TROFFER

COMMERCIAL GRADE T8 TROFFER


FEATURES rOptimized for T8 lamps rEquipped with energy-saving ballasts rSuperior lens brightness uniformity rReinforced flat steel door or regressed aluminum door available rPositive spring-loaded steel latches and safety lock T-hinges r90% reflective white enamel finish for superior performance rMicro ballast cover reduces ballast shadow and has tool-less access rFeatures full-length, die-formed stiffeners and unibody endplate rAmple knockouts provided for continuous row wiring DIMENSIONS 1' x 4', 2' x 2', 2' x 4'

GC8 SERIES

Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details.

COMPLIANCES: UL/cUL Listed - Damp Location, NOM Certified, IC Rated, City of Chicago Approved

ORDERING INFORMATION
SAMPLE NUMBER: 2GC8-332A-UNV-EB81-U

Rating
[Blank]=Standard ATW-SW4=Chicago Rated

Width
2=2' Width [Blank]=1' Width

Trim Type
F=Aluminum Flange Trim 9 G=Concealed-T/Slot Grid 10 G=Grid/Lay-in (Standard)

Series
C8=Commercial T8 Troffer

Type
IC=IC Rated

Doorframes
[Blank]=Flat White Steel Door (Standard) FA=Flush White Extruded Aluminum c/w Spring Latch FAB=Flush Black Extruded Aluminum FAN=Flush Natural Anodized Extruded Aluminum RA=Regressed White Extruded Aluminum (3/8") RAB=Regressed Black Extruded Aluminum (3/8") RAN=Regressed Natural Anodized Extruded Aluminum (3/8")

Number of Lamps (Not Included)


2=2 Lamps 3=3 Lamps 2 4=4 Lamps 3

Wattage (Length)
17=17W T8 (24") 28T8=28W T8 (48") 32=32W T8 (48") BX40=40W Biax (24") U15/8=31W T8 (24") U6T8=32W T8 (24")

Shielding
A=#12 Pattern Acrylic A125=#12 Pattern Acrylic (.125" Thickness) A19/156=#19 Pattern Acrylic (.156" Thickness) DA=Dropped Dish Matte White Acrylic IMA48=Injection Molded Acrylic (.150" Thickness) PB1S=1/2" x 1/2" x 1/2" Silver Parabolic Louver (Styrene)

Option - Aluminum Flange Trim 1


[Blank]=SW (Single White) EN=End of Row Natural EW=End of Row White RN=In Row Natural RW=In Row White SN=Single Natural SW=Single White

Voltage 4
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 5

Options
EL=Emergency Battery Installed (Must Specify Battery Pack, See Options) Flex=Flex Installed (Reference Flex Ordering Information) GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed (Refer to Lamp Ordering Options)

Ballast Type
Biax Ballasts EB5_=T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20%. 6 ER5_=T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10%. TEB5_=T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10%. 6 T8 Ballasts EB8_=T8 Electronic Start. Total Harmonic Distortion < 10%. EB8_/PLUS=T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15 ER8_=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Performance T8 Ballasts HB8_=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 - .88 HB8_H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 - 1.20 HB8_L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 - .82 HB8_N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HR8_=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 - .88 HR8_DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8_H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 - 1.20 HR8_L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 - .79

Number of Ballasts
1=1 Ballast 2=2 Ballasts

Options 7
FR=Fire Rated Label PAF=Painted After Fabrication

Packaging
PAL=Job Pack, out of carton PALC=Job Pack, in carton U=Unit Pack

Accessories (Order Separately)


EQ-CLIP-U=T-BAR Safety Earthquake Clips 8 FCS-14W-U=1' x 4' Field Installed Flange Kit FCTKA-22W-U=2' x 2' Field Installed Flange Kit FCTKA-24W-U=2' x 4' Field Installed Flange Kit

NOTES: 1. Specify row configuration, type in catalog number when ordering complete fixtures. 2. Standard off-center ballast on 3-lamp fixtures. 3. Not available for 1'x4'. 4. Products also available in non-US voltage and frequencies for international markets. 5. Not available when specifying emergencies, voltage must be specified. 6. Not available in UNV voltage. Must specify voltage. 7. See Options or Accessories. 8. Recommended for all 9/16" ceiling systems. Four per fixture. 9. Specify row configuration, type in catalog number when ordering complete fixtures. 10. Louver is recessed by 5/16" in Concealed T or Slot Grid T.

1' x 4' 3-3/4" [95mm]

2' x 2', 2' x 4' 3-1/4" [83mm]

11-3/4" [298mm]

23-3/4" [603mm]

METALUX
Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information.

7-65

Product Selection Guide | Sixth Edition | www.cooperlighting.com