Autodesk Robot Structural Analysis Professional 2011

Pinned column base design


Ratio

Eurocode 3: EN 1993-1-8:2005/AC:2009 + CEB Design Guide: Design of fastenings on concrete


0.35

General
Connection no.: Connection name: 6 Pinned column base

Geometry
Column
Section: Lc = Material: UC 305x305x97 5 S355 [m] Column length

Column base
lpd = bpd = tpd = Material: fypd = fupd = STEEL 43-245 245 430 [MPa] [MPa] Resistance Yield strength of a material 350 350 16 [mm] [mm] [mm] Length Width Thickness

Anchorage
Class = fyb = fub = d= nV = nH = eH = eV = 8.8 640 800 20 2 2 150 100 [mm] [mm] [MPa] [MPa] [mm] Anchor class Yield strength of the anchor material Tensile strength of the anchor material Bolt diameter Number of bolt columns Number of bolt rows Horizontal spacing Vertical spacing

Wedge
Section: lw = Material: fyw = IPE 100 100 STEEL 43-245 245 [MPa] Resistance [mm] Length

Material factors
M0 = M2 = C = 1 1.25 1.5 1200 1200 900 [mm] [mm] [mm] Partial safety factor Partial safety factor Partial safety factor Spread footing length Spread footing width Spread footing height

Spread footing
L= B= H= Concrete Class fck = Grout layer tg = fck,g = Cf,d =

C15 15 [MPa] Characteristic resistance for compression

30 12 0.3

[mm] [MPa]

Thickness of leveling layer (grout) Characteristic resistance for compression Coeff. of friction between the base plate and concrete

Welds
ap = 4 [mm] Footing plate of the column base

aw =

[mm]

Wedge

Loads
Case: Nj,Ed = Vj,Ed,y = Vj,Ed,z = Manual calculations. -326.72 23.28 82.43 [kN] [kN] [kN] Axial force Shear force Shear force

Results
Compression zone
COMPRESSION OF CONCRETE c= fjd = Fc,Rd,n = RESISTANCES OF SPREAD FOOTING IN THE COMPRESSION ZONE Nj,Rd = Fc,Rd,n Nj,Rd = 1279.74 [kN] Resistance of a spread footing for axial compression [6.2.8.2.(1)] [mm] [MPa] [kN] Additional width of the bearing pressure zone [6.2.5.(4)] Design bearing resistance [6.2.5.(7)] Bearing resistance of concrete for compression [6.2.8.2.(1)]

32 20 1279.74

Connection capacity check


Nj,Ed / Nj,Rd 1,0 (6.24) 0.26 < 1.00 verified -0.26

Shear
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE F1,vb,Rd,y = F1,vb,Rd,z = SHEAR OF AN ANCHOR BOLT F2,vb,Rd = Fv,Rd,sm = CONCRETE PRY-OUT FAILURE Fv,Rd,cp = CONCRETE EDGE FAILURE Fv,Rd,c,y = Fv,Rd,c,z = SPLITTING RESISTANCE Ff,Rd = BEARING PRESSURE OF THE WEDGE ONTO CONCRETE Fv,Rd,wg,y = Fv,Rd,wg,z = SHEAR CHECK Vj,Rd,y = nb*min(F1,vb,Rd,y,F2,vb,Rd,Fv,Rd,sm,Fv,Rd,cp,Fv,Rd,c,y) + Fv,Rd,wg,y + Ff,Rd Vj,Rd,y = Vj,Ed,y / Vj,Rd,y 1,0 0.07 < 1.00 349.72 [kN] verified Connection resistance for shear -0.07 CEB [9.3.1]

275.2 275.2

[kN] [kN]

Resistance of an anchor bolt for bearing pressure [6.2.2.(7)] onto the base plate Resistance of an anchor bolt for bearing pressure [6.2.2.(7)] onto the base plate

49.86 27.93

[kN] [kN]

Shear resistance of a bolt - without lever arm [6.2.2.(7)] Shear resistance of a bolt - with lever arm CEB [9.3.1]

178.81

[kN]

Concrete resistance for pry-out failure

CEB [9.3.1]

202.75 211.85

[kN] [kN]

Concrete resistance for edge failure Concrete resistance for edge failure

CEB [9.3.1] CEB [9.3.1]

98.02

[kN]

Slip resistance

[6.2.2.(6)]

140 77

[kN] [kN]

Resistance for bearing pressure of the wedge onto concrete Resistance for bearing pressure of the wedge onto concrete

Vj,Rd,z = nb*min(F1,vb,Rd,z,F2,vb,Rd,Fv,Rd,sm,Fv,Rd,cp,Fv,Rd,c,z) + Fv,Rd,wg,z + Ff,Rd Vj,Rd,z = Vj,Ed,z / Vj,Rd,z 1,0 Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z 1,0 0.29 < 1.00 0.35 < 1.00 286.72 [kN] verified verified Connection resistance for shear -0.29 -0.35 CEB [9.3.1]

Welds between the column and the base plate


= = yII = zII = W = / (fu/M2)) 1.0 (4.1) 0.07 < 1.00 (2 + 3.0 (yII2 + 2)) / (fu/(W*M2))) 1.0 (4.1) < 1.00 0.12 (2 + 3.0 (zII2 + 2)) / (fu/(W*M2))) 1.0 (4.1) < 1.00 0.20 24.67 24.67 4.84 37.18 0.85 verified verified verified [MPa] [MPa] [MPa] [MPa] Normal stress in a weld Perpendicular tangent stress Tangent stress parallel to Vj,Ed,y Tangent stress parallel to Vj,Ed,z Resistance-dependent coefficient -0.07 -0.12 -0.2 [4.5.3.(7)] [4.5.3.(7)] [4.5.3.(7)] [4.5.3.(7)] [4.5.3.(7)]

Weakest component:
FOUNDATION - BEARING PRESSURE ONTO CONCRETE

Remarks
Anchor curvature radius is too small. 50 [mm] < 60 [mm] Segment L4 of the hook anchor is too short. 0 [mm] < 100 [mm]

Connection conforms to the code