PA R T I T I O N S
Acoustic Best Practice
Single Layer
A
Cut Cormet C Stud to stop short of Cormet U Track as specified to allow for deflection Allowance for deflection between Cormet U Track and Cormet Flat Strap FS90/W
Cormet U Track Deep Flange Cormet C Stud Cormet Flat Strap FS90/W
24
25mm 2x15mm Firecheck* Notes: * Firecheck can be substituted by Megadeco, Toughcheck or MR Firecheck
Junction Details
Corner Details
B
Lafarge Wallboard as specified
Base Details
Studs, Wallboards and insulation as specified Cormet U Track as specified Lafarge Intumescent Acoustic Sealant Floating screed on resilient layer Timber sole plate same depth as screed
Skirting
DPC
Note: For the lightest acoustic performance, the partition should be fixed to the underside of the structrual soffit. Concrete Floor
T E C H N I C A L E N Q U I RY L I N E
t 01275 377789
f 01275 377456
w w w. l a f a r g e p l a s t e r b o a rd . c o . u k
APPENDIX E
PA R T I T I O N S
Acoustic Best Practice
Double Layers
A
Twin Frame
A
Cut Cormet C Stud to stop short of Cormet U Track as specified to allow for deflection Allowance for deflection between Cormet U Track and Cormet Flat Strap FS90/W
25
25mm 2x15mm Firecheck* Notes: * Firecheck can be substituted by Megadeco, Toughcheck or MR Firecheck
25mm 2x15mm Firecheck* Notes: * Firecheck can be substituted by Megadeco, Toughcheck or MR Firecheck
Junction Details
B
Lafarge Intumescent Acoustic Sealant
Junction Details
Studs Wallboards and insulation as specified Lafarge Intumescent Acoustic Sealant
Cormet Acoustic V Brace at maximum 1.5m vertical centres Cormet C Stud as specified
Corner Details
Lafarge Wallboard as specified Lafarge Intumescent Acoustic Sealant
Corner Details
Lafarge Intumescent Acoustic Sealant
Base Details
Studs, Wallboards and insulation as specified Cormet U Track as specified Lafarge Intumescent Acoustic Sealant Floating screed on resilient layer
Base Details
Studs, Wallboards and insulation as specified Floating screed on resilient layer Cormet U Track as specified
Skirting
DPC
DPC
Concrete Floor
Concrete Floor
T E C H N I C A L E N Q U I RY L I N E
t 01275 377789
f 01275 377456
w w w. l a f a r g e p l a s t e r b o a rd . c o . u k
APPENDIX E
PA R T I T I O N S
Application Details
Base details
Twin frame separating wall to concrete floor with screed
Lafarge wallboard, studs and insulation as specified
Lafarge Intumescent Acoustic Sealant Screed on concrete floor DPC Expansion joint in screed or fill cavity with Lafarge Intumescent Acoustic Sealant Lafarge Acoustic Tape RAFT50 pinned to end of floor deck
25
Floating screed on resilient layer Floating screed on resilient layer Timber sole plate same depth as screed Fire stop to cavity between floor slabs
Lafarge wallboard, studs and insulation as specified Lafarge Acoustic Tape RAFT50 Cormet U Track as specified Lafarge Intumescent Acoustic Sealant Screed on concrete floor DPC
Lafarge Intumescent Acoustic Sealant Floating screed on resilient layer Floating timber deck Timber acoustic battens directly below partition Timber sole plate same depth as screed
T E C H N I C A L E N Q U I RY L I N E
t 01275 377789
f 01275 377456
w w w. l a f a r g e p l a s t e r b o a rd . c o . u k
APPENDIX E PA R T I T I O N S
Application Details
Lafarge Firecheck refer to note on head packer Lafarge wallboard, studs and insulation as specified Cormet Flat strap
24
Cormet U Track to suit stud size Purlin zone 2x15mm Lafarge Firecheck wallboard
Lafarge wallboard, studs and insulation as specified Timber fillet to suit angle of roof Lafarge Firecheck refer to note on head packer FS90/W Flat Strap or MFIX Fixing Channel
Lafarge Intumescent Acoustic Sealant Lafarge wallboard, studs and insulation as specified Metal Angle MFC2330 Metal Angle Studs and wallboard cut short by required deflection FS90/W Flat Strap or MFIX Fixing Channel Insulation as specified
Lafarge Firecheck refer to note on head packer Lafarge wallboard, studs and insulation as specified Note on head packer:
Max deflection 10mm 25mm Notes: *Firecheck can be or MR Firecheck
T E C H N I C A L E N Q U I RY L I N E
t 01275 377789
f 01275 377456
w w w. l a f a r g e p l a s t e r b o a rd . c o . u k
APPENDIX E
LININGS
Application Details
Cormet Dryliner Bracket Cormet Dryliner Channel Lafarge wallboard and studs as specified Lafarge wallboard and studs as specified Cormet I Stud Lafarge Intumescent Acoustic Sealant Cormet I Stud to support partition
Dryliner Bracket
adjusted for internal corner application Vapour control layer Vapour control layer
Vapour control layer Lafarge wallboard, studs and insulation as specified Cormet I Stud
External Corners
Wall abutment
41
External cladding zone 10mm minimum cavity
Vapour control layer Lafarge Intumescent Acoustic Sealant Cormet I Stud Lafarge wallboard, studs and insulation as specified
Cormet I Stud
T E C H N I C A L E N Q U I RY L I N E
t 01275 377789
f 01275 377456
w w w. l a f a r g e p l a s t e r b o a rd . c o . u k
I.
APPENDIX E
APPENDIX E