SECTION 07100 WATERPROOFING 00000000PART 1 - GENERAL 1.1 SECTION INCLUDES A. Sheet membrane waterproofing for the following: 1. 2. B. C.

General waterproofing for basement(s), toilets, washrooms, tearoom and other below grade areas as indicated on Drawings and specified herein. Planters boxes, Water tanks and Fountains.

Liquid waterproofing for vaults. Lining for the following: 1. 2. Water tanks and Fountains. Elevator pits.

1.2

REFERENCES A. ASTM - American Society for Testing and Materials ASTM D 471 Test Method for Rubber Property - Effect of Liquids ASTM D 570 Test Method for Water Absorption of Plastics ASTM D 638 Test Method for Tensile Properties of Plastics ASTM D 828 Test Method for Tensile Breaking Strength of Paper and Paperboard ASTM D 1004 Test Method for Initial Test Resistance of Plastic Film and Sheeting ASTM E 96 Standard Method of Test for Water Vapor Transmission of Materials

ASTM E 154 Test Method for Water Vapor Retarders Used in Contact with Earth under Concrete Slabs, on walls, or as Ground Cover 1.3 SUBMITTALS A. Submit product data, samples, general recommendations from manufacturer, for types of waterproofing required. Include data showing that materials comply with the specified requirements.

1.4

TRANSPORTATION, HANDLING AND STORAGE A. Deliver materials in manufacturer's unopened, labeled packing and in compliance with the manufacturer's storage, handling, installation and protection requirements.

1.5

WARRANTY
07100-1 Waterproofing

ITCC in Riyadh Residential Complex J10-13300

A.

Provide written warranty, agreeing to replace and repair defective materials and workmanship. Warranty includes responsibility for removal and replacement of other work which conceals sheet waterproofing. Warranty period is 10 years after date of substantial completion.

1.6

QUALITY ASSURANCE A. Manufacturer: Obtain primary waterproofing materials of each type required from a single manufacturer, to the greatest extent possible. Provide secondary materials only as recommended by manufacturer of primary materials.

1.7

JOB CONDITIONS A. B. Substrate: Proceed with waterproofing after completing substrate construction, openings and penetrating works. Weather: Proceed with waterproofing and associated works only when existing and forecast weather conditions permit work to be performed in accordance with manufacturer's recommendations and warranty requirements.

PART 2 - PRODUCTS 2.1 0WATERPROOFING MATERIALS A. Sheet Membrane Waterproofing: High performance APP (Atactic Polypropylene) modified bitumen reinforced membranes produced from a blend of special polypropylene thermoplastic polymers and distilled bitumen and reinforced with 200 g/m non-woven polyester fabric, complying with the following requirements: Softening Point: 155oC as per ASTM D 36 Penetration at 25oC: 20 - 30 dmm as per ASTM D 5 Heat Resistance, 2 hours at 120 oC: No flow Tensile Strength: * Longitudinal: 23 kN/m as per ASTM D 828 * Transverse: 15.8 kN/m as per ASTM D 146 * * Elongation: Longitudinal: 55 percent as per ASTM D 828 Transverse: 60 percent as per ASTM D 146

Tear Resistance: * Longitudinal: 195 N per DIN 53859 * Transverse: 210 N as per DIN 53859 Puncture Resistance: 1155 N as per ASTM E 154 Water Absorption: Less than 0.12 percent as per ASTM D 570 and ASTM D 471 Water Vapor Transmission: Less than 0.28 g/m2/24 hrs as per ASTM E 96, Procedure E (37.8oC at 90% RH)

ITCC in Riyadh Residential Complex J10-13300

07100-2

Waterproofing

Water Permeability of Membrane at Seamed Joint: Absolutely impermeable

Waterproofing membrane shall be applied in accordance with the following: 1. Horizontal and Vertical Waterproofing Applications for Basement, fountains, potable and non-potable water tanks, elevator and sump pits and other areas below grade as shown on Drawings: Membrane shall be applied in 2 layers, fully bonded torch applied to the primed substrate as follows: a. b. 2. First Layer: 4 mm thick, black finish. Second Layer: 3 mm thick, black finish.

Wet Areas (Kitchens, Tea Room, Toilets and Wash Areas): Single membrane (one layer) with minimum thickness of 4 mm, fully bonded, torch applied to the primed substrate.

B.

00Planter boxes: Double membrane (two layers) fully bonded torch applied to the primed substrate as follows: 1. First Layer: 3 mm thick, black finish with fine talcum on one side and a torchoff polyethylene foil fixed to the other side and contains a special anti-root chemical additive. Second Layer: 3 mm thick, finish with mineral granules on the top side and a thin torch-off polyethylene foil fixed to the other side and contains a special anti-root chemical additive.

2.

C.

Lining for Potable Water Tanks: 1. A two-component epoxy resin based, non-toxic, seamless, high build solventfree waterproof coating suitable for potable water applications and applied in two coats, 200 micron thick each, with glass-fiber reinforcement grade 110 g/m (between coats) on the internal surfaces of the tank as per written recommendations of lining Manufacturer. OR 2. A two-component epoxy polysulphide, non-toxic, seamless, solvent-free waterproof coating suitable for potable water applications and applied in total DFT of 500 micron on the internal surfaces of the tank as per written recommendations of lining Manufacturer. Material shall comply with BS 6920 with following characteristics: Tensile Strength @ 23o C to BS 903:A2 Elongation at Break @ 23o C to BS 903:A2 Adhesion to substrate to BS EN 24624 Concrete Steel Hardness to BS 2782 Part 3 : 7 MPa, minimum : 20%, minimum : >1 MPa : >2 MPa : 52 Shore D

D.

Lining For Fountain: 1. A single component pitch modified polyurethane coating conforming to ASTM C 836 or BS 3900 applied in a single coat, 1.3 mm thick on the internal
07100-3 Waterproofing

ITCC in Riyadh Residential Complex J10-13300

surfaces as per the recommendations of the lining manufacturer and suitable for ceramic tile application. E. 0Lining for Sewer Manholes: 1. A three-component system consisting of epoxy resin without solvents and chemical resistant fillers applied in 2 coats, 300 microns thick each on internal surfaces unless recommended otherwise by the lining Manufacturer. Lining shall be trowel-applied to the substrate.

2.2

MISCELLANEOUS MATERIALS A. B. Primer for Application to Concrete Surfaces: As recommended by the roofing membrane manufacturer complying with ASTM D 41. Protection Board: Provide minimum 2.5 mm thick multi-layer pressure bonded board with asphaltic impregnation as a protection for the waterproofing where indicated on the Drawings. Separation Layer: Non-woven polyester fabric, minimum density of 180 g/m and to be laid above the membrane where shown on Drawings. Vapor Barrier: Polyethylene sheeting conforming to ASTM D 4397, minimum 200 microns thick having a vapor permeance rating not exceeding 0.063 perms, and shall be laid with 300 mm overlapping.

C. D.

PART 3 - EXECUTION 3.1 INSTALLATION A. General: Waterproofing works shall be executed by a specialized Sub-Contractor recommended by the waterproofing and/or lining manufacturer and approved by the Engineer. Comply with waterproofing and/or lining manufacturer's recommendations regarding installation details, surface preparation, and torch applied process, priming of surfaces as well as the overlapping. Substrate shall be smooth, hard dry and free from high spots and depressions. Substrate shall be swept clean and free from dust, loose cement scale, oil, grease, foreign substances and debris. Starting at the low point of the slab, apply the waterproofing membrane loose laid for horizontal areas with minimum 50 mm overlap. All the joints shall be welded with hot air. Lay non-woven polyester fabric separation layer over waterproofing membrane prior to application of other finishing. On vertical areas, apply the waterproofing membrane mechanically fixed to walls with minimum 50 mm overlap. Use waterproofing manufacturer's standard fasteners with PVC covering for welding to the membrane. All the joints shall be welded with hot air. Apply protection board prior to backfilling. Test the work after completion by water flooding to a minimum height of 75 mm for a period of 48 hours.
07100-4 Waterproofing

B.

C.

D.

E.

F.

ITCC in Riyadh Residential Complex J10-13300

G. H.

For the application of waterproof lining and liquid waterproofing, follow manufacturer's written instructions. Submit 10 years guarantee for the waterproofing works done and the associated works covering the failure of materials or workmanship. Guarantee shall be signed by waterproofing Sub-Contractor and shall indicate which (Contractor or SubContractor) has assumed the responsibility for the removal and the replacement of the works concealing the waterproofing work in case of failure of material or workmanship. END OF SECTION

ITCC in Riyadh Residential Complex J10-13300

07100-5

Waterproofing