Vous êtes sur la page 1sur 4

KRF

BACKFLUSH FILTER DN 32 DN 400 (ANSI 1 1/2 20) PN 16 PN 40


Applications
The KRF backflush filter is a versatile self-cleaning, maintenance-free filter for liquid media.

Krone Filter GmbH Herbert-Ludwig-Str. 12-14 28832 Achim Tel: +49 (0)4202 97 69 23 Fax: +49 (0)4202 97 69 27

info@krone-filter.com www.krone-filter.com

Brief description and operation


The electronic control monitors the differential pressure applied to the strainer by means of a differential pressure switch. If the preset differential pressure of 0.2 - 2 bar (depending on the design) is attained, the cleaning function is triggered. In addition the cleaning function can be triggered by a timer or manually at the touch of a button, depending on the operating conditions. The contaminated medium flows through the flange marked inlet into the filter. The contaminated medium flows through the filter insert from the inside to the outside and escapes from the flange marked outlet as cleaned medium. The reversible flow nozzle lowers the interior of the strainer insert and simultaneously the contaminant outlet valve is opened so that a pressure gradient occurs relative to the atmosphere. This initiates strainer cleaning. The filter is designed in such a manner that the drop in pressure for optimized cleaning can be kept extremely low. Filtration is not interrupted during the backflush process in a system. After the set flushing period elapses the contaminant outlet valve closes automatically.

Fully automatic backflush filter DN 32-200

Installation
The filter is installed in pipes by means of flanges. Ensure that the standard version of the filter is installed vertically and a mechanically tension-free manner without additional loads. The medium must flow in the direction specified on the housing. Incorrect installation can cause separator malfunctions. The contaminant outlet pipe must be laid with no pressure, without cross section reduction, without an ascending gradient, and, if possible with a descending gradient.

Backflush filter with double insert

01
09/2008 by Krone Filter GmbH, subject to change

Technical data
Standard version Filter insert Filter catch Venting device Drain unit Connections Materials: Housing Seals Perforated plate/mesh Cleaning nozzle Drain valve Electric gear motor Control GGG-40 NBR 1.4301/1.4404 GGG 40/oG-CuSN 10/12 3 x 400 V / 50 Hz protection class IP 65 not attached With transformer 500 V / 400 V / 230 V 50 Hz / 60 Hz, protection class IP 65, programmable Rg 5, A 4 Electro-pneumatic (230 V - 6 bar) / (24 V - 6 bar) 20 3000 m Cover with bolts and nuts Screw Screw Flange in accordance with DIN 2632/ Form C Ball valve Ball valve ANSI or in accordance with customer specifications e.g. ANSI 1.4571, H II steel, CrNi, 1.0425 PTFE / FPM, other As specified by customer St, Ms, A 2, A 4 As specified by customer Attached on the filter as specified by the customer Special version or optional extras equipment

Contaminant outlet valve

Protection class IP65


Surface treatment Interior: Steel housing GGG-40 Surface treatment Exterior: Housing, GGG-40, Steel housing steel Stainless steel housing Synthetic resin paint RAL 5010 blue Pickled and passivated without

Electrical Ex protection version, ATEX

epoxy-resin paint, hard rubber, ECTFE, glass bead blasted

Glass bead blasted

We manufacture and deliver additional design and material variants on customer request.

We request your enquiry.

02
09/2008 by Krone Filter GmbH, subject to change

Technical data and dimensions 1


Krone backwash filter with single insert

Design pressure Test pressure Design temperature

16 bar 32 bar 180 C


Oil/ emulsion throughput Weight Capacity at kg liters 60 m3/h 39 54 97 205 2.1 5.5 19 45 5 10 25 50

DN 32 40/50 65 80 100 125 150 200 250-800

Filtersurface cm2 530 1.310 3.100 6.280

a 108 113 130 195

b 73

*c 43

e 75 75

f 14 14 14 18

g 50 90 100

h 740 810 938

k 190 285 350

l 14 13 12 20

approx. m 378 410 550 560

p 126 176 270 346

q 1/2" 1/2" 1/2" 3/4"

u 84 115 190

z 660 750 900

Viscosity Water at 200 m3/h 5 15 35 90

120 49/61

160 77/90 123.5 250 *90 100 125 *169 200 150

140 1.125 650

250 1.180

10.390

236

280

175

23

200 1.300 760

20

650

400 1"

270 1.600

250

80

85

130

14.750

276

350

225

23

200 1.421 820

20

740

516

350 1.680

495

154

120

350

Larger units on request

03
09/2008 by Krone Filter GmbH, subject to change

Technical data and dimensions 2


Krone reversible filter with double sieve

Perm. operating pressure Test pressure Germ. Lloyd Test pressure PED 97/23 EG Permissible operating pressure

16 bar 24 bar 23 bar 120 C

DN 125 200 250 300 350

Filtersurface cm2 11.050 18.050 28.100 38.500 53.500

a 169 202 240 282 305

b 320 365 430 500 550

e 335 335

f 12 x 18 12 x 18

g 850 992

h 1.230 1.490

k 770 820 950

approx. approx. p m n 350 410 437 490 515 240 270 375 410 470 406 457 559 650 750

u 400

z 1.500 1.755 2.000 2.250 2.400

kg 240 320 400 580 920

Oil/ emulsion Viscosity throughput Water Liters at 60 at 200 m3/h m3/h 7o 110 175 290 390 90 145 225 310 430 200 395
KF-PCIII-08-2008-PP

3/4"

1/4

1"

450 500

445 12 x 22 1.188 1.645 515

600 890 1.200

16 x 26 1.230 1.820 1.070

1" 1"

1/2" 1/2"

11/2" 11/2"

580 620

550 20 x 22 1.462 1.920 1.170

04
09/2008 by Krone Filter GmbH, subject to change

Vous aimerez peut-être aussi