Académique Documents
Professionnel Documents
Culture Documents
-2-
Contents
Pages
6 - 21
22 - 23
-3-
D1
D5b
L4b
D5a
L4a
Please Note:
a) All dimensions are based upon the internal vessel diameter. If external diameters are used then an allowance must be made for the
vessel wall thickness.
b) Other component combinations may be used for more complex anatomy. For advice please contact your AnacondaTM Clinical Specialist.
c) Refer to the preoperative assessment sheet for full anatomical measurement requirements.
d) Where the maximum total device length needed is between those quoted in the leg sizing tables the shorter leg should be selected.
e) Minimum leg-to-leg overlap and length of deployment site 20mm.
D1
L1
D2
L3
L2
D3
L4a
L4b
D4
D5
Right side
D6a
5b
Left side
D6b
-4-
STEP 2
STEP 3
Measure
Maximum Aortic
Vessel Internal
Diameter - D1
(mm)
Select
Bifurcated Body
Catalogue No.
Go To Page No.
16.0 - 17.5
B19
17.5 - 19.5
B21
19.5 - 21.0
B23
11
21.0 - 23.0
B25
13
23.0 - 25.0
B28
15
25.0 - 27.5
B30
17
26.5 - 29.0
B32
19
28.5 - 31.0
B34
21
B19 BODY
19.5mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
35mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
7.5mm
16 .0 m m -17. 5 m m
Flare Length
12mm
COMPATIBLE LEGS
Lengths ~
60, 80, 100,
120 & 140mm
Cat No.
Prefix
Device OD
(mm)
L10
10mm
L11
11mm
L12
12mm
Cat No.
Prefix
Lengths ~
see table
FL1215
FL1217
FL1219
FL1221
FL1223
Device OD
(mm)
12 x 15mm
12 x 17mm
12 x 19mm
12 x 21mm
12 x 23mm
Lengths
(mm)
80,110,130mm
80,110,130mm
85,110,130mm
85,110,130mm
90,110,130mm
The Flared legs may only be used as extensions and not docked directly with this body.
-6-
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
8.5 - 9.5mm
95mm
115mm
135mm
155mm
175mm
185mm - 235mm
L10X060
L10X080
L10X100
L10X120
L10X140
L10X140 + L10X080
9.0 - 10.5mm
120mm - 135mm
135mm - 155mm
155mm - 195mm
195mm - 235mm
L10X060 + L11X060
L10X080 + L11X060
L10X100 + L11X080
L10X140 + L11X080
11.0 - 12.5mm
155mm - 175mm
175mm - 195mm
195mm - 215mm
12.5 - 14.0mm
140mm - 175mm
180mm - 215mm
L10X080 + FL1215X080
L10X120 + FL1215X080
13.5 - 15.0mm
140mm - 175mm
180mm - 215mm
L10X080 + FL1217X080
L10X120 + FL1217X080
15.5 - 17.0mm
145mm - 180mm
185mm - 220mm
L10X080 + FL1219X085
L10X120 + FL1219X085
16.5 - 19.0mm
145mm - 180mm
185mm - 220mm
L10X080 + FL1221X085
L10X120 + FL1221X085
18.5 - 21.0mm
150mm - 185mm
190mm - 225mm
L10X080 + FL1223X090
L10X120 + FL1223X090
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B21 BODY
21.5mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
35mm
INTERNA L D I A ME T E R R A N GE
17. 5 m m -19. 5 m m
8.5mm
8.5mm
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L10
L11
L12
L13
Device OD
(mm)
10mm
11mm
12mm
13mm
Cat No.
Prefix
FL1215
FL1217
FL1219
FL1221
FL1223
Lengths ~
see table
Device OD
(mm)
12 x 15mm
12 x 17mm
12 x 19mm
12 x 21mm
12 x 23mm
Lengths
(mm)
80,110,130mm
80,110,130mm
85,110,130mm
85,110,130mm
90,110,130mm
The Flared legs may only be used as extensions and not docked directly with this body.
-8-
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
8.5 - 9.5mm
95mm
115mm
135mm
155mm
175mm
185mm - 235mm
L10X060
L10X080
L10X100
L10X120
L10X140
L10X140 + L10X080
9.0 - 10.5mm
95mm
115mm
135mm
155mm
175mm
185mm - 235mm
L11X060
L11X080
L11X100
L11X120
L11X140
L11X140 + L11X080
11.0 - 12.5mm
120mm - 135mm
135mm - 155mm
155mm - 195mm
195mm - 255mm
L11X060 + L13X060
L11X080 + L13X060
L11X100 + L13X080
L11X140 + L13X080
12.5 - 14.0mm
140mm - 175mm
180mm - 215mm
L10X080 + FL1215X080
L10X120 + FL1215X080
13.5 - 15.0mm
140mm - 175mm
180mm - 215mm
L10X080 + FL1217X080
L10X120 + FL1217X080
15.5 - 17.0mm
145mm - 180mm
185mm - 220mm
L10X080 + FL1219X085
L10X120 + FL1219X085
16.5 - 19.0mm
145mm - 180mm
185mm - 220mm
L10X080 + FL1221X085
L10X120 + FL1221X085
18.5 - 21.0mm
150mm - 185mm
190mm - 225mm
L10X080 + FL1223X090
L10X120 + FL1223X090
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B23 BODY
23.5mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
35mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
9.5mm
19. 5 m m -21.0 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L11
L12
L13
Device OD
(mm)
11mm
12mm
13mm
Cat No.
Prefix
Lengths ~
see table
FL1215
FL1217
FL1219
FL1221
FL1223
-10-
Device OD
(mm)
12 x 15mm
12 x 17mm
12 x 19mm
12 x 21mm
12 x 23mm
Lengths
(mm)
80,110,130mm
80,110,130mm
85,110,130mm
85,110,130mm
90,110,130mm
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
9.0 - 10.5mm
95mm
115mm
135mm
155mm
175mm
185mm - 235mm
L11X060
L11X080
L11X100
L11X120
L11X140
L11X140 + L11X080
10.0 - 11.5mm
95mm
115mm
135mm
155mm
175mm
185mm - 235mm
L12X060
L12X080
L12X100
L12X120
L12X140
L12X140 + L12X080
11.0 - 12.5mm
120mm - 135mm
135mm - 155mm
155mm - 195mm
195mm - 235mm
L11X060 + L13X060
L11X080 + L13X060
L11X100 + L13X080
L11X140 + L13X080
12.5 - 14.0mm
115mm
145mm
165mm
140mm - 175mm
180mm - 215mm
FL1215X080
FL1215X110
FL1215X130
L11X080 + FL1215X080
L11X120 + FL1215X080
13.5 - 15.0mm
115mm
145mm
165mm
140mm - 175mm
180mm - 215mm
FL1217X080
FL1217X110
FL1217X130
L11X080 + FL1217X080
L11X120 + FL1217X080
15.5 - 17.0mm
120mm
145mm
165mm
145mm - 180mm
185mm - 220mm
FL1219X085
FL1219X110
FL1219X130
L11X080 + FL1219X085
L11X120 + FL1219X085
16.5 - 19.0mm
120mm
145mm
165mm
145mm - 180mm
185mm - 220mm
FL1221X085
FL1221X110
FL1221X130
L11X080 + FL1221X085
L11X120 + FL1221X085
18.5 - 21.0mm
125mm
145mm
165mm
150mm - 185mm
190mm - 225mm
FL1223X090
FL1223X110
FL1223X130
L11X080 + FL1223X090
L11X120 + FL1223X090
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
Size availability subject to local regulatory approval.
-11-
B25 BODY
25.5mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
40mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
10.5mm
21.0 m m -2 3 .0 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L12
12mm
L13
13mm
Cat No.
Prefix
Lengths ~
see table
FL1215
FL1217
FL1219
FL1221
FL1223
-12-
Device OD
(mm)
Device OD
(mm)
12 x 15mm
12 x 17mm
12 x 19mm
12 x 21mm
12 x 23mm
Lengths
(mm)
80,110,130mm
80,110,130mm
85,110,130mm
85,110,130mm
90,110,130mm
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
100mm
L12X060
L12X080
L12X100
L12X120
L12X140
L12X140 + L12X080
100mm
11.0 - 12.5mm
120mm
140mm
160mm
180mm
190mm - 240mm
L13X060
L13X080
L13X100
L13X120
L13X140
L13X140 + L13X080
12.5 - 14.0mm
120mm
150mm
170mm
145mm - 180mm
185mm - 220mm
FL1215X080
FL1215X110
FL1215X130
L12X080 + FL1215X080
L12X120 + FL1215X080
13.5 - 15.0mm
120mm
150mm
170mm
145mm - 180mm
185mm - 220mm
FL1217X080
FL1217X110
FL1217X130
L12X080 + FL1217X080
L12X120 + FL1217X080
15.5 - 17.0mm
125mm
150mm
170mm
150mm - 185mm
190mm - 225mm
FL1219X085
FL1219X110
FL1219X130
L12X080 + FL1219X085
L12X120 + FL1219X085
16.5 - 19.0mm
125mm
150mm
170mm
150mm - 185mm
190mm - 225mm
FL1221X085
FL1221X110
FL1221X130
L12X080 + FL1221X085
L12X120 + FL1221X085
18.5 - 21.0mm
130mm
150mm
170mm
155mm - 190mm
195mm - 230mm
FL1223X090
FL1223X110
FL1223X130
L12X080 + FL1223X090
L12X120 + FL1223X090
10.0 - 11.5mm
120mm
140mm
160mm
180mm
190mm - 240mm
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B28 BODY
28.0mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
40mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
11.5mm
2 3 .0 m m -2 5 .0 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L12
L13
L15
L16
Cat No.
Prefix
Lengths ~
see table
Device OD
(mm)
12mm
13mm
15mm
16mm
Device OD
(mm)
Lengths
(mm)
FL1215
12 x 15mm
80,110,130mm
FL1217
12 x 17mm
80,110,130mm
FL1219
12 x 19mm
85,110,130mm
FL1221
12 x 21mm
85,110,130mm
FL1223
12 x 23mm
90,110,130mm
-14-
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
100mm
L12X060
L12X080
L12X100
L12X120
L12X140
L12X140 + L12X080
100mm
11.0 - 12.5mm
120mm
140mm
160mm
180mm
190mm - 240mm
L13X060
L13X080
L13X100
L13X120
L13X140
L13X140 + L13X080
12.5 - 14.0mm
100mm
120mm
140mm
160mm
180mm
190mm - 240mm
L15X060
L15X060
L15X100
L15X120
L15X140
L15X140 + L15X080
13.5 - 15.0mm
120mm
150mm
170mm
145mm - 180mm
185mm - 220mm
FL1217X080
FL1217X110
FL1217X130
L12X080 + FL1217X080
L12X120 + FL1217X080
15.5 - 17.0mm
125mm
150mm
170mm
150mm - 185mm
190mm - 225mm
FL1219X085
FL1219X110
FL1219X130
L12X080 + FL1219X085
L12X120 + FL1219X085
16.5 - 19.0mm
125mm
150mm
170mm
150mm - 185mm
190mm - 225mm
FL1221X085
FL1221X110
FL1221X130
L12X080 + FL1221X085
L12X120 + FL1221X085
18.5 - 21.0mm
130mm
150mm
170mm
155mm - 190mm
195mm - 230mm
FL1223X090
FL1223X110
FL1223X130
L12X080 + FL1223X090
L12X120 + FL1223X090
10.0 - 11.5mm
120mm
140mm
160mm
180mm
190mm - 240mm
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B30 BODY
30.5mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
40mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
12.5mm
2 5 .0 m m -27. 5 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L15
L16
L17
Cat No.
Prefix
Lengths ~
see table
Device OD
(mm)
15mm
16mm
17mm
Device OD
(mm)
Lengths
(mm)
FL1719
17 x 19mm
82,110,130mm
FL1721
17 x 21mm
85,110,130mm
FL1723
17 x 23mm
88,110,130mm
-16-
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
100mm
L15X060
L15X080
L15X100
L15X120
L15X140
L15X140 + L15X080
100mm
120mm
140mm
160mm
180mm
190mm - 240mm
L16X060
L16X080
L16X100
L16X120
L16X140
L16X140 + L16X080
100mm
120mm
140mm
160mm
180mm
190mm - 240mm
L17X060
L17X080
L17X100
L17X120
L17X140
L17X140 + L17X080
15.5 - 17.0mm
122mm
150mm
170mm
150mm - 182mm
190mm - 222mm
FL1719X082
FL1719X110
FL1719X130
L15X080 + FL1719X082
L15X120 + FL1719X082
16.5 - 19.0mm
125mm
150mm
170mm
153mm - 185mm
193mm - 225mm
FL1721X085
FL1721X110
FL1721X130
L15X080 + FL1721X085
L15X120 + FL1721X085
18.5 - 21.0mm
128mm
150mm
170mm
156mm - 188mm
196mm - 228mm
FL1723X088
FL1723X110
FL1723X130
L15X080 + FL1723X088
L15X120 + FL1723X088
12.5 - 14.0mm
13.5 - 15.0mm
14.0 - 16.0mm
120mm
140mm
160mm
180mm
190mm - 240mm
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B32 BODY
32.0mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
40mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
13.5mm
2 6 . 5 m m -2 9.0 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L16
L17
L18
Cat No.
Prefix
Lengths ~
see table
Device OD
(mm)
16mm
17mm
18mm
Device OD
(mm)
Lengths
(mm)
FL1719
17 x 19mm
82,110,130mm
FL1721
17 x 21mm
85,110,130mm
FL1723
17 x 23mm
88,110,130mm
-18-
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
100mm
L16X060
L16X080
L16X100
L16X120
L16X140
L16X140 + L16X080
100mm
120mm
140mm
160mm
180mm
190mm - 240mm
L17X060
L17X080
L17X100
L17X120
L17X140
L17X140 + L17X080
100mm
120mm
140mm
160mm
180mm
190mm - 240mm
L18X060
L18X080
L18X100
L18X120
L18X140
L18X140 + L18X080
16.5 - 19.0mm
125mm
150mm
170mm
153mm - 185mm
193mm - 225mm
FL1721X085
FL1721X110
FL1721X130
L16X080 + FL1721X085
L16X120 + FL1721X085
18.5 - 21.0mm
128mm
150mm
170mm
156mm - 188mm
196mm - 228mm
FL1723X088
FL1723X110
FL1723X130
L16X080 + FL1723X088
L16X120 + FL1723X088
13.5 - 15.0mm
14.0 - 16.0mm
15.0 - 17.0mm
120mm
140mm
160mm
180mm
190mm - 240mm
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
B34 BODY
34.0mm
NATIVE A OR T I C V E S S E L
Peak to
bifurcation
40mm
INTERNA L D I A ME T E R R A N GE
Docking zone overlap
25mm
8.5mm
14.5mm
2 8 . 5 m m - 31.0 m m
Flare Length
12mm
COMPATIBLE LEGS
Cat No.
Prefix
Lengths ~
60, 80, 100,
120 & 140mm
L17
17mm
L18
18mm
Cat No.
Prefix
Lengths ~
see table
Device OD
(mm)
Device OD
(mm)
Lengths
(mm)
FL1719
17 x 19mm
82,110,130mm
FL1721
17 x 21mm
85,110,130mm
FL1723
17 x 23mm
88,110,130mm
-20-
Measure the
Iliac Artery
Diameter
(mm)
(D5a & D5b)
Determine the
Total Device
Length Needed*
(mm)
(L4a & L4b)
Select
Appropriate
Catalogue
Number(s)
100mm
L17X060
L17X080
L17X100
L17X120
L17X140
L17X140 + L17X080
100mm
15.0 - 17.0mm
120mm
140mm
160mm
180mm
190mm - 240mm
L18X060
L18X080
L18X100
L18X120
L18X140
L18X140 + L18X080
16.5 - 19.0mm
125mm
150mm
170mm
153mm - 185mm
193mm - 225mm
FL1721X085
FL1721X110
FL1721X130
L17X080 + FL1721X085
L17X120 + FL1721X085
18.5 - 21.0mm
128mm
150mm
170mm
156mm - 188mm
196mm - 228mm
FL1723X088
FL1723X110
FL1723X130
L17X080 + FL1723X088
L17X120 + FL1723X088
14.0 - 16.0mm
120mm
140mm
160mm
180mm
190mm - 240mm
* Peak of the bifurcate body proximal ring stent to the distal iliac leg deployment site
Notes
-22-
Notes
-23-
0086
Patent No. US 6,264,662
A full range of aortic cuff components is available.