Vous êtes sur la page 1sur 594

Z ZT TE E G GS SM M W WL LL L S SY YS ST TE EM M

ZX G1 0

GSM W LL SYSTEM

Operation Manual
OF

ZXG10-BSC (V2) Vol . 2

SH E NZHE N, CH INA

Operation Manual of ZXG10-BSC (V2)-Vol 2

Table of Contents
1
1.1 1.2 1.2.1 1.2.2 1.3 1.3.1 1.3.2 1.4 1.4.1 1.4.2 1.4.3 1.4.4 1.5 1.5.1 1.5.2 1.5.3

Man-machine Commands ...........................................................................1


Overview of man-machine commands .....................................................................1 Security management ............................................................................................3 Man-machine commands for user management .......................................................3 Man-machine commands of operation logs ............................................................ 17 Alarm management .............................................................................................. 20 Man-machine commands of alarm management .................................................... 20 Man-machine commands for test management .................................................... 104 Performance management ................................................................................. 113 Man-machine commands of measurement jobs ................................................... 113 Man-machine commands of observation jobs....................................................... 120 Man-machine commands of alarm threshold ........................................................ 124 Other man-machine commands .......................................................................... 132 Configuration management ................................................................................. 135 Man-machine commands of radio resources management ................................... 135 Man-machine commands of software loading....................................................... 259 Man-machine commands of integrated configuration management........................ 287

2
2.1 2.2 2.2.1 2.2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.4 2.4.1 2.4.2 2.5 2.5.1 2.5.2 2.5.3 2.5.4 A.1 A.1.1 A.1.2 A.2 A.2.1 A.2.2 A.2.3 A.2.4 A.2.5 A.2.6 A.2.7 A.2.8 A.2.9 A.2.10 A.2.11 A.2.12 A.2.13

Operation .....................................................................................................471
Overview........................................................................................................... 471 Security management ........................................................................................ 472 User management ............................................................................................. 472 Operation log ..................................................................................................... 475 Configuration management ................................................................................. 478 Radio resource management .............................................................................. 478 Software loading ................................................................................................ 483 Dynamic data management ................................................................................ 488 Integrated configuration management ................................................................. 494 Fault management ............................................................................................. 499 Alarm management ............................................................................................ 499 Test management .............................................................................................. 504 Performance management ................................................................................. 507 Performance management ................................................................................. 507 Performance analyzer ........................................................................................ 511 Invoke tracing .................................................................................................... 513 Signaling tracing ................................................................................................ 516 BTS performance measurement counter ............................................................. 520 Power control counter ........................................................................................ 520 Paging counter .................................................................................................. 521 RMM performance measurement counter............................................................ 522 Radio access counter ......................................................................................... 522 SDCCH counter................................................................................................. 524 SAPI3 counter ................................................................................................... 525 TCH/F counter ................................................................................................... 527 TCH/H counter................................................................................................... 532 RMM assignment counter ................................................................................... 536 RMM call drop counter ....................................................................................... 538 Radio measurement counter ............................................................................... 541 Handover reason counter ................................................................................... 543 General counter of handover .............................................................................. 546 RMM queue counter........................................................................................... 553 Handover synchronization mode counter............................................................. 555 Paging counter .................................................................................................. 555
Page I of II

Appendix A Performance measurement counter .....................................................520

Operation Manual of ZXG10-BSC (V2)-Vol 2

A.2.14 A.2.15 A.2.16 A.3 A.3.1 A.3.2 A.3.3 A.3.4 A.3.5 A.3.6 A.3.7 A.4 A.5 A.5.1 A.5.2 A.6 A.6.1 A.6.2 A.6.3 A.7 A.7.1 A.7.2 A.8 A.8.1 A.8.2 A.8.3

Abis interface message counter .......................................................................... 555 Radio resources availability counter .................................................................... 557 Counters for generating the report forms required by the National Telecommunications Bureau .............................................................................................................. 558 SMM performance measurement counter definition .............................................. 565 BSSMAP message counter................................................................................. 565 A interface message counter............................................................................... 568 SCCP connection counter................................................................................... 568 SMM assignment counter ................................................................................... 569 SMM handover counter ...................................................................................... 569 SMM call drop counter........................................................................................ 570 Land resource availability counter ....................................................................... 571 LAPD counter .................................................................................................... 571 Signaling No.7 counter ....................................................................................... 572 SCCP unit counter ............................................................................................. 572 SCCP composite counter ................................................................................... 574 Gb interface counter........................................................................................... 574 NS sub-layer counter.......................................................................................... 574 BSSGP counter ................................................................................................. 576 Paging performance measurement counter ......................................................... 579 BSS counter ...................................................................................................... 583 Traffic statistic counter........................................................................................ 583 Resource management counter .......................................................................... 584 Other counters ................................................................................................... 587 RMM load counter.............................................................................................. 587 Service load counter .......................................................................................... 588 SMM Load counter............................................................................................. 588

Appendix B Acronyms ....................................................................................................589

Page II of II

Operation Manual of ZXG10-BSC (V2)-Vol 2

1
1.1

Man-machine Commands
Overview of man-machine commands
The man-machine commands of this system begin with a command code and end with a semicolon. The contents between the command code and the semicolon are the parameters representing specific information. A command code consists of 4 letters. Among them, the first letter defines the subfunction area of the command, and is called level 1 code. The second and the third letters represent the action or effect object type of the command, and are called level 2 codes. The last letter defines the action to be executed by the command, and is called level 3 code. The parameter part consists of one or more parameter blocks. All parameter blocks use separator : as the start symbol, and the position of a parameter block cannot be changed. The parameters include the following types: 1. Type Boolean The value of the type Boolean data can be T (TRUE) or F (FALSE). 2. Numerical value type Numerical values are classified into Integer type and Floating type. The integer type is classified into integers in a general sense (without containing any separators) and integer-type PARAMETER ARGUMENTs (such separators as &, &&, -, &- and &&- can appear in the parameter, and on both sides of these symbols are integers). The floating type is classified into floating numbers in a general sense (without containing any separators) and floating-type PARAMETER ARGUMENTs (separator & can appear in the parameter, and on both sides of this symbol are floating numbers).

Page 1 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Identifier type Including basic identifier type (identifiers in a general sense, a combination of letters and numbers that begins with a letter) and identifier-type PARAMETER ARGUMENT ( separator & can appear in the parameter, and on both sides of the separator are identifiers). 4. Enumerated type Including the enumerated type in a general sense (various enumerated items are separated with separator ,) and enumerated-type PARAMETER ARGUMENT ( & can appear in the parameter, and on both sides of the separator are enumerated-type data ). 5. Date type The format of the date-type parameter: YYYY-MM-DD. 6. Time type Including second-order time type (the format of the second-order time type parameter: HH-MM-SS) and minute-order t i me type (the format of the minute-order time type parameter: HH-MM), etc. 7. Temperature type Decimal floating number +suffix C. 8. Percent type Decimal floating number + suffix % . 9. Character string type Including the character strings in a general sense (a combination of characters between a pair of double quotation marks) and characterstring-type PARAMETER ARGUMENT (& can appear in the parameter, and on both sides of the symbol are general character strings).
Page 2 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2
1.2.1 1.2.1.1

Security management
Man-machine commands for user management SGAQ 1. Command function To query the authority of a user group for a specific operation. 2. Syntax structure SGAQ: GRPNAME, OPCODE; 3. Parameter description 1) GRPNAME: user group name. Identifier type. 2) OPCODE: operation code. Identifier type.

1.2.1.2

SGDA 1. Command function To add an operation object to a user group. 2. Syntax structure SGDA: GRPNAME, OPCODE, AddOBJ; 3. Parameter description 1) GRPNAME: user group name. Identifier type, no default value. 2) OPCODE: operation code. Identifier type, no default value. 3) AddOBJ: operation object. Character string, no default value.

Page 3 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2.1.3

SGDD 1. Command function To delete an operation object from a user group . 2. Syntax structure SGDD: GRPNAME, OPCODE, RMOBJ; 3. Parameter description 1) GRPNAME: user group name. Identifier type, no default value. 2) OPCODE: operation code. Identifier type, no default value. 3) RMOBJ: operation object. Character string, no default value.

1.2.1.4

SGDQ 1. Command function To query the direct authority of a user group. 2. Syntax structure SGDQ: GRPNAME; 3. Parameter description GRPNAME: user group name. Identifier type.

1.2.1.5

SGOQ 1. Command function To query the authority of a user group for a specific operation. .

Page 4 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure SGOQ: GRPNAME, OPCODE; 3. Parameter description 1) GRPNAME: user group name. Identifier type. 2) OPCODE: operation code. Identifier type. 1.2.1.6 SGPQ 1. Command function To query the authority of a user. 2. Syntax structure SGPQ: GRPNAME; 3. Parameter description GRPNAME: user group name. Identifier type. 1.2.1.7 SGRA 1. Command function To modify the role of a user group . 2. Syntax structure SGRA: GRPNAME, ADDROLE, RMROLE; 3. Parameter description 1) GRPNAME: user group name. Identifier type, no default value.

Page 5 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) ADDROLE: the role to be added. Identifier type, no default value. 3) RMROLE: the role to be deleted. Identifier type, no default value. 1.2.1.8 SGRC 1. Command function To create a user group. 2. Syntax structure SGRC: GRPNAME, NOTE, WINRIGHT; 3. Parameter description 1) GRPNAME: user group name. Identifier type, no default value. 2) NOTE: brief description of the user group. Character string type. 3) WINRIGHT: activating right of client window. Numerical value type. An integer between 0 and 255. Each bit represents a window activation right. 1.2.1.9 SGRD 1. Command function To delete one or more user groups. 2. Syntax structure SGRD: GRPNAME; 3. Parameter description GRPNAME: user group name. Composite identifier type, no default value.

Page 6 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2.1.10

SGRM 1. Command function To modify the attribute of a user group . 2. Syntax structure SGRM: GRPNAME, NOTE, WINRIGHT; 3. Parameter description 1) GRPNAME: user group name. Identifier type, no default value. 2) NOTE : brief description of the user group. Character string type. 3) WINRIGHT: activating right of client window. Numerical value type. An integer between 0 and 255. Each bit represents a window activation right.

1.2.1.11

SGRQ 1. Command function To query the attribute of a user group . 2. Syntax structure SGRQ: GRPNAME; 3. Parameter description GRPNAME: user group name. Identifier type, the default value is ALL.

1.2.1.12

SLUC 1. Command function To create a user.


Page 7 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure SLUC: USERNAME, PASSWD1, PASSWD2 [, NOTE ]; 3. Parameter description 1) USERNAME: user name. Identifier type, no default value. 2) PASSWD 1: user password. Character string type, more than 6 characters with letters and numbers, no default value. 3) PASSWD 2: confirming user password. Character string type, no default value. 4) NOTE: a brief description of the user. Character string type. 1.2.1.13 SOBQ 1. Command function To query all operation objects of a specific operation. 2. Syntax structure SOBQ: OPCODE, tLEVEL; 3. Parameter description 1) OPCODE: operation code. Identifier type. 2) TLEVEL: level of the management object. Integer type. 1.2.1.14 SOPQ 1. Command function To query all operation lists.

Page 8 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure SOPQ: ; 3. Parameter description None. 1.2.1.15 SRAQ 1. Command function To query the direct right of a role for a specific operation. 2. Syntax structure SRAQ: ROLENAME, OPCODE; 3. Parameter description 1) ROLENAME: role name. Identifier type. 2) OPCODE: operation code. Identifier type. 1.2.1.16 SRDA 1. Command function To add an operation object to a role. 2. Syntax structure SRDA: ROLENAME, OPCODE, ADDOBJ; 3. Parameter description 1) ROLENAME: role name. Identifier type, no default value.

Page 9 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) OPCODE: operation code. Identifier type, no default value. 3) ADDOBJ: operation object. Character string, no default value. 1.2.1.17 SRDD 1. Command function To delete an operation object from a role . 2. Syntax structure SRDD: ROLENAME, OPCODE, RMOBJ; 3. Parameter description 1) ROLENAME: role name. Identifier type, no default value. 2) OPCODE: operation code. Identifier type, no default value. 3) RMOBJ: operation object. Character string, no default value. 1.2.1.18 SRDQ 1. Command function To query all rights of a role. 2. Syntax structure SRDQ: ROLENAME; 3. Parameter description ROLENAME: role name. Identifier type.

Page 10 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2.1.19

SRGQ 1. Command function To query the role of a user group . 2. Syntax structure SRGQ: GRPNAME; 3. Parameter description GRPNAME: user group name. Identifier type, no default value.

1.2.1.20

SRLC 1. Command function To create a role . 2. Syntax structure SRLC: ROLENAME, NOTE; 3. Parameter description 1) ROLENAME: role name. Identifier type, no default value. 2) NOTE: a brief description of the role. Character string type.

1.2.1.21

SRLD 1. Command function To delete one or more role. 2. Syntax structure

Page 11 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

SRLD: ROLENAME; 3. Parameter description ROLENAME: role name. Composite identifier type, no default value. 1.2.1.22 SRLM 1. Command function To modify the attribute of a role. 2. Syntax structure SRLM: ROLENAME, NOTE; 3. Parameter description 1) ROLENAME: role name. Identifier type, no default value. 2) NOTE: a brief description of the role. Character string type. 1.2.1.23 SRLQ 1. Command function To query the attribute of a role. 2. Syntax structure SRLQ: ROLENAME; 3. Parameter description ROLENAME (Role Name): role name. Identifier type, the default value is ALL.

Page 12 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2.1.24

SROQ 1. Command function To query the right of a role for a specific operation. 2. Syntax structure SROQ: ROLENAME, OPCODE; 3. Parameter description 1) ROLENAME: role name. Identifier type. 2) OPCODE: operation code. Identifier type.

1.2.1.25

SRPQ 1. Command function To query all rights of a role. 2. Syntax structure SRPQ: ROLENAME; 3. Parameter description ROLENAME: role name. Identifier type.

1.2.1.26

SRRA 1. Command function To modify a role. 2. Syntax structure

Page 13 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

SRRA: ROLENAME, ADDROLE, RMROLE; 3. Parameter description 1) ROLENAME: role name. Identifier type, no default value. 2) ADDROLE: the role to be added. Identifier type, no default value. 3) RMROLE: the role to be deleted. Identifier type, no default value. 1.2.1.27 SRRQ 1. Command function To query the attribute of a role. 2. Syntax structure SRRQ: ROLENAME; 3. Parameter description ROLENAME: role name. Composite identifier type, the default value is ALL. 1.2.1.28 SUGA 1. Command function To add a user to a user group. 2. Syntax structure SUGA: USERNAME, GRPNAME, BTIME, ETIME; 3. Parameter description 1) USERNAME: user name. Identifier type.
Page 14 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) GRPNAME: user group name. Identifier type. 3) BTIME: beginning time. Time type hh-mm-ss. 4) ETIME: ending time. Time type hh-mm-ss. 1.2.1.29 SUGD 1. Command function To add a user to a user group. 2. Syntax structure SUGD: USERNAME, GRPNAME; 3. Parameter description 1) USERNAME: user name. Identifier type. 2) GRPNAME: user g roup name. Identifier type. 1.2.1.30 SUGQ 1. Command function To query the group of a user. 2. Syntax structure SUGQ: USERNAME; 3. Parameter description USERNAME: user name. Identifier type.

Page 15 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.2.1.31

SUPQ 1. Command function To query the authority of a user. 2. Syntax structure SUPQ: USERNAME; 3. Parameter description USERNAME: user name. Identifier type.

1.2.1.32

SUSD 1. Command function To delete one or multiple users. 2. Syntax structure SUSD: USERNAME; 3. Parameter description USERNAME: user name. Identifier type, no default value.

1.2.1.33

SUSM 1. Command function To modify the attribute of a user. 2. Syntax structure SUSM: USERNAME, OLDPASS, PASSWD1, PASSWD2;

Page 16 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) USERNAME: user name. Identifier type, no default value. 2) OLDPASS: old password. Identifier type. 3) PASSWD 1: user password. Character string type, more than 6 characters, with letters and numbers. 4) PASSWD 2: confirming user password. Character string type. 1.2.1.34 SUSQ 1. Command function To query one or more OMCR users. 2. Syntax structure SUSQ: USERNAME; 3. Parameter description USERNAME: user name. Identifier type, the default value is ALL. 1.2.2 1.2.2.1 Man-machine commands of operation logs LCTQ 1. Command function To query the total number of operation logs that match the condition. 2. Syntax structure LCTQ: USERNAME, tERMID, OPCLASS, STATUS, ONDATE, ONTIME, ENDDATE, ENDTIME;

Page 17 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) USERNAME: user name. Character string type, the maximum length of the character string is 20. The default value is ALL, representing all users. 2) TERMID : terminal identifier. Signless integer, value range: 0~255, the default value is 0, representing all terminals. 3) OPCLASS: operating class. Character string type, the maximum length of the character string is 20. The default value is ALL, representing all operating classes. The existing supported operation classes include: alarm management, test management, equipment management, radio resources, signaling No.7, software loading, configuration management, performance management, performance analysis and security management. 4) STATUS: operation status. Enumerated type, value range: FAIL, SUCCEED, UNEND, ALL; the default value is ALL. 5) ONDATE: beginning date . Date type. The default value is 1990-01-01. The beginning data must be later than 1990-01-01. 6) ONTIME: beginning time. Second-order time type. The default value is 00-00-00. 7) ENDDATE: ending date . Date type. The default value is 2038-01-01. The ending data must be earlier than 2038-01-01. 8) ENDTIME: ending time. Second -order time type. The default value is 00-00-00. 1.2.2.2 LOGD 1. Command function To delete all operation logs. 2. Syntax structure

Page 18 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

LOGD; 3. Parameter description None. 1.2.2.3 LRDQ 1. Command function To query all operation logs that match the condition. 2. Syntax structure LRDQ: USERNAME, tERMID, OPCLASS, STATUS, ONDATE, ONTIME, ENDDATE, ENDTIME; 3. Parameter description Refer to the Parameter Description of command LCTQ. 1.2.2.4 LRDS 1. Command function To save the currently queried logs as another file (this command is not supported at present). 2. Syntax structure LRDS: FILENAME; 3. Parameter description FILENAME: file name. Character string type, the default value is oplog, representing to save the currently queried logs into file oplog.

Page 19 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3
1.3.1 1.3.1.1

Alarm management
Man-machine commands of alarm management AAAA 1. Command function This command is used to synchronize current alarms between the background and the foreground . 2. Syntax structure AAAA: BSCID, ModuleNo, MaxMpAid; 3. Parameter description 1) BSCID: the foreground BSC ID number. Signless integer, value range: 1~255. 2) ModuleNo: the module number of the foreground BSC. Signless integer, value range: 1~64. 3) MaxMpAid: the maximum identification number of the foreground alarm. Signless integer, value range: the minimum value is 0.

1.3.1.2

AAIV 1. Command function This command is used to immediately dump one or more specified alarms. 2. Syntax structure AAIV: ALMIDS; 3. Parameter description

Page 20 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ALMIDS: the identification numbers of the alarms to be dumped. Composite signless integer, value range: 1~4.3E+09. 1.3.1.3 AARQ 1. Command function This command is used to query alarms. 2. Syntax structure AARQ: QryType, AlmObj, {AlmCode, AlmCls}[, BgnDay][, BgnTime][, EndDay][, EndTime][, Flag]; 3. Parameter description 1) QryType: for selecting the current alarm and historical alarm. Signless integer, value range: 0~2. 2) AlmObj: for specifying the alarm source. Character string type. 3) AlmCode: for specifying the alarm code. Composite signless integer, value range: 0~65535. 4) AlmCls: for specifying the alarm class. Composite signless integer, value range: 1~4. 5) BgnDay: starting date for querying. Date type. 6) BgnTime: starting time for querying. Time type. 7) EndDay: ending date for querying. Date type. 8) EndTime: ending time for querying. Time type. 1.3.1.4 AASV 1. Command function
Page 21 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command is used to manually dump historical alarms. 2. Syntax structure AASV{: SaveDay}; 3. Parameter description SaveDay: for selecting the starting point of the historical alarms to be dumped. Signless integer, value range: 30~180. 1.3.1.5 ABCQ 1. Command function This command is used to query the status of a board. 2. Syntax structure ABCQ: {EBSCID, EBSCName, }RackNo, ShelfNo, SlotNo; 3. Parameter description 1) EbscID: for specifying the BSCID of the query task. Signless integer, value range: 1~255. 2) EbscName: for specifying the BSC Name of the query task. Character type. 3) RackNo: for specifying the rack No. of the board to be queried. Signless integer, value range: 1~15. 4) ShelfNo: for specifying the shelf No. of the board to be queried. Signless integer, value range: 1~6. 5) SlotNo: to specify the slot No. of the board to be queried. Signless integer, value range: 1~27.

Page 22 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.6

ACAQ 1. Command function This command is used to query the source alarm of a specified correlation alarm and the correlation rule for generating this correlation alarm.. 2. Syntax structure ACAQ: ALARMID; 3. Parameter description ALARMID: the identification number of the correlation alarm to be queried. Signless integer, value range: 1~4.3E+09.

1.3.1.7

ACBM 1. Command function This command is used to set the clock reference of CKI by specifying the SYCK board. 2. Syntax structure ACBM: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): CLKBASE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): the BSC ID number of the board for setting the clock reference. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for setting the clock reference. Character string type. 3) RACKNO (Rack No): the rack number of the board for setting the clock reference. Signless integer, value range: 1~15.
Page 23 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) SHELFNO (Shelf No): the shelf number of the board for setting the clock reference. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the board for setting the clock reference. Signless integer, value range: 1~27. 6) CLKBASE: the clock reference of CKI. Signless integer, value range: 0~15. 1.3.1.8 ACMM 1. Command function This command is used to set the clock mode of a specified SYCK board. 2. Syntax structure ACMM: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): CLKMODE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): the BSC ID number of the board for setting the clock reference. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for setting the clock reference. Character string type. 3) RACKNO (Rack No): the rack number of the board for setting the clock reference. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the board for setting the clock reference. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the board for setting the clock reference. Signless integer, value range: 1~27.

Page 24 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) CLKMODE: clock mode. Signless integer, value range: 1~5. Among them, : 1: automatic running state of SYCK board; 2: memory holding state ; 3: tracing state; 4: fast capture state; 5: free running state. 1.3.1.9 ACNA 1. Command function This command is used to confirm a specified current notification message. 2. Syntax structure ACNA: NOTIIDS; 3. Parameter description NOTIIDS: the identification number of the notification message to be confirmed. Composite signless integer, value range: 1~4.3E+09. 1.3.1.10 ACUA 1. Command function This command is used to confirm a specified current alarm. 2. Syntax structure ACUA: ALMIDS; 3. Parameter description ALMIDS (Alarm Identifications): the identification number of the alarm to be confirmed. Composite signless integer, value range: 1~4.3E+09. 1.3.1.11 ACUR 1. Command function

Page 25 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command is used to manually clear (restore) a specified current alarm. 2. Syntax structure ACUR: ALMIDS; 3. Parameter description ALMIDS (Alarm ID): the identification number of the alarm to be cleared. Composite signless integer, value range: 1~4.3E+09. 1.3.1.12 AEAQ 1. Command function This command is used to query all environmental alarm parameters. 2. Syntax structure AEAQ; 3. Parameter description None. 1.3.1.13 AIAM 1. Command function This command is used to set infrared alarm for a specified BSC, including the type (periodic, aperiodic), status (activated, shutdown) and disabling period of the infrared alarm. 2. Syntax structure AIAM: {EBSCID, EBSCNAME}, MODULENO: PERIOD, RLSTATUS, BGNDAY, BGNTIME, ENDDAY, ENDTIME;
Page 26 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number for setting infrared alarm. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias for setting infrared alarm. Character string type. 3) MODULENO (Module No): the module number for setting infrared alarm. Signless integer, value range: 1~64. 4) PERIOD (Period): type of the infrared alarm. Signless integer, value range: 0, 1. Among them, : 0: periodical infrared alarm; 1: infrared alarm in a specified period 5) RLSTATUS (Infrared Status): status of the infrared alarm. Signless integer, value range: 0, 1. Among them, : 0: activated; 1: shutdown. 6) BGNDAY (Begin Day): the beginning date for the effective period of the infrared alarm. Date type, the default value is NULL. 7) BGNTIME (Begin Time): the beginning time for the effective period of the infrared alarm. Second-order time type, the default value is NULL. 8) ENDDAY (End Day): the ending date for the effective period of the infrared alarm. Date type, the default value is NULL. 9) ENDTIME (End Time): the ending time for the effective period of the infrared alarm. Second-order time type, the default value is NULL. 1.3.1.14 AMTM 1. Command function This command is used to set periodic changeover for a specified M P board. 2. Syntax structure
Page 27 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

AMTM: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): CHOVTIME; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the MP board to be set. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the MP board to be set. Character string type. 3) RACKNO (Rack No): rack No. of the board to be set. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): shelf No. of the board to be set. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): slot No. of the board to be set. Signless integer, value range: 1~27. 6) CHOVTIME (Change Over Time): changeover time. Second-order time type. 1.3.1.15 AMTS 1. Command function This command is used to cancel periodic changeover for a specified MP board. 2. Syntax structure AMTS: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the MP board for canceling periodic changeover. Signless integer, value range: 1~255.
Page 28 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): the BSC alias of the MP board for canceling periodic changeover. Character string type. 3) RACKNO (Rack No): rack No. of the MP board for canceling periodic changeover. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): shelf No. of the MP board for canceling periodic changeover. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): slot No. of the MP board for canceling periodic changeover. Signless integer, value range: 1~27. 1.3.1.16 ANAC 1. Command function This command is used to set the main node alarm of a specified site under a specified BSS. 2. Syntax structure ANAC: EBSSID{, ESITEID, ESITENM}, RACKID: TMPNO; 3. Parameter description 1) EBSSID (BSS Equipment ID): the BSS ID number of the site to be set. Signless integer, value range: 1~255. 2) ESITEID (Site Equipment ID): the ID number of the site to be set. Signless integer, value range: 1~1024. 3) ESITENM (Site Equipment Name): the alias of the site to be set. Character string type. 4) RACKID (Rack ID): the ID number of the rack to be set. Signless integer, value range: 1~4.

Page 29 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) TMPNO (Template NO): the template number of the main node alarm to be set. Signless integer, value range: 1~16. 1.3.1.17 ANAM 1. Command function This command is used to modify the main node alarm setting of a specified site under a specified BSS. 2. Syntax structure ANAM: EBSSID, {ESITEID, ESITENM}, RACKID: TMPNO; 3. Parameter description 1) EBSSID (BSS Equipment ID): the BSS ID number of the site for modification. Signless integer, value range: 1~255. 2) ESITEID (Site Equipment ID): the ID number of the site for modification. Signless integer, value range: 1~1024. 3) ESITENM (Site Equipment Name): the alias of the site for modification. Character string type. 4) RACKID (Rack ID): the ID number of the rack for modification. Signless integer, value range: 1~4. 5) TMPNO (Template NO): the template number of the main node alarm for modification. Signless integer, value range: 1~16. 1.3.1.18 ANAQ 1. Command function This command is used to query all the main node alarm settings in the system.

Page 30 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ANAQ; 3. Parameter description None. 1.3.1.19 ANMC 1. Command function This command is used to create a new main node alarm template. 2. Syntax structure ANMC: TMPNO: ND1ACLS, ND1ACNT, ND2ACLS, ND2ACNT, ND3ACLS, ND3ACNT, ND4ACLS, ND4ACNT, ND5ACLS, ND5ACNT, ND6ACLS, ND6ACNT, ND7ACLS, ND7ACNT, ND8ACLS, ND8ACNT, ND9ACLS, ND9ACNT, ND10ACLS, ND10ACNT, ND11ACLS, ND11ACNT, ND12ACLS, ND12ACNT; 3. Parameter description 1) TMPNO (Template No): the number of the main node alarm template to be created. Signless integer, value range: 1~16. 2) NDiACLS (Node i's Alarm Class): the alarm class of node i (i is from 1 to 12). Signless integer, value range: 1~4, the default value is NULL. 3) NDiACNT (Node i's Alarm Content): the alarm content if node i (i is from 1 to 12).Character string type, the default value is NULL. 1.3.1.20 ANMD 1. Command function This command is used to delete a main node alarm template.
Page 31 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ANMD: TEMPNOS; 3. Parameter description TEMPNOS (Template No): the template number of the main node. Signless integer, value range: 1~16. 1.3.1.21 ANMM 1. Command function This command is used to modify a main node alarm template. 2. Syntax structure ANMM: TMPNO: ND1ACLS, ND1ACNT, ND2ACLS, ND2ACNT, ND3ACLS, ND3ACNT, ND4ACLS, ND4ACNT, ND5ACLS, ND5ACNT, ND6ACLS, ND6ACNT, ND7ACLS, ND7ACNT, ND8ACLS, ND8ACNT, ND9ACLS, ND9ACNT, ND10ACLS, ND10ACNT, ND11ACLS, ND11ACNT, ND12ACLS, ND12ACNT; 3. Parameter description 1) TMPNO (Template NO): the number of the main node alarm template to be modified. Signless integer, value range: 1~16. 2) NDiACLS (Node i's Alarm Class): the alarm class of node i (i is from 1 to 12). Signless integer, value range: 0~4, the default value is NULL. Among them, 0 represents deleting the main node alarm, NULL represents no modification to the main node alarm. 3) NDiACNT (Node i's Alarm Content): the alarm content if node i (i is from 1 to 12).Character string type, the default value is NULL.

Page 32 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.22

ANRQ 1. Command function This command is used to query the notification for a specified object and notification code.. 2. Syntax structure ANRQ: NotiObj, NotiCode, BgnDay, BgnTime, EndDay, EndTime; 3. Parameter description 1) NotiObj: for specifying the notification object that reports notification when any notification occurs. Composite signless integer. 2) NotiCode: for specifying notification code. Composite signless integer, value range: 0~65535. 3) BgnDay: starting date for querying. Date type. 4) BgnTime: starting time for querying. Time type. 5) EndDay: ending date for querying. Date type. 6) EndTime: ending time for querying. Time type.

1.3.1.23

ASAD 1. Command function This command is used to update the knowledge database for a specified alarm code. 2. Syntax structure ASAD: AlmCode, UserDes;

Page 33 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) AlmCode: the alarm code updated by the user. Signless integer, value range: 0~65535. 2) UserDes: the solution of the user to this alarm code. Character string type. 1.3.1.24 ASBM 1. Command function This command is used to set the clock reference for a specified SYCK board. 2. Syntax structure ASBM: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): CLKBASE; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the board for setting the clock reference. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for setting the clock reference. Character string type. 3) RACKNO (Rack No): the rack number of the board for setting the clock reference. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the board for setting the clock reference. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the board for setting the clock reference. Signless integer, value range: 1~27.

Page 34 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) CLKBASE (Clock Base): the clock reference of SYCK. Signless integer, value range: 0~3. 1.3.1.25 ASDL 1. Command function This command is used to perform off-line operation for a specified MP board. 2. Syntax structure ASDL: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the MP board for off-line operation. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for off-line operation. Character string type. 3) RACKNO (Rack No): the rack number of the MP board for off-line operation Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the MP board for off-line operation. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the MP board for off-line operation. Signless integer, value range: 1~27. 1.3.1.26 ASDN 1. Command function This command is used to disable changeover for a specified SYCK board. 2. Syntax structure
Page 35 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ASDN: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the SYCK board for disabling changeover. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the SYCK board for disabling changeover. Character string type. 3) RACKNO (Rack No): the rack number of the SYCK board for disabling changeover. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the SYCK board for disabling changeover. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the SYCK board for disabling changeover. Signless integer, value range: 1~27. 1.3.1.27 ASDR 1. Command function This command is used to reset a specified board in MP and PP. 2. Syntax structure ASDR: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the board for resetting . Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for resetting . Character string type.

Page 36 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) RACKNO (Rack No): the rack number of the board for resetting. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the board for resetting. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the board for resetting. Signless integer, value range: 1~27. 1.3.1.28 ASDT 1. Command function This command is used to perform de-offline operation for a specified MP board.. 2. Syntax structure ASDT: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the MP board for de-offline operation. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the MP board for de-offline operation. Character string type. 3) RACKNO (Rack No): the rack number of the MP board for de-offline operation. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the MP board for de-offline operation. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the MP board for de-offline operation. Signless integer, value range: 1~27.

Page 37 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.29

ASDW 1. Command function This command is used to perform active/standby changeover for a specified board among MP, PP, SYCK and DSNI. 2. Syntax structure ASDW: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the board for active/standby changeover. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the board for active/standby changeover. Character string type. 3) RACKNO (Rack No): the rack number of the board for active/standby changeover. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the board for active/standby changeover. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the board for active/standby changeover. Signless integer, value range: 1~27.

1.3.1.30

ASDY 1. Command function This command is used to allow changeover for a specified SYCK board. 2. Syntax structure ASDY: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO;

Page 38 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the SYCK board for allowing changeover. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the SYCK board for allowing changeover. Character string type. 3) RACKNO (Rack No): the rack number of the SYCK board for allowing changeover. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the SYCK board for allowing changeover. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the SYCK board for allowing changeover. Signless integer, value range: 1~27. 1.3.1.31 ASRD 1. Command function This command is used to update the knowledge database of a specified alarm reason code. 2. Syntax structure ASRD: RsnCode, UserDes; 3. Parameter description 1) RsnCode: the alarm reason code updated by the user. Signless integer, value range: 0~65535. 2) UserDes: the description of the alarm reason code given by the user. Character string type.

Page 39 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.32

ASSP 1. Command function This command is used to modify the dump parameter. 2. Syntax structure ASSP: SaveDay, SavePrd, SaveTime, Flag; 3. Parameter description 1) SaveDay: for specifying how long the data will be saved in the local database.. Signless integer, value range: 30~180, the default is 90 days. 2) SavePrd: the automatic dumping period of the database (day). Signless integer, value range: 1~60, the default is 20 days. 3) SaveTime: the time for dumping each time. Time type, the default value is 1-00. 4) Flag: automatic dumping flag. Signless integer, value range: 1~2, the default is 1.

1.3.1.33

ASTA 1. Command function This command is used to query alarm statistic information. 2. Syntax structure ASTA: STATYPE, STACOUNT, ISCLEAR, ISFILTER, ALMOBJ, ALMCLS, BGNDAY, BGNTIME, ENDDAY, ENDTIME, FLAG; 3. Parameter description

Page 40 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) STATYPE: for specifying alarm statistic type. Signless integer, value range: 0~2, it must be 0 at present (frequency statistics). 2) STACOUNT: for specifying to take statistics only for the number of alarms that occur most frequently, 0 means to take statistics for all. Signless integer, value range: 0~65535. 3) ISCLEAR: for specifying whether to clear. Signless integer, value range: 0~2, in which 0: not to clear, 1: to clear, 2: to clear and not to clear. 4) ISFILTER: for specifying whether to filter. Signless integer, value range: 0~2, in which, 0: not to filter, 1: to filter, 2: to filter and not to filter. 5) ALMOBJ: for specifying the alarm object. Character string type. 6) ALMCLS: for specifying alarm class. Composite signless integer, value range: 1~4, separated with &, e.g., 1&2&3. 7) BGNDAY: starting date for querying. Date type. 8) BGNTIME: starting time for querying. Time type. 9) ENDDAY: ending date for querying. Date type. 10) 1.3.1.34 ATDR 1. Command function To perform remote resetting for a specified BTS Site or board. 2. Syntax structure ATDR: EBSSID, {ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO; 3. Parameter description ENDTIME: ending time for querying. Time type.

Page 41 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSSID (BSS Equipment ID): the BSS ID number of the BTS Site or board for remote resetting . Signless integer, value range: 1~255. 2) ESITEID (Site Equipment ID): the site ID number of the BTS Site or board for remote resetting . Signless integer, value range: 1~1024. 3) ESITENM (Site Equipment Name): the site alias of the BTS Site or board for remote resetting . Character string type. 4) RACKNO (Rack No): the rack number of the BTS board for remote resetting . Signless integer, value range: 1~15, the default value is NULL. 5) SHELFNO (Shelf No): the shelf number of the BTS board for remote resetting . Signless integer, value range: 1~6, the default value is NULL. 6) PANELNO (Panel No): the slot number of the BTS board for remote resetting . Signless integer, value range: 1~27, the default value is NULL. 1.3.1.35 ATHM 1. Command function This command is used to set the temperature and humidity alarms of a specified BSC module, including the upper and lower limits of normal temperature and humidity. 2. Syntax structure ATHM: {EBSCID, EBSCNAME}, MODULENO: TEMPLOW, tEMPUP, HUMIDLOW, HUMIDUP; 3. Parameter description 1) EBSCID (BSC Equipment ID): the ID number of the BSC for setting temperature and humidity alarms. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the alias of the BSC for setting temperature and humidity alarms. Character string type.
Page 42 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No): the module number for setting temperature and humidity alarms. Signless integer, value range: 1~64. 4) TEMPLOW (Low Temperature): lower limit of normal temperature. temperature type, value range: 0.0~45.0 . 5) TEMPUP (High Temperature): upper limit of normal temperature. temperature type, value range: 0.0~45.0 . 6) HUMIDLOW (Low Humidity): lower limit of normal humidity. Percent type, value range: 20.0% to 80.0%. 7) HUMIDUP (High Humidity): upper limit of normal humidity. Percent type, value range: 20.0% to 80.0%. 1.3.1.36 FBCC 1. Command function This command specifies an alarm filter rule for a specified BSC board MO to filter the alarms of the specified code in the specified BSC board MO. 2. Syntax structure FBCC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): ALMCODE, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) RACKNO (Rack No): the rack number of the filter object MO. Signless integer, value range: 1~15.

Page 43 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) SHELFNO (Shelf No): the shelf number of the filter object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the filter object MO. Signless integer, value range: 1~27. 6) ALMCLASS (Alarm Class): the alarm code of the filter action. Signless integer, value range: 0~65535. 7) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 8) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 9) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.37 FBLC 1. Command function This command sets up an alarm filter rule for a specified BSC board MO to filter the alarms of the specified class in the specified BSC board MO. 2. Syntax structure FBLC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): ALMCLASS, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255.

Page 44 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) RACKNO (Rack No): the rack number of the filter object MO. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the filter object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the filter object MO. Signless integer, value range: 1~27. 6) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 0~65535. 7) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 8) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 9) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.38 FBNC 1. Command function This command sets up an alarm filter rule for a specified BSC board MO to filter the alarms of the specified BSC board MO. 2. Syntax structure FBNC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): FILMODE, ACKMODE, RLSTATUS;

Page 45 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) RACKNO (Rack No): the rack number of the filter object MO. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the filter object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the filter object MO. Signless integer, value range: 1~27. 6) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 7) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 8) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.39 FCBC 1. Command function This command sets up a merging correlation rule for the alarms of a specified code in a specified BSC board MO. 2. Syntax structure

Page 46 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FCBC: {EBSCID, EBSCNAME} [, RACKNO, SHELFNO, SLOTNO]: ALMCODE [, RLMEMO], RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) RACKNO (Rack No): the rack number of the filter object MO. Signless integer, value range: 1~15. 4) SHELFNO (Shelf No): the shelf number of the filter object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): the slot number of the filter object MO. Signless integer, value range: 1~27. 6) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 0~65535. 7) RLMEMO: rule memo. Character string type, the default value is NULL. 8) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.40 FCMC 1. Command function This command sets up a merging correlation rule for the alarms of a specified code in OMCR. 2. Syntax structure FCMC: OMCRID: ALMCODE [, RLMEMO], RLSTATUS;
Page 47 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) OMCRID (OMCR ID): OMCR ID number of the merging object. Signless integer, value range: 1, the default value is 1. 2) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 32768 to 65535. 3) RLMEMO: rule memo. Character string type, the default value is NULL. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.41 FCOC 1. Command function This command sets up a merging correlation rule for the alarms of a specified code in a specified other type of MO of BSC (including BSC, module and PCM line). 2. Syntax structure FCOC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: ALMCODE, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): BSC ID number of the merging object MO. Signless integer, value range: 1~255, the default value is NULL. 2) EBSCNAME (BSC Equipment Name): BSC alias of the merging object MO. Character string type, the default value is NULL. 3) MODULENO (Module No): module number of the merging object MO. Signless integer, value range: 1~64, the default value is NULL.

Page 48 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNITNO (Multi-Unit No ): multi-unit number of the merging object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the merging object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the merging object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 0~65535. 8) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.42 FCRM 1. Command function This command is used to modify a specified alarm merging correlation rule. 2. Syntax structure FCRM: RULEID: RLMEMO, RLSTATUS; 3. Parameter description 1) RULEID (Rule ID): the ID number of the alarm merging correlation rule to be modified. Signless integer, value range: 1~65535. 2) RLMEMO: rule memo. Character string type, the default value is NULL. 3) RLSTATUS (Rule Status): new rule status. Signless integer, value range: 0, 1. The default value is NULL. 1.3.1.43 FCTC 1. Command function
Page 49 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command sets up a merging correlation rule for the alarms of a specified code in a specified MO of BTS. 2. Syntax structure FCTC: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME} {, tRXID, RCID} [, CHID]: ALMCODE [, RLMEMO], RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the merging object MO. Signless integer, value range: 1~255, the default value is NULL. 2) SITEID (Site ID): site ID number of the merging object MO. Signless integer, value range: 1~1024, the default value is NULL. 3) SITENAME (Site Name): site alias of the merging object MO. Character string type, the default value is NULL. 4) BTSID (BTS ID): BTS ID number of the merging object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the merging object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the merging object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCID (Radio Carrier ID): CU ID number of the merging object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHID (Channel ID): channel ID number of the merging object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 0~65535.

Page 50 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

10) NULL.

RLMEMO: rule memo. Character string type, the default value is

11) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.44 FFCC 1. Command function This command sets up a alarm filter rule to filter the alarms of a specified code for a specified MOC. 2. Syntax structure FFCC: MOCNAME: ALMCODE, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) MOCNAME (MOC Name): MOC name of the filter object. Character string type. 2) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 0~65535. 3) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 4) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 5) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 51 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.45

FFLC 1. Command function This command sets up a alarm filter rule to filter the alarms of a specified class for a specified MOC. 2. Syntax structure FFLC: MOCNAME: ALMCLASS, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) MOCNAME (MOC Name): MOC name of the filter object. Character string type. 2) ALMCLASS (Alarm Class): alarm class of the filter action. Signless integer, value range: 1~4. 3) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 4) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 5) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

1.3.1.46

FFNC 1. Command function This command sets up a alarm filter rule to filter a specified MOC. 2. Syntax structure

Page 52 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FFNC: MOCNAME: FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) MOCNAME (MOC Name): MOC name of the filter object. Character string type. 2) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 3) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.47 FFRM 1. Command function This command is used to modify a specified alarm filter rule. 2. Syntax structure FFRM: RULEID: NFILMODE, NACKMODE, RLSTATUS; 3. Parameter description 1) RULEID (Rule ID): the ID number of the alarm filter rule to be modified. Signless integer, value range: 1~65535. 2) NFILMODE (New Filter Mode): new filter mode. Signless integer, value range: 0, 1. The default value is NULL. Among them, : 0: displaying filter; 1: database filter.

Page 53 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) NACKMODE (Acknowledge Mode): new acknowledgement mode. Signless integer, value range: 0~2, the default value is NULL. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is NULL. Among them, : 0: activated state; 1: inactivated state. 1.3.1.48 FMCC 1. Command function This command sets up a alarm filter rule to filter the alarms of a specified code for a specified OMCR.. 2. Syntax structure7 FMCC: OMCRID: ALMCODE, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) OMCRID (OMCR ID): the OMCR ID number of the filter object. Signless integer, value range: 1, the default value is 1. 2) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 32768 to 65535. 3) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 4) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 5) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 54 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.49

FMLC 1. Command function This command sets up a alarm filter rule to filter the alarms of a specified class for a specified OMCR. 2. Syntax structure FMLC: OMCRID: ALMCLASS, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) OMCRID (OMCR ID): the OMCR ID number of the filter object. Signless integer, value range: 1, the default value is 1. 2) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 32768 to 65535. 3) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 4) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 5) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

1.3.1.50

FMNC 1. Command function This command sets up a alarm filter rule to filter a specified OMCR. 2. Syntax structure

Page 55 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FMNC: OMCRID: FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) OMCRID (OMCR ID): the OMCR ID number of the filter object. Signless integer, value range: 1, the default value is 1. 2) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 3) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.51 FNBC 1. Command function This command sets up a counting correlation rule for the alarms of a specified code in a specified board MO of BSC. 2. Syntax structure FNBC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): ALMCODE, CNTNUM, CNTTMLEN: NALMCODE, NALMCLS, NALMTEXT, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): BSC ID number of the counting object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC alias of the counting object MO. Character string type.
Page 56 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) RACKNO (Rack No): rack number of the counting object MO. Signless integer, value range: 1~15. 4) SHELFNO: shelf number of the counting object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): slot number of the counting object MO. Signless integer, value range: 1~27. 6) ALMCODE (Alarm Code): alarm code of the counting action. Signless integer, value range: 0~65535. 7) CNTNUM (Count Number): the original alarm count number for generating new alarms. Signless integer, value range: 1~65535. 8) CNTTMLEN (Count Time Length): time length for alarm count to happen (unit: second). Signless integer, value range: 1~65535. 9) NALMCODE (New Alarm Code): the code of the newly generated alarm. Signless integer, value range: 65280~65344. 10) NALMCLS (New Alarm Class): the class of the newly generated alarm. Signless integer, value range: 1~4. 11) NALMTXT (New Alarm Text): the content of the newly generated alarm. Character string type. 12) NULL. RLMEMO: rule memo. Character string type, the default value is

13) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.52 FNMC 1. Command function

Page 57 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command sets up a counting correlation rule for the alarms of a specified code in OMCR. 2. Syntax structure FNMC: OMCRID: ALMCODE, CNTNUM, CNTTMLEN: ALMCODE, NALMCLS, NALMTXT, RLMEMO, RLSTATUS; 3. Parameter description 1) OMCRID (OMCR ID): OMCR ID number of the counting object. Signless integer, value range: 1, the default value is 1. 2) ALMCODE (Alarm Code): alarm code of the counting action. Signless integer, value range: 0~65535. 3) CNTNUM (Count Number): the original alarm count number for generating new alarms. Signless integer, value range: 1~65535. 4) CNTTMLEN (Count Time Length): time length for alarm count to happen (unit: second). Signless integer, value range: 1~65535. 5) NALMCODE (New Alarm Code): the code of the newly generated alarm. Signless integer, value range: 65280~65344. 6) NALMCLS (New Alarm Class): the class of the newly generated alarm. Signless integer, value range: 1~4. 7) NALMTXT (New Alarm Text): the content of the newly generated alarm. Character string type. 8) RLMEMO: rule memo. Character string type, the default value is NULL. 9) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 58 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.53

FNOC 1. Command function This command sets up a counting correlation rule for the alarms of a specified code in a specified other type of BSC MO (including BSC, module and PCM line). 2. Syntax structure FNOC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: ALMCODE, CNTNUM, CNTTMLEN: NALMCODE, NALMCLS, NALMTEXT, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): BSC ID number of the merging object MO. Signless integer, value range: 1~255, the default value is NULL. 2) EBSCNAME (BSC Equipment Name): BSC alias of the merging object MO. Character string type, the default value is NULL. 3) MODULENO (Module No): module number of the merging object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNO (Multi-Unit No): multi-unit number of the merging object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the merging object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the merging object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 0~65535.

Page 59 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) CNTNUM (Count Number): the original alarm count number for generating new alarms. Signless integer, value range: 1~65535. 9) CNTTMLEN (Count Time Length): time length for alarm count to happen (unit: second). Signless integer, value range: 1~65535. 10) NALMCODE (New Alarm Code): the code of the newly generated alarm. Signless integer, value range: 65280~65344. 11) NALMCLS (New Alarm Class): the class of the newly generated alarm. Signless integer, value range: 1~4. 12) NALMTXT (New Alarm Text): the content of the newly generated alarm. Character string type. 13) NULL. 14) 1.3.1.54 FNRM 1. Command function This command is used to modify a specified alarm counting correlation rule. 2. Syntax structure FNRM: RULEID: CNTNUM, CNTTMLEN, NALMCODE, NALMCLS, NALMTEXT, RLMEMO, RLSTATUS; 3. Parameter description 1) RULEID (Rule ID): ID number of the counting correlation rule. Signless integer, value range: 0~65535. RLMEMO: rule memo. Character string type, the default value is

RLSTATUS: rule status.

Page 60 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) CNTNUM (Count Number): the original alarm count number for generating new alarms. Signless integer, value range: 1~65535. 3) CNTTMLEN (Count Time Length): time length for alarm count to happen (unit: second). Signless integer, value range: 1~65535. 4) NALMCODE (New Alarm Code): the code of the newly generated alarm. Signless integer, value range: 65280~65344. 5) NALMCLS (New Alarm Class): the class of the newly generated alarm. Signless integer, value range: 1~4. 6) NALMTXT (New Alarm Text): the content of the newly generated alarm. Character string type. 7) RLMEMO: rule memo. Character string type, the default value is NULL. 8) RLSTATUS: rule status. 1.3.1.55 FNTC 1. Command function This command sets up a counting correlation rule for the alarms of a specified code in a specified MO of BTS. 2. Syntax structure FNTC: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME} {, tRXID, RCID} [, CHID]: ALMCODE, CNTNUM, CNTTMLEN: NALMCODE, NALMCLS, NALMTEXT, RLMEMO, RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the counting object MO. Signless integer, value range: 1 to 255.

Page 61 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) SITEID (Site ID): Site ID number of the counting object MO. Signless integer, value range: 1 to 1024. 3) SITENAME (Site Name): Site alias of the counting object MO. Character string type. 4) BTSID (BTS ID): BTS ID number of the counting object MO. Signless integer, value range: 1 to 3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the counting object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the counting object MO. Signless integer, value range: 1 to 32, the default value is NULL. 7) RCID (Radio Carrier ID): CU ID number of the counting object MO. Signless integer, value range: 1 to 32, the default value is NULL. 8) CHID (Channel ID): Channel ID number of the counting object MO. Signless integer, value range: 0 to 7, the default value is NULL. 9) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 0~65535. 10) CNTNUM (Count Number): the original alarm count number for generating new alarms. Signless integer, value range: 1~65535. 11) CNTTMLEN (Count Time Length): time length for alarm count to happen (unit: second). Signless integer, value range: 1~65535. 12) NALMCODE (New Alarm Code): the code of the newly generated alarm. Signless integer, value range: 65280~65344. 13) NALMCLS (New Alarm Class): the class of the newly generated alarm. Signless integer, value range: 1~4. 14) NALMTEXT (New Alarm Text): the content of the newly generated alarm. Character string type.
Page 62 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

15) NULL.

RLMEMO: rule memo. Character string type, the default value is

16) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.56 FOCC 1. Command function This command sets up an alarm filter rule for a specified other type of BSC MO (including BSC, module and PCM line) to filter the alarm of a specified code in a specified other type of BSC MO. 2. Syntax structure FOCC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: ALMCODE, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): BSC ID number of the merging object MO. Signless integer, value range: 1~255, the default value is NULL. 2) EBSCNAME (BSC Equipment Name): BSC alias of the merging object MO. Character string type, the default value is NULL. 3) MODULENO (Module No): module number of the merging object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNO (Multi-Unit No): multi-unit number of the merging object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the merging object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the merging object MO. Signless integer, value range: 1~4, the default value is NULL.
Page 63 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) ALMCODE (Alarm Code): alarm code of the merging action. Signless integer, value range: 0~65535. 8) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 9) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 10) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.57 FOLC 1. Command function This command sets up an alarm filter rule for a specified other type of BSC MO (including BSC, module and PCM line) to filter the alarm of a specified class in a specified other type of BSC MO. 2. Syntax structure FOLC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: ALMCLASS, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) MODULENO (Module No): module number of the filter object MO. Signless integer, value range: 1~64, the default value is NULL.

Page 64 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNITNO (Multi-Unit No): multi-unit number of the filter object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the filter object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the filter object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCLASS (Alarm Class): alarm class of the filter action. Signless integer, value range: 1~4. 8) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 9) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 10) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.58 FONC 1. Command function This command sets up an alarm filter rule for a specified other type of BSC MO (including BSC, module and PCM line) to filter the alarm of a specified other type of BSC MO. 2. Syntax structure FONC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: FILMODE, ACKMODE, RLSTATUS; 3. Parameter description

Page 65 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) MODULENO (Module No): module number of the filter object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNO (Multi-Unit No): multi-unit number of the filter object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the filter object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the filter object MO. Signless integer, value range: 1~4, the default value is NULL. 7) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 8) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 9) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.59 FRBC 1. Command function This command sets up a reclassification rule for the alarm of a BSC board to redefine the class of a specified alarm code for a board MO of BSC.. 2. Syntax structure

Page 66 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FRBC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): ALMCODE, NALMCLS, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): BSC ID number of the reclassification object MO. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC alias of the reclassification object MO. Character string type. 3) RACKNO (Rack No): rack number of the reclassification object MO. Signless integer, value range: 1~15. 4) SHELFNO: shelf number of the reclassification object MO. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): slot number of the reclassification object MO. Signless integer, value range: 1~27. 6) ALMCODE (Alarm Code): code of the alarm for redefining the alarm class. Signless integer, value range: 32768 to 65535. 7) NALMCLS (New Alarm Class): the redefined new alarm class. Signless integer, value range: 1~4. 8) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.60 FRCC 1. Command function This command sets up an alarm reclassification rule to redefine the class of a specified alarm for a specified MOC or redefine the class of a specified alarm code. 2. Syntax structure
Page 67 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FRCC: MOCNAME: ALMCODE, NALMCLS, RLSTATUS; 3. Parameter description 1) MOCNAME (MOC Name): MOC name of the reclassification object. Character string type, the default value is NULL. 2) ALMCODE (Alarm Code): code of the alarm for redefining the alarm class. Signless integer, value range: 32768 to 65535. 3) NALMCLS (New Alarm Class): the redefined new alarm class. Signless integer, value range: 1~4. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.61 FRCD 1. Command function This command deletes a specified alarm reclassification rule. 2. Syntax structure FRCD: RULEIDS; 3. Parameter description RULEIDS (Rule ID): the ID number of the alarm reclassification rule to be deleted. Signless integer, value range: 1~65535. 1.3.1.62 FRCQ 1. Command function This command is used to query all alarm reclassification rules. 2. Synta x structure
Page 68 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FRCQ; 3. Parameter description None. 1.3.1.63 FRFD 1. Command function This command is used to delete a specified alarm filter rule . 2. Syntax structure FRFD: RULEIDS; 3. Parameter description RULEIDS (Rule IDs): the ID number of the alarm filter rule to be deleted. Signless integer, value range: 1~65535. 1.3.1.64 FRFQ 1. Command function This command is used to query all alarm filter rules. 2. Syntax structure FRFQ; 3. Parameter description None. 1.3.1.65 FRMC 1. Command function
Page 69 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command sets up an alarm reclassification rule to redefine the class of a specified alarm for a specified OMCR MO (or for an alarm code). 2. Syntax structure FRMC: OMCRID: ALMCODE, NALMCLS, RLSTATUS; 3. Parameter description 1) OMCRID (OMCR ID): OMCR ID number of the reclassification object. Signless integer, value range: 1, the default value is 1. 2) ALMCODE (Alarm Code): the code of the alarm for redefining alarm class. Signless integer, value range: 32768 to 65535. 3) NALMCLS (New Alarm Class): the redefined new alarm class. Signless integer, value range: 1~4. 4) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.66 FROC 1. Command function This command sets up an alarm reclassification rule for BSC, to redefine the class of a specified alarm for a specified other type of BSC MO (including BSC, module and PCM line). 2. Syntax structure FROC: {EBSCID, EBSCNAME}, MODULENO [, MUNITNO, UNITNO, PCMNO]: ALMCODE, NALMCLS, RLSTATUS; 3. Parameter description 1) EBSCID (BSC Equipment ID): the BSC ID number of the filter object MO. Signless integer, value range: 1~255.
Page 70 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): the BSC alias of the filter object MO. Character string type. 3) MODULENO (Module No): module number of the filter object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNO (Multi-Unit No): multi-unit number of the filter object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNO (Unit No): unit number of the filter object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNO (PCM No): PCM number of the filter object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODE (Alarm Code): the code of the alarm for redefining alarm class. Signless integer, value range: 32768 to 65535. 8) NALMCLS (New Alarm Class): the redefined new alarm class. Signless integer, value range: 1~4. 9) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.67 FRRD 1. Command function This command is used to delete a specified alarm correlation rule. 2. Syntax structure FRRD: RULEIDS; 3. Parameter description RULEIDS (Rule IDs): the ID number of the alarm correlation rule to be deleted. Signless integer, value range: 1~65535.
Page 71 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.68

FRRM 1. Command function This command is used to modify a specified alarm reclassification rule. 2. Syntax structure FRRM: RULEID: NEWCLASS, RLSTATUS; 3. Parameter description 1) RULEID (Rule ID): the ID number of the alarm reclassification rule to be modified. Signless integer, value range: 1~65535. 2) NEWCLASS (New Class): the redefined new alarm class. Signless integer, value range: 1~4, the default value is NULL. 3) RLSTATUS (Rule Status): new rule status. Signless integer, value range: 0, 1. The default value is NULL. Among them, : 0: activated state; 1: inactivated state.

1.3.1.69

FRRQ 1. Command function This command is used to query all alarm correlation rules. 2. Synta x structure FRRQ; 3. Parameter description None.

Page 72 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.70

FRTC 1. Command function This command sets up an alarm reclassification rule for BTS, to redefine the class of a specified alarm for a specified BTS MO.. 2. Syntax structure FRTC: BSSID{, SITEID, SITENAME}{, BTSID, BTSNAME} {, tRXID, RCID} [, CHID]: ALMCODE, NALMCLS, RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the reclassification object MO. Signless integer, value range: 1~255. 2) SITEID (Site ID): Site ID number of the reclassification object MO. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): Site alias of the reclassification object MO. Character string type. 4) BTSID (BTS ID): BTS ID number of the reclassification object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the reclassification object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the reclassification object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCID (Radio Carrier ID): CU ID number of the reclassification object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHID (Channel ID): Channel ID number of the reclassification object MO. Signless integer, value range: 0~7, the default value is NULL.

Page 73 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) ALMCODE (Alarm Code): the code of the alarm for redefining alarm class. Signless integer, value range: 32768 to 65535. 10) NALMCLS (New Alarm Class): the redefined new alarm class. Signless integer, value range: 1~4. 11) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.71 FSAC 1. Command function This command sets up an correlation rule of alarm suppression, with BSC board MO as the object for main alarm A and BTS logic MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSAC: {EBSCIDA, EBSCNMA}, RACKNOA, SHELFNOA, SLOTNOA: ALMCODEA: BSSIDB {, SITEIDB, SITENMB}{, BTSIDB, BTSNAMEB}{, tRXIDB, RCIDB}[, CHIDB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) RACKNOA (Rack No of Alarm A): rack number of the main alarm object MO. Signless integer, value range: 1~15. 4) SHELFNOA (Shelf No of Alarm A): shelf number of the main alarm object MO. Signless integer, value range: 1~6.
Page 74 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) SLOTNOA (Slot No of Alarm A): slot number of the main alarm object MO. Signless integer, value range: 1~27. 6) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 7) BSSIDB (BSS ID of Alarm B): BSS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 8) SITEIDB (Site ID of Alarm B): site ID number of the auxiliary alarm object MO. Signless integer, value range: 1~1024. 9) SITENMB (Site Name of Alarm B): site alias of the auxiliary alarm object MO. Character string type. 10) BTSIDB ( BTS ID of Alarm B): BTS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 11) BTSNAMEB ( BTS Name of Alarm B): BTS alias of the auxiliary alarm object MO. Character string type, the default value is NULL. 12) TRXIDB (Transceiver ID of Alarm B): FU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 13) RCIDB (Radio Carrier ID of Alarm B): CU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 14) CHIDB (Channel ID of Alarm B): channel ID number of the auxiliary alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 15) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535.

Page 75 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

16) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 17) NULL. RLMEMO: rule memo. Character string type, the default value is

18) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.72 FSBC 1. Command function This command sets up an correlation rule of alarm suppression, with BSC board MO as the object for both main alarm A and auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSBC: {EBSCIDA, EBSCNMA}, RACKNOA, SHELFNOA, SLOTNOA: ALMCODEA: {EBSCIDB, EBSCNMB}, RACKNOB, SHELFNOB, SLOTNOB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) RACKNOA (Rack No of Alarm A): rack number of the main alarm object MO. Signless integer, value range: 1~15. 4) SHELFNOA (Shelf No of Alarm A): shelf number of the main alarm object MO. Signless integer, value range: 1~6.

Page 76 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) SLOTNOA (Slot No of Alarm A): slot number of the main alarm object MO. Signless integer, value range: 1~27. 6) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 7) EBSCIDB (BSC Equipment ID of Alarm A): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 8) EBSCNMB (BSC Name of Alarm A): BSC alias of the auxiliary alarm object MO. Character string type. 9) RACKNOB (Rack No of Alarm A): rack number of the auxiliary alarm object MO. Signless integer, value range: 1~15. 10) SHELFNOB (Shelf No of Alarm A): shelf number of the auxiliary alarm object MO. Signless integer, value range: 1~6. 11) SLOTNOB ( Slot No of Alarm A): slot number of the auxiliary alarm object MO. Signless integer, value range: 1~27. 12) ALMCODEB (Alarm Code of Alarm A): code of the auxiliary alarm. Signless integer, value range: 0~65535. 13) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 14) NULL. RLMEMO: rule memo. Character string type, the default value is

15) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.73 FSCC 1. Command function

Page 77 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command sets up an correlation rule of alarm suppression, with BSC logic MO as the object for main alarm A and BTS logic MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSCC: {EBSCIDA, EBSCNMA}, MODLNOA [, MUNITNOA, UNITNOA, PCMNOA]: ALMCODEA: BSSIDB {, SITEIDB, SITENMB}{, BTSIDB, BTSNAMEB} {, tRXIDB, RCIDB} [, CHIDB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Equipment Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) MODLNOA (Module No of Alarm A): module number of the main alarm object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNOA (Multi-Unit No of Alarm A): multi-unit number of the main alarm object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNOA (Unit No of Alarm A): unit number of the main alarm object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNOA (PCM No of Alarm A): PCM number of the main alarm object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 8) BSSIDB (BSS ID of Alarm B): BSS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255.
Page 78 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) SITEIDB (Site D I of Alarm B): site ID number of the auxiliary alarm object MO. Signless integer, value range: 1~1024. 10) SITENMB (Site Name of Alarm B): site alias of the auxiliary alarm object MO. Character string type, the default value is NULL. 11) BTSIDB ( BTS ID of Alarm B): BTS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 12) BTSNAMEB ( BTS Name of Alarm B): BTS alias of the auxiliary alarm object MO. Character string type, the default value is NULL. 13) TRXIDB (Transceiver ID of Alarm B): FU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 14) RCIDB (Radio Carrier ID of Alarm B): CU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 15) CHIDB (Channel ID of Alarm B): channel ID number of the auxiliary alarm object MO. Signless integer, value range: 0~7. 16) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 17) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 18) RLMEMO: rule memo. Character string type, the default value is NULL. 19) RLSTATUS: rule status . Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 79 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.74

FSDC 1. Command function This command sets up an correlation rule of alarm suppression, with BSCs board MO as the object for main alarm A and BSCs other MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSDC: {EBSCIDA, EBSCNMA}, RACKNOA, SHELFNOA, SLOTNOA: ALMCODEA: {EBSCIDB, EBSCNMB}, MODLNOB [, MUNITNOB, UNITNOB, PCMNOB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) RACKNOA (Rack No of Alarm A): rack number of the main alarm object MO. Signless integer, value range: 1~15. 4) SHELFNOA (Shelf No of Alarm A): shelf number of the main alarm object MO. Signless integer, value range: 1~6. 5) SLOTNOA (Slot No of Alarm A): slot number of the main alarm object MO. Signless integer, value range: 1~27. 6) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 7) EBSCIDB (BSC Equipment ID of Alarm A): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255.

Page 80 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) EBSCNMB (BSC Name of Alarm A): BSC alias of the auxiliary alarm object MO. Character string type. 9) MODLNOB (Module No of Alarm B): module number of the auxiliary alarm object MO. Value range: 1 to 64, the default value is NULL. 10) MUNITNOB (Multi-Unit No of Alarm A): multi-unit number of the auxiliary alarm object MO. Value range: 1 to 127, the default value is NULL. 11) UNITNOB (Unit No of Alarm B): unit number of the auxiliary alarm object MO. Value range: 1 to 16, the default value is NULL. 12) PCMNOB (PCM No of Alarm B): PCM number of the auxiliary alarm object MO. Value range: 1 to 4, the default value is NULL. 13) ALMCODEB (Alarm Code of Alarm A): code of the auxiliary alarm. Signless integer, value range: 0~65535. 14) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 15) NULL. RLMEMO: rule memo. Character string type, the default value is

16) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.75 FSEC 1. Command function This command sets up an correlation rule of alarm suppression, with BTS MO as the object for main alarm A and BSC board MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure
Page 81 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FSEC: BSSIDA {, SITEIDA, SITENMA}{, BTSIDA, BTSNAMEA} {, tRXIDA, RCIDA}, [CHIDA]: ALMCODEA: {EBSCIDB, EBSCNMB}, RACKNOB, SHELFNOB, SLOTNOB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) BSSIDA (BSS ID of Alarm A): BSS ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) SITEIDA (Site ID of Alarm A): site ID number of the main alarm object MO. Signless integer, value range: 1~1024. 3) SITENMA (Site Name of Alarm A): site alias of the main alarm object MO. Character string type. 4) BTSIDA (BTS ID of Alarm A): BTS ID number of the main alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAMEA (BTS Name of Alarm A): BTS alias of the main alarm object MO. Character string type, the default value is NULL. 6) TRXIDA (Transceiver ID of Alarm A): FU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCIDA (Radio Carrier ID of Alarm A): CU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHIDA (Channel ID of Alarm A): channel ID number of the main alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 10) EEBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 11) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type.
Page 82 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

12) RACKNOB (Rack No of Alarm B): rack number of the auxiliary alarm object MO. Signless integer, value range: 1~15. 13) SHELFNOB (Shelf No of Alarm B): shelf number of the auxiliary alarm object MO. Signless integer, value range: 1~6. 14) SLOTNOB (Slot No of Alarm B): slot number of the auxiliary alarm object MO. Signless integer, value range: 1~27. 15) ALMCODEB (Alarm Code of alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 16) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 17) NULL. RLMEMO: rule memo. Character string type, the default value is

18) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.76 FSFC 1. Command function This command sets up an correlation rule of alarm suppression, with BTS MO as the object for main alarm A and BSC logic MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSFC: BSSIDA {, SITEIDA, SITENMA}{, BTSIDA, BTSNAMEA} {, tRXIDA, RCIDA} [, CHIDA]: ALMCODEA: {EBSCIDB, EBSCNMB}, MODLNOB [, MUNITNOB, UNITNOB, PCMNOB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description
Page 83 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSIDA (BSS ID of Alarm A): BSS ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) SITEIDA (Site ID of Alarm A): site ID number of the main alarm object MO. Signless integer, value range: 1~1024. 3) SITENMA (Site Name of Alarm A): site alias of the main alarm object MO. Character string type. 4) BTSIDA (BTS ID of Alarm A): BTS ID number of the main alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAMEA (BTS Name of Alarm A): BTS alias of the main alarm object MO. Character string type, the default value is NULL. 6) TRXIDA (Transceiver ID of Alarm A): FU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCIDA (Radio Carrier ID of Alarm A): CU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHIDA (Channel ID of Alarm A): channel ID number of the main alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 10) EBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 11) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type. 12) MODLNOB (Module No of Alarm B): module number of the auxiliary alarm object MO. Value range: 1 to 64, the default value is NULL. 13) MUNITNOB (Multi-Unit No of Alarm A): multi-unit number of the auxiliary alarm object MO. Value range: 1 to 127, the default value is NULL.
Page 84 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

14) UNITNOB (Unit No of Alarm B): unit number of the auxiliary alarm object MO. Value range: 1 to 16, the default value is NULL. 15) PCMNOB (PCM No of Alarm B): PCM number of the auxiliary alarm object MO. Value range: 1 to 4, the default value is NULL. 16) ALMCODEB (Alarm Code of alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 17) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 18) NULL. RLMEMO: rule memo. Character string type, the default value is

19) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.77 FSGC 1. Command function This command sets up an correlation rule of alarm suppression, with BSC logic MO as the object for main alarm A and OMCR as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSGC: {EBSCIDA, EBSCNMA}, MODLNOA [, MUNITNOA, UNITNOA, PCMNOA]: ALMCODEA: OMCRIDB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255.
Page 85 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNMA (BSC Equipment Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) MODLNOA (Module No of Alarm A): module number of the main alarm object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNOA (Multi-Unit No of Alarm A): multi-unit number of the main alarm object MO. Signless integer, value range: 1~127, the default va lue is NULL. 5) UNITNOA (Unit No of Alarm A): unit number of the main alarm object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNOA (PCM No of Alarm A): PCM number of the main alarm object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 8) OMCRIDB (OMCR ID of Alarm B): OMCR ID number of the auxiliary alarm object MO. Signless integer, value range: 1, the default value is 1. 10) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 32768 to 65535. 11) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 12) NULL. RLMEMO: rule memo. Character string type, the default value is

13) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.78 FSHC 1. Command function
Page 86 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

This command sets up an correlation rule of alarm suppression, with BTS MO as the object for main alarm A and OMCR as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSHC: BSSIDA {, SITEIDA, SITENMA}{, BTSIDA, BTSNAMEA} {, tRXIDA, RCIDA}, [CHIDA]: ALMCODEA: OMCRIDB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) BSSIDA (BSS ID of Alarm A): BSS ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) SITEIDA (Site ID of Alarm A): site ID number of the main alarm object MO. Signless integer, value range: 1~1024. 3) SITENMA (Site Name of Alarm A): site alias of the main alarm object MO. Character string type. 4) BTSIDA (BTS ID of Alarm A): BTS ID number of the main alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAMEA (BTS Name of Alarm A): BTS alias of the main alarm object MO. Character string type, the default value is NULL. 6) TRXIDA (Transceiver ID of Alarm A): FU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCIDA (Radio Carrier ID of Alarm A): CU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHIDA (Channel ID of Alarm A): channel ID number of the main alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535.
Page 87 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

10) OMCRIDB (OMCR ID of Alarm B): OMCR ID number of the auxiliary alarm object MO. Signless integer, value range: 1, the default value is 1. 11) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 32768 to 65535. 12) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 13) NULL. RLMEMO: rule memo. Character string type, the default value is

14) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.79 FSIC 1. Command function This command sets up an correlation rule of alarm suppression, with OMCR as the object for main alarm A and BSC board MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSIC: OMCRIDA: ALMCODEA: {EBSCIDB, EBSCNMB}, RACKNOB, SHELFNOB, SLOTNOB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) OMCRIDA (OMCR ID of Alarm A): OMCR ID number of the main alarm object MO. Signless integer, value range: 1, the default va lue is 1. 2) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 32768 to 65535.
Page 88 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) EBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 4) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type. 5) RACKNOB (Rack No of Alarm B): rack number of the auxiliary alarm object MO. Signless integer, value range: 1~15. 6) SHELFNOB (Shelf No of Alarm B): shelf number of the auxiliary alarm object MO. Signless integer, value range: 1~6. 7) SLOTNOB (Slot No of Alarm B): slot number of the auxiliary alarm object MO. Signless integer, value range: 1~27. 8) ALMCODEB (Alarm Code of alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 9) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 10) NULL. RLMEMO: rule memo. Character string type, the default value is

11) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.80 FSJC 1. Command function This command sets up an correlation rule of alarm suppression, with OMCR as the object for main alarm A and BSC logic MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure
Page 89 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FSJC: OMCRIDA: ALMCODEA: {EBSCIDB, EBSCNMB}, MODLNOB [, MUNITNOB, UNITNOB, PCMNOB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) OMCRIDA (OMCR ID of Alarm A): OMCR ID number of the main alarm object MO. Signless integer, value range: 1, the default value is 1. 2) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 32768 to 65535. 3) EEBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 4) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type. 5) MODLNOB (Module No of Alarm B): module number of the auxiliary alarm object MO. Value range: 1 to 64, the default value is NULL. 6) MUNITNOB (Multi-Unit No of Alarm A): multi-unit number of the auxiliary alarm object MO. Value range: 1 to 127, the default value is NULL. 7) UNITNOB (Unit No of Alarm B): unit number of the auxiliary alarm object MO. Value range: 1 to 16, the default value is NULL. 8) PCMNOB (PCM No of Alarm B): PCM number of the auxiliary alarm object MO. Value range: 1 to 4, the default value is NULL. 9) ALMCODEB (Alarm Code of alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 10) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show.

Page 90 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) NULL.

RLMEMO: rule memo. Character string type, the default value is

12) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.81 FSKC 1. Command function This command sets up an correlation rule of alarm suppression, with OMCR as the object for main alarm A and BTS MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSKC: OMCRIDA: ALMCODEA: BSSIDB {, SITEIDB, SITENAMEB}{, BTSIDB, BTSNAMEB} {, tRXIDB, RCIDB} [, CHIDB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) OMCRIDA (OMCR ID of Alarm A): OMCR ID number of the main alarm object MO. Signless integer, value range: 1, the default value is 1. 2) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 32768 to 65535. 3) BSSIDB (BSS ID of Alarm B): BSS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 4) SITEIDB (Site ID of Alarm B): site ID number of the auxiliary alarm object MO. Signless integer, value range: 1~1024. 5) SITENMB (Site Name of Alarm B): site alias of the auxiliary alarm object MO. Character string type.

Page 91 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) BTSIDB ( BTS ID of Alarm B): BTS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 7) BTSNAMEB ( BTS Name of Alarm B): BTS alias of the auxiliary alarm object MO. Character string type, the default value is NULL. 8) TRXIDB (Transceiver ID of Alarm B): FU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 9) RCIDB (Radio Carrier ID of Alarm B): CU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 10) CHIDB (Channel ID of Alarm B): channel ID number of the auxiliary alarm object MO. Signless integer, value range: 0~7. 11) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 12) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 13) NULL. RLMEMO: rule memo. Character string type, the default value is

14) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.82 FSMC 1. Command function This command sets up an correlation rule of alarm suppression, with BSC board MO as the object for main alarm A and OMCR as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B.
Page 92 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure FSMC: {EBSCIDA, EBSCNMA}, RACKNOA, SHELFNOA, SLOTNOA: ALMCODEA: OMCRIDB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) RACKNOA (Rack No of Alarm A): rack number of the main alarm object MO. Signless integer, value range: 1~15. 4) SHELFNOA (Shelf No of Alarm A): shelf number of the main alarm object MO. Signless integer, value range: 1~6. 5) SLOTNOA (Slot No of Alarm A): slot number of the main alarm object MO. Signless integer, value range: 1~27. 6) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 7) OMCRIDB (OMCR ID of Alarm B): OMCR ID number of the auxiliary alarm object MO. Signless integer, value range: 1, the default value is 1. 8) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 32768 to 65535. 9) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 10) NULL. RLMEMO: rule memo. Character string type, the default value is

Page 93 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activa ted state; 1: inactivated state. 1.3.1.83 FSOC 1. Command function This command sets up an correlation rule of alarm suppression, with BSCs other MO as the object for both main alarm A and auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSOC: {EBSCIDA, EBSCNMA}, MODLNOA [, MUNITNOA, UNITNOA, PCMNOA]: ALMCODEA: {EBSCIDB, EBSCNMB}, MODLNOB [, MUNITNOB, UNITNOB, PCMNOB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Equipment Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) MODLNOA (Module No of Alarm A): module number of the main alarm object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNOA (Multi-Unit No of Alarm A): multi-unit number of the main alarm object MO. Signless integer, value range: 1~127, the default value is NULL. 5) UNITNOA (Unit No of Alarm A): unit number of the main alarm object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNOA (PCM No of Alarm A): PCM number of the main alarm object MO. Signless integer, value range: 1~4, the default value is NULL.
Page 94 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 8) EBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 9) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type. 10) MODLNOB (Module No of Alarm B): module number of the auxiliary alarm object MO. Signless integer, value range: 1~64, the default value is NULL. 11) MUNITNOB (Multi-Unit No of Alarm B): multi-unit number of the auxiliary alarm object MO. Signless integer, value range: 1~127, the default value is NULL. 12) UNITNOB (Unit No of Alarm B): unit number of the auxiliary alarm object MO. Signless integer, value range: 1~16, the default value is NULL. 13) PCMNOB (PCM No of Alarm B): PCM number of the auxiliary alarm object MO. Signless integer, value range: 1~4, the default value is NULL. 14) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 15) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 16) NULL. RLMEMO: rule memo. Character string type, the default value is

17) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 95 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.84

FSTC 1. Command function This command sets up an correlation rule of alarm suppression, with BTS MO as the object for both main alarm A and auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSTC: BSSIDA {, SITEIDA, SITENMA}{, BTSIDA, BTSNAMEA} {, tRXIDA, RCIDA} [, CHIDA]: ALMCODEA: BSSIDB {, SITEIDB, SITENMB}{, BTSIDB, BTSNAMEB} {, tRXIDB, RCIDB} [, CHIDB]: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) BSSIDA (BSS ID of Alarm A): BSS ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) SITEIDA (Site ID of Alarm A): site ID number of the main alarm object MO. Signless integer, value range: 1~1024. 3) SITENMA (Site Name of Alarm A): site alias of the main alarm object MO. Character string type. 4) BTSIDA (BTS ID of Alarm A): BTS ID number of the main alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAMEA (BTS Name of Alarm A): BTS alias of the main alarm object MO. Character string type, the default value is NULL. 6) TRXIDA (Transceiver ID of Alarm A): FU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCIDA (Radio Carrier ID of Alarm A): CU ID number of the main alarm object MO. Signless integer, value range: 1~32, the default value is NULL.

Page 96 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) CHIDA (Channel ID of Alarm A): channel ID number of the main alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 10) BSSIDB (BSS ID of Alarm B): BSS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~255. 11) SITEIDB (Site ID of Alarm B): site ID number of the auxiliary alarm object MO. Signless integer, value range: 1~1024. 12) SITENMB (Site Name of Alarm B): site alias of the auxiliary alarm object MO. Character string type. 13) BTSIDB ( BTS ID of Alarm B): BTS ID number of the auxiliary alarm object MO. Signless integer, value range: 1~3, the default value is NULL. 14) BTSNAMEB ( BTS Name of Alarm B): BTS alias of the auxiliary alarm object MO. Character string type, the default value is NULL. 15) TRXIDB (Transceiver ID of Alarm B): FU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 16) RCIDB (Radio Carrier ID of Alarm B): CU ID number of the auxiliary alarm object MO. Signless integer, value range: 1~32, the default value is NULL. 17) CHIDB (Channel ID of Alarm B): channel ID number of the auxiliary alarm object MO. Signless integer, value range: 0~7, the default value is NULL. 18) ALMCODEB (Alarm Code of Alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535.

Page 97 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

19) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 20) NULL. RLMEMO: rule memo. Character string type, the default value is

21) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.85 FSUC 1. Command function This command sets up an correlation rule of alarm suppression, with BSCs other type of MO as the object for main alarm A and BSCs board MO as the object for auxiliary alarm B, so as to establish the correlation between alarm A and alarm B. 2. Syntax structure FSUC: {EBSCIDA, EBSCNMA}, MODLNOA [, MUNITNOA, UNITNOA, PCMNOA]: ALMCODEA: {EBSCIDB, EBSCNMB}, RACKNOB, SHELFNOB, SLOTNOB: ALMCODEB: ISSHOWB, RLMEMO, RLSTATUS; 3. Parameter description 1) EBSCIDA (BSC Equipment ID of Alarm A): BSC ID number of the main alarm object MO. Signless integer, value range: 1~255. 2) EBSCNMA (BSC Equipment Name of Alarm A): BSC alias of the main alarm object MO. Character string type. 3) MODLNOA (Module No of Alarm A): module number of the main alarm object MO. Signless integer, value range: 1~64, the default value is NULL. 4) MUNITNOA (Multi-Unit No of Alarm A): multi-unit number of the main alarm object MO. Signless integer, value range: 1~127, the default value is NULL.
Page 98 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNITNOA (Unit No of Alarm A): unit number of the main alarm object MO. Signless integer, value range: 1~16, the default value is NULL. 6) PCMNOA (PCM No of Alarm A): PCM number of the main a larm object MO. Signless integer, value range: 1~4, the default value is NULL. 7) ALMCODEA (Alarm Code of Alarm A): code of the main alarm. Signless integer, value range: 0~65535. 8) EBSCIDB (BSC Equipment ID of Alarm B): BSC ID number of the auxiliary a larm object MO. Signless integer, value range: 1~255. 9) EBSCNMB (BSC Equipment Name of Alarm B): BSC alias of the auxiliary alarm object MO. Character string type. 10) RACKNOB (Rack No of Alarm B): rack number of the auxiliary alarm object MO. Signless integer, value range: 1~15. 11) SHELFNOB (Shelf No of Alarm B): shelf number of the auxiliary alarm object MO. Signless integer, value range: 1~6. 12) SLOTNOB (Slot No of Alarm B): slot number of the auxiliary alarm object MO. Signless integer, value range: 1~27. 13) ALMCODEB (Alarm Code of alarm B): code of the auxiliary alarm. Signless integer, value range: 0~65535. 14) ISSHOWB (Is Show Alarm B): whether to show the auxiliary alarm after the main alarm is restored. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: to show; 0: not to show. 15) NULL. RLMEMO: rule memo. Character string type, the default value is

16) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.

Page 99 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.1.86

FTCC 1. Command function This command sets up an alarm filter rule for a specified MO of BTS to filter the alarms of a specified code in a specified MO of BTS. 2. Syntax structure FTCC: BSSID {, SITEID, SITENAME}{, BTSID, BTS NAME} {, tRXID, RCID} [, CHID]: ALMCODE, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the filter object MO. Signless integer, value range: 1~255. 2) SITEID (Site ID): site ID number of the filter object MO. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site alias of the filter object MO. Character string type. 4) BTSID (BTS ID): BTS ID number of the filter object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the filter object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCID (Radio Carrier ID): C U ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHID (Channel ID): channel ID number of the filter object MO. Signless integer, value range: 0~7, the default value is NULL.

Page 100 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) ALMCODE (Alarm Code): the alarm code of the filter action. Signless integer, value range: 0~65535. 10) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 11) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 12) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.87 FTLC 1. Command function This command sets up an alarm filter rule for a specified MO of BTS to filter the alarms of a specified class in a specified MO of BTS. 2. Syntax structure FTLC: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME} {, tRXID, RCID} [, CHID]: ALMCLASS, FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the filter object MO. Signless integer, value range: 1~255. 2) SITE ID (Site ID): site ID number of the filter object MO. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site alias of the filter object MO. Character string type.

Page 101 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) BTSID (BTS ID): BTS ID number of the filter object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the filter object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCID (Radio Carrier ID): CU ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHID (Channel ID): channel ID number of the filter object MO. Signless integer, value range: 0~7, the default value is NULL. 9) ALMCLASS (Alarm Class): the alarm code of the filter action. Signless integer, value range: 0~65535. 10) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 11) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 12) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state. 1.3.1.88 FTNC 1. Command function This command sets up an alarm filter rule for a specified MO of BTS to filter the alarms for a specified MO of BTS. 2. Syntax structure
Page 102 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

FTNC: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME} {, tRXID, RCID} [, CHID]: FILMODE, ACKMODE, RLSTATUS; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the filter object MO. Signless integer, value range: 1~255. 2) SITEID (Site ID): site ID number of the filter object MO. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site alias of the filter object MO. Character string type. 4) BTSID (BTS ID): BTS ID number of the filter object MO. Signless integer, value range: 1~3, the default value is NULL. 5) BTSNAME (BTS Name): BTS alias of the filter object MO. Character string type, the default value is NULL. 6) TRXID (Transceiver ID): FU ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 7) RCID (Radio Carrier ID): CU ID number of the filter object MO. Signless integer, value range: 1~32, the default value is NULL. 8) CHID (Channel ID): channel ID number of the filter object MO. Signless integer, value range: 0~7, the default value is NULL. 9) FILMODE (Filter Mode): filter mode. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: displaying filter; 1: database filter. 10) ACKMODE (Acknowledge Mode): acknowledgement mode. Signless integer, value range: 0~2, the default value is 1. Among them, : 0: no acknowledgement; 1: acknowledgement upon receiving; 2: clearing acknowledgement. 11) RLSTATUS: rule status. Signless integer, value range: 0, 1. The default value is 0. Among them, : 0: activated state; 1: inactivated state.
Page 103 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.2 1.3.2.1

Man-machine commands for test management TBEI 1. Command function To perform instant test for an E1 line on a rack of a site under a BSC. 2. Syntax structure TBEI: {EBSCID, EBSCNAME} {, ESITEID, ESITENM}, RACKNO, PCMNO: SFLPMODE; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 3) ESITEID : site identification. Signless integer, value range: 1~1024. 4) ESITENM : site name. Character string. Integer type, the maximum length of the character string is 20. 5) RACKNO: rack number Signless integer, value range: 1~8. 6) PCMNO (PCM No): E1 line number. Signless integer, value range: 1~6. 7) SFLPMODE: selfloop mode. Signless integer, value range: 0, 1, among them, 0 is manual selfloop, 1 is automatic selfloop, the default value is 1.

1.3.2.2

TBLI 1. Command function

Page 104 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To perform instant test for the link from a multi-unit (unit) to the MP under a BSC. 2. Syntax structure TBLI: {EBSCID, EBSCNAME}, MUNITNO, UNITNO; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 3) MUNITNO (MUnit No): multi-unit name. Signless integer, value range: 1~127. 4) UNITNO (Unit No ): unit name. Signless integer, value range: 0~20, the default value is 0. 1.3.2.3 TBSA 1. Command function To activate the routine test of a BSC. 2. Syntax structure TBSA: {EBSCID, EBSCNAME}; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40.
Page 105 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.3.2.4

TBSC 1. Command function To create a routine test for a BSC. 2. Syntax structure TBSC: {EBSCID, EBSCNAME}: TESTTIME, tESTSTEP, SETDATE, SETTIME: TESTUNIT, tMPULK, tMPMPLK; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 3) TESTTIME (Test Time): starting time of the routine test. Second -order time type. 4) TESTSTEP (Test Step): time interval of the routine test ( unit: day). Signless integer value, value range: 1~65535. 5) SETDATE (Set Date): set date of the routine test. Date type. 6) SETTIME (Set Time): set time of the routine test. Second-order time type. 7) TESTUNIT (Unit Test Item): multi-unit/unit test item (multiunit - unit name). Composite signless integer, value range: 0~127, the default value is NULL. 8) TMPULK (MP-Unit Link Test Item): test item of the link from the MP to the multi-unit/unit (multiunit - unit name). Composite signless integer, value range: 0~127, the default value is NULL.

Page 106 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) TMPMPLK (MP-MP Link Test Item): test item of the link from the central module MP to the peripheral module MP (peripheral module number) Composite signless integer, value range: 2 to 64, the default value is NULL. 1.3.2.5 TBSD 1. Command function To delete the routine test of a BSC. 2. Syntax structure TBSD: {EBSCID, EBSCNAME}; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 1.3.2.6 TBSQ 1. Command function To query the routine test of a BSC. 2. Syntax structure TBSQ: {EBSCID , EBSCNAME}; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255.

Page 107 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 1.3.2.7 TBSS 1. Command function To suspend the routine test of a BSC. 2. Syntax structure TBSS: {EBSCID, EBSCNAME}; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40. 1.3.2.8 TBUI 1. Command function To perform instant test for a multi-unit (unit) under a BSC. 2. Syntax structure TBUI: {EBSCID, EBSCNAME}, MUNITNO, UNITNO; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40.
Page 108 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MUNITNO (MUnit No): multi-unit name. Signless integer, value range: 1~127. 4) UNITNO (Unit No): unit name. Signless integer, value range: 0~20, the default value is 0. 1.3.2.9 TTRD 1. Command function To delete the test result. 2. Syntax structure TTRD: {EBSCID, EBSCNAME}: TESTTYPE, tESTMODE, tRESULT, tOBJECT, SFLPMODE, [TBGNDATE, tBGNTIME], [TENDDATE, tENDTIME]; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255, the default value is ALL. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40, the default value is ALL. 3) TESTTYPE: test type. Enumerated type, value range: UNIT (multi-unit test) , LINK (link test) , UNIT_LINK (multi-unit test and link test), the default value is ALL. 4) TESTMODE: test mode. Enumerated type, value range: INSTANT ( instant test) , SCHEDULE ( routine test), the default value is ALL. 5) TRESULT: test result. Enumerated type, value range: NORMAL (normal result) , ABNORMAL (abnormal result), the default value is ALL. 6) TOBJECT: test object. Composite enumerated type, value range: DRT (DRT unit) , DTI (DTI unit) , SMT1 (SMT1 unit) , SMT2 (SMT2 unit) ,
Page 109 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

BOSN (BOSN unit) , AIPP (AIPP multi-unit) , BIPP (BIPP multi-unit) , FSPP (FSPP multi-unit) , NSPP (NSPP multi-unit) , TCPP (TCPP multiunit), the default value is ALL. 7) TBGNDATE (Test Begin Date): starting date. Date type, the default value is ALL. 8) TBGNTIME (Test Begin Time): starting time. Second-order time type, the default value is ALL. 9) TENDDATE (Test End Date): ending date. Date type, the default value is ALL. 10) TENDTIME (Test End Time): ending time. Second-order time type, the default value is ALL. 1.3.2.10 TTRQ 1. Command function To query the test result. 2. Syntax structure TTRQ: {EBSCID, EBSCNAME}: TESTTYPE, tESTMODE, tRESULT, tOBJECT, SFLPMODE, [TBGNDATE, tBGNTIME], [TENDDATE, tENDTIME]; 3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255, the default value is ALL. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40, the default value is ALL.

Page 110 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) TESTTYPE: test type. Enumerated type, value range: UNIT (multi-unit test) , LINK (link test) , UNIT_LINK (multi-unit test and link test), the default value is ALL. 4) TESTMODE: test mode. Enumerated type, value range: INSTANT ( instant test) , SCHEDULE ( routine test), the default value is ALL. 5) TRESULT: test result. Enumerated type, value range: NORMAL (normal result) , ABNORMAL (abnormal result), the default value is ALL. 6) TOBJECT: test object. Composite enumerated type, value range: DRT (DRT unit) , DTI (DTI unit) , SMT1 (SMT1 unit) , SMT2 (SMT2 unit) , BOSN (BOSN unit) , AIPP (AIPP multi-unit) , BIPP (BIPP multi-unit) , FSPP (FSPP multi-unit) , NSPP (NSPP multi-unit) , TCPP (TCPP multiunit), the default value is ALL. 7) TBGNDATE (Test Begin Date): starting date. Date type, the default value is ALL. 8) TBGNTIME (Test Begin Time): starting time. Second-order time type, the default value is ALL. 9) TENDDATE (Test End Date): ending date. Date type, the default value is ALL. 10) TENDTIME (Test End Time): ending time. Second-order time type, the default value is ALL. 1.3.2.11 TTXI 1. Command function To perform RF loop instant test for a TRX of a site under a BSC. 2. Syntax structure TTXI: {EBSCID, EBSCNAME} {, ESITEID, ESITENM}, SHELFNO, PANELNO: TESTTIME, tESTCODE; RACKNO,

Page 111 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID: BSC equipment identification. Signless integer, value range: 1~255, the default value is ALL. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40, the default value is ALL. 3) ESITEID : site identification. Signless integer, value range: 1~1024. 4) ESITENM : site name. Character string. Integer type, the maximum length of the character string is 20. 5) RACKNO: rack number Signless integer, value range: 1~8. 6) SHELFNO: shelf number. Signless integer, value range: 1~3. 7) PANELNO: panel number. Signless integer, value range: 1~6. 8) TESTTIME (Test Time): : test duration. Signless integer, value range: 1~1200. Unit: second. 9) TESTCODE: test code type. Signless integer, value range: 0, 1. 2, among them, 0: all are 0, 1: all are 1, 2: random. 1.3.2.12 TTXS 1. Command function To cancel RF loop instant test for a TRX of a site under a BSC. 2. Syntax structure TTXS: {EBSCID, EBSCNAME} {, ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO; 3. Parameter description

Page 112 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCIDNAME: BSC equipment identification. Signless integer, value range: 1~255, the default value is ALL. 2) EBSCNAME: BSC equipment name. Character string type, the maximum length of the character string is 40, the default value is ALL. 3) ESITEID : site identification. Signless integer, value range: 1~1024. 4) ESITENM : site name. Character string. Integer type, the maximum length of the character string is 20. 5) RACKNO: rack number Signless integer, value range: 1~8. 6) SHELFNO: shelf number. Signless integer, value range: 1~3. 7) PANELNO: panel number. Signless integer, value range: 1~6.

1.4
1.4.1 1.4.1.1

Performance management
Man-machine commands of measurement jobs PMCQ 1. Command function To query the current value of a specified counter of a specified object for a measurement job. 2. Syntax structure PMCQ: BSSID, NAME: OBJECT, COUNTNO; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value .

Page 113 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) NAME (Measurement Job Name): name of the measurement job to be queried. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, no default value . 3) OBJECT (Measured Object): object of the counter. Signless integer, a single integer number, value range: 0~1024. The meaning of the parameter depends on the type of the measured object. If the measured object is a SITE, module or signaling No .7 link, the format of the value is X (X is the SITE, module or signaling No.7 link number); if the measured object is a CELL, the value format is X-X (X represents respectively the SITE number and CELL number); if the measured object is a TRX, the value format is X-X-X (X represents respectively the SITE number, CELL number and TRX number); if the measured object is a BSC, the value can only be the default BSC. 4) COUNTNO: counter number. Signless integer, value range: 0~99999, no default value. 1.4.1.2 PMIQ 1. Command function To query the parameter information of multiple measurement jobs under a BSS. 2. Syntax structure PMIQ: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value. 2) NAME (Measurement Job Name): name of the measurement job to be queried. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, and the default value is ALL, in this case, the brief information of all jobs will be returned (without including the reported information, measured object and measurement time period).
Page 114 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.4.1.3

PMJC 1. Command function To create a measurement job. 2. Syntax structure PMJC: BSSID: NAME, tYPE: OBJECT: BGNDATE, ENDDATE, DAY, INTERVAL, GP: FRDATE, FRTIME, RP; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value . 2) NAME (Measurement Job Name): the name of the measurement job to be created. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, no default value. 3) TYPE (Measurement Job Type): the type of the measurement job to be created.. Signless integer, the default value is 0. 4) OBJECT: measured object. Composite signless integer, a single integer number, value range: 0~1024, the default value is ALL, representing all the corresponding measured object under the BSC. The meaning of the parameter depends on the type of the measured object. If the measured object is a SITE, module or signaling No .7 link, the format of the value is X (X is the SITE, module or signaling No.7 link number); if the measured object is a CELL, the value format is X-X (X represents respectively the SITE number and CELL number); if the measured object is a TRX, the value format is X-X-X (X represents respectively the SITE number, CELL number and TRX number); if the measured object is a BSC, the value can only be the default BSC. 5) BGNDATE (Begin Date): starting date for measurement. Date type, the default value is CURDATE, representing the current date .

Page 115 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) ENDDATE (End Date): ending date for measurement. Date type, it must be later than the starting date for measurement, the default value is ENDLESS, representing not to end automatically. 7) DAY (Measurement Day): measurement day of each week. Composite enumerated type, value range: SUN, MON, TUE, WED, THU, FRI, SAT, the default value is ALL. 8) INTERVAL (Measurement Interval): measurement interval for each day. Composite minute-order time interval type, the default value is 00-00, representing a time interval from 0 oclock to 24 oclock. 9) GP (Granularity Period): granularity period for measurement. Time duration type, value range: 5N, 15N, 30N, 60N, the default value is 5N (5 minute). 10) FRDATE : first report date. Date type, the default value is NONE, representing the earliest possible report time. 11) FRTIME: first report time. Minute-order time type. It sets up the first report time together with the first report date, and must be later than the earliest possible report time. The default value is NONE, representing the earliest possible report time. 12) RP: report period. Time duration type. It must be an integral multiple of the granularity period for measurement. Value range: 0N, 15N, 30N, 60N, 6H, 12H, 24H, the default value is 0, representing to report immediately. 1.4.1.4 PMJD 1. Command function To delete multiple measurement jobs under a BSS. 2. Syntax structure PMJD: BSSID, NAME;
Page 116 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value . 2) NAME (Measurement Job Name): the names of the measurement jobs to be deleted. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL. 1.4.1.5 PMJM 1. Command function To modify a measurement job. 2. Syntax structure PMJM: BSSID, NAME: NEWNAME: BGNDATE, ENDDATE, DAY, INTERVAL: FRDATE, FRTIME, RP; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value . 2) NAME (Measurement Job Name): the name of the measurement job to be modified. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, no default value. 3) NEWNAME: new measurement job name. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, the default value is UNCHANGE, representing not to change. 4) BGNDATE (Begin Date): new starting date for measurement. Date type. If the job has been started, it is forbidden to modify this item. The default value is UNCHANGE, representing not to change.

Page 117 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) ENDDATE (End Date): new ending date for measurement. Date type. It must be later than the starting date for measurement. The default value is UNCHANGE, representing not to change. To change it as not to end automatically, set the parameter to 2038-1-1. 6) DAY (Measurement Day): new measurement day of each week. Composite enumerated type, value range: SUN, MON, TUE, WED, THU, FRI, SAT, the default value is UNCHANGE, representing not to change. 7) INTERVAL (Measurement Interval): new measurement interval of each day. Composite minute-order time interval type, the default value is UNCHANGE, representing not to change. 8) FRDATE (First Report Date): new first report date. Date type. It is forbidden to be modified if it has been reported. The default value is UNCHANGE, representing not to change. 9) FRTIME (First Report Time): new first report time. Minute-order time type. It sets up the first report time together with the first report date, and must be later than the earliest possible report time. It is forbidden to be modified if it has been reported. The default value is UNCHANGE, representing not to change. 10) RP (Report Period): new report period. Time duration type. It must be an integral multiple of the granularity period for measurement. Value range: 0N, 15N, 30N, 60N, 6H, 12H, 24H, the default value is UNCHANGE, representing not to change. 1.4.1.6 PMJQ 1. Command function To query the names of all current measurement jobs under a BSS. 2. Syntax structure PMJQ: BSSID; 3. Parameter description
Page 118 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value. 1.4.1.7 PMJR 1. Command function To restore multiple measurement jobs under a BSS. 2. Syntax structure PMJR: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value . 2) NAME (Measurement Job Name): the names of the measurement jobs to be restored. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL. 1.4.1.8 PMJS 1. Command function To suspend multiple measurement jobs under a BSS. 2. Syntax structure PMJS: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value .

Page 119 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) NAME (Measurement Job Name): the names of the measurement jobs to be suspended. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL. 1.4.2 1.4.2.1 Man-machine commands of observation jobs POIQ 1. Command function To query the parameter information of multiple observation jobs under a BSS. 2. Syntax structure POIQ: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): name of the observation job to be queried. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, and the default value is ALL, representing that the brief information of all jobs will be returned (without including the observed object). 1.4.2.2 POJC 1. Command function To create an observation job. 2. Syntax structure POJC: BSSID: NAME, tYP E: OBJECT: ENDDATE, ENDTIME;
Page 120 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): the name of the observation job to be created. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, no default value . 3) TYPE (Observation Job Type): the type of the observation job to be created. Signless integer, the default value is 0. 4) OBJECT: observed object. Composite signless integer, a single integer number, value range: 0~1024, no default value . The meaning of the parameter depends on the type of the observed object, and the type of all observed objects at present is CELL, whose value format is X-X (X represents respectively the SITE ID number and CELL ID number). A job can have only one observed object. 5) ENDDATE (End Date): ending date for observation. Date type, the default value is ENDLESS, representing not to end automatically. 6) ENDTIME (End Time): ending time for observation. Minute-order time type. It forms the ending time together with the ending date, and must be later than the current time for creation, the default value is NONE, representing 00: 00. 1.4.2.3 POJD 1. Command function To delete multiple observation jobs under a BSS. 2. Syntax structure POJD: BSSID, NAME; 3. Parameter description
Page 121 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): the name of the observation job to be deleted. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL. 1.4.2.4 POJM 1. Command function To modify a observation job. 2. Syntax structure POJM: BSSID, NAME: NEWNAME: ENDDATE, ENDTIME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): the name of the observation job to be created. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, no default value . 3) NEWNAME: new observation job name. Character string type, the maximum length of the character string is 50 bytes, the minimum length is 1 byte, the default value is UNCHANGE, representing not to change. 4) ENDDATE (End Date): ending date for observation. Date type, the default value is ENDLESS, representing not to end automatically. 5) ENDTIME (End Time): ending time for observation. Minute-order time type. It forms the ending time together with the ending date, and must be later than the current time for creation, the default value is NONE, representing 00: 00.
Page 122 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.4.2.5

POJQ 1. Command function To query the names of all current observation jobs under a BSS. 2. Syntax structure POJQ: BSSID; 3. Parameter description BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value.

1.4.2.6

POJR 1. Command function To restore multiple observation jobs under a BSS. 2. Syntax structure POJR: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): the name of the observation job to be restored. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL.

1.4.2.7

POJS 1. Command function


Page 123 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To suspend multiple observation jobs under a BSS. 2. Syntax structure POJS: BSSID, NAME; 3. Parameter description 1) BSSID (Bss ID): BSS ID number of the observation job. Signless integer, value range: 1~255, no default value . 2) NAME (Observation Job Name): the name of the observation job to be suspended. Composite character string type, the maximum length of each character string is 50 bytes, the minimum length is 1 byte, the default value is ALL. 1.4.3 1.4.3.1 Man-machine commands of alarm threshold PTIQ 1. Command function To query the threshold parameters of QoS alarm monitoring. 2. Syntax structure PTIQ: BSSID; 3. Parameter description BSSID (BSS ID): BSS ID number of the QoS alarm monitoring. Signless integer, value range: 1~255, no default value . 1.4.3.2 PTRM 1. Command function To modify the threshold parameters of QoS alarm monitoring.
Page 124 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure PTRM: BSSID: [RMLLT] [, RMLGP] [, RMLEN] [, RPLLT] [, RPLGP] [, RPLEN] [, SMLLT] [, SMLGP] [, SMLEN] [, SPLLT] [, SPLGP] [, SPLEN] [, CSRLT] [, CSRGP] [, CSREN] [, N7ASRLT] [, N7ASRGP] [, N7ASREN] [, tFARLT] [, tFARGP] [, tFAREN] [, tHARLT] [, tHARGP] [, tHAREN] [, SDARLT] [, SDARGP] [, SDAREN] [, N7ARLT] [, N7ARGP] [, N7AREN] [, tFMTLLT] [, tFMTLGP] [, tFMTLEN] [, tHMTLLT] [, tHMTLGP] [, tHMTLEN] [, N7MTLLT] [, N7MTLGP] [, N7MTLEN] [, SDDRLT] [, SDDRGP] [, SDDREN] [, FAFDRLT] [, FAFDRGP] [, FAFDREN] [, FAHDRLT] [, FAHDRGP] [, FAHDREN] [, tFVDRLT] [, tFVDRGP] [, tFVDREN] [, tFDDRLT] [, tFDDRGP] [, tFDDREN] [, tHVDRLT] [, tHVDRGP] [, tHVDREN] [, tHDDRLT] [, tHDDRGP] [, tHDDREN] [, IHOSRLT] [, IHOSRGP] [, IHOSREN] [, OHOSRLT] [, OHOSRGP] [, OHOSREN] [, IBHOSRLT] [, IBHOSRGP] [, IBHOSREN] [, ICHOSRLT] [, ICHOSRGP] [, ICHOSREN]; 3. Parameter description 1) BSSID (BSS ID): BSS ID number of the QoS alarm monitoring. Signless integer, value range: 1~255, no default value. 2) RMLLT: RMM CP Mean Load Limit. Percent integer type, value range: 0% to 100%, no default value . 3) RMLGP: RMM CP Mean Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 4) RMLEN: RMM CP Mean Load Enabled. Type Boolean, no default value. 5) RPLLT: RMM CP Peak Load Limit. Percent integer type, value range: 0% to 100%, no default value . 6) RPLGP: RMM CP Peak Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 7) RPLEN: RMM CP Peak Load Enabled. Type Boolean, no default value.

Page 125 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) SMLLT: SMM CP Mean Load Limit. Percent integer type, value range: 0% to 100%, no default value . 9) SMLGP: SMM CP Mean Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 10) SMLEN: SMM CP Mean Load Enabled. Type Boolean, no default value. 11) SPLLT: SMM CP Peak Load Limit. Percent integer type, value range: 0% to 100%, no default value . 12) SPLGP: SMM CP Peak Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 13) value. SPLEN: SMM CP Peak Load Enabled. Type Boolean, no default

14) CSRLT: Call Establishment Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 15) CSRGP: Call Establishment Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 16) CSREN: Call Establishment Success Rate Enabled. Type Boolean, no default value. 17) N7ASRLT: No. 7 Trunk Assignment Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value . 18) N7ASRGP: No. 7 Trunk Assignment Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 19) N7ASREN: No. 7 Trunk Assignment Success Rate Enabled. Type Boolean, no default value. 20) TFARLT: TCH/F Available Rate Limit. Percent integer type, value range: 0% to 100%, no default value.
Page 126 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

21) TFARGP: TCH/F Available Rate Granularity Period. Time type, value range: 5N, 15N, 30N, 60N, no default value. 22) TFAREN: TCH/F Available Rate Enabled. Type Boolean, no default value. 23) THARLT: TCH/H Available Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 24) THARGP: TCH/H Available Rate Granularity Period. Time type, value range: 5N, 15N, 30N, 60N, no default value. 25) THAREN: TCH/H Available Rate Enabled. Type Boolean, no default value. 26) SDARLT: SDCCH Available Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 27) SDARGP: SDCCH Available Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 28) SDAREN: SDCCH Available Rate Enabled. Type Boolean, no default value. 29) N7ARLT: No. 7 Trunk Available Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 30) N7ARGP: No. 7 Trunk Available Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 31) N7AREN: No. 7 Trunk Available Rate Enabled. Type Boolean, no default value. 32) TFMTLLT: TCH/F Mean Traffic Load Limit. Floating -point type, value range: 0, 1. no default value . 33) TFMTLGP: TCH/F Mean Traffic Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value .
Page 127 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

34) TFMTLEN: TCH/F Mean Traffic Load Enabled. Type Boolean, no default value. 35) THMTLLT: TCH/H Mean Traffic Load Limit. Floating-point type, value range: 0, 1. no default value . 36) THMTLGP: TCH/H Mean Traffic Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 37) THMTLEN: TCH/H Mean Traffic Load Enabled. Type Boolean, no default value. 38) N7MTLLT: No. 7 Trunk Mean Traffic Load Limit. Floating-point type, value range: 0, 1. no default value . 39) N7MTLGP: No. 7 Trunk Mean Traffic Load Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 40) N7MTLEN: No. 7 Trunk Mean Traffic Load Enabled. Type Boolean, no default value. 41) SDDRLT: SDCCH Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value . 42) SDDRGP: SDCCH Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 43) value. SDDREN: SDCCH Drop Rate Enabled. Type Boolean, no default

44) FAFDRLT: FACCH/F Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 45) FAFDRGP: FACCH/F Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 46) FAFDREN: FACCH/F Drop Rate Enabled. Type Boolean, no default value.
Page 128 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

47) FAHDRLT: FACCH/H Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 48) FAHDRGP: FACCH/H Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 49) FAHDREN: FACCH/H Drop Rate Enabled. Type Boolean, no default value. 50) TFVDRLT: TCH/F Voice Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 51) TFVDRGP: TCH/F Voice Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 52) TFVDREN: TCH/F Voice Drop Rate Enabled. Type Boolean, no default value. 53) TFDDRLT: TCH/F Data Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 54) TFDDRGP: TCH/F Data Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 55) TFDDREN: TCH/F Data Drop Rate Enabled. Type Boolean, no default value. 56) THVDRLT: TCH/H Voice Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value. 57) THVDRGP: TCH/H Voice Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 58) THVDREN: TCH/H Voice Drop Rate Enabled. Type Boolean, no default value. 59) THDDRLT: TCH/H Data Drop Rate Limit. Percent integer type, value range: 0% to 100%, no default value.
Page 129 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

60) THDDRGP : TCH/H Data Drop Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 61) THDDREN: TCH/H Data Drop Rate Enabled. Type Boolean, no default value. 62) IHOSRLT: Incoming Handover Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value . 63) IHOSRGP: Incoming Handover Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value . 64) IHOSREN: Incoming Handover Success Rate Enabled. Type Boolean, no default value. 65) OHOSRLT: Outgoing Handover Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value . 66) OHOSRGP: Outgoing Handover Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 67) OHOSREN: Outgoing Handover Success Rate Enabled. Type Boolean, no default value. 68) IBHOSRLT: Intra-BSS Handover Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value . 69) IBHOSRGP: IntraBSS Handover Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 70) IBHOSREN: IntraBSS Handover Success Rate Enabled. Type Boolean, no default value. 71) ICHOSRLT: IntraCell Handover Success Rate Limit. Percent integer type, value range: 0% to 100%, no default value .

Page 130 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

72) ICHOSRGP: IntraCell Handover Success Rate Granularity Period. Time duration type, value range: 5N, 15N, 30N, 60N, no default value. 73) ICHOSREN: IntraCell Handover Success Rate Enabled. Type Boolean, no default value. 1.4.3.3 PTRR 1. Command function To restore the QoS alarm monitoring under a BSS. 2. Syntax structure PTRR: BSSID; 3. Parameter description BSSID (BSS ID): BSS ID number of the QoS alarm monitoring. Signless integer, value range: 1~255, no default value . 1.4.3.4 PTRS 1. Command function To suspend the QoS alarm monitoring under a BSS. 2. Syntax structure PTRS: BSSID; 3. Parameter description BSSID (BSS ID): BSS ID number of the QoS alarm monitoring. Signless integer, value range: 1~255, no default value .

Page 131 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.4.4 1.4.4.1

Other man-machine commands PBMQ 1. Command function To query the ID numbers of all BTSs (CELLs) and their modules under a BSS. 2. Syntax structure PBMQ: BSSID; 3. Parameter description BSSID (Bss ID): specified BSS ID number. Signless integer, value range: 1~255, no default value.

1.4.4.2

PBSQ 1. Command function To query all BSSs. 2. Syntax structure PBSQ; 3. Parameter description None.

1.4.4.3

PBTQ 1. Command function To query the ID numbers of all BTSs (CELLs) under a BSS.

Page 132 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure PBTQ: BSSID; 3. Parameter description BSSID (Bss ID): specified BSS ID number. Signless integer, value range: 1~255, no default value. 1.4.4.4 PLKQ 1. Command function To query all SS7 link numbers under a BSS. 2. Syntax structure PLKQ: EBSSID; 3. Parameter description EBSSID (EBss ID): specified EBSS ID number. Signless integer, value range: 1~255, no default value. 1.4.4.5 PMOS 1. Command function To synchronize the background performance data to a specified module under a specified BSS of the foreground.. 2. Syntax structure PMOS: BSSID: MODULENO; 3. Parameter description

Page 133 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSID (Bss ID): BSS ID number of the measurement job. Signless integer, value range: 1~255, no default value . 2) MODULENO: module number. Signless integer, value range: 1~9, the default value is 1. 1.4.4.6 PPIQ 1. Command function To query performance indexes. 2. Syntax structure PPIQ; 3. Parameter description None. 1.4.4.7 PSIQ 1. Command function To query all SITE numbers under a BSS. 2. Syntax struc ture PSIQ: BSSID; 3. Parameter description BSSID (Bss ID): specified BSS ID number. Signless integer, value range: 1~255, no default value. 1.4.4.8 PSMQ 1. Command function
Page 134 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To query the ID numbers of all SITEs and their modules under a BSS. 2. Syntax structure PSMQ: BSSID; 3. Parameter description BSSID (Bss ID): specified BSS ID number. Signless integer, value range: 1~255, no default value. 1.4.4.9 PTXQ 1. Command function To query all TRX numbers under a BSS. 2. Syntax structure PTXQ: BSSID; 3. Parameter description BSSID (Bss ID): specified BSS ID number. Signless integer, value range: 1~255, no default value.

1.5
1.5.1 1.5.1.1

Configuration management
Man-machine commands of radio resources management RAHC 1. Command function To add an adjacent cell handover object. 2. Syntax structure

Page 135 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RAHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: AHID: SYNC, PRI, MTPMAX, RLMIN: ISRCELL, NCLAYER: RHOECMO; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) AHID (Adjacent Cell HandOver Identification): identification number of adjacent cell handover object. Signless integer, value range: 33 to 64. 7) SYNC (Synchronize): indicating whether to synchronize the current cell with adjacent cells. Type Boolean, with a value of T or F. The default value is T. 8) PRI (Priority): priority level for cell handover. Signless integer, value range: 0~7, the default value is 3. 9) MTPMAX (Ms Transit Power Max): maximum transmitting power of MS in the adjacent cell. Signless integer, value range: 1~31, the default value is 5. 10) RLMIN ( Receive Level Min): minimum signal level for MS to receive in the handover target cell. Signless integer, value range: 0~63, the default value is 15.

Page 136 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) ISRCELL (Is Relative Cell): indicating whether the current cell and adjacent cell are related cells. Type Boolean, with a value of T or F, the default value is F. 12) NCLAYER (NC Layer): neighboring cell layer. Signless integer, value range: 0~3, the default is 0. 13) RHOECMO (RHOECMO): DN of the handover cell (HOC): BssId-SiteId -BtsId-HoId or DN of external cells : EcId. Composite signless integer. 1.5.1.2 RAHD 1. Command function To delete the adjacent cell handover object of a cell. 2. Syntax structure RAHD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, AHID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40.

Page 137 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) AHID (Adjacent Cell HandOver Identification): identification number of adjacent cell handover object. Signless integer, value range: 33 to 64. 1.5.1.3 RAHM 1. Command function To modify the radio parameters of an adjacent cell handover object. 2. Syntax structure RAHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, AHID: [SYNC] [, PRI] [, MTPMAX] [, RLMIN] [, ISRCELL] [, NCLAYER]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) AHID (Adjacent Cell HandOver Identification): identification number of adjacent cell handover object. Signless integer, value range: 33 to 64. 7) SYNC (Synchronize): indicating whether to synchronize the current cell with adjacent cells. Type Boolean, with a value of T or F, the default value is T.

Page 138 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) PRI (Priority): priority level for cell handover. Signless integer, value range: 0~7, the default value is 3. 9) MTPMAX (Ms Transit Power Max): maximum transmitting power of MS in the adjacent cell. Signless integer, value range: 1~31, the default value is 5. 10) RLMIN ( Receive Level Min): minimum signal level for MS to receive in the handover target cell. Signless integer, value range: 0~63, the default value is 15. 11) ISRCELL (Is Relative Cell): indicating whether the current cell and adjacent cell are related cells. Type Boolean, with a value of T or F, the default value is F. 12) NCLAYER (NC Layer): neighboring cell layer. Signless integer, value range: 0~3, the default is 0. 1.5.1.4 RAHQ 1. Command function To view the parameters of an adjacent cell handover object. 2. Syntax structure RAHQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, AHID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024.

Page 139 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) AHID (Adjacent Cell HandOver Identification): identification number of adjacent cell handover object. Signless integer, value range: 33 to 64. 7) PARAGRP (Parameter Group): radio parameter attribute package type. Enumerated type. Value range: ALL, the default value is ALL. 1.5.1.5 RARC 1. Command function To add a new adjacent cell reselection object. 2. Syntax structure RARC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: ARID: RBTSECMO; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40.

Page 140 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) ARID (AdjacentCellReselection Identification): identification number of adjacent cell reselection object. Signless integer, value range: 1 to 32. 7) RBTSECMO (Related BTS or ExternalCell Managed Object): DN of the related BTS: BssId -SiteId -BtsId or DN of an external cell under this BSS: EcId. Composite signless integer. 1.5.1.6 RARD 1. Command function To delete the adjacent cell reselection object of a cell. 2. Syntax structure RARD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: ARID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3.

Page 141 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) ARID (AdjacentCellReselection Identification): identification number of adjacent cell reselection object. Signless integer, value range: 1 to 32. 1.5.1.7 RARQ 1. Command function To view the parameters of an adjacent cell reselection object. 2. Syntax structure RARQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, ARID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the maximum length is 40. 6) ARID (AdjacentCellReselection Identification): identification number of adjacent cell reselection object. Signless integer, value range: 1 to 32.

Page 142 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) PARAGRP (Parameter Group): radio parameter attribute package type. Enumerated type. Value range: ALL, the default value is ALL. 1.5.1.8 RBCA 1. Command function To modify the radio status attribute of a radio BSC. 2. Syntax structure RBCA: {BSCID, BSCNAME}: AD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) BSCNAME (BSC Name): BSC identification name. Character string type, the maximum length is 40. 3) AD (Administer State): administration state attribute.. Enumerated type, enumerated items: L, U, S. 1.5.1.9 RBCC 1. Command function To add a functional BSC. 2. Syntax structure RBCC: BSCID: ALIAS: BARANG: MCC, MNC: INTERHO, INTRAHO, OVERLEV, FUNCEXT: T1, t3, t4, t7, t8, t10, t13, t17, t18, t19, t20: T9101, t9103, t9104, t9105, t9108, t9113, ZXGT1, ZXGT2, ZXGT3, ZXGT4, ZXGT5, ZXGT6, ZXGT7, ZXGT8, ZXGT9, ZXGT10, ZXGT11, RMSTQHO, ZXGT12, ZXGT13, ZXGT14, ZXGT15, ZXGT16, ZXGMT7, ZXGMT11, ZXGMT12, tMICRO, tBSIC, AIST1, AIST4, AIST8, AIST12, BCRT, BCPT:
Page 143 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

T3101, t3103, t3107, t3109, t3111, t3113, t3105: BMRN, CMRN, CONFUMSG: RINDTHS, LOADIND, LVT, LIP, EDRAF, ACE: LOCNAME: CELFCTHS, MSFCTHS, CELFCPER, MSFCPER, DELAY, NSBLKMX, NSUNBLKM, NSALIV EM, BVCBLKM, BVCUBLKM, BVCRESTM, SUSPENDM, RESUMEM, UPDATEM, FLRPTPRD, CN, XN, NN, OVERLDTH, DEFRATE, N3101, N3103, N3105: T3169, t3191, t3193, t3195, BSSGPT1, BSSGPT2, BSSGPT3, BSSGPT4, BSSGPT5, NS_T1, NS_T2, NS_T3, NS_T4, NS_T5 ccmT1, ccmT2, ccmT3, csMode; 3. Parameter description 1) BSCID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) ALIAS (Alias): alias. Character string type, the maximum length is 40. 3) BARANG (Band Range): broadcast range. Composite integer type, value range: 1~124, 0, 512 to 885, 975 to 1023. 4) MCC (Mobile Country Code): Mobile country code. Signless integer, value range: 0~999, the default value is 460 (China). 5) MNC (Mobile NetWork Code): mobile network code. Signless integer, value range: 0~99, the default value is 0. 6) INTERHO (Inter-cell HandOver): whether to allow inter-cell handover. Type Boolean, the default value is T. 7) INTRAHO (Intra-HandOver): whether to allow intra-cell handover. Type Boolean, the default value is T. 8) OVERLEV (OverFlow Level): flow control. Signless integer, value range: 0, the default value is 0. 9) FUNCEXT: whether the system supports PCS1900. Signless integer, 0: support DCS1800, 1: support PCS1900. 10) T1 (Time1): blocking/unblocking period. Signless integer, value range: 30~150, the default value is 80.
Page 144 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) T3 (Time3): protection time of instantaneous disconnection. Signless integer, value range: 10~200, the default value is 100. 12) T4 (Time4): global reset period. Signless integer, value range: 60~150, the default value is 100. 13) T7 (Time7): protection period of handover request. Signless integer, value range: 100~200, the default value is 100. 14) T8 (Time8): execution period of source BSC handover. Signless integer, value range: 50~700, the default value is 120. 15) T10 (Time10): assignment period. Signless integer, value range: 40~150, the default value is 80. 16) T13 (Time13): protection period of global reset. Signless integer, value range: 30~60, the default value is 40. 17) T17 (Time17): the first overload period of flow control. Signless integer, value range: 30~150, the default value is 80. 18) T18 (Time18): the second overload period of flow control. Signless integer, value range: 100~300, the default value is 150. 19) T19 (Time19): reset period of the circuit at the BSS side. Signless integer, value range: 30~150, the default value is 80. 20) T20 (Time20): blocking/unblocking period of circuit group. Signless integer, value range: 30~150, the default value is 80. 21) T9101 (Time9101): monitoring the receiving of RLSD messages. Signless integer, value range: 20~50, the default value is 20. 22) T9103 (Time9103): monitoring the channel activation process. Signless integer, value range: 20, the default value is 20. 23) T9104 (Time9104): monitoring the CLEAR command sent from MSC. Signless integer, value range: 20~50, the default value is 30.
Page 145 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

24) T9105 (Time9105): monitoring the SCCP connection process. Signless integer, value range: 20~60, the default value is 30. 25) T9108 (Time9108): monitoring the physical context request process. Signless integer, value range: 20, the default value is 20. 26) T9113 (Time9113): monitoring the external handover process in the target cell. Signless integer, value range: 50~180, the default value is 110. 27) ZXGT1 (ZX Gsm Timer1): the protection time for waiting for the access of MS after the channel is activated during assignment or handover. Signless integer, value range: 50~120, the default value is 70. 28) ZXGT2 (ZX Gsm Timer2): protection time of channel application. Signless integer, value range: 20~50, the default value is 40. 29) ZXGT3 (ZX Gsm Timer3): the protection time for waiting for the link establishment response of the central module during immediate assignment. Signless integer, value range: 30~100, the default value is 60. 30) ZXGT4 (ZX Gsm Timer4): monitoring the modification process of MS channel mode. Signless integer, value range: 10~80, the default value is 30. 31) ZXGT5 (ZX Gsm Timer5): monitoring the modification process of encryption mode. Signless integer, value range: 30~120, the default value is 100. 32) ZXGT6 (ZX Gsm Timer6): monitoring the link establishment of SAPI3. Signless integer, value range: 10~300, the default value is 100. 33) ZXGT7 (ZX Gsm Timer7): the protection time for waiting for the response of P0 to assignment or the handover completion message. Signless integer, value range: 50~200, the default value is 150. 34) ZXGT8 (ZX Gsm Timer8): the time from the handover command to the clear command during outgoing handover. Signless integer, value range: 50~650, the default value is 100.
Page 146 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

35) ZXGT9 (ZX Gsm Timer9): the protection time from the handover command to the clear command during outgoing handover. Signless integer, value range: 10~50, the default value is 20. 36) ZXGT10 (ZX Gsm Timer10): the queuing protection time for channel application.. Signless integer, value range: 50~200, the default value is 130. 37) ZXGT11 (ZX Gsm Timer11): the maximum allowed queuing time for assignment attempt. Signless integer, value range: 10~150, the default value is 60. 38) RMSTQHO (Retry Ms Timer Queue HandOver): the maximum allowed queuing time for handover attempt. Signless integer, value range: 10~150, the default value is 50. 39) ZXGT12 (ZX Gsm Timer12): periodic status acknowledgement interval. Signless integer, value range: 100~18000, the default value is 3000. 40) ZXGT13 (ZX Gsm Timer13): monitoring the modification process of BTS and MS modes. Signless integer, value range: 35 to 100, the default value is 60. 41) ZXGT14 (ZX Gsm Timer14): the period of time from the moment when the target instance sends an assignment/handover command to the moment when the acknowledgement is received. Signless integer, value range: 10~50, the default value is 20. 42) ZXGT15 (ZX Gsm Timer15): the time taken for the target instance to wait for the availability of resources during forced release.. Signless integer, value range: 10~50, the default value is 30. 43) ZXGT16 (ZX Gsm Timer16): interval time of directional retry. Signless integer, value range: 20~60, the default value is 20. 44) ZXGMT7 (ZX Gsm MTimer7): protection time of external handover. Signless integer, value range: 1~65535, the default value is 100.
Page 147 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

45) ZXGMT11 (ZX Gsm MTimer11): a clock in the overload control. Signless integer, value range: 30~150, the default value is 80. 46) ZXGMT12 (ZX Gsm MTimer12): a clock in the overload control. Signless integer, value range: 50~200, the default value is 150. 47) TMICRO (Timer Micro): time delay timer for micro-micro handover. Signless integer, value range: 50~200, the default value is 80. 48) TBSIC (Timer Bsic): BSIC decoding period. Signless integer, value range: 20~640, the default value is 50. 49) AIST1 (AIS Timer1): Assigning status protection timer. Signless integer, value range: 40~150, the default value is 80. 50) AIST4 (AIS Timer4): RapidApplying status protection timer. Signless integer, value range: 30~150, the default value is 40. 51) AIST8 (AIS Timer8): OutGoHoing status protection timer. Signless integer, value range: 50~700, the default value is 120. 52) AIST12 (AIS Timer12): Serving status protection timer. Signless integer, value range: 100~18000, the default value is 3000. 53) BCRT (BCRT): routine timer for system message broadcast. Signless integer, value range: 6000~864000, the default value is 18000. 54) BCPT (BCPT): protection timer for system message broadcast to wait for the response of FUC. Signless integer, value range: 30~100, the default value is 50. 55) T3101 (T3101): the maximum period of time from the moment when the BSC network side sends an immediate assignment to the moment when the MS acquires a channel successfully. Signless integer, value range: 10~50, the default value is 30. 56) T3103 (T3103): the maximum period of time from the moment when the BSC network side sends an handover to the moment when the
Page 148 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

MS acquires a channel successfully. Signless integer, value range: 35 to 100, the default value is 60. 57) T3107 (T3107): the timer for managing assignment and intra-cell handover. Signless integer, value range: 35 to 100, the default value is 60. 58) T3109 (T3109): the maximum time taken for completely releasing the channel when a low-layer error occurs or the channel release process begins. Signless integer, value range: 10~150, the default value is 0. 59) T3111 (T3111): the time taken from releasing the traffic channel to deactivating the RF channel. Signless integer, value range: 1~5, the default value is 1. 60) T3113 (T3113): time delay timer for micro-micro handover. Signless integer, value range: 0~65535, the default value is 1. 61) T3105 (T3105): T3105 timer. Signless integer, value range: 0, the default value is 0. 62) BMRN (BSC Max Reset No): the maximum number of repetition times for BSC reset process . Signless integer, value range: 1~255, the default value is 3. 63) CMRN (Circuit Max Reset No): the maximum number of repetition times for circuit reset process . Signless integer, value range: 1~255, the default value is 3. 64) CONFUMSG (Confusion M essage): whether to allow BSC to send BSSAP Confusion. Type Boolean, the default value is F. 65) RINDTHS (Resource Indication threshold): the threshold for BSC to spontaneously indicate resources (available channels) to MSC (%). Signless integer, value range: 0~100, the default value is 30. 66) LOADIND: Load Indication. Type Boolean, the default value is T.

Page 149 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

67) LVT: Load Valid Time. Signless integer, value range: 1~255, the default value is 18. 68) LIP: Load Indication Period. Signless integer, value range: 10~65530, the default value is 1500. 69) EDRAF: EDR Assignment Failure. Type Boolean, the default value is F. 70) ACE (ACE): ACE. Type Boolean, the default value is F.

71) LOCNAME (Location Name): resource location information. Character string type, the maximum length is 40. 72) CELFCTHS: BSSGP flow control threshold of the cell. Signless integer, value range: (0~100). 73) MSFCTHS: BSSGP flow control threshold of the MS. Signless integer, value range: (0~100). 74) CELFCPER: BSSGP flow control trigger period of the cell (unit: 10ms). Signless integer. 75) MSFCPER: BSSGP flow control trigger period of the MS (unit: 10ms). Signless integer. 76) DELAY: NS-VC end-to-end time delay (unit: 10ms). Signless integer. 77) NSBLKMX: the maximum number of retry times for Block of NS, NS link-layer parameter. Signless integer, the maximum length is 3. 78) NSUNBLKM: the maximum number of retry times for Unblock of NS, NS link-layer parameter. Signless integer, the maximum length is 3. 79) NSALIVEM: the maximum number of retry times for Alive of NS, NS link-layer parameter. Signless integer, the maximum length is 10.

Page 150 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

80) BVCBLKM: the maximum number of retry times for Block of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 81) BVCUBLKM: the maximum number of retry times for Unblock of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 82) BVCRESTM: the maximum number of retry times for Reset of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 83) SUSPENDM: the maximum number of retry times for Suspend, BSSGP-layer parameter. Signless integer, the maximum length is 3. 84) RESUMEM: the maximum number of retry times for Resume, BSSGP-layer parameter. Signless integer, the maximum length is 3. 85) UPDATEM: the maximum number of retry times for RA_CAPABILITY_UPDATE_RETRIES, BSSGP-layer parameter. Signless integer, the maximum length is 3. 86) FLRPTPRD : reporting period of channel failure rate (unit: 52 multi-frames). Signless integer. 87) CN: when the accumulated number of continuously and correctly received data blocks exceeds the preset parameter CN, the transmitting coding mode of MS will be improved by one level. Signless integer array, the number is 3. 88) XN: when Xn% data blocks have been lost in Nn continuous data blocks, the transmitting coding mode of MS will be reduced by one level.. Signless integer array, the number is 3. 89) NN: when Xn% data blocks have been lost in Nn continuous data blocks, the transmitting coding mode of MS will be reduced by one level.. Signless integer array, the number is 3. 90) OVERLDTH: maximum bearing ideal rate for PS channel (unit: 100b/s). Signless integer.

Page 151 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

91) DEFRATE: default rate for initial access (unit: 100b/s). Signless integer. 92) N3101: when USF has been set on the network, if no effective data has been received for N3101 continuous blocks, the network will regard the TBF quality as being too poor, and the TBF will be released.. Signless integer. 93) N3103: if the network has not received the Packet Control Ack message for N3103 times in specified blocks, T3169 will be started. When T3169 overflows, the network will release the TBF. and the TBF will be released.. Signless integer. 94) N3105: when the network sends a RRBP domain in the downli nk RLC data block, if effective RLC/MAC control messages from MS have not been received for N3105 times, the downlink TBF will be released internally and T3195 will be started. Signless integer. 95) T3169: the timer for the network to reuse the TFI and USF resources. Signless integer. 96) T3191: the timer for the network to release TBF. Signless integer.

97) T3193: the protection timer for releasing TBF in the packet downlink transmission process. Signless integer. 98) T3195: the protection time of TBF when there is no response from MS due to radio link failure or cell change. Signless integer. 99) BSSGPT1: 1s~30s, BSSGP-layer parameter, controlling the Block/Unblock process. Signless integer. 100) BSSGPT2: 1s~120s, BSSGP-layer parameter, controlling the Reset process. Signless integer. 101) BSSGPT3: 0.1s~10s, BSSGP-layer parameter, controlling the Suspend process. Signless integer.

Page 152 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

102) BSSGPT4: 0.1s~10s, BSSGP-layer parameter, controlling the Resume process. Signless integer. 103) BSSGPT5: 0.1s~10s, BSSGP-layer parameter, controlling the RA_CAPABILITY_UPDAT. Signless integer. 104) NS_T1: 1s~120s, NS link-layer parameter, controlling the blocking/unblocking process. Signless integer. 105) NS_T2: 1s~120s, NS link-layer parameter, controlling the reset process. Signless integer. 106) NS_T3: 1s~60s, NS link-layer parameter, controlling the periodic test process of NSVC. Signless integer. 107) NS_T4: 3s, NS link-layer parameter, controlling the alive process. Signless integer. 108) NS_T5: the maximum attempt period of Reset. Signless integer.

109) ccmT1: the protection timer for changing the type of FUC channel. Value range: 2~10s, the default is 10s. 110) ccmT2: the protection timer for T net connection. Value range: 2~10s, the default is 10s. 111) ccmT3: the protection timer for LSP moving . Value range: 2~10s, the default is 10s. 112) csMode: channel coding mode. Value range: 0 (the default coding mode is CS-2, but it can change between CS-2 and CS-1 dynamically), 1 (CS-1), 2 (CS-2), 3 (CS-3), 4 (CS-4). The default is 1. 1.5.1.10 RBCD 1. Command function To delete a radio BSC.
Page 153 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure RBCD: {BSCID, BSCNAME}; 3. Parameter description 1) BSCID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) BSCNAME (BSC Name): BSC identification name. Character string type, the maximum length is 40. 1.5.1.11 RBCM 1. Command function To modify a functional BSC. 2. Syntax structure RBCM: {BSCID, BSCNAME}: BARANG, MODIMODE [, ALIAS] [, MCC] [, MNC] [, NTERHO] [, t1] [, t3] [, t4] [, t7] [, t8] [, t10] [, t13] [, t17] [, t18] [, t19] [, t20] [, t9104] [, t9105] [, t9108] [, t9113] [, ZXGT1] [, ZXGT2] [, ZXGT3] [, ZXGT4] [, ZXGT5] [, ZXGT6] [, ZXGT7] [, ZXGT8] [, ZXGT9] [, ZXGT10] [, ZXGT11] [, RMSTQHO] [, ZXGT12] [, ZXGT13] [, ZXGT14] [, ZXGT15] [, ZXGT16] [, ZXGMT7] [, ZXGMT11] [, ZXGMT12] [, tMICRO] [, tBSIC ] [, AIST1] [, AIST4] [, AIST8] [, AIST12] [, BCRT] [, BCPT, ] [ T3101] [, t3103] [, t3107] [, t3109] [, t3111] [, t3113] [, BMRN] [, CMRN] [, CONFUMSG] [, RINDTHS] [, LOADIND] [, LVT] [, LIP] [, EDRAF] [, ACE] [, LOCNAME]: [CELFCTHS] [, MSFCTHS] [, CELFCPER] [, MSFCPER] [, DELAY] [, NSBLKMX] [, NSUNBLKM] [, NSALIVEM] [, BVCBLKM] [, BVCUBLKM] [, BVCRESTM] [, SUSPENDM] [, RESUMEM] [, UPDATEM] [, FLRPTPRD] [, CN] [, XN] [, NN] [, OVERLDTH] [, DEFRATE] [, N3101] [, N3103] [, N3105: T3169] [, t3191] [, t3193] [, t3195] [, BSSGPT1] [, BSSGPT2] [, BSSGPT3] [, BSSGPT4] [, BSSGPT5] [, NS_T1] [, NS_T2] [, NS_T3] [, NS_T4] [, NS_T5]; 3. Parameter description
Page 154 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSCID (Bss Function Identification): BSS identification number. Signless integer, value range1~255. 2) BSCNAME (BSC Name): BSC identification name. Character string type, the maximum length is 40. 3) BARANG (BA Range): broadcast range. Signless integer, value range: 1~124, 0, 512 to 885, 975 to 1023. 4) MODIMODE (Modify Mode): modification mode of broadcast range. Signless integer, value range: 0~2. (0: reset; 1: add; 2: delete ) 5) ALIAS: alias. Character string type, the maximum length is 40. 6) MCC (Mobile Country Code): Mobile country code. Signless integer, value range: 0~999. 7) MNC (Mobile NetWork Code): mobile network code. Signless integer, value range: 0~99. 8) INTERHO (Internal HandOver): whether to allow inter-cell handover. Type Boolean. 9) T1 (Timer1): blocking/unblocking period. Signless integer, value range: 30~150. 10) T3 (Timer3): protection time of instantaneous disconnection. Signless integer, value range: 10~200. 11) T4 (Timer4): global reset period. Signless integer, value range: 60~150. 12) T7 (Timer7): protection period of handover request. Signless integer, value range: 100~200. 13) T8 (Timer8): execution period of source BSC handover. Signless integer, value range: 80~150.

Page 155 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

14) T10 (Timer10): assignment period. Signless integer, value range: 40~140. 15) T13 (Timer13): protection period of global reset. Signless integer, value range: 30~60. 16) T17 (Timer17): the first overload period of flow control. Signless integer, value range: 10~100. 17) T18 (Timer18): the second overload period of flow control. Signless integer, value range: 30~200. 18) T19 (Timer19): reset period of the circuit at the BSS side. Signless integer, value range: 30~150. 19) T20 (Timer20): blocking /unblocking period of circuit group. Signless integer, value range: 30~150. 20) T9104 (Timer9104): monitoring the CLEAR command sent from MSC. Signless integer, value range: 20~50. 21) T9105 (Time9105): monitoring the SCCP connection process. Signless integer, value range: 20~60, the default value is 30. 22) T9108 (Time9108): monitoring the physical context request process. Signless integer, value range: 20, the default value is 20. 23) T9113 (Time9113): monitoring the external handover process in the target cell. Signless integer, value range: 50~180, the default value is 110. 24) ZXGT1 (ZX Gsm Timer1): the protection time for waiting for the access of MS after the channel is activated during assignment or handover. Signless integer, value range: 50~120, the default value is 70. 25) ZXGT2 (ZX Gsm Timer2): protection time of channel application. Signless integer, value range: 20~50, the default value is 40.

Page 156 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

26) ZXGT3 (ZX Gsm Timer3): the protection time for waiting for the link establishment response of the central module during immediate assignment. Signless integer, value range: 30~100, the default value is 60. 27) ZXGT4 (ZX Gsm Timer4): monitoring the modification process of MS channel mode. Signless integer, value range: 10~80, the default value is 30. 28) ZXGT5 (ZX Gsm Timer5): monitoring the modification process of encryption mode. Signless integer, value range: 30~120, the default value is 100. 29) ZXGT6 (ZX Gsm Timer6): monitoring the link establishment of SAPI3. Signless integer, value range: 10~300, the default value is 100. 30) ZXGT7 (ZX Gsm Timer7): the protection time for waiting for the response of P0 to assignment or the handover completion message. Signless integer, value range: 50~200, the default value is 150. 31) ZXGT8 (ZX Gsm Timer8): the time from the handover command to the clear command during outgoing handover. Signless integer, value range: 50~650, the default value is 100. 32) ZXGT9 (ZX Gsm Timer9): the protection time from the handover command to the clear command during outgoing handover. Signless integer, value range: 10~50, the default value is 20. 33) ZXGT10 (ZX Gsm Timer10): the queuing protection time for channel application.. Signless integer, value range: 50~200, the default value is 130. 34) ZXGT11 (ZX Gsm Timer11): the maximum allowed queuing time for assignment attempt. Signless integer, value range: 10~150, the default value is 60. 35) RMSTQHO (Retry Ms Timer Queue HandOver): the maximum allowed queuing time for handover attempt. Signless integer, value range: 10~150, the default value is 50.
Page 157 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

36) ZXGT12 (ZX Gsm Timer12): periodic status acknowledgement interval. Signless integer, value range: 100~18000, the default value is 3000. 37) ZXGT13 (ZX Gsm Timer13): monitoring the modification process of BTS and MS modes. Signless integer, value range: 35 to 100, the default value is 60. 38) ZXGT14 (ZX Gsm Timer14): the period of time from the moment when the target instance sends an assignment/handover command to the moment when the acknowledgement is received. Signless integer, value range: 10~50, the default value is 20. 39) ZXGT15 (ZX Gsm Timer15): the time taken for the target instance to wait for the availability of resources during forced release.. Signless integer, value range: 10~50, the default value is 30. 40) ZXGT16 (ZX Gsm Timer16): interval time of directional retry. Signless integer, value range: 20~60, the default value is 20. 41) ZXGMT7 (ZX Gsm MTimer7): protection time of external handover. Signless integer, value range: 1~65535, the default value is 100. 42) ZXGMT11 (ZX Gsm MTimer11): a clock in the overload control. Signless integer, value range: 50~200. 43) ZXGMT12 (ZX Gsm MTimer12): a clock in the overload control. Signless integer, value range: 100~300. 44) TMICRO (Timer Micro): time delay timer for micro-micro handover. Signless integer, value range: 50~200. 45) TBSIC (BISC Timer): BSIC decoding period. Signless integer, value range: 20~640. 46) AIST1 (AIS Timer1): Assigning status protection timer. Signless integer, value range: 40~150.

Page 158 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

47) AIST4 (AIS Timer4): RapidApplying status protection timer. Signless integer, value range: 30~150. 48) AIST8 (AIS Timer8): OutGoHoing status protection timer. Signless integer, value range: 50~700. 49) AIST12 (AIS Timer12): Serving status protection timer. Signless integer, value range: 100~18000. 50) BCRT (BCRT): routine timer for system message broadcast. Signless integer, value range: 6000~864000. 51) BCPT (BCPT): protection timer of system message broadcast for waiting for the response of FUC. Signless integer, value range: 30~100. 52) T3101 (Timer3101): the maximum period of time from the moment when the BSC network side sends an immediate assignment to the moment when the MS acquires a channel successfully. Signless integer, value range: 10~50. 53) T3103 (Timer3103): the maximum period of time from the moment when the BSC network side sends an handover to the moment when the MS acquires a channel successfully. Signless integer, value range: 35 to 100. 54) T3107 (Timer3107): the timer for managing assignment and intra-cell handover. Signless integer, value range: 35 to 100. 55) T3109 (Timer3109): the maximum time taken for completely releasing the channel when a low-layer error occurs or the channel release process begins. Signless integer, value range: 10~150. 56) T3111 (Timer3111): the time taken from releasing the traffic channel to deactivating the RF channel. Signless integer, value range: 1~5. 57) T3113 (Timer3113): time delay timer for micro-micro handover. Signless integer, value range: 0~65535.

Page 159 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

58) BMRN (BSC Max Retry Number): the maximum number of repetition times for BSC reset process . Signless integer, value range: 1~255. 59) CMRN (Circuit Max Retry Number): the maximum number of repetition times for circuit reset process . Signless integer, value range: 1~255. 60) CONFUMSG (Confusion Message): whether to allow BSC to send BSSAP Confusion message. Type Boolean. 61) RINDTHS (Resource Indication threshold): the threshold for BSC to spontaneously indicate resources (available channels) to MSC (%). Signless integer, value range: 0~100. 62) 63) LOADIND: Load Indication. Type Boolean. LVT: Load Valid Time. Signless integer, value range: 1~255.

64) LIP: Load Indication Period. Signless integer, value range: 10~65530. 65) EDRAF (EDRAF): whether to allow assignment failure for directional retry. Type Boolean. 66) ACE (ACE): whether to allow BSC to allocate the land circuit by itself. Type Boolean. 67) LOCNAME (Location Name): resource location information. Character string type, the maximum length is 40. 68) CELFCTHS: BSSGP flow control thresho ld of the cell. Signless integer, value range: (0~100). 69) MSFCTHS: BSSGP flow control threshold of the MS. Signless integer, value range: (0~100). 70) CELFCPER: BSSGP flow control trigger period of the cell (unit: 10ms). Signless integer.
Page 160 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

71) MSFCPER: BSSGP flow control trigger period of the MS (unit: 10ms). Signless integer. 72) DELAY: NS-VC end-to-end time delay (unit: 10ms). Signless integer. 73) NSBLKMX: the maximum number of retry times for Block of NS, NS link-layer parameter. Signless integer, the maximum length is 3. 74) NSUNBLKM: the maximum number of retry times for Unblock of NS, NS link-layer parameter. Signless integer, the maximum length is 3. 75) NSALIVEM: the maximum number of retry times for Alive of NS, NS link-layer parameter. Signless integer, the maximum length is 10. 76) BVCBLKM: the maximum number of retry times for Block of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 77) BVCUBLKM: the maximum number of retry times for Unblock of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 78) BVCRESTM: the maximum number of retry times for Reset of BVC, BSSGP-layer parameter. Signless integer, the maximum length is 3. 79) SUSPENDM: the maximum number of retry times for Suspend, BSSGP-layer parameter. Signless integer, the maximum length is 3. 80) RESUMEM: the maximum number of retry times for Resume, BSSGP-layer parameter. Signless integer, the maximum length is 3. 81) UPDATEM: the maximum number of retry times for RA_CAPABILITY_UPDATE_RETRIES, BSSGP-layer parameter. Signless integer, the maximum length is 3. 82) FLRPTPRD : reporting period of channel failure rate (unit: 52 multi-frames). Signless integer. 83) CN: When the accumulated number of continuously and correctly received data blocks exceeds the preset parameter CN, then the
Page 161 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

transmitting coding mode of MS will be improved by one level. Signless integer array, the number is 3. 84) XN: when Xn% data blocks have been lost in Nn continuous data blocks, the transmitting coding mode of MS will be reduced by one level.. Signless integer array, the number is 3. 85) NN: when Xn% data blocks have been lost in Nn continuous data blocks, the transmitting coding mode of MS will be reduced by one level.. Signless integer array, the number is 3. 86) OVERLDTH: maximum bearing ideal rate for PS channel (unit: 100b/s). Signless integer. 87) DEFRATE: default rate for initial access (unit: 100b/s). Signless integer. 88) N3101: when USF has been set on the network, if no effective data has been received for N3101 continuous blocks, the network will regard the TBF quality as being too poor, and the TBF will be released.. Signless integer. 89) N3103: if the network has not received the Packet Control Ack message for N3103 times in specified blocks, T3169 will be started. When T3169 overflows, the network will release the TBF. and the TBF will be released.. Signless integer. 90) N3105: when the network sends a RRBP domain in the downlink RLC data block, if effective RLC/MAC control messages from MS have not been received for N 3105 times, the downlink TBF will be released and T3195 will be started. Signless integer. 91) T3169: the timer for the network to reuse the TFI and USF resources. Signless integer. 92) T3191: the timer for the network to release TBF. Signless integer.

93) T3193: the protection timer for releasing TBF in the packet downlink transmission process. Signless integer.
Page 162 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

94) T3195: the protection time of TBF when there is no response from MS due to radio link failure or cell change. Signless integer. 95) BSSGPT1: 1s~30s, BSSGP-layer parameter, controlling the Block/Unblock process. Signless integer. 96) BSSGPT2: 1s~120s, BSSGP-layer parameter, controlling the Reset process. Signless integer. 97) BSSGPT3: 0.1s~10s, BSSGP-layer parameter, controlling the Suspend process. Signless integer. 98) BSSGPT4: 0.1s~10s, BSSGP-layer parameter, controlling the Resume process. Signless integer. 99) BSSGPT5: 0.1s~10s, BSSGP-layer parameter, controlling the RA_CAPABILITY_UPDATE process. Signless integer. 100) NS_T1: 1s~120s, NS link-layer parameter, controlling the blocking/unblocking process. Signless integer. 101) NS_T2: 1s~120s, NS link-layer parameter, controlling the reset process. Signless integer. 102) NS_T3: 1s~60s, NS link-layer parameter, controlling the periodic test process of NSVC. Signless integer. 103) NS_T4: 3s, NS link-layer parameter, controlling the alive process. Signless integer. 104) 1.5.1.12 RBCQ 1. Command function To view the radio parameters of a BSC object. NS_T5: the maximum attempt period of Reset. Signless integer.

Page 163 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure RBCQ: BSCID: PARAGRP; 3. Parameter description 1) BSCID (BSC Identification): BSC identification number. Signless integer, value range: 1~255. 2) PARAGRP (Parameter Group): parameter group to be queried. Enumerated type, value range: STATES, ALL, the default value is ALL. Among them, All refers to querying static attribute information, and STATES refers to querying dynamic attribute information. 1.5.1.13 RBTA 1. Command function To modify the status attribute of a cell 2. Syntax structure RBTA: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: AD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer type, value range1~255. 2) SITEID (Site Identification): site identification number. Signless integer type, value range1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): cell identification number. Signless integer type, value range1~3.

Page 164 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BTSNAME (BTS Name): cell identification name. Character string type, the length is 40. 6) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include L, U, S. L: locking state ; U: unlocking state; S: time delay blocking. 1.5.1.14 RBTC 1. Command function To add a new cell. 2. Syntax structure RBTC: BSSID {, SITEID, SITENAME}: BTSID, ALIAS, CELLTYPE: LAC, CI, NCC, BCC, GSMIND, BCCH, CA, CRH, NY1, PRDCLI, PLMNPMT, RBUSYTHS, RLAS, BRLTO, MRLTO, RXLAMIN: RETRANS, MSTXPMC, BAG, MULFRMPG, NSST: IMSIAD, BARRED, CBQ, CRA, DTXDL, ECR, NAAC, PRDUMS: T2SAPI0, t2TCHF, t2TCHH, t2TCHSA0, t2SDCCH, t2SAPI3, t2TCHSA3: HOMSMTMD: CCCHCFG: T3122, MBANDRPT, SCB, DTXULB, DTXULS: ACS, NECI, RSPI, CRO, tMPOFF, PENALTM, EPO, PWROFF, ECSC: DRIND, QUEIND0, QUEIND1, PREEMPI0, PREEMPI1, CANDINUM, CIPHER, FAIND1, FAIND2, FAIND3, FCIND1, FCIND2, FCIND3, FCIND4, OTPIND1, OTPIND2, OTPIND3, OTPIND5, OTPIND6, OTPIND7, ORLUL, ORLDL, CNTHSIND, RXLB, CIAIND, CIATHS, RESTHS: IFA, IFB0, IFB1, IFB2, IFB3, IFB4, IFB5: RLIT, PLIT, CFC, RXLTHS, RXQTHS, RXLQPRD, OLPRD, t3SDCCH, t3TCH, BAIND, CANBEXCH, CANSDDYN: LOCNAME: PSSUPPRT, ADDRSPI2, EXC_ACC, LSAOFFST, PRIO_THR, LSA_ID: NSEI, BVCI, RAC, SPCUMUNT, MNO, t3168, t3192, DRXTIMEM, BSCVMAX, CTRACKTP, ACCESSTP, PANDEC, PANINC, PANMAX, PCCREL, PBCHBLKS, PAGBLKRS, PRCHBLKS, tXINT, INSLTNUM, MRETRANS, PERSTLEV, ACCTRCLS, ALPHA, t_AVG_W, t_AVG_T, PB, PCMEASCH, PSI4SEND, N_AVG_I, RXLEVASN, MSTXMCCH, HCS_EXST, PRIOCLS, HCS_THR, RESELOFF, RESELHYS, C31_HYST, C32_QUAL, RADACRTY, t_RESEL, RARSLHYS, tMPOFFST, PNLTIME, SI3LOC, RACOLOR, MEAORDER, CTRORDER, NCNODRXP, NCREPPRI, NCREPPRT, EXMEAODR, EXTREPTP, EXTREPPR, SPGCSPRT, PRIACTHR,
Page 165 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

PSI1RPPR, PSISTIND, CSCHSTHS, OVLOADPR, PCCHIDTH, RLTIMOUT, BRPGROUP, BVCAD; 3. Parameter description

SENDSPD, EPAGEMOD, PRCHBSYT, MEAAGSLT,

1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITEAME (Site Name): site identification number. Character string type, value range: 1~40. 4) BTSID (BTS Identification): cell identification number. Signless integer, value range: 1~3. 5) ALIAS (alias): cell alias. Character string type, value range: 1~40. 6) CELTYPE (Cell Type): cell type. Signless integer, value range: 0~3, the default value is 1. 7) LAC (Location Code): location area code. Signless integer, value range: 1~65535, without including 65534. 8) CI (Cell Identification): cell identification code. Signless integer, value range: 0~65535. 9) NCC (Network Color Code): network color code. Signless integer, value range: 0~7. 10) BCC (Base station Color Code): base station color code. Signless integer, value range: 0~7. 11) GSMIND (Gsm Indication): frequency band indication. Signless integer, value range: 0~2, the default value is 0. Among them, : 0: GSM900; 1: EGSM900; 2: GSM1800.
Page 166 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

12) BCCH (Broadcast Channel): frequency of BCCH. Signless integer, (as the first element of CA), value range: 1~124, 0, 512 to 885, 975 to 1023. 13) CA: a collection of radio frequencies that can be used in the cell (without including the BCCH frequency). Signless integer, value range: 1~124, 0, 512 to 885, 975 to 1023, NULL. 14) CRH (Cell Reselection Hold): cell reselection lagging level. Signless integer, value range: 0~7, the default value is 4. 15) NY1: the maximum number of repetition times for sending Physical Information messages in a handover. Signless integer, value range: 5 to 35, the default value is 8. 16) PRDCLI: the period for notifying BSC of the CCCH indication message. Signless integer, value range: 1~255, the default value is 2. 17) PLMNPMT: allowing MS to report the PLMN table of the measured result. Signless integer, value range: 0~7. 18) RBUSYTHS (RACH Burst Threshold): the threshold of the received signal level in a RACH burst pulse period. Signless integer, value range: 0~63, the default value is 63. 19) RLAS: the average number of burst pulses measured at RACH. Signless integer, value range: 0~100, the default value is 60. 20) BRLTO: the maximum value of counter S for inspecting radio link faults at the BSS side. Signless integer, value range: 0~15, the default value is 15. 21) MRLTO: the maximum value of counter S for inspecting radio link faults at the MS side. Signless integer, value range: 0~15, the default value is 15. 22) RXLAMIN: the minimum received intensity level of MS when it visits this cell. Signless integer, value range: 0~63, the default value is 10.
Page 167 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

23) RETRANS: the maximum number of retransmission times of MS on RACH for an access. Signless integer, value range: 1, 2, 4, 7, the default value is 4. 24) MSTXPMC: the (maximum) power that can be used by MS when it accesses the system initially. Signless integer, value range: 0~31, the default value is 5. 25) BAG: the number of blocks used in AGCH in 51 multi-frames. Signless integer, value range: 0~7, the default value is 2. 26) MULFRMPG: the number of multi-frames of 51 TDM frames for transmitting paging messages to the MSs of the same paging group. Signless integer, value range: 2 to 9, the default value is 5. 27) NSST: the maximum time interval for retransmission of MS on RACH. Signless integer, value range: 0~15, the default value is 14. 28) IMSIAD: whether IMSI attach/detach is allowed for the cell. Type Boolean, the default value is T. 29) BARRED: whether the cell is barred. Type Boolean, the default value is F. 30) CBQ: cell barring restriction. Type Boolean, the default value is F.

31) CRA: whether MS call re-establishment is allowed in the cell. Type Boolean, the default value is T. 32) DTXDL: whether DTX mode is used in the downlink direction. Type Boolean, the default value is F. 33) ECR: whether all MS emergency calls are allowed or only type11-to-15 MS emergency calls are allowed. Type Boolean, the default value is F. 34) NAAC: MS category that is barred for accessing the cell. Signless integer, value range: 0~9, 11~15.
Page 168 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

35) PRDUMS: interval period for MS location updating (T3212). Signless integer, value range: 0~255, the default value is 10. 36) T2SAPI0: LAPDM timer used for controlling the SDCCH channel. Signless integer, value range: 1, the default value is 1. 37) T2TCHF: LAPDM timer used for controlling FACCH/full rate. Signless integer, value range: 1, the default value is 1. 38) T2TCHH: LAPDM timer used for controlling FACCH/half rate. Signless integer, value range: 1, the default value is 1. 39) T2TCHSA0: LAPDM timer used for controlling SACCH with TCH sapi0. Signless integer, value range: 2, the default value is 2. 40) T2SDCCH: LAPDM timer used for controlling SACCH with SDCCH. Signless integer, value range: 2, the default value is 2. 41) T2SAPI3: LAPDM timer used for controlling SDCCH sapi3. Signless integer, value range: 1, the default value is 1. 42) T2TCHSA3: LAPDM timer used for controlling SACCH with TCH sapi3. Signless integer, value range: 2, the default value is 2. 43) HOMSMTMD: whether to perform handover preprocessing and report period. Signless integer, value range: 0, 2, 3, 4, the default value is 4. Among them, : 0: disallow; 1: allow. 44) CCCHCFG: structural parameter of common control channel (CCCH). Signless integer, value range: 0, 1. 2, 4, 6, the default value is 0. 45) T3122: interval t ime for MS to make the next access attempt after an access request fails (in IMME ASSIGN REJ). Signless integer, value range: 0~255, the default value is 10. 46) MBANDRPT: the number of adjacent cells in adjacent frequency bands reported and measured by MS in multi-frequency band operation. Signless integer, value range: 0~3, the default value is 3.
Page 169 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

47) SCB: the mode for allowing the cell-broadcast short-message service in the cell. Signless integer, value range: 0~2, the default value is 0. 48) DTXULB: the mode for MS to use DTX (broadcast over BCCH). Signless integer, value range: 0~2, the default value is 2. 49) DTXULS: the mode for MS to use DTX (broadcast over SACCH). Signless integer, value range: 0~7, the default value is 5. 50) ACS: attached reselection parameter indication. Type Boolean, the default value is F. 51) NECI: whether the hardware capability supports half rate. Type Boolean, the default value is F. 52) RSPI: whether to use C2 reselection parameter indication of the cell. Type Boolean, the default value is F. 53) CRO: a correction value of the C2 reselection standard. Signless integer, value range: 0~63, the default value is 5. 54) TMPOFF: a negative correction value of the C2 reselection standard in the Penalty_Time period. Signless integer, value range: 0~7, the default value is 1. 55) PENALTM: action time of the Penalty_Time parameter (20s). Signless integer, value range: 0~31, the default value is 0. 56) EPO: indication of the POWER-OFFSET parameter. Type Boolean, the default value is F. 57) PWROFF: initial access power correction for the MS of type 3 DCS1800. Signless integer, value range: 0~3, the default value is 0. 58) ECSC: early category sending control. Type Boolean, the default value is T. Among them, : True: enable; False: disable.

Page 170 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

59) DRIND: whether to use Directed Retry. Type Boolean, the default value is F. 60) QUEIND0: whether queuing is allowed during assignment. Type Boolean, the default value is F. 61) QUEIND1: whether queuing is allowed during handover. Type Boolean, the default value is F. 62) PREEMPI0: forced release flag for assignment (occupancy, vulnerability).Type Boolean, the default value is F. 63) PREEMPI1: forced release flag for handover (occupancy, vulnerability).Type Boolean, the default value is F. 64) CANDINUM: the maximum number of candidate cells that may exist in the HANDORVD message. Signless integer, value range: 1~16, the default value is 6. 65) CIPHER: cipher mode supported by the cell. Signless integer, value range: 0~7, the default value is 1 (0 represents no cipher mode, and can not be input together with other values). 66) FAIND1: whether fast average is allowed after call establishment. Type Boolean, the default value is T. 67) FAIND2: whether fast average is allowed after handover. Type Boolean, the default value is T. 68) FAIND3: whether fast average is allowed after power control. Type Boolean, the default value is T. 69) FCIND1: whether FACCH call establishment is allowed for emergency call. Type Boolean, the default value is T. 70) FCIND2: whether FACCH call establishment is allowed for answering paging call. Type Boolean, the default value is T.

Page 171 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

71) FCIND3: whether FACCH call establishment is allowed for originating call. Type Boolean, the default value is T. 72) FCIND4: whether FACCH call establishment is allowed for call re-establishment. Type Boolean, the default value is T. 73) OTPIND1: whether the transmitting power is optimized during assignment in the uplink direction. Type Boolean, the default value is F. 74) OTPIND2: whether the transmitting power is optimized during intra-cell handover in the uplink direction. Type Boolean, the default value is F. 75) OTPIND3: whether the transmitting power is optimized during inter-cell handover in the uplink direction. Type Boolean, the default value is F. 76) OTPIND5: whether the transmitting power is optimized during assignment in the downlink direction. Type Boolean, the default value is F. 77) OTPIND6: whether the transmitting power is optimized during intra-cell handover in the downlink direction. Type Boolean, the default value is F. 78) OTPIND7: whether the transmitting power is optimized during inter-cell handover in the downlink direction. Type Boolean, the default value is F. 79) ORLUL: uplink optimal signal leve l. Signless integer, value range: 0~63, the default value is 22. 80) ORLDL: downlink optimal signal level. Signless integer, value range: 0~63, the default value is 22. 81) CNTHSIND: the minimum acceptable carrier-to-noise ratio during channel allocation. Signless integer, value range: 0~63, the default value is 15.

Page 172 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

82) RXLB: balancing degree of uplink and downlink signals . Signless integer, value range: 0~20, the default value is 0. 83) CIAIND: whether the assignment process of TCH from SDCCH to a special TRX can be executed. Type Boolean, the default value is F. 84) CIATHS: the minimum signal level allowed in the uplink direction during the execution of the TCH assignment process from SDCCH to a special TRX. Signless integer, value range: 0~63, the default value is 25. 85) RESTHS: the minimum resources threshold allowed for the cell (%). Signless integer, value range: 0~100, the default value is 100. 86) IFA: the number of interference-level SACCH multi-frames in the idle time slots for measurement, i.e., the measurement period (unit: 102 TDMA frames). Signless integer, value range: 1~31, the default value is 31. 87) IFB0: interference band boundary [0]. Signless integer, value range: 0, the default value is 0. 88) IFB1: interference band boundary [1]. Signless integer, value range: 0~63, the default value is 10. 89) IFB2: interference band boundary [2]. Signless integer, value range: 0~63, the default value is 15. 90) IFB3: interference band boundary [3]. Signless integer, value range: 0~63, the default value is 20. 91) IFB4: interference band boundary [4]. Signless integer, value range: 0~63, the default value is 25. 92) IFB5: interference band boundary [5]. Signless integer, value range: 63, the default value is 63. 93) RLIT: RACH load indication threshold . Signless integer, value range: 0~100, the default value is 60.

Page 173 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

94) PLIT: PCH load indication threshold. Signless integer, value range: 0~100, the default value is 60. 95) CFC: the criterion for judging the failure of a radio link at the network side (BTS). Signless integer, value range: 1~2, the default value is 1. 1: based on the correct decoding rate of the uplink SACCH; 2: based on the measured value of rxLev/rxqual. 96) RXLTHS: the received level threshold for checking radio link failure at the network side (BTS). Signless integer, value range: 0~63, the default value is 10. 97) RXQTHS: the receiving quality threshold for checking radio link failure at the network side (BTS). Signless integer, value range: 0~7, the default value is 6. 98) RXLQPRD: the period (unit: SACCH multiframe) for checking radio link failure at the network side (BTS). Signless integer, value range: 1~63, the default value is 63. 99) OLPRD: the minimum period for BTS to send the Overload message (unit: 102 TDMA frames). Signless integer, value range: 1~255, the default value is 2. 100) T3SDCCH: the interval time for the repetition of PHY INFO messages in the course of SDCCH channel handover. Signless integer, value range: 1~67, the default value is 28. 101) T3TCH: the interval time for the repetition of PHY INFO messages in the course of TCH channel handover. Signless integer, value range: 1~32, the default value is 10. 102) BAIND: BA indication. Signless integer, value range: 0, 1. the default value is 1. 103) CANBEXCH: allowing BCCH changeover. Type Boolean, the default value is F.

Page 174 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

104) CANSDDYN: allowing SDCCH changeover. Type Boolean, the default value is F. 105) LOCNAME: resource location information. Character string type, the maximum length is 40. 106) NSEI: NSE identification of the cell. Signless integer.

107) BVCI: BVC identification number of the cell in NSE. Signless integer. 108) 109) 110) RAC: route area code. Signless integer. SPCUMUNT: SPCU multi-unit name. Signless integer. MNO: network operation mode in the cell. Signless integer.

111) T3168 : the maximum time for MS to wait for the Packet Uplink Assignment message after sending the Packet Resource request message. Signless integer. 112) T3192: the time length for MS to wait for the releasing of TBF and start to intercept the paging channel after receiving the last data block. Signless integer. 113) DRXTIMEM: the time length ( DRX_TIMER_MAX) after the MS switches over to the packet idle mode from the packet transmission mode and gets into the non-DRX mode. Signless integer. 114) BSCVMAX: the maximum number of blocks (BS_CV_MAX) allowed for sending over various time slots. Signless integer. 115) CTRACKTP: packet control (CONTROL_ACK_TYPE). Signless integer. acknowledgement type

116) ACCESSTP: the bit type that should be used in access burst ACCESS_BURST_TYP. Signless integer.

Page 175 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

117) PANDEC: decreasing step length of counter N3102. Signless integer. 118) PANINC: increasing step length of counter N3102. Signless integer. 119) PANMAX: maximum value of counter N3102. Signless integer.

120) PCCREL: whether PDCH channel is released immediately (BS_PCC_REL). Type Boolean. 121) PBCHBLKS: the number of blocks allocated to PBCCH in multiframes (BS_PBCCH_BLK). Signless integer. 122) PAGBLKRS: the number of reserved blocks for access permission in packet services (BS_PAG_BLKS_RES). Signless integer. 123) PRCHBLKS: the number of fixed blocks allocated to PRACH on PCCCH (BS_PRACH_BLK). Signless integer. 124) TXINT: the number of time slots for random access transmission (TX_INT). Signless integer. 125) INSLTNUM: the minimum time slot for calculating the interval of two continuous channel requests. Signless integer. 126) MRETRANS: the maximum number of retransmission times for various radio priority levels (MAX_RETRANS ). Signless integer array, with 4 elements. 127) PERSTLEV: access persistence level of various radio priority levels (PERSISTENCE_LEVE). Signless integer array, with 4 elements. 128) ACCTRCLS: access permission for the MS of the corresponding access control level (ACC_CONTR_CLAS). Signless integer array, with 6 elements. 129) ALPHA: parameter for MS transmitting power control. Signless integer.
Page 176 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

130) T_AVG_W: signal intensity filter period for power control in the packet idle mode. Signless integer. 131) T_AVG_T: signal intensity filter period for power control in the packet transmission mode. Signless integer. 132) PB: power decrement of PBCCH relative to BCCH. Signless integer. 133) PCMEASCH: measurement location for power control (indicating the position for measuring the downlink power intensity for the purpose of uplink power control by MS). Signless integer. 134) PSI4SEND: whether PSI4 is transmitted (i.e., whether the interference measurement channel list is included) (INT_MEAS_CHANNEL_LIST_AVAIL ). Type Boolean. 135) N_AVG_I: constant for filtering the interference signal intensity. Signless integer. 136) RXLEVASN: the minimum received level for allowing MS to access the GPRS system (GPRS_RXLEV_ACCESS_MIN). Signless integer. 137) MSTXMCCH: the maximum power used by MS before receiving the network power control information (GPRS_TXPWR_MAX_CCH). Signless integer. 138) HCS_EXIST: whether the HSC (hierarchical cell) parameter exists in the cell. Type Boolean. 139) PRIOCLS: the HCS priority level of the cell (PRIORITY_CLAS). Signless integer. 140) HCS_THR: the HCS signal intensity threshold of the cell. Signless integer. 141) RESELOFF: cell reselection (GPRS_RESELECT_OFFSET). Signless integer. offset
Page 177 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

142) RESELHYS: cell reselection (GPRS_CELL_RESELECT _HYSTERESI). Signless integer.

hysteresis

143) C31_HYST: whether the cell reselection hysteresis parameter acts on the C31 standard. Type Boolean. 144) C32_QUAL: whether exception is employed when using GPRS_RESELECT_OFFSET. Type Boolean. 145) RADACRTY: whether MS is allowed to attempt to access another cell (RANDOM_ACCESS_RETRY). Type Boolean. 146) T_RESEL: the minimum interval reselected to this cell. Signless integer. 147) RARSLHYS: route area reselection (RA_RESELECT_HYSTERESIS ). Signless integer. hysteresis

148) TMPOFFST: temporary offset for GPRS cell reselection (GPRS_TEMPORY_OFFSET). Signless integer. 149) PNLTIME: penalty time for (GPRS_PENALTY_TIME). Signless integer. GPRS cell reselection

150) SI3LOC : sending position of SI3 on BCCH (0: BCCH Norm; 1: BCCH Ext). Signless integer. 151) RACOLOR: if a MS finds that the RACOLOR of the cell is different, then the reselection information of the cell is regarded as different route areas.. Signless integer. 152) MEAORDER: the measurement report command of the MS in the cell (MEASUREMENT_ORDER). Type Boolean. (0: MS controls cell reselection and no measurement report will be sent to the network; 1: MS must send the measurement report to the network for cell reselection). 153) CTRORDER: network control command used in the cell (NETWORK_CONTROL_ORDER). Signless integer.
Page 178 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

154) NCNODRXP: the minimum period when the MS should stay in the non-DRX mode after sending a NC measurement report (NC_NON_DRX_PERIOD). Signless integer. 155) NCREPPRI: measurement report period of cell reselection in the packet idle mode of the MS (NC_REPORTING_PERIOD_I). Signless integer. 156) NCREPPRT: measurement report period of cell reselection in the packet transmission mode of the MS (NC_REPORTING_PERIOD_T). Signless integer. 157) EXMEAODR: extended measurement (EXT_MEASUREMENT_ORDE). Signless integer. order

158) EXTREPTP: extended measurement reporting type of the MS (EXT_REPORTING_TYPE). Signless integer. 159) EXTREPPR: time interval of the extended measurement report (EXT_REPORTING_PERIOD). Signless integer. 160) SPGCSPRT: whether SPLIT_PG_CYCLE is supported on CCCH of the cell (SPGC_CCCH_SUP).Type Boolean. 161) PRIACTHR: priority level for allowing (PRIORITY_ACCESS_THR). Signless integer. 162) PSI1RPPR: repetition period (PSI1_REPEAT_PERIO). Signless integer. of packet access

PSI1

messages

163) PSISTIND: indicating whether the network supports PACKET PSI STATUS messages. Signless integer. 164) CSCHSTHS : the threshold for the number of idle channels in the CS state when the PS+CS channel converts to the PS channel. Signless integer.

Page 179 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

165) SENDSPD: whether various types of system messages need to be sent at high rates (0: PSI2; 1: PSI3; 2: PSI3BIS; 3: PSI4; 4: PSI5; 5: PSI13).Type Boolean array, with 6 elements. 166) EPAGEMOD: whether the cell supports extended paging mode. Type Boolean. 167) LoadPer: load calculation period of PPCH channel (S). Signless integer. 168) OVLOADPR: PRACH overload report period (S). Signless integer. 169) PCCHIDTH: overload threshold. Signless integer array type, with 3 elements. (0: PRACH overload threshold proportion; 1: average queue length threshold in 64 multi-frame paging period; 2: threshold for the number of buffered paging channel messages) (%) 170) RLTIMOUT: initial value of the GPRS link failure counter. Signless integer. 171) PRCHBSYT: PRACH overload level threshold. Signless integer.

172) MEAAGSLT: average number of bursts for PRACH load measurement. Signless integer. 173) PSSUPPRT: whether GPRS is supported. Type Boolean.

174) ADDRSPI2: whether SYS16 and SYS17 are allowed to be sent over BCCH. Type Boolean. 175) EXC_ACC: whether the MS with SoLSA dedicated access right is allowed for access. Type Boolean. 176) LSA_OFFSET: the offset between the cells with the same LSA priority during LSA cell reselection. Signless integer. 177) PRIO_THR: the signal intensity threshold of MS when priority reason is used for cell reselection. Signless integer.
Page 180 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

178) LSA_ID: LSA identification (the lowest 24 bits are effective ). Signless integer. 1.5.1.15 RBTD 1. Command function To delete a cell. 2. Syntax structure RBTD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer type, value range1~255. 2) SITEID (Site Identification): site identification number. Signless integer type, value range1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the length is 40. 4) BTSID (BTS Identification): cell identification number. Signless integer type, value range1~3. 5) BTSNAME (BTS Name): cell identification name. Character string type, the length is 40. 1.5.1.16 RBTI 1. Command function To view the status attribute of BVC. 2. Syntax structure

Page 181 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RBTI: {BSSID, BSSNAME}, SITEID, BTSID: NSEI, BVCI; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) BSSNAME (BSS Name): BSS name. Character string type, the maximum length of the character string is 40. 3) SITEID (SITE Identification): SITE identification number. Signless integer, value range: 1~1024. 4) BTSID (BTS Identification): BTS identification number. Signless integer, value range: 1~3. 5) NSEI ( NSE Identification): NSE identification number. Signless integer, value range: 0~65535. 6) BVCI (BVC Identification): BVC identification number. Signless integer, value range: 0~65535. 1.5.1.17 RBTM 1. Command function To modify the status attribute of BVC. 2. Syntax structure RBTM: {BSSID, BSSNAME}, SITEID, BTSID: BVCAD; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255.

Page 182 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) BSSNAME (BSS Name): BSS name. Character string type, maximum length of the character stri ng is 40.

The

3) SITEID ( SITE Identification): SITE identification number. Signless integer, the default value is 1. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BVCAD ( BVCAD): Signless integer, value range: 0~1. 1.5.1.18 RBTQ 1. Command function To view the parameters of a cell. 2. Syntax structure RBTQ: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME}: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40.

Page 183 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PARAGRP (Parameter Group): radio parameter attribute package type. Enumerated type, value range: STATES, ALL, the default value is ALL. Among them, All refers to querying static attribute information, and STATES refers to querying dynamic attribute information. 1.5.1.19 RBTR 1. Command function To reset BVC. (including signaling reset) 2. Syntax structure RBTR: {BSSID, BSSNAME}, SITEID, BTSID : NSEI, BVCI; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) BSSNAME (BSS Name): BSS name. Character string type, the maximum length of the character string is 40. 3) SITEID (SITE Identification): SITE identification number. Signless integer, the default value is 1. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) NSEI ( NSEI): NSE number. Signless integer, value range: 0~20. 6) BVCI (BVCI): BVC number. Signless integer, value range: 1~4. 1.5.1.20 RCHA 1. Command function To modify the administration state attribute of a radio channel object.
Page 184 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure RCHA: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: AD; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) CHID (Channel Identification): channel identification number. Signless integer, value range: 0~7. 8) AD (Administer State): administration state attribute .. Enumerated type, the enumerated items include: L, U, S. L: locking state; U: unlocking state; S: time delay blocking. 1.5.1.21 RCHC 1. Command function To add a new radio channel object.

Page 185 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure Format 1: control channel (without frequency hopping ) RCHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID: CHID: CHCOMB, ARFCN: TSC; Format 2: non-BCCH control channel (with frequency hopping) RCHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID: CHID: CHCOMB, FHSID, MAIO, tSC; Format 3: traffic channel (without frequency hopping ) RCHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID: CHID: CHCOMB, ARFCN: PCMNO, PCMTS, PCMSUBTS: TSC: CHNGABLE; Format 4: traffic channel (with frequency hopping) RCHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID: CHID: CHCOMB, FHSID, MAIO, tSC: CHNGABLE; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40.
Page 186 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) CHID (Channel Identification): channel identification number. Signless integer, value range: 0~7. 8) CHCOMB (Channel Combination): Signless integer, value range: 3 to 8. channel combination mode.

9) ARFCN: Absolute RF Channel No. Signless integer, value range: 0~124, 512 to 885, 975 to 1023. 10) 0~7. TSC: Training Sequence Code. Signless integer, value range:

11) MAIO: Mobile Allocation Index Offset. Signless integer, value range: 0~63. 12) FHSID: Frequency Hopping System Identification. Signless integer, value range: 1~255. 13) PCMNO: PCM Circuit No. Signless integer, value range: 1~360.

14) PCMTS (Pcm Circuit Time Slot): time slot number of PCM circuit. Signless integer, value range: 0~31. 15) PCMSUBTS (Pcm Circuit Sub Time Slot): sub-time-slot number of PCM circuit. Signless integer, value range: 0~3. 16) CHNGABLE: whether the time slot is adjustable between PS and CS. Type Boolean. 1.5.1.22 RCHD 1. Command function To delete a radio channel object.

Page 187 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure RCHD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) CHID (Channel Identification): channel identification number. Signless integer, value range: 0~7. 1.5.1.23 RCHM 1. Command function To modify a radio channel object. 2. Syntax structure Format 1: control channel (without frequency hopping )

Page 188 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RCHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: CHCOMB, ARFCN, tSC; Format 2: non-BCCH control channel (with frequency hopping) RCHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: CHCOMB, FHSID, MAIO, tSC; Format 3: traffic channel (without frequency hopping) RCHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: CHCOMB, ARFCN: PCMNO, PCMTS, PCMSUBS, tSC: CHNGABLE; Format 4: traffic channel (with frequency hopping) RCHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: CHCOMB, MAIO, FHSID, PCMNO, PCMTS, PCMSUBS, tSC: CHNGABLE; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Id entification): transceiver identification number. Signless integer, value range: 1~36.
Page 189 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) CHID (Channel Identification): channel identification number. Signless integer, value range: 0~7. 8) CHCOMB (Channel Combination): Signless integer, value range: 3 to 8. channel combination mode.

9) ARFCN: Absolute RF Channel No. Signless integer, value range: 0~124, 512 to 885, 975 to 1023. 10) 0~7. TSC: Training Sequence Code. Signless integer, value range:

11) MAIO: Mobile Allocation Index Offset. Signless integer, value range: 0~63. 12) FHSID: Frequency Hopping System Identification. Signless integer, value range: 1~255. 13) PCMNO: PCM Circuit No. Signless integer, value range: 1~360.

14) PCMTS (Pcm Circuit Time Slot): time slot number of PCM circuit. Signless integer, value range: 0~31. 15) PCMSUBTS (Pcm Circuit Sub Time Slot): sub-time-slot number of PCM circuit. Signless integer, value range: 0~3. 16) CHNGABLE: whether the time slot is adjustable between PS and CS. Type Boolean. 1.5.1.24 RCHQ 1. Command function To query a radio channel object. 2. Syntax structure

Page 190 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RCHQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID, CHID: PARAGRP; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) CHID (Channel Identification): channel identification number. Signless integer, value range: 0~7. 8) PARAGRP (Parameter Group): radio parameter attribute package type. Enumerated type, value range: STATES, ALL, the default value is ALL. Among them, ALL is for querying static attribute information; STATES is for querying dynamic attribute information. 1.5.1.25 RECC 1. Command function To add a new external cell. 2. Syntax structure
Page 191 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RECC: BSSID: ECID: BARFCN, MCC, MNC, LAC, CI, NCC, BCC: HOMARGIN, HMRL, HMRQ, ALIS: PSSUPPORT, EXC_ACC, LSA_ID, RAC, CELBRAC2, RXLEVASN, MSTXMCCH, RESELOFF, tMPOFFS, PNLTIME, HCS_EXST, HCS_THR, PRIOCLS; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) ECID (External Cell Identification): external cell identification number. Signless integer, value range: 1~65535. 3) BARFCN (Broadcast Absolute Radio Frequency Channel Number): absolute radio frequency channel number of BCCH. Signless integer, value range: 0~124, 512 to 885, 975 to 1023. 4) MCC (Mobile Country Code): Mobile country code. Signless integer, value range: 0~999, the default value is 460. 5) MNC (Mobile Network Code): mobile network code. Signless integer, value range: 0~99, the default value is 0. 6) LAC (Location): location area code. Signless integer, value range: 1~65535, excluding 65534. 7) CI (Cell Identification): cell identification code. Signless integer, value range: 0~65535. 8) NCC (Network Color Code): network color code. Signless integer, value range: 0~7. 9) BCC (Base station Color Code): base station color code. Signless integer, value range: 0~7. 10) HOMARGIN (Handover MARGIN): the minimum PBGT threshold required for MS to handover to this cell. Signless integer, value range: 0~48, the default is 30.
Page 192 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) HMRL (Handover Min Require Level): the minimum threshold required for MS to handover to this cell due to intensity. Signless integer, value range: 0~48, the default is 24. 12) HMRQ (Handover Min Require Quality): the minimum threshold required for MS to handover to this cell due to quality. Signless integer, value range: 0~48, the default is 22. 13) is 40. 14) ALIAS (Alias): alias. Character string type, the maximum length

PSSUPPORT: whether GPRS is supported. Type Boolean.

15) EXC_ACC: whether the MS with SoLSA dedicated access right is allowed for access. Type Boolean. 16) LSA_ID : LSA identification (the lowest 24 bits are effective ). Signless integer. 17) RAC: RA_CODE. Signless integer.

18) CELBRAC2: cell reselection status CELL_BAR_ACCESS_2. Type Boolean. 19) RXLEVASN: the minimum receiving level for allowing MS to access the GPRS system. Signless integer. 20) MSTXMCCH: the maximum power used by MS before receiving the network power control information. Signless integer. 21) RESELOFF: cell reselection offset. Signless integer.

22) TMPOFFS: temporary offset for cell reselection . Signless integer. 23) PNLTIME: penalty time for cell reselection . Signless integer.

Page 193 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

24) HCS_EXIST: whether the HSC parameter exists in the cell. Type Boolean. 25) HCS_THR: HCS signal intensity threshold of the cell. Type Boolean. 26) 1.5.1.26 RECD 1. Command function To delete an external cell. 2. Syntax structure RECD: BSSID, ECID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) ECID (External Cell Identification): external cell identification number. Signless integer. 1.5.1.27 RECM 1. Command function To modify the radio parameters of an external cell. 2. Syntax structure RECM: BSSID, ECID: [BARFCN] [, MCC] [, MNC] [, LAC] [, CI] [, NCC] [, BCC] [, HOMARGIN] [, HMRL] [, HMRQ] [, ALIAS], [PSSUPPORT ] [, EXC_ACC ] [, LSA_ID ] [, RAC ] [, CELBRAC2 ] [, RXLEVASN ] [, PRIOCLS: HCS priority of the cell. Signless integer.

Page 194 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

MSTXMCCH ] [, RESELOFF] [, tMPOFFS ] [, PNLTIME ] [, HCS_EXST ] [, HCS_THR ] [, PRIOCLS]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) ECID (External Cell Identification): external cell identification number. Signless integer, value range: 1~65535. 3) BARFCN (Broadcast Absolute Radio Frequency Channel Number): absolute radio frequency channel number of BCCH. Signless integer, value range: 0~124, 512 to 885, 975 to 1023. 4) MCC (Mobile Country Code): Mobile country code. Signless integer, value range: 0~999, the default value is 460. 5) MNC (Mobile Network Code): mobile network code. Signless integer, value range: 0~99, the default value is 0. 6) LAC (Location): location area code. Signless integer, value range: 1~65535, excluding 65534. 7) CI (Cell Identification): cell identification code. Signless integer, value range: 0~65535. 8) NCC (Network Color Code): network color code. Signless integer, value range: 0~7. 9) BCC (Base station Color Code): base station color code. Signless integer, value range: 0~7. 10) HOMARGIN (Handover MARGIN): the minimum PBGT threshold required for MS to handover to this cell. Signless integer, value range: 0~48, the default is 30.

Page 195 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) HMRL (Handover Min Require Level): the minimum threshold required for MS to handover to this cell due to intensity. Signless integer, value range: 0~48, the default is 24. 12) HMRQ (Handover Min Require Quality): the minimum threshold required for MS to handover to this cell due to quality. Signless integer, value range: 0~48, the default is 22. 13) is 40. 14) ALIAS (Alias): alias. Character string type, the maximum length

PSSUPPORT: whether GPRS is supported. Type Boolean.

15) EXC_ACC: whether the MS with SoLSA dedicated access right is allowed for access. Type Boolean. 16) LSA_ID : LSA identification (the lowest 24 bits are effective ). Signless integer. 17) RAC: RA_CODE. Signless integer.

18) CELBRAC2: cell reselection status CELL_BAR_ACCESS_2. Type Boolean. 19) RXLEVASN: the minimum receiving level for allowing MS to access the GPRS system. Signless integer. 20) MSTXMCCH: the maximum power used by MS before receiving the network power control information. Signless integer. 21) RESELOFF: cell reselection offset. Signless integer.

22) TMPOFFS: temporary offset for cell reselection . Signless integer. 23) PNLTIME: penalty time for cell reselection . Signless integer.

Page 196 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

24) HCS_EXIST: whether the HSC parameter exists in the cell. Type Boolean. 25) HCS_THR: HCS signal intensity threshold of the cell. Type Boolean. 26) 1.5.1.28 RECQ 1. Command function To view the radio parameters of an external cell. 2. Syntax structure RECQ: BSSID, ECID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) ECID (External Cell Identification): external cell identification number. Signless integer. 3) PARAGRP (PARAGE Radio Parameter): radio parameter attribute package type. Enumerated type, value range: ALL, the default value is ALL. 1.5.1.29 RFHC 1. Command function To add a new frequency hopping system object. 2. Syntax structure PRIOCLS: HCS priority of the cell. Signless integer.

Page 197 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RFHC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: F HSID: HSN, MA, FHMODE; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) FHSID (Frequency Hopping System Identification): frequency hopping system identification number. Signless integer, value range: 1~255. 7) HSN (Hopping Sequence Number): frequency hopping sequence number. Signless integer, value range: 0~63. 8) MA (Mobile Allocation): frequency set used by the hopping system. Composite signless integer, value range: [1..124] [, 0] [, 512..885] [, 975..1023]. 9) FHMODE (Frequency Hopping Mode): frequency hopping mode. Signless integer, value range: 1~2. Among them, 1 is for baseband frequency hopping, 1 is for radio frequency hopping. 1.5.1.30 RFHD 1. Command function

Page 198 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To delete a frequency hopping system object. 2. Syntax structure RFHD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, FHSID; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) FHSID (Frequency Hopping System Identification): frequency hopping system identification number. Signless integer, value range: 1~255. 1.5.1.31 RFHM 1. Command function To modify a frequency hopping system object. 2. Syntax structure RFHM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, FHSID: HSN, MA, FHMODE; 3. Parameter description
Page 199 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) FHSID (Frequency Hopping System Identification): frequency hopping system identification number. Signless integer, value range: 1~255. 7) HSN (Hopping Sequence Number): frequency hopping sequence number. Signless integer, value range: 0~63. 8) MA (Mobile Allocation): frequency set used by the hopping system. Composite signless integer, value range: [1..124] [, 0] [, 512..885] [, 975..1023]. 9) FHMODE (Frequency Hopping Mode): frequency hopping mode. Signless integer, value range: 1~2. Among them, 1 is for baseband frequency hopping, 1 is for radio frequency hopping. 1.5.1.32 RFHQ 1. Command function To query a frequency hopping system object 2. Syntax structure RFHQ: BSSID {, SITEID, S ITENAME} {, BTSID, BTSNAME}, FHSID;
Page 200 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) FHSID (Frequency Hopping System Identification): frequency hopping system identification number. Signless integer, value range: 1~255. 1.5.1.33 RHOC 1. Command function To add a new handover control functive . 2. Syntax structure RHOC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: HOID: CELLWND, CELLW, CHREQT: DISTWND, DHREQT: PBGTDEF, tPMDEF, RLMDEF: HULWND, HULW, HULHREQT: HDLWND, HDLW, HDLHREQT: HUQWND, HUQW, HUQHREQT: HDQWND, HDQW, HDQHREQT: HMRXL, HMRXQ, ZAHO, HOMARGIN, HOPRI, MSPWRMAX, RXLEVMIN, HINMIN: HULTHS, HULN, HULP: HDLTHS, HDLN, HDLP: HUQTHS, HUQN, HUQP: HDQTHS, HDQN, HDQP: INHULTHS, INHULN, INHULP: INHDLTHS, INHDLN, INHDLP: HOCTRL1, HOCTRL2, HOCTRL3, HOCTRL4, HOCTRL5, HOCTRL6, HOCTRL7, HOCTRL9, HOCTRL10, HOCTRL11, HOCTRL13, HOCTRL14, HOCTRL15, HOPIND1, HOPIND2, HOPIND3, HOPIND4, LYRPRI,
Page 201 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

LYRPBGT: RPDHOTHS, RPDHON: MAMITHS, MAMIN: GCITHS, GCIN, GCIP: BADCITHS, BADCIN, BADCIP: TIMEADV, DISTN, DISTP: PBGTHON, PBGTHOP: HFPT, DPRIOFF, PBGTOFF, tHLC, tHFC, tTHS; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer type, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HOID (Handover Identification): handover control Signless integer, value range: 1, the default value is 1. identification.

7) CELLWND (Cell Window): the parameter for calculating the measured mean by the adjacent cell in handover control. Signless integer, value range: 1~31, the default value is 2. 8) CELLW (Cell Weight): the weight for calculating the weighted mean by the adjacent cell in handover control. Signless integer, value range: 1~3, the default value is 1. 9) CHREQT (Cell HREQT): the reserved number for calculating the measured mean by the adjacent cell in handover control. Signless integer, value range: 1, the default value is 1. 10) DISTWND (Distance Window): the parameter for calculating the measured mean of distance in handover control. Signless integer, value range: 1~31, the default value is 2.
Page 202 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) DHREQT (Distance HREQT): the reserved number for calculating the measured mean of distance in handover control. Signless integer, value range: 1, the default value is 1. 12) PBGTDEF (PBGT Default): the minimum default PBGT threshold required for handing over to a undefined adjacent cell. Signless integer, value range: 0~24, the default value is 15. 13) TPMDEF (Transmit Power Ms Default): the maximum default transmitting power that can be used by MS in a undefined adjacent cell. Signless integer, value range: 0~24, the default value is 15. 14) RLMDEF (Receive Level Ms Default): the minimum default receiving intensity threshold required for handing over to a undefined adjacent cell. Signless integer, value range: 0~63, the default value is 15. 15) HULWND (Handover UpLink Window): the parameter for calculating the measured mean of uplink intensity in handover control. Signless integer, value range: 1~31, the default value is 2. 16) HULW (Handover Uplink Weight): the weight for calculating the weighted mean of uplink intensity in handover control. Signless integer, value range: 1~3, the default value is 2. 17) HULHREQT (Handover UpLink HREQT): the reserved number for calculating the weighted mean of uplink intensity in handover control. Signless integer, value range: 1, the default value is 1. 18) HDLWND (Handover DownLink Window): the parameter for calculating the measured mean of downlink intensity in handover control. Signless integer, value range: 1~31, the default value is 2. 19) HDLW (Handover DownLink Weight): the weight for calculating the weighted mean of downlink intensity in handover control. Signless integer, value range: 1~3, the default value is 2. 20) HDLHREQT (Handover DownLink HREQT): the reserved number for calculating the weighted mean of downlink intensity in handover control. Signless integer, value range: 1, the default value is 1.
Page 203 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

21) HUQWND (Handover UpLink Quality Window): the parameter for calculating the measured mean of uplink quality in handover control. Signless integer, value range: 1~31, the default value is 2. 22) HUQW (Handover Uplink Quality Window): the weight for calculating the weighted mean of uplink quality in handover control. Signless integer, value range: 1~3, the default value is 2. 23) HUQHREQT (Handover Uplink Quality HREQT): the reserved number for calculating the weighted mean of uplink quality in handover control. Signless integer, value range: 1, the default value is 1. 24) HDQWND (Handover Downlink Window): the parameter for calculating the measured mean of downlink quality in handover control. Signless integer, value range: 1~31, the default value is 2. 25) HDQW (Handover Downlink Quality Weight): the weight for calculating the weighted mean of downlink quality in handover control. Signless integer, value range: 1~3, the default value is 2. 26) HDQHREQT (Handover Downlink Quality HREQT): the reserved number for calculating the weighted mean of downlink quality in handover control. Signless integer, value range: 1, the default value is 1. 27) HMRXL (Handover Min Receive Level): the minimum threshold required for MS to handover to this cell due to intensity. Signless integer, value range: 0~48, the default value is 30. 28) HMRXQ (Handover Min Receive Quality): the minimum threshold required for MS to handover to this cell due to quality. Signless integer, value range: 0~48, the default value is 30. 29) ZAHO (Zero Accept Handover): the number of 0s that are allowed in the measured value in handover control. Signless integer, value range: 0~31, the default value is 1. 30) HOMARGIN (Handover MARGIN): the minimum PBGT threshold required for MS to hand over to this cell. Signless integer, value range: 0~48, the default value is 30.
Page 204 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

31) HOPRI (Handover Priority): static priority for cell handover (8 levels). Signless integer, value range: 0~7, the default value is 3. 32) MSPWRMAX (Ms Power Max): the maximum transmitting power that can be used by MS in adjacent cells. Signless integer, value range: 0~31, the default value is 5. 33) RXLEMIN (Receive Level Min): the minimum receiving intensity level for allowing MS to hand over to the cell. Signless integer, value range: 0~63, the default value is 15 34) HINMIN (Handover Interval Min): the minimum interval for continuous handover of cells. Signless integer, value range: 0~31, the default value is 5. 35) HULTHS (Handover Uplink threshold): uplink receiving intensity threshold. Signless integer, value range: 0~63, the default value is 15. 36) HULN (Handover Uplink N): value N of uplink receiving intensity. Signless integer, value range: 1~31, the default value is 4. 37) HULP (Handover UpLink P): value P of uplink receiving intensity. Signless integer, value range: 1~31, the default value is 3. 38) HDLTHS (Handover DownLink threshold): downlink receiving intensity threshold. Signless integer, value range: 0~63, the default value is 15. 39) HDLN (Handover DownLink N): value N of downlink receiving intensity. Signless integer, value range: 1~31, the default value is 4. 40) HDLP (Handover DownLink P): value P of downlink receiving intensity. Signless integer, value range: 1~31, the default value is 3. 41) HUQTHS (Handover Uplink Quality threshold): uplink receiving quality threshold. Signless integer, value range: 0~7, the default value is 4. 42) HUQN (Handover Uplink Quality N): value N of uplink receiving quality. Signless integer, value range: 1~31, the default value is 4.
Page 205 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

43) HUQP (Handover Uplink Quality P): value P of uplink receiving quality. Signless integer, value range: 1~31, the default value is 3. 44) HDQTHS (Handover Download Quality threshold): downlink receiving quality threshold . Signless integer, value range: 0~7, the default value is 4. 45) HDQN (Handover Downlink Quality N): value N of downlink receiving quality. Signless integer, value range: 1~31, the default value is 4. 46) HDQP (Handover Downlink Quality P): value P of downlink receiving quality. Signless integer, value range: 1~31, the default value is 3. 47) INHULTHS (Internal Handover UpLink Threshold ): uplink receiving intensity threshold for intra-cell handover. Signless integer, value range: 0~63, the default value is 35. 48) INHULN (Internal Handover UpLink N): value N of uplink receiving intensity for intra-cell handover. Signless integer, value range: 1~31, the default value is 4. 49) INHULP (Internal Handover UpLink P): value P of uplink receiving intensity for intra-cell handover. Signless integer, value range: 1~31, the default value is 3. 50) INHDLTHS (Internal Handover DownLink threshold): downlink receiving intensity threshold for intra-cell handover. Signless integer, value range: 0~63, the default value is 40. 51) INHDLN (Internal Handover DownLink N): value N of downlink receiving intensity for intra-cell handover. Signless integer, value range: 1~31, the default value is 4. 52) INHDLP (Internal Handover DownLink P): value P of downlink receiving intensity for intra-cell handover. Signless integer, value range: 1~31, the default value is 3.
Page 206 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

53) HOCTRL1 (Handover Control 1): whether SDCCH handover is allowed. Type Boolean, the default value is F. 54) HOCTRL2 (Handover Control 2): whether intra-cell handover due to uplink interference is allowed. Type Boolean, the default value is T. 55) HOCTRL3 (Handover Control 3): whether intra-cell handover due to downlink interference is allowed. Type Boolean, the default value is T. 56) HOCTRL4 (Handover Control 4): whether handover due to distance is allowed. Type Boolean, the default value is F. 57) HOCTRL5 (Handover Control 5): whether standard PBGT handover is allowed. Type Boolean, the default value is T. 58) HOCTRL6 (Handover Control 6): whether automatic handover based on traffic is allowed. Type Boolean, the default value is F. 59) HOCTRL7 (Handover Control 7): whether handover based on direction is allowed. Type Boolean, the default value is F. 60) HOCTRL9 (Handover Control 9): whether intra-cell handover due to downlink interference is allowed between channels of super TRX. Type Boolean, the default value is F. 61) HOCTRL10 (Handover Control 10): whether intra-cell handover due to uplink interference is allowed between channels of super TRX. Type Boolean, the default value is F. 62) HOCTRL11 (Handover Control 11): whether handover between adjacent sectors due to PBGT is allowed between channels of super TRX. Type Boolean, the default value is T. 63) HOCTRL13 (Handover Control 13): whether fast handover is allowed. Type Boolean, the default value is F. 64) HOCTRL14 (Handover Control 14): whether macro-micro delayed handover is allowed. Type Boolean, the default value is F.
Page 207 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

65) HOCTRL15 (Handover Control 15): whether micro-micro delayed handover is allowed. Type Boolean, the default value is F. 66) HOPIND1 (Handover Permission Indication 1): whether synchronous handover is allowed. Type Boolean, the default value is T. 67) HOPIND2 (Handover Permission Indication 2): whether asynchronous handover is allowed. Type Boolean, the default value is T. 68) HOPIND3 (Handover Permission Indication 3): whether quasisynchronous handover is allowed. Type Boolean, the default value is F. 69) HOPIND4 (Handover Permission Indication 4): whether asynchronous handover is allowed. Type Boolean, the default value is F. 70) LYRPRI: layer priority selection parameter of level/quality handover. Signless integer, value range: 1~3, the default value is 2. 71) LYRPBGT: layer applicable to standard PBGT handover. Signless integer, value range: 0~15, the default value is 3. 72) RPDHOTHS: fast handover threshold. Signless integer, value range: 0~63, the default value is 10. 73) RPDHON: the minimum number of times that the measured values of the uplink signal intensity are lower than the threshold continuously. Signless integer, value range: 1~31, the default value is 4. 74) MAMITHS: macro-micro handover threshold. Signless integer, value range: 0~63, the default value is 20. 75) MAMIN: macro-micro handover threshold counter. Signless integer, value range: 1~255, the default value is 2. 76) GCITHS: threshold of the carrier/interference (C/I) ratio for allowing to access a special TRX. Signless integer, value range: 0~255, the default value is 133.

Page 208 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

77) GCIN: value N of the carrier/interference (C/I) ratio for allowing to access a special TRX. Signless integer, value range: 1~31, the default value is 4. 78) GCIP: value P of the carrier/interference (C/I) ratio for allowing to access a special TRX. Signless integer, value range: 1~31, the default value is 3. 79) BADCITHS: threshold of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 0~255, the default value is 130. 80) BADCIN: value N of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 1~31, the default value is 4. 81) BADCIP: value P of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 1~31, the default value is 3. 82) TIMEADV: time advance. Signless integer, value range: 0~63, the default value is 63. 83) DISTN: value N of handover due to distance. Signless integer, value range: 1~31, the default value is 4. 84) DISTP: value P of handover due to distance. Signless integer, value range: 1~31, the default value is 3. 85) PBGTHON: value N of PGBT handover. Signless integer, value range: 1~31, the default value is 3. 86) PBGTHOP: value P of PGBT handover. Signless integer, value range: 1~31, the default value is 3. 87) HFPT: handover failure penalty period. Signless integer, value range: 1~255, the default value is 7.

Page 209 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

88) DPRIOFF: the difference value of the dynamic handover priority that can be tolerated when using the handover algorithm based on direction. Signless integer, value range: 1~7, the default value is 1. 89) PBGTOFF: the difference value of PBGT that can be tolerated when using the handover algorithm based on direction (dB). Signless integer, value range: 0~20, the default value is 3. 90) THLC: control value of traffic handover (layer). Signless integer, value range: 0~3, the default value is 1. 91) THFC: control value of traffic handover (frequency band). Signless integer, value range: 0~3, the default value is 0. 92) TTHS: traffic handover threshold (%). Signless integer, value range: 0~100, the default value is 70. 1.5.1.34 RHOD 1. Command function To delete a handover control functive . 2. Syntax structure RHOD: BSSID {, SITEID, SITENAME } {, BTSID, BTSNAME}, HOID; 3. Parameter description 1) BSSID (BSS Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40.

Page 210 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) BTSID ( BTS Identification): BTS identification number. Signless integer, value range: 2 to 127. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HOID (Handover Identification): Signless integer, value : 1. 1.5.1.35 RHOM 1. Command function To modify a handover control functive. 2. Syntax structure RHOM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, HOID: [CELLWND] [, CELLW] [, CHREQT] [, DISTWND] [, DHREQT] [, PBGTDEF] [, tPMDEF] [, RLMDEF] [, HULWND] [, HULW] [, HULHREQT] [, HDLWND] [, HDLW] [, HDLHREQT] [, HUQWND] [, HUQW] [, HUQHREQT] [, HDQWND] [, HDQW] [, HDQHREQT] [, HMRXL] [, HMRXQ] [, ZAHO] [, HOMARGIN] [, HOPRI] [, MSPWRMAX] [, RXLEVMIN] [, HINMIN] [, HULTHS] [, HULN] [, HULP] [, HDLTHS] [, HDLN] [, HDLP] [, HUQTHS] [, HUQN] [, HUQP] [, HDQTHS] [, HDQN] [, HDQP] [, INHULTHS] [, INHULN] [, INHULP] [, INHDLTHS] [, INHDLN] [, INHDLP] [, HOCTRL1] [, HOCTRL2] [, HOCTRL3] [, HOCTRL4] [, HOCTRL5] [, HOCTRL6] [, HOCTRL7] [, HOCTRL9] [, HOCTRL10] [, HOCTRL11] [, HOCTRL13] [, HOCTRL14] [, HOCTRL15] [, HOPIND1] [, HOPIND2] [, HOPIND3] [, HOPIND4] [, LYRPRI] [, LYRPBGT] [, RPDHOTHS] [, RPDHON] [, MAMITHS] [, MAMIN] [, GCITHS] [, GCIN] [, GCIP] [, BADCITHS] [, BADCIN] [, BADCIP] [, tIMEADV] [, DISTN] [, DISTP] [, PBGTHON] [, PBGTHOP] [, HFPT] [, DPRIOFF] [, PBGTOFF] [, tHLC] [, tHFC] [, tTHS]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255.
Page 211 of 591

handover

control

identification.

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HOID (Handover Identification): Signless integer, value range: 1. handover control identification.

7) CELLWND (CELL Window): the parameter for calculating the measured mean by the adjacent cell in handover control. Signless integer, value range: 1~31. 8) CELLW (CELL Weight): the weight for calculating the measured weighted mean by the adjacent cell in handover control. Signless integer, value range: 1~3. 9) CHREQT (Cell HREQT): the reserved number for calculating the measured mean by the adjacent cell in handover control. Signless integer, value range: 1. 10) DISTWND (Distance Window): the parameter for calculating the measured mean of distance in handover control. Signless integer, value range: 1~31. 11) DHREQT (Distance HREQT): the reserved number for calculating the measured mean of distance in handover control. Signless integer, value range: 1. 12) PBGTDEF (PBGT Default): the minimum default PBGT threshold required for handing over to a undefined adjacent cell. Signless integer, value range: 0~24.
Page 212 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

13) TPMDEF (Transmit Power Ms Default): the maximum default transmitting power that can be used by MS in a undefined adjacent cell. Signless integer, value range: 0~24. 14) RLMDEF: (Receive Level Ms Default): the minimum default receiving intensity threshold required for handing over to a undefined adjacent cell. Signless integer, value range: 0~63. 15) HULWND (Handover UpLink Window): the parameter for calculating the measured mean of uplink intensity in handover control. Signless integer, value range: 1~31. 16) HULW (Handover UpLink Window): the weight for calculating the weighted mean of uplink intensity in handover control. Signless integer, value range: 1~3. 17) HULHREQT (Handover UpLink HREQT): the reserved number for calculating the weighted mean of uplink intensity in handover control. Signless integer, value range: 1. 18) HDLWND (Handover DownLink Window): the parameter for calculating the measured mean of downlink intensity in handover control. Signless integer, value range: 1~31. 19) HDLW (Handover DownLink Weight): the weight for calculating the weighted mean of downlink intensity in handover control. Signless integer, value range: 1~3. 20) HDLHREQT (Handover DownLink HREQT): the reserved number for calculating the weighted mean of downlink intensity in handover control. Signless integer, value range: 1. 21) HUQWND (Handover Uplink Quality Window): the parameter for calculating the measured mean of uplink quality in handover control. Signless integer, value range: 1~31. 22) HUQW (Handover Uplink Quality Weight): the weight for calculating the weighted mean of uplink quality in handover control. Signless integer, value range: 1~3.
Page 213 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

23) HUQHREQT (Handover Uplink Quality HREQT): the reserved number for calculating the weighted mean of uplink quality in handover control. Signless integer, value range: 1. 24) HDQWND (Handover Downlink Quality Window): the parameter for calculating the measured mean of downlink quality in handover control. Signless integer, value range: 1~31. 25) HDQW (Handover Downlink Quality Weight): the weight for calculating the weighted mean of downlink quality in handover control. Signless integer, value range: 1~3. 26) HDQHREQT (Handover Downlink HREQT): the reserved number for calculating the weighted mean of downlink quality in handover control. Signless integer, value range: 1. 27) HMRXL (Handover Min Receive Level): the minimum threshold required for MS to handover to this cell due to intensity. Signless integer, value range: 0~48. 28) HMRXQ (Handover Min Receive Quality): the minimum threshold required for MS to handover to this cell due to quality. Signless integer, value range: 0~48. 29) ZAHO (Zero Accept Handover): the number of 0s that are allowed in the measured value in handover control. Signless integer, value range: 0~31. 30) HOMARGIN (Handover MARGIN): the minimum PBGT threshold required for MS to hand over to this cell. Signless integer, value range: 0~48. 31) HOPRI (Handover Priority): static priority for cell handover (8 levels). Signless integer, value range: 0~3. 32) MSPWRMAX (Ms Power MAX): the maximum transmitting power that can be used by MS in adjacent cells. Signless integer, value range: 0~31.
Page 214 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

33) RXLEVMIN (Receive Level MIN): the minimum receiving intensity level for allowing MS to hand over to the cell. Signless integer, value range: 0~63. 34) HINMIN (Handover Internal MIN): the minimum interval for continuous handover of cells. Signless integer, value range: 0~31. 35) HULTHS (Handover UpLink Threshold): uplink receiving intensity threshold. Signless integer, value range: 0~63. 36) HULN (Handover UpLink N): value N of uplink receiving intensity. Signless integer, value range: 1~31. 37) HULP (Handover UpLink P): value P of uplink receiving intensity. Signless integer, value range: 1~31. 38) HDLTHS (Handover DownLink Threshold): downlink receiving intensity threshold. Signless integer, value range: 0~63. 39) HDLN (Handover DownLink N): value N of downlink receiving intensity. Signless integer, value range: 1~31. 40) HDLP (Handover DownLink P): value P of downlink receiving intensity. Signless integer, value range: 1~31. 41) HUQTHS (Handover Uplink Quality Threshold): uplink receiving quality threshold. Signless integer, value range: 0~7. 42) HUQN (Handover Uplink Quality N): value N of uplink receiving quality. Signless integer, value range: 1~31. 43) HUQP (Handover Uplink Quality P): value P of uplink receiving quality. Signless integer, value range: 1~31. 44) HDQTHS (Handover Downlink Threshold): downlink receiving quality threshold. Signless integer, value range: 0~7. 45) HDQN (Handover Downlink Quality N): value N of downlink receiving quality. Signless integer, value range: 1~31.
Page 215 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

46) HDQP (Handover Downlink Quality P): value P of downlink receiving quality. Signless integer, value range: 1~31. 47) INHULTHS (Internal Handover UpLink Threshold): uplink receiving intensity threshold for intra-cell handover. Signless integer, value range: 0~63. 48) INHULN (Internal Handover UpLink N): value N of uplink receiving intensity for intra-cell handover. Signless integer, value range: 1~31. 49) INHULP (Internal Handover UpLink P): value P of uplink receiving intensity for intra-cell handover. Signless integer, value range: 1~31. 50) NHDLTHS (Internal Handover DownLink Threshold): downlink receiving intensity threshold for intra-cell handover. Signless integer, value range: 0~63. 51) INHDLN (Internal Handover DownLink N): value N of downlink receiving intensity for intra-cell handover. Signless integer, value range: 1~31. 52) INHDLP (Internal Handover DownLink P): value P of downlink receiving intensity for intra-cell handover. Signless integer, value range: 1~31. 53) HOCTRL1 (Handover Control 1): whether SDCCH handover is allowed. Type Boolean. 54) HOCTRL2 (Handover Control 2): whether intra-cell handover due to uplink interference is allowed. Type Boolean. 55) HOCTRL3 (Handover Control 3): whether intra-cell handover due to downlink interference is allowed. Type Boolean. 56) HOCTRL4 (Handover Control 4): whether handover due to distance is allowed. Type Boolean.
Page 216 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

57) HOCTRL5 (Handover Control 5): whether standard PBGT handover is allowed. Type Boolean. 58) HOCTRL6 (Handover Control 6): whether automatic handover based on traffic is allowed. Type Boolean. 59) HOCTRL7 (Handover Control 7): whether handover based on direction is allowed. Type Boolean. 60) HOCTRL9 (Handover Control 9): whether intra-cell handover due to downlink interference is allowed between channels of super TRX. Type Boolean. 61) HOCTRL10 (Handover Control 10): whether intra-cell handover due to uplink interference is allowed between channels of super TRX. Type Boolean. 62) HOCTRL11 (Handover Control 11): whether handover between adjacent sectors due to PBGT is allowed between channels of super TRX. Type Boolean. 63) HOCTRL12 (Handover Control 12): whether it is allowed to use the dynamic adjustment process of the handover priority. Type Boolean. 64) HOCTRL13 (Handover Control 13): whether fast handover is allowed. Type Boolean. 65) HOCTRL14 (Handover Control 14): whether macro-micro delayed handover is allowed. Type Boolean. 66) HOCTRL15 (Handover Control 15): whether micro-micro delayed handover is allowed. Type Boolean 67) HOPIND1 (Handover Permission Indication synchronous handover is allowed. Type Boolean. 1): whether

68) HOPIND2 (Handover Permission Indication2): asynchronous handover is allowed. Type Boolean.

whether

Page 217 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

69) HOPIND3 (Handover Permission Indication 3): whether quasisynchronous handover is allowed. Type Boolean. 70) HOPIND4 (Handover Permission Indication asynchronous handover is allowed. Type Boolean. 4): whether

71) LYRPRI (Layer Priority): layer priority selection parameter of level/quality handover. Signless integer, value range: 1~3. 72) LYRPBGT (Layer PBGT): layer applicable to standard PBGT handover. Signless integer, value range: 0~15. 73) RPDHOTHS (Rapid Handover Threshold): threshold. Signless integer, value range: 0~63. fast handover

74) RPDHON (Rapid Handover Number): the minimum number of times that the measured values of the uplink signal intensity are lower than the threshold continuously. Signless integer, value range: 1~31. 75) MAMITHS (Macro Micro Threshold): macro-micro handover threshold. Signless integer, value range: 0~63. 76) MAMIN (Macro Micro Number): macro-micro handover threshold counter. Signless integer, value range: 1~255. 77) GCITHS (GCI Threshold): threshold of the carrier/interference (C/I) ratio for allowi ng to access a special TRX. Signless integer, value range: 0~255. 78) GCIN (GCI N): value N of the carrier/interference (C/I) ratio for allowing to access a special TRX. Signless integer, value range: 1~31. 79) GCIP (GCI P): value P of the carrier/interference (C/I) ratio for allowing to access a special TRX. Signless integer, value range: 1~31. 80) BADCITHS (BAD CI Threshold): threshold of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 1~255.
Page 218 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

81) BADCIN (BAD CI N): value N of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 1~31. 82) BADCIP (BAD CI P): value P of the carrier/interference (C/I) ratio for outgoing handover from a special TRX. Signless integer, value range: 1~31. 83) TIMEADV (Time Advance): time advance. Signless integer, value range: 0~63. 84) DISTN (Distance N): value N of handover due to distance. Signless integer, value range: 1~31. 85) DISTP (Distance P): value P of handover due to distance. Signless integer, value range: 1~31. 86) PBGTHON (PBGT Handover N): value N of PGBT handover. Signless integer, value range: 1~31. 87) PBGTHOP (PBGT Handover P): value P of PGBT handover. Signless integer, value range: 1~31. 88) HFPT (Handover Failure Penalty): handover failure penalty period. Signless integer, value range: 1~255. 89) DPRIOFF (DPRIOFF): the difference value of the dynamic handover priority that can be tolerated when using the handover algorithm based on direction. Signless integer, value range: 1~7. 90) PBGTOFF (PBGTOFF): the difference value of PBGT that can be tolerated when using the handover algorithm based on direction (dB). Signless integer, value range: 0~20. 91) THLC (Traffic Handover Level Control): control value of traffic handover (layer). Signless integer, value range: 0~3. 92) THFC (Traffic Handover Frequency Control): control value of traffic handover (frequency band). Signless integer, value range: 0~3.
Page 219 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

93) TTHS (Traffic Threshold): traffic handover threshold (%). Signless integer, value range: 0~100. 1.5.1.36 RHOQ 1. Command function To query a handover control object. 2. Syntax structure RHOQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, HOID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HOID (HandoverControl Identification): handover control identification number. Signless integer, value range: 1~1. 1.5.1.37 RHRC 1. Command function

Page 220 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To add a functional adjacent cell handover and reselection object. 2. Syntax structure RHRC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: HRID: SYNC, PRI, MTPMAX, RLMIN: ISRCELL, NCLAYER: RHOECMO: PSSUPPORT, EXC_ACC, LSA_ID, RAC, CELBRAC2, RXLEVASN, MSTXMCCH, RESELOFF, tMPOFFST, PNLTIME, HCS_EXST, HCS_THR, PRIOCLS; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts identification): cell number. Signless integer, value range: 13. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HRID (Handover Reselection Identification): identification number of adjacent cell handover object. Signless integer, value range: 65 to 96. 7) SYNC (Sync): indicating whether to synchronize the current cell with adjacent cells. Type Boolean, with a value of T or F, the default value is T. 8) PRI (Priority): priority level for cell h andover. Signless integer, value range: 0~7, the default is 3. 9) MTPMAX (Ms Transmit Power Max): maximum transmitting power of MS in the adjacent cell. Signless integer, value range: 1~31, the default is 5.
Page 221 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

10) RLMIN ( Receive Level Min): minimum signal level for MS to receive in the handover target cell. Signless integer, value range: 0~63, the default is 15. 11) SRCELL (Is Related Cell): indicating whether the current cell and adjacent cell are related cells. Type Boolean, with a value of T or F, the default value is F. 12) NCLAYER (Near Cell Layer): neighboring cell layer. Signless integer, value range: 0~3, the default is 0. 13) RHOECMO (Related Handover External Cell MO): DN of the handover cell (HOC): BssId -SiteId -BtsId-HoId or DN of an external cell: EcId. Composite signless integer. 14) PSSUPPORT : whether GPRS is supported. Type Boolean.

15) EXC_ACC: whether the MS with SoLSA dedicated access right is allowed for access. Type Boolean. 16) LSA_ID : LSA identification (the lowest 24 bits are effective). Signless integer. 17) RAC: RA_CODE. Signless integer.

18) CELBRAC2: cell reselection status CELL_BAR_ACCESS_2. Type Boolean. 19) RXLEVASN: the minimum receiving level for allowing MS to access the GPRS system GPRS_RXLEV_ACCESS_MIN . Signless integer. 20) MSTXMCCH: the maximum power used by the MS before the network power control information is received (GPRS_TXPWR_MAX_CCH). Signless integer. 21) RESELOFF: cell reselection offset. Signless integer.

22) TMPOFFST: temporary offset for cell reselection . Signless integer.


Page 222 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

23)

PNLTIME: penalty time for cell reselection . Signless integer.

24) HCS_EXIST: whether the HCS parameter exists in the cell. Type Boolean. 25) HCS_THR: HCS signal intensity threshold of the cell. Type Boolean. 26) 1.5.1.38 RHRD 1. Command function To delete the adjacent cell handover and reselection object of a cell. 2. Syntax structure RHRD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, HRID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. PRIOCLS: HCS priority of the cell. Signless integer.

Page 223 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) HRID (Handover Reselection Identification): identification number of adjacent cell handover object. Signless integer, value range: 65 to 96. 1.5.1.39 RHRM 1. Command function To modify the radio parameters of an adjacent cell handover and reselection object. 2. Syntax structure RHRM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, HRID: [SYNC] [, PRI] [, MTPMAX] [, RLMIN] [, ISRCELL] [, NCLAYER] [PSSUPPORT ] [, EXC_ACC ] [, LSA_ID ] [, RAC ] [, CELBRAC2 ] [, RXLEVASN ] [, MSTXMCCH ] [, RESELOFF] [, tMPOFFST] [, PNLTIME ] [, HCS_EXST ] [, HCS_THR ] [, PRIOCLS]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HRID (Handover Reselection Identification): identification number of the adjacent cell handover and reselection object. Signless integer, value range: 65 to 96.
Page 224 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) SYNC (Sync): indicating whether to synchronize the current cell with adjacent cells. Type Boolean, with a value of T or F, the default value is T. 8) PRI (Priority): priority level for cell handover. Signless integer, value range: 0~7, the default is 3. 9) MTPMAX (Ms Transmit Power Max): maximum transmitting power of MS in the adjacent cell. Signless integer, value range: 1~31, the default is 5. 10) RLMIN ( Receive Level Min): minimum signal level for MS to receive in the handover target cell. Signless integer, value range: 0~63, the default is 15. 11) ISRCEL (Is Related Cell): indicating whether the current cell and adjacent cell are related cells. Type Boolean, with a value of T or F, the default value is F. 12) NCLAYER (Near Cell Layer): neighboring cell layer. Signless integer, value range: 0~3, the default is 0. 13) PSSUPPORT : whether GPRS is supported. Type Boolean.

14) EXC_ACC: whether the MS with SoLSA dedicated access right is allowed for access. Type Boolean. 15) LSA_ID : LSA identification (the lowest 24 bits are effective ). Signless integer. 16) RAC: RA_CODE. Signless integer.

17) CELBRAC2: cell reselection status CELL_BAR_ACCESS_2. Type Boolean. 18) RXLEVASN: the minimum receiving level for allowing MS to access the GPRS system GPRS_RXLEV_ACCESS_MIN. Signless integer.

Page 225 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

19) MSTXMCCH: the maximum power used by MS before receiving the network power control information GPRS_TXPWR_MAX_CCH. Signless integer. 20) RESELOFF: cell reselection offset. Signless integer.

21) TMPOFFST: temporary offset for cell reselection . Signless integer. 22) PNLTIME: penalty time for cell reselection . Signless integer.

23) HCS_EXIST: whether the HCS parameter exists in the cell. Type Boolean. 24) HCS_THR: HCS signal intensity threshold of the cell. Type Boolean. 25) 1.5.1.40 RHRQ 1. Command function To view the parameters of an adjacent cell handover and reselection object. 2. Syntax structure RHRQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, HRID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024.
Page 226 of 591

PRIOCLS: HCS priority of the cell. Signless integer.

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) HRID (Handover Reselection Identification): identification number of adjacent cell handover object. Signless integer, value range: 65 to 96. 7) PARAGRP (Parameter Group): radio parameter attribute package type. Enumerated type, value range: ALL, the default value is ALL. 1.5.1.41 RICC 1. Command function To add an interference cell object of a cell. 2. Syntax structure RICC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: ICID: RBTSECMO; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40.

Page 227 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) ICID (Interfere Cell Identification): identification number of the interference cell object. Signless integer, value range: 1~6. 7) RBTSECMO (Related BTS External Cell MO): DN of the related BTS: BssId-SiteId -BtsId or DN of an external cell under this BSS: EcId. Composite signless integer. 1.5.1.42 RICD 1. Command function To delete the interference cell of a cell. 2. Syntax structure RICD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, ICID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3.

Page 228 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) ICID (Interfere Cell Identification): identification number of the interference cell object. Signless integer, value range: 1~6. 1.5.1.43 RICQ 1. Command function To view the radio parameters of the interference cell of a cell. 2. Syntax structure RICQ: BSSID {, SITEID, SITENAME}{, BTSID, BTSNAME}, ICID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) ICID (Interfere Cell Identification): identification number of the interference cell object. Signless integer, value range: 1~6.

Page 229 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) PARAGRP (Parameter Group): radio parameter package attribute type. Enumerated type, value range: ALL, the default value is ALL. 1.5.1.44 RLLC 1. Command function To add a new LAPD link object. 2. Syntax structure RLLC: BSSID, LAPDID: PCMNO, PCMTS: LOCTEI; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) LAPDID (LapdLink Identification): LAPD LINK IDENTIFICATION NUMBER. Signless integer, value range: 1~2304. 3) PCMNO (Pcm No): PcmCircuit number, the PCM line of the Abis interface. Signless integer, value range: 1~384. 4) PCMTS (Pcm Time Slot): PCM time slot. Signless integer, value range: 0~31. 5) LOCTEI (Local Terminal Endpoint Identifier): refers to the terminal identifier in a time slot. Signless integer, value range: 0~4. 1.5.1.45 RLLD 1. Command function To delete a LAPD link object. 2. Syntax structure

Page 230 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

RLLD: BSSID, LAPDID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) LAPDID (LapdLink Identification): LAPD LINK IDENTIFICATION NUMBER. Signless integer, value range: 1~2304. 1.5.1.46 RLLQ 1. Command function To query a LAPD link object. 2. Syntax structure RLLQ: BSSID, LAPDID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) LAPDID (LapdLink Identification): LAPD LINK IDENTIFICATION NUMBER. Signless integer, value range: 1~2304. 1.5.1.47 RPCC 1. Command function To add a new power control functive. 2. Syntax structure RPCC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: PCID: PINCSTEP, PREDSTEP, PCINTERV: PULWND, PULW, PULHREQT:
Page 231 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

PDLWND, PDLW, PDLHREQT: PUQWND, PUQW, PUQHREQT: PDQWND, PDQW, PDQHREQT: PCUL, PCDL: PLULTHS, PLULN, PLULP: PLDLTHS, PLDLN, PLDLP: PLUQTHS, PLUQN, PLUQP: PLDQTHS, PLDQN, PLDQP: PUULTHS, PUULN, PUULP: PUDLTHS, PUDLN, PUDLP: PUUQTHS, PUUQN, PUUQP: PUDQTHS, PUDQN, PUDQP: MTPMAX, MTPMIN, BTPMIN, RAPIDPI, PCRPTPRD: PRL0, PRL1, PRL2, PRL3, PRL4, PRL5, PRL6, PRL7: ULPWCTRL, DLPWCTRL, SS_BTS, PWCTRMOD, PWCTRLEV, P0; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) PCID (Power Control Identification): power control identification. Signless integer, value range: 1, the default value is 1. 7) PINCSTEP (Power Increase Step): increasing step length of MS transmitting power. Signless integer, value range: 0~2, the default value is 0. 8) PREDSTEP (Power Reduce Step): reducing step length of MS transmitting power. Signless integer, value range: 0, 1. the default value is 0.

Page 232 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) PCINTERV (Power Change Interval): the minimum time interval for changing RF power level. Signless integer, value range: 0~32, the default value is 2. 10) PULWND (Power Uplink Window): the number of examples used for calculating the measured mean of uplink intensity in power control. Signless integer, value range: 1~31, the default value is 6. 11) PULW (Power Uplink Weight): the weight used for calculating the weighted mean of uplink intensity in power control. Signless integer, value range: 1~3, the default value is 2. 12) PULHREQT (Power Uplink HREQT): the reserved number used for calculating the weighted mean of uplink intensity in power control. Signless integer, value range: 1, the default value is 1. 13) PDLWND (Power Downlink Window): the number of examples used in calculating the measured mean of downlink intensity in power control. Signless integer, value range: 1~31, the default value is 6. 14) PDLW (Power Downlink Weight): the weight used for calculating the weighted mean of downlink intensity in power control. Signless integer, value range: 1~3, the default value is 2. 15) PDLHREQT (Power Downlink HREQT): the reserved number used for calculating the weighted mean of downlink intensity in power control. Signless integer, value range: 1, the default value is 1. 16) PUQWND (Power Uplink Quality Window): the number of examples used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1~31, the default value is 6. 17) PUQW (Power Uplink Quality Weight): the weight used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1~3, the default value is 2. 18) PUQHREQT (Power Uplink HREQT): the reserved number used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1, the default value is 1.
Page 233 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

19) PDQWND (Power Downlink Quality Window): the number of examples used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1~31, the default value is 6. 20) PDQW (Power Downlink Quality Weight): the weight used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1~3, the default value is 2. 21) PDQHREQT (Power Downlink Quality HREQT): the reserved number used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1, the default value is 1. 22) PCUL (Power Control Uplink): whether power control is allowed in the uplink direction. Type Boolean, the default value is True. 23) PCDL (Power Control Downlink): whether power control is allowed in the downlink direction. Type Boolean, the default value is False. 24) PLULTHS (Power Low Uplink Threshold): the lower threshold of uplink signal power. Signless integer, value range: 0~63, the default value is 22. 25) PLULN (Power Low Uplink N): value N in the lower limit parameter of uplink signal power. Signless integer, value range: 1~31, the default value is 4. 26) PLULP (Power Low Uplink P): value P in the lower limit parameter of uplink signal power. Signless integer, value range: 1~31, the default value is 3. 27) PLDLTHS (Power Low Downlink Threshold): the lower threshold of downlink signal power. Signless integer, value range: 0~63, the default value is 26. 28) PLDLN (Power Low Downlink N): value N in the lower limit parameter of downlink signal power. Signless integer, value range: 1~31, the default value is 4.

Page 234 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

29) PLDLP (Power Low Downlink P): value P in the lower limit parameter of downlink signal power. Signless integer, value range: 1~31, the default value is 3. 30) PLUQTHS (Power Low Uplink Quality Threshold): the lower threshold of uplink signal quality. Signless integer, value range: 0~7, the default value is 2. 31) PLUQN (Power Low Uplink Quality N): value N in the lower limit parameter of uplink signal quality. Signless integer, value range: 1~31, the default value is 4. 32) PLUQP (Power Low Uplink Quality P): value P in the lower limit parameter of uplink signal quality. Signless integer, value range: 1~31, the default value is 3. 33) PLDQTHS (Power Low Downlink Quality Threshold): the lower threshold of downlink signal quality. Signless integer, value range: 0~7, the default value is 2. 34) PLDQN (Power Low Downlink Quality N): value N in the lower limit parameter of downlink signal quality. Signless integer, value range: 1~31, the default value is 4. 35) PLDQP (Power Low Downlink Quality P): value P in the lower limit parameter of downlink signal quality. Signless integer, value range: 1~31, the default value is 3. 36) PUULTHS (Power Up Uplink Threshold): the upper threshold of uplink signal power. Signless integer, value range: 0~63, the default value is 30. 37) PUULN (Power Up Uplink N): value N in the upper limit parameter of uplink signal power. Signless integer, value range: 1~31, the default value is 4. 38) PUULP (Power Up Uplink P): value P in the upper limit parameter of uplink signal power. Signless integer, value range: 1~31, the default value is 3.
Page 235 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

39) PUDLTHS (Power Up Downlink Threshold): the upper threshold of downlink signal power. Signless integer, value range: 0~63, the default value is 34. 40) PUDLN (Power Up Downlink N): value N in the upper limit parameter of downlink signal power. Signless integer, value range: 1~31, the default value is 4. 41) PUDLP (Power Up Downlink P): value P in the upper limit parameter of downlink signal power. Signless integer, value range: 1~31, the default value is 3. 42) PUUQTHS (Power Up Uplink Quality Threshold): the upper threshold of uplink signal quality. Signless integer, value range: 0~7, the default value is 0. 43) PUUQN (Power Up Uplink Quality N): value N in the upper limit parameter of uplink signal quality. Signless integer, value range: 1~31, the default value is 4. 44) PUUQP (Power Up Uplink Quality P): value P in the upper limit parameter of uplink signal quality. Signless integer, value range: 1~31, the default value is 3. 45) PUDQTHS (Power Up Downlink Quality Threshold): the upper threshold of downlink signal quality. Signless integer, value range: 0~7, the default value is 0. 46) PUDQN (Power Up Downlink Quality N): value N in the upper limit parameter of downlink signal quality. Signless integer, value range: 1~31, the default value is 4. 47) PUDQP (Power Up Downlink Quality P): value P in the upper limit parameter of downlink signal quality. Signless integer, value range: 1~31, the default value is 3. 48) MTPMAX (Ms Transit Power Max): maximum power level of MS. Signless integer, value range: 0~31, the default value is 5.
Page 236 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

49) MTPMIN (Ms Transit Power Min): minimum power level of MS. Signless integer, value range: 0~31, the default value is 16. 50) BTPMIN (Bs Transmit Power Min): minimum power level of BS. Signless integer, value range: 0~15, the default value is 10. 51) RAPIDPI (Rapid Power Identification): whether the fast power control process can be used. Type Boolean, the default value is False. 52) PCRPTPRD (Power Control Report Period): power control performance measurement report period (51 multi-frames). Signless integer, value range: 1~255, the default value is 240. 53) PRL0 (Power Reduce Level 0): the maximum power decreasing value of the 0th quality level. Signless integer, value range: 0~38, the default value is 24. 54) PRL1 (Power Reduce Level 1): the maximum power decreasing value of the 1st quality level. Signless integer, value range: 0~38, the default value is 22. 55) PRL2 (Power Reduce Level 2): the maximum power decreasing value of the 2nd quality level. Signless integer, value range: 0~38, the default value is 20. 56) PRL3 (Power Reduce Level 3): the maximum power decreasing value of the 3rd quality level. Signless integer, value range: 0~38, the default value is 18. 57) PRL4 (Power Reduce Level 4): the maximum power decreasing value of the 4th quality level. Signless integer, value range: 0~38, the default value is 16. 58) PRL5 (Power Reduce Level 5): the maximum power decreasing value of the 5th quality level. Signless integer, value range: 0~38, the default value is 14.

Page 237 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

59) PRL6 (Power Reduce Level 6): the maximum power decreasing value of the 6th quality level. Signless integer, value range: 0~38, the default value is 12. 60) PRL7 (Power Reduce Level 7): the maximum power decreasing value of the 7th quality level. Signless integer, value range: 0~38, the default value is 10. 61) 62) ULPWCTRL: uplink power control strategy. Signless integer. DLPWCTRL: downlink power control strategy. Signless integer.

63) SS_BTS: signal intensity of the MS expected to be received. Signless integer. 64) 65) 66) 1.5.1.48 RPCD 1. Command function To delete a power control functive. 2. Syntax structure RPCD: BSSID {, SITEID, SITENAME } {, BTSID, BTSNAME}, PCID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024.
Page 238 of 591

PWCTRMOD: power control mode. Signless integer. PWCTRLEV: power control level. Signless integer. P0: P0. Signless integer.

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITENAME (Site Name): site identification name. Character string type, the length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the length is 40. 6) PCID (Power Control Identification): power control identification. Signless integer, value range: 1. 1.5.1.49 RPCM 1. Command function To modify a power control functive. 2. Syntax structure RPCM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, PCID: [PINCSTEP] [, PREDSTEP] [, PCINTERV] [, PULWND] [, PULW] [, PULHREQT] [, PDLWND] [, PDLW] [, PDLHREQT] [, PUQWND] [, PUQW] [, PUQHREQT] [, PDQWND] [, PDQW] [, PDQHREQT] [, PCUL] [, PCDL] [, PLULTHS] [, PLULN] [, PLULP] [, PLDLTHS] [, PLDLN] [, PLDLP] [, PLUQTHS] [, PLUQN] [, PLUQP] [, PLDQTHS] [, PLDQN] [, PLDQP] [, PUULTHS] [, PUULN] [, PUULP] [, PUDLTHS] [, PUDLN] [, PUDLP] [, PUUQTHS] [, PUUQN] [, PUUQP] [, PUDQTHS] [, PUDQN] [, PUDQP] [, MTPMAX] [, MTPMIN] [, BTPMIN] [, RAPIDPI] [, PCRPTPRD] [, PRL0] [, PRL1] [, PRL2] [, PRL3] [, PRL4] [, PRL5] [, PRL6] [, PRL7] [ULPWCTRL ] [, DLPWCTRL ] [, SS_BTS ] [, PWCTRMOD ] [, PWCTRLEV ] [, P0]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024.
Page 239 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) PCID (Power Control Identification): power control identification. Signless integer, value range: 1, the default value is 1. 7) PINCSTEP (Power Increase Step): increasing step length of MS transmitting power. Signless integer, value range: 0~2. 8) PREDSTEP (Power Reduce Step): reducing step length of MS transmitting power. Signless integer, value range: 0~1. 9) PCINTERV (Power Change Interval): the minimum time interval for RF power adjustment. Signless integer, value range: 0~32. 10) PULWND (Power Uplink Window): the number of examples used for calculating the measured mean of uplink intensity in power control. Signless integer, value range: 1~31. 11) PULW (Power Uplink Weight): the weight used for calculating the weighted mean of uplink intensity in power control. Signless integer, value range: 1~3. 12) PULHREQT (Power Uplink HREQT): the reserved number used for calculating the weighted mean of uplink intensity in power control. Signless integer, value range: 1, the default value is 1. 13) PDLWND (Power Downlink Window): the number of examples used in calculating the measured mean of downlink intensity in power control. Signless integer, value range: 1~31.

Page 240 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

14) PDLW (Power Downlink Weight): the weight used for calculating the weighted mean of downlink intensity in power control. Signless integer, value range: 1~3. 15) PDLHRQT (Power Downlink HREQT): the reserved number used for calculating the weighted mean of downlink intensity in power control. Signless integer, value range: 1, the default value is 1. 16) PUQWND (Power Uplink Quality Window): the number of examples used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1~31. 17) PUQW (Power Uplink Quality Weight): the weight used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1~3. 18) PUQHREQT (Power Uplink Quality HREQT): the reserved number used for calculating the measured mean of uplink quality in power control. Signless integer, value range: 1, the default value is 1. 19) PDQWND (Power Downlink Quality Window): the number of examples used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1~31. 20) PDQW (Power Downlink Quality Weight): the weight used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1~3. 21) PDQHREQT (Power Downlink Quality HREQT): the reserved number used for calculating the measured mean of downlink quality in power control. Signless integer, value range: 1. 22) PCUL (Power Control Uplink): whether power control is allowed in the uplink direction. Type Boolean. 23) PCDL (Power Control Downlink): whether power control is allowed in the downlink direction. Type Boolean.

Page 241 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

24) PLULTHS (Power Low Uplink Threshold): the lower threshold of uplink signal power. Signless integer, value range: 0~63. 25) PLULN (Power Low Uplink N): value N in the lower limit parameter of uplink signal power. Signless integer, value range: 1~31. 26) PLULP (Power Low Uplink P): value P in the lower limit parameter of uplink signal power. Signless integer, value range: 1~31. 27) PLDLTHS (Power Low Downlink Threshold): the lower threshold of downlink signal power. Signless integer, value range: 0~63. 28) PLDLN (Power Low Downlink N): value N in the lower limit parameter of downlink signal power. Signless integer, value range: 1~31. 29) PLDLP (Power Low Downlink P): value P in the lower limit parameter of downlink signal power. Signless integer, value range: 1~31. 30) PLUQTHS (Power Low Uplink Quality Threshold): the lower threshold of uplink signal quality. Signless integer, value range: 0~7. 31) PLUQN (Power Low Uplink Quality N): value N in the lower limit parameter of uplink signal quality. Signless integer, value range: 1~31. 32) PLUQP (Power Low Uplink Quality P): value P in the lower limit parameter of uplink signal quality. Signless integer, value range: 1~31. 33) PLDQTHS (Power Low Downlink Quality Threshold): the lower threshold of downlink signal quality. Signless integer, value range: 0~7. 34) PLDQN (Power Low Downlink Quality N): value N in the lower limit parameter of downlink signal quality. Signless integer, value range: 1~31. 35) PLDQP (Power Low Downlink Quality P): value P in the lower limit parameter of downlink signal quality. Signless integer, value range: 1~31.

Page 242 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

36) PUULTHS (Power Up Uplink Threshold): the upper threshold of uplink signal power. Signless integer, value range: 0~63. 37) PUULN (Power Up Uplink N): value N in the upper limit parameter of uplink signal power. Signless integer, value range: 1~31. 38) PUULP (Power Up Uplink P): value P in the upper limit parameter of uplink signal power. Signless integer, value range: 1~31. 39) PUDLTHS (Power Up Downlink Threshold): the upper threshold of downlink signal power. Signless integer, value range: 0~63. 40) PUDLN (Power Up Downlink N): value N in the upper limit parameter of downlink signal power. Signless integer, value range: 1~31. 41) PUDLP (Power Up Downlink P): value P in the upper limit parameter of downlink signal power. Signless integer, value range: 1~31. 42) PUUQTHS (Power Up Uplink Quality Threshold): the upper threshold of uplink signal quality. Signless integer, value range: 0~7. 43) PUUQN ( Power Uplink Quality N): value N in the upper limit parameter of uplink signal quality. Signless integer, value range: 1~31. 44) PUUQP (Power Up Uplink Quality P): value P in the upper limit parameter of uplink signal quality. Signless integer, value range: 1~31. 45) PUDQTHS (Power Up Downlink Quality Threshold): the upper threshold of downlink signal quality. Signless integer, value range: 0~7. 46) PUDQN (Power Up Downlink Quality N): value N in the upper limit parameter of downlink signal quality. Signless integer, value range: 1~31. 47) PUDQP (Power Up Downlink Quality P): value P in the upper limit parameter of downlink signal quality. Signless integer, value range: 1~31.

Page 243 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

48) MTPMAX (Ms Transmit Power Max): maximum power level of MS. Signless integer, value range: 0~31. 49) MTPMIN (Ms Transmit Power Min): : minimum power level of MS. Signless integer, value range: 0~31. 50) BTPMIN (Bs Transmit Power Min): minimum power level of BS. Signless integer, value range: 0~15. 51) RAPIDPI (Rapid Power Identification): whether the fast power control process can be used. Type Boolean, the default value is False. 52) PCRPTPRD (Power Control Report Period): power control performance measurement report period (51 multi-frames). Signless integer, value range: 1~255. 53) PRL0 (Power Reduce Level 0): the maximum power decreasing value of the 0th quality level. Signless integer, value range: 0~38. 54) PRL1 (Power Reduce Level 1): the maximum power decreasing value of the 1st quality level. Signless integer, value range: 0~38. 55) PRL2 (Power Reduce Level 2): the maximum power decreasing value of the 2nd quality level. Signless integer, value range: 0~38. 56) PRL3 (Power Reduce Level 3): the maximum power decreasing value of the 3rd quality level. Signless integer, value range: 0~38. 57) PRL4 (Power Reduce Level 4): the maximum power decreasing value of the 4th quality level. Signless integer, value range: 0~38. 58) PRL5 (Power Reduce Level 5): the maximum power decreasing value of the 5th quality level. Signless integer, value range: 0~38. 59) PRL6 (Power Reduce Level 6): the maximum power decreasing value of the 6th quality level. Signless integer, value range: 0~38. 60) PRL7 (Power Reduce Level 7): the maximum power decreasing value of the 7th quality level. Signless integer, value range: 0~38.
Page 244 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

61) 62)

ULPWCTRL: uplink power control strategy. Signless integer. DLPWCTRL: downlink power control strategy. Signless integer.

63) SS_BTS: signal intensity of the MS expected to be received. Signless integer. 64) 65) 66) 1.5.1.50 RPCQ 1. Command function To query a power control object. 2. Syntax structure RPCQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, PCID: PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the length is 40. 4) BTSID (Bts Identification): cell identification number. Signless integer, value range: 1~3. PWCTRMOD: power control mode. Signless integer. PWCTRLEV: power control level. Signless integer. P0: P0. Signless integer.

Page 245 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BTSNAME (Bts Name): cell identification name. Character string type, the length is 40. 6) PCID (Power Control Identification): power control identification. Signless integer, value range: 1. 1.5.1.51 RPMC 1. Command function To add a new PCM line object. 2. Syntax structure RPMC: BSSID, PCMID: RPCMMO; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) PCMID (PcmCircuit Identification): PcmCircuit identification number. Signless integer, value range: 1~384. 3) RPCMNO (Related Pcm No): DN of the related PCM device MO (MunitUnit-PcmNo).Composite signless integer. 1.5.1.52 RPMD 1. Command function To delete a PCM line object. 2. Syntax structure RPMD: BSSID, PCMID; 3. Parameter description
Page 246 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) PCMID (PcmCircuit Identification): PcmCircuit identification number. Signless integer, value range: 1~384. 1.5.1.53 RPMQ 1. Command function To view a PCM line object. 2. Syntax structure RPMQ: BSSID, PCMID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) PCMID (Pcm Circuit Identification): PCM circuit identification number. Signless integer, value range: 1~384. 1.5.1.54 RRCC 1. Command function To add a new radio carrier object. 2. Syntax structure RRCC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}: RCID: RCLIST, PWRCLASS, tXPWRRED; 3. Parameter description

Page 247 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the default length is 40. 6) RCID (Radio Carrier Identification): radio carrier identification. Signless integer, value range: 1~36. 7) RCLIST (RadioCarrier Frequency List): radio carrier frequency list. Composite signless integer, value range: a subset of the BTS frequency set. 8) PWRCLASS (Power Class): maximum transmitting power of carrier frequency. Signless integer, value range: 1~8. 9) TXPWRRED (TX Power Max Reduction): transmitting power adjustment. Signless integer, value range: 0~6. The default value is 0. 1.5.1.55 RRCD 1. Command function To delete a radio carrier object. 2. Syntax structure RRCD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, RCID;

Page 248 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the default length is 40. 6) RCID (Radio Carrier Identification): radio carrier identification. Signless integer, value range: 1~36. 1.5.1.56 RRCM 1. Command function To modify a radio carrier object. 2. Syntax structure RRCM: BSSID {, SITEID, SITENAME}, { BTSID, BTSNAME}, RCID: RCLIST, MODIMODE, tXPWRRED; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024.
Page 249 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the default length is 40. 6) RCID (Radio Carrier Identification): radio carrier identification. Signless integer, value range: 1~36. 7) RCLIST (RadioCarrier Frequency List): radio carrier frequency list. Composite signless integer, value range: a subset of the BTS frequency set. 8) MODIMODE (Modification Mode): modification mode. Signless integer, value range: 0 to 2. Among them, : 0: re-set; 1: add frequency point; 2: delete frequency point. 9) TXPWRRED (TX Power Max Reduction): transmitting power adjustment. Signless integer, value range: 0~6. The default value is 0. 1.5.1.57 RRCQ 1. Command function To query a radio carrier object. 2. Syntax structure RRCQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, RCID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255.

Page 250 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the default length is 40. 6) RCID (Radio Carrier Identification): radio carrier identification. Signless integer, value range: 1~36. 1.5.1.58 RSIC 1. Command function To add a functional base station management entity. 2. Syntax structure RSIC: BSSID: SITEID, ALIAS: LOCNAME: MODULENO: RESITEMO: ROAMLAPD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) ALIAS (Alias): alias. Character string type, the maximum length is 40. 4) LOCNAME (Location Name): resource location information. Character string type, the maximum length is 40. default value: China.
Page 251 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) MODULENO (Module No.): peripheral module number. Signless integer, value range: 2 to 64. 6) RESITEMO (Related Equipment Site MO): DN of the physical SITE related to the BSS (ESiteId).Composite signless integer, value range: 1~1024. 7) ROAMLAPD (Radio Operation And Maintenance LAPD): operation and maintenance channel LapdLink. Composite signless integer, set the parameter as LapdLinkId for BTSV1A, and set the parameter RackNo1LapdLinkId 1&RackNo2-LapdLinkId 2&RackNo3-LapdLinkId 3 for BTSV2. 1.5.1.59 RSID 1. Command function To delete a radio base station management object. 2. Syntax structure RSID: BSSID {, SITEID, SITENAME}; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 1.5.1.60 RSIM 1. Command function To modify the radio parameters of a ZTEBTSSITEMANAGER object.
Page 252 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure RSIM: BSSID {, SITEID, SITENAME}: [ALIAS ] [, LOCNAME] [, ROAMLAPD]; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) ALIAS (Alias): alias. Character string type, the maximum length is 40. 5) LOCNAME (LocName): resource location information. Character string type, the maximum length is 40. 6) ROAMLAPD (ROamLapd): LAPD link. Signless integer, the default value is 0. 1.5.1.61 RSIQ 1. Command function The view the radio parameters of a ZTEBTSSITEMANAGER object. 2. Syntax structure RSIQ: BSSID {, SITEID, SITENAME} : PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255.
Page 253 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) PARAGRP (Parameter Group): parameter group to be queried. Enumerated type, value range: ALL, the default value is ALL. 1.5.1.62 RTXA 1. Command function To modify the administration state attribute of a baseband transceiver object.. 2. Syntax structure RTXA: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID : AD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40.

Page 254 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. L: locking state; U: unlocking state; S: time delay blocking. 1.5.1.63 RTXC 1. Command function To add a new baseband transceiver object. 2. Syntax structure RTXC: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME} : TRXID, tRXTYPE : RPANELMO : RTLAPD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36.

Page 255 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) TRXTYPE (Transceiver Type): transceiver type. Signless integer, value range: 0, 1. Among them, : 0: normal; 1: special. The default value is 0. 8) RPANELMO (Related Panel MO): related BTS physical panel, ESiteId Rack-Shelf-Panel. Composite signless integer. 9) RTLAPD (Related Telecom Lapd): related LAPD link under this BSS. Signless integer, value range: 1~3840. 1.5.1.64 RTXD 1. Command function To delete a baseband transceiver object. 2. Syntax structure RTXD: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36.
Page 256 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.1.65

RTXM 1. Command function To modify a baseband transceiver object. 2. Syntax structure RTXM: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME} : TRXID, RRCID, RTLAPD; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITE ID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) RRCID (Related RadioCarrier Identification): whether it is related to RadioCarrier. Signless integer, relating stands for baseband frequency hopping. Value range: 0~36. 8) RTLAPD (Related Telecom Lapd): related LAPD link under this BSS. Signless integer, value range: 1~3840.

Page 257 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.1.66

RTXQ 1. Command function To query a baseband transceiver object. 2. Syntax structure RTXQ: BSSID {, SITEID, SITENAME} {, BTSID, BTSNAME}, tRXID : PARAGRP; 3. Parameter description 1) BSSID (Bss Function Identification): BSS identification number. Signless integer, value range: 1~255. 2) SITEID (Site Identification): site identification number. Signless integer, value range: 1~1024. 3) SITENAME (Site Name): site identification name. Character string type, the maximum length is 40. 4) BTSID (Bts Identification): cell number. Signless integer, value range: 1~3. 5) BTSNAME (Bts Name): cell identification name. Character string type, the maximum length is 40. 6) TRXID (Transceiver Identification): transceiver identification number. Signless integer, value range: 1~36. 7) PATAGRP (Parameter Group): radio parameter attribute package type. Enumerated type, value range: STATES, ALL, the default value is ALL. ? ? ALL is for querying static attribute information, STATES is for querying dynamic attribute information.

Page 258 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.2 1.5.2.1

Man-machine commands of software loading ZBOC 1. Command function To create a BtsGeOsu (GeOsu of BTS) software version. 2. Syntax structure ZBOC: {EBSCID, EBSCNAME}, SITETYPE, BTYPE, MODULENO: FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) SITETYPE (Site Type): BTS SITE type. Signless integer, value range: 1~7. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 6) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12.

1.5.2.2

ZBOD 1. Command function


Page 259 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To delete BtsGeOsu (GeOsu of BTS) software version. 2. Syntax structure ZBOD: {EBSCID, EBSCNAME}, SITETYPE, BTYPE, MODULENO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) SITETYPE (Site Type): BTS SITE type. Signless integer, value range: 1~7. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 1.5.2.3 ZBOM 1. Command function To modify a BtsGeOsu (GeOsu of BTS) software version. 2. Syntax structure ZBOM: {EBSCID, EBSCNAME}, SITETYPE, BTYPE, MODULENO: FILEVER; 3. Parameter description

Page 260 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) SITETYPE (Site Type): BTS SITE type. Signless integer, value range: 1~7. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 6) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.4 ZBOQ 1. Command function To query a BtsGeOsu (GeOsu of BTS) software version. 2. Syntax structure ZBOQ: {EBSCID, EBSCNAME}, SITETYPE, BTYPE, MODULENO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 261 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) SITETYPE (Site Type): BTS SITE type. Signless integer, value range: 1~7. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 1.5.2.5 ZBOR 1. Command function To load a BtsGeOsu (GeOsu of BTS) software version. 2. Syntax structure ZBOR: {EBSCID, EBSCNAME}, SITETYPE, BTYPE, MODULENO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) SITETYPE (Site Type): BTS SITE type. Signless integer, value range: 1~7. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC.

Page 262 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 1.5.2.6 ZDPC 1. Command function To create the BSCSpecOsu software version of a DSP chip. 2. Syntax structure ZDPC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO: SOSUID: FILEID, FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8. 7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0.

Page 263 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) FILEID (File Identification): software file identification. enumerated type, the enumerated values are as follows: BSC_FR, BSC_EFRBSC_EFRENBSC_HRBSC_BRPDSP. 9) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.7 ZDPD 1. Command function To delete the BSCSpecOsu software version of a DSP chip. 2. Syntax structure ZDPD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8.

Page 264 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0. 1.5.2.8 ZDPM 1. Command function To modify the BSCSpecOsu software version of a DSP chip. 2. Syntax structure ZDPM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO, SOSUID: FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8. 7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0. 8) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12.
Page 265 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.2.9

ZDPQ 1. Command function To query the BSCSpecOsu software version of a DSP chip. 2. Syntax structure ZDPQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8. 7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0.

1.5.2.10

ZDPR 1. Command function To load a DSP software version.


Page 266 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ZDPR: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8. 7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0. 1.5.2.11 ZDSV 1. Command function To query the software version running on the foreground of a DSP chip. 2. Syntax structure ZDSV: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO, OSUID: OPTIONS;

Page 267 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No): DSP number. Signless integer, value range: from 1 to 8. 7) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range0. 8) OPTIONS ( Options ): options . Signless integer, value range is 2. 1.5.2.12 ZGOC 1. Command function To create a GeOsu software version. 2. Syntax structure ZGOC: {EBSCID, EBSCNAME}, BIGTYPE, BTYPE: FILEVER: OPTIONS, SENDMDLE; 3. Parameter description

Page 268 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) BIGTYPE (Site Type): big type. Signless integer, value range: 1~5. 4) BTYPE (Board Type): BSC board type. enumerated type, the enumerated values are as follows : MP, DSN2B, SMB, SMT1, SMT2, DRT20, EDRT20, DTI, FR, EFR, EFREN, HR, NSPP, FSPP, tCPP, AIPP, BIPP, GIPP, BRP, FRP, MPPP, MPMP, MTP, 2MMTP, LAPD, PUC, BRP, FRP, GIPP, BRPDSP. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 6) OPTIONS (Options): options. Signless integer, value range: 0, 1. 2, 3, 4. This attribute is effective only for MP loading, and it is specified as 1 in other conditions. 7) SENDMDLE (Send Module No): sending BSC module number. Signless integer, value range: 0, 1. 2, 3, 4, 5, 6, 7, 8, in which 0 stands for all peripheral modules. 1.5.2.13 ZGOD 1. Command function To delete a GeOsu software version. 2. Syntax structure ZGOD: {EBSCID, EBSCNAME}, BIGTYPE, BTYPE; 3. Parameter description

Page 269 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) BIGTYPE (Site Type): big type. Signless integer, value range: 1~5. 4) BTYPE (Board Type): BSC board type. enumerated type, the enumerated values are as follows : MP, DSN2B, SMB, SMT1, SMT2, DRT20, EDRT20, DTI, FR, EFR, EFREN, HR, NSPP, FSPP, tCPP, AIPP, BIPP, GIPP, BRP, FRP, MPPP, MPMP, MTP, 2MMTP, LAPD, PUC, BRP, FRP, GIPP, BRPDSP. 1.5.2.14 ZGOM 1. Command function To modify a GeOsu software version. 2. Syntax structure ZGOM: {EBSCID, EBSCNAME}, BIGTYPE, BTYPE: FILEVER: OPTIONS, SENDMDLE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) BIGTYPE (Site Type): big type. Signless integer, value range: 1~5. 4) BTYPE (Board Type): BSC board type. enumerated type, the enumerated values are as follows : MP, DSN2B, SMB, SMT1, SMT2, DRT20, EDRT20, DTI, FR, EFR, EFREN, HR, NSPP, FSPP, tCPP, AIPP,
Page 270 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

BIPP, GIPP, BRP, FRP, MPPP, MPMP, MTP, 2MMTP, LAPD, PUC, BRP, FRP, GIPP, BRPDSP. 5) FILEVER (File Version): version number of software file . Character string type, the maximum length of the character string is 12. 6) OPTIONS (Options): options . Signless integer, value range: 0, 1. 2, 3, 4. This attribute is effective only for MP loading, and it is specified as 1 in other conditions. 7) SENDMDLE (Send Module No): sending BSC module number. Signless integer, value range: 0, 1. 2, 3, 4, 5, 6, 7, 8, in which 0 stands for all peripheral modules. 1.5.2.15 ZGOQ 1. Command function To query a GeOsu software version. 2. Syntax structure ZGOQ: {EBSCID, EBSCNAME}, BIGTYPE, BTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) BIGTYPE (Site Type): big type. Signless integer, value range: 1~5. 4) BTYPE (Board Type): BSC board type. enumerated type, the enumerated values are as follows : MP, DSN2B, SMB, SMT1, SMT2, DRT20, EDRT20, DTI, FR, EFR, EFREN, HR, NSPP, FSPP, tCPP, AIPP,

Page 271 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

BIPP, GIPP, BRP, FRP, MPPP, MPMP, MTP, 2MMTP, LAPD, PUC, BRP, FRP, GIPP, BRPDSP. 1.5.2.16 ZGOR 1. Command function To load a GeOsu software version. 2. Syntax structure ZGOR: {EBSCID, EBSCNAME}, BIGTYPE, BTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) BIGTYPE (Site Type): big type. Signless integer, value range: 1~5. 4) BTYPE (Board Type): BSC board type. enumerated type, the enumerated values are as follows : MP, DSN2B, SMB, SMT1, SMT2, DRT20, EDRT20, DTI, FR, EFR, EFREN, HR, NSPP, FSPP, tCPP, AIPP, BIPP, GIPP, BRP, FRP, MPPP, MPMP, MTP, 2MMTP, LAPD, PUC, BRP, FRP, GIPP, BRPDSP. 1.5.2.17 ZSBC 1. Command function To create a BSCSpecOsu software version. 2. Syntax structure

Page 272 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ZSBC: EBSCID {, EBSCNAME}, MODULENO, MUNIT, UNIT: SOSUID: FILEID, FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range: 0~1. Generally, if two boards related to a unit are used as active/standby boards, then 0 stands for the left board, and 1 stands for the right board. 7) FILEID (File Identification): software file identification. Enumerated type, the enumerated values are as follows: BSC_BOSN, BSC_SMB, BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_MP, BSC_IPCBEN, BSC_MTPEN, BSC_LAPDEN, BSC_FR, BSC_EFR, BSC_EFRC6, BSC_HR, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 8) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.18 ZSBD 1. Command function To delete a BSCSpecOsu software version.
Page 273 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ZSBD: EBSCID {, EBSCNAME }, MODULENO, MUNIT, UNIT, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range: 0~1. Generally, if two boards related to a unit are used as active/standby boards, then 0 stands for the left board, and 1 stands for the right board. 1.5.2.19 ZSBM 1. Command function To modify a BSCSpecOsu software version. 2. Syntax structure ZSBM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, SOSUID: FILEVER; 3. Parameter description

Page 274 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range: 0~1. Generally, if two boards related to a unit are used as active/standby boards, then 0 stands for the left board, and 1 stands for the right board. 7) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.20 ZSBQ 1. Command function To query a BSCSpecOsu software version. 2. Syntax structure ZSBQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 275 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range: 0~1. Generally, if two boards related to a unit are used as active/standby boards, then 0 stands for the left board, and 1 stands for the right board. 1.5.2.21 ZSBR 1. Command function To load a BSCSpecOsu software version. 2. Syntax structure ZSBR: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, SOSUID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255.

Page 276 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) SOSUID (ZteOsu Identification): ID of OSU. Signless integer, value range: 0~1. Generally, if two boards related to a unit are used as active/standby boards, then 0 stands for the left board, and 1 stands for the right board. 1.5.2.22 ZSIC 1. Command function To create the software version of a BTS board (BtsSiteSpecOsu). 2. Syntax structure ZSIC: EBSSID {, EBSSNAME}, ESITEID, BTYPE: FILEVER; 3. Parameter description 1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12.
Page 277 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.2.23

ZSID 1. Command function To delete the software version of a BTS board (BtsSiteSpecOsu) 2. Syntax structure ZSID: EBSSID {, EBSSNAME}, ESITEID, BTYPE; 3. Parameter description 1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC.

1.5.2.24

ZSIM 1. Command function To modify the software version of a BTS board (BtsSiteSpecOsu) 2. Syntax structure ZSIM: EBSSID {, EBSSNAME}, ESITEID, BTYPE: FILEVER; 3. Parameter description

Page 278 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.25 ZSIQ 1. Command function To query the software version of a BTS board (BtsSiteSpecOsu). 2. Syntax structure ZSIQ: EBSSID {, EBSSNAME}, ESITEID, BTYPE; 3. Parameter description 1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024.

Page 279 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 1.5.2.26 ZSIR 1. Command function To load the software version of a BTS board (BtsSiteSpecOsu) ; 2. Syntax structure ZSIR: EBSSID {, EBSSNAME}, ESITEID, BTYPE; 3. Parameter description 1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 4) BTYPE (Board Type): BTS board type. enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 1.5.2.27 ZSWC 1. Command function To create a storage software version. 2. Syntax structure
Page 280 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ZSWC: {EBSCID, EBSCNAME }, MODULENO, FILEID, FILEVER: SRCPATH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 4) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 5) FILEID (File Identification): software file identification. E numerated type, the enumerated values are as follows: BSC_MP, BSC_BOSN, BSC_SMB, BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_FR, BSC_EFR, BSC_EFREN, BSC_HR, BSC_GPP, BSC_GIPP, BSC_BRP, BSC_FRP, BSC_IPCBEN, BSC_IPCBEN, BSC_MTPEN, BSC_2MMTPEN, BSC_LAPDEN, BTS_OMU, BTS_FUC, BTS_CHP, BTSV2_CMM, BTSV2_CLG, BTSV2_FUC, BTSV2_FLG, BTSV2_CHP, BTSV2_CIP, BTS_SCU, BTS_DSP0, BTS_DSP1, BTS_RCU, BTS_ETDC, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 6) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.28 ZSWD 1. Command function To delete a storage software version. 2. Syntax structure ZSWD: {EBSCID, EBSCNAME}, MODULENO, FILEID, FILEVER;
Page 281 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, in which 0 stands for all peripheral modules. 4) FILEID (File Identification): software file identification. Enumerated type, the enumerated values are as follows: BSC_MP, BSC_BOSN, BSC_SMB, BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_FR, BSC_EFR, BSC_EFREN, BSC_HR, BSC_GPP, BSC_GIPP, BSC_BRP, BSC_FRP, BSC_IPCBEN, BSC_IPCBEN, BSC_MTPEN, BSC_2MMTPEN, BSC_LAPDEN, BTS_OMU, BTS_FUC, BTS_CHP, BTSV2_CMM, BTSV2_CLG, BTSV2_FUC, BTSV2_FLG, BTSV2_CHP, BTSV2_CIP, BTS_SCU, BTS_DSP0, BTS_DSP1, BTS_RCU, BTS_ETDC, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.29 ZSWM 1. Command function To modify a storage software version. 2. Syntax structure ZSWM: {EBSCID, SRCPATH; EBSCNAME}, MODULENO, FILEID, FILEVER:

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.
Page 282 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 4) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 5) FILEID (File Identification): software file identification. Enumerated type, the enumerated values are as follows: BSC_MP, BSC_BOSN, BSC_SMB, BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_FR, BSC_EFR, BSC_EFREN, BSC_HR, BSC_GPP, BSC_GIPP, BSC_BRP, BSC_FRP, BSC_IPCBEN, BSC_IPCBEN, BSC_MTPEN, BSC_2MMTPEN, BSC_LAPDEN, BTS_OMU, BTS_FUC, BTS_CHP, BTSV2_CMM, BTSV2_CLG, BTSV2_FUC, BTSV2_FLG, BTSV2_CHP, BTSV2_CIP, BTS_SCU, BTS_DSP0, BTS_DSP1, BTS_RCU, BTS_ETDC, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 6) SRCPATH (Source Path): file path. Character string type, the maximum length is 80. 1.5.2.30 ZSWN 1. Command function To send a storage software version to MP. 2. Syntax structure ZSWN: {EBSCID, EBSCNAME}, MODULENO, FILEID, FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 283 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 4) FILEID (File Identification): software file identification. Enumerated type, the enumerated values are as follows: BSC_MP, BSC_BOSN, BSC_SMB, BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_FR, BSC_EFR, BSC_EFREN, BSC_HR, BSC_GPP, BSC_GIPP, BSC_BRP, BSC_FRP, BSC_IPCBEN, BSC_IPCBEN, BSC_MTPEN, BSC_2MMTPEN, BSC_LAPDEN, BTS_OMU, BTS_FUC, BTS_CHP, BTSV2_CMM, BTSV2_CLG, BTSV2_FUC, BTSV2_FLG, BTSV2_CHP, BTSV2_CIP, BTS_SCU, BTS_DSP0, BTS_DSP1, BTS_RCU, BTS_ETDC, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.31 ZSWQ 1. Command function To query a storage software version. 2. Syntax structure ZSWQ: {EBSCID, EBSCNAME}, MODULENO, FILEID, FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No): BSC module number. Signless integer, value range: 0~255, 0 stands for all peripheral modules. 4) FILEID (File Identification): software file identification. Enumerated type, the enumerated values are as follows: BSC_MP, BSC_BOSN, BSC_SMB,
Page 284 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

BSC_SMT1, BSC_SMT2, BSC_DRT, BSC_EDRT, BSC_DTI, BSC_FR, BSC_EFR, BSC_EFREN, BSC_HR, BSC_GPP, BSC_GIPP, BSC_BRP, BSC_FRP, BSC_IPCBEN, BSC_IPCBEN, BSC_MTPEN, BSC_2MMTPEN, BSC_LAPDEN, BTS_OMU, BTS_FUC, BTS_CHP, BTSV2_CMM, BTSV2_CLG, BTSV2_FUC, BTSV2_FLG, BTSV2_CHP, BTSV2_CIP, BTS_SCU, BTS_DSP0, BTS_DSP1, BTS_RCU, BTS_ETDC, BSC_PUC, BSC_BRP, BSC_FRP, BSC_GIPP, BSC_BRPDSP. 5) FILEVER (File Version): version number of software file. Character string type, the maximum length of the character string is 12. 1.5.2.32 ZSYV 1. Command function To query the software version of a BSC board running on the foreground. 2. Syntax structure ZSYV: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): BTYPE, OPTIONS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No): BSC rack number. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No): BSC shelf number. Signless integer, value range: 1~6. 5) SLOTNO (Slot No): BSC board slot number. Signless integer, value range: 1~27.
Page 285 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) BTYPE (Board Type): BSC board type. Enumerated type, the enumerated values are as follows: DTI, DSN, CKI, DSNI, SYCK, PWRB, SMB, SMT1, SMT2, DSN2B, AIPP, BIPP, tCPP, NSPP, FSPP, ATIC, BTIC, INTERNALTIC, COMI, DRT20, EDRT20, PWRP, GIPP, PUC, GTIC, BRP, FRP. 7) OPTIONS (Options): options. Signless integer, value range: 0~3. 0: querying BOOT version; 1: querying application program version; 2: querying DSP version; 3: querying MP version. 1.5.2.33 ZTPV 1. Command function To query the software version of a board running on the foreground of BTS. 2. Syntax structure ZTPV: EBSSID {, EBSSNAME}, PANELNO: PTYPE, BTYPE; 3. Parameter description 1) EBSSID: BSS Equipment Identification. Signless integer, value range: 1~255. 2) EBSSNAME: BSS Equipment Name.. Character string type, the maximum length of the character string is 40. 3) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 4) RACKNO (RACK NUMBER): BTS rack number. Signless integer, value range: 1~4. 5) SHELFNO (SHELF NUMBER): BTS shelf number. Signless integer, value range: 1~5.
Page 286 of 591

ESITEID,

RACKNO,

SHELFNO,

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PANELNO (PANEL NUMBER): BTS panel number. Signless integer, value range: 1~16. 7) PTYPE (PANEL TYPE): BTS panel type. Enumerated type, the enumerated values are as follows: OMU, EOMU, tRU, CMM, tRM, MBSCU, MBTRX, ETDC, STRU. 8) BTYPE (Board Type): board type. Enumerated type, the enumerated values are as follows: OMU, EOMU, FU, CHP, B2CMM, B2CMMLOG, B2FUC, B2FUCLOG, B2CHP, B2CIP, MBSCU, MBDSP0, MBDSP1, MBRFIU, ETDC. 1.5.3 1.5.3.1 Man-machine commands of integrated configuration management EACC 1. Command function To create the COM of A interface time slots. 2. Syntax structure EACC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: AIPPTS: TCPPMU, tCPPUNIT, tCPPHW, tCPPTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127.
Page 287 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW number of AIPP. Signless integer, value range: 1~16. 7) AIPPTS (Aipp Ts): time slot number of AIPP. Signless integer, value range: 0~127. 8) TCPPMU (Tcpp Multiple Unit): multi-unit name of TCPP. Signless integer, value range: 2 to 127. 9) TCPPUNIT (Tcpp Unit): TCPP unit name. Signless integer, value range: 0~16. 10) TCPPHW (Tcpp Hw): TCPP HW number. Signless integer, value range: 1~16. 11) TCPPTS (Tcpp Ts): TCPP time slot number. Signless integer, value range: 0~127. 1.5.3.2 EACD 1. Command function To delete the COM of A interface time slots. 2. Syntax structure EACD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, AIPPTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 288 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW number of AIPP. Signless integer, value range: 1~16. 7) AIPPTS (Aipp Ts): time slot number of AIPP. Signless integer, value range: 0~127. 1.5.3.3 EACQ 1. Command function To view the COM attribute of A interface time slots. 2. Syntax structure EACQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, AIPPTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127.
Page 289 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW number of AIPP. Signless integer, value range: 1~16. 7) AIPPTS (Aipp Ts): time slot number of AIPP. Signless integer, value range: 0~127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.4 EATA 1. Command function To modify the status attribute of A interface trunk circuits. 2. Syntax structure EATA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: AD, SPY; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20.

Page 290 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L (locking state), U (unlocking state), S (time delay blocking). 9) SPY: Spy status attribute. Signless integer, value range: 0~1. 1.5.3.5 EATC 1. Command function To create an A interface trunk circuit. 2. Syntax structure EATC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: TS, tRKGRP, CICNO: AIPPHW, AIPPTS: TNETHW, tNETTS, tNETSTS: KIND; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4.
Page 291 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) TRKGRP (Trunk Group): trunk circuit group . Signless integer, value range: 0~7. 9) CICNO (Circuit No.): circuit number. Signless integer, value range: 0~255. 10) AIPPHW (Aipp Hw): HW number of AIPP. Signless integer, value range: 1~16. 11) AIPPTS (Aipp Time Slot): time slot number of AIPP. Signless integer, value range: 0~127. 12) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64. 13) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 14) TNETSTS (Tnet Time Slot): T net sub-time slot number. Signless integer, value range: 0~255. 15) KIND (Kind): trunk circuit type. Signless integer, value range: 0~5. 0: the trunk circuit is used for voice channel; 1: the trunk circuit is used for operation and maintenance; 2: the trunk circuit is used for CCS; 3: reserved; 4: the trunk circuit is used for EAM; 5: the trunk circuit is used for transparent channel. 1.5.3.6 EATD 1. Command function To delete an A interface trunk relation. 2. Syntax structure EATD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS;
Page 292 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 1.5.3.7 EATQ 1. Command function To view the attribute of an A interface trunk circuit. 2. Syntax structure EATQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 293 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, the default value is ALL. 1.5.3.8 EAUA 1. Command function To modify the AUCTS status attribute of a Gb interface. 2. Syntax structure EAUA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, AUCCFG: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1.

Page 294 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): SPCU multi-unit name, it is unnecessary to specify the unit name because the master control unit is always the No.0 unit. Signless integer, value range: 0~127, the default value is 0. 5) AUCCFG (AucCfg): AucCfg. Signless integer, value range: 1, the default value is 1. 6) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.9 EAUC 1. Command function To create AUCTS of Gb interface. 2. Syntax structure EAUC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, GIUMUNIT, GIPPHW, tNETHW, BRPGPRS, FRPGPRS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name, it is unnecessary to specify the unit name because the master control unit is always the No.0 unit. Signless integer, value range: 0~127, the default value is 0. AUCCFG:

Page 295 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) AUCCFG (AucCfg): AucCfg. Signless integer, value range: 1, the default value is 1. 6) GIUMUNIT (GiuMunit): GIU multi-unit name. Signless integer, value range: 0~127. 7) GIPPHW (GippHw): the 8M HW line for connecting GIPP with AUC. Signless integer, value range: 9 to 16. 8) TNETHW (Tnet HW): the No. of the 8M HW line from AUC to BOSN. Signless integer, value range: 1~64. 9) BRPGPRS (Brpgprs): number of active BRP boards. Signless integer. 10) FRPGPRS (Frpgprs): number of active FRP boards. Signless integer. 1.5.3.10 EAUD 1. Command function To delete AUCTS of Gb interface. 2. Syntax structure EAUD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, AUCCFG; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1.

Page 296 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): SPCU multi-unit name, it is unnecessary to specify the unit name because the master control unit is always the No.0 unit. Signless integer, value range: 0~127, the default value is 0. 5) AUCCFG (AucCfg): AucCfg. Signless integer, value range: 1, the default value is 1. 1.5.3.11 EAUM 1. Command function To modify AUCTS of Gb interface. 2. Syntax structure EAUM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, GIUMUNIT, GIPPHW, tNETHW, BRPGPRS, FRPGPRS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name, it is unnecessary to specify the unit name because the master control unit is always the No.0 unit. Signless integer, value range: 0~127, the default value is 0. 5) AUCCFG (AucCfg): AucCfg. Signless integer, value range: 1, the default value is 1. 6) GIUMUNIT (GiuMunit): GIU multi-unit name. Signless integer, value range: 0~127.
Page 297 of 591

AUCCFG:

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) GIPPHW (GippHw): the 8M HW line for connecting GIPP with AUC. Signless integer, value range: 9 to 16. 8) TNETHW (Tnet HW): the No. of the 8M HW line from AUC to BOSN. Signless integer, value range: 1~64. 9) BRPGPRS (Brpgprs): number of active BRP boards. Signless integer. 10) FRPGPRS (Frpgprs): number of active FRP boards. Signless integer. 1.5.3.12 EAUQ 1. Command function To view the AUCTS attribute of Gb interface. 2. Syntax structure EAUQ: {EBSCID, PARAGRP; EBSCNAME}, MODULENO, MUNIT, AUCCFG:

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name, it is unnecessary to specify the unit name because the master control unit is always the No.0 unit. Signless integer, value range: 0~127, the default value is 0.

Page 298 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) AUCCFG (AucCfg): AucCfg. Signless integer, value range: 1, the default value is 1. 6) PARAGRP (Parameter Group): attribute package type. 1.5.3.13 EBCC 1. Command function This command is used to create a BSC. 2. Syntax structure EBCC: EBSCID (BSC Equipment Identification): ALIAS, VERSION: L, B: {MSCID, MSCNAME}: OPC, SPTYPE, tESTCODE, tESTID, AM: LECM; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification. Signless integer, value range1~255. 2) ALIAS (Alias): BSC alias. Character string type, The maximum length of the character string is 40. 3) VERSION (Version): BSC enumerated items: 10, 20. version number. Enumerated type,

4) L (Latitude): latitude coordinates of BSC location. Floating -point type, value range: -180 to 180, the default value is 0. 5) B (Longitude): longitude coordinates of BSC location. Floating-point type, value range: -90 to 90, the default value is 0. 6) MSCID (MSC Identification): MSC identification number of the BSC. Signless integer, value range: 1~255. 7) MSCNAME (MSC Name): MSC identification name of the BSC. Character string type, The maximum length of the character string is 40.
Page 299 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) OPC (Ordinant Point Code): BSC signaling point code. Signless integer, value range: 1~16383. 9) SPTYPE (Signaling Point Type): signaling point type. Signless integer, value range: 1~3. the default value is 3. Among them, 1: signaling end point (SEP); 2: signaling transfer point (STP); 3: signaling end/transfer point (STEP). 10) TESTCODE (Test Code): test code. Character string type, The maximum length of the character string is 16. the default value is 0000000000000000. 11) TESTID (Test Identification): whether test flag is required. Type Boolean, the default value is T. 12) AM (Associated Mode): the connecting relationship between MSC signaling point and BSC signaling point. Signless integer, value range: 1~2. the default value is 1. Among them, 1 : Associated Mode; 2: Quasi-associated Mode. 13) LECM (Link Error Correct Method): link error correction method; Signless integer, value range: 1~2. the default value is 1. Among them, 1: basic error correction method, with a transmission time delay less than or equal to 15ms. 1.5.3.14 EBCD 1. Command function To delete a BSC (the radio BSC must be deleted first). 2. Syntax structure EBCD: {EBSCID, EBSCNAME}; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification. Signless integer, value range: 1~255.
Page 300 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC identification name. 1.5.3.15 EBCM 1. Command function To modify the attribute value of an object BSC identification. 2. Syntax structure EBCM: {EBSCID, EBSCNAME}: [ALIAS][, L][, B][, OPC][, tESTCODE][, tESTID][, AM][, LECM]; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC identification name. Character string type, The maximum length of the character string is 40. 3) ALIAS (Alias): new BSC alias. Character string type, The maximum length of the character string is 40. 4) L (Latitude): latitude coordinates of BSC location. Floating -point type, value range: -180~180. 5) B (Longitude): o l ngitude coordinates of BSC location. Floating-point type, value range: -90~90. 6) OPC (Ordinant Point Code): BSC signaling point code. Signless integer, value range: 1~16383. 7) TESTCODE (Test Code): test code. Character string type, maximum length of the character string is 16. The

8) TESTID (Test Identification): whether test flag is required. Type Boolean.


Page 301 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) AM (Associated Mode): the connecting relationship between MSC signaling point and BSC signaling point. Signless integer, value range: 1~2. Among them, 1: Associated Mode; 2: Quasi-associated Mode. 10) LECM (Link Error Correct Method): link error correction method. Signless integer, value range: 1~2. Among them, 1: basic error correction method, with a transmission time delay less than or equal to 15ms; 2: preventive cyclic resending (PCR) correction method, with a transmission time delay greater than or equal to 15ms. 1.5.3.16 EBCQ 1. Command function To view the attribute of an object BSC. 2. Syntax structure EBCQ: {EBSCID, EBSCNAME}: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC identification name. Character string type, The maximum length of the character string is 40. 3) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, the enumerated items include ALL. 1.5.3.17 EBFA 1. Command function To modify the configuration status attribute of a BRP board. 2. Syntax structure
Page 302 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EBFA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 8 to 16. 7) AD (Administer State): administration state. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.18 EBFC 1. Command function To create BRPCFG. 2. Syntax structure EBFC: {EBSCID , EBSCNAME}, MODULENO, MUNIT, UNIT: AUCHW; 3. Parameter description

Page 303 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. 1.5.3.19 EBFD 1. Command function To delete BRPCFG. 2. Syntax structure EBFD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1.

Page 304 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 8 to 16. 1.5.3.20 EBFQ 1. Command function To view BRPCFG attribute. 2. Syntax structure EBFQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 8 to 16.

Page 305 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: STATES, STATIC, the default value is ALL. 1.5.3.21 EBHA 1. Command function To modify the status attribute of a physical bearer channel (BRCH) of Gb interface. 2. Syntax structure EBHA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, SPCUMUNT: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): 2M PCM line of TIC . Signless integer, value range: 1~4. 7) SPCUMUNT (SPCU Munit): SPCU multi-unit name, 0 stands for Unconfigured. Signless integer.

Page 306 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.22 EBHC 1. Command function To create a physical bearer channel (BRCH) of Gb interface. 2. Syntax structure EBHC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: SPCUMUNT, AUCFRPNO, N391, N392, N393, t391, AR; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): 2M PCM line of TIC . Signless integer, value range: 1~4. 7) SPCUMUNT (SPCU Munit): SPCU multi-unit name, 0 stands for Unconfigured. Signless integer.

Page 307 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) AUCFRPNO (AUC Frp No): the sequence number allocated in the 8M HW between GIPP and AUC of the bearer channel (1~4), 0 stands for Unconfigured, Signless integer. 9) N391 (N391): the polling counter of all PVC statuses. Signless integer. 10) 11) N392 (N392): failure threshold. Signless integer. N393 (N393): detection event counter. Signless integer.

12) T391 (T391): polling timer for link integrity confirmation (unit: 10ms). Signless integer. 13) 1.5.3.23 EBHD 1. Command function To delete a physical bearer channel (BRCH) of Gb interface.. 2. Syntax structure EBHD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, SPCUMUNT; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. AR (AR): access rate (number of effective 64kb/s time slots).

Page 308 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): 2M PCM line of TIC . Signless integer, value range: 1~4. 7) SPCUMUNT (SPCU Munit): SPCU multi-unit name, 0 stands for Unconfigured. Signless integer. 1.5.3.24 EBHM 1. Command function To modify a physical bearer channel (BRCH) of Gb interface.. 2. Syntax structure EBHM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, SPCUMUNT: AUCFRPNO, N391, N392, N393, t391, AR; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit. Signless integer, value range: 0~20.

Page 309 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PCMNO (Pcm No .): 2M PCM line of TIC . Signless integer, value range: 1~4. 7) SPCUMUNT (SPCU Munit): SPCU multi-unit name, 0 stands for Unconfigured. Signless integer. 8) AUCFRPNO (AUC Frp No): the sequence number allocated in the 8M HW between GIPP and AUC of the bearer channel (1~4), 0 stands for Unconfigured. Signless integer. 9) N391 (N391): the polling counter of all PVC statuses. Signless integer. 10) 11) N392 (N392): failure threshold. Signless integer. N393 (N393): detection event counter. Signless integer.

12) T391 (T391): polling timer for link integrity confirmation (unit: 10ms). Signless integer. 13) 1.5.3.25 EBHQ 1. Command function To view the attribute of a physical bearer channel (BRCH) of Gb interface.. 2. Syntax structure EBHQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, SPCUMUNT: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. AR (AR): access rate (number of effective 64kb/s time slots).

Page 310 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): 2M PCM line of TIC . Signless integer, value range: 1~4. 7) SPCUMUNT (SPCU Munit): SPCU multi-unit name, 0 stands for Unconfigured. Signless integer. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.26 EBNA 1. Command function To modify the status attribute of BUS484 under a monitor board. 2. Syntax structure EBNA: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BUSNO, ADDR: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40.
Page 311 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No .): BSC slot No. Signless integer, value range: 0~27. 6) BUSNO (Bus No.): Bus number. Signless integer, value range: 1~8. 7) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 8) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.27 EBNC 1. Command function To create BUS485 under a monitor board. 2. Syntax structure EBNC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BUSNO: ADDR, LINKPORT, MUNIT; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16.

Page 312 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No .): BSC slot No. Signless integer, value range: 0~27. 6) BUSNO (Bus No .): Bus number. Signless integer, value range: 1~8. 7) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 8) LINKPORT (Link Port): port number. Signless integer, value range: 0~65535. 9) MUNIT (Multiple Unit): multi-unit name. Signless integer, the default value is 0, value range: 2 to 127. 1.5.3.28 EBND 1. Command function To delete BUS485 under a monitor board. 2. Syntax structure EBND: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BUSNO, ADDR; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16.

Page 313 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No .): BSC slot No. Signless integer, value range: 0~27. 6) BUSNO (Bus No .): Bus number. Signless integer, value range: 1~8. 7) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 1.5.3.29 EBNQ 1. Command function To view the BUS485 attribute under a monitor board. 2. Syntax structure EBNQ: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BUSNO, ADDR: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No .): BSC slot No. Signless integer, value range: 0~27. 6) BUSNO (Bus No .): Bus number. Signless integer, value range: 1~8.

Page 314 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: ALL, the default value is ALL. 1.5.3.30 EBTA 1. Command function To modify the status attribute of Abis interface trunk circuit. 2. Syntax structure EBTA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS, SUBTS: SPY; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, default value is 1. the

4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) SUBTS (Sub Time Slot): sub-time slot number. Signless integer, value range: 0~255.
Page 315 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) SPY: administration state attribute.. Signless integer, value range: 0~1. 1.5.3.31 EBTC 1. Command function To create an Abis interface trunk circuit. 2. Syntax structure EBTC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: SUBTS: BIPPUNIT, BIPPHW, BIP PTS, BIPPTS: TNETHW, tNETTS, tNETSTS: KIND: SITEID, BTSID, tRXID, tN; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, default value is 1. the

4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) SUBTS (Sub Time Slot): sub-time slot number. Signless integer, value range: 0~255.

Page 316 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) BIPPUNIT (Bipp Unit): BIPP unit name. Signless integer, value range: 0~20. 10) BIPPHW (Bipp Hw): BIPP HW number. Signless integer, value range: 1~16. 11) BIPPTS (Bipp Time Slot): BIPP time slot number. Signless integer, value range: 0~127. 12) BIPPSTS (Bipp Sub Time Slot): BIPP sub-time slot number. Signless integer, value range: 0~255. 13) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64. 14) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 15) TNETSTS (Tnet Sub Time Slot): T net sub-time slot number. Signless integer, value range: 0~255. 16) KIND (Kind): trunk circuit type. Signless integer, value range: 1~5. Among them, 1: the trunk circuit is used for voice channel; 2: the trunk circuit is used for OMU operation and maintenance; 3: the trunk circuit is used for TRU operation and maintenance; 4: EAM transparent channel; 5: multi-TS transparent channel. 17) SITEID (Site Identification): logic site identification. Signless integer, value range: 0, this value needs to be filled automatically by the radio part. 18) BTSID (Bts Identification): logic cell identification. Signless integer, value range: 0, this value needs to be filled automatically by the radio part. 19) TRXID (Trx Identification): logic transceiver identification. Signless integer value, value range: 0, this value needs to be filled automatically by the radio part.
Page 317 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

20) TN (Trunk No.): connection time slot number. Signless integer, value range: 0, this value needs to be filled automatically by the radio part. 1.5.3.32 EBTD 1. Command function To delete an Abis interface trunk circuit. 2. Syntax structure EBTD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UUNIT, PCMNO, tS, SUBTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module number. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) SUBTS (Sub Time Slot): sub-time slot number. Signless integer, value range: 0~255.

Page 318 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.33

EBTQ 1. Command function To view the attribute of an Abis interface trunk circuit. 2. Syntax structure EBTQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS, SUBTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO: module number. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 7) TS (Time Slot): time slot number. Signless integer, value range: 0~31. 8) SUBTS (Sub Time Slot): sub-time slot number. Signless integer, value range: 0~255. 9) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, the default value is ALL.

Page 319 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.34

EBUA 1. Command function To modify the status attribute of BUS485 under multi-unit. 2. Syntax structure EBUA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BUSNO, ADDR: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, default value is 1. the

4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BUSNO (Bus No.): Bus number. Signless integer, value range: 1~8. 6) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 7) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.35 EBUC 1. Command function To create a BUS485 under multi-unit.
Page 320 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EBUC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BUSNO: ADDR, LINKPORT, CSlOTNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BUSNO (Bus No .): Bus number. Signless integer, value range: 1~8. 6) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 7) LINKPORT (Link Port): port number. Signless integer, value range: 0~65535. 8) CSLOTNO (Control Slot No.): control layer slot number. Signless integer, value range: 0, the default value is 0. 1.5.3.36 EBUD 1. Command function To delete a BUS485 under multi-unit. 2. Syntax structure EBUD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BUSNO, ADDR;
Page 321 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, The maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, default value is 1. the

4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BUSNO (Bus No .): Bus number. Signless integer, value range: 1~8. 6) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 1.5.3.37 EBUQ 1. Command function To view the attribute of a BUS485 (under multi-unit). 2. Syntax structure EBUQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BUSNO, ADDR: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 322 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BUSNO (Bus No.): Bus number. Signless integer, value range: 1~8. 6) ADDR (Address): bus address. Signless integer, value range: 2 to 127. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: ALL, the default value is ALL. 1.5.3.38 EDCC 1. Command function To create DropCom. 2. Syntax structure EDCC: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS: BIESUBTS: PCMOUT, tSOUT, SUBTSOUT; 3. Parameter description 1) EBSSID (BSS Identification): connected BSS identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, string ? the maximum length is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. Character

Page 323 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BIEPCM (BIE Pcm): No. of the PCM to BIE. Signless integer, value range: 1~6. 6) BIETS (Base station Interface Equipment TS): time slot number of the PCM to BIE . Signless integer, value range: 0~31. 7) BIESUBTS (BIE Sub Ts): sub-time-slot number of the PCM to BIE. Enumerated type, value range: 0, 1, 2, 3, 251, 252, 253, 254, 255. 8) PCMOUT (PCM Out): No. of the PCM from BIE. Signless integer, value range: 1~6. 9) TSOUT (Ts Out): time slot number of the PCM from BIE. Signless integer, value range: 0~31. 10) SUBTSOUT (Sub Ts Out): sub-time-slot number of the PCM from BIE . Signless integer, value range: 0, 1, 2, 3, 251, 252, 253, 254, 255. 1.5.3.39 EDCD 1. Command function To delete DropCom. 2. Syntax structure EDCD: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS, BIESUBTS; 3. Parameter description 1) EBSSID (BSS Identification): connected BSS identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024.

Page 324 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): No. of the PCM to BIE. Signless integer, value range: 1~6. 6) BIETS (Base station Interface Equipment TS): time slot number of the PCM to BIE . Signless integer, value range: 0~31. 7) BIESUBTS (BIE Sub Ts): sub-time-slot number of the PCM to BIE. Enumerated type, value range: 0, 1. 2, 3, 251, 252, 253, 254, 255. 1.5.3.40 EDCQ 1. Command function To view the related attribute of the adjacent site of DropCom. 2. Syntax structure EDCQ: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS, BIESUBTS: PARAGRP; 3. Parameter description 1) EBSSID (BSS Identification): connected BSS identification. Signless integer, value range: 1~255. 2) ESITEID (Site Equipment Identification): site equipment identification of the BSS equipment. Signless integer, value range: 1~1024. 3) ESITENM (Site Equipment Name): site equipment alias. Character string type, the maximum length of the character string is 40.

Page 325 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): No. of the PCM to BIE. Signless integer, value range: 1~6. 6) BIETS (Base station Interface Equipment TS): time slot number of the PCM to BIE . Signless integer, value range: 0~31. 7) BIESUBTS (BIE Sub Ts): sub-time-slot number of the PCM to BIE. Enumerated type, value range: 0, 1. 2, 3, 251, 252, 253, 254, 255. 8) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL. 1.5.3.41 EDPC 1. Command function To create a DropBie PCM. 2. Syntax structure EDPC: EBSSID, {ESITEID, ESITENM}, RACKNO (Rack No): BIEPCM: RELSITE, RELRACK, RELBPCM; 3. Parameter description 1) EBSSID : BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the cha racter string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4.
Page 326 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 6) RELSITE (Related Site Equipment): equipment identification of adjacent site. Signless integer, value range: 1~1024. 7) RELRACK (Related Rack): adjacent rack number. Signless integer, value range: 1~4. 8) RELBPCM (Related aBis PCM): PCM No. of the adjacent B S E1 interface. Signless integer, value range: 1~4. 1.5.3.42 EDPD 1. Command function To delete a DropBie PCM. 2. Syntax structure EDPD: EBSSID, {ESITEID, ESITENM}, RACKNO, BIEPCM; 3. Parameter description 1) EBSSID : BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No. of the BS E1 interface. Signless integer, value range: 1~6.

Page 327 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.43

EDPQ 1. Command function To view the attribute of a DropBie PCM. 2. Syntax structure EDPQ: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM: PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 6) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL.

1.5.3.44

EDSA 1. Command function To modify DSP status attribute. 2. Syntax structure EDSA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO: AD;
Page 328 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range0~20. 6) DSPNO (Dsp No .): DSP number. Signless integer, value range: 1~8. 7) AD (Administer State): administration state. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.45 EDSC 1. Command function To create a DSP under a DRT unit. 2. Syntax structure EDSC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: DSPNO, DSPTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 329 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No.): DSP number. Signless integer, value range: 1~8. 7) DSPTYPE (Dsp Type): DSP type. Signless integer, value range: 1~15. 1.5.3.46 EDSD 1. Command function To delete a DSP under a DRT line. 2. Syntax structure EDSD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.
Page 330 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No.): DSP number. Signless integer, value range: 1~8. 1.5.3.47 EDSQ 1. Command function To view the attribute of a DSP. 2. Syntax structure EDSQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, DSPNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) DSPNO (Dsp No .): DSP number. Signless integer, value range: 1~8. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: STATES, STATIC, the default value is ALL.

Page 331 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.48

EFFA 1. Command function To modify the configuration status attribute of a FRP board. 2. Syntax structure EFFA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): FRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 8 to 16. 7) AD (Administer State): administration state. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking.

1.5.3.49

EFFC 1. Command function To create a FRPCFG.


Page 332 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EFFC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: AUCHW; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): FRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 1~16. 1.5.3.50 EFFD 1. Command function To delete a FRPCFG. 2. Syntax structure EFFD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 333 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): FRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 8 to 16. 1.5.3.51 EFFQ 1. Command function To view the attribute of a FRPCFG. 2. Syntax structure EFFQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, AUCHW: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127.
Page 334 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): FRP unit name. Signless integer, value range: 0~20. 6) AUCHW (Auc Hw.): HW number of the AUC. Signless integer, value range: 1~16. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: STATES, STATIC, the default value is ALL. 1.5.3.52 EFSA 1. Command function To modify the administration state attribute of a remote SMPP board COM. 2. Syntax structure EFSA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, FSMPPTS, FSMPPSTS: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the remote SMPP board. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name of the remote SMPP board. Signless integer, value range: 0~20.

Page 335 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PCMNO (Pcm No.): PCM No. of the remote SMPP board. Signless integer, value range: 1~4. 7) FSMPPTS (Far Smpp Time Slot): time slot number of the remote SMPP board. Signless integer, value range: 0~127. 8) FSMPPSTS (Far Smpp Sub Time Slot): sub-time slot number of the remote SMPP board. Signless integer, value range: 0~255. 9) AD (Administer State): administration state. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.53 EFSC 1. Command function To create the COM of a remote SMPP board. 2. Syntax structure EFSC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, FSMPPTS: FSMPPSTS: FSPPHW1, FSPPTS1: FSPPHW2, FSPPTS2: TNETHW, tNETTS, tNETSTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the remote SMPP board. Signless integer, value range: 2 to 127.
Page 336 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): unit name of the remote SMPP board. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. of the remote SMPP board. Signless integer, value range: 1~4. 7) FSMPPTS (Far Smpp Time Slot): time slot number of the remote SMPP board. Signless integer, value range: 0~127. 8) FSMPPSTS (Far Smpp Sub Time Slot): sub-time slot number of the remote SMPP board. Signless integer, value range: 0~255. 9) FSPPHW1 (FSPP Hw No.1): FSPP HW number 1. Signless integer, value range: 0~16. 10) FSPPTS1 (FSPP Time Slot No.1): FSPP time slot number 1. Signless integer, value range: 0~127. 11) FSPPHW2 (FSPP Hw No.2): FSPP HW number 2. Signless integer, value range: 0~16. 12) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64. 13) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 14) TNETSTS (Tnet Sub Time Slot): T net sub-time slot number. Signless integer, value range: 0~255. 1.5.3.54 EFSD 1. Command function To delete the COM of a remote SMPP board. 2. Syntax structure

Page 337 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EFSD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, FSMPPTS, FSMPPSTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the remote SMPP board. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name of the remote SMPP board. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM number of the remote SMPP. Signless integer, value range: 1~4. 7) FSMPPTS (Far Smpp Time Slot): time slot number of the remote SMPP Signless integer, value range: 0~127. 8) FSMPPSTS (Far Smpp Sub Time Slot): sub-time-slot number of the remote SMPP. Signless integer, value range: 0~255. 1.5.3.55 EFSQ 1. Command function To view the COM status attribute of a remote SMPP board. 2. Syntax structure

Page 338 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EFSQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, FSMPPTS, FSMPPSTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the remote SMPP board. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name of the remote SMPP board. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM number of the remote SMPP. Signless integer, value range: 1~4. 7) FSMPPTS (Far Smpp Time Slot): time slot number of the remote SMPP Signless integer, value range: 0~127. 8) FSMPPSTS (Far Smpp Sub Time Slot): sub-time-slot number of the remote SMPP. Signless integer, value range: 0~255. 9) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, enumerated items: ALL (including dynamic attribute and static attribute), the default value is ALL. 1.5.3.56 EGCA 1. Command function To modify the status attribute of a Gb interface time slot.
Page 339 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EGCA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. Signless integer, value range: 0~127. 8) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state. 1.5.3.57 EGCC 1. Command function To create the COM of a Gb interface time slot. 2. Syntax structure

Page 340 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EGCC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: TS, GIPPHW1, GIPPTS1, GIPPHW2, GIPPTS2; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM number of TIC. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. Signless integer, value range: 0~127. 8) GIPPHW1 (Gipp Hw1): GIPP HW1 number. Signless integer, value range: 1~16. 9) GIPPTS1 (Gipp Ts): GIPP time slot number 1. Signless integer, value range: 0~127. 10) GIPPHW2 (Gipp Hw): GIPP HW2 number. Signless integer, value range: 1~16. 11) 1.5.3.58 EGCD 1. Command function
Page 341 of 591

GIPPTS2 (Gipp Ts ): GIPP time slot number 2.

Operation Manual of ZXG10-BSC (V2)-Vol 2

To dele te the COM of a Gb interface time slot. 2. Syntax structure EGCD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. Signless integer, value range: 0~127. 1.5.3.59 EGCM 1. Command function To modify the COM of a Gb interface time slot. 2. Syntax structure EGCM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: GIPPHW1, GIPPTS1, GIPPHW2, GIPPTS2; 3. Parameter description
Page 342 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): GIU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TIC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM number of TIC. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. Signless integer, value range: 0~127. 8) GIPPHW1 (Gipp Hw1): GIPP HW1 number. Signless integer, value range: 1~16. 9) GIPPTS1 (Gipp Ts): GIPP time slot number 1. Signless integer, value range: 0~127. 10) GIPPHW2 (Gipp Hw): GIPP HW2 number. Signless integer, value range: 1~16. 1.5.3.60 EGCQ 1. Command function To view the COM attribute of a Gb interface time slot. 2. Syntax structure EGCQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS: PARAGRP;
Page 343 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. Signless integer, value range: 0~127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.61 EGPC 1. Command function To create a Gb interface PCM line of a BSC. 2. Syntax structure EGPC : {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 344 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 1.5.3.62 EGPD 1. Command function To delete a Gb interface PCM line of a BSC. 2. Syntax structure EGPD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20.
Page 345 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PCMNO (Pcm No.): PCM No. 1.5.3.63 EGPQ 1. Command function To view the attribute of a Gb interface PCM. 2. Syntax structure EGPQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) PARAGRP (Parameter Group): attribute package type. 1.5.3.64 EGTA 1. Command function To modify the GTRUNK status attribute of a Gb interface time slot.
Page 346 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EGTA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, tS: AD, SPY; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) TS (Ts): BRP unit ? time slot number. Signless integer, value range: 0~127. 7) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 8) SPY ( Administer State): Spy status attribute. 1.5.3.65 EGTC 1. Command function To create a GTRUNK of a Gb interface time slot. 2. Syntax structure EGTC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: TS, DSPNO;
Page 347 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) TS (Ts): BRP unit ? time slot number. Signless integer, value range: 0~127. 7) DSPNO (Dsp No): the DSP number corresponding to the time slot. Signless integer, value range: 1~8. 1.5.3.66 EGTD 1. Command function To delete a GTRUNK of a Gb interface time slot. 2. Syntax structure EGTD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, tS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 348 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): AIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): AIPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 7) TS (Ts): time slot number. 1.5.3.67 EGTM 1. Command function To modify a GTRUNK of a Gb interface time slot. 2. Syntax structure EGTM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, tS: DSPNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127.
Page 349 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) TS (Ts): BRP unit ? time slot number. Signless integer, value range: 0~127. 7) DSPNO (Dsp No): the DSP number corresponding to the time slot. 1.5.3.68 EGTQ 1. Command function To view the GTRUNK attribute of a Gb interface time slot. 2. Syntax structure EGTQ: {EBSCID, PARAGRP; EBSCNAME}, MODULENO, MUNIT, UNIT, tS:

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): SPCU multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BRP unit name. Signless integer, value range: 0~20. 6) TS (Ts): BRP unit ? time slot number. Signless integer, value range: 0~127. 7) PARAGRP (Parameter Group): attribute package type.
Page 350 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.69

EHCA 1. Command function To modify the status attribute of the HDLC channel coding under a MPPP board. 2. Syntax structure EHCA: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 7) AD (Administer State): administration state. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state.

1.5.3.70

EHCC 1. Command function

Page 351 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To create the channel coding of HDLC under a MPPP board. 2. Syntax structure EHCC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): BCH, LINKPORT, WIDTH, MUNIT; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 7) LINKPORT (Link Port): port number. Signless integer, value range: 0~65535. 8) WIDTH (Width): width of control channel. Signless integer, value range: 1~16. 9) MUNIT (Multiple Unit): invalid multi-unit name. 1.5.3.71 EHCD 1. Command function To delete the channel coding of HDLC under a control-layer board.
Page 352 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EHCD: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel No. 1.5.3.72 EHCQ 1. Command function To view the attribute of a HDLC channel under a control-layer board. 2. Syntax structure EHCQ: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 353 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 7) PARAGRP (Parameter Group): attribute package type. 1.5.3.73 EHDA 1. Command function To modify the channel coding of HDLC under a multi-unit. 2. Syntax structure EHDA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BCH: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.
Page 354 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 6) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state. 1.5.3.74 EHDC 1. Command function To create the channel coding of HDLC under a multi-unit. 2. Syntax structure EHDC: {EBSCID, EBSCNAME}, MODULENO, MUNIT: BCH, LINKPORT, WIDTH, CSLOTNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BCH (Base Channel): channel No. Signless i nteger, value range: 0~63. 6) LINKPORT (Link Port): port number. Signless integer, value range: 0~65535. 7) WIDTH (Width): width of control channel. Signless integer, value range: 1~16.
Page 355 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

8) CSLOTNO (Control Slot No.): control layer slot number. Signless integer, the default value is 0. When Munit is the master control unit, CSlotNo=0. 1.5.3.75 EHDD 1. Command function To delete the channel coding of HDLC under a multi-unit. 2. Syntax structure EHDD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BCH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 1.5.3.76 EHDQ 1. Command function To view the channel coding attribute of HDLC under a multi-unit. 2. Syntax structure

Page 356 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EHDQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, BCH: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) BCH (Base Channel): channel No. Signless integer, value range: 0~63. 6) PARAGRP (Parameter Group): attribute package type. 1.5.3.77 EHWA 1. Command function To modify the status attribute of a internal HW. 2. Syntax struc ture EHWA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 357 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit na me. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range: 1~16. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state. 1.5.3.78 EHWC 1. Command function To create an internal HW under a BSC unit. 2. Syntax structure EHWC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: HWNO, HWSET, DELAY; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.
Page 358 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range: 1~16. 7) HWSET (Hw Set): HW setting. Signless integer, value range: 0~65535. 8) DELAY (Delay): HW time delay. 1.5.3.79 EHWD 1. Command function To delete an internal HW under a BSC unit. 2. Syntax structure EHWD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No.

Page 359 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.80

EHWQ 1. Command function To view the attribute of an internal HW. 2. Syntax structure EHWQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. 7) PARAGRP (Parameter Group): attribute package type.

1.5.3.81

ELBA 1. Command function To modify the status attribute of LAPD channel coding. 2. Syntax structure
Page 360 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ELBA: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH, tEI: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel number of the LAPD board. Signless integer, value range: 0~63. 7) TEI (Terminal Equipment Identification): identification. Signless integer, value range: 0~16. terminal equipment

8) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state. 1.5.3.82 ELBC 1. Command function To create LAPD channel coding under a LAPD board. 2. Syntax structure

Page 361 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ELBC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH: TEI, SMODULE: SITEID, BTSID, tRXID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel number of the LAPD board. Signless integer, value range: 0~63. 7) TEI (Terminal Equipment Identification): identification. Signless integer, value range: 0~16. terminal equipment

8) SMODULE: Stored Module. Signless integer, value range: 1~64. 9) SITEID (Site Identification): logic site identification. Signless integer, value range: 0, this value needs to be filled automatically by the radio part. 10) BTSID (Bts Identification): logic cell identification. Signless integer, value range: 0, this value needs to be filled automatically by the radio part. 11) TRXID (Trx Identification): logic transceiver identification.

Page 362 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.83

ELBD 1. Command function To delete the LADP channel coding under a LAPD board. 2. Syntax structure ELBD: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH, tEI; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel number of the LAPD board. Signless integer, value range: 0~63. 7) TEI (Terminal identification. Equipment Identification): terminal equipment

1.5.3.84

ELBQ 1. Command function To view the attribute of LAPD channel coding .

Page 363 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ELBQ: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO, BCH, tEI: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer, value range: 0~27. 6) BCH (Base Channel): channel number of the LAPD board. Signless integer, value range: 0~63. 7) TEI (Terminal identification. Equipment Identification): terminal equipment

8) PARAGRP (Parameter Group): attribute package type. 1.5.3.85 ELTC 1. Command function To create a time slot of a LAPD board. 2. Syntax structure

Page 364 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ELTC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: NEARTS: FARHW, FARTS: TICUNIT, tICPCM, tICTS: RACKNO, SHELFNO, SLOTNO, BCH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16. 7) NEARTS (Near Time Slot): near-end time slot No. Signless integer, value range: 0~127. 8) FARHW (Far Hw): far-end HW number. Signless integer, value range: 1~16. 9) FARTS (Far Time Slot): far-end time slot number. Signless integer, value range: 0~127. 10) 0~20. TICUNIT (Tic Unit): TIC unit name. Signless integer, value range:

11) TICPCM (Tic Pcm): PCM number of TIC. Signless integer, value range: 1~4.

Page 365 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

12) TICTS (Tic Time Slot): TIC time slot number. Signless integer, value range: 0~31. 13) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 14) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 1~6. 15) SLOTNO (Slot No.): slot number of the corresponding LAPD board. Signless integer, value range: 1~27. 16) BCH (Base Channel): channel number of the corresponding LAPD board. 1.5.3.86 ELTD 1. Command function To delete a time slot of a LAPD. 2. Syntax structure ELTD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, NEARTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1.

Page 366 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16. 7) NEARTS (Near Time Slot): near-end time slot No. 1.5.3.87 ELTQ 1. Command function To view the time slot attribute of a LAPD board. 2. Syntax structure ELTQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, NEARTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16.

Page 367 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) NEARTS (Near Time Slot): near-end time slot No. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.88 EMTC 1. Command function To create a time slot of a MPMP board. 2. Syntax structure EMTC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: NEARTS: TNETHW, tNETTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16. 7) NEARTS (Near Time Slot): near-end time slot No. 8) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64.
Page 368 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) TNETTS (Tnet Time Slot): T net time slot number. 1.5.3.89 EMTD 1. Command function To delete a time slot of a MPMP board. 2. Syntax structure EMTD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, NEARTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16. 7) NEARTS (Near Time Slot): near-end time slot No. 1.5.3.90 EMTQ 1. Command function To view the time slot attribute of a MPMP board.
Page 369 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EMTQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, NEARTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BIPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BIPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): near-end HW No. Signless integer, value range: 1~16. 7) NEARTS (Near Time Slot): near-end time slot No. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.91 ENSC 1. Command function To create the COM of a NSPP board. 2. Syntax structure ENSC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: NSMPPTS: NSPPHW, NSPPTS: TNETHW, tNETTS;
Page 370 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): near-end SMPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): near-end SMPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. of the near-end SMPP. Signless integer, value range: 1~4. 7) NSMPPTS (Near Smpp Time Slot): time slot No. of the near-end SMPP.. Signless integer, value range: 0~127. 8) NSPPHW (Nspp Hw): NSPP HW number. Signless integer, value range: 0~16. 9) NSPPTS (Nspp Time Slot): NSPP time slot number. Signless integer, value range: 0~127. 10) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 0~64. 11) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 1.5.3.92 ENSD 1. Command function
Page 371 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To delete the COM of a NSPP board. 2. Syntax structure ENSD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, NSMPPTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): near-end SMPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): near-end SMPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. of the near-end SMPP. Signless integer, value range: 1~4. 7) NSMPPTS (Near Smpp Time Slot): time slot No. of the near-end SMPP.. Signless integer, value range: 0~127. 1.5.3.93 ENSQ 1. Command function To view the COM attribute of a NSPP board. 2. Syntax structure

Page 372 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ENSQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, NSMPPTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): near-end SMPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): near-end SMPP unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. of the near-end SMPP. Signless integer, value range: 1~4. 7) NSMPPTS (Near Smpp Time Slot): time slot No. of the near-end SMPP.. Signless integer, value range: 0~127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.94 ENVA 1. Command function To modify the status attribute of a NSVC of a Gb interface. 2. Syntax structure ENVA: {EBSCID, EBSCNAME}, NSVCI: AD;
Page 373 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) NSVCI (NSVC Id): identification number of NS-VC. Signless integer. 5) AD (Administer State): administration state attribute.. Enumerated type, the enumerated items include: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.95 ENVC 1. Command function To create a NSVC of a Gb interface. 2. Syntax structure ENVC: {EBSCID, EBSCNAME}: NSVCI, NSEI, DLCI, GIUMUNIT, tUNIT, tSUNIT, CIR, BC, BE, tC; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) NSVCI (NSVC Id): identification number of NS-VC. Signless integer.

Page 374 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) NSEI (NSE Id .): identification number of NSE (for check). Signless integer. 5) DLCI (DLC Id): the corresponding DLCI value (10bit). Signless integer. 6) GIUMUNIT (GIU MUNIT): GIU multi-unit name. Signless integer, value range: 1~127. 7) TUNIT (TIC UNIT): TIC unit. Signless integer. 8) TSUNIT (TS UNIT): 2M PCM line of TIC . Signless integer. 9) CIR (CIR): committed rate (k/s). Signless integer. 10) 11) BC (BC): committed burst packet size (k). Signless integer. BE (BE): burst packet beyond size. Signless integer.

12) TC (TC): agreed network detection time (Bc/ CIR). Signless integer. 1.5.3.96 ENVD 1. Command function To delete a NSVC of a Gb interface. 2. Syntax structure ENVD: {EBSCID, EBSCNAME}, NSVCI; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 375 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) NSVCI (NSVC Id): identification number of NS-VC. Signless integer. 1.5.3.97 ENVM 1. Command function To modify a NSVC of a Gb interface. 2. Syntax structure ENVM: {EBSCID, EBSCNAME}, NSEI, NSVCI: DLCI, GIUMUNIT, tUNIT, tSUNIT, CIR, BC, BE, tC; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) NSEI (NSE Id .): identification number of NSE (for check). Signless integer. 4) NSVCI (NSVC Id): identification number of NS-VC. Signless integer. 5) DLCI (DLC Id): the corresponding DLCI value (10bit). Signless integer. 6) GIUMUNIT (GIU MUNIT): GIU multi-unit name. Signless integer, value range: 1~127. 7) TUNIT (TIC UNIT): TIC unit. Signless integer. 8) TSUNIT (TS UNIT): 2M PCM line of TIC. Signless integer. 9) CIR (CIR): committed rate (k/s). Signless integer. 10) BC (BC): committed burst packet size (k). Signless integer.
Page 376 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

11) 12) 1.5.3.98 ENVQ

BE (BE): burst packet beyond size. Signless integer. TC (TC): agreed network detection time (Bc/ CIR).

1. Command function To view the NSVC attribute of a Gb interface. 2. Syntax structure ENVQ: {EBSCID, EBSCNAME}, NSVCI: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) NSVCI (NSVC Id): identification number of NS-VC. Signless integer. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.99 ENWA 1. Command function To modify the status attribute of an internal HW. 2. Syntax structure ENWA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: AD; 3. Parameter description
Page 377 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range1~64. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.100 ENWC 1. Command function To create a T net HW under a BSC unit. 2. Syntax structure ENWC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: HWNO, HWSET, DELAY; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 378 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range: 1~64. 7) HWSET (Hw Set): HW setting. Signless integer, value range: 0~65535. 8) DELAY (Delay): HW time delay. Signless integer, value range: 0~255. 1.5.3.101 ENWD 1. Command function To delete a T net HW under a BSC unit. 2. Syntax structure NWD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2.

Page 379 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range: 1~64. 1.5.3.102 ENWQ 1. Command function To view the HW attribute of a T net. 2. Syntax structure ENWQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): HW No. Signless integer, value range: 1~64. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STA TES, STATIC, the default value is ALL.

Page 380 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.103 EPAA 1. Command function To modify the status attribute of an A interface PCM. 2. Syntax structure EPAA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.104 EPAC 1. Command function To create an A interface PCM line of a BSC.

Page 381 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EPAC: {EBSCID, EBSCNAME, MODULENO}, MUNIT, UNIT: PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No .): PCM No. Signless integer, value range: 1~4. 1.5.3.105 EPAD 1. Command function To delete an A interface PCM line of a BSC. 2. Syntax structure EPAD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 382 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 1.5.3.106 EPAQ 1. Command function To view the attribute of an A interface PCM. 2. Syntax structure EPAQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2.

Page 383 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, STATIC, the default value is ALL. 1.5.3.107 EPBA 1. Command function To modify the status attribute of an ABIS interface PCM. 2. Syntax structure EPBA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking.
Page 384 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.108 EPBC 1. Command function To create a PCM connection relation between both ends of an ABIS interface of a BSC. 2. Syntax structure EPBC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: PCMNO, ESITEID, RACKNO, BIEPCM: RMODULE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 7) ESITEID (Physical Site Identification): identification number of the connected physical site. Signless integer, value range: 1~1024. 8) RACKNO (Rack No.): rack number of the connected site. Signless integer, value range: 1~4. 9) BIEPCM (Base Station Interface Equipment Pcm): connected PCM number. Signless integer, value range: 1~4.
Page 385 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

10) RMODULE (Radio Module): connected radio module number. Signless integer, value range: 1~64. 1.5.3.109 EPBD 1. Command function To delete the BPCM under an ABIS interface PCM. 2. Syntax structure EPBD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 1.5.3.110 EPBQ 1. Command function To view the attribute of an ABIS interface PCM. 2. Syntax structure
Page 386 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EPBQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name of the T net. Signless integer, the default value is 2. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include: ALL, STATES, STATIC, the default value is ALL. 1.5.3.111 EPCC 1. Command function To create a PC2M link. 2. Syntax structure EPCC: {EBSCID, EBSCNAME}: LINK: CSLOTNO, BCH: TRKMUNIT, tRKUNIT, tRKPCM, tRKTS; 3. Parameter description

Page 387 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) LINK (Link): link number. Signless integer, value range: 0~63. 4) CSLOTNO (Slot No.): slot number. Signless integer, value range: 1~27. 5) BCH (Base Channel): channel identification number. Signless integer, value range: 0~63. 6) TRKMUNIT (Trunk Multiple Unit): multi-unit name of the circuit. Signless integer, value range: 2 to 127. 7) TRKUNIT (Trunk Unit): unit name of the circuit. Signless integer, value range: 0~20. 8) TRKPCM (Trunk Pcm): PCM number of the circuit. Signless integer, value range: 1~4. 9) TRKTS (Trunk Time Slot): time slot number of the circuit. Signless integer, value range: 0~31. 1.5.3.112 EPCD 1. Command function To delete a PC2M link. 2. Syntax structure EPCD: {EBSCID, EBSCNAME}: LINK; 3. Parameter description

Page 388 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) LINK (Link): link number. Signless integer, value range: 0~63. 1.5.3.113 EPCQ 1. Command function To view the attribute of a PC2M link. 2. Syntax structure EPCQ: {EBSCID, EBSCNAME}: LINK: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Characte r string type, the maximum length of the character string is 40. 3) LINK (Link): link number. Signless integer, value range: 0~63. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, the default value is ALL. 1.5.3.114 EPEC 1. Command function To create a PECM environment monitoring time slot. 2. Syntax structure
Page 389 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EPEC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PECMTS: TNETHW, tNETTS, tNETSTS: ESITEID; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): PECM multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): PECM unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PECM ? PCM No. Signless integer, value range: 1~4. 7) PECMTS (Pecm Time Slot): PECM time slot number. Signless integer, value range: 0~127. 8) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64. 9) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 10) TNETSTS (Tnet Sub Time Slot): T net sub-time slot number. Signless integer, value range: 0~255. 11) ESITEID (Physical Site Identification): physical site identification. Signless integer, value range: 0~1024.

Page 390 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.115 EPED 1. Command function To delete a PECM environment monitoring time slot. 2. Syntax structure EPED: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, PECMTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): PECM multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): PECM unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PECM ? PCM No. Signless integer, value range: 1~4. 7) PECMTS (Pecm Time Slot): PECM time slot number. 1.5.3.116 EPEQ 1. Command function To view the attribute of a PECM environment monitoring time slot.

Page 391 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EPEQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO, PECMTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): PECM multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): PECM unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PECM ? PCM No. Signless integer, value range: 1~4. 7) PECMTS (Pecm Time Slot): PECM time slot number. 1.5.3.117 EPIA 1. Command function To modify the status attribute of an ABIS interface PCM. 2. Syntax structure EPIA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: AD; 3. Parameter description

Page 392 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.118 EPIC 1. Command function To create an ABIS interface PCM line of a BSC. 2. Syntax structure EPIC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 393 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 1.5.3.119 EPID 1. Command function To delete an ABIS interface PCM line of a BSC. 2. Syntax structure EPID: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4.

Page 394 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.120 EPIQ 1. Command function To view the attribute of an ABIS interface PCM. 2. Syntax structure EPIQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, STATIC, the default value is ALL. 1.5.3.121 EPOC 1. Command function To create a circuit pool.

Page 395 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EPOC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: TCPPTS: DRTUNIT, DSPNO: TNNETHW, tNETTS, tNETSTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): TCPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TCPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): TCPP HW No. Signless integer, value range: 1~9. 7) TCPPTS (Tcpp Time Slot): TCPP time slot number. Signless integer, value range: 0~127. 8) DRTUNIT (DRT Unit): DRT unit name. Signless integer, value range: 0~20. 9) DSPNO (Dsp No.): DSP number. Signless integer, value range: 0~8. 10) TNETHW (Tnet Hw): T net HW number. Signless integer, value range: 1~64. 11) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127.

Page 396 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

12) TNETSTS (Tnet Sub Time Slot): T net sub-time slot number. Signless integer, value range: 0~255. 1.5.3.122 EPOD 1. Command function To delete a circuit pool. 2. Syntax structure EPOD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, tCPPTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): TCPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TCPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): TCPP HW No. Signless integer, value range: 1~9. 7) TCPPTS (Tcpp Time Slot): TCPP time slot number. Signless integer, value range: 0~127. 1.5.3.123 EPOQ 1. Command function
Page 397 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To view the attribute of a circuit pool. 2. Syntax structure EPOQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, tCPPTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): TCPP multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): TCPP unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): TCPP HW No. Signless integer, value range: 1~9. 7) TCPPTS (Tcpp Time Slot): TCPP time slot number. Signless integer, value range: 0~127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.124 EPRC 1. Command function To create an inter-module communication. 2. Syntax structure
Page 398 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

EPRC: {EBSCID, EBSCNAME}, MODULENO: CMODULE, CSLOTNO, BCH, WIDTH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) CMODULE (Comm Module No.): communication module number. Signless integer, value range: 1~64. 5) CSLOTNO (Comm Slot No.): MP slot number. Signless integer, value range: 1~27. 6) BCH (Base Channel): communication channel number. Signless integer, value range: 0~63. 7) WIDTH (Width): width of the communication channel. Signless integer, value range: 0~31. 1.5.3.125 EPRD 1. Command function To delete an inter-module communication. 2. Syntax structure EPRD: {EBSCID, EBSCNAME}, MODULENO, CMODULE; 3. Parameter description

Page 399 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) CMODULE (Comm Module No.): communication module number. Signless integer, value range: 1~64. 1.5.3.126 EPRQ 1. Command function To view the attribute of an inter-module communication. 2. Syntax structure EPRQ: {EBSCID, EBSCNAME}, MODULENO, CMODULE: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) CMODULE (Comm Module No.): communication module number. Signless integer, value range: 1~64. 5) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, the default value is ALL.
Page 400 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.127 EPSA 1. Command function To modify the PCM attribute of a SMPP board. 2. Syntax structure EPSA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0 to 20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.128 EPSC 1. Command function To create a PCM inside BSC (PCM of ABIS interface).

Page 401 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EPSC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0 to 20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 1.5.3.129 EPSD 1. Command function To delete a PCM inside BSC. 2. Syntax structure EPSD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 402 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0 to 20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 1.5.3.130 EPSQ 1. Command function To view the PCM attribute of a SMPP board. 2. Syntax structure EPSQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCMNO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.

Page 403 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0 to 20. 6) PCMNO (Pcm No.): PCM No. Signless integer, value range: 1~4. 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, the default value is ALL. 1.5.3.131 ESBA 1. Command function To modify the attribute of a BSC board. 2. Syntax structure ESBA: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): BTYPE: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) SLOTNO (Slot No.): BSC board slot number. Signless integer, value range: 0~27. 6) BTYPE (Board Type): BSC board type. Enumerated type, enumerated items: DTI, DSN, CKI, DSNI, SYCK, PWRB, SMB, SMT1, SMT2, DSN2B,

Page 404 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

AIPP, BIPP, tCPP, NSPP, FSPP, ATIC, BTIC, INTERNALTIC, PWRP, COMI, DRT20, EDRT20, PUC, GTIC, GIPP, BRP, FRP, HMS. 7) AD (Administer State): administration state attribute.. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.132 ESBC 1. Command function To create a board under an object (EBSCID, RACKNO, SHELFNO). 2. Syntax structure Mode 1: general boards. ESBC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO (Shelf No): SLOTNO, BTYPE: MUNIT, UNIT; Mode 2: control layer boards. ESBC: {EBSCID, EBSCNAME}, RACKNO, SHELFNO (Shelf No): SLOTNO, BTYPE: SMODULE, COMMTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer value, value range: from 1 to 16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer value, value range: from 0 to 6.
Page 405 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) SLOTNO (Slot No.): BSC slot No. Signless integer value, when SHELFNO=0, value range is 0~27, when SHELFNO is greater than or equal to 1, value range is 1~27. 6) BTYPE (Board Type): BSC non-control layer and control layer board type. Mode 1, non-control layer boards, enumerated type, enumerated items: DTI, DSN, CKI, DSNI, SYCK, PWRB, SMB, SMT1, SMT2, DSN2B, AIPP, BIPP, tCPP, NSPP, FSPP, ATIC, BTIC, INTERNALTIC, COM1, DRT20, EDRT20, PWRP, PUC, GTIC, BRP, FRP, GIPP, HMS. Mode 2, control layer boards, enumerated type, enumerated items: MP, SMEM, MONI, PEPD, MPPP, MTP, LAPD, MPMP. 7) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer value, value range: from 2 to 127. 8) UNIT (Unit): BSC unit name. Signless integer value, value range: from 0 to 16. 9) SMODULE (Stored Module): module number. Signless integer value, value range: from 1 to 64. 10) COMMTYPE ( Communication Type): board type. Enumerated type, the enumerated items include: MONI, PEPD, MPPP_26, MPPP_58, MPPP_32, MPPP_64, MTP, MTP16, LAPD, LAPD64, MPMP, MPMP64, NONE. 1.5.3.133 ESBD 1. Command function To delete a BSC board. 2. Syntax structure ESBD: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): BTYPE; 3. Parameter description
Page 406 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer value, value range: from 1 to 16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer value, value range: from 0 to 6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer value, when SHELFNO=0, value range is 0~27; when SHELFNO is greater than or equal to 1, value range is 1~27. 6) BTYPE (Board Type): BSC board type. Enumerated type, enumerated items: DTI, DSN, CKI, DSNI, SYCK, PWRB, SMB, SMT1, SMT2, DSN2B, AIPP, BIPP, tCPP, NSPP, FSPP, ATIC, BTIC, INTERNALTIC, COM1, DRT20, EDRT20, MP, SMEM, LAPD, MPMP, PEPD, MTP, PWRP, PUC, GIPP, BRP, FRP, GTIC, HMS. 1.5.3.134 ESBQ 1. Command function To view the attribute of a BSC board. 2. Syntax structure ESBQ: {EBSCID, EBSCNAME}, RACKNO, SHELFNO, SLOTNO (Slot No): BTYPE: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 407 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer value, value range: from 1 to 16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer value, value range: from 0 to 6. 5) SLOTNO (Slot No.): BSC slot No. Signless integer value, when SHELFNO=0, value range is 0~27, when SHELFNO is greater than or equal to 1, value range is 1~27. 6) BTYPE (Board Type): BSC board type. Enumerated type, enumerated items: DTI, DSN, CKI, DSNI, SYCK, PWRB, SMB, SMT1, SMT2, DSN2B, AIPP, BIPP, tCPP, NSPP, FSPP, ATIC, BTIC, INTERNALTIC, COM1, DRT20, EDRT20, MP, SMEM, LAPD, MPMP, PEPD, MTP, PWRP, PUC, GIPP, BRP, FRP, GTIC, HMS. 1.5.3.135 ESEC 1. Command function To create an NSE entity of Gb interface. 2. Syntax structure ESEC: {EBSCID, EBSCNAME}, NSEI; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) NSEI (NSE Id.): NSE entity number. Signless integer.
Page 408 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.136 ESED 1. Command function To delete an NSE entity of Gb interface. 2. Syntax structure ESED: {EBSCID, EBSCNAME}, NSEI; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) NSEI (NSE Id.): NSE entity number. Signless integer. 1.5.3.137 ESEQ 1. Command function To view an NSE entity of Gb interface. 2. Syntax structure ESEQ: {EBSCID, EBSCNAME}, NSEI: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 409 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) NSEI (NSE Id.): NSE entity number. Signless integer. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.138 ESIC 1. Command function To create a set of site equipment. 2. Syntax structure ESIC: EBSSID: ESITEID, SITETYPE, ALIAS: L, B: OAMID, SYNSRC: MODULENO; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) SITETYPE (Site Equipment Type): site equipment type. Signless integer, value range: 1~7. Among them, 1: v1.0 indoor; 2: v1.2 indoor; 3: v1.0 micro-cell; 4: v1.2 outdoor; 5: v2.0 indoor; 6: v2.0 outdoor; 7: v2.1outdoor (B2 miniaturized base station). 4) ALIAS: Site Equipment Name. Character string type, the maximum length of the character string is 40. 5) L (Longitude): longitude coordinate of site equipment location. Floatingpoint type, value range: -180 to 180, to the accuracy of 2 digits after the decimal point, the default value is 0. 6) B (Latitude): latitude coordinate of site equipment location. Real number type, value range: -90 to 90, to the accuracy of 2 digits after the decimal point, the default value is 0.
Page 410 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) OAMID (OAM Identification): OAM identification (OMU identification). Signless integer, value range: 0~4, the default value is 1. 8) SYNSRC (SynSource): synchronization mode with BSC. Signless integer, value range: 0~2, the default value is 0. Among them, 0: internal clock; 1: PCM clock of the Abis interface (network clock); 2. other clock sources. 9) MODULENO (Module No.): peripheral module number of the site. Signless integer, value range: 2 to 8. 1.5.3.139 ESID 1. Command function To delete a set of site equipment. 2. Syntax structure ESID: EBSSID, { ESITEID, ESITENM }; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 1.5.3.140 ESIM 1. Command function To modify the attribute of site equipment. 2. Syntax structure
Page 411 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ESIM: EBSSID {, ESITEID, ESITENM }: ALIAS, L, B, OAMID, SYNSRC; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) ALIAS: Site Equipment Name. Character string type, the maximum length of the character string is 40. 5) L (Longitude): longitude coordinate of site equipment location. Floatingpoint type, value range: -180 to 180, to the accuracy of 2 digits after the decimal point. 6) B (Latitude): latitude coordinate of site equipment location. Floatingpoint type, value range: -90 to 90, to the accuracy of 2 digits after the decimal point. 7) OAMID (OAM Identification): OAM identification (OMU identification). Signless integer value, value range: 0~4. 8) SYNSRC (SynSource): synchronization mode with BSC. Signless integer value, value range: 0~2. Among them, 0: internal clock; 1: PCM clock of the Abis interface (network clock); 2. other clock sources. 1.5.3.141 ESIQ 1. Command function To view the attribute of site equipment. 2. Syntax structure

Page 412 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ESIQ: EBSSID, {ESITEID, ESITENM }: PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL, the default value is ALL. 1.5.3.142 ESMA 1. Command function To modify the status attribute of a BSC multi-unit. 2. Syntax structure ESMA: {EBSCID, EBSCNAME}, MODULENO, MUNIT: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.
Page 413 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) AD (Administer State): state administration. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.143 ESMC 1. Command function To create a multi-unit under MODULE (MODULENO = 1). 2. Syntax structure ESMC: {EBSCID, SMODULE; EBSCNAME}, MODULENO: MUNIT, MUTYPE,

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) MUTYPE (Multiple Unit Type): BSC multi-unit type. Enumerated type, enumerated items: TC1, tC2, AIE 2, BIE1, BIE2, SM, NSB, NSM, FSB, FSM, DSN, DSNI, PWR, SYCK. 6) SMODULE (Stored Module): stored module. Signless integer, value range: 1~64.

Page 414 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.144 ESMD 1. Command function To delete a multi-unit under MODULE (MODULENO = 1). 2. Syntax structure ESMD: {EBSCID, EBSCNAME}, MODULENO, MUNIT; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 1.5.3.145 ESMQ 1. Command function To view the attribute of a multi-unit under MODULE (MODULENO = 1). 2. Syntax structure ESMQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.
Page 415 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, STATIC, the default value is ALL. 1.5.3.146 ESOC 1. Command function To create a module. 2. Syntax structure ESOC: {EBSCID, EBSCNAME}: MODULENO, MTYPE: FILEID, FILEVER; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MTYPE (Module Type): BSC module type. Signless integer, value range: 1 or 2, among them MType=1 represents central module; MType=2 represents peripheral module .

Page 416 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) FILEID (File Identification): MP software identification. Enumerated type, enumerated items: BSC_MP. 6) FILEVER (File Version): MP software version. Character string type, the maximum length of the character string is 12. 1.5.3.147 ESOD 1. Command function To delete a module. 2. Syntax structure ESOD: {EBSCID, EBSCNAME}, MODULENO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 1.5.3.148 ESOF 1. Command function To acquire the foreground MP clock. 2. Syntax structure ESOF: {EBSCID, EBSCNAME}, ModuleNo; 3. Parameter description
Page 417 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 1.5.3.149 ESOQ 1. Command function To view the attribute of a BSC module. 2. Syntax structure ESOQ: {EBSCID, EBSCNAME}, MODULENO: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, STATIC, the default value is ALL. 1.5.3.150 ESOS 1. Command function To set the foreground MP clock with the OMCR clock as the reference.
Page 418 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure ESOS: {EBSCID, EBSCNAME}, ModuleNo: OmcrDate, OmcrTime; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) OmcrDate (Omcr Date.): OMCR date (YYYY-MM-DD). Date integer type. 5) OmcrTime (Omcr Time.): second-order time of OMCR (HH-MM-SS). Type integer type. 1.5.3.151 ESOY 1. Command function To synchronize state after recovery from link disconnection of a BSC module. 2. Syntax structure ESOY: {EBSCID, EBSCNAME}, ModuleNo; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255.

Page 419 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 1.5.3.152 ESRC 1. Command function This command is used to create a rack under object EBSCID. 2. Syntax structure ESRC: {EBSCID, EBSCNAME}: RACKNO, RACKTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) RACKTYPE (Rack Type): BSC rack type. Signless integer, the default value of the parameter is 1. The value range is only 1. 1.5.3.153 ESRD 1. Command function To delete a rack of a BSC. 2. Syntax structure

Page 420 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

ESRD: {EBSCID, EBSCNAME}, RACKNO; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 1.5.3.154 ESRQ 1. Command function To view the configuration of shelves and boards in object (EBSCID, RACKNO). 2. Syntax structure ESRQ: {EBSCID, EBSCNAME}, RACKNO (Rack No): PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL.
Page 421 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.155 ESSC 1. Command function To create a shelf under object (EBSCID, RACKNO). 2. Syntax structure ESSC: {EBSCID, EBSCNAME}, RACKNO (Rack No): SHELFNO, STYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) STYPE (Shelf Type.): BSC shelf type. Signless integer, value range: enumerated type. Among them, : 0: NULL (used for the creation of PWRP) ; 1: BNET; 2: BCTL; 3: BIE; 4: SM; 5: TC; 6: BSM; 7: BATC; 8: BIF; 9: SPCU; 10: GIU. 1.5.3.156 ESSD 1. Command function To delete a shelf under object (EBSCID, RACKNO). 2. Syntax structure ESSD: {EBSCID, EBSCNAME}, RACKNO, SHELFNO;
Page 422 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16. 4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 1.5.3.157 ESSQ 1. Command function To view the shelf type and board configuration in object (EBSCID, RACKNO, SHELFNO). 2. Syntax structure ESSQ: {EBSCID, EBSCNAME}, RACKNO, SHELFNO (Shelf No): PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) RACKNO (Rack No.): BSC rack No. Signless integer, value range: 1~16.

Page 423 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) SHELFNO (Shelf No.): BSC shelf No. Signless integer, value range: 0~6. 5) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.158 ESUA 1. Command function To modify BSC unit ? status attribute. 2. Syntax structure ESUA: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: UTYPE: AD; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) UTYPE (Unit Type): BSC unit type. Enumerated type, enumerated items: DRT, DTI, SMT1, SMT2, BIE, DSN, DSNI, PWRB, CKI, SYCK, PECM, tCPP, AIPP, BIPP, NSPP, FS, PP, EDRT, BOSN, COMI, INTERNALTIC, EXTERNALTIC, PWRP, PUC, GTIC, GIPP, BRP, FRP, HMS, L239FRP .
Page 424 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) AD (Administer State): administration state. Enumerated type, enumerated items: L, U, S. Among them, L: locking state; U: unlocking state; S: time delay blocking. 1.5.3.159 ESUC 1. Command function To create a unit under a multi-unit. 2. Syntax structure Mode 1: ESUC: {EBSCID, EBSCNAME}, MODULENO, MUNIT: UNIT, UTYPE: HWSET, CONTYPE, CONSYCK; Mode 2: ESUC: {EBSCID, EBSCNAME}, MODULENO, MUNIT: UNIT, UTYPE: HWSET, CONTYPE, CONSYCK: CONMUNIT, CONUNIT; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20.

Page 425 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) UTYPE (Unit Type): BSC unit type. Mode 1, enumerated type, enumerated items: DRT, DTI, SMT1, EXTERNALTIC, BIE, DSN, DSNI, PWRB, CKI, SYCK, PECM, tCPP, AIPP, BIPP, NSPP, FSPP, EDRT, BOSN, COMI, PWRP, PUC, GTIC, GIPP, BRP, FRP, HMS, L200FRP. Mode 2, enumerated type, enumerated items: SMT2, INTERNALTIC . 7) HWSET (Hw Set): HW setting. Signless integer, value range: 0~65535. 8) CONTYPE (Connect Type): interconnection type (PCM, HW). Signless integer, the default value is 1. 0 represents HW, 1 represents PCM. 9) CONSYCK (Connect Syck): whether to connect the clock. Signless integer, the default value is 1. 0 represents not to connect the clock, 1 represents to connect the clock. 10) CONMUNIT (Connect Multiple Unit): name of the connected multi-unit. Signless integer, value range: 1~127. 11) CONUNIT (Connect Unit): name of the connected unit. Signless integer, value range: 0~16. 1.5.3.160 ESUD 1. Command function To delete a unit under a BSC multi-unit. 2. Syntax struc ture ESUD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: UTYPE; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.
Page 426 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) UTYPE (Unit Type): BSC unit type. Enumerated type, enumerated items: DRT, DTI, SMT1, SMT2, BIE, DSN, DSNI, PWRB, CKI, SYCK, PECM, tCPP, AIPP, BIPP, NSPP, FSPP, EDRT, BOSN, COMI, INTERNALTIC, EXTERNALTIC, PWRP, PUC, GTIC, GIPP, BRP, FRP, HMS, L239FRP . 1.5.3.161 ESUQ 1. Command function To view the attribute of a BSC unit. 2. Syntax structure ESUQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT: UTYPE: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): BSC multi-unit name. Signless integer, value range: 2 to 127.
Page 427 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) UTYPE (Unit Type): BSC unit type. Enumerated type, enumerated items: DRT, DTI, SMT1, SMT2, BIE, DSN, DSNI, PWRB, CKI, SYCK, PECM, tCPP, AIPP, BIPP, NSPP, FSPP, EDRT, BOSN, COMI, INTERNALTIC, EXTERNALTIC, PWRP, PUC, GTIC, GIPP, BRP, FRP, HMS, L239FRP . 7) PARAGRP (Parameter Group): attribute package type. Enumerated type, enumerated items: ALL, STATES, STATIC, the default value is ALL. 1.5.3.162 ETCC 1. Command function To create a time slot COM. 2. Syntax structure ETCC: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO: TNETTS: COMMHW, COMMTS: CSLOTNO, BCH; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20.

Page 428 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) HWNO (Hw No.): T net HW number of the connected single network. Signless integer, value range: 1~64. 7) TNETTS (T net Time Slot): T net time slot number. Signless integer, value range: 0~127. 8) COMMHW (Comm Hw): HW of the connected communication board. Signless integer, value range: 1~64. 9) COMMTS (Comm Time Slot): time slot number of the connected communication board. Signless integer, value range: 0~127. 10) CSLOTNO (Comm Slot No.): slot number of the control layer board. Signless integer, value range: 0~27. 11) BCH (Base Channel): channel of the control board. Signless integer, value range: 0~63. 1.5.3.163 ETCD 1. Command function To delete a time slot COM. 2. Syntax structure ETCD: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, tNETTS; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40.

Page 429 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127. 5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): T net HW number of the connected single network Signless integer, value range: 1~64. 7) TNETTS (T net Time Slot): T net time slot number. Signless integer, value range: 0~127. 1.5.3.164 ETCQ 1. Command function To view the attribute of a time slot COM. 2. Syntax structure ETCQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, HWNO, tNETTS: PARAGRP; 3. Parameter description 1) EBSCID (BSC Equipment Identification): BSC identification No. Signless integer, value range: 1~255. 2) EBSCNAME (BSC Equipment Name): BSC name. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): BSC module No. Signless integer, the default value is 1. 4) MUNIT (Multiple Unit): multi-unit name. Signless integer, value range: 2 to 127.
Page 430 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): BSC unit name. Signless integer, value range: 0~20. 6) HWNO (Hw No.): T net HW number of the connected single network. Signless integer, value range: 1~64. 7) TNETTS (Tnet Time Slot): T net time slot number. Signless integer, value range: 0~127. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, the enumerated items include ALL, the default value is ALL. 1.5.3.165 ETPC 1. Command function To create a panel under site equipment. 2. Syntax structure ETPC: EBSSID, {ESITEID, ESITENM}, RACKNO, SHELFNO (Shelf No): PANELNO, PTYPE; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): r ack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5.

Page 431 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

6) PANELNO (Panel No.): panel number. Signless integer, value range: 1~16. 7) PTYPE (Panel Type): panel type. Enumerated type, value range: OMU, BIE, CKU, CKD, PSA, PSB, PA, tRU, MUL, HYCOM, EBIE, EOMU, SDU, MBPWR, MBTRX, EAM, MBSCU, ETDC, PSU1, PSU2, ACCU, PILE, tM, PDM, CMM, tRM, CDU, CEU, RDU, STRU, SPAU. 1.5.3.166 ETPD 1. Command function To delete a panel under site equipment. 2. Syntax structure ETPD: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO: PTYPE; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) PANELNO (Panel No.): panel number. Signless integer, value range: 1~16.

Page 432 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) PTYPE (Panel Type): panel type. Enumerated type, value range: OMU, BIE, CKU, CKD, PSA, PSB, PA, tRU, MUL, HYCOM, EBIE, EOMU, SDU, MBPWR, MBTRX, EAM, MBSCU, ETDC, PSU1, PSU2, ACCU, PILE, tM, PDM, CMM, tRM, CDU, CEU, RDU, STRU, SPAU. 1.5.3.167 ETPQ 1. Command function To view the attribute of a panel under site equipment: static attribute or dynamic attribute. 2. Syntax structure ETPQ: EBSSID, {ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO: PTYPE, PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) PANELNO (Panel No.): panel number. Signless integer, value range: 1~16. 7) PTYPE (Panel Type): panel type. Enumerated type, value range: OMU, BIE, CKU, CKD, PSA, PSB, PA, tRU, MUL, HYCOM, EBIE, EOMU, SDU,
Page 433 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

MBPWR, MBTRX, EAM, MBSCU, ETDC, PSU1, PSU2, ACCU, PILE, tM, PDM, CMM, tRM, CDU, CEU, RDU. 8) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL, STATES. Among them, ALL: viewing static attribute; STATES: viewing dynamic attribute. 1.5.3.168 ETRC 1. Command function To create a rack under site equipment. 2. Syntax structure ETRC: EBSSID {, ESITEID, ESITENM}: RACKNO, RACKTYPE: CMMNO, CKUDELAY; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) RACKTYPE (Rack Type): rack type. Signless integer, value range: 1~7. Among them, 1: v1.0 indoor; 2: v1.2 indoor; 3: v1.0 micro-cell; 4: v1.2 outdoor; 5: v2.0 indoor; 6: v2.0 outdoor; 7: v2.1 indoor; 6) CMMNO (CMM No): public layer number (an attribute added for BTS 2.0). Signless integer, value range: 0~4, the default value is 0 (representing insignificance).
Page 434 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) CKUDELAY (CKU Delay): time delay parameter. Signless integer, value range: 0~7, the default value is 0. 1.5.3.169 ETRD 1. Command function To delete a rack under site equipment. 2. Syntax structure ETRD: EBSSID {, ESITEID, ESITENM}, RACKNO; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 1.5.3.170 ETRM 1. Command function To modify the attribute of a rack under site equipment. 2. Syntax structure ETRM: EBSSID {, ESITEID, ESITENM}, RACKNO (Rack No): CMMNO, CKUDELAY; 3. Parameter description
Page 435 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) CMMNO (CMM No): public layer number (an attribute added for BTS 2.0). Signless integer, value range: 0~4. 6) CKUDELAY (CKU Delay): time delay parameter. Signless integer, value range: 0~7. 1.5.3.171 ETRQ 1. Command function To view the attribute of a rack under site equipment. 2. Syntax structure ETRQ: EBSSID, { ESITE ID, ESITENM}, RACKNO (Rack No): PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40.

Page 436 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL. 1.5.3.172 ETSC 1. Command function To create a shelf under site equipment. 2. Syntax structure ETSC: EBSSID, {ESITEID, ESITENM}, RACKNO (Rack No): SHELFNO, STYPE; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) STYPE (Shelf Type): shelf type. Signless integer, value range: 1~7. Among them, 1: v1.X public shelf; 2: v1.X transceiver shelf; 3: v1.0 microcell shelf; 4: v2.0 public shelf; 5: v2.0 transceiver shelf; 6: v2.0 outdoor shelf; 7: v2.1 indoor shelf (B2 miniaturized base station).

Page 437 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.173 ETSD 1. Command function To delete a shelf under site equipment. 2. Syntax structure ETSD: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 1.5.3.174 ETSQ 1. Command function To view the type of a shelf under site equipment. 2. Syntax structure ETSQ: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO; 3. Parameter description

Page 438 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 1.5.3.175 ETXC 1. Command function To create a connecting relation between TRU panel and HYCOM/MUL panel: TRUMulHyc MO. 2. Syntax structure ETXC: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO: PORTTYPE, LEVELNUM: L1RACK, L1SHELF, L1PANEL: L2RACK, L2SHELF, L2PANEL; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40.

Page 439 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) PANELNO ( Panel No.): panel number of the TRU. Signless integer, value range: 1~16. 7) PORTTYPE (Port Type): type of the port for connecting the transceiver module and AEM (TX, RX, RXD), i.e., connecting mode. Enumerated type, value range: 1, 2, 4. Among them, 1: TX (HYCOM) ; 2: RX (MUL) ; 4: RXD. 8) LEVELNUM (Level Number): level number for connecting with AEM. Signless integer, value range: 1~2. the default value is 1. Note: for BTS1.X, LEVELNUM=1. 9) L1RACK (L1 Rack No.): rack number for the level 1 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 1~4. 10) L1SHELF (L1 Shelf No.): shelf number for the level 1 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 1~4. 11) L1PANEL (L1 Panel No.): panel number for the level 1 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 1~16. 12) L2RACK (L2 Rack No .): rack number for the level 2 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 0~4, the default value is 0. 13) L2SHELF (L2 Shelf No.): shelf number for the level 2 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 0~4, the default value is 0. 14) L2PANEL (L2 Panel No.): panel number for the level 2 HYCOM/MUL corresponding to the TRU. Signless integer, value range: 0~16, the default value is 0.
Page 440 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.176 ETXD 1. Command function To delete a connecting relation between TRU panel and HYCOM/MUL panel: TRUMulHyc MO. 2. Syntax structure ETXD: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO, PORTTYPE; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) PANELNO ( Panel No.): panel number of the TRU. Signless integer, value range: 1~16. 7) PORTTYPE (Port Type): type of the port for connecting the transceiver module and AEM (TX, RX, RXD), i.e., connecting mode. Enumerated type, value range: 1, 2, 4. Among them, 1: TX (HYCOM) ; 2: RX (MUL) ; 4: RXD. 1.5.3.177 ETXQ 1. Command function
Page 441 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To view the attribute of the connecting relation between TRU panel and HYCOM/MUL panel: TRUMulHyc MO. 2. Syntax structure ETXQ: EBSSID {, ESITEID, ESITENM}, RACKNO, SHELFNO, PANELNO, PORTTYPE: PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) SHELFNO (Shelf No.): Shelf number. Signless integer, value range: 1~5. 6) PANELNO ( Panel No.): panel number of the TRU. Signless integer, value range: 1~16. 7) PORTTYPE (Port Type): type of the port for connecting the transceiver module and AEM (TX, RX, RXD), i.e., connecting mode. Enumerated type, value range: 1, 2, 4. Among them, 1: TX (HYCOM) ; 2: RX (MUL) ; 4: RXD. 8) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL. 1.5.3.178 EUCC 1. Command function

Page 442 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To create a BieCom. 2. Syntax structure EUCC: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS: BIESUBTS: KIND: DSTSITE, DSTRACK, DSTSHELF, DSTPANEL, CHANNEL; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 6) BIETS (BIE Time Slot): BIE time slot number. Signless integer, value range: 0~31. 7) BIESUBTS (BIE Sub Time Slot): BIE sub-time slot number. Enumerated type, value range: 0, 1. 2, 3, 251, 252, 253, 254, 255. 8) KIND (Kind): type. Enumerated type, value range: 1~4. Among them, 1: ABIS_TSTYPE_IN; 2: ABIS_TSTYPE_OMU_LAPD; 3: ABIS_TSTYPE_TRX_LAPD; 4: ABIS_TSTYPE_EAM. 9) DSTSITE (DST Site No.): adjacent site number. Signless integer, value range: 1~1024.

Page 443 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

10) DSTRACK (DST Rack No.): adjacent BTS rack number. Signless integer, value range: 0~4. 11) DSTSHELF (DST Shelf No.): adjacent BTS shelf number. Signless integer, value range: 0~4. 12) DSTPANEL (DST Panel No.): adjacent BTS panel number. Signless integer, value range: 0~16. 13) CHANNEL (Channel No.): channel No. Signless integer, value range: when KIND = 1, i.e., ABIS_TSTYPE_IN, value range is 0~7; for other kinds, the value range is 1~255. 1.5.3.179 EUCD 1. Command function To delete a BieCom. 2. Syntax structure EUCD: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS, BIESUBTS; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4.

Page 444 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) BIEPCM (BIE Pcm): PCM No. of the BS E1 interface. Signless integer, value range: 1~6. 6) BIETS (BIE Time Slot): BIE time slot number. Signless integer, value range: 0~31. 7) BIESUBTS (BIE Sub Time Slot): BIE sub-time slot number. Enumerated type, value range: 0, 1. 2, 3, 251, 252, 253, 254, 255. 1.5.3.180 EUCQ 1. Command function To view the related attribute of a BieComs adjacent site. 2. Syntax structure EUCQ: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM, BIETS, BIESUBTS: PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 6) BIETS (BIE Time Slot): BIE time slot number. Signless integer, value range: 0~31.
Page 445 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) BIESUBTS (BIE Sub Time Slot): BIE sub-time slot number. Enumerated type, value range: 0, 1. 2, 3, 251, 252, 253, 254, 255. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, value range: ALL. 1.5.3.181 EUPC 1. Command function To create an BS E1 interface PCM (BiePcm). 2. Syntax structure EUPC: EBSSID {, ESITEID, ESITENM}, RACKNO (Rack No): BIEPCM; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 1.5.3.182 EUPD 1. Command function To delete an BS E1 interface PCM (BiePcm).

Page 446 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure EUPD: EBSSID {, ESITEID, ESITENM}, RACKNO (Rack No): BIEPCM; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024. 3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 1.5.3.183 EUPQ 1. Command function To view the attribute of an BS E1 interface PCM (BiePcm). 2. Syntax structure EUPQ: EBSSID {, ESITEID, ESITENM}, RACKNO, BIEPCM: PARAGRP; 3. Parameter description 1) EBSSID: BSS Identification. Signless integer, value range: 1~255. 2) ESITEID: Site Equipment Identification. Signless integer, value range: 1~1024.

Page 447 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) ESITENM: Site Equipment Name. Character string type, the maximum length of the character string is 40. 4) RACKNO (Rack No.): rack No. of the shelf. Signless integer, value range: 1~4. 5) BIEPCM (BIE Pcm): PCM No . of the BS E1 interface. Signless integer, value range: 1~6. 6) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL. 1.5.3.184 CMCC 1. Command function To create a MSC. 2. Syntax structure CMCC: {MSCID, MSCNAME}: ALIAS: [L, B]: DPC [, SPTYPE ]; 3. Parameter description 1) MSCID: MSC identification. Signless integer, value range: 1~255. 2) MSCNAME: MSC name. Character string type, the maximum length of the character string is 40. 3) L (Longitude): longitude coordinate of MSC location. Floating-point type, value range: -180~180, to the accuracy of 2 digits after the decimal point, the default value is 0. 4) B (Latitude): latitude coordinate of MSC location. Floating-point type, value range: -90~90, to the accuracy of 2 digits after the decimal point, the default value is 0.

Page 448 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) DPC (Destination Point Code): MSC signaling point code. Signless integer, value range: 0~16383. 6) SPTYPE ( Signaling Point Type): MSC signaling point type. Signless integer, value range: 1~3, the default value is 3. Among them, 1: SPT_SEP signaling end point (SEP); 2: SPT_STP signaling transfer point (STP); 3: SPT_STEP signaling transfer/end point STEP. 1.5.3.185 CMCD 1. Command function To delete a MSC. 2. Syntax structure CMCD: {MSCID, MSCNAME}; 3. Parameter description 1) MSCID: MSC identification. Signless integer, value range: 1~255. 2) MSCNAME: MSC name. Character string type, Character string ? the maximum length is 40. 1.5.3.186 CMCM 1. Command function To modify the attribute of a MSC. 2. Syntax structure CMCM: {MSCID, MSCNAME}: [ALIAS] [, L] [, B] [, DPC, SPTYPE]; 3. Parameter description 1) MSCID: MSC identification. Signless integer, value range: 1~255.
Page 449 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) MSCNAME: MSC name. Character string type, the maximum length of the character string is 40. 3) L (Longitude): Longitude coordinate of MSC location. Floating-point type, value range: -180~180, to the accuracy of 2 digits after the decimal point, the default value is 0. 4) B (Latitude): latitude coordinate of MSC location. Floating-point type, value range: -90~90, to the accuracy of 2 digits after the decimal point, the default value is 0. 5) DPC (Destination Point Code): MSC signaling point code. Signless integer, value range: 0~16383. 6) SPTYPE ( Signaling Point Type): MSC signaling point type. Signless integer, value range: 1~3, the default value is 3. Among them, 1: SPT_SEP signaling end point (SEP); 2: SPT_STP signaling transfer point (STP); 3: SPT_STEP signaling transfer/end point STEP. 1.5.3.187 CMCQ 1. Command function To query the attribute of a MSC. 2. Syntax structure CMCQ: {MSCID, MSCNAME}: PARAGRP; 3. Parameter description 1) MSCID: MSC identification. Signless integer, value range: 1~255. 2) MSCNAME: MSC name. Character string type, Character string ? the maximum length is 40. 3) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL.
Page 450 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.188 NLKC 1. Command function To create a SS7 link. 2. Syntax structure NLKC: { EBSCID, EBSCNAME}: LINKID: SLC: CSLOTNO, BCH, LINKSET: TMODULE, tMUNIT, tUNIT, tPCM, tINDEX; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) LINKID (Link Identification): SS7 link identification. Signless integer, value range: 1~16. 4) SLC (Signaling Link Code): SS7 link number. Signless integer, value range: 0~15. 5) CSLOTNO (Comm Slot No.): slot number of the MTP board. Signless integer, value range: 0~27. 6) BCH (Base Channel): sequence number of the SS7 link on the MTP board slot. Signless integer, value range: 0~7. 7) LINKSET (Link Set): signaling link set number of the signaling link. Signless integer, with a value of 1. The default value is 1. 8) TMODULE (Trunk Module): module number of the signaling link trunk. Signless integer, value range: 1~64.

Page 451 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

9) TMUNIT (Trunk Multiple Unit): multi-unit name of the signaling link trunk. Signless integer, value range: 2 to 127. 10) TUNIT (Trunk Unit): unit name of the signaling link trunk. Signless integer, value range: 0~16. 11) TPCM (Trunk PCM): sub-unit name of the signaling link trunk (PCM line number). Signless integer, value range: 1~4. 12) TINDEX (Trunk Index): sequence number of the time slot in the sub-unit of the signaling link trunk. Signless integer, value range: 0~31. 1.5.3.189 NLKD 1. Command function To delete a SS7 link. 2. Syntax structure NLKD: {EBSCID, EBSCNAME}, LINKID; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) LINKID (Link Identification): SS7 link identification. Signless integer, value range: 1~16. 1.5.3.190 NLKM 1. Command function To modify a SS7 link parameter: signaling link code (SLC).
Page 452 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure NLKM: {EBSCID, EBSCNAME}, LINKID: SLC; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) LINKID (Link Identification): SS7 link identification. Signless integer, value range: 1~16. 4) SLC (Signaling Link Code): SS7 link number. Signless integer, value range: 0~15. 1.5.3.191 NLKQ 1. Command function To view the attribute of a SS7 link: static attribute or dynamic attribute ( SpyStatus, Ad). 2. Syntax structure NLKQ: {EBSCID, EBSCNAME}, LINKID: PARAGRP; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40.

Page 453 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) LINKID (Link Identification): SS7 link identification. Signless integer, value range: 1~16. 4) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL, STATES. Among them, ALL: viewing static attribute; STATES: viewing dynamic attribute. 1.5.3.192 NPMC 1. Command function To create a N7PCM (A interface PCM code). 2. Syntax structure NPMC: { EBSCID, EBSCNAME }: N7PCM: MODULENO, MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) N7PCM (N7 PCM): signaling No.7 PCM code. Signless integer, value range: 0~127. 4) MODULENO (Module No.): module number of the A interface PCM. Signless integer, value range: 1, the default value is 1. 5) MUNIT (Multiple Unit): multi-unit name of the A interface PCM. Signless integer, value range: 2 to 127. 6) UNIT (Unit): unit name of the A interface PCM. Signless integer, value range: 0~16.

Page 454 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

7) PCMNO (PCM No.): PCM line number of the A interface PCM. Signless integer, value range: 1~4. 1.5.3.193 NPMD 1. Command function To delete a N7PCM. 2. Syntax structure NPMD: { EBSCID, EBSCNAME }, N7PCM; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) N7PCM (N7 PCM): signaling No.7 PCM code. Signless integer, value range: 0~127. 1.5.3.194 NPMM 1. Command function To modify the attribute of a N7PCM. 2. Syntax structure NPMM: { EBSCID, EBSCNAME }, N7PCM: MUNIT, UNIT, PCMNO; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255.
Page 455 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) N7PCM (N7 PCM): signaling No.7 PCM code. Signless integer, value range: 0~127. 4) MUNIT (Multiple Unit): multi-unit name of the A interface PCM. Signless integer, value range: 2 to 127. 5) UNIT (Unit): unit name of the A interface PCM. Signless integer, value range: 0~16. 6) PCMNO (PCM No.): PCM line number of the A interface PCM. Signless integer, value range: 1~4. 1.5.3.195 NPMQ 1. Command function To view the attribute of a N7PCM. 2. Syntax structure NPMQ: { EBSCID, EBSCNAME }, N7PCM: PARAGRP; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) N7PCM (N7 PCM): signaling No.7 PCM code. Signless integer, value range: 0~127. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, value range: ALL, the default value is ALL.
Page 456 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.196 NRTC 1. Command function To create a No.7 route (N7Route). 2. Syntax structure NRTC: {EBSCID, EBSCNAME}: ROUTEID : LINKSET1, LINKSET2, LPM; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the signaling No.7 route. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) ROUTEID (Route Identification): signaling No .7 route number. Signless integer, with a value of 1, the default value is 1. 4) LINKSET1 (Link Set 1): signaling link set number 1. Signless integer, with a value of 1, the default value is 1. 5) LINKSET2 (Link Set 2): signaling link set number 2. Signless integer, with a value of 0, the default value is 0. 6) LPM (Link Permutation Method): signaling link permutation mode. Signless integer, value range: 0~4, the default value is 4. Among them, 0: random permutation; 1: select link set by SLS_bit0, and linkset_1/linkset_2 is selected when SLS_bit0=0/1; 2: select link set by SLS_bit1, and linkset_1/linkset_2 is selected when SLS_bit1=0/1; 3: select link set by SLS_bit2, and linkset_1/linkset_2 is selected when SLS_bit2=0/1; 4: select link set by SLS_bit3, and linkset_1/linkset_2 is selected when SLS_bit3=0/1.

Page 457 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

1.5.3.197 NRTD 1. Command function To delete a No.7 route (N7Route ). 2. Syntax structure NRTD: {EBSCID, EBSCNAME}, ROUTEID; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the signaling No.7 route. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) ROUTEID (Route Identification): signaling No .7 route number. Signless integer, with a value of 1, the default value is 1. 1.5.3.198 NRTM 1. Command function To modify the LPM attribute of a No.7 route (N7Route). 2. Syntax structure NRTM: {EBSCID, EBSCNAME}, ROUTEID: LPM; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the signaling No.7 route. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40.
Page 458 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) ROUTEID (Route Identification): signaling No .7 route number. Signless integer, with a value of 1, the default value is 1. 4) LPM (Link Permutation Method): signaling link permutation mode. Signless integer, value range: 0~4. Among them, 0: random permutation; 1: select link set by SLS_bit0, and linkset_1/linkset_2 is selected when SLS_bit0=0/1; 2: select link set by SLS_bit1, and linkset_1/linkset_2 is selected when SLS_bit1=0/1; 3: select link set by SLS_bit2, and linkset_1/linkset_2 is selected when SLS_bit2=0/1; 4: select link set by SLS_bit3, and linkset_1/linkset_2 is selected when SLS_bit3=0/1. 1.5.3.199 NRTQ 1. Command function To view the attribute of a No.7 route (N7Route). 2. Syntax structure NRTQ: {EBSCID, EBSCNAME}, ROUTEID: PARAGRP; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the signaling No.7 route. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) ROUTEID (Route Identification): signaling No .7 route number. Signless integer, with a value of 1, the default value is 1. 4) PARAGRP (Parameter Group): attribute package type. Enumerated type, value range: ALL. 1.5.3.200 NSNC 1. Command function
Page 459 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

To create CSS7 subsystem. 2. Syntax structure NSNC: {EBSCID, EBSCNAME}, OFFICEID : SSN, OFFFICE1, SSN1; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) OFFICEID (Office Identification): office identification corresponding to the signaling point. Signless integer, with a value of 0~1. Among them, 0: BSC_OFFICE refers to BSC signaling point; 1: MSC_OFFICE refers to MSC signaling point 4) SSN (Sub System No.): sub-system number. Enumerated type, with a value of 1, 252, 253, 254. Among them, 1: SCCP management (SCMG); 0xFC (252): MSC simulation (self-defined subsystem); 0xFD (253): BSSOMAP; 0xFE (254): BSSAP 5) OFFFICE1 (Office 1): the office identification of the standby subsystem (OFFFICE1, SSN1) corresponding to the subsystem (OFFICEID, SSN). Signless integer, with a value of 0, the default value is 0. 6) SSN1 (Sub System No.1): the subsystem number of the standby subsystem (OFFFICE1, SSN1) corresponding to the subsystem (OFFICEID, SSN).. Signless integer, with a value of 0, the default value is 0. 1.5.3.201 NSND 1. Command function To delete a CSS7 subsystem.
Page 460 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure NSND: {EBSCID, EBSCNAME}, OFFICEID, SSN; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) OFFICEID (Office Identification): office identification corresponding to the signaling point. Signless integer, with a value of 0~1. Among them, 0: BSC_OFFICE refers to BSC signaling point; 1: MSC_OFFICE refers to MSC signaling point. 4) SSN (Sub System No.): sub-system number. Enumerated type, with a value of 1, 252, 253, 254. Among them, 1: SCCP management (SCMG) ; 0xFC (252): MSC simulation (self-defined subsystem); 0xFD (253): BSSOMAP; 0xFE (254): BSSAP. 1.5.3.202 NSNQ 1. Command function To query the attribute of a CSS7 subsystem: static attribute or dynamic attribute ( SpyStatus, Op, Av). 2. Syntax structure NSNQ: {EBSCID, EBSCNAME}, OFFICEID, SSN: PARAGRP; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255.

Page 461 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) OFFICEID (Office Identification): office identification corresponding to the signaling point. Signless integer, with a value of 0~1. Among them, 0: BSC_OFFICE refers to BSC signaling point; 1: MSC_OFFICE refers to MSC signaling point. 4) SSN (Sub System No.): sub-system number. Enumerated type, with a value of 1, 252, 253, 254. Among them, 1: SCCP management (SCMG) ; 0xFC (252): MSC simulation (self-defined subsystem); 0xFD (253): BSSOMAP; 0xFE (254): BSSAP. 5) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL, STATES. Among them, ALL: viewing static attribute; STATES: viewing dynamic attribute. 1.5.3.203 NSTC 1. Command function To create a SCCP timer. 2. Syntax structure NSTC: { EBSCID, EBSCNAME }: TMCONN, tMIAS, tMIAR, tMRELAY, tMGUARD, tMIGNORE, tMINTERV, tMFREEZE: LENT3, LENT4: L3TIMER1, L3TIMER2, L3TIMER3, L3TIMER4, L3TIMER5: TFPT, SRST: OWST18, OWST19, OWST20, ADRSTT21; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40.

Page 462 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3) TMCONN: the maximum time delay from sending CR to receiving CC (100ms). Signless integer, value range: 0~4294967295, the default value is 600. 4) TMIAS: timer for inactive sending (100ms). Signless integer, value range: 0~4294967295, the default value is 900. 5) TMIAR: timer for inactive receiving. Signless integer, value range: 0~4294967295, the default value is 2400. 6) TMRELAY: from sending RLSD to receiving RLC. Signless integer, value range: 0~4294967295, the default value is 150. 7) TMGUARD: time taken from restarting to sending the first connectionoriented message. Signless integer, value range: 0~4294967295, the default value is 4800. 8) TMIGNORE (Ignore Time): time for ignoring SST. Signless integer, value range: 0~4294967295, the default value is 1200. 9) TMINTERV (Interval Time): release protection time. Signless integer, value range: 0~4294967295, the default value is 600. 10) TMFREEZE (Freeze Time): section freezing time. Signless integer, value range: 0~4294967295, the default value is 300. 11) LENT3: time for waiting for SLTA after sending SLTM. Signless integer, value range: 0~4294967295, the default value is 80. 12) LENT4: period for sending SLTM. Signless integer, value range: 0~4294967295, the default value is 600. 13) L3TIMER1: time delay for avoiding wrong message sequence during changeover. Signless integer, value range: 0~4294967295, the default value is 8. 14) L3TIMER2: waiting for changeover acknowledgement. Signless integer, value range: 0~4294967295, the default value is 10.
Page 463 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

15) L3TIMER3: time delay for avoiding wrong message sequence during changeback. Signless integer, value range: 0~4294967295, the default value is 8. 16) L3TIMER4: waiting for changeback acknowledgement (the first attempt). Signless integer, value range: 0~4294967295, the default value is 10. 17) L3TIMER5: waiting for changeback acknowledgement (the second attempt). Signless integer, value range: 0~4294967295, the default value is 10. 18) TFPT: timer for forbidding transfer inhibition. Signless integer, value range: 0~4294967295, the default value is 10. 19) SRST: waiting for repeating signaling route set test messages. Signless integer, value range: 0~4294967295, the default value is 450. 20) OWST18: timer for restarting STP and waiting for the signaling link to be available. Signless integer, value range: 0~4294967295, the default value is 100. 21) OWST19: starting after T 18, and waiting for receiving all TRA messages. Signless integer, value range: 0~4294967295, the default value is 680. 22) OWST20: starting after T19, and waiting for broadcasting TRA and restarting other services. Signless integer, value range: 0~4294967295, the default value is 600. 23) ADRSTT21: waiting for the restarting services of adjacent signaling point routes. Signless integer, value range: 0~4294967295, the default value is 640. 1.5.3.204 NSTD 1. Command function To delete a SCCP timer.
Page 464 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2. Syntax structure NSTD: {EBSCID, EBSCNAME}; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 1.5.3.205 NSTM 1. Command function To modify the parameter value of each timer among SCCP timers. 2. Syntax structure NSTM: { EBSCID, EBSCNAME}: TMCONN, tMIAS, tMIAR, tMRELAY, tMGUARD, tMIGNORE, tMINTERV, tMFREEZE: LENT3, LENT4: L3TIMER1, L3TIMER2, L3TIMER3, L3TIMER4, L3TIMER5: TFPT, SRST: OWST18, OWST19, OWST20, ADRSTT21; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) TMCONN: the maximum time delay from sending CR to receiving CC (100ms). Signless integer, value range: 0~4294967295, the default value is 600.

Page 465 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) TMIAS: timer for inactive sending (100ms). Signless integer, value range: 0~4294967295, the default value is 900. 5) TMIAR: timer for inacti ve receiving. Signless integer, value range: 0~4294967295, the default value is 2400. 6) TMRELAY: from sending RLSD to receiving RLC. Signless integer, value range: 0~4294967295, the default value is 150. 7) TMGUARD: time taken from restarting to sending the first connectionoriented message. Signless integer, value range: 0~4294967295, the default value is 4800. 8) TMIGNORE (Ignore Time): time for ignoring SST. Signless integer, value range: 0~4294967295, the default value is 1200. 9) TMINTERV (Interval Time): release protection time. Signless integer, value range: 0~4294967295, the default value is 600. 10) TMFREEZE (Freeze Time): section freezing time. Signless integer, value range: 0~4294967295, the default value is 300. 11) LENT3: time for waiting for SLTA after sending SLTM. Signless integer, value range: 0~4294967295, the default value is 80. 12) LENT4: period for sending SLTM. Signless integer, value range: 0~4294967295, the default value is 600. 13) L3TIMER1: time delay for avoiding wrong message sequence during changeover. Signless integer, value range: 0~4294967295, the default value is 8. 14) L3TIMER2: waiting for changeover acknowledgement. Signless integer, value range: 0~4294967295, the default value is 10. 15) L3TIMER3: time delay for avoiding wrong message sequence during changeback. Signless integer, value range: 0~4294967295, the default value is 8.
Page 466 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

16) L3TIMER4: waiting for changeback acknowledgement (the first attempt). Signless integer, value range: 0~4294967295, the default value is 10. 17) L3TIMER5: waiting for changeback acknowledgement (the second attempt). Signless integer, value range: 0~4294967295, the default value is 10. 18) TFPT: timer for forbidding transfer inhibition. Signless integer, value range: 0~4294967295, the default value is 10. 19) SRST: waiting for repeating signaling route set test messages. Signless integer, value range: 0~4294967295, the default value is 450. 20) OWST18: timer for restarting STP and waiting for the signaling link to be available. Signless integer, value range: 0~4294967295, the default value is 100. 21) OWST19: starting after T 18, and waiting for receiving all TRA messages. Signless integer, value range: 0~4294967295, the default value is 680. 22) OWST20: starting after T19, and waiting for broadcasting TRA and restarting other services. Signless integer, value range: 0~4294967295, the default value is 600. 23) ADRSTT21: waiting for the restarting services of adjacent signaling point routes. Signless integer, value range: 0~4294967295, the default value is 640. 1.5.3.206 NSTQ 1. Command function To view the parameter value of each timer among SCCP timers. 2. Syntax structure NSTQ: { EBSCID, EBSCNAME }: PARAGRP;
Page 467 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

3. Parameter description 1) EBSCID (BSC Identification): BSC identification of the SS7 link. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) PARAGRP (Parameter Group): parameter attribute package type. Enumerated type, value range: ALL. 1.5.3.207 NTSM 1. Command function To modify the circuit code of a SS7 time slot (an ATRUNK object is created automatically when ATIC is created in the physical configuration, and the default initial value of parameter CicNo in ATRUNK is set to the same value as the TS: 0~31). 2. Syntax structure NTSM: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCM, tSID: CICNO; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): module number of the ATRUNK. Signless integer, value range: 1~64. 4) MUNIT (Multiple Unit): multi-unit name of the ATRUNK. Signless integer, value range: 2 to 127.
Page 468 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): unit name of the ATRUNK. Signless integer, value range: 0~16. 6) PCM (PCM No.): PCM line number of the ATRUNK. Signless integer, value range: 1~4. 7) TSID (Time Slot Identification): time slot number of the ATRUNK. Signless integer, value range: 0~31. 8) CICNO (Circuit No.): TS circuit number. Signless integer, value range: 0~31. 1.5.3.208 NTSQ 1. Command function To view an SS7 TS circuit number. 2. Syntax structure NTSQ: {EBSCID, EBSCNAME}, MODULENO, MUNIT, UNIT, PCM, tSID: PARAGRP; 3. Parameter description 1) EBSCID (BSC Identification): BSC identification. Signless integer, value range: 1~255. 2) EBSCNAME ( BSC Name): BSC alias. Character string type, the maximum length of the character string is 40. 3) MODULENO (Module No.): module number of the ATRUNK. Signless integer, value range: 1~64. 4) MUNIT (Multiple Unit): multi-unit name of the ATRUNK. Signless integer, value range: 2 to 127.

Page 469 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

5) UNIT (Unit): unit name of the ATRUNK. Signless integer, value range: 0~16. 6) PCM (PCM No.): PCM line number of the ATRUNK. Signless integer, value range: 1~4. 7) TSID (Time Slot Identification): time slot number of the ATRUNK. Signless integer, value range: 0~31. 8) PARAGRP (Parameter Group): attribute package type. Enumerated type, value range: ALL.

Page 470 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2
2.1

Operation
Overview
In volume one, we have described in detail the operation of each module and menu in the OMCR (V2) system. On this basis, this chapter will describe the commonly used operation for each module, including the following contents: 1. Security management 1) User management 2) Operation log 2. Configuration management 1) Radio resources management 2) Software loading 3) Dynamic data management 4) Integrated configuration management 3. Fault management 1) Alarm management 2) Test management 4. Performance management 1) Performance management 2) Performance analyzer 3) Invoke tracing
Page 471 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

4) Signaling tracing

2.2
2.2.1

Security management
User management In the main interface of OMCR (V2) (please refer to Fig.2-10 in volume 1), select security management ? user management to enter the user management interface, as shown in Fig. 2-1.

Fig. 2-1 User management 2.2.1.1 Role setting Click the Role tool button in the left tree to enter the role management interface, as shown in Fig. 2-2.

Page 472 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-2 Role management Select Operation? Create role. The dialog box for creating a role will pop up, as shown in Fig. 2-3.

Fig. 2-3 Create a role 2.2.1.2 User group setting Click the Group tool button in the left tree to enter the user group management interface, as shown in Fig. 2-4.

Page 473 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-4 User group management Select Operation ? Create group. The dialog box for creating a user group will pop up, as shown in Fig. 2-5.

Fig. 2-5 Create a new user group 2.2.1.3 User setting By clicking User in the left tree, you can view a list of users, as shown in Fig. 2-6.

Page 474 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-6 User management Select Operation? Create user, as shown in Fig. 2-7.

Fig. 2-7 Create a new user 2.2.2 Operation log In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Security management? Operation log to enter the operation log interface. During starting up, the user is allowed to make preliminary filtering, so as to locate to the desired logs. You can directly click the OK button to view the latest 1000 logs in the last week, as shown in Fig. 2-8.

Page 475 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-8 Main interface of operation log--preliminary filtering After licking OK, the main interface of operation log appears, as shown in Fig. 2-9.

Fig. 2-9 Main interface of operation log

Page 476 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Select a log item for viewing detailed information from the operation log interface shown in Fig. 2-9, and double -click it or select the View? Detail Information menu, the Detail Information dialog box will pop up, as shown in Fig. 2-10.

Fig. 2-10 Detailed information Select the Log? Save as menu. The Save As dialog box will pop up, as shown in Fig. 2-11.

Fig. 2-11 Saving log

Page 477 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2.3
2.3.1

Configuration management
Radio resource management In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Configuration Management? Radio Resource Management to enter the ZXG10 Radio Resource Management interface, as shown in Fig. 2-12.

Fig. 2-12 Main interface 2.3.1.1 Configuring sites In Fig. 2-12, right-click a BSS, and in the pop-up menu, select Create a logic site. Then a dialog box as shown in Fig. 2-13 will pop up.

Page 478 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-13 Configuring a site 2.3.1.2 Configuring BSC In Fig. 2-12, right-click a BSS, and in the pop-up menu, select Create a BSC. Then an interface for configuring BSC will pop up, and you can respectively configure the basic property and timer of the BSC in the interface. The basic property setting of the BSC in a GSM environment is as shown in Fig. 2-14, and that in a GPRS environment is as shown in Fig. 2-15.

Page 479 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-14 Configuring BSC 1)GSM

Fig. 2-15 Configuring BSC 1)GPRS The timer setting of the BSC in a GSM environment is as shown in Fig. 216, and that in a GPRS environment is as shown in Fig. 2-17.

Page 480 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-16 Configuring BSC 2)GSM

Fig. 2-17 Configuring BSC 2)GPRS The maximum number of GPRS retry times for the BSC is shown in Fig. 218.

Page 481 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-18 Configuring BSC 3) The GPRS timer setting of the BSC is shown in Fig. 2-19.

Fig. 2-19 Configuring BSC 4) The other GPRS property setting of the BSC is shown in Fig. 2-20.

Page 482 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-20 Configuring BSC 5) 2.3.2 Software loading In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Configuration management ? Software loading to enter the main interface of software loading (as shown in Fig. 2-21).

Page 483 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-21 Main interface of software loading 2.3.2.1 Logic view Select menu View? Logic view to enter the logic view interface of software loading, as shown in Fig. 2-22.

Fig. 2-22 Logic view In Fig. 2-22, right-click Stored software, and select Store Software from the pop-up menu. Then the Store Software interface will pop up, which is as shown in Fig. 2-23 for the GSM environment, and as shown in Fig. 2-24 for the GPRS environment.

Page 484 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-23 Store software GSM

Fig. 2-24 Store software GPRS

Page 485 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2.3.2.2

Physical view Select menu View? physical view to enter the physical view interface of software loading, as shown in Fig. 2-25.

Fig. 2-25 BSC loading rack diagram display In Fig. 2-25, right-click a board on the rack diagram, and select Create version from the pop-up menu to create board software, as shown in Fig. 2-26.

Page 486 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-26 Create BOSN board software The software loading for sites (including micro-cell sites) is different from that of BSC. From the browse tree in the physical view interface of software loading, select the site under the BSC for software loading. The interface is as shown in Fig. 2-27.

Page 487 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-27 Software loading for a site 2.3.3 Dynamic data management In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Configuration management ? Dynamic data management to enter the Dynamic data management main interface, as shown in Fig.2-28.

Page 488 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-28 Main interface of d ynamic data management 2.3.3.1 Query/refresh You can view the status of land resources with dynamic property, as shown in Fig.2-29. From the list on the right, select the channel to be queried and right-click it. Then select Watch from the pop-up menu to get the queried result of the channel status.

Page 489 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-29 Status query Refreshing is used to query the statuses of all channels or time slots. As shown in Fig.2-30, right-click the lower-right list in the main interface, and select Refresh from the pop-up menu to get the statuses of all channels

Page 490 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-30 Status refreshing 2.3.3.2 Blocking/unblocking Blocking/unblocking is used to modify the status bit of such land resources as BSC, BTS and TRX with dynamic property. To illustrate with the channel, select channel 2 to be queried from the list on the right, and rightclick it. Then select Block or Unblock from the pop-up menu to initiate the operation for modifying the management status of channel 2, as shown in Fig.2-31.

Fig. 2-31 Blocking/unblocking 2.3.3.3 Activation/deactivation Activation/deactivation refers to activating/deactivating N7LINK. From the list on the right, select the N7LINK1 to be activated/deactivated, and rightclick it. Then select Activate or Unactivate from the pop-up menu to initiate the operation for activating/deactivating N7LINK1, as shown in Fig.2-32.

Page 491 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-32 Activating/deactivating 2.3.3.4 Setting/unsetting PCM circuits Setting/unsetting refers to setting/unsetting PCM circuits. From the list on the right, select the PCM circuit to be set/unset, and right-click it. Then select Set or Unset from the pop-up menu to initiate the operation for setting/unsetting the PCM circuit, as shown in Fig.2-33.

Page 492 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-33 setting/unsetting a PCM circuit 2.3.3.5 Global reset From the tree list on the left of the main interface, right-click GSM equipment or BSC equipment, and select Global reset from the pop-up menu to initiate the operation for global reset, as shown in Fig.2-34.

Page 493 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-34 Global reset 2.3.4 Integrated configuration management In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select the Configuration management? Integrated configuration management menu item. First, you need to select the configuration mode, as shown in Fig.2-35. You can select Initial Configuration (Create a BSC) and click OK to enter the initial configuration wizard; or select Modify Configuration (Edit Data) and click OK to enter the wizard for modifying configuration. If you click Cancel, you can enter the status only for editing script. After the settings in the wizard are completed, the main interface of integrated configuration management appears, as shown in Fig.2-36.

Page 494 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-35 Selecting configuration mode

Fig. 2-36 Main interface of integrated configuration management 2.3.4.1 Initial configuration In Fig. 2-35, select Initial Configuration (Create a BSC) and click OK to enter the interface as shown in Fig.2-37.

Page 495 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-37 The second step of the wizard Click Next to enter the wizard for creating MSC, as shown in Fig.2-38.

Fig. 2-38 Editing MSC Click Next to enter the wizard for editing BSC, as shown in Fig.2-39.
Page 496 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-39 Configuring BSC 2.3.4.2 Modifying configuration In Fig. 2-35, select Modify Configuration (Edit Data), and the system will get data script from the database first, as shown in Fig.2-40.

Page 497 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-40 Increment configuration 1) Enter the BSCID for modifyi ng configuration. Note that this BSCID must exist in the system. Then the system begins to get data, as shown in Fig.2-41.

Fig. 2-41 Increment configuration 2) After the data are acquired successfully from the database, the step 2 dialog box of the wi zard pops up automatically, as shown in Fig.2-42.

Fig. 2-42 Increment configuration 3) Click Next to enter the step for editing script. The following operations are the same as those of the initial configuration.

Page 498 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2.4
2.4.1 2.4.1.1

Fault management
Alarm management Viewing alarms After the user logs in successfully, in the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Fault management ? Alarm management to enter the main interface of alarm management (as shown in Fig.2-43).

Fig. 2-43 Main interface of alarm management Select an alarm item or notification item from the alarm list or notification list, then click the Detailed information tool button on the toolbar or double-click the selected alarm item or notification item. A dialog box will pop up (as shown in Fig.2-44), which displays the detailed information of the selected alarm item or notification item.

Page 499 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-44 Detailed information Select a rack to be viewed from the browse tree, or click the Physical view tool button on the toolbar provided that a BSC or BTS has been selected in the browse tree to enter the interface for displaying alarm management rack diagram (as shown in Fig.2-45).

Fig. 2-45 BSC alarm management rack diagram Right-click a board on the BSC rack diagram, and select Query board status from the shortcut menu. Then a dialog box for displaying the board status will pop up, as shown in Fig.2-46.

Page 500 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-46 Displaying board status 2.4.1.2 Alarm rule setting In Fig. 2-43, select Setting ? Alarm rule ? Alarm filter rule to enter the dialog box of alarm filter rule editor (as shown in Fig.2-47).

Fig. 2-47 Alarm filter rule editor In Fig. 2-43, select Setting ? Alarm rule ? Alarm reclassification rule to enter the dialog box of alarm reclassification rule editor (as shown in Fig.248).

Page 501 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-48 Alarm reclassification rule editor In Fig. 2-43, select Setting ? Alarm rule ? Alarm correlation rule to enter the dialog box of alarm correlation rule editor (as shown in Fig.2-49).

Fig. 2-49 Alarm correlation rule editor 2.4.1.3 Trunk node alarm In Fig. 2-43, select Setting ? Trunk node alarm? Set trunk node alarm to enter the dialog box for setting trunk node alarm, as shown in Fig.2-50.

Page 502 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-50 Setting trunk node alarm 1) First, select the BSS, site and rack for setting trunk node alarm, then select the template to be set from the pull-down list of template numbers. Then the dialog box will list the alarm class and content for each node under the template, as shown in Fig.2-51.

Fig. 2-51 Setting trunk node alarm 2) In the dialog box for setting trunk node alarm, click the New Template button to enter the dialog box for creating a new trunk node alarm template, as shown in Fig.2-52.

Page 503 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-52 Creating a new trunk node alarm template 2.4.2 Test management After logging in successfully, in the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Fault management? Test management to enter the main interface of test management (as shown in Fig.2-53).

Fig. 2-53 Test management main interface 2.4.2.1 Instant test Expand the browse tree, and select the BSC to be tested. Then select Test mode? Instant test to enter the instant test interface, as shown in Fig.2-54.
Page 504 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-54 Instant test Select Instant test? Create test items. The dialog box for creating instant test items will pop up, as shown in Fig.2-55.

Fig. 2-55 Creating instant test items 2.4.2.2 Scheduled test Select the BSC to be tested, and then select Test mode? Scheduled test to enter the scheduled test interface, as shown in Fig.2-56.

Page 505 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-56 Scheduled test After new scheduled test items are created, the original scheduled test items will be automatically deleted. The test results generated in executing new scheduled test items will be saved in the test database together with the original test results. Select Scheduled test ? Set scheduled test to enter the dialog box for setting scheduled test, which is as shown in Fig.257 in the GSM environment, and is as shown in Fig.2-58 in the GPRS environment.

Fig. 2-57 Setting scheduled testGSM

Page 506 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-58 Setting scheduled testGPRS

2.5
2.5.1

Performance management
Performance management After logging in successfully, in the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Performance management? Performance management to enter the main interface of performance management (as shown in Fig.2-59).

Fig. 2-59 Main interface of performance management

Page 507 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2.5.1.1

Measurement job Select a specific measurement job from the browse tree. Then the right part of the interface will be divided into three blocks, which respectively display the list, schedule and measurement object of the job, as shown in Fig.2-60.

Fig. 2-60 Display of a single measurement job In Fig. 2-59, select Measurement jobs from the left browse tree, and then click menu Performance management ? Create to enter wizard 1 for creating a measurement job (as shown in Fig.2-61).

Fig. 2-61 Wizard 1 for creating a measurement job 1)


Page 508 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

After the settings are completed, click Next to enter wizard 2 for creating a measurement job (as shown in Fig.2-62).

Fig. 2-62 Wizard 2 for creating a measurement job Click Next to enter wizard 3 for creating a measurement job (as shown in Fig.2-63).

Fig. 2-63 Wizard 3 for creating a measurement job Click Next to enter wizard 4 for creating a measurement job (as shown in Fig.2-64).
Page 509 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-64 Wizard 4 for creating a measurement job 2.5.1.2 Observation job From the browse tree, select the observation job node of a BSS. Then the right part of the interface will display a list of all current observation jobs of the BSS (as shown in Fig.2-65).

Fig. 2-65 Display of observation jobs

Page 510 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

In Fig. 2-65, select Observation jobs from the left browse tree, and then click menu Performance management? Create to enter the dialog box for creating an observation job (as shown in Fig.2-66).

Fig. 2-66 Create observation job Click the OK button to complete the creation of the new observation job. If the job is created successfully, the system will give a prompt, and the newly created job will be added in the browse tree and observation job list. 2.5.2 Performance analyzer In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Performance management ? Performance analyzer to enter the main interface of performance analyzer (as shown in Fig.2-67).

Page 511 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-67 Main interface of performance analyzer Select menu Report ? Create performance report to enter the performance report wizard (as shown in Fig.2-68).

Fig. 2-68 Performance report wizard 1) Select the report type in this dialog box, and then click Next to enter the next wizard interface (as shown in Fig.2-69).

Page 512 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-69 Performance report wizard 2) Select the analysis object of the report, and then click Next to enter the next wizard interface (as shown in Fig.2-70).

Fig. 2-70 Performance report wizard 3) Click Finish to complete the parameter input. 2.5.3 Invoke tracing In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select Performance management? Invoke trace to enter the main interface of invoke trace (as shown in Fig.2-71).

Page 513 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-71 Main interface of invoke trace Select menu Trace? Start tracing. Then the workstation will initiate a handshake (communication) for invoke tracing with the BSC. If the MSC has already activated the BSC for invoke tracing via a message, then the BSC will also initiate a handshake to the workstation. If the handshake is successful, the tracing program will decode, classify and display the received tracing information. If the handshake is still unsuccessful after 1 minute, then it is regarded as a failure, and the system will instruct the user to end the tracing and re-initiate the tracing. After successful handshake, once there is any tracing message, the program will decode and display the message in real time (as shown in Fig.2-72).

Page 514 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-72 Display of invoke tracing messages By double-clicking a tracing message, a dialog box will pop up to display the detailed information of the tracing message, as shown in Fig.2-73.

Fig. 2-73 Detailed information of invoke tracing

Page 515 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

2.5.4

Signaling tracing In the main interface of OMCR (V2) (refer to Fig. 2-10 in volume 1), select System tools ? Signal trace to enter the main interface of signaling tracing, as shown in Fig.2-74.

Fig. 2-74 Main interface of signaling tracing Select menu Signal trace? Start to start a trace and enter the tracing configuration dialog box, which is as shown in Fig.2-75 in the GSM environment, and is as shown in Fig.2-76 in the GPRS environment.

Page 516 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-75 Tracing configurationGSM

Fig. 2-76 Tracing configurationGPRS First, select the BSC for signaling tracing from the pull-down list of BSCs, and then select the message type. Click the Confirm button to start signaling tracing, and the interface will display the traced messages in real time, as shown in Fig.2-77.
Page 517 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-77 Display of traced messages The message contents are displayed in the form of codes. You can double-click a traced message to view the detailed information of the message, as shown in Fig.2-78. Then a small window will appear at the lower part of the interface to display the detailed content of the selected tracing message.

Page 518 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Fig. 2-78 Display of detailed information

Page 519 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Appendix A Performance measurement counter


A.1
A.1.1

BTS performance measurement counter


Power control counter The power control counters are listed in table A-1. Table A-1 Power control counter

Counter No. C00001

Counter description The Number times for smooth Increase of MS Power due to Uplink Signal Level The Number of times for fast Increase of MS Power due to Uplink Signal Level The Number times for smooth Decrease of MS Power due to Uplink Signal Level The Number of times for fast Decrease of MS Power due to Uplink Signal Level The Number of times for smooth Increase of BS Power due to Downlink Signal Level The Number of times for fast Increase of BS Power due to Downlink Signal Level The Number of times for smooth Decrease of BS Power due to Downlink Signal Level The Number of times for fast Decrease of BS Power due to Downlink Signal Level The Number of times for smooth Increase of MS Power due to Uplink Signal Quality The Number of times for fast Increase of MS Power due to Uplink Signal Quality The Number of times for smooth Decrease of MS Power due to Uplink Signal Quality The Number of times for fast Decrease of MS Power due to Uplink Signal Quality The Number of times for smooth Increase of BS Power due to Downlink Signal Quality

Explanations

Source FUC

Unit TRX

C00002

FUC

TRX

C00003

FUC

TRX

C00004

FUC

TRX

C00005

FUC

TRX

C00006

FUC

TRX

C00007

FUC

TRX

C00008

FUC

TRX

C00009

FUC

TRX

C00010

FUC

TRX

C00011

FUC

TRX

C00012

FUC

TRX

C00013

FUC

TRX

Page 520 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C00014 Counter description The Number of times for fast Increase of BS Power due to Downlink Signal Quality The Number of times for smooth Decrease of BS Power due to Downlink Signal Quality The Number of times for fast Decrease of BS Power due to Downlink Signal Quality The total value of the regular scanned results of MS service power Number of sampling times for regular scanning of MS service power The total value of the regular scanned results of BS service power Number of sampling times for regular scanning of BS service power The total value of the regular scanned results of Downlink Signal Level Number of sampling times for regular scanning of Downlink Signal Level The total value of the regular scanned results of Uplink Signal Level Number of sampling times for regular scanning of Uplink Signal Level The total value of the regular scanned results of Downlink Signal Quality Number of sampling times for regular scanning of Downlink Signal Quality The total value of the regular scanned results of Uplink Signal Quality Number of sampling times for regular scanning of Uplink Signal Quality Explanations Source FUC Unit TRX

C00015

FUC

TRX

C00016

FUC

TRX

C00017

FUC

TRX

C00018

FUC

TRX

C00019

FUC

TRX

C00020

FUC

TRX

C00021

FUC

TRX

C00022

FUC

TRX

C00023

FUC

TRX

C00024

FUC

TRX

C00025

FUC

TRX

C00026

FUC

TRX

C00027

FUC

TRX

C00028

FUC

TRX

A.1.2

Paging counter The paging counters are listed in Table A-2. Table A-2 Paging counters
Page 521 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C01001 Counter description Counting the PS paging messages discarded due to queue being full Counting the CS paging messages discarded due to queue being full Average length of CH queue:9*9 Average length of PCH:9*64 Source FUC Unit TRX

C01002

FUC

TRX

C01003 C01004

FUC FUC

TRX TRX

A.2
A.2.1

RMM performance measurement counter


Radio access counter

This type of counters are mainly used to observe the wireless random access process of mobile stations, and used as the basis of radio access parameter adjustment and signaling channel allocation policy. Among them, several possible radio access reasons are listed in Table A-3. Table A-3 Radio access counter

Counter No. C10001

Counter description Number of invalid access requests Number of MOC access requests Number of successfully processed MOC access requests Number of successful MOC access times

Explanations Access delay is beyond the range of the cell, etc. The channel requirement of MOC is received Counted when immediate assignments are sent

Source RMS

Unit Cell

C10002

RMS

Cell

C10003

RMS

Cell

C10004

Counted when link setup instructions are received for immediate assignments The channel requirement of MTC is received Counted when immediate assignments are sent

RMS

Cell

C10005

Number of MTC access requests Number of successfully processed MTC access requests

RMS

Cell

C10006

RMS

Cell

Page 522 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10007 Counter description Number of successful M TC access times Explanations Counted when link setup instructions are received for immediate assignments The channel requirement of Call reestablishment is received Counted when immediate assignments are sent Source RMS Unit Cell

C10008

Number of Call Reestablishment access requests Number of successfully processed Call Reestablishment access requests Number of successful Call Reestablishment access times

RMS

Cell

C10009

RMS

Cell

C10010

Counted when link setup instructions are received for immediate assignments The channel requirement of emergency call is received Counted when immediate assignments are sent

RMS

Cell

C10011

Number of emergency call access requests Number of successfully processed emergency call access requests Number of successful emergency call access times

RMS

Cell

C10012

RMS

Cell

C10013

Counted when link setup instructions are received for immediate assignments The channel requirement of LOC is received Counted when immediate assignments are sent Counted when link setup instructions are received for immediate assignments Other channel requirements are received Counted when immediate assignments are sent Counted when link setup instructions are received for immediate assignments

RMS

Cell

C10014

Number of LOC access requests Number of successfully processed LOC access requests Number of successful LOC access times

RMS

Cell

C10015

RMS

Cell

C10016

RMS

Cell

C10017

Number of other access requests Number of successfully processed other access requests Number of successful other access times

RMS

Cell

C10018

RMS

Cell

C10019

RMS

Cell

Note: the number of access requests refers to the number of channel request messages received; and the number of successfully processed access requests refers to number of immediate assignments transmitted. Since in the SLOT-ALOHA protocols used by radio access, one access operation may include multiple access requests, the access success rate can be calculated and described by using the percentage of successfully
Page 523 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

processed access requests to the total access requests, and this value reflects the blocking decree of the signaling channel; while the percentage of successful access times to the total access requests reflects the collision condition of radio access requests. If this value is relatively low, then such factors as whether the time interval of access requests is reasonable need to be taken into account. A.2.2 SDCCH counter This type of counters are mainly used to describe the allocation, seizure, assignment and using of resources related to SDCCH, and serve as the basis for the configuration of SDCCH and the adjustment of related parameters, as listed in Table A-4. Table A-4 SDCCH counters

Counter No. C10101

Counter description SDCCH seizure attempt times (for assignment)

Explanations Applying for SDCCH from the database for immediate assignment Application from the database successful Application from the database unsuccessful Applying for SDCCH from the database for handover Application from the database successful Application from the database unsuccessful BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS

Source RMS

Unit Cell

C10102

SDCCH seizure success times (for assignment) SDCCH seizure failure times (for assignment) SDCCH seizure attempt times (for handover) SDCCH seizure success times (for handover) SDCCH seizure failure times (for handover) SDCCH allocation attempt times (for assignment) SDCCH allocation success times (for assignment) SDCCH allocation failure times (for assignment)

RMS

Cell

C10103

RMS

Cell

C10104

RMS

Cell

C10105

RMS

Cell

C10106

RMS

Cell

C10107

RMS

Cell

C10108

RMS

Cell

C10109

RMS

Cell

C10110

SDCCH allocation attempt times (for handover)

RMS

Cell

Page 524 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10111 Counter description SDCCH allocation success times (for handover) SDCCH allocation failure times (for handover) Explanations ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends immediate assignment messages EstablishIndication received Source RMS Unit Cell

C10112

RMS

Cell

C10113

SDCCH assignment attempt times SDCCH assignment success times SDCCH assignment failure times SDCCH handover attempt times

RMS

Cell

C10114

RMS

Cell

C10115

EstablishIndication not received Prepare for handover after receiving ChannelActivationAck AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions

RMS

Cell

C10116

RMS

Cell

C10117

SDCCH handover success times

RMS

Cell

C10118

SDCCH returned handover failure times SDCCH non-returned handover failure times

RMS

Cell

C10119

RMS

Cell

A.2.3

SAPI3 counter This type of counters are mainly used to describe the link establishment and load conditions of point-to-point messages, as listed in Table A-5. Table A-5 SAPI3 counters

Counter No. C10201

Counter description Number of SAPI3 link establishment times on SACCH/F (MO-SM) Number of SAPI3 link establishment times on SACCH/H (MO-SM) Number of SAPI3 link establishment times on SDCCH

Explanations An EstablishIndication message is received, and its SAPI=3 An EstablishIndication message is received, and its SAPI=3 An EstablishIndication message is received, and its

Source RMS

Unit Cell

C10202

RMS

Cell

C10203

RMS

Cell

Page 525 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description (MO-SM ) C10204 Number of SAPI3 link establishment times on FACCH/F (MO-SM) Number of SAPI3 link establishment times on FACCH/H (MO-SM) Number of SAPI3 link establishment requests on SACCH/F (MT-SM) Number of SAPI3 link establishment requests on SACCH/H (MT-SM) Number of SAPI3 link establishment requests on SDCCH (MT-SM) Number of SAPI3 link establishment requests on FACCH/F (MT-SM) Number of SAPI3 link establishment requests on FACCH/H (MT-SM) Number of SAPI3 link establishment success times on SACCH/F (MT-SM) Number of SAPI3 link establishment success times on SACCH/H (MT-SM) Number of SAPI3 link establishment success times on SDCCH (MT-SM) Number of SAPI3 link establishment success times on FACCH/F (MT-SM) Number of SAPI3 link establishment success times on FACCH/H (MT-SM) Number of DTAP messages used for point-to-point short messages in SDCCH uplink Number of DTAP messages used for point-to-point short messages in SDCCH downlink Number of DTAP messages used Explanations SAPI=3 An EstablishIndication message is received, and its SAPI=3 An EstablishIndication message is received, and its SAPI=3 SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent SMS is received, but no link has been established, then EstablishRequest is sent An EstablishConfirm message is received RMS Cell Source Unit

C10205

RMS

Cell

C10206

RMS

Cell

C10207

RMS

Cell

C10208

RMS

Cell

C10209

RMS

Cell

C10210

RMS

Cell

C10211

RMS

Cell

C10212

RMS

Cell

C10213

RMS

Cell

C10214

An EstablishConfirm message is received

RMS

Cell

C10215

An EstablishConfirm message is received

RMS

Cell

C10216

SMS messages from mobile stations are received

RMS

Cell

C10217

SMS messages from the network are received

RMS

Cell

C10218

SMS messages from mobile

RMS

Cell

Page 526 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description for point-to-point short messages in FACCH/F uplink C10219 Number of DTAP messages used for point-to-point short messages in FACCH/F downlink Number of DTAP messages used for point-to-point short messages in FACCH/H uplink Number of DTAP messages used for point-to-point short messages in FACCH/H downlink Number of DTAP messages used for point-to-point short messages in SACCH/F uplink Number of DTAP messages used for point-to-point short messages in SACCH/F downlink Number of DTAP messages used for point-to-point short messages in SACCH/H uplink Number of DTAP messages used for point-to-point short messages in SACCH/H downlink Explanations stations are received Source Unit

SMS messages from the network are received

RMS

Cell

C10220

SMS messages from mobile stations are received

RMS

Cell

C10221

SMS messages from the network are received

RMS

Cell

C10222

SMS messages from mobile stations are received

RMS

Cell

C10223

SMS messages from the network are received

RMS

Cell

C10224

SMS messages from mobile stations are received

RMS

Cell

C10225

SMS messages from the network are received

RMS

Cell

Note: here MO-SM refers to the mobile-originated short messages; MTSM refers to the mobile-terminated short messages. Since in conversation state, point-to-point short messages can be received, a mobile caller may also be the party who receives a short message. A.2.4 TCH/F counter This type of counters are mainly used to describe the allocation, seizure, assignment and using of resources related to TCH/F, as listed in Table A6.

Page 527 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Table A-6 TCH/F counters

Counter No. C10301

Counter description TCH/F seizure attempt times (signaling) (for assignment)

Explanations Applying for TCH/F from the database, for immediate assignment Application from the database successful Application from the database fails Applying for TCH/F from the database, for handover Application from the database successful Application from the database fails BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends immediate assignment messages EstablishIndication received

Source RMS

Unit Cell

C10302

TCH/F seizure success times (signaling) (for assignment) TCH/F seizure failure times (signaling) (for assignment) TCH/F seizure attempt times (signaling) (for handover) TCH/F seizure success times (signaling) (for handover) TCH/F seizure failure times (signaling) (for handover) TCH/F allocation attempt times (signaling) (for assignment) TCH/F allocation success times (signaling) (for assignment) TCH/F allocation failure times (signaling) (for assignment)

RMS

Cell

C10303

RMS

Cell

C10304

RMS

Cell

C10305

RMS

Cell

C10306

RMS

Cell

C10307

RMS

Cell

C10308

RMS

Cell

C10309

RMS

Cell

C10310

TCH/F allocation attempt times (signaling) (for handover) TCH/F allocation success times (signaling) (for handover) TCH/F allocation failure times (signaling) (for handover)

RMS

Cell

C10311

RMS

Cell

C10312

RMS

Cell

C10313

TCH/F assignment attempt times (signaling) TCH/F assignment success times (signaling) TCH/F assignment failure times (signaling) TCH/F handover attempt times (signaling)

RMS

Cell

C10314

RMS

Cell

C10315

EstablishIndication not received Prepare for handover after receiving ChannelActivationAck

RMS

Cell

C10316

RMS

Cell

Page 528 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10317 Counter description TCH/F handover success times (signaling) Explanations AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions Applying for TCH/F from the database, for assignment Application from the database successful Application from the database fails Applying for TCH/F from the database, for handover Application from the database successful Application from the database fails BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received Source RMS Unit Cell

C10318

TCH/F returned handover failure times (signaling) TCH/F non-returned handover failure times (signaling) TCH/F seizure attempt times (voice) (for assignment) TCH/F seizure success times (voice) (for assignment) TCH/F seizure failure times (voice) (for assignment) TCH/F seizure attempt times (voice) (for handover) TCH/F seizure success times (voice) (for handover) TCH/F seizure failure times (voice) (for handover) TCH/F allocation attempt times (voice version 1) (for assignment) TCH/F allocation success times (voice version 1) (for assignment) TCH/F allocation failure times (voice version 1) (for assignment)

RMS

Cell

C10319

RMS

Cell

C10320

RMS

Cell

C10321

RMS

Cell

C10322

RMS

Cell

C10323

RMS

Cell

C10324

RMS

Cell

C10325

RMS

Cell

C10326

RMS

Cell

C10327

RMS

Cell

C10328

RMS

Cell

C10329

TCH/F allocation attempt times (voice version 1) (for handover) TCH/F allocation success times (voice version 1) (for handover) TCH/F allocation failure times (voice version 1) (for handover)

RMS

Cell

C10330

RMS

Cell

C10331

RMS

Cell

C10332

TCH/F allocation attempt times (voice version 2) (for assignment) TCH/F allocation success times (voice version 2) (for assignment)

RMS

Cell

C10333

RMS

Cell

Page 529 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10334 Counter description TCH/F allocation failure times (voice version 2) (for assignment) Explanations ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends AssignCommand to BTS AssignmentComplete received AssignmentComplete not received Prepare for handover after receiving ChannelActivationAck AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure Source RMS Unit Cell

C10335

TCH/F allocation attempt times (voice version 2) (for handover) TCH/F allocation success times (voice version 2) (for handover) TCH/F allocation failure times (voice version 2) (for handover)

RMS

Cell

C10336

RMS

Cell

C10337

RMS

Cell

C10338

TCH/F allocation attempt times (voice version 3) (for assignment) TCH/F allocation success times (voice version 3) (for assignment) TCH/F allocation failure times (voice version 3) (for assignment)

RMS

Cell

C10339

RMS

Cell

C10340

RMS

Cell

C10341

TCH/F allocation attempt times (voice version 3) (for handover) TCH/F allocation success times (voice version 3) (for handover) TCH/F allocation failure times (voice version 3) (for handover)

RMS

Cell

C10342

RMS

Cell

C10343

RMS

Cell

C10344

TCH/F assignment attempt times (voice) TCH/F assignment success times (voice) TCH/F assignment failure times (voice) TCH/F handover attempt times (voice)

RMS

Cell

C10345

RMS

Cell

C10346

RMS

Cell

C10347

RMS

Cell

C10348

TCH/F handover success times (voice)

RMS

Cell

C10349

TCH/F returned handover failure

RMS

Cell

Page 530 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description times (voice) C10350 TCH/F non-returned handover failure times (voice) TCH/F seizure attempt times (data) (for assignment) Explanations received Handover failure in other conditions Applying for TCH/F from the database, for assignment. Application from the database successful Application from the database fails Applying for TCH/F from the database, for handover Application from the database successful Application from the database fails BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends AssignCommand to BTS AssignmentComplete received AssignmentComplete not received Prepare for handover after receiving ChannelActivationAck RMS Cell Source Unit

C10351

RMS

Cell

C10352

TCH/F seizure success times (data) (for assignment) TCH/F seizure failure times (data) (for assignment) TCH/F seizure attempt times (data) (for handover) TCH/F seizure success times (data) (for handover) TCH/F seizure failure times (data) (for handover) TCH/F allocation attempt times (data) (for assignment) TCH/F allocation success times (data) (for assignment) TCH/F allocation failure times (data) (for assignment)

RMS

Cell

C10353

RMS

Cell

C10354

RMS

Cell

C10355

RMS

Cell

C10356

RMS

Cell

C10357

RMS

Cell

C10358

RMS

Cell

C10359

RMS

Cell

C10360

TCH/F allocation attempt times (data) (for handover) TCH/F allocation success times (data) (for handover) TCH/F allocation failure times (data) (for handover)

RMS

Cell

C10361

RMS

Cell

C10362

RMS

Cell

C10363

TCH/F assignment attempt times (data) TCH/F assignment success times (data) TCH/F assignment failure times (data) TCH/F handover attempt times (data)

RMS

Cell

C10364

RMS

Cell

C10365

RMS

Cell

C10366

RMS

Cell

Page 531 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10367 Counter description TCH/F handover success times (data) Explanations AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions Source RMS Unit Cell

C10368

TCH/F returned handover failure times (data) TCH/F non-returned handover failure times (data)

RMS

Cell

C10369

RMS

Cell

A.2.5

TCH/H counter This type of counters are mainly used to describe the allocation, seizure, assignment and using of resources related to TCH/H, as listed in Table A7. Table 2-7 TCH/H counter

Counter No.

Counter description

Explanations

Sourc e RMS

Unit

C10401

TCH/H seizure attempt times (signaling) (for assignment)

Applying for TCH/H from the database, for immediate assignment Application from the database successful Application from the database fails Applying for TCH/H from the database, for handover Application from the database successful Application from the database fails BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not

Cell

C10402

TCH/H seizure success times (signaling) (for assignment) TCH/H seizure failure times (signaling) (for assignment) TCH/H seizure attempt times (signaling) (for handover) TCH/H seizure success times (signaling) (for handover) TCH/H seizure failure times (signaling) (for handover) TCH/H allocation attempt times (signaling) (for assignment) TCH/H allocation success times (signaling) (for assignment) TCH/H allocation failure times (signaling) (for assignment)

RMS

Cell

C10403

RMS

Cell

C10404

RMS

Cell

C10405

RMS

Cell

C10406

RMS

Cell

C10407

RMS

Cell

C10408

RMS

Cell

C10409

RMS

Cell

Page 532 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Explanations received C10410 TCH/H allocation attempt times (signaling) (for handover) TCH/H allocation success times (signaling) (for handover) TCH/H allocation failure times (signaling) (for handover) BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends immediate assignment messages EstablishIndication received EstablishIndication not received Prepare for handover after receiving ChannelActivationAck AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions Applying for TCH/H from the database, for assignment Application from the database successful Application from the database fails Applying for TCH/H from the database, for handover Application from the database successful Application from the database fails RMS Cell Sourc e Unit

C10411

RMS

Cell

C10412

RMS

Cell

C10413

TCH/H assignment attempt times (signaling) TCH/H assignment success times (signaling) TCH/H assignment failure times (signaling) TCH/H handover attempt times (signaling)

RMS

Cell

C10414

RMS

Cell

C10415

RMS

Cell

C10416

RMS

Cell

C10417

TCH/H handover success times (signaling)

RMS

Cell

C10418

TCH/H returned handover failure times (signaling) TCH/H non-returned handover failure times (signaling) TCH/H seizure attempt times (voice) (for assignment)

RMS

Cell

C10419

RMS

Cell

C10420

RMS

Cell

C10421

TCH/H seizure success times (voice) (for assignment) TCH/H seizure failure times (voice) (for assignment) TCH/H seizure attempt times (voice) (for handover) TCH/H seizure success times (voice) (for handover) TCH/H seizure failure times (voice) (for handover)

RMS

Cell

C10422

RMS

Cell

C10423

RMS

Cell

C10424

RMS

Cell

C10425

RMS

Cell

Page 533 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Explanations Sourc e RMS Unit

C10426

TCH/H allocation attempt times (voice version 1) (for assignment) TCH/H allocation success times (voice version 1) (for assignment) TCH/H allocation failure times (voice version 1) (for assignment)

BSC sends ChannelActivation to BTS

Cell

C10427

ChannelActivationAck received

RMS

Cell

C10428

ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS

RMS

Cell

C10429

TCH/H allocation attempt times (voice version 1) (for handover) TCH/H allocation success times (voice version 1) (for handover) TCH/H allocation failure times (voice version 1) (for handover)

RMS

Cell

C10430

RMS

Cell

C10431

RMS

Cell

C10432

TCH/H allocation attempt times (voice version 2) (for assignment) TCH/H allocation success times (voice version 2) (for assignment) TCH/H allocation failure times (voice version 2) (for assignment)

RMS

Cell

C10433

ChannelActivationAck received

RMS

Cell

C10434

ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS

RMS

Cell

C10435

TCH/H allocation attempt times (voice version 2) (for handover) TCH/H allocation success times (voice version 2) (for handover) TCH/H allocation failure times (voice version 2) (for handover)

RMS

Cell

C10436

RMS

Cell

C10437

RMS

Cell

C10438

TCH/H allocation attempt times (voice version 3) (for assignment) TCH/H allocation success times (voice version 3) (for assignment) TCH/H allocation failure times (voice version 3) (for

RMS

Cell

C10439

ChannelActivationAck received

RMS

Cell

C10440

ChannelActivationNack received or

RMS

Cell

Page 534 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description assignment) Explanations ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends AssignCommand to BTS AssignmentComplete received AssignmentComplete not received Prepare for handover after receiving ChannelActivationAck AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions Applying for TCH/H from the database, for assignment. Application from the database successful Application from the database fails Applying for TCH/H from the database, for handover Application from the database successful Application from the database fails RMS Cell Sourc e Unit

C10441

TCH/H allocation attempt times (voice version 3) (for handover) TCH/H allocation success times (voice version 3) (for handover) TCH/H allocation failure times (voice version 3) (for handover)

C10442

RMS

Cell

C10443

RMS

Cell

C10444

TCH/H assignment attempt times (voice) TCH/H assignment success times (voice) TCH/H assignment failure times (voice) TCH/H handover attempt times (voice)

RMS

Cell

C10445

RMS

Cell

C10446

RMS

Cell

C10447

RMS

Cell

C10448

TCH/H handover success times (voice)

RMS

Cell

C10449

TCH/H returned handover failure times (voice) TCH/H non-returned handover failure times (voice) TCH/H seizure attempt times (data) (for assignment)

RMS

Cell

C10450

RMS

Cell

C10451

RMS

Cell

C10452

TCH/H seizure success times (data) (for assignment) TCH/H seizure failure times (data) (for assignment) TCH/H seizure attempt times (data) (for handover) TCH/H seizure success times (data) (for handover) TCH/H seizure failure times (data) (for handover)

RMS

Cell

C10453

RMS

Cell

C10454

RMS

Cell

C10455

RMS

Cell

C10456

RMS

Cell

Page 535 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Explanations Sourc e RMS Unit

C10457

TCH/H allocation attempt times (data) (for assignment) TCH/H allocation success times (data) (for assignment) TCH/H allocation failure times (data) (for assignment)

BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends ChannelActivation to BTS ChannelActivationAck received ChannelActivationNack received or ChannelActivationAck not received BSC sends AssignCommand to BTS AssignmentComplete received AssignmentComplete not received Prepare for handover after receiving ChannelActivationAck AssignComplete is received in intra-cell handover, HandoverComplete is received in inter-cell handover, Um_HandoverFailure received Handover failure in other conditions

Cell

C10458

RMS

Cell

C10459

RMS

Cell

C10460

TCH/H allocation attempt times (data) (for handover) TCH/H allocation success times (data) (for handover) TCH/H allocation failure times (data) (for handover)

RMS

Cell

C10461

RMS

Cell

C10462

RMS

Cell

C10463

TCH/H assignment attempt times (data) TCH/H assignment failure times (data) TCH/H assignment success times (data) TCH/H handover attempt times (data)

RMS

Cell

C10464

RMS

Cell

C10465

RMS

Cell

C10466

RMS

Cell

C10467

TCH/H handover success times (data)

RMS

Cell

C10468

TCH/H returned handover failure times (data) TCH/H non-returned handover failure times (data)

RMS

Cell

C10469

RMS

Cell

A.2.6

RMM assignment counter This type of counters describes the assignment process of RMM. In an assignment operation, multiple attempts are allowable if the channel can not be applied for, so the whole assignment process must be described completely, and it is insufficient to only describe the assignment process
Page 536 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

on TCH/F or TCH/H. These counters can be used to judge how forced release, queuing and directional retry contribute to the success rate of assignment from the view point of calls, as listed in Table A-8. Table 2-8 RMM assignment counter

Counter No. C10501

Counter description Number of times for execution of general assignments (voice)

Explanations Without such processing as queuing and directional retry, the criterion is whether an Assign Command is sent. As to the next process, it is described by the assignment counter of TCH When no channel can be applied for from the database, a channel with lower priority level is released by force. Forced release of the channel is successful, and the desired channel is acquired. When no channel can be applied for from the database, the system queues for the release of resources Queuing is successful, and the desired channel is acquired.

Source RM S

Unit Cell

C10502

Number of times for forced release attempt of assignment (voice)

RMS

Cell

C10503

Number of times for execution of assignments due to forced release (voice) Number of times for queuing attempt of assignment (voice)

RMS

Cell

C10504

RMS

Cell

C10505

Number of times for execution of assignments due to queuing (voice) Total time length of successful assignment queuing (voice) Number of successful times for assignment queuing (voice) Number of times for directional retry attempt of assignment (voice) Number of times for execution of assignments due to directional retry (voice) Number of times for execution of general assignments (data)

RMS

Cell

C10506

The total amount of time taken for queuing Number of times for successful queuing When no channel can be applied for from the database, directional retry is performed Directional retry is successful, and the desired channel is acquired. Without such processing as queuing and directional retry, the criterion is whether an Assign Command is sent. As to the next process, it is described by the assignment counter of TCH When no channel can be applied for from the database,

RMS

Cell

C10507

RMS

Cell

C10508

RMS

Cell

C10509

RMS

Cell

C10510

RMS

Cell

C10511

Number of times for forced release attempt of assignment

RMS

Cell

Page 537 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description (data) Explanations a channel with lower priority level is released by force. Forced release of the channel is successful, and the desired channel is acquired. When no channel can be applied for from the database, the system queues for the release of resources Queuing is successful, and the desired channel is acquired. RMS Cell Source Unit

C10512

Number of times for execution of assignments due to forced release (data) Number of times for queuing attempt of assignment (data)

C10513

RMS

Cell

C10514

Number of times for execution of assignments due to queuing (data) Total time length of successful assignment queuing (data)

RMS

Cell

C10515

The total amount of time taken for successful assignment queuing Number of times for successful queuing When no channel can be applied for from the database, directional retry is performed Directional retry is successful, and the desired channel is acquired.

RMS

Cell

C10516

Number of successful times for assignment queuing (data) Number of times for directional retry attempt of assignment (data) Number of times for execution of assignments due to directional retry (data)

RMS

Cell

C10517

RMS

Cell

C10518

RMS

Cell

A.2.7

RMM call drop counter This type of counters is used for statistics of various call drop conditions, for the convenience of fault diagnosis, as listed in Table A-9. Table A-9 RMM call drop counter

Counter No. C10601

Counter description Number of failures due to losing contact with SMM (On SDCCH) Number of wireless link failures (On SDCCH) Number of LAPD link failures (On SDCCH) Number of forced release times by OMC-R (On SDCCH)

Explanations No response from SMM until timeout Abis_ConnectFailInd is received LAPD Release is received

Source RMS

Unit Cell

C10602

RMS

Cell

C10603

RMS

Cell

C10604

OMS_ForcedRelease is received

RMS

Cell

Page 538 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10605 Counter description Number of forced release times by other calls (On SDCCH) Number of other call drop times (On SDCCH) Number of failures due to losing contact with SMM (On TCH/F signaling) Number of wireless link failures (On TCH/F signaling) Number of LAPD link failures (On TCH/F signaling) Number of forced release times by OMC-R (On TCH/F signaling) Number of forced release times by other calls (On TCH/F signaling) Number of other call drop times (On TCH/F signaling) Number of failures due to losing contact with SMM (On TCH/F voice) Number of wireless link failures (On TCH/F voice) Number of LAPD link failures (On TCH/F voice) Number of forced release times by OMC-R (On TCH/F voice) Number of forced release times by other calls (On TCH/F voice) Number of other call drop times (On TCH/F voice) Number of failures due to losing contact with SMM (On TCH/F data) Number of wireless link failures (On TCH/F data) Number of LAPD link failures (On TCH/F data) Number of forced release times by OMC-R (On TCH/F data) Explanations Preemptive is received Source RMS Unit Cell

C10606

Call drop due to other reasons No response from SMM until timeout

RMS

Cell

C10607

RMS

Cell

C10608

Abis_ConnectFailInd is received LAPD Release is received

RMS

Cell

C10609

RMS

Cell

C10610

OMS_ForcedRelease is received Preemptive is received

RMS

Cell

C10611

RMS

Cell

C10612

Call drop due to other reasons No response from SMM until timeout

RMS

Cell

C10613

RMS

Cell

C10614

Abis_ConnectFailInd is received LAPD Release is received

RMS

Cell

C10615

RMS

Cell

C10616

OMS_ForcedRelease is received Preemptive is received

RMS

Cell

C10617

RMS

Cell

C10618

Call drop due to other reasons No response from SMM until timeout

RMS

Cell

C10619

RMS

Cell

C10620

Abis_ConnectFailInd is received LAPD Release is received

RMS

Cell

C10621

RMS

Cell

C10622

OMS_ForcedRelease is received

RMS

Cell

Page 539 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10623 C10624 Counter description Number of forced release times by other calls (On TCH/F data) Number of other call drop times (On TCH/F data) Number of failures due to losing contact with SMM (On TCH/H signaling) Number of wireless link failures (On TCH/H signaling) Number of LAPD link failures (On TCH/H signaling) Number of forced release times by OMC-R (On TCH/H signaling) Number of forced release times by other calls (On TCH/H signaling) Number of other call drop times (On TCH/H signaling) Number of failures due to losing contact with SMM (On TCH/H voice) Number of wireless link failures (On TCH/H voice) Number of LAPD link failures (On TCH/H voice) Number of forced release times by OMC-R (On TCH/H voice) Number of forced release times by other calls (On TCH/H voice) Number of other failure times (On TCH/H voice) Number of failures due to losing contact with SMM (On TCH/H data) Number of wireless link failures (On TCH/H data) Number of LAPD link failures (On TCH/H data) Number of forced release times by OMC-R (On TCH/H data) Number of forced release times by other calls (On TCH/H data) Explanations Preemptive is received Call drop due to other reasons No response from SMM until timeout Abis_ConnectFailInd is received LAPD Release is received OMS_ForcedRelease is received Preemptive is received Source RMS RMS Unit Cell Cell

C10625

RMS

Cell

C10626

RMS

Cell

C10627 C10628

RMS RMS

Cell Cell

C10629

RMS

Cell

C10630 C10631

Call drop due to other reasons No response from SMM until timeout

RMS RMS

Cell Cell

C10632

Abis_ConnectFailInd is received LAPD Release is received

RMS

Cell

C10633

RMS

Cell

C10634

OMS_ForcedRelease is received Preemptive is received

RMS

Cell

C10635

RMS

Cell

C10636

Call drop due to other reasons No response from SMM until timeout

RMS

Cell

C10637

RMS

Cell

C10638

Abis_ConnectFailInd is received LAPD Release is received

RMS

Cell

C10639

RMS

Cell

C10640

OMS_ForcedRelease is received Preemptive is received

RMS

Cell

C10641

RMS

Cell

Page 540 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10642 Counter description Number of other call drop times (On TCH/H data) Number of SDCCH call drop times Explanations Call drop due to other reasons Call loss due to wireless reasons after successful assignment Call loss due to wireless reasons after successful assignment Call loss due to wireless reasons after successful assignment No HoCom or AssigCom message is received until timeout RMS Source RMS Unit Cell

C10643

Cell

C10644

Number of TCH/F call drop times

Cell

C10645

Number of TCH/H call drop times

RMS

Cell

C10646

Call drop due to handover failure

RMS

Cell

Note: These counters take statistics for various call drop conditions, so as to facilitate fault diagnosis.

A.2.8

Radio measurement counter These parameters reflect the interference and service quality of channels in seizure and idle states. Ordinary measurement reports and preprocessing measurement reports are handled in the same way, as listed in Table A-10. Table A-10 Radio measurement counters

Counter No. C10701

Counter description Number of uplink quality samples on radio channel

Explanations Counted when measurement reports are received or preprocessed. The same below.

Source RMS

Unit Cell

C10702 C10703

The worst uplink quality level on radio channel The total number of uplink quality levels on radio channel Number of downlink quality samples on radio channel The worst downlink quality level on radio channel The total number of downlink

RMS RMS

Cell Cell

C10704 C10705

RMS RMS

Cell Cell

C10706

RMS

Cell

Page 541 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description quality levels on radio channel C10707 Number of uplink receiving intensity samples on radio channel The highest uplink receiving intensity on radio channel The lowest uplink receiving intensity on radio channel The total number of uplink receiving intensities on radio channel Number of downlink receiving intensity samples on radio channel The highest downlink receiving intensity on radio channel The lowest downlink receiving intensity on radio channel The total number of downlink receiving intensities on radio channel Number of TA samples on radio channel Maximum TA of radio channel Total number of radio channel TAs The average number of available TCH/Fs in interference band 0 The average number of available TCH/Fs in interference band 1 Call the database interface to query resource conditions according to the cell No. The same below. RMS Cell Explanations Source Unit

C10708

RMS

Cell

C10709

RMS

Cell

C10710

RMS

Cell

C10711

RMS

Cell

C10712

RMS

Cell

C10713

RMS

Cell

C10714

RMS

Cell

C10715

RMS

Cell

C10716 C10717 C10718

RMS RMS DBS

Cell Cell Cell

C10719

DBS

Cell

C10720

The average number of available TCH/Fs in interference band 2 The average number of available TCH/Fs in interference band 3 The average number of available TCH/Fs in interference band 4 The average number of available TCH/Fs in interference band 5 The average number of available TCH/Hs in interference band 0

DBS

Cell

C10721

DBS

Cell

C10722

DBS

Cell

C10723

DBS

Cell

C10724

DBS

Cell

Page 542 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10725 Counter description The average number of available TCH/Hs in interference band 1 The average number of available TCH/Hs in interference band 2 The average number of available TCH/Hs in interference band 3 The average number of available TCH/Hs in interference band 4 The average number of available TCH/Hs in interference band 5 The average number of available SDCCHs in interference band 0 The average number of available SDCCHs in interference band 1 The average number of available SDCCHs in interference band 2 The average number of available SDCCHs in interference band 3 The average number of available SDCCHs in interference band 4 The average number of available SDCCHs in interference band 5 Explanations Source DBS Unit Cell

C10726

DBS

Cell

C10727

DBS

Cell

C10728

DBS

Cell

C10729

DBS

Cell

C10730

DBS

Cell

C10731

DBS

Cell

C10732

DBS

Cell

C10733

DBS

Cell

C10734

DBS

Cell

C10735

DBS

Cell

Note: These parameters reflect the interference and service quality of channels in seized and idle states. Ordinary measurement reports and preprocessing measurement reports are handled in the same way

A.2.9

Handover reason counter

This type of counters is used to count the number of handover attempts due to various reasons. Since handover generally happens only in necessary conditions, these data are quite significant to the appraisement of network service quality, as listed in Table A-11. Table A-11 Handover reason counters

Counter No.

Counter description

Explanations

Source Unit

Page 543 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10801 Counter description Handover attempt due to directional retry Explanations No channel can be applied for during assignment, so directional retry is performed. The handover is due to high uplink bit error rate or low uplink level The handover is due to high downlink bit error rate or low downlink level Because of uplink interference Because of downlink interference Because of concentric circle handover to STRX or to NTRX Boundary handover due to PBGT value Because the distance between MS and the network is too long E.g., handover attempts due to interrogation of handover candidates Handover triggered due to traffic The handover is due to other reasons, such as fast fading and macro/micro handover, etc. The handover is due to high uplink bit error rate or low uplink level The handover is due to high downlink bit error rate or low downlink level Because of uplink interference Because of downlink interference Because of concentric circle handover to STRX or to Source Unit RMS Cell

C10802

Handover attempt due to uplink receiving intensity (on SDCCH)

RMS

Cell

C10803

Handover attempt due to downlink receiving intensity (on SDCCH)

RMS

Cell

C10804

Handover attempt due to uplink interference (on SDCCH) Handover attempt due to downlink interference (on SDCCH) Handover attempt due to C/I (on SDCCH)

RMS

Cell

C10805

RMS

Cell

C10806

RMS

Cell

C10807

Handover attempt due to PBGT (on SDCCH) Handover attempt due to TA being too large (on SDCCH)

RMS

Cell

C10808

RMS

Cell

C10809

Handover attempt due to MSC request (on SDCCH)

RMS

Cell

C10810

Handover attempt due to traffic (on SDCCH) Handover attempt due to other reasons (on SDCCH)

RMS

Cell

C10811

RMS

Cell

C10812

Handover attempt due to uplink receiving intensity (on TCH/F)

RMS

Cell

C10813

Handover attempt due to downlink receiving intensity (on TCH/F)

RMS

Cell

C10814

Handover attempt due to uplink interference (on TCH/F) Handover attempt due to downlink interference (on TCH/F) Handover attempt due to C/I (on TCH/F)

RMS

Cell

C10815

RMS

Cell

C10816

RMS

Cell

Page 544 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Explanations NTRX C10817 Handover attempt due to PBGT (on TCH/F) Handover attempt due to TA being too large (on TCH/F) Boundary handover due to PBGT value Because the distance between MS and the network is too long E.g., handover attempts due to interrogation of handover candidates Handover triggered due to traffic The handover is due to other reasons, such as fast fading and macro/micro handover, etc. The handover is due to high uplink bit error rate or low uplink level The handover is due to high downlink bit error rate or low downlink level Because of uplink interference Because of downlink interference Because of concentric circle handover to STRX or to NTRX Boundary handover due to PBGT value Because the distance between MS and the network is too long E.g., handover attempts due to interrogation of handover candidates Handover triggered due to traffic The handover is due to other reasons, such as fast fading and macro/micro handover, etc. RMS Cell Source Unit

C10818

RMS

Cell

C10819

Handover attempt due to MSC request (on TCH/F)

RMS

Cell

C10820

Handover attempt due to traffic (on TCH/F) Handover attempt due to other reasons (on TCH/F)

RMS

Cell

C10821

RMS

Cell

C10822

Handover attempt due to uplink receiving intensity (on TCH/H)

RMS

Cell

C10823

Handover attempt due to downlink receiving intensity (on TCH/H)

RMS

Cell

C10824

Handover attempt due to uplink interference (on TCH/H) Handover attempt due to downlink interference (on TCH/H) Handover attempt due to C/I (on TCH/H)

RMS

Cell

C10825

RMS

Cell

C10826

RMS

Cell

C10827

Handover attempt due to PBGT (on TCH/H) Handover attempt due to TA being too large (on TCH/H)

RMS

Cell

C10828

RMS

Cell

C10829

Handover attempt due to MSC request (on TCH/H)

RMS

Cell

C10830

Handover attempt due to traffic (on TCH/H) Handover attempt due to other reasons (on TCH/H)

RMS

Cell

C10831

RMS

Cell

Page 545 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10832 Counter description Handover attempt due to enlarging of TA in expansion cell (on TCH/F) Handover attempt due to diminishing of TA in expansion cell (on TCH/F) Explanations The enlarging of TA causes switchover from normal carrier to expanded carrier The diminishing of TA causes switchover from expanded carrier to normal carrier Source Unit RMS Cell

RMS

Cell

C10833

A.2.10

General counter of handover This type of counters is mainly used to check the handover status, and the objective is to distinguish inner and outer circles, levels and frequency bands, and the controlling side, as listed in Table A-12. In the table, both BSC handover and MSC handover refer to inter-cell handover. Table A-12 General counter of handover

Counter No. C10901

Counter description The Number of BSCcontrolled Inter-cell Outgoing Handover Attempts The Number of times for execution of BSC-controlled Inter-cell Outgoing Handover The Number of Successful BSC-controlled inter-cell Outgoing Handovers The Number of MSCcontrolled Outgoing Handover Attempts

Explanations Counted when handover is necessary after a measurement report or pre-processing measurement report is received. After the application of resources to the target instance is successful The Handover Complete message from the target instance is received Counted when handover is necessary after a measurement report or pre-processing measurement report is received. A handover request is sent to MSC after the interrogation of MSC handover candidates is received

Source RMS

Unit Cell

C10902

RMS

Cell

C10903

RMS

Cell

C10904

RMS

Cell

C10905

The Number of MSCcontrolled Outgoing Handover Request Failures due to unknown reasons The Number of MSCcontrolled Outgoing Handover Request Failures due to no available land resources The Number of MSCcontrolled Outgoing Handover Request Failures due to no

T7 timeout (possibly HO Require does not use the response request unit) The received handover request is rejected

RMS

Cell

C10906

RMS

Cell

C10907

The received handover request is rejected

RMS

Cell

Page 546 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description available radio resources C10908 The Number of MSCcontrolled Outgoing Handover Request Failures due to other reasons The Number of times for execution of M SC-controlled Outgoing Handover The Number of Successful MSC-controlled Outgoing Handovers The Number of BSCcontrolled Inter-cell Incoming Handover Attempts The Number of times for execution of BSC-controlled Inter-cell Incoming Handover The Number of Successful BSC-controlled inter-cell Incoming Handovers The Number of MSCcontrolled Incoming Handover Attempts The Number of times for execution of MSC-controlled Incoming Handover (general) The Number of Forced Release Attempts of MSCcontrolled Incoming Handover The Number of times for execution of MSC-controlled Incoming Handover (forced release) The Number of Queuing Attempts of MSC-controlled Incoming Handover The Number of times for execution of MSC-controlled Incoming Handover (queuing) The Number of Successful MSC-controlled Incoming Handovers The total queuing time of MSC-controlled Incoming Handover The Number of MSCcontrolled Incoming Handover Queues The received handover request is rejected. Device failure, invalid message, etc. Counted if Handover Command is sent Counted if the reason value in the received Clear Command message is successful handover The target instance receives the RadioApply message due to intra-cell handover Resources have been requested successfully, and the RadioAvailable message is returned to the source instance The Handover Complete message has been received from MS The total number of received handover attempts Resources have been requested successfully from the database When no channel can be applied for from the database, a channel with lower priority level is released by force. Forced release of the channel is successful, and the desired channel is acquired. When no channel can be applied for from the database, the system queues for the release of resources Queuing is successful, and the desired channel is acquired. Handover Complete received RMS Cell RMS Cell Explanations Source Unit

C10909

C10910

RMS

Cell

C10911

RMS

Cell

C10912

RMS

Cell

C10913

RMS

Cell

C10914

RMS

Cell

C10915

RMS

Cell

C10916

RMS

Cell

C10917

RMS

Cell

C10918

RMS

Cell

C10919

RMS

Cell

C10920

RMS

Cell

C10921

The total amount of time taken for queuing in incoming handover The Number of Incoming Handover Queues

RMS

Cell

C10922

RMS

Cell

Page 547 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10923 Counter description The Total queuing time of Successful MSC-controlled Incoming Handover The Number of Successful MSC-controlled Incoming Handover Queues Number of incoming handover attempts from the same layer and the same frequency band Number of successful incoming handovers from the same layer and the same frequency band Number of outgoing handover attempts to the same layer and the same frequency band Number of successful outgoing handovers to the same layer and the same frequency band Number of incoming handover attempts from a undefined layer and the same frequency band Number of successful incoming handovers from a undefined layer and the same frequency band Number of outgoing handover attempts to a undefined layer and the same frequency band Number of successful outgoing handovers to a undefined layer and the same frequency band Number of incoming handover attempts from a undefined layer (GSM 900? GSM 1800) Number of incoming handovers from a undefined layer (GSM 900? GSM 1800) Number of successful incoming handovers from a undefined layer (GSM 900? GSM 1800) Number of outgoing handover attempts to a undefined layer RMS Cell Explanations The total amount of time taken for queuing of successful incoming handover Number of times for successful queuing of incoming handover Source RMS Unit Cell

C10924

RMS

Cell

C10925

RMS

Cell

C10926

RMS

Cell

C10927

RMS

Cell

C10928

RMS

Cell

C10929

RMS

Cell

C10930

RMS

Cell

C10931

RMS

Cell

C10932

RMS

Cell

C10933

RMS

Cell

C10934

C10935

C10936

RMS

Cell

Page 548 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description (GSM 900? GSM 1800) C10937 Number of successful outgoing handovers to a undefined layer (GSM 900? GSM 1800) Number of incoming handover attempts from a undefined layer (GSM 1800? GSM 900) Number of incoming handovers from a undefined layer (GSM 1800? GSM 900) Number of successful incoming handovers from a undefined layer (GSM 1800? GSM 900) Number of outgoing handover attempts to a undefined layer (GSM 1800? GSM 900) Number of successful outgoing handovers to a undefined layer (GSM 1800? GSM 900) Number of incoming handover attempts from the upper layer and the same frequency band Number of successful incoming handovers from the upper layer and the same frequency band Number of outgoing handover attempts to the upper layer and the same frequency band Number of successful outgoing handovers to the upper layer and the same frequency band Number of incoming handover attempts from the lower layer and the same frequency band Number of successful incoming handovers from the lower layer and the same frequency band Number of outgoing handover attempts to the lower layer and the same frequency band RMS Cell Explanations Source Unit

C10938

RMS

Cell

C10939

RMS

Cell

C10940

RMS

Cell

C10941

RMS

Cell

C10942

RMS

Cell

C10943

RMS

Cell

C10944

RMS

Cell

C10945

RMS

Cell

C10946

RMS

Cell

C10947

RMS

Cell

C10948

RM S

Cell

C10949

RMS

Cell

Page 549 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10950 Counter description Number of successful outgoing handovers to the lower layer and the same frequency band Number of incoming handover attempts from the same layer and a different frequency band (GSM 900? GSM 1800) Number of incoming handovers from the same layer and a different frequency band (GSM 900? GSM 1800) Number of successful incoming handovers from the same layer and a different frequency band (GSM 900? GSM 1800) Number of outgoing handover attempts to the same layer and a different frequency band (GSM 900? GSM 1800) Number of successful outgoing handovers to the same layer and a different frequency band (GSM 900? GSM 1800) Number of incoming handover attempts from the upper layer and a different frequency band (GSM 900? GSM 1800) Number of incoming handovers from the upper layer and a different frequency band (GSM 900? GSM 1800) Number of successful incoming handovers from the upper layer and a different frequency band (GSM 900? GSM 1800) Number of outgoing handover attempts to the upper layer and a different frequency band (GSM 900? GSM 1800) Number of successful outgoing handovers to the upper layer and a different frequency band (GSM 900? GSM 1800) Explanations Source RMS Unit Cell

C10951

RMS

Cell

C10952

RMS

Cell

C10953

RMS

Cell

C10954

RMS

Cell

C10955

RMS

Cell

C10956

RMS

Cell

C10957

RMS

Cell

C10958

RMS

Cell

C10959

RMS

Cell

C10960

RMS

Cell

Page 550 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10961 Counter description Number of incoming handover attempts from the lower layer and a different frequency band (GSM 900? GSM 1800) Number of incoming handovers from the lower layer and a different frequency band (GSM 900? GSM 1800) Number of successful incoming handovers from the lower layer and a different frequency band (GSM 900? GSM 1800) Number of outgoing handover attempts to the lower layer and a different frequency band (GSM 900? GSM 1800) Number of successful outgoing handovers to the lower layer and a different frequency band (GSM 900? GSM 1800) Number of incoming handover attempts from the same layer and a different frequency band (GSM 1800? GSM 900) Number of incoming handovers from the same layer and a different frequency band (GSM 1800? GSM 900) Number of successful incoming handovers from the same layer and a different frequency band (GSM 1800? GSM 900) Number of outgoing handover attempts to the same layer and a different frequency band (GSM 1800? GSM 900) Number of successful outgoing handovers to the same layer and a different frequency band (GSM 1800? GSM 900) Number of incoming handover attempts from the upper layer and a different frequency band (GSM 1800? GSM 900) Explanations Source RMS Unit Cell

C10962

RMS

Cell

C10963

RMS

Cell

C10964

RMS

Cell

C10965

RMS

Cell

C10966

RMS

Cell

C10967

RMS

Cell

C10968

RMS

Cell

C10969

RMS

Cell

C10970

RMS

Cell

C10971

RMS

Cell

Page 551 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10972 Counter description Number of incoming handovers from the upper layer and a different frequency band (GSM 1800? GSM 900) Number of successful incoming handovers from the upper layer and a different frequency band (GSM 1800? GSM 900) Number of outgoing handover attempts to the upper layer and a different frequency band (GSM 1800? GSM 900) Number of successful outgoing handovers to the upper layer and a different frequency band (GSM 1800? GSM 900) Number of incoming handover attempts from the lower layer and a different frequency band (GSM 1800? GSM 900) Number of incoming handovers from the lower layer and a different frequency band (GSM 1800? GSM 900) Number of successful incoming handovers from the lower layer and a different frequency band (GSM 1800? GSM 900) Number of outgoing handover attempts to the lower layer and a different frequency band (GSM 1800? GSM 900) Number of successful outgoing handovers to the lower layer and a different frequency band (GSM 1800? GSM 900) Intra-cell handover attempt times Intra-cell handover success times Intra-cell handover attempt times from the inner circle to the outer circle Explanations Source RMS Unit Cell

C10973

RMS

Cell

C10974

RMS

Cell

C10975

RMS

Cell

C10976

RMS

Cell

C10977

RMS

Cell

C10978

RMS

Cell

C10979

RMS

Cell

C10980

RMS

Cell

C10981

RMS

Cell

C10982

RMS

Cell

C10983

RMS

Cell

Page 552 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C10984 Counter description Intra-cell handover success times from the inner circle to the outer circle Intra-cell handover attempt times from the outer circle to the inner circle Intra-cell handover success times from the outer circle to the inner circle Intra-cell handover attempt times from the inner circle to the inner circle Intra-cell handover success times from the inner circle to the inner circle Intra-cell handover attempt times from the outer circle to the outer circle Intra-cell handover success times from the outer circle to the outer circle For non-concentric circle cells, it is the same as that of intra-cell handover For non-concentric circle cells, it is the same as that of intra-cell handover Explanations Source RMS Unit Cell

C10985

RMS

Cell

C10986

RMS

Cell

C10987

RMS

Cell

C10988

RMS

Cell

C10989

RMS

Cell

C10990

RMS

Cell

Note: the above counters are used to check the status of concentric circle handover.

Note: The analysis of C10901~ C10924 is from the view point of control entities. For different entities, the time delays for controlling handover are different, so here what is counted includes not only the number of execution times but also the number of successful incoming handovers. The handover success rate of TCH is not used simply here in order to determine how great the influence of handover time delay is, and also to judge how much help queuing and forced release, etc will give to improving the handover success rate. The above reasons will not be distinguished any more for the handovers of C10925~ C10980 which are judged from the view point of layers because the analysis from one view point is enough for determining the action of queuing, etc, and it is unnecessary to count from several view points. This judgment is only applicable to inter-cell handover in a BSC, and it is unable to count the external handover controlled by MSC. The counters of C10981~ C10990 are used to check the handover of concentric circles. A.2.11 RMM queue counter
Page 553 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

The RMM queue counters are listed in Table A-13. Table A-13 RMM queue counter

Counter No. C11001

Counter description

Explanations

Source

Unit

Average queue length

Queried according to the cell number Counted when quitting a queue due to queuing failure or acquiring the resources successfully The same as above Counted when acquiring the resources successfully The same as above

RMS

Cell

C11002

Total queuing time

RMS

Cell

C11003 C11004

Total number of queues Total time of successful queuing Total number of successful queues

RMS RMS

Cell Cell

C11005

RMS

Cell

Page 554 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

A.2.12

Handover synchronization mode counter The handover synchronization mode counters are listed in Table A-14. Table A-14 Handover synchronization mode counter

Counter No. C11201

Counter description Synchronized handover execution times Synchronized handover success times Pre-synchronized handover execution times Pre-synchronous handover success times Pseudo-synchronized handover execution times Pseudo-synchronized handover success times Asynchronous handover execution times Asynchronous handover success times

Source RMS

Unit Cell

C11202

RMS

Cell

C11203

RMS

Cell

C11204

RMS

Cell

C11205

RMS

Cell

C11206

RMS

Cell

C11207

RMS

Cell

C11208

RMS

Cell

A.2.13

Paging counter The paging counters are listed in Table A-15 Table A-15 Paging counter

Counter No. C11301

Counter description Number of paging messages

Explanations Number of times for sending paging messages to cells

Source L3GP

Unit Cell

A.2.14

Abis interface message counter The Abis interface message counters are listed in Table A-16.
Page 555 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Table A-16 Abis interface message counter

Counter No. C11401 C11402 C11403 C11404 C11405 C11406 C11407 C11408 C11409 C11410 C11411 C11412 C11413

Counter description DATA REQuest quantity DATA INDication quantity ERROR INDication quantity ESTablish REQuest quantity ESTablish CONFirm quantity ESTablish INDication quantity RELease REQuest quantity RELease CONFirm quantity RELease INDication quantity UNIT DATA REQuest quantity UNIT DATA INDication quantity CHANnel ACTIVation quantity CHANnel ACTIVation ACK quantity CHANnel ACTIVation Negative ACK quantity CONNection FAILure INDication quantity DEACTIVATE SACCH quantity ENCRyption CoMmanD quantity HANDOver DETection quantity MEASurement RESult quantity MODE MODIFY REQuest quantity MODE MODIFY ACKnowledge quantity MODE MODIFY Negative ACKnowledge quantity PHYsical CONTEXT REQuest quantity

Source PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS PnDS

Unit Cell Cell Cell Cell Cell Cell Cell Cell Cell Cell Cell Cell Cell

C11414

PnDS

Cell

C11415

PnDS

Cell

C11416 C11417 C11418 C11419 C11420

PnDS PnDS PnDS PnDS PnDS

Cell Cell Cell Cell Cell

C11421

PnDS

Cell

C11422

PnDS

Cell

C11423

PnDS

Cell

Page 556 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11424 Counter description PHYsical CONTEXT CONFirm quantity RF CHANnel RELease quantity MS POWER CONTROL quantity BS POWER CONTROL quantity PREPROCecc CONFIGure quantity PREPROCessed MEASurement RESult quantity RF CHANnel RELease ACKnowledge quantity SACCH INFO MODIFY quantity Source PnDS Unit Cell

C11425 C11426 C11427 C11428

PnDS PnDS PnDS PnDS

Cell Cell Cell Cell

C11429

PnDS

Cell

C11430

PnDS

Cell

C11431

PnDS

Cell

A.2.15

Radio resources availability counter The radio resources availability counters are listed in Table A-17 Table A-17 Radio resources availability counters

Counter No. C11501

Counter description

Explanations

Source

Unit

Average number of available SDCCHs Average number of unavailable SDCCHs Maximum number of busy SDCCHs Average number of busy SDCCHs Total busy time of SDCCH Total congestion time of SDCCH The total time when the cell can not get SDCCH

DBS

Cell

C11502

DBS

Cell

C11503 C11504 C11505 C11506

RMS RMS RMS RMS

Cell Cell Cell Cell

C11507

Average number of available TCH/H Average number of unavailable TCH/H Maximum number of busy TCH/H

DBS

Cell

C11508

DBS

Cell

C11509

RMS

Cell

Page 557 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11510 C11511 C11512 Counter description Explanations Source Unit

Average number of busy TCH/H Total busy time of TCH/H Total congestion time of TCH/H The total time when the cell can not get TCH/H

RMS RMS RMS

Cell Cell Cell

C11513

Average number of available TCH/F Average number of unavailable TCH/F Maximum number of busy TCH/F Average number of busy TCH/F Total busy time of TCH/F Total congestion time of TCH/F The total time when the cell can not get TCH/F

DBS

Cell

C11514

DBS

Cell

C11515 C11516 C11517 C11518

RMS RMS RMS RMS

Cell Cell Cell Cell

C11519 C11520

Total number of carriers Total number of intact carriers

DBS DBS

Cell Cell

A.2.16

Counters for generating the report forms required by the National Telecommunications Bureau The counters for generating the report forms required by the National Telecommunications Bureau are listed in Table A-18. Table a-18 the counters for generating the report forms required by the National Telecommunications Bureau

Counter No. C11601 C11602

Counter description Total number of available SDCCHs Total number of unavailable SDCCHs

Explanations The number of SDCCHs that can be assigned normally. The number of SDCCHs that cannot be assigned normally.

Source

Unit

RMS RMS

Cell Cell

Page 558 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Total call attempts of SDCCH Explanations The total number of call attempts of the system to SDCCH. The call attempts include the statuses of requesting to allocate the SDCCH, such as the normal originating call, location update, call resetup, IMSI request, IMSI separation and short message, etc. Means the total times that the system cannot assign the SDCCH channel for all the call attempts to SDCCH, i.e. the failure times of occupancy. After the system assigns the SDCCH during the calling course, the total number of call drops before the TCH is not occupied. The total time of using SDCCH The number of TCHs that can be assigned normally. The number of TCHs that cannot be assigned normally. Means all of call attempts to TCH after the SDCCH is occupied. The call attempt includes the condition that both the caller and the called parties try to set up communication, and also the status that the TCH channel is assigned to be used as SDCCH in very early allocation, but excluding various handover conditions. All overflow times of call to TCH after the SDCCH is occupied. The overflow includes the condition that the caller and callee try and fail to set up TCH after the SDCCH is occupied, and also the state that the TCH channel is assigned to be used as SDCCH in very early allocation, but not including the various handover conditions Source Unit

C11603

RMS

Cell

Total overflow times of SDCCH C11604

RMS

Cell

C11605

Total number call drops of SDCCH

RMS

Cell

C11606 C11607

C11608

Total busy time of SDCCH Total number of available voice channels Total number of unavailable voice channels Total number of call attempts of the voice channel (without containing the handover)

RMS RMS

Cell Cell

RMS

Cell

C11609

RMS

Cell

Total number overflow times of voice channel (without containing the handover) C11610

RMS

Cell

Page 559 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Total number call attempts of voice channel (containing the handover) C11611 Explanations Means the number of all call attempts to TCH after the SDCCH is occupied. The call attempt includes the condition that the caller and callee try to set up communication, and also the state that the TCH channel is assigned to be used as SDCCH in very early allocation, including the various handover and direct retry conditions. Means all overflow times of call to TCH after the SDCCH is occupied. The overflow contains the condition that the caller and callee try and fail to set up TCH after the SDCCH is occupied, also the state that the TCH channel is assigned to be used as SDCCH in very early allocation, including the various handover and direct retry conditions Indicates the successful occupancy times to the voice channel of radio interface. Source Unit

RMS

Cell

Total number of overflow times of voice channel (containing handover) C11612

RMS

Cell

C11613

C11614

C11615

Total number of occupancy times of voice channel (without containing handover) Total number of occupancy times of voice channel (containing handover) Total number of call drop times of voice channel

RMS

Cell

RMS Indicates the call loss caused by radio reasons after the voice channel is successfully assigned to users. Includes the call drops in and after handover The total sum of time that the voice channel is used. Means the total number of handover requests of the system between cells of the same BSC and those of different BSCs. Includes the number of incoming handover times to cells Means the total number of successful handover times of the system between cells of the same BSC and those of different BSCs. Includes the number of incoming handover times to cells The number of handover attempts between the systems of GSM 900M and GSM 1800

Cell

RMS

Cell

C11616

C11617

Total busy time of voice channel Total number requests for handover (number of incoming handover times)

RMS

Cell

RMS

Cell

C11618

Total number of times for successful handover (number of successful times for incoming handover) Total number of call attempts for dual frequency handover

RMS

Cell

C11619

RMS

Cell

Page 560 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description Number of success times for dual frequency handover Number messages Number of call drop C11622 times due to radio link failure Number of call drop C11623 times due to LAPD link failure Number of call drop C11624 times due to handover failure C11625 Number of random RMS Cell RMS Cell RMS Cell RMS Cell of paging Explanations The times of successful handover between the systems of GSM 900M and GSM 1800 Source Unit

C11620

RMS

Cell

C11621

access call attempts Number of successful times for random access Maximum number of

C11626

RMS

Cell

C11627

busy SDCCHs Average number of busy SDCCHs Total congestion time of SDCCH Maximum busy TCH/F Average number of busy TCH/F Total congestion time of TCH/F number of

RMS

Cell

C11628

RMS

Cell

C11629

RMS

Cell

C11630

RMS

Cell

C11631 C11632

RMS RMS

Cell Cell

C11633

Total number of intact carriers

RMS

Cell

C11634

Number of successful access times for emergent calls

RMS

Cell

C11635

Number of successful access times for call resetup

RMS

Cell

C11636

Number of successful MOC access times

RMS

Cell

C11637

Number of successful MTC access times

RMS

Cell

Page 561 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11638 Counter description Explanations Source Unit

Number of successful LOC access times

RMS

Cell

C11639

Number of success times for other access requests

RMS

Cell

C11640

Number of success times for SDCCH allocation (without handover) containing

RMS

Cell

C11641

Number of failure times for SDCCH allocation (without handover) containing

RMS

Cell

C11642

Number of success times for SDCCH allocation (containing handover)

RMS

Cell

C11643

Number of failure times for SDCCH allocation (containing handover)

RMS

Cell

C11644

Number of success times for SDCCH assignment

RMS

Cell

C11645

Number of failure times for SDCCH assignment

RMS

Cell

C11646

Number of success times for SDCCH handover

RMS

Cell

C11647

SDCCH

returned

RMS

Cell

handover failure times C11648 SDCCH non-returned RMS Cell

handover failure times C11649 Number of DTAP RMS Cell

messages used for pointto-point short messages in SDCCH uplink C11650 Number of DTAP RMS Cell

messages used for pointto-point short messages in SDCCH downlink C11651 Number of DTAP RMS Cell

messages used for pointto-point short messages in FACCH/F uplink

Page 562 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11652 Counter description Explanations Source Unit

Number

of

DTAP

RMS

Cell

messages used for pointto-point short messages in FACCH/F downlink C11653 Number of success times for TCH/F allocation including (without handover) C11654 Number of failure times for TCH/F allocation including (without handover) C11655 Number of success times for TCH/F allocation (including handover) C11656 Number of failure times for TCH/F allocation (including handover) C11657 Number of success times for TCH/F assignment C11658 Number of failure times for TCH/F assignment C11659 Number of success times for TCH/F handover C11660 Number of failure times for TCH/F returned handover C11661 Number of failure times for TCH/F non-returned handover C11662 Number of times for queuing assignment C11663 Number of times for execution of assignments due to queuing C11664 Total time length of successful queuing C11665 Number of successful times queuing Page 563 of 591 for assignment RMS Cell assignment RMS Cell RMS Cell attempt of RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell RMS Cell

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11666 Counter description Explanations Source Unit

Number of times for directional retry attempt of assignment

RMS

Cell

C11667

Number of times for execution of assignments due to directional retry

RMS

Cell

C11668

Number

of

outgoing

RMS

Cell

handover times C11669 Number of successful outgoing handover times C11670 The average number of available TCHs in interference band 1 The average number of available TCHs in interference band 2 The average number of available TCHs in interference band 3 The average number of available TCHs in interference band 4 The average number of available TCHs in interference band 5 Number of success times for intra-cell handover Number of failure times for intra-cell handover The Number of BSCcontrolled Inter-cell Incoming Handover Attempts (the actual value is the number of execution times for incoming handover) The Number of Successful BSCcontrolled inter-cell Incoming Handovers RMS Cell

C11671

C11672

C11673

C11674

C11675

C11676

C11677

C11678

Page 564 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C11679 Counter description Explanations Source Unit

The Number of BSCcontrolled Inter-cell Outgoing Handover Attempts (the actual value is the number of execution times for outgoing handover) The Number of Successful BSCcontrolled inter-cell Outgoing Handovers Number of carriers

C11680

C11681

A.3
A.3.1

SMM performance measurement counter definition


BSSMAP message counter

The BSSMAP message counters are listed in Table A-19. Table A-19 BSSMAP message counter

Counter No. C20001 C20002 C20003 C20004 C20005 C20006 C20007 C20008 C20009 C20010 C20011

Counter description Number of ASSIGNMENT REQUEST messages Number of ASSIGNMENT COMPLETE messages Number of ASSIGNMENT FAILURE messages Number of HANDOVER REQUEST messages Number of HANDOVER REQUIRED messages Number of HANDOVER COMMAND messages Number of HANDOVER REQUEST ACK messages Number of HANDOVER COMPLETE messages Number of HANDOVER FAILURE messages Number of HANDOVER PERFORMED messages Number of HANDOVER REQUIRED REJECT

Source AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS

Unit BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC

Page 565 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description messages C20012 C20013 C20014 C20015 C20016 C20017 C20018 C20019 C20020 C20021 C20022 C20023 C20024 Number of HANDOVER DETECT messages Number of CLEAR COMMAND messages Number of CLEAR COMPLETE messages Number of CLEAR REQUEST messages Number of SAPI N REJECT messages Number of uplink CONFUSION messages Number of downlink CONFUSION messages Number of SUSPEND messages Number of RESUME messages Number of MSC INVOKE TRACE messages Number of BSS INVOKE TRACE messages Number of CHANGE CIRCUIT messages Number of CHANGE CIRCUIT ACKNOWLEDGE messages Number of CIPHER MODE COMMAND messages Number of CIPHER MODE COMPLETE messages Number of CIPHER MODE REJECT messages Number of CLASSMARK UPDATE messages Number of QUEUING INDICATION messages Number of COMPLETE LAYER 3 INFORMATION messages Number of CLASSMARK REQUEST messages Number of HANDOVER CANDIDATE ENQUIRE messages Number of HANDOVER CANDIDATE RESPONSE messages Number of uplink RESET messages Number of downlink RESET messages Number of uplink RESET ACKNOWLEDGE messages Number of downlink RESET ACKNOWLEDGE AIS AIS AIS AIS AIS P0DS P0DS AIS AIS AIS AIS AIS AIS BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC Source Unit

C20025 C20026 C20027 C20028 C20029 C20030

AIS AIS AIS AIS AIS AIS

BSC BSC BSC BSC BSC BSC

C20031 C20032

AIS P0DS

BSC BSC

C20033

L3GP

BSC

C20034 C20035 C20036 C20037

L3GP P0DS L3GP P0DS

BSC BSC BSC BSC

Page 566 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description messages C20038 C20039 C20040 C20041 C20042 C20043 C20044 C20045 C20046 Number of uplink OVERLOAD messages Number of downlink OVERLOAD messages Number of uplink RESET CIRCUIT messages Number of downlink RESET CIRCUIT messages Number of uplink RESET CIRCUIT ACK messages Number of downlink RESET CIRCUIT ACK messages Number of uplink BLOCK messages Number of downlink BLOCK messages Number of uplink BLOCKING ACKNOWLEDGE messages Number of downlink BLOCKING ACKNOWLEDGE messages Number of uplink UNBLOCK messages Number of downlink UNBLOCK messages Number of uplink UNBLOCKING ACKNOWLEDGE messages Number of downlink UNBLOCKING ACKNOWLEDGE messages Number of uplink CIRCUIT GROUP BLOCK messages Number of downlink CIRCUIT GROUP BLOCK messages Number of uplink CIRCUIT GROUP BLOCKING ACKNOWLEDGE messages Number of downlink CIRCUIT GROUP BLOCKING ACKNOWLEDGE messages Number of uplink CIRCUIT GROUP UNBLOCK messages Number of downlink CIRCUIT GROUP UNBLOCK messages Number of uplink CIRCUIT GROUP UNBLOCKING ACKNOWLEDGE messages Number of downlink CIRCUIT GROUP UNBLOCKING ACKNOWLEDGE messages L3GP P0DS L3GP P0DS L3GP P0DS L3GP P0DS L3GP BSC BSC BSC BSC BSC BSC BSC BSC BSC Source Unit

C20047

P0DS

BSC

C20048 C20049 C20050

L3GP P0DS L3GP

BSC BSC BSC

C20051

P0DS

BSC

C20052 C20053

L3GP P0DS

BSC BSC

C20054

L3GP

BSC

C20055

P0DS

BSC

C20056

L3GP

BSC

C20057

P0DS

BSC

C20058

L3GP

BSC

C20059

P0DS

BSC

Page 567 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C20060 C20061 Counter description Number of uplink UNEQUIPPED CIRCUIT messages Number of downlink UNEQUIPPED CIRCUIT messages Number of RESOURCE REQUEST messages Number of RESOURCE INDICATION messages Number of PAGING messages Number of uplink LOAD INDICATION messages Number of downlink LOAD INDICATION messages Source L3GP P0DS Unit BSC BSC

C20062 C20063 C20064 C20065 C20066

P0DS L3GP P0DS L3GP P0DS

BSC BSC BSC BSC BSC

A.3.2

A interface message counter The A interface message counters are listed in Table A-20. Table A-20 A interface message counter
Counter description Explanations Source

Counter No. C20101 C20102 C20103 C20104 C20105

Unit

Number of uplink DTAP messages Number of downlink DTAP messages Number of uplink BSSMAP messages Number of downlink BSSMAP messages Error BSSMAP messages received

DTAP messages sent to MSC DTAP messages received from MSC BSSMAP messages sent to MSC BSSMAP messages received from MSC The received BSSMAP messages are in error

P0DS P0DS P0DS P0DS P0DS

BSC BSC BSC BSC BSC

A.3.3

SCCP connection counter The SCCP connection counters are listed in Table A-21. Table A-21 SCCP connection counter

Counter

Counter description

Explanations

Source

Unit

Page 568 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 No. C20201 Number of SCCP link establishment requests (BSC) Number of times for successful SCCP link establishment (BSC) Number of SCCP link establishment failures due to timeout (BSC) Number of SCCP link establishment rejection times (BSC) Number of SCCP link establishment requests (M SC) Number of times for successful SCCP link establishment (MSC) BSC sends ConnectRequest messages to MSC The number of valid ConnectConfirm messages received by BSC from MSC T9105 of BSC overflows, and no response is received from MSC After sending ConnectRequest, BSC receives DisconnectIndication from MSC BSC receives the ConnectIndication message from MSC BSC sends the ConnectResponse message to MSC P0DS BSC

C20202

P0DS

BSC

C20203

AIS

BSC

C20204

AIS

BSC

C20205

P0DS

BSC

C20206

P0DS

BSC

A.3.4

SMM assignment counter

The SMM assignment counters are listed in Table A-22. Table A-22 SMM assignment counter

Counter No. C20301 C20302

Counter description

Explanations

Source

Unit

Number of A interface assignment attempts A interface assignment failure due to circuit blocking A interface assignment failure due to mismatching of circuit group A interface assignment failure due to no response from RMM A interface assignment failure due to other reasons

The assignment requests received from MSC Since the required circuit is blocked, an assignment failure is returned. Since the required circuit group does not match, an assignment failure is returned. No response is received until timeout after an assignment request is sent to RMM Assignment failure due to any other reasons

AIS AIS

BSC BSC

C20303

AIS

BSC

C20304

AIS

BSC

C20305

AIS

BSC

A.3.5

SMM handover counter

Page 569 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

The SMM handover counters are listed in Table A-23. Table A-23 SMM handover counter

Counter No. C20401 C20402

Counter description

Explanations

Source

Unit

Number of incoming handover attempts of A interface A interface incoming handover failure due to circuit blocking A interface incoming handover failure due to mismatching of circuit group

The handover requests received from MSC Since the required circuit is blocked, an handover failure is returned. Since the required circuit group does not match, an handover failure is returned. No response is received until timeout after an handover request is sent to RMM Handover failure due to any other reasons

AIS AIS

BSC BSC

C20403

AIS

BSC

C20404

A interface incoming handover failure due to no response from RMM

AIS

BSC

C20405

A interface incoming handover failure due to other reasons

AIS

BSC

A.3.6

SMM call drop counter

The SMM call drop counters are listed in Table A-24. Table A-24 SMM call drop counter

Counter No. Counter description C20501 Number of clearing requests from RMM Number of abnormal link disconnections of SCCP Number of drop calls due to being out of contact with RMM

Explanations Received clearing requests from RMM

Source AIS

Unit BSC

C20502

Link disconnection indication messages are received from SCCP

AIS

BSC

C20503

In Serving state, T12 overflows. In Assigning state, T1 overflows. In OutgoingHO state, T8 overflows. In RadioApply state, T4 overflows.

AIS

BSC

C20504

Number of drop calls due to other reasons

In Serving state, the received HoPerformed message is incorrect. In Serving state, AssignFail or HoFail is received, which is not due to returning to

AIS

BSC

Page 570 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 the original channel. In Serving state, a ChangeCircuit message is received, but the application for circuits fails. In Assigning state, the received AssignCom message is incorrect. In Assigning state, AssignFail or HoFail is received, which is not due to returning to the original channel. AIS clears the call when receiving the EV_RELEASE_CALL message from the global module (L3GP)

Note: if SCCP link establishment is successful, then it can be regarded as entering into the conversation state. A.3.7 Land resource availability counter

The land resource availability counters are listed in Table A-25. Table A-25 Land resource availability counter

Counter No. C20601

Counter description

Explanations

Source

Unit

Average number of available trunk circuits Average number of unavailable trunk circuits Maximum number of busy trunk circuits Total busy time of trunk circuits Total congestion time of trunk circuits

Read from the database

DBS

BSC

C20602

Read from the database

DBS

BSC

C20603

The peak value of the number of seized trunk circuits Total time when each trunk circuit is seized The total time when no trunk circuit can be requested

AIS

BSC

C20604

AIS

BSC

C20605

AIS

BSC

A.4

LAPD counter
The LAPD counters are listed in Table A-26.

Page 571 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Table A-26 LAPD counter

Counter No. C30001

Counter description

Explanations

Source

Unit

Application layer data packages obtained from MP Application layer acknowledgement data packages sent BTS application layer acknowledgement data packages received BTS application layer data packages sent to MP Total number of frames sent

<10000 per minute, and <600000 per hour <10000 per minute, and <600000 per hour

LAPD

link

C30002

LAPD

Link

C30003

<10000 per minute, and <600000 per hour

LAPD

Link

C30004

<10000 per minute, and <600000 per hour <10000 per minute, and <600000 per hour <10000 per minute, and <600000 per hour <100000 per hour

LAPD

Link

C30005

LAPD

Link

C30006

Total number of frames received Total number of queue overflows Number of retransmission times Number of retransmission requests Number of link establishment times Number of link disconnection times Number of protocol errors

LAPD

Link

C30007

LAPD

Link

C30008 C30009

<100000 per hour <100000 per hour

LAPD LAPD

Link Link

C30010

<50000 per hour

LAPD

Link

C30011

<50000 per hour

LAPD

Link

C30012

<10000 per hour

LAPD

Link

A.5
A.5.1

Signaling No.7 counter


SCCP unit counter

The SCCP unit counters are listed in Table A-27. Table A-27 SCCP unit counter

Page 572 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C40001 Counter description Explanations Source Unit

Number of SIO octets received by MTP messages

Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour: 30000000 Max. per minute: 500000, per hour:

SCCP

N7TSCircuit

C40002

Number of SIO octets transmitted by MTP messages

SCCP

N7TSCircuit

C40003

Number of SIF octets received by MTP messages

SCCP

N7TSCircuit

C40004

Number of SIF octets transmitted by MTP messages

SCCP

N7TSCircuit

C40005

Number of SIO octets received by TEST messages

SCCP

N7TSCircuit

C40006

Number of SIO octets transmitted by TEST messages

SCCP

N7TSCircuit

C40007

Number of SIF octets received by TEST messages

SCCP

N7TSCircuit

C40008

Number of SIF octets transmitted by TEST messages

SCCP

N7TSCircuit

C40009

Number of SIO octets received by SCCP CLASS0 messages

SCCP

N7TSCircuit

C40010

Number of SIO octets transmitted by SCCP CLASS0 messages Number of SIF octets received by SCCP CLASS0 messages

SCCP

N7TSCircuit

C40011

SCCP

N7TSCircuit

C40012

Number of SIF octets transmitted by SCCP CLASS2 messages

SCCP

N7TSCircuit

C40013

Number of SIO octets received by SCCP CLASS2 messages

SCCP

N7TSCircuit

C40014

Number of SIO octets transmitted by SCCP CLASS2 messages Number of SIF octets received

SCCP

N7TSCircuit

C40015

SCCP

N7TSCircuit

Page 573 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter description by SCCP CLASS0 messages C40016 Number of SIF octets transmitted by SCCP CLASS2 messages Explanations 30000000 Max. per minute: 500000, per hour: 30000000 SCCP N7TSCircuit Source Unit

A.5.2

SCCP composite counter

The SCCP composite counters are listed in Table A-28. Table A-28 SCCP composite counter

Counter No. C40101

Counter description SCCP_MSGS_R X

Explanations

Source

Unit

For counting the number of Class 0 and Class2 messages i.e., number of SIOs received from a certain link, Max. per minute: 500000, per hour: 30000000 C40101 = C40009 + C40013

SCCP

N7TSCircuit

C40102

SCCP_MSGS_T X

For counting the number of Class 0 and Class2 messages i.e., number of SIOs transmitted over a certain link, Max. per minute: 500000, per hour: 30000000 C40102 = C40010 + C40014

SCCP

N7TSCircuit

A.6
A.6.1

Gb interface counter
NS sub-layer counter

The NS sub-layer counters are as listed in table A-29. Table A-29 NS sub-layer counter

Counter No.

Counter description

Counter variable name

Source

Unit

Page 574 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C50001 Number of bytes sent by the NS sublayer C50002 Number of bytes received by the NS sublayer C50003 Number of PDUs sent by the NS sublayer C50004 Number of PDUs received by the NS sublayer C50005 Number of PDUs discarded by the NS sublayer C50006 Number of reset messages sent by the NS sublayer to the opposite end C50007 Number of reset messages received from the opposite end C50008 Number of reset acknowledgement messages given by the NS sublayer to the opposite end C50009 Number of reset acknowledgement messages received from the opposite end C50010 Number of blocking messages sent by the NS sublayer to the opposite end. C50011 Number of blocking messages received from the opposite end C50012 Number of blocking acknowledgement messages given by the NS sublayer to the opposite end. Number of blocking acknowledgement C50013 messages received from the opposite end C50014 Number of unblocking messages sent by the NS sublayer to the opposite end. Number of unblocking messages dwSendUnblockPDUs FRP NSVC dwRecvBlockAckPDUs FRP NSVC dwSendBlockAckPDUs FRP NSVC dwRecvBlockPDUs FRP NSVC dwSendBlockPDUs FRP NSVC dwRecvResetAckPDUs FRP NSVC dwSendResetAckPDUs FRP NSVC dwRecvResetPDUs FRP NSVC dwSendResetPDUs FRP NSVC dwDiscDataPDUs FRP NSVC dwRecvDataPDUs FRP NSVC dwSendDataPDUs FRP NSVC dwRecvBytes FRP NSVC dwSendBytes FRP NSVC Counter description Counter variable name Source Unit

C50015

received from the opposite end Number of unblocking

dwRecvUnblockPDUs

FRP

NSVC

C50016

acknowledgement messages given by the NS sublayer to the opposite end. Number of unblocking

dwSendUnblockAckPD Us

FRP

NSVC

C50017

acknowledgement messages received from the opposite end

dwRecvUnblockAckPD Us

FRP

NSVC

Page 575 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. NS encounters abnormality in the C50018 course of transmission due to the number of times for transmission network failure NS encounters abnormality in the C50019 course of transmission due to the number of times for O&M interference NS encounters abnormality in the C50020 course of transmission due to the number of times for equipment failure NS encounters abnormality in the C50021 course of transmission due to the number of times for NS-VC blocking NS encounters abnormality in the C50022 course of transmission due to the number of times for NS-VC being unknown NS encounters abnormality in the course of transmission due to the number of times for protocol error C50023 (including PDU semantic error, dwProtocolErrorCauses FRP NSVC incompatibility of PDU with protocol, protocol error, invalid essential IE, loss of essential IE) The number of times for test process C50024 being unsuccessful (after attempting for the maximum number of times specified by NS-ALIVE-RETRIES) The number of times for blocking process C50025 times being specified unsuccessful by after dwBlockFailures FRP NSVC attempting for the maximum number of NS-BLOCKRETRIES The number of times for unblocking process C50026 being unsuccessful after dwUnblockFailures FRP NSVC attempting for the maximum number of times specified by NS-UNBLOCKRETRIES dwTestFailures FRP NSVC dwNSVCUnknownCaus es FRP NSVC dwNSVCBlockedCause s dwDevFailureCauses FRP NSVC dwOAMCauses FRP NSVC dwNetFailureCauses FRP NSVC Counter description Counter variable name Source Unit

FRP

NSVC

A.6.2

BSSGP counter

Page 576 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

The BSSGP counters are as listed in table A-30. Table A-30 BSSGP counters

Counter No. C51001

Counter description Total number of uplink UNITDATA messages processed by BSSGP Total number of downlink UNITDATA messages processed by BSSGP Number of BSC-originated packet

Counter variable name dwUlUnitDataNum

Source Unit

BRP

Cell

C51002

dwDlUnitDataNum

BRP

Cell

C51003

paging times Number of BSC-originated circuit

dwPTPPagingPSNum

BRP

Cell

C51004

paging times Number of Radio status PDU messages received by BSC Number of Status messages sent by BSC Number of Status messages received by BSC Total number of flow control messages received by BSC Total number of flow control

dwPTPPagingCSNum

BRP

Cell

C51005

dwRadioStatusNum

BRP

Cell

C51006

dwSendStatusNum

BRP

Cell

C51007

dwRcvdStatusNum

BRP

Cell

C51008

dwBVCFlowCtrlNum

BRP

Cell

C51009

acknowledgement messages received by BSC

DwBVCFlowCtrlAck Num

BRP

Cell

C51010

Total number of discarded messages requested by BSSGP-layer users Number of radio status PDU messages

dwUserReqMsgNum

BRP

Cell

C51011

received by BSC due to loss of radio contact with M S Number of radio status PDU messages

dwNoMSPDNNum

BRP

Cell

C51012

received by BSC due to radio link quality being unable to sustain further communication Number of radio status PDU messages

dwLowRSLinkPDUN um

BRP

Cell

C51013

received by BSC due to Cell reslecting command Number of times that the cause value indicated by the sending status message is equipment error

dwCellReselectPDUN um

BRP

Cell

C51014

dwSendEqErrStaNum

BRP

Cell

Page 577 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Counter variable name

Counter description Number of times that the cause value indicated by the sending status

Source Unit

C51015

dwSendNetSerFaltNu m

message is transmission network service failure Number of times that the cause value indicated by the sending status message is unknown MS Number of times that the cause value indicated by the sending status message is BVCI unknown Number of times that the cause value indicated by the sending status message is Cell traffic congestion Number of times that the cause value indicated by the sending status message is O&M intervention Number of times that the cause value indicated by the sending status message is protocol error class

BRP

Cell

C51016

dwSendNoMsStaNum

BRP

Cell

C51017

dwSendNoBUCIStaN um

BRP

Cell

C51018

dwSendCellSvrBlkSta Num

BRP

Cell

C51019

dwSendOMIntStaNu m

BRP

Cell

C51020

dwSendProErrClasSta Num dwSendProcOverStaN um

BRP

Cell

C51021

Number of times that the cause value indicated by the sending status message is processor overload

BRP

Cell

C51022

Number of times that the cause value indicated by the receiving status message is equipment error

dwRecvEqErrStaNum

BRP

Cell

C51023

Number of times that the cause value indicated by the receiving status message is transmission network service failure

dwRecvNetSerFaltNu m

BRP

Cell

C51024

Number of times that the cause value indicated by the receiving status message is unknown MS

dwRecvNoMsStaNum

BRP

Cell

C51025

Number of times that the cause value indicated by the receiving status message is BVCI unknown

dwRecvNoBUCIStaN um

BRP

Cell

C51026

Number of times that the cause value indicated by the receiving status message is Cell traffic congestion

dwRecvCellSvrBlkSta Num

BRP

Cell

C51027

Number of times that the cause value indicated by the receiving status message is O&M intervention

dwRecvOMIntStaNu m

BRP

Cell

Page 578 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C51028 Counter variable name dwRecvProErrClasSta Num

Counter description Number of times that the cause value indicated by the receiving status message is protocol error class

Source Unit BRP Cell

C51029

Number of times that the cause value indicated by the receiving status message is processor overload

dwRecvProcOverSta Num

BRP

Cell

C51030

Number of suspend messages received by BSC

dwGetSuspendMsgNu m dwRetSuspendAckNu m

BRP

Cell

C51031

Number of suspend acknowledgement messages returned by SGSN

BRP

Cell

C51032

Number SGSN

of

suspend

non-

dwRetSuspendNackN um

BRP

Cell

acknowledgement messages returned by

C51033

Number of resume messages received by BSC

dwGetResumeMsgNu m dwRetResumeAckNu m dwSendFlushPDUMs gNum dwGetFlushPDUAck Num

BRP

Cell

C51034

Number of resume acknowledgement messages returned by SGSN

BRP

Cell

C51035

Number of FLUSH-LL PDU messages received by BSC from SGSN

BRP

Cell

C51036

Number BSC

of

FLUSH-LL-

BRP

Cell

acknowledgement messages sent by

C51037

Number of blocking messages sent by BSS

dwSendBVCBlkNum

BRP

Cell

C51038

Number of blocking acknowledgement messages received by BSS

dwRcvdBVCBlkAck Num dwSendBVCUnBlkN um

BRP

Cell

C51039

Number of unblocking messages sent by BSS

BRP

Cell

C51040

Number BSS

of

unblocking

dwRcvdBVCUnBlkA ckNum

BRP

Cell

acknowledgement messages received by

C51041 C51042

Number of reset messages sent by BSS Number of reset messages received by BSS

dwSendBVCRstNum dwRcvdBVCRstNum

BRP BRP

Cell Cell

C51043

Number of reset acknowledgement messages sent by BSS

dwSendBVCRstAckN um dwRcvdBVCRstAck Num

BRP

Cell

C51044

Number of reset acknowledgement messages received by BSS

BRP

Cell

A.6.3

Paging performance measurement counter

Page 579 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

NSE performance measurement counters are as listed in table A-31. Table A-31 NSE performance measurement counters

Counter No. C52001

Counter description

Counter variable name

Source Unit

Number of times that BSS receives CS Paging

dwCSPagings

GGP

NSE

C52002

Number of times that BSS receives PS Paging

dwPSPagings

GGP

NSE

C52003 C52004 C52005

Total number of sending status messages Total number of receiving status messages Number of times that the cause value indicated by the sending status message is equipment error

dwSendStatusePDUs dwRecvStatusePDUs dwSendEquFailures

GGP GGP GGP

NSE NSE NSE

C52006

Number of times that the cause value indicated by the sending status message is transmission network service failure

dwSendNetFailures

GGP

NSE

C52007

Number of times that the cause value indicated by the sending status message is unknown M S

dwSendUnkownMSe s

GGP

NSE

C52008

Number of times that the cause value indicated by the sending status message is BVCI unknown

dwSendUnkonwBVC Is

GGP

NSE

C52009

Number of times that the cause value indicated by the sending status message is Cell traffic congestion

dwSendCellCongs

GGP

NSE

C52010

Number of times that the cause value indicated by the sending status message is O&M intervention

dwSendOAMInterve ntions

GGP

NSE

C52011

Number of times that the cause value indicated by the sending status message is protocol error

dwSendProtocolError s

GGP

NSE

C52012

Number of times that the cause value indicated by the sending status message is processor overload

dwSendOverLoades

GGP

NSE

C52013

Number of times that the cause value indicated by the sending status message is network service transmission capability from 0>non-0 value

dwSendCapaModifie ds

GGP

NSE

Page 580 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C52014 Number of times that the cause value indicated by the sending status message is PDU semantic error C52015 Number of times that the cause value indicated by the sending status message is invalid essential information unit C52016 Number of times that the cause value indicated by the sending status message is missing essential information unit C52017 Number of times that the cause value indicated by the sending status message is missing condition information unit C52018 Number of times that the cause value indicated by the sending status message is unexpected condition dwSendUnexpedtedC IEs GGP NSE dwSendMissingCIEs GGP NSE dwSendMissingMIEs GGP NSE dwSendInvalidMIEs GGP NSE Counter description Counter variable name dwSendSemanErrors GGP NSE Source Unit

information unit C52019 Number of times that the cause value indicated by the sending status message is condition information unit error C52020 Number of times that the cause value indicated by the sending status message is protocol status incompatible C52021 Number of times that the cause value indicated by the receiving status message is equipment error C52022 Number of times that the cause value indicated failure C52023 Number of times that the cause value indicated by the receiving status message is unknown M S C52024 Number of times that the cause value indicated by the receiving status message is BVCI unknown C52025 Number of times that the cause value indicated by the receiving status message is Cell traffic congestion Page 581 of 591 dwRecvCellCongs GGP NSE dwRecvUnkonwBV CIs GGP NSE dwRecvUnkownMSe s GGP NSE by the receiving status message is transmission network service dwRecvNetFailures GGP NSE dwRecvEquFailures GGP NSE dwSendUncompatibl es GGP NSE dwSendCIEErrors GGP NSE

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C52026 Number of times that the cause value indicated by the receiving status message is O&M intenvention C52027 Number of times that the cause value indicated by the receiving status message is protocol error C52028 Number of times that the cause value indicated by the receiving status message is processor overload C52029 Number of times that the cause value indicated by the receiving status message is BVC blocking C52030 Number of times that the cause value indicated by the receiving status message is PDU semantic error C52031 Number of times that the cause value indicated unit C52032 Number of times that the cause value indicated unit C52033 Number of times that the cause value indicated message by is the receiving missing status condition dwRecvMissingCIEs GGP NSE by the receiving status message is missing essential information dwRecvMissingMIEs GGP NSE by the receiving status message is invalid essential information dwRecvInvalidMIEs GGP NSE dwRecvSemanErrors GGP NSE dwRecvBVCBlocked es GGP NSE dwRecvOverLoades GGP NSE dwRecvProtocolErro rs GGP NSE Counter description Counter variable name dwRecvOAMInterve ntions GGP NSE Source Unit

information unit C52034 Number of times that the cause value indicated message by is the receiving status condition unexpected dwRecvUnexpedted CIEs GGP NSE

information unit C52035 Number of times that the cause value indicated message is error C52036 Number of times that the cause value indicated by the receiving status message is protocol status incompatible C52037 Number of times that the cause value indicated by the receiving status message is SGSN congestion dwRecvSGSNCongs GGP NSE dwRecvUncompatibl es GGP NSE by the receiving status condition information unit dwRecvCIEErrors GGP NSE

Page 582 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. Number of times that the cause value C52038 indicated by the receiving status dwRecvCapaModifie ds message is network service transmission capability from 0>non 0 value C52039 Number of signaling BVC reset messages sent by Gb Number of signaling BVC reset ACK messages received by Gb Number of signaling BVC reset messages received by Gb Number of signaling BVC reset ACK messages sent by Gb dwSendResetPDUs dwRecvResetAckPD Us dwRecvResetPDUs dwSendResetAckPD Us GGP NSE GGP NSE Counter description Counter variable name Source Unit

C52040

GGP

NSE

C52041

GGP

NSE

C52042

GGP

NSE

A.7
A.7.1

BSS counter
Traffic statistic counter

Traffic statistic counters are as listed in table A-32. Table A-32 Traffic statistic counters

Counter No. C60001 C60002 C60003 C60004

Counter description Number of used PPCHs Total number of PRACHs Number of used PAGCHs Total number of blocks (except for DUMMY frame) Total number of downlink sending blocks Total number of downlink

Counter variable name dwPPCHUsedNum dwPRACHTotalNum dwPAGCHUsedNum dwTotalExceptDummyB lkNum dwDlSendBlockNum

Source BPR BPR BPR BPR

Unit Cell Cell Cell Cell

C60005

BPR

Cell

C60006

retrying blocks Number of times for invalid reservation of uplink blocks Number of used uplink

dwDlRetryBlockNum

BPR

Cell

C60007

dwUlInvalidReservNum dwUlPDTCHPACCHUs edNum

BPR

Cell

C60008

PDTCH/PACCHs Number of used downlink

BPR

Cell

C60009

dwDlPDTCHPACCHUs edNum

PDTCH/PACCHs

BPR

Cell

Page 583 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C60010

Counter description Number conversion times from CS1 to CS2 Number conversion times from CS2 to CS1 Block retransfer rate of RLC Real loading rate of cell Average real loading rate of cell PDCH PCCCH load rate PRACH load rate PPCH load rate PAGCH load rate PDTCH/PACCH utilization rate Uplink utilization rate Downlink utilization rate Uplink power control PDTCH/PACCH PDTCH/PACCH

Counter variable name dwCS1toCS2ChangeTi mes dwCS2toCS1ChangeTi mes dwRLCBLockRetransfer Rate dwCellRealLoadRate dwCellPDCHRealLoadR ate dwPCCCHLoadRate dwPRACHLoadRate dwPPCHLoadRate dwPAGCHLoadRate dwPDTCHPACCHUtiliz eRate dwUlPDTCHPACCHUti lizeRate dwDlPDTCHPACCHUti lizeRate dwUlPowerControl

Source

Unit

BPR

Cell

C60011

BPR

Cell

C60012 C60013 C60014 C60015 C60016 C60017 C60018 C60019

BRP BRP BRP BRP BRP BRP BRP BRP

Cell Cell Cell Cell Cell Cell Cell Cell

C60020

BRP

Cell

C60021 C60022

BRP BRP

Cell Cell

A.7.2

Resource management counter

Resource management counters are as listed in table A-33. Table A-33 Resource management counter

Counter No. C61001

Counter description Number of times that BSC forcedly retract dynamic PDCH Number of times for activation of dynamic PDCH Number of times for successful activation of dynamic PDCH Number of times activation for of

Counter variable name

Source

Unit

dwRecedeDynPDCHTimes

GSP

Cell

C61002

dwDynPDCHActTimes

GSP

Cell

C61003

dwDynPDCHActSucTimes

GSP

Cell

C61004

unsuccessful dynamic PDCH

dwDynPDCHActFailTimes

GSP

Cell

C61005

PDCH availability statistics

dwPDCHAvail

GSP

Cell

Page 584 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No. C61006 C61007

Counter description Number of PDCH failure times Number of PDCH failure

Counter variable name dwPDCHFaultTimes dwPDCHFaultRecovTimes

Source GSP GSP

Unit Cell Cell

recovery times Average number of available PDCHs Maximum number of available PDCHs M inimum number of available PDCHs Average number of occupied PDCHs Maximum number of occupied PDCHs Minimum number of occupied PDCHs Number of channel blocking times Number of channel unblocking times Number of uplink data blocks

C61008

dwMeanAvailPDCH

GSP

Cell

C61009

dwMaxAvailPDCH

GSP

Cell

C61010

dwMinAvailPDCH

GSP

Cell

C61011

dwMeanOccPDCH

GSP

Cell

C61012

dwMaxOccPDCH

GSP

Cell

C61013

dwMinOccPDCH

GSP

Cell

C61014

dwPDCHBlkTimes

GSP

Cell

C61015

dwPDCHUnblkTimes

GSP

Cell

C61016

sent by the c ell over the Um interface Number of downlink data blocks

dwUmUlBlockNum

GSP

Cell

C61017

sent by the c ell over the Um interface

dwUmDlBlockNum

GSP

Cell

C61018

Number

of

packet

channel

assignment requests Number of successful packet channel assignment requests Arithmetic mean of the time

dwPCHAssReqNum

GSP

Cell

C61019

dwSuccPCHAssReqNum

GSP

Cell

C61020

interval between two continuous packet channel access requests originated by MS

dwMeanPSInterArrivalTime

GSP

Cell

C61021

Number of uplink assignment processes attempted by the cell Number of successful uplink

dwTotalAttUpAssProcs

GSP

Cell

C61022

assignment processes attempted by the cell

dwSusTotalAttUpAssProcs

GSP

Cell

C61023

Number of downlink assignment processes attempted by the cell

dwTotalAttDnAssProcs

GSP

Cell

Page 585 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No.

Counter description Number of successful downlink

Counter variable name

Source

Unit

C61024

assignment processes attempted by the cell Number of uplink assignment

dwSusTotalAttDnAssProcs

GSP

Cell

C61025

processes attempted by the cell due to one phase access Number of successful uplink

dwAttAssProcsOnePhaseAc cess

GSP

Cell

C61026

assignment processes attempted by the cell due to one phase access Number of uplink assignment

dwSusAttAssProcsOnePhase Access

GSP

Cell

C61027

processes attempted by the cell due to single block packet access Number of successful uplink

dwAttImmAssProcsSBPacke tAccess

GSP

Cell

C61028

assignment processes attempted by the cell due to single block packet access Number of uplink assignment

dwSusAttAssProcsSBPacket Access

GSP

Cell

C61029

processes attempted by the cell due to paging response Number of successful uplink

dwAttAssProcsPagResp

GSP

Cell

C61030

assignment processes attempted by the cell due to paging response Number of uplink assignment

dwSusAttAssProcsPagResp

GSP

Cell

C61031

processes attempted by the cell due to cell updating Number of successful uplink

dwAttAssProcsCellUpdate

GSP

Cell

C61032

assignment processes attempted by the cell due to cell updating Number of uplink assignment

dwSusAttAssProcsCellUpdat e

GSP

Cell

C61033

processes attempted by the cell due to mobility management Number of successful uplink

dwAssProcsMMMange

GSP

Cell

C61034

assignment processes attempted by the cell due to mobility management Number of uplink assignment

dwSusAssProcsMMMange

GSP

Cell

C61035

processes attempted by the cell due to two phase access

dwAttAssTwoPhaseAccess

GSP

Cell

Page 586 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Counter No.

Counter description Number of successful uplink

Counter variable name

Source

Unit

C61036

assignment processes attempted by the cell due to two phase access Number of uplink assignment

dwSusAttAssTwoPhaseAcce ss

GSP

Cell

C61037

processes attempted by the cell due to short access Number of successful uplink

dwAttAssShortAccess

GSP

Cell

C61038

assignment processes attempted by the cell due to short access

dwSusAttAssShortAccess

GSP

Cell

C61039

Number of successfully seized PDTCHs Number of messages waiting for sending over PCH-AGCH Number of paging messages deleted for the PCH queue Number of packet paging the

dwSuccPDTCHSeizureNum

GSP

Cell

C61040

dwPCHAGCHWaitMsgNum dwPCHDelPagMsgNum

GSP

Cell

C61041

GSP

Cell

C61042

messages

deleted

from

dwPPCHDelPagPSMsgNum

GSP

Cell

PPCH queue C61043 Number of paging messages that fail to be sent by the cell Average number of messages C61044 waiting for sending over PCHAGCH Average number of messages C61045 waiting for sending over the PPCH-PAGCH subchannel of PCCCH dwPPCHPAGCHWaitMsgM eanNum GSP Cell dwPagMsgSentFailNum GSP Cell

dwPCHAGCHWaitMsgMea nNum

GSP

Cell

A.8
A.8.1

Other counters
RMM load counter

The RMM load counters are listed in Table A-34. Table A-34 RMM load counter
Counter No. C90101 Counter description Average load of the processor Source OSS Unit % Page 587 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 C90102 C90103 C90104 Peak value of processor load Average value of seized memory resources Peak value of seized memory resources OSS OSS OSS % % %

A.8.2

Service load counter

The service load counters are listed in Table A-35. Table A-35 Service load counter
Counter No. C90201 Counter description BHCA Explanations The BHCA of SMM means that, when any instance is created for AIS: the EstablishIndcation message from RMM is received (during initial access). The BHCA of RMM means that, when any instance is created for RMS: the ChannelRequired message of BTS is received. the HandoverRequest message from SMM is received. the handover request message from the local module or other RMMs is received. Source AIS Or RMS Unit Numb er of calls/h our

A.8.3

SMM Load counter

The SMM Load counters are listed in Table A-36. Table A-36 SMM load counter
Counter No. C90401 C90402 C90403 C90404 Counter description Average load of the processor Peak value of processor load Average value of seized memory resources Peak value of seized memory resources Source OSS OSS OSS OSS Unit % % % %

Page 588 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2

Appendix B Acronyms
Acronyms Abis AIPP AIU AUC BAF BCCH BIE BIPP BIU BOSN BRP BSIA BSC BSS BSSAP BSSGP BTS BVC CBCH CCCH CDF CLF CMIP CMIS CRF CS DRT DSP EDRT EFD EGSM ESU FN FR FRP FTAM FU FUC GGSN A-bis Interface A Interface Peripheral Processor A Interface Unit Access Unit Controller BSS Adapter Function Broadcast Channel Base station Interface Equipment aBis Interface Peripheral Processor aBis Interface Unit Bit Oriented Switching Network BSSGP RLC/MAC Protocol Base Station Interface Adapter Base Station Controller Base station Sub System Base station Sub System Application Part Base station Sub System GPRS Protocol Base Transceiver Station BSSGP Virtual Connect Cell Broadcast Channel Common Control Channel Commands Dispatching Function Commands Logging Function Common Management Information Protocol Common Management Information Service Commands Resolution Function Circuit Switched Dual-Rate Transcoder Digital Signal Processor Enhanced DRT Event Forwarding Discriminator Extend GSM Executable Software Unit Frame Number Frame Relay FR Protocol File Transfer Access Maintenance Frame Unit Frame Unit Controller Gateway GPRS Support Node Page 589 of 591 Full name

Operation Manual of ZXG10-BSC (V2)-Vol 2 Acronyms GIPP GIU GPRS GSM GSN HMS HSN LAF LAPD LMF LMT MAC MAF MAIO MIB MIT MF MKF MMI MML MO MOC MOF MP MS MSC MSF MTP NAF NC NEF NMC NS NSVC OMC OMCR OOF OSF PACCH PAGCH PCU PDCH Full name Gb Interface Peripheral Processor GPRS Interface Unit General Packet Radio Service Globe System for Mobile communication GPRS Support Node ZXIP10-AS HMS Hopping Sequence Number Local Access Function Link Access Protocol of D-Channel Local Management Function Local Management Terminal Medium Access Control Management Application Functions Mobile Allocation Index Offset Management Information Base MO Instance Tree Mediation Function MMI Kernel Function Man Machine Interface Man Machine Language Managed Object Managed Object Class MO administration Function Main Processor Mobile Station Mobile Switch Center Management Support Function Message Transfer Part NMC Access Function Network Control Network Element Function Network Management Center Network Service NS Virtual Circuit Operation Maintenance Center Operation Maintenance Center Radio Operation Outputting Function Operations Systems Function Packet Associated Control Channel Paging & Access Granted Channel Packet Control Unit Packet Data Channel Page 590 of 591

Operation Manual of ZXG10-BSC (V2)-Vol 2 Acronyms PDTCH PDU PP PS PTM PTP PUC PVC RACH RMM RLC SDCCH SGSN SMB SMM SMS SSF TC TCH TCPP TIC TMN TRAU TRX UISF WAF WSF Full name Packet Data Traffic Channel Protocol Data Unit Peripheral Processor Packet Switched Point To Multipoint Point To Point Packet Unit Control Permanent Virtual Circuit Random Access Channel Radio Management Module Radio Link Control Specified Control Channel Serving GPRS Support Node Short Message Broadcast Service Management Module Short Message Service Session Services Function TransCoder Traffic Channel TransCoder unit Peripheral Processor Trunk Interface Circuit Telecommunication Management Network Transcoder and Rate Adaptor Unit Transceiver User Interface Support Function Windows Administration Function WorkStation Function

Page 591 of 591