Air Handling Units

I- Arrangements

1- Year Round Commercial AHU


Mixing Box Panel Filter Cooling Coil G4 SHF= 0.9 : 0.7 Electric Heater Supply Fan

1-Mixing plenum 2-Cooling Coil

1-Mixing plenum 2-Filter G4 3-Cooling Coil 4-Electric Heater 5-Supply Fan

1-Mixing plenum 2-Electric Heater

2- Year Round Commercial AHU Central Heating


Mixing Box Panel Filter Cooling Coil G4 SHF= 0.9 : 0.7 Heating Coil Supply Fan

1-Mixing plenum 2-Cooling Coil

1-Mixing plenum 2-Filter G4 3-Cooling Coil 4-Heating coil 5-Supply Fan

1-Mixing plenum 2-Heating coil

3- Year Round Commercial AHU in Sandy Climate


Mixing Box Panel Filter Cooling Coil G4 SHF= 0.9 : 0.7 Electric Heater Supply Fan

Sand trap louvers

1-Mixing plenum 2-Cooling Coil

1-Mixing plenum with Fresh air intake with sand trap louvers 2-Filter G4 3-Cooling Coil 4-Electric Heater 5-Supply Fan

1-Mixing plenum 2-Electric Heater

4- Year Round Commercial AHU Cinema / Theater / Musical Recording


Mixing Box Panel Filter Cooling Coil G4 SHF= 0.9 : 0.7 Electric Heater Supply Fan Sound Attenuator

1-Mixing plenum 1-Mixing plenum 2-Cooling Coil 2-Filter G4 3-Cooling Coil 4-Electric Heater 5-Supply Fan 6- Sound attenuator 1-Mixing plenum 2-Electric Heater

5- Year Round AHU in Dry Summer Climate


Heating Coil Panel Filter Eliminator Mixing Box Air Washer Precooling Coil

Supply Fan

1-Mixing plenum 2-Filter G4 1-Mixing plenum 2-Precooling Coil 3-Air Washer 3-Precooling Coil 4-Heating Coil 5-Air Washer 6-Eliminator 7-Supply Fan 1-Mixing plenum 2-Heating Coil 3-Air Washer

6- Year Round AHU Year- Round Humidity Control Pharmaceutical Clean Single Room Class C
Mixing Box Cooling Coil Empty Module SHF= 0.7 : 0.6 Panel Filter Steam Humidifier G4 Bag Filter Heating / Reheating Coil F9 Supply Fan HEPA Filter H13

Sand trap louvers

1-Mixing plenum with Fresh air intake with sand trap louvers 2-Filter G4 3-Bag Filter F9 4-Cooling Coil 1-Mixing plenum 2-Cooling Coil 3-Reheating Coil 5-Heating / Reheating Coil 6-Empty Module/ Steam Humidifier 7-Supply Fan 8- Built-in HEPA Filter H13 1-Mixing plenum 2-Heating coil 3-Steam Humidifier

7- Year Round AHU Year- Round Humidity Control Pharmaceutical Clean Room Class C with terminal HEPA Filters
Panel Filter G4 Mixing Box Cooling Coil SHF= 0.7 : 0.6 Bag Filter F9 Empty Module Steam Humidifier Heating / Reheating Coil Supply Fan

Sand trap louvers

1-Mixing plenum with Fresh air intake with sand trap louvers 2-Filter G4 3-Bag Filter F9 1-Mixing plenum 2-Cooling Coil 3-Reheating Coil 4-Cooling Coil 5-Heating / Reheating Coil 6-Empty Module/ Steam Humidifier 7-Supply Fan 1-Mixing plenum 2-Heating coil 3-Steam Humidifier

8- Year Round AHU With Return Air and Fresh Air Units Pharmaceutical Clean Room Class C with terminal HEPA Filters
Exhaust Return Fan Return Intake Panel Filter G4

Return Air Unit

Swirl Diffuser With Treminal HEPA Filter H13

Supply Air Unit


Mixing Box

Bag Filter F9

Cooling Coil Heating Coil Empty Module SHF= 0.8 : 0.7 Steam Humidifier

Supply Fan Sand trap louvers

Fresh Air Unit

Fresh Air Duct

Fresh Air Fan

Panel Filter Precooling Coil G4 Fresh Intake SHF= 0.75 : 0.65 Preheating Coil

9- Year Round AHU Year- Round Humidity Control Pharmaceutical Clean Room Class D
Cooling Coil Empty Module Panel Filter SHF= 0.7 : 0.6 Steam Humidifier G4 Heating / Reheating Coil Mixing Box Rigid Bag Filter F9

Supply Fan

Sand trap louvers

1-Mixing plenum with Fresh air intake with sand trap louvers 2-Filter G4 3-Cooling Coil 1-Mixing plenum 2-Cooling Coil 3-Reheating Coil 4-Heating / Reheating Coil 5-Empty Module/ Steam Humidifier 6-Supply Fan 7-Rigid Bag Filter F9 1-Mixing plenum 2-Heating coil 3-Steam Humidifier

10- Year Round All Fresh Outside Air AHU Year- Round Humidity Control Surgical Area in Hospitals
Sand trap louvers Cooling Coil Reheating Coil SHF= 0.5 : 0.45 Panel Filter Empty Module G4 Steam Humidifier Bag Filter Preheating Coil Fresh Intake F9 HEPA Filter H13 Supply Fan

1- Fresh air intake with sand trap louvers 2-Filter G4 3-Bag Filter F9 4-Preheating Coil 5-Cooling Coil 1-Fresh Intake 2-Cooling Coil 3-Reheating Coil 6-Empty Module/ Steam Humidifier 7-Reheating Coil 8-Supply Fan 9-HEPA Filter H13 1-Fresh Intake 2-Preheating coil 3-Steam Humidifier 4-Reheating Coil

11- Year Round All Fresh Outside Air AHU Year- Round Humidity Control Intensive Care in Hospitals
Sand trap louvers Fresh Intake Cooling Coil Reheating Coil SHF= 0.5 : 0.45 Panel Filter Empty Module G4 Steam Humidifier Preheating Coil Supply Fan Rigid Bag Filter F9

1- Fresh air intake with sand trap louvers 2-Filter G4 3-Preheating Coil 4-Cooling Coil 1-Fresh Intake 2-Cooling Coil 3-Reheating Coil 5-Empty Module/ Steam Humidifier 6-Reheating Coil 7-Supply Fan 8-Rigid Bag Filter F9 1-Fresh Intake 2-Preheating coil 3-Steam Humidifier 4-Reheating Coil

12- Storage of Raw Candy , Gum and Gelatine


Steam Reheating Coil Panel Filter G4 DX Cooling Coil Supply Fan Return Intake

Rigid Bag Filter F9

1-Return Intake 2- Filter G4 3-DX Cooling Coil 4-Reheating Steam Coil 5-Supply Fan 6-Rigid Bag Filter F9
Panel Filter G4 Return Intake After cooler Supply Fan Rigid Bag Filter F9

1-Return Intake 2- Filter G4 3-Decisscent Wheel 3-After Cooler Coil 5-Supply Fan 6-Rigid Bag Filter F9

13- All Fresh Outside Air Low Dew Point Industrial Dehumidification Applications
Decisscent Wheel Decisscent Wheel

Panel Filter G4 Fresh Intake

After cooler

After cooler Supply Fan Rigid Bag Filter F9

1-Fresh Intake 2- Filter G4 3-Decisscent Wheel ( 1 ) 4-After Cooler Coil ( 1 ) 5-Decisscent Wheel ( 2 ) 6-After Cooler Coil ( 2 ) 7-Supply Fan 8-Rigid Bag Filter F9

14- Year Round AHU Year-Round Cooling

Panel Filter Eliminator Air Washer ( Winter ) Chilled Water Spray ( Summer )

Supply Fan

Mixing Box With Modulating Dampers ( winter )

1-Mixing plenum 1-Mixing plenum 2-Chilled Water Spray 2-Filter G4 3-Air Washer / Chilled Water Spray 4-Eliminator 5-Supply Fan 1-Mixing plenum 2-Air Washer

II- Modules Specifications

Specifications

Main

Additional

Sub-additional

Psychrometry

Production

Electrical

Instrumentation

Control

Civil

Architecture

Chemical

Enviromental

Heat Transfer

Fluid Mech.

Combustion

Power

Mechanical

Mechanical

Sound

Electrical

Electrical

Computer

Computer

Main Specifications
Psychrometric Calculations
Supply Air Rate m3/ hr Outside Air Rate in m3 / hr Cooling Capacity in tons-ref ( or kW ) Heating Capacity in kW Steam Humidifier Capacity in kg / hr Washer Capacity make-up water in lit / min

Cooling Coils
Chilled Water Cooling Coil
1. Air Rate 2. Cooling Capacity 3. SHF 4. Air Inlet Condition 5. Chilled Water Inlet Temperature 6. Chilled Water Temperature Rise

DX Cooling Coil
1. Air Rate 2. Cooling Capacity 3. SHF 4. Minimum Evaporating Temperature

Heating Coils
Hot Water Coil
1. Air Rate 2. Heating Capacity 3. Air Inlet Condition 4. Hot Water Inlet Temperature 5. Hot Water Temperature Drop

Heat Pump Electric Heater


1. Air Rate 2. Heating Capacity 3. Air Inlet Condition 4. Maximum Surface Temperature 1. Air Rate 2. Heating Capacity 3. Air Inlet Condition 4. Maximum Condensing Temperature

Steam Coil
1. Air Rate 2. Heating Capacity 3. Air Inlet Condition 4. Available Steam Pressure

Steam Humidifier
1. Air Rate 2. Heating Capacity 3. Air Inlet Condition 4. Maximum Steam Pressure or Temperature

Air Washer
1. Air Rate 2. Water Consumption 3. Air Inlet Condition 4. Operating Wet bulb 5. Wetting Ratio 6. Humidifying Efficiency

Filters
Coarse Dust Filter ( G ) < 7 m > 0.7 m
Air Rate is recommended Type G1 G2 G3 G4 Rated P Pa 30 50 75 150 Substitution P Pa 150 180 250 250 Rated Efficiency 60 -65 % 65 75 % 75 90 % 90 95 %

Filters
Fine Dust Filter ( F ) < 0.7 m > 0.5 m
Air Rate is recommended Type F5 F6 F7 F8 F9 Rated P Pa 85 100 120 150 250 Substitution P Pa 350 350 350 450 450 Rated Efficiency 50 60 % 60 80 % 80 90 % 90 95 % 95 98 %

Filters
High Efficiency Filter ( HEPA ) ( H < 0.5 m)
Air Rate is recommended Type H10 H11 H12 H13 H14 Rated P Pa 270 300 320 350 350 Substitution P Pa 600 600 600 600 600 Rated Efficiency < 85 % < 95 % < 99.5 % < 99.95 % < 99.995 %

Filters
Ultra Efficiency Filter ( ULPA ) ( U ) < 0.3 m
Air Rate is recommended Type U15 Rated P Pa 400 Substitution P Pa 600 Rated Efficiency 99.9995 %

Filters
Special Filters
Air Rate is recommended 1. Sand Trap Louvers 2. Deodorization ( activated Carbon Panel ) 3. Gaseous Filter 4. Viscous Filter 5. Electro-static Filter 6. Air Washer 7. Ultraviolent Ray Lamps

Filters
P = 10x ( 0.5/d )2.2

Clean Room Classes


Metric Class M x.y M1.5 M2.5 M3.5 M4.5 M5.5 M6.5 Maximum Number of Particles 0.5 m per ft3 1 10 100 1,000 10,000 100,000

Old Class

A++ A+ A B C D

1 10 100 1,000 10,000 100,000

Blower
1. Air Rate 2. External Static Pressure Drop ( Static Pressure Drop of Modules Devices not included ) 3. Minimum Efficiency