T-P1 TRIFSICO(Tablero de proteccin) 12 CTOS

TRAMO

C1-L1

DEMANDA

4,380

BALANCE DE FASES
R
2,190

I MAX
T

2,190

CONDUCTORES

DUCTERIA

DESCRIPCIN

PROTECCIN

[A]

I para el calcula del


conductor NTC 2050

21.1

26.3

4xN8 +1xN10T

1" pvc T/P

3x30 A, 10 kA

TCON

0.0

0.0

2xN12 +1xN12T

1/2" pvc T/P

1x20 A, 10 kA

Tomas

0.0

0.0

2xN12 +1xN12T

1/2" pvc T/P

1x20 A, 10 kA

Iluminacin baos y entrenamiento

Cu THWN

[A]

Reserva
Reserva
Reserva
Reserva
Reserva
Reserva
Reserva
N de
salidas

2,190

2,190
4,380

11.495

14.4

3xN6F+1N6N

11/2 " PVC

3x40 A, 25 kA

Acometida

TCON TRIFSICO(Tablero de control iluminacin cancha)


N

BALANCE DE FASES

Circuito
60

645

645

860

TCON-1*2

430
1,290

TCON-3*4

1,720

TCON-5*6

1,720

TCON-7*8

1,720

860

TCON-9*10

1,720

860

TCON-11*12

1,290

TCON-13*14
TCON-15
N de
salidas

76

4
5

304

860

152

22

9,460

3,377

3,162
10,064

Cu THWN

PROTECCIN

DESCRIPCIN

[A]

5.9

7.3

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

7.8

9.8

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

860

7.8

9.8

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

7.8

9.8

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

860

7.8

9.8

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

645

5.9

7.3

2xN10 +1xN12T

3/4" EMT

2x20 A, 10 kA

Iluminacin cancha central

1.4

1.7

2xN10 +1xN12T

3/4" pvc T/P

2x20 A, 10 kA

Iluminacin exterio

300

2.5

3.1

2xN12 +1xN12T

1/2" pvc T/P

1x20 A, 10 kA

Iluminacin tarima

3,525

26.411

33.0

4xN8 +1xN10T

1" PVC

3x30 A,25 kA

Acometida TCON

152

300

DUCTERIA

860
860
645

I para el calcula del


conductor NTC 2050

CONDUCTORES

[A]

I MAX
T

CALCULO DE CARGA DIVERSIFICADA


Cargas
Carga W
Motobombas
0
Total de cargas especiales
0
Resto de la carga:
4,161
Total de cargas
4,161

F.P

Carga VA
0.85
1.00

0
0
4,161
4,161

CALCULO DE ACOMETIDA Y PROTECCIN GENERAL


Especificacin de acometida general:
Tipo de aislamiento
Calibre AWG por fase y para neutro
Ducto de Acometida

THHN
6 AWG
11/2" PVC

Proteccin:
Breaker

CALCULO DE REGULCIN PARA ACOMETIDA PRINCIPAL


CARGA [kVA]:
4.16
DISTANCIA [M]:
62
CONDUCTOR:
[Cu, THWN 6]
K:
0.0031232 [codensa]
REGULACIN [%]:
0.806

3x40 A

calibre

I Nominal

4/0
2/0
1/0
2
4
6
8

320
175
150
115
85
65
50

0.00048176
0.00070927
0.00086474
0.00130761
0.00201401
0.0031232
0.00492117

Tension
factor de
potencia

KG Baja tension
0.80

0.85

0.90

0.95

1.00

14

752.23500

797.34040

842.141

866.377

927.36

12
10
8
6
4
2
1

476.46700
302.87700
196.46300
126.25400
81.99970
53.85660
44.28230

504.46560
320.14810
207.16110
132.67170
85.74950
55.93171
45.74010

532.18
337.154
217.607
134.8855
89.2797
57.8007
46.9888

559.367
353.67
227.585
144.602
92.4032
59.2879
47.8501

583.52
367.36
234.87
147.84
93.184
58.576
46.48

1/0
2/0
3/0
4/0
250
350
500
750
1000

36.36970
30.06020
25.04900
21.01200
18.34900
14.57420
11.92120
9.65586
8.50015

37.37117
30.70733
25.41483
21.15945
18.40482
14.43523
11.61412
9.24226
8.03776

38.1696
31.1578
25.5891
21.1208
18.2864
14.1286
11.139
8.66627
7.41674

38.592
31.244
25.4085
20.7374
17.8453
13.5115
10.3527
7.78946
6.50182

36.848
29.232
23.184
18.368
15.5456
11.1059
7.7759
5.18
3.8942

Tension
factor de
potencia

8
6
4
2
1
1/0
2/0
3/0
4/0

KG Baja tension (ALUMINIO AISLADO)


0.80

332.61000
217.07000
146.78000
101.50000
84.89000
71.82000
61.36000
52.77000
46.22000

0.85

332.61000
217.07000
146.78000
101.50000
84.89000
71.82000
61.36000
52.77000
46.22000

Tension
factor de
potencia

8
6
4
2
1
1/0

0.90

364.97
235.18
156.53
106
87.53
73.02
61.47
52.01
44.86

0.95

379.4
242.66
159.9
106.82
87.46
72.27
60.21
50.35
42.94

1.00

386.4
243.04
156.5
101.2
81.1
65.4
53
42.9
35.4

KG Baja tension (ACSR)


0.80

326.97000
220.02000
148.91000
104.87000
88.79000
75.94000

0.85

342.75700
229.31500
153.84900
107.02000
89.93500
76.33300

0.90

357.79
237.89
158.08
108.45
90.38
76.02

0.95

371.46
245.14
161.01
108.58
89.49
74.42

1.00

377.2
244.8
156.5
101.2
81.1
65.4

2/0
3/0
4/0

65.41000
56.60000
49.22000

65.26000
56.02900
48.44300

Tension
factor de
potencia

4
2
1
1/0
2/0
3/0
4/0

4
2
1
1/0
2/0
3/0
4/0

62.32
52.35
44.5

53
42.9
35.4

KG MEDIA TENSION (13,2 kV)


0.80

156.11000
112.07000
95.19900
83.14000
72.61000
63.80000
56.42000

0.85

0.90

160.16340
113.33500
96.25000
82.64740
71.57490
62.34430
54.75780

Tension
factor de
potencia

64.42
54.79
47.04

0.95

163.31
113.68
95.59
81.25
69.45
60.02
52.27

1.00

164.76
112.33
93.23
78.17
66.07
56.09
48.25

156.5
101.2
81.1
65.4
53
42.9
35.4

KG MEDIA TENSION (34,5 kV)


0.80

156.62000
112.58000
96.50000
63.65000
73.12000
64.31000
56.93000

0.85

160.61200
113.78300
96.69800
83.09580
72.02330
62.79300
55.21000

0.90

163.68
114.05
95.96
81.62
70.02
60.4
52.64

0.95

185.03
112.6
93.5
78.43
66.34
56.36
48.52

1.00

156.5
101.2
81.1
65.4
53
42.9
35.4

Calibre

2
1/0
2/0
4/0
250
350
500

Resistencia de
alterna en
(ohm/km)

Reactancia
inductiva
(Ohm/km)

0.6671
0.4195
0.3331
0.2103
0.1651
0.1191
0.0853

0.17
0.155
0.149
0.138
0.133
0.128
0.121

Impeda
0.8

0.63568
0.4286
0.35588
0.25104
0.21188
0.17208
0.14084

Impedancia eficaz
0.85

0.9

0.95

0.656588057
0.438226317
0.36162562
0.251451011
0.210397097
0.168663184
0.136245705

0.674491282
0.445112934
0.364737594
0.249422805
0.206563356
0.162983906
0.129512677

0.686827483
0.446923734
0.362970235
0.242875486
0.198374237
0.153112987
0.118817238

0.6671
0.4195
0.3331
0.2103
0.1651
0.1191
0.0853

Vous aimerez peut-être aussi