GE Consumer & Industrial

Power Protection

GE imagination at work

ns

tio

Es

sti

ed
lop

MCB's and RCCB's / RCBO's


for domestic installations

lly dev
a
i
c
e
pe

for dom

New
DMS-line

c installa

DMS-line
Compliant with domestic standards EN/IEC 60898-1 and EN/IEC 61008/9-1
Safety terminals:
protects the installer
by excluding all risks.
Safe installation ensured

Quality clips
Easy fixation on DIN rail
User friendly and reliable

Clear identification:
- Current rating - Tripping curve
- Interrupting capacity
- Selectivity class
- Product codification
- Laserprinting

Bistable & dynamic clips


Ensure easy and reliable fixations
Flat and pozidrive screwdrivers

RCCB
No unwanted tripping
Flat and flush mounted orange push-button

GE imagination at work

DMS-line
Abaco and Europe Line:
Insulated enclosures suited
for DMS-line installations

Strong and stable terminals

Torque

3.5 Nm

2007

2008

2009

2010

Time

High torque terminals


3.5 Nm for MCB's
4.5 Nm for RCCB's

High capacity terminals


25mm2 or 2 x 10mm2 for MCB's
35mm2 or 2 x 16mm2 for RCCB's
Fork connection possibilities

Protected terminals IP 20

BS

DMS-line
MCB's

EN/IEC 60898-1

4500
3

6000
3

MCB's - Characteristic C 4.5kA

In (A)

Cat. No.

Ref. No.

In (A)

Cat. No.

Ref. No.

Pack.

6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63

DG41 B06
DG41 B10
DG41 B16
DG41 B20
DG41 B25
DG41 B32
DG41 B40
DG41 B50
DG41 B63
DG42 B06
DG42 B10
DG42 B16
DG42 B20
DG42 B25
DG42 B32
DG42 B40
DG42 B50
DG42 B63
DG43 B06
DG43 B10
DG43 B16
DG43 B20
DG43 B25
DG43 B32
DG43 B40
DG43 B50
DG43 B63

690668
690669
690670
690671
690672
690673
690674
690675
690676
690677
690678
690679
690680
690681
690682
690683
690684
690685
690686
690687
690688
690689
690690
690691
690692
690693
690694

6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63

DG41 C06
DG41 C10
DG41 C16
DG41 C20
DG41 C25
DG41 C32
DG41 C40
DG41 C50
DG41 C63
DG42 C06
DG42 C10
DG42 C16
DG42 C20
DG42 C25
DG42 C32
DG42 C40
DG42 C50
DG42 C63
DG43 C06
DG43 C10
DG43 C16
DG43 C20
DG43 C25
DG43 C32
DG43 C40
DG43 C50
DG43 C63

690695
690696
690697
690698
690699
690700
690701
690702
690703
690704
690705
690706
690707
690708
690709
690710
690711
690712
690713
690714
690715
690716
690717
690718
690719
690720
690721

12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
4
4
4

MCB's - Characteristic B 6kA

MCB's - Characteristic C 6kA

In (A)

Cat. No.

Ref. No.

In (A)

Cat. No.

Ref. No.

Pack.

6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63

DG61 B06
DG61 B10
DG61 B16
DG61 B20
DG61 B25
DG61 B32
DG61 B40
DG61 B50
DG61 B63
DG62 B06
DG62 B10
DG62 B16
DG62 B20
DG62 B25
DG62 B32
DG62 B40
DG62 B50
DG62 B63
DG63 B06
DG63 B10
DG63 B16
DG63 B20
DG63 B25
DG63 B32
DG63 B40
DG63 B50
DG63 B63

690722
690723
690724
690725
690726
690727
690728
690729
690730
690731
690732
690733
690734
690735
690736
690737
690738
690739
690740
690741
690742
690743
690744
690745
690746
690747
690748

6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63

DG61 C06
DG61 C10
DG61 C16
DG61 C20
DG61 C25
DG61 C32
DG61 C40
DG61 C50
DG61 C63
DG62 C06
DG62 C10
DG62 C16
DG62 C20
DG62 C25
DG62 C32
DG62 C40
DG62 C50
DG62 C63
DG63 C06
DG63 C10
DG63 C16
DG63 C20
DG63 C25
DG63 C32
DG63 C40
DG63 C50
DG63 C63

690553
690554
690555
690556
690557
690558
690559
690560
690561
690569
690586
690570
690571
690572
690573
690574
690575
690576
690577
690578
690579
690580
690581
690582
690583
690584
690585

12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
4
4
4

Copyright GE Power Controls 2007

MCB's - Characteristic B 4.5kA

6-63A
230/400V
C
4.5kA / 6kA
3
2
25 or 2 x 10 mm
1, 2, 3
115g/pole

Ref. C/4525/E/EX 1.0 Ed. 01/07

Thermal setting In
Rated voltage AC Un
Tripping characteristic
Short-circuit capacity acc EN/IEC 60898-1
Selectivity class
Terminal capacity
Poles
Weight

40171

Performances

DMS-line

Thermal setting in
Residual Current Im
Rated voltage AC Un
Short-circuit capacity
Nuisance tripping resistance
Terminal capacity
Poles
Weight

40171

RCCB's
EN/IEC 61008-1 - Type AC
Performances
25 - 63A
30-300mA
2P: 230-400V
Inc = 6000A at 230V fuse 63A gG
AC: 250A 8/20s
35mm2 or 2 x 16mm2
2
2P: 210g

RCCB's - Type AC
In (A)
25
40
63
25
40
63
25
40
63
25
40
63

Cat. No.
DCG225/030
DCG240/030
DCG263/030
DCG425/030
DCG440/030
DCG463/030
DCG225/300
DCG240/300
DCG263/300
DCG425/300
DCG440/300
DCG463/300

Ref. No.
690776
690778
608413
608415
608417
608419
690777
690779
608414
608416
608418
608420

Pack.
6
6
6
6
6
6
6
6
6
6
6
6

RCBO's
EN/IEC 61009-1 - Type AC
Performances
Thermal setting in
Residual Current Im
Rated voltage AC Un
Short-circuit capacity
Nuisance tripping resistance
Terminal capacity
Poles
Weight

6 - 40A
30mA
2P: 230-400V
Inc = 6000A
AC: 250A 8/20s
35mm2 or 2 x 16mm2
2
2P: 210g

Cat. No.
DDM60C06/030
DDM60C10/030
DDM60C16/030
DDM60C20/030
DDM60C25/030
DDM60C32/030
DDM60C40/030

Ref. No.
690788
690789
690790
690791
690792
690793
690794

Pack.
6
6
6
6
6
6
6

Ref. C/4525/E/EX 1.0 Ed. 01/07

In (A)
6
10
16
20
25
32
40

Copyright GE Power Controls 2007

RCBO's - Type AC

GE POWER CONTROLS
International Sales
Nieuwevaart 51
B-9000 Gent - Belgium

Tel. +32/9 265 21 11


Fax +32/9 265 28 90
E-mail: gepcbel@gepc.ge.com