Description

A specific procedure must be used when replacing one of the internal disks in a
system with internal fibre drives (Sun Fire[TM] 280R, Sun Fire[TM] V480, Sun
Fire[TM] V490, Sun Fire[TM] V880, Sun Fire[TM] V890), especially if the disk is
under Veritas Volume Manager (VxVM) control.

Although these disks are hot-swappable, the procedure below should be used to
alert VxVM to the fact that the drive is being replaced. This document applies to
Veritas Volume Manager (VxVM) 3.x and above. This document also assumes that you
are running either:

Solaris[TM] 8, 9 or 10 Operating System(OS),


Solaris[TM] 7 OS, with kernel patch 106541-08 or higher.

This is required to get the functionality of the devfsadm command.

Failure to follow this procedure could result in a duplicate entry for the
replaced disk in VxVM. This is most notable when running a 'vxdisk list' command.

For example:

# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c1t0d0s2 sliced rootdisk rootdg online
c1t1d0s2 sliced - - error
c1t1d0s2 sliced - - error

The extra device will disappear after the next reboot, which seems to be the only
way to remove it. Therefore, it is best to prevent the duplicate device from being
created in the first place. This is accomplished by the following procedure. Steps
9a - 9c pertain only to Sun[TM] Cluster 3.x installations.

If the disk is not under VxVM control, you can skip steps 2,4,9-11

Steps to Follow

NOTE: All data on these devices should have been backed up.

Before replacing any disk under VxVM control, it should be in either a 'failed' or
'removed' state:

# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c1t0d0s2 sliced rootdisk rootdg online
c1t1d0s2 sliced - - online
- - disk01 rootdg failed was:c1t1d0s2

If the disk does not show up as "failed was", as shown above, then you should run
'vxdiskadm' and choose option #4 to remove the disk for replacement. After running
'vxdiskadm', the output should look like this:

# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c1t0d0s2 sliced rootdisk rootdg online
c1t1d0s2 sliced - - online
- - disk01 rootdg removed was:c1t1d0s2

NOTE:
If this is a root-disk or root-mirror, check the following removed disk
information, before this operation. This information is needed to change nvramrc.

* WWN

For example,

# ls -al /dev/rdsk/c1t0d0s0
lrwxrwxrwx 1 root root 74 Mar 6 2003 c1t0d0s0 -> ../../
devices/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfa19920,0:a,raw

* devalias and boot-device in nvramrc

For example,

# eeprom nvramrc

devalias rootdisk /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w2100004cfa19920,0:a


devalias mirrdisk /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w2100004cfa19838,0:a

boot-device=rootdisk mirrdisk

1. If this is a root-disk or root-mirror, use the dumpadm command to ensure


that the dump-device is not on the failed disk. If it is, move it to the
good side of the mirror, for example:

dumpadm -d /dev/dsk/c1t0d0s1

2. If vxdiskadm option 4 is used to remove the disk for replacement, instruct


VxVM to re-read the device tree by running the command

# vxdctl enable

3. Put the disk into the "offline" state with the following command:

# vxdisk offline c1t1d0s2

4. Verify the disk has been marked "offline" with "vxdisk list":

# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c1t0d0s2 sliced rootdisk rootdg online
c1t1d0s2 sliced - - offline
- - disk01 rootdg removed was:c1t1d0s2

5. Once Veritas has recognized the disk as offline and ready for replacement,
you need to tell the operating system. This is done as follows:

# /usr/sbin/luxadm remove_device /dev/rdsk/c1t1d0s2

This will produce output similar to the following:


WARNING!!! Please ensure that no file systems are mounted on these device(s).

All data on these devices should have been backed up.

The list of devices which will be removed is:

1: Device name: /dev/rdsk/c1t1d0s2 Node WWN: 20000020371b1f31


Device Type: Disk device
Device Paths: /dev/rdsk/c1t1d0s2
Please verify the above list of devices and then enter c or <CR> to
Continue or q to Quit. [Default: c]:c
stopping: /dev/rdsk/c1t1d0s2.... Done
offlining: /dev/rdsk/c1t1d0s2.... Done
The drives are now off-line and spun down.
Physically remove the disk and press the Return key.

Hit <Return> after removing the device(s).

<date> <systemname> picld[87]: Device DISK1 removed


Device: /dev/rdsk/c1t1d0s2
No FC devices found. - /dev/rdsk/c1t1d0s2

NOTE: The picld daemon notifies the system that the disk has been removed.

If no errors are printed, continue to step 6.

Otherwise, if you receive any errors during this step:

* physically pull the bad disk from the host

* run the commands:

# vxdisk rm c1t1d0s2
# luxadm -e offline /dev/rdsk/c1t1d0s2

* if the disk is multipathed, run the 'luxadm -e offline' on the second path
as well.

6. Initiate devfsadm cleanup subroutines by entering the following command:

# /usr/sbin/devfsadm -C -c disk

The default devfsadm operation, is to attempt to load every driver in the


system, and attach these drivers to all possible device instances.
The devfsadm command then creates device special files in the /devices
directory, and logical links in /dev.

With the "-c disk" option, devfsadm will only update disk device files. This
saves time and is important on systems that have tape devices attached.
Rebuilding these tape devices could cause undesirable results on non-Sun
hardware.

The -C option cleans up the /dev directory, and removes any lingering
logical links to the device link names.

This should remove all the device paths for this particular disk. This can
be verified with:
# ls -ld /dev/dsk/c1t1d*

This should return no devices.

7. Verify that the reference to this disk is gone by running the commands

# vxdisk list (if the disk is under vxvm control)


# format

It is now safe to physically replace the disk.

8. After replacing the disk, create the necessary entries in the Solaris OS
device tree with one of the following commands:

# devfsadm

or

# /usr/sbin/luxadm insert_device <enclosure_name,sx>

where sx is the slot number.

NOTE: In many cases, luxadm insert_device does not require the enclosure
name and slot number.

Use the following to find the slot number:

# luxadm display <enclosure_name>

To find the <enclosure_name> use:

# luxadm probe

Run "ls -ld /dev/dsk/c1t1d*" to verify that the new device paths have been
created.

NOTE: After inserting disk and running devfsadm(or luxadm), the old ssd id
was changed to a new one. So, just ignore this change.

For example:
When an error occurs on the following disks(ssd3).

WARNING: /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfa19920,0 (ssd3):


Error for Command: read(10) Error Level: Retryable
Requested Block: 15392944 Error Block: 15392958

(After inserting disk)

picld[287]: [ID 727222 daemon.error] Device DISK0 inserted


qlc: [ID 686697 kern.info] NOTICE: Qlogic qlc(2): Loop ONLINE
scsi: [ID 799468 kern.info] ssd10 at fp2: name w21000011c63f0c94,0, bus
address ef
genunix: [ID 936769 kern.info] ssd10 is /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@
w21000011c63f0c94,0
scsi: [ID 365881 kern.info] <SUN72G cyl 14087 alt 2 hd 24 sec 424>
genunix: [ID 408114 kern.info] /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000011c
63f0c94,0 (ssd10) online
9. Label the disk using the format command.

If the disk is under VxVM control, be sure to write an SMI label(Solaris 9


4/03 OS or later):

# format -e /dev/rdsk/c1t1d0s2
...
format> l
[0] SMI Label
[1] EFI Label
Specify Label type[1]: 0
Auto configuration via format.dat[no]? no
Auto configuration via generic SCSI-2[no]? yes
Ready to label disk, continue? yes

If the disk is not under VxVM control, label the disk to local requirements,
otherwise, it could be labeled with a standard vtoc.

Steps 9a - 9c are only required if this is a system running SunCluster

For Pre SunCluster 3.2

9a. /usr/cluster/bin/scdidadm -C

9b. /usr/cluster/bin/scdidadm -r

9c. /usr/cluster/bin/scgdevs

For SunCluster 3.2

9a. /usr/cluster/bin/cldevice clear *run on each node, or use "-n <node,...> to


specify nodes

9b. /usr/cluster/bin/cldevice refresh *run on each node, or use "-n <node,...> to


specify nodes

9c. /usr/cluster/bin/cldevice populate *run on any node

Note: It's possible to get errors from c0t0d0 which is the cdrom/dvd drive on Sun
fire v480,v880 etc..

10. Instruct VxVM to re-read the device tree by running the command

# vxdctl enable

11. The disk will remain in the "offline" state until the new disk is
initialized.

To initialize it, use the command line first:

# vxdisksetup -i c1t1d0

Then, use 'vxdiskadm' and choose option #5 to replace the failed or removed
disk.

- OR -

Run 'vxdiskadm' and choose option #5 to initialize it and replace the


failed or removed disk. If the 'vxdiskadm' command is run, and option #5
is chosen, it will show that "Access is disabled" for this new disk
(because it is still "offline"), and will be asked whether or not you wish
to "enable access" to it. Answer 'yes' to this question.

12. The disk should now be online and functional, within the operating system
and VxVM. Confirm this with "vxdisk list".

NOTE: Do not re-boot the system and Setp-13(modify nvramrc) until a


synchronization is completed. If it is re-booted, it cannot boot from
a new disk or modify devalias. Confirm this with "vxtask list":

# vxtask list

13. If a swap partition had to be moved, move it back, for example:

dumpadm -d /dev/dsk/c1t1d0s1

14. If this was a root-disk or a root-mirror, then you need to make sure and run
/etc/vx/bin/vxbootsetup command. The vxbootsetup utility configures a disk by
writing a boot track at the beginning of the disk and by creating physical disk
partitions in the UNIX VTOC that match the mirrors of the root, swap, /usr and
/var.

/etc/vx/bin/vxbootsetup -g rootdg rootdisk

15. If this was a root-disk or root-mirror, then ensure the nvram aliases are
updated so you can boot.

ls -al /dev/rdsk/<new disk>s0


example: ls -al /dev/rdsk/c1t1d0s0

Check the WWN from the ls output with the appropriate root alias entries in
the NVRAM. (eeprom nvramrc) and look at rootmirror or rootdisk entries.

NOTE: The change method of devalias in nvramrc.


From removed disk information to new disk information.

For example,

- List before modifying nvramrc.


(removed disk information)

# eeprom nvramrc

devalias rootdisk
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w2100004cfa19920,0:a
devalias mirrdisk
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w2100004cfa19838,0:a

- List the new disk information

# ls -al /dev/rdsk/c1t0d0s0
lrwxrwxrwx 1 root root 74 Mar 6 2003 c1t0d0s0 ->
../../
devices/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000011c63f0c94,0:a,raw

- Modify nvramrc
(This example is written in the bourne shell)

# eeprom nvramrc='devalias root-disk


/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@
w21000011c63f0c94,0:a[enter]
devalias rootmirror
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfa19838,0:a'[enter]

- List after modifying nvramrc.

# eeprom nvramrc
devalias rootdisk
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000011c63f0c94,0:a
devalias mirrdisk
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w2100004cfa19838,0:a

NOTE:
If this is a root-disk or rootmirror, the device path contains the WWN of the
new disk. It is necessary to update the nvramrc devalias entries to the new
device path, so the system will be able to boot from the newly-replaced rootdisk
or rootmirror.

Product

VERITAS Volume Manager 3.0.2 Software


Sun Fire 280R Server
Sun Fire V880 Server
Sun Fire V480 Server
VERITAS Volume Manager 4.0 Software
VERITAS Volume Manager 3.5 Software
VERITAS Volume Manager 3.2 Software

VERITAS Volume Manager 3.1 Software


VERITAS Volume Manager 3.0.4 Software
VERITAS Volume Manager 3.2 for Solaris 9
Solaris Cluster 3.2
Sun Cluster 3.1
Sun Cluster 3.0
Sun Fire V880z Visualization Server
Sun Fire V890 Server
Sun Fire V490 Server
VERITAS Volume Manager 4.1 Software

Document Audience: SPECTRUM


Document ID: 204286
Old Document ID: (formerly 40842)
Title: Veritas Volume Manager - Procedure to Replace Internal FibreChannel
(FC) Disks controlled by VxVM
Copyright Notice: Copyright © 2009 Sun Microsystems, Inc. All Rights Reserved
Update Date: Fri Jun 06 00:00:00 MDT 2008

Vous aimerez peut-être aussi