Vous êtes sur la page 1sur 5

OUTLINED SPECIFICATIONS PROJECT: LOCATION: OWNER: ITEM NO.

I PROPOSED TWO- STOREY RESIDENCE W/ ATTIC AND DECK TUYO BALANGA CITY, BATAAN ATTY & MRS. DENTE ILAYA PARTICULARS GENERAL REQUIREMENTS 1. Mobilization/Demobilization SPECIFICATIONS Moving in of the necessary manpower, tools equipment at site for the start of construction & thereafter moving out of all these upon completion of the project. Clearing of the site from all unnecessary plants, garbage and other things that may hamper in the construction. Construction of batter boards to establish the buildings line & grade. Construction of temporary fence enclosing the site, bunkhouse and toilet for all stayin workers, filed office for all concerned project personnel, bodega for storage of materials and provision of electrical & water connections all of which to be dismantled and removed from the site upon completion of the project.

2. Site Clearing

3. Staking & Layout

4. Temporary Facilities

II

EARTHWORKS 1. Excavation

All column footings & wall footings shall be excavated to the desired depth and all such structures shall in no case rest on fill. Excavated soil shall be backfilled with thorough compaction upon concreting of footings and other sub- grade structures. All area with elevated floor lines shall be filled with selected borrow fill materials and shall be thoroughly compacted layer by layer. Provision of 0.05 meter thick (min) gravel bedding with compaction as base for all footings & slab on fill. Application of chlordance or equivalent soil poisoning material properly diluted with water poured into the ground surfaces here footings and slab on fill shall rest.

2. Backfilling & Construction

3. Earthfilling & Compaction

4. Gravel Filling & Compaction

5. Soil Treatment

III

CONCRETE WORKS 1. Concrete

20.685 MPa (3000 psi) concrete strength at 28 days using jobstite mixed concrete for all footings, columns, beams, stair and suspended slab and 17.24 MPa (2500 psi) concrete strength for slab on fill.

2. Steel Reinforcing Bars

275.8 MPa (44000 psi) tensile yield strength of deformed bars for 12 mm and above and 227.5 MPa (33000 psi) for 10 mm and below. Using 12mm thick form plywood applied with form oil at side in contact with concrete and for frame & scaffoldings using a combination of good lumber and coco lumber.

3. Formworks & Scaffoldings

IV

WALLS & WALL FINISHES 1. Exterior Walls

Using 150 mm thick non-load bearing CHB with 10 mm vertical &horizontal rebars at 0.60 m.o.c. Using 100 mm thick non-load bearing CHB with 10 mm vertical &horizontal rebars at 0.60 m.o.c. 12 mm thick (min.) to w5 mm thick plain cement plaster finish. Using 200 mm x 300 mm imported glazed wall tiles up to the ceiling line with a single line accent samples of which were approved by the owner. Using pre- cast moulding along lower edge and cast in place moulding along upper and vertical edges. Using from 25 mm x 100 mm Tanguile, kiln dried along all corners of wall & flooring except T & B.

2. Interior Walls

3. Exterior & Interior Finishing of Wall Except Toilet & Bath 4. Toilet & Bath Wall

5. Exterior Window Casting

6. Baseboard

FLOOR & FLOOR FINISHES 1. Balcony, Foyer, Living, Dining and Kitchen

Using 300 mm x 300 mm floor tiles for exterior sample of which was approved the owner. Plain cement finish. Using 200 mm x 200 mm floor tiles whose shade shall match the walls as verbally agreed with the owner. 30 mm to 400 mm thick concrete topping with plain cement finish.

2. Bedrooms 3. Toilet& Bath

4. Second Floor

VI

CEILING & CEILING FINISHES 1. Living and Dining, Kitchen & All Bedrooms 2. Balcony & Eaves

Using 12 mm thick Gypsum board on metal framing. Using 12 mm thick Fibercement board on metal framing. Using from 25 mm x 75 mm wooden cornice at T & B area and from 25 mm x 100 mm at all other areas. Using open web angular steel trusses as

3. Ceiling Cornice

VII

STRUCTURAL STEEL ROOF

FRAMING

main frame anchored on 10 mm thick base plate with 16 mm anchor bolts, Ga. 16 mm x 50 mm x 100 mm cee purling with 12 mm sag rods all of wich conforming to ASTM- A36. Using Ga. 26 stile roof profile, Ga 26 ridge cap and Spanish gutter.

VIII

PRE- PAINTED LONG SPAN G.I. ROOFING & ACCESSORIES DOORS AND WINDOWS 1. Main Door

IX

using from 50 mm x 150 mm Narra door jamb and solid Narra panel door with carving design. Molded panel with rectangular shaped designs on 50 mm x 150 mm Tanguile floor jamb, kiln dried. Using PVC hollow core flush door and jamb. Using Tanguile panel door. French type window frame using Z- bar, Ibar and T- bar with 4.5 mm thick clear glass.

2. Bedrooms Door

3. T & B Doors

4. Exit Door at Kitchen 5. Windows at Living, Dining, Bedrooms, T & B and Kitchen

MISCELANEOUS HARDWARE 1. Door Hinges

Using 75 mm x 75 mm brass plated, loose pin, butterfly hinges or equivalent. Using Schlage with double lock made in US or equivalent. Using Schlage orbit type. Ordinary barrel bolt to be used for doors @ water closet enclosure. Shall be used at upper and lower corners of sliding door.

2. Main Door Lockset

3. Bedroom Locksets 4. Barrel Bolt

5. Flush Bolt

XI

OTHER FINISHING WORKS 1. Main Kitchen Counter

Concrete granite countertop and 100 mm splashboard over which shall be 200 mm x 200 mm glazed tiles up to the bottom of overhead cabinet. Concrete with 200 mm x 200 mm tile finish including the splashboard. Using solid wood with design for doors and for the other parts using moistureresistant melamine laminated boards. Same as base cabinet Using melamine laminated boards as shown and approved by the Owner. Using 50 mm x 300 mm solid Tanguile.

2. Dirty Kitchen Counter

3. Kitchen Base Cabinet

4. Kitchens Overhead Cabinet 5. Pantry Cabinet 6. Stairs Steps Finish

7. Stairs Risers Finish 8. Stairs Railing and Handrail

Using 12 mm thick plywood. Using from 75 mm x 100 mm Tanguile kiln dried Handrail and from 50 mm x 50 mm baluster railing.

XII

WATERROOFING WORKS 1. T & B

Using three (3) coats of Weathercoat by brush applications.

XIII

PLUMBING WORKS 1. Plumbing Works

Using PVC pipes and fittings, Netlex or equivalent, Sch. 40, S- 6000 for sanitary & vent lines and PPR pipes & fittings. Using Kohler brand for water closets, bath tub and lavatory fixtures. Single and double bowl kitchen sink shall be stainless of imported brand including their goose neck faucets and other accessories. Using 75 mm PVC pipes and fittings, Netlex or equivalent, Sch. 40, S- 1000. Using 150 mm and up non- reinforced concrete pipes with mortar jointing. 0.40 m x 0.60 m deep CHB catch basins with concrete base and cover. Construction of 1.50 m wide by 2.50 m long by 1.50 m deep two- chambered septic tank using 150 mm thick non- load bearing CHB with vertical & horizontal rebar and with reinforced concrete base and cover

2. Plumbing Fixtures

3. Downspout

4. Drainage Line

5. Catch Basins

XIV

SEPTIC VAULT

XV

ELECTRICAL WORKS 1. Electrical Conduits

Using PVC pipes & fittings by Netlex or equivalent. Using Ga. 16; G.I., deep type. Using National brand or equivalent. Using stranded wire, Phelps Dodge or equivalent. Using brand manufactured by duly accredited supplier and in accordance with the electrical code of the Philippines. Using fluorescent bulbs and pinlights by G.E. or equivalent.

2. Utility Boxes, Junction Boxes 3. Wiring Devices 4. Wires and Cables

5. Panel Boards and Circuit Breakers

6. Lighting Fixtures

XVI

PAINTING WORKS 1. Concrete Wall and Ceiling

Using gloss latex by roller application, Boysen brand. Using flat wall enamel by roller

2. Wooden Ceiling

application, Boysen brand. 3. Doors and Jambs Except Main Door 4. Main Door & Jamb All painted with enamel by Boysen brand.

Natural Varnish, Boysen brand or equivalent. Enamel paint by brush application, Boysen brand. All varnish with same color/shade to match the laminated flooring.

5. Steel Railings, Window and Grilles and Sliding Doors 6. Baseboard, Cornice Casting, Stair Handrail and Balluster

Vous aimerez peut-être aussi