminal details :
Output Input RTD
Terminals not provided
Input
Aux Supply
85 - 270 VAC/DC
TECSYSTEM
Remote o/p
TR-7541-M
NC
1 2 3 4 5
Output Input RTD
4142 43
Output
6 7 8 9
Outputs Alarm Trip
10 11 12
Input
Aux Supply
85 - 270 VAC/DC
Remote o/p
TR-7541-C
RS-485 A B G
NC
1 2 3 4 5
4142 43
6 7 8 9
10 11 12
APPLICATION NOTE
Note : For dimension & mounting details, please refer Figure - 2 on Page 20.
Salient features :
OIL COOLED
Eight channel temperature scanner. Temperature indication range : 20 to 250 C. Four relay outputs for Fault, Fan, Alarm & Trip. 4-20mA / RS-485 output for remote temperature indication / DAS / SCADA application (refer options). Aux. Supply : 85-270 VAC/DC (Optionally 20-50 VAC/DC).
Options :
Output Signals
Remote output (4-20mA) RS-485 (MODBUS protocol)
TR-7578
YES NO
TR-7578-C
YES YES
Terminal details :
Inputs RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 RTD 7 RTD 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
TR-7578
Output
Input Fan
VAC-DC
NC
25 26 28 29 30 31 32 33 34 3536 37 38 39 40 41 42
Inputs RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 RTD 7 RTD 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
TR-7578-C
Output
RS-485
NC
25 26 28 29 30 31 32 33 34 3536 37 38 39 40 41 42 71 72 73
Note : For dimension & mounting details, please refer Figure - 1 on Page 9.
APPLICATION NOTE
VAC-DC
A B G
TECSYSTEM
DIMENSION
CONTROL ROOM
TR-7578
OIL COOLED
Temperature indication range : 50 to 300 C. Four relay outputs for Fault, Fan, Alarm & Trip. SPT-04 is designed for four S-02 inputs. Models with more
TR-8080 spt
CONTROL ROOM
i/p channels are also available. PECON proprietary Data Bus for communication between TR-8080 spt & SPT-04. 4-20mA / RS-485 output for remote temperature indication / DAS / SCADA application. Enclosures : (A) TR-8080 spt : Weatherproof Aluminum die cast (IP-65). (B) SPT-04 : 35 mm. Din Rail mount, Base - Polyamide. Aux. Supply : 85-270 VAC/DC (Optionally 20-50 VAC/DC).
SPT-04
Schematic Diagram :
0
3
DIMENSION
White
Red
TECSYSTEM
Terminal details :
Data Bus
P+ P- D+ D-
Outputs
Red
Remote o/p
Fault
RS-485 A B G
TR-8080 spt
NC
61 62 63 64 65 6667 68 69 70 71
Inputs
72 73 74 75 7677 78 79 80 81 82 83 84 85 86 87
Data Bus
APPLICATION NOTE
RTD 1
RTD 2
RTD 3
RTD 4
P+ P- D+ D-
SPT-04
1 2 3 4 5 6 7 8 9 10 11 12 61 62 63 64
Note : For dimension & mounting details of TR-8080 spt, please refer Figure - 2 on Page 20. For dimension & mounting details of SPT-04, please refer Figure - 5 on Page 21.
TR-7560
Terminal details :
Outputs Inputs RTD CH-R RTD CH-Y RTD CH-B Outputs Alarm Trip Input
Aux Supply
110 / 240 VAC
TR-7560
240 110 N
1 2 3 4
5 6 7 8 9 10 11 12 13 15 16 17 18
19 20 21
260
235 135
5 235 + 0
315
330
EARTHING CONNECTION
FRONT VIEW
SIDE VIEW
MOUNTING DETAILS
Figure - 1
APPLICATION NOTE
TECSYSTEM
5 205 + 0
DIMENSION
CONTROL ROOM
OIL COOLED
RTD Sensor
S-02
Salient features :
Suitable to all our WTI / WTS. 3 wire, Pt-100 type sensor ( IEC-60751, Class B ). Temperature range : 50 to 200 C. Standard lead length : 1, 1.5, 2, 3, 5 meter(s) ( other lengths are available on demand ). Dielectric strength : 2K VAC rms, 50 / 60 Hz for 1 min.
OIL COOLED
S-02
Sensor details :
White
CONTROL ROOM
Max. 4 mm
Red Red 40 mm max. Extention leads teflon over teflon insulated silver plated copper wires 24/7/32 AWG terminated on Bootlace ferrules (Standard lead length is 1000 mm +25 mm )
These sensors are tested for : 1) Dimensions 2) Calibration at 50OC, 100 OC & at 180 OC 3) Dielectric Strength : 2KV rms for 1 min.
Note : 1) RTD Sensor S-02 is suitable over -50 to +200 OC temperature range 2) Sensor S-02 is Class B (IEC-60751) permissible error OC = [ 0.3 + (.005 x t) ] where t is the temperature in OC. 3) Longer lead lengths are available for specific needs.
Junction Box
DIMENSION
JB-01
Salient features :
Suitable for four S-02 sensor terminations. Material : ABS. Protection : IP-66 / NEMA 4X. Flammability : UL 94 HB.
APPLICATION NOTE
10
Pt - 100
JB-01
Red
Red
windings of the transformer where very high voltage insulation is required. Temperature indication range : 45 to 200 C. Four relay outputs for Fault, Fan, Alarm & Trip. 4-20mA and RS-485 MODBUS RTU slave protocol available for remote temperature indication / DAS / SCADA application. Aux. Supply : 85-270 VAC/DC ( Optionally 20 - 50 VAC/DC ).
TR-8080-FO
SFO-01 * FOXTR-02 *
* These parts are brought to you by PECON from our associates M/s. OSENSA, Canada.
Schematic Diagram :
Temperature Display & Scanner Unit TR-8080-FO TR-8080-FO
Data Bus
Fiber Optic Temperature Transmitter FOXTR-02 Fiber Optic Temperature Sensors SFO-01
64 63 62 61
RS-485
B
RS-485
Power Supply
FO Temp. Probe
FO Temp. Probe
FO Temp. Probe
H. T. Coils
Terminal details :
Data Bus
P+ P- D+ D-
Outputs
Remote o/p
Fault
RS-485 A B G
TR-8080-FO
NC
61 62 63 64 65 6667 68 69 70 71
72 73 74 75 7677 78 79 80 81 82 83 84 85 86 87
Note : For dimension & mounting details of TR-8080-FO, please refer Figure - 2 on Page 20.
11
OIL COOLED
Thermistor Relay
TPR-05
Salient features :
Input : PTC Thermistors. Up to 3 PTCs can be connected in series for three phase
OIL COOLED
Terminal details :
windings in series for Alarm, Trip & Fan control. Relay outputs for Alarm, Trip & Fan control. Enclosure : Cover - Polycarbonate & Base - Noryl. Mounting : DIN rail TS-35 / TS-35D as per DIN 46277-3. Aux. Supply : 20 - 270 VAC/DC.
TPR-05
TPR-05
Input
Aux. Supply 20-270 VAC-DC
CONTROL ROOM
1 2
4 5 6 7 8 9 10 11 12
19 20 21 22 23 24
Note : For dimension & mounting details, please refer Figure - 6 on Page 21.
Thermistor Sensors
Salient features :
Sensor : PTC thermistor. Assembly : Single sensor. Diameter : Max. 4 mm. Lead Length : 500 mm. (+/- 10 mm) (Other lead lengths available on demand). Choice of wide temperature range for sensors ( 70 to 160 C ).
DIMENSION
19 20 21 22 23 24
Prog. Switches Trip Reset
TECSYSTEM
Respone Temp. C
70 80 90 100 110 120
F A T
Sensors for fan
Fan Alm Trp Sensor Fault
Power Test
Email : pecon@vsnl.com
3 PTCs in series
20-270 VAC/DC 1 2 4
Fan
Alarm
Trip
9 10 11 12
APPLICATION NOTE
Alarm
Trip Coil
SUPPLY
12
Relay Module
TRM-08
Salient features :
External relay module with built in power supply. Can be used for multiplying relay contact outputs. Can be driven from signal relay contacts for connecting
power circuits. Mounting : DIN rail TS35 / TS-35D as per DIN 46277-3. Built in power supply & as such no need of external 24VDC power supply module. Economical and saves space. Aux. Supply : 85 - 270 VAC/DC ( Optionally 20 - 50 VAC/DC ).
TRM-08
Terminal details :
Inputs (External N/O contacts) COM R1 R2 R3 R4 R5 R6 R7 R8 Input
Aux Supply
85 - 270 VAC/DC
TRM-08
1 2 3 4 5 6 7 8 9 10 18 19 20
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
Salient features :
Input : RS-485 signal from WTS type TR-7570-C,
TR-7570-Cx, TR-7576-C, TR-7576-Cx, TR-7577-Cx, TR-7544-C & TR-7578-C. Outputs : Three isolated 4-20mA current signals corresponding to first three RTD channels of WTS. Linearity : +/- 0.5%, max load 300 ohms. Mounting : Din rail TS35 / TS-35D as per DIN 46277-3. Aux. Supply : 85-270 VAC/DC ( Optionally 20-50 VAC/DC ).
ROM-01
Terminal details :
Input
Aux Supply
DATABUS
Outputs
ROM-01
1 2 3
41 42 43
11 12 13 14 15 16 17 18
13
APPLICATION NOTE
85 - 270 VAC/DC
RS-485 A B G
Remote o/p # 1
Remote o/p # 2
Remote o/p # 3
TECSYSTEM
DIMENSION
CONTROL ROOM
OIL COOLED
OIL COOLED
Enclosure : ABS ( IP-54 for face ). Aux. Supply : 85-270 VAC/DC ( Optionally 20-50 VAC/DC ). Terminal details :
Outputs Inputs
Aux. Supply 4-20mA Input 85-270 VAC-DC -
RWTI-400M
4-20mA Output
RWTI-400M +
1 2
9 10
15 16
CONTROL ROOM
DIMENSION
RWTI-400C
Schematic details for RWTI-400C :
Field
WTS
Control Room
Isolated Current Signal RWTI-400C 4-20 mA Output
TECSYSTEM
A B
RS-485
14 A 15 B
Terminal details :
Outputs Inputs
Aux. Supply 85-270 VAC-DC RS-485 MASTER
APPLICATION NOTE
4-20mA Output
RWTI-400C +
A B G
1 2
9 10
14 15 16
Note : For dimension & mounting details, please refer Figure - 4 on Page 21.
14
TR-7551
Options :
Output Signals
OT Remote output (4-20mA) WT Remote output (4-20mA) RS-485 (MODBUS protocol)
TR-7551
YES YES NO
TR-7551-C
YES YES YES
TR-7552
YES YES NO
TR-7552-C
YES YES YES
Terminal details :
Inputs RTD Outputs Input
CT 5A COM
Terminals not provided
Input
Aux Supply 85 - 270 VAC/DC
Remote o/p
OT WT
TR-7551
Fan
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
Inputs RTD Outputs Input OT Alarm OT Trip Outputs WT Alarm WT Trip Input
Aux Supply 85 - 270 VAC/DC
Remote o/p
OT WT
TR-7551-C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
Inputs RTD Outputs Input
CT 5A COM
Terminals not provided
Input
Aux Supply 85 - 270 VAC/DC
Remote o/p
OT WT
TR-7552
Fan1
Fan2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 26 27 28 29
Inputs RTD Outputs Input OT Alarm WT Alarm Outputs OT/WT Trip Input
Aux Supply 85 - 270 VAC/DC
Remote o/p
OT WT
TR-7552-C
CT RS-485 A B G 5A COM
Fan1
Fan2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 26 27 28 29
Note : For dimension & mounting details, please refer Figure - 2 on Page 20.
15
APPLICATION NOTE
TECSYSTEM
CT RS-485 A B G 5A COM
Fan
DIMENSION
CONTROL ROOM
OIL COOLED
OIL COOLED
signals, one for Oil & one for Winding temperatures for use on SCADA or additional indication. Enclosure : ABS (IP-54 for face). Aux. Supply : 85-270 VAC/DC (Optionally 20-50 VAC/DC).
RWTI-500M
Terminal details :
4-20mA Outputs Input
Aux. Supply 85-270 VAC-DC
4-20mA Inputs
OT
WT
OT
WT
RWTI-500M
CONTROL ROOM
1 2
3 4
9 10
13 14
15 16
DIMENSION
RWTI-500C
Schematic details for RWTI-500C :
Field
OTI / WTI
Control Room
Isolated Current Signals OTI signal
TECSYSTEM
A 8 B 9
14 A 15 B
Terminal details :
4-20mA Outputs Input
Aux. Supply 85-270 VAC-DC RS-485 MASTER
APPLICATION NOTE
OT
WT
A B G
RWTI-500C
1 2
3 4
9 10
14 15 16
Note : For dimension & mounting details, please refer Figure - 4 on Page 21.
16
S-07M
S-07F
CONTROL ROOM
Input Jumper Selction Voltage J1 120 VAC 2-3 240 VAC 3-4 24 VDC 1-2 48 VDC 2-3 125 VDC 3-4 E
Manually reset button for un-latching the relay. LED indication for latched Alarm & Trip contacts. Wide supply voltage, selection with simple jumper settings.
AC Supply : 120 / 240 (+/- 15%) VAC, 50/60 Hz. DC Supply : 24 (+25%) / 48 (+20%) / 125 (+20%) VDC.
Terminal details :
Input Pressure Switch Contact Outputs
Alarm
Trip
LR-01
17
APPLICATION NOTE
1 2
6 7 8 9 10
11 12 13
TECSYSTEM
LR-01
DIMENSION
OIL COOLED
Annunciator
MA-106 / MA-108 / MA-112 / MA-116
Salient features :
Power Electronics & Control
MA - 116
OIL COOLED
10
11
12
13
14
15
16
Accept
Reset
F/O Reset
Test
Power
MA-116
CONTROL ROOM
Terminal details :
Channel Inputs
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
F/O Reset Common
Silence
Accept
Reset
Keys
Input
Aux Supply 85 - 270 VAC/DC
Outputs
Alarm Ring Back
Test
33 34 35 36 37 38
39 40 41
44 45 46 47
Channel Inputs
DIMENSION
10
11
12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
F/O Reset Common
Keys
Silence
Input
Aux Supply 85 - 270 VAC/DC
Outputs
Alarm Ring Back
Test
33 34 35 36 37 38
39 40 41
Channel Inputs
44 45 46 47
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TECSYSTEM
F/O Reset
Silence
Common
MA-108 (8 channels)
Accept Reset
Keys
Input
Aux Supply 85 - 270 VAC/DC
Outputs
Alarm Ring Back
Test
33 34 35 36 37 38
39 40 41
44 45 46 47
Channel Inputs
1 2 3 4 5 6
1 2 3 4 5 6 7 8 9 10 11 12
APPLICATION NOTE
F/O Reset
Silence
Common
Accept
Reset
MA-106 (6 channels)
Keys
Input
Aux Supply 85 - 270 VAC/DC
Outputs
Alarm Ring Back
Test
33 34 35 36 37 38
39 40 41
44 45 46 47
18
UT-101
Options :
Parameters No of channels UT-101 16 UT-101/16 16 UT-101/SP 16 4-20 ma / 0-20 ma / 0-10 ma Open collector 32 192H x 96W x 335D mm 32 8 UT-102/08 8 UT-102/10 10 UT-102/12 12
Channel Inputs.
C/o contacts 8
19
APPLICATION NOTE
TECSYSTEM
DIMENSION
CONTROL ROOM
8 / 10 / 12 / 16 channels are available. Sensor i/ps as per table shown below. 2 set points per channel ( Alarm & Trip ). Relay grouping user settable as per requirement. One relay can be programmed to operate on sensor fault. Hysterisis ( Dead band ) user settable. Time delay for relay operation user settable. Channels can be added or deleted from Scanning & display. Channel hold facility. Programming using front key pad. Channel number, Channel Status and parameter displayed on eight 0.5 inch displays. Channel status are indicated using 3 mm LEDs. Aux. Supply : 90 - 270 VAC/DC.
OIL COOLED
Salient features :
Dimension & Mounting Details for TR-7570, TR-7576, TR-7577-Cx, TR-7577-Rx, TR-7541-M, TR-8080 spt, TR-8080-FO, TR-7551, TR-7552
265
130
235 (+5/-0)
X = X =
OIL COOLED
50
Front Cover Fixing Screw (Open for making connections and settings) M6 Threads
CONTROL ROOM
FRONT VIEW
SIDE VIEW
MOUNTING DETAILS
Figure - 2
DIMENSION
96
15
110
20
TECSYSTEM
96
92
Front View
Notes : - All dimensions are in m.m. - Panel cutout : 92 x 92 mm.
Side View
APPLICATION NOTE
Figure - 3
20
150 (+5/-0)
215
96
10
125
Front View
Note : - All dimensions are in m.m. - Panel cutout : 92 x 92 mm.
Side View
125
Side View
114
Notes : - All dimensions are in m.m. - Din rail mount TS-35 / TS-35D as per DIN 46277-3
Figure - 6
21
APPLICATION NOTE
DIMENSION
CONTROL ROOM
OIL COOLED
96
90
We are in techno-commercial collaboration with this leading European company, manufacturing temperature monitoring units and ventillation fans. Information about full range of their products can be found on www.tecsystem.it
OIL COOLED
CONTROL ROOM
NT935
DIMENSION
TECSYSTEM
Four channel temperature scanner. Temperature indication range : 0 to 240 C. Four relay outputs for Fault, Fan, High (Alarm) &
Very High (Trip). Aux. Supply : 20 - 270 VAC/DC.
APPLICATION NOTE
T154
22
Winding Temperature Indicator ( OTI & WTI ) for Oil cooled transformers
OIL COOLED
NT133 IT
Salient features :
Displays both Oil & Winding temperatures sequentially. Sensors
For oil temperature - RTD Pt-100, IEC-60751 For winding simulation - C.T. Temperature indication range : Oil : 40 to 150 C Winding : 40 to 200 C. Anticipatory Fan control function. Five relay outputs for OT / WT Alarm, OT / WT Trip, Fault, Fan-1 & Fan-2. 4-20mA output for remote temperature indication / DAS / SCADA application can be provided using MULTIMOD 133. RS-485 MODBUS RTU slave protocol for DAS / SCADA application can be provided using MULTIMOD 133. Aux. Supply : 20 - 270 VAC/DC.
NT133 IT
23
APPLICATION NOTE
TECSYSTEM
TTG240
DIMENSION
CONTROL ROOM
Application Note
OIL COOLED
CONTROL ROOM
DIMENSION
TECSYSTEM
Take a 8 to10 inches long 5 to 6 mm ID, mica or epoxy tube, seal its one end with epoxy. You need to tie this tube vertically/length wise on the outer surface of the winding coils by fiber glass or other appropriate tape. Rest of the procedure is as described in suggestion given above.
APPLICATION NOTE
24
Some of our customers may find the above suggestions difficult to implement, They may therefore, explore the possibility of inserting S-02 in the cooling duct of low voltage coil. But in that case, care should be taken so that S-02 is not left hanging. The vibration of the sensor should be arrested using some mechanism or using some bonding / adhesive materials of suitable temperature grade. Connections of S-02 leads to Winding Temperature Scanner ( WTS ). The most appropriate & reliable way of terminating leads of S-02, is to terminate them directly on WTS. This avoids problems arising out of loosening of intermediate terminations and wrong wiring. The only disadvantage of this method is the amount of work involved, in case S-02 is to be replaced for any reason. In some cases, it may not be possible to terminate S-02 directly on WTS. In this case, there will be a necessity to provide some intermediate termination arrangement. Here, care must be taken to select proper terminals, with following considerations
terminals are suitable for S-02 leads. temperature ratings of these terminals.
IMPORTANT PRECAUTIONS
Never install S-02 in HV winding coils. Avoid S-02 cable running parallel to power / high tension cables, S-02 cables should be grouped with other instrumentation cables. Tie S-02 lead wires properly and rigidly so that they are securely in place. The excess lead length should be accommodated in the marshalling box rather than in the transformer enclosure. Ensure S-02 leads are provided with end ferrules of right size. Never try to solder the free ends of the sensor leads. It is advisable to mount S-02 on the LV output side of the transformer. This would avoid the chance of accidental flash-over with HV. Always keep the S-02 sensors in their respective packing till they are installed. All spares or extra sensors should be handled in packed condition only.
25
OIL COOLED
FA Q
OIL COOLED
3. What is a thermal image and how does it help to estimate the winding temperature ?
Due to high voltages associated with the windings and due to insulation considerations, direct access to the windings for installing the temperature sensor is not possible. Therefore, indirect means of estimating this temperature has to be done. One of the most reliable methods to estimate winding temperature is by using THERMAL IMAGE formation technique. This image is formed digitally by our ( OTI&WTI ) models, by measuring top oil temperature & current flowing through the winding and doing calculations considering temperature gradient and time constant. And this image is displayed as Winding Temperature. The RTD sensor is installed on the transformer to measure Top Oil temperature. Winding current / load current is measured using a C.T. installed in the winding of the transformer. Temperature gradient ( dT ) and Thermal Time constant of windings are estimated by design consideration and set accordingly. Please note that the Thermal image gives the estimated winding temperature and is not actual.
CONTROL ROOM
4. What is the difference between Winding Temperature Scanner (WTS) & Normal Temperature Scanner?
WTS are built specially for transformer application & the features provided in this series of scanners are in line with the requirements of transformer industry. The operating conditions are more severe for equipments meant for transformer / switchyard application. The design for these scanners is more focused towards reliability, vibration handling, noise immunity, mounting ease, higher ambient temperatures etc. Normal temperature scanners are designed for control rooms where environmental conditions, are much less severe. This is the reason we call these temperature scanners as Transformer Protection Relays. At PECON, we manufacture products for both transformer as well as for control room application. We therefore insist and suggest our customers to use appropriate equipment for specific need and application.
DIMENSION
5. What features are essential for a Transformer protection relay (WTS, OTI&WTI) ?
For the safety, reliability & long operational life of a transformer, a good temperature surveillance system is necessary. A good temp. surveillance system should provide the following features: Accurate temperature measurements (windings, core, oil etc etc). Capability of warning the user of excessive transformer temperature (alarm). Capable of switching off and isolating the transformer from line in case the transformer reaches a limiting temperature level (trip). Cooling fan control. Alarm, trip and fan controls settable over operating range. Sensor Fault monitoring and indication. Maximum temperature registering. Signal for remote indication & data logging. Should be suitable for switchyard environmental conditions. All PECON winding temperature scanners ( Transformer protection relays ) are designed to meet these basic requirements. Most of them will have many additional features incorporated.
TECSYSTEM
APPLICATION NOTE
6. What is a RTD?
Resistance Temperature Detector or RTD for short, is a device whose resistance changes with temperature. Higher the temperature more the resistance. This change in resistance of these sensors allow us to measure the temperature.
26
Temp. Deg. C.
White
0.0 100.0
10.0 103.9
20.0 107.8
30.0 111.7
40.0 115.5
Resistance Ohms
All S-02s coming to you from PECON are checked and calibrated to international standards and traceable to national standards.
10. What type of wire leads should I use for extending RTDs to WTS?
DIMENSION APPLICATION NOTE TECSYSTEM Standard field cables (copper) of 1, 1.5 or 2.5 mm. (as per plant standard) can be used for RTD lead connections. It is recommended to keep RTD leads as small as possible to keep lead resistance errors minimum. Also, try to avoid intermediate joints and terminations. However, this distance in some installations can be as long as few hundred meters. With three wire leads extension, 250 meters of 1.5 mm extension leads will cause less than 1 C error. 2.5 mm wire would cause even lower errors.
27
CONTROL ROOM
OIL COOLED
OIL COOLED
3. What is a thermal image and how does it help to estimate the winding temperature ?
Due to high voltages associated with the windings and due to insulation considerations, direct access to the windings for installing the temperature sensor is not possible. Therefore, indirect means of estimating this temperature has to be done. One of the most reliable methods to estimate winding temperature is by using THERMAL IMAGE formation technique. This image is formed digitally by our ( OTI&WTI ) models, by measuring top oil temperature & current flowing through the winding and doing calculations considering temperature gradient and time constant. And this image is displayed as Winding Temperature. The RTD sensor is installed on the transformer to measure Top Oil temperature. Winding current / load current is measured using a C.T. installed in the winding of the transformer. Temperature gradient ( dT ) and Thermal Time constant of windings are estimated by design consideration and set accordingly. Please note that the Thermal image gives the estimated winding temperature and is not actual.
CONTROL ROOM
4. What is the difference between Winding Temperature Scanner (WTS) & Normal Temperature Scanner?
WTS are built specially for transformer application & the features provided in this series of scanners are in line with the requirements of transformer industry. The operating conditions are more severe for equipments meant for transformer / switchyard application. The design for these scanners is more focused towards reliability, vibration handling, noise immunity, mounting ease, higher ambient temperatures etc. Normal temperature scanners are designed for control rooms where environmental conditions, are much less severe. This is the reason we call these temperature scanners as Transformer Protection Relays. At PECON, we manufacture products for both transformer as well as for control room application. We therefore insist and suggest our customers to use appropriate equipment for specific need and application.
DIMENSION
5. What features are essential for a Transformer protection relay (WTS, OTI&WTI) ?
For the safety, reliability & long operational life of a transformer, a good temperature surveillance system is necessary. A good temp. surveillance system should provide the following features: Accurate temperature measurements (windings, core, oil etc etc). Capability of warning the user of excessive transformer temperature (alarm). Capable of switching off and isolating the transformer from line in case the transformer reaches a limiting temperature level (trip). Cooling fan control. Alarm, trip and fan controls settable over operating range. Sensor Fault monitoring and indication. Maximum temperature registering. Signal for remote indication & data logging. Should be suitable for switchyard environmental conditions. All PECON winding temperature scanners ( Transformer protection relays ) are designed to meet these basic requirements. Most of them will have many additional features incorporated.
TECSYSTEM
APPLICATION NOTE
6. What is a RTD?
Resistance Temperature Detector or RTD for short, is a device whose resistance changes with temperature. Higher the temperature more the resistance. This change in resistance of these sensors allow us to measure the temperature.
28
Quality Policy
PECON
We are commited to provide technologically superior products & high quality services to achieve total customer satisfaction. We commit ourselves to the highest standards of quality, integrity and excellence in all areas of business. We pledge to monitor our performance as an on-going activity and strive for continual improvement.