Vous êtes sur la page 1sur 3

DATA SHEET

Tellabs 8609 Smart Router


Modular access router with remarkable switching and interface capacity for LTE - coupled with extensive multiservice support
Tellabs Smart Routers
Tellabs Smart Routers offer versatile and scalable solutions for mobile backhaul from small aggregation sites to controller and gateway sites. In addition, Tellabs routers serve fixed and mobile convergence and cloud computing networking needs. The solutions are designed to meet the ever-growing requirements of data hungry mobile and enterprise users. All the Tellabs Smart Router platforms are LTE-ready and provide an extensive Ethernet and IP/MPLS feature set. Simultaneous support for multiservice applications in access and aggregation networks protects earlier network investments. The Smart Routers product family is supported by the Tellabs 8000 Intelligent Network Manager, which is an easy to use end-to-end network management solution. The Tellabs 8000 intelligent manager minimizes operational and maintenance costs and scales up to tens of thousands of network elements.

The Tellabs 8609 router has a packet-based forwarding architecture with QoS awareness.

Remarkable Throughput
Environmentally hardened, Tellabs 8609 router offers 12 fixed Gigabit Ethernet ports and two slots for interface modules providing throughput up to 7.5 Gbps. This makes the Tellabs 8609 router optimal for cell and aggregation sites.

Tellabs 8609 Smart Router Main Application


The Tellabs 8609 Smart Router provides a cost-efficient and seamless way of converting a mobile access network from an E1/ T1 TDM network to an Ethernet-based packet network without the need to update any of the radio access network equipment. Versatile service capabilities, including Ethernet, TDM, ATM and HDLC connectivity, IP VPN, MPLS switching, IP routing as well as VLAN switching enable the migration of 3G ATM and 2G TDM, Ethernet or IP-based networks into a single network infrastructure. The Tellabs 8609 router is ideal for access network cell sites that handle large amounts of mobile traffic. The Tellabs 8609 router is only 1RU in height, which enables installations at sites where rack space is limited.

Robust Synchronization
The Tellabs 8609 router supports a high quality OCXO, which provides improved temperature stability for IEEE 1588v2 and adaptive timing recovery. It also provides a highly stable node clock holdover. In addition to adaptive timing and IEEE 1588v2 clock recovery mechanisms, node timing can be obtained from a BITS or GPS source, any PDH, SONET/SDH interface or any of the synchronous Ethernet interfaces. The Tellabs 8609 router supports the transition from TDM to packet synchronization in a controlled way by verifying the packet synchronization performance with professional tools. As there is no longer a need for separate E1/T1s at every cell site, the Tellabs Smart Router solution provides a cost-optimized solution, which is independent from the legacy network.

Features and Benefits


The Tellabs 8609 router has a packet-based forwarding architecture with QoS awareness, enabling network optimization for voice, data services in LTE, 4G, 3G and 2G networks. The advanced quality of service features enable the differentiation of real-time voice and video services from premium and best effort data services. The unique Packet Loop Test feature, which is part of the Tellabs Smart Router product portfolio and Tellabs 8000 intelligent manager, helps to analyze delay, jitter, throughput and connectivity parameters.

See tellabs.com for more information about Tellabs Solutions

2 TELLABS 8609 ACCESS SWITCH

Specifications
Physical Dimensions n 441 x 44 x 300 mm / 17.36 x 1.73 x 11.81 in (W x H x D)
n

Line Modules (LM) n 8 x chE1/chT1 LM


n

8 x 10/100BASE-TX LM

Installation into standard 19-inch rack. The 23-inch and ETSI 600 mm racks supported with side adapters 1RU high

Resiliency n Ethernet Link Aggregation 802.1AX


n n n n

1:1 RSVP-TE LSP protection Fast Reroute (FRR) IP load balancing (Equal Cost Multipath - ECMP) TDM pseudowire redundancy

Power and Cooling n User-changeable dual feed wide range (-48 VDC to +24 VDC) power module (one per element)
n

Hot swappable single feed -48 VDC power module (up to 2 per element) Power consumption: typical 70W, maximum 100W Hot swappable air filter and fan module

n n

Synchronization n ITU-T [G.813] option 1


n n

ITU-T [G.8262] Telcordia [GR-1244] Stratum 3 Synchronous Ethernet SSM over Ethernet [G.8264] Adaptive synchronization from SAToP and CESoPSN pseudowires IEEE 1588v2 Precision Time Protocol IEEE1588v2 Boundary Clock for phase sync

Forwarding Plane n IPv4 routing


n

n n n n

MPLS switching (LSR and LER)

Functionality n IP VPN (RFC4364)


n n n n n n n n n

Ethernet/VLAN, SAToP, CESoPSN, ATM and HDLC pseudowires Single and multi-segment pseudowires TDM cross connection ATM VP/VC switching ATM cell concatenation ATM IMA MC / MLPPP, PPPmux Y.1731 frame loss, frame delay and frame delay variation support IEEE802.1ag Ethernet OAM loopback, continuity check, ping and link trace BFD (Static routes, OSPF, ISIS, RSVP-TE)

IPv4 Routing and MPLS Label Distribution Protocols n OSPF-TE, ISIS-TE, BGP and MP-BGP
n

LDP, RSVP-TE

Traffic Management n DiffServ support for up to 7 traffic classes, 7 queues per interface
n n n n n n

DiffServ aware MPLS Traffic Engineering (DS-TE) IEEE802.1P/Q mapping to IP or MPLS Policing and shaping VLAN shaping Access Control Lists (ACL) ATM service categories: CBR, rt-VBR, nrt-VBR, UBR+, UBR ATM VC queuing/shaping

Forwarding capacity n Up to 7.5 Gbps, typical 4 Gbps (packet size dependent) Chassis Configuration n Two slots for hot swappable power feed modules
n

Two slots for user-changeable Line Modules (LM) - Not hot swappable Twelve Fixed Gigabit Ethernet Ports: four 10BASE-T/100BASETX/1000BASE-T and eight 100/1000BASE-X SFP Local management port (RS-232 type) External alarm interface Station Clock Input (SCI) Station Clock Output (SCO) Pulse-per-Second (PPS) clock input and output

n n n n n

See tellabs.com for more information about Tellabs Solutions

3 TELLABS 8609 ACCESS SWITCH

Management n CLI with SSH2, FTP with SSH2


n n n

SNMPv1 and SNMPv2 monitoring Tellabs 8000 Intelligent Network Manager Cell site autoconfiguration based on DHCP client

Standards n Safety: EN 60950-1:2006 and IEC60950-1:2005


n n n

Next Step: Visit http://www.tellabs.com/solutions/ mobilebackhaul to access more data sheets, white papers and case studies on how Tellabs is helping operators advance their backhaul networks. If you have a question about Tellabs Mobile Backhaul solution, please email ask@tellabs.com.

EMC: EN 300 386:2008 RTTE Directive 1999/5/EC FCC 47 CFR Part 15, Subpart B, Class A

Environmental Conditions n Storage: ETSI EN 300 019-1-1, Class 1.1, Temperature: 5C to 45C / 23F to 113F
n

Transportation: ETSI EN 300 019-1-2 Class 2.3, Temperature: 40C to 70C / 40F to 158F Operating conditions: ETSI EN 300 019-1-3 Class 3.2 (non-condensing). Temperature: -40C to 65C / -40F to 149F. Relative humidity: 5% to 95% Minimum cold boot-up temperature: -20C / -4F

North America Tellabs 1415 West Diehl Road Naperville, IL 60563 U.S.A. +1 630 798 8800 Fax: +1 630 798 2000

Asia Pacific Tellabs 3 Anson Road #1401 Springleaf Tower Singapore 079909 Republic of Singapore +65 6215 6411 Fax: +65 6215 6422

Europe, Middle East & Africa Tellabs Abbey Place 2428 Easton Street High Wycombe, Bucks HP11 1NT United Kingdom +44 871 574 7000 Fax: +44 871 574 7151

Latin America & Caribbean Tellabs Rua James Joule No. 92 EDIFCIO PLAZA I So Paulo SP 04576-080 Brasil +55 11 3572 6200 Fax: +55 11 3572 6225

The following trademarks and service marks are owned by Tellabs Operations, Inc., or its affiliates in the United States and/or in other countries: TELLABS, TELLABS and T symbol, T symbol , and SMARTCORE. Statements herein may contain projections or other forward-looking statements regarding future events, products, features, technology and resulting commercial or technological benefits and advantages. These statements are for discussion purposes only, are subject to change and are not to be construed as instructions, product specifications, guarantees or warranties. Actual results may differ materially. The information contained herein is not a commitment, promise or legal obligation to deliver any material, code, feature or functionality. It is intended to outline Tellabs general product direction. The development, release and timing of any material, code, feature or functionality described herein remains at Tellabs sole discretion. 2013 Tellabs. All rights reserved. 74.2290E Rev. H 02/13