TriMod BESTA Level Switches Horizontal Line Data Sheet LTDS01E TriMod BESTA level switch types: A 01 04 and

A 01 041 Side mounted switches for high or low alarm duties


Nominal pressure Operating temperature Ambient temperature Density of liquid Operating differential Rod extensions Wetside material Flange material Switch housing material Flange dimensions Counterflange Switch element Switch rating Cable gland Enclosure Weight Approvals PN 25 max. 25 bar to 300C max. 24 bar at 330C 0 to 330C 0 to 70C min. 0.70 kg/dm3 fixed 12 mm only with type A 01 04 stainless steel (316 equiv.) stainless steel (316 equiv.) sea water resistant die cast aluminium 92 x 92 mm P.C.D. 92 mm see overleaf microswitch change-over (SPDT) with silver contacts 5A/250 VAC 5A/30 VDC PG16 IP65 approx. 1.8 kg ABS, BV, DNV, GL, LRS, PRS, RINA, MRS

49

88

71

13 39 140 2 68 226

Flange dimension
92 4 x 13
9 2

Connection diagram
11 14 12

Rod extensions for type A 01 04


Depending on the tank design the level switch type A 01 04 can be equipped with rod extension Type G1 or G2 for side mounted switches. For top mounting type G3 is used. Since rod extensions add-on weight to the float, the minimum value for the density will change according to the following tables:

Type: G1

Type: G2

A
A

64

Type: G3

A max.: 1000

A + B max.: 1000 A/B: 4 A min.: 100 B min.: 100

A + B max.: 1000 A/B: 4 A min.: 50 B min.: 50

Minimum density for the float module 04G1


Rod length A (mm) Min. density (kg/dm3) 100 0.66 200 0.66 300 0.67 400 0.69 500 0.71 600 0.74 700 0.76 800 0.79 900 0.81 1000 0.84

Minimum density for the float module 04G2


in kg/dm3 A (mm) B (mm) 100 200 300 400 500 600 700 800 900 0.69 0.67 0.68 0.70 0.72 0.74 0.77 0.79 0.82 0.68 0.67 0.69 0.70 0.73 0.75 0.77 0.80 0.70 0.68 0.69 0.71 0.73 0.75 0.77 0.71 0.69 0.70 0.71 0.73 0.75 0.72 0.70 0.71 0.72 0.74 0.74 0.75 -0.71 0.72 0.73 0.71 0.72 0.73 100 200 300 400 500 600 700 800

Minimum density for the float module 04G3


in kg/dm3 A (mm) B (mm) 50 100 200 300 400 500 600 700 800 900 950 0.71 0.69 0.68 0.69 0.71 0.73 0.75 0.77 0.80 0.82 0.83 --0.68 0.69 0.71 --0.68 0.69 --0.68 50 to 500 600 700 800

117

Options
Dual SPDT microswitches Microswitches with gold plated contacts Self checking proximity switches acc. to NAMUR Enclosure IP67, or IP68 for submersible applications 5A/380 VAC 0,3A/440 VDC (Type AE26) Flameproof switches, BASEEFA-, PTB-, SAA- and SEV-approved Pneumatic switches ON/OFF or controllers with 0.2 to 1 bar proportional output High and low temperature versions Cable gland M24 x 1,5 Cable entry with 3/4" NPT internal thread - chromated - stainless steel (316 equiv.) - epoxy painted Flange modules: - acc. to DIN PN 16 to PN 315 - acc. to ANSI cl. 150 to cl. 2500 - acc. to BS10 table E to T - acc. to JIS PN 5 to PN 63 Float modules: - top mounting - interface control - with protective bellows - min. density 0.35 kg/dm3 Versions acc. to NACE and in Hastelloy C or MONEL Switch housing:

Counterflanges
The simplest method of installing the TriMod BESTA level switches with the square flange (standard range) is to use the BESTA standard weld-on counterflanges. These are available in two different nozzle and/or stud lengths in carbon steel (C22.8) or in stainless steel 1.4401 (316 equiv.). Type 2829.1 2831.3 Specification Counterflange Counterflange Flange material C22.8 1.4401 C22.8 1.4401 Stud material 5.8 A2 5.8 A2 Temperature range: Material C22.8: Material 1.4401: -10 C to +400 C -196 C to +400 C

30

V=38

92 x 92 M 12
76.1

2 9 65

2829.1V80 Extended Counter2831.3V80 flange V = 80 mm

Test actuator
The test actuator allows a periodic, on-line manual function check of the level switch. Type 2383.2 Specification Test actuator L with intermediary Test actuator L with intermediary Material CrNi C22.8 CrNi CrNiMo Temperatur 0 to +150C
155

Test actuator L Intermediary

2383.3

0 to +150C
42

Float chambers
Wherever it is not possible or desirable to install float switches directly to the vessel, horizontal TriMod BESTA level switches can be mounted externally in a float chamber. This type of installation allows functional checks and servicing to be carried out without interrupting operation, provided that isolation and drain valves are included in the process connections. Materials: carbon steel, high and low temp. carbon steel, stainless steel. Manufacturing approvals: Swiss-SVTI and German-TV Procedure Qualification Record: SVTI 505, AD-HP 2/1, ASME Code Sec. IX.

Figure A

Certificates
Material certificates acc. to EN 10204-2.2 and EN 10204-3.1B Test record: hydraulic pressure test and functional tests Test records of material tests: x-ray, ultra sonic, charpy, hardness etc.
With reservation of technical modifications

Quality Assurance
BESTA AG is certified according to ISO 9001.

LTDS01E/07.97

Ackerstrasse 45, CH-8610 Uster/Switzerland Phone +41-1-941 30 20, Fax +41-1-941 40 15 E-Mail: info@besta.ch http://www.besta.ch
Printed in Switzerland

TriMod BESTA Level Switches Horizontal Line Data Sheet LTDS03E TriMod BESTA level switches with adjustable operating differential for pump control Types: A 01 090, A 01 091, A 01 092, A 01 093, A 01 095
Nominal pressure Operating temperature Ambient temperature Density of liquid Operating differential S Wetside material Flange material Switch housing material Flange dimensions Counter flanges Switch element Switch rating Cable gland Enclosure Weight Approvals PN 25 max. 25 bar to 300 C max. 24 bar at 330 C 0 to 330 C 0 to 70 C min. 0.8 kg/dm3 (A 01 095 min. 0.90 kg/dm3) see table below stainless steel (316 equiv.) stainless steel (316 equiv.) sea water resistant die cast aluminium 92 x 92 mm P.C.D. 92 mm see overleaf microswitch changeover (SPDT) with silver contacts 5A/250 VAC 5A/30 VDC PG16 IP65 approx. 2.0 kg ABS, BV, DNV, GL, LRS, PRS, RINA, MRS
92 4 x 13
2 9

49

88

71

Z2

Z1

X2

X1

13 39 2 140 68 L

Adjustment of switching differential


The switching differential can be set by inserting pegs in holes 1 to 9 of the adjustment block (see sketch). The resulting differentials, the position of the switching points and the overall swept arc of the float can be seen in the table below. The values are in mm and are referenced to water at 20C and density of 1.0 kg/dm3.

1 2 3 4 5 6 7 8 9

Connection diagram
11 14 12

7\ S H

6 

 ( 

6

 (

6 

 ( !

6

 ( "

6 4

6

 ( $

L P os. X1

278 m m X2 D i ff. S 48 93 133 160 188 218 83 123 150 178 208 43 83 11 0 138 168 50 77 105 135 37 65 95 55 Y1 (Z 2 ) 175 175 175 175 175 175 153 153 153 153 153 125 125 125 125 125 85 85 85 85 35 35 35 (1 0 ) Y2 (Z 1 ) X1

361 mm X2 D i ff. S 72 132 194 247 285 317 97 159 212 250 282 56 11 8 171 209 241 68 121 159 191 57 95 127 80 Y1 (Z 2 ) 238 238 238 238 238 238 206 206 206 206 206 165 165 165 165 165 105 105 105 105 37 37 37 (2 0 ) Y2 (Z 1 ) X1

461 m m X2 D i ff. S 105 191 281 354 401 442 142 232 305 352 393 83 173 246 293 334 99 172 219 260 84 131 172 107 Y1 (Z 2 ) 315 315 315 315 315 315 275 275 275 275 275 215 215 215 215 215 135 135 135 135 39 39 39 (5 0 ) Y2 (Z 1 ) X1

561 m m X2 D i ff. S 132 244 357 452 507 557 182 295 390 445 495 97 210 305 360 410 128 223 278 328 11 0 165 215 130 Y1 (Z2 ) 395 395 395 395 395 395 345 345 345 345 345 265 265 265 265 265 165 165 165 165 42 42 42 (7 5 ) Y2 (Z 1 ) X1

246 m m X2 D i ff. S 45 82 11 8 146 170 190 61 97 125 149 169 34 70 98 122 142 41 69 93 11 3 34 58 78 45 Y1 (Z 2 ) 147 147 147 147 147 147 128 128 128 128 128 11 5 11 5 11 5 11 5 11 5 74 74 74 74 35 35 35 (1 0 ) Y2 (Z 1 ) (1 0 ) 35 74 11 5 128 147 35 74 11 5 128 147 35 74 11 5 128 147 74 11 5 128 147 11 5 128 147 147

1 -4 1 -5 1 -6 1 -7 1 -8 1 -9 2 -5 2 -6 2 -7 2 -8 2 -9 3 -5 3 -6 3 -7 3 -8 3 -9 4 -6 4 -7 4 -8 4 -9 5 -7 5 -8 5 -9 6 -9

108 108 108 108 108 108 9 8 9 8 9 8 9 8 9 8 5 8 5 8 5 8 5 8 5 8 2 5 2 5 2 5 2 5


15 15 15

60  15
  

(1 0 )  1 5 7 35 157 85 157 125 157 153 157 175 157 35 122 85 122 125 122 153 122 175 122 35 85 125 153 175 85 125 153 175 125 153 175 175

85 25
 

(2 0 )  2 3 0 37 230 105 230 165 230 206 230 238 230 37 105 165 206 238

1 25 39


(5 0 )  2 9 2 39 292 135 292 215 292 275 292 315 292 39 230 135 230 215 230 275 230 315 230 39 145 135 145 215 145 275 145 315 145 135 215 275 315 215 275 315 315

1 60 48


(7 5 )  1 0 0

25 52 80

37 90

51

65

1 2 4 1 7 1 2 1 2

1 6 0 2 1 5 2 6 5

1 2 8 1 6 0

1 00 16 5 1 00 26 5 1 00 34 5 1 00
42 395 42 165 265 345 395 42 165 265 345 395 165 265 345 395 265 345 395 395

55 18
   

18 46 70 90

11 0

1 00 79 79 79 79 79 52 52 52 52 52 23 23 23 23
  

15
  

25
 

25 52 80

37 90

1 2 8 1 6 0

11 0

1 81 1 81 1 81 1 81 1 81

39


48


18
   

51

65

18 46 70 90

1 2 4 1 7 1 2 1 2

1 6 0 2 1 5 2 6 5

15
  

25 52 80

11 0   

81 81 81 81 81 31 31 31 31


  

25
 

37 122 105 122 165 122 206 122 238 122 105 165 206 238 165 206 238 238

39


48


18
       

37 90

51

65

18 46 70 90 18 46 70 90 46 70 90 90

1 2 4 1 7 1 2 1 2 

1 6 0 2 1 5 2 6 5 

1 2 8 1 6 0  

25 52 80

37 90

1 2 8 1 6 0

11 0

48 48 48 48


  

51

1 2 4 1 7 1 2 1 2

63 63 63 63


  

65

1 6 0 2 1 5

-2 6 5
1 6 0 2 1 5 2 6 5

 

52 80

33 33 33 80

90

40 40 40

1 2 4 1 7 1 2 1 2

50 50 50

12 12 12 45

  

1 2 8 1 6 0

11 0

55

11 0

1 6 0

1 0 5

2 1 2

1 3 5

2 6 5

Y2

Y1

Options
Dual SPDT microswitches Microswitches with gold plated contacts Flameproof microswitches Self checking proximity switches acc. to NAMUR Enclosure IP67, or IP68 for submersible applications 5A/380 VAC 0,3A/440 VDC (type: AE26) Flameproof switches, BASEEFA-, PTB-, SAA- and SEV-approved Pneumatic switches ON/OFF with 3/2 way valve High and low temperature versions Cable gland M24 x 1,5 Cable entry with 3/4" NPT internal thread Switch housing: - chromated - stainless steel (316 equiv.) - epoxy painted Flange modules: - acc. to ANSI, DIN, BS10 and JIS Float modules: - interface control

Counterflanges

The simplest method of installing TriMod BESTA level switches type A 01 090 to A 01 095 is to use the BESTA standard weld-on counter flanges. These are available in carbon steel C22.8 (A105) and in stainless steel 1.4401 (316 equivalent).

Temperature range: material C22.8: material 1.4401:

-10 C to +400 C -196 C to +400 C

30

V=38

92 x 92 M 12
76.1

Type 2829.1 2831.3

Specification Counterflange Counterflange

Flange material C22.8 1.4401

Stud material 5.8 A2

2 9 65

Certificates

Material certificates acc. to EN10204-2.2 and EN10204-3.1B Test records of hydraulic pressure tests and functional tests Test records of material tests: x-ray, ultra sonic, charpy, hardness etc.

Quality Assurance

BESTA AG is certified according to ISO 9001.

With reservation of technical modifications

LTDS03E/07.97

Ackerstrasse 45, CH-8610 Uster/Switzerland Phone +41-1-941 30 20, Fax +41-1-941 40 15 E-Mail: info@besta.ch http://www.besta.ch
Printed in Switzerland

TriMod BESTA Level Switches Horizontal Line Data Sheet LTDS02E TriMod BESTA level switches type: A 01 140 A 01 141 Top mounted level switches for level alarm or pump control applications
Nominal pressure Operating temperature Ambient temperature Density of liquid - pump control - alarm Operating differential S Wetside material Switch housing material Flange dimensions Counter flange Switch element Switch rating Cable gland Enclosure Weight Approvals PN 16 max. 16 bar to 300C max. 10 bar at 330C 0 to 330C 0 to 70C min. 0.45 kg/dm3 min. 0.30 kg/dm3 A 01 140: 12 to 1340 mm A 01 141: 12 to 2840 mm stainless steel (316 equiv.) sea water resistant die cast aluminium 92 x 92 mm (P.C.D. 92 mm) see overleaf microswitch changeover (SPDT) with silver contacts 5A/250 VAC 5A/30 VDC PG16 IP65 A 01 140: approx. 2.5 kg A 01 141: approx. 2.7 kg ABS, BV, DNV, GL, LRS, PRS, RINA, MRS
11 14 12 71 88 49

Connection diagram

1. For pump control (2 switch points) The required differential is set by fixing the two stop collars in the appropriate positions on the rod. The counterweight has to be adjusted to compensate for the rod weight (without float), until the cross arm is balanced. The float slides up and down the rod with the liquid level and actuates the switch at the set position of the stop collars. The switch remains latched between the two positions, which are for applications such as pump control where the contactor coil would need to remain energized throughout the pumping cycle. 2. For alarm operation (1 switch point) Only the lower collar is fixed on the for (below the float). Within the limit of the rod length, the height of the alarm point can be chosen as required. The counterweight has to be set, to outweigh the rod (without float). The alarm switching differential is 12 mm.
90
140 max. 45

39

Setting the switching differential

counter weight

68

13

stopcollar

50
A 01 140: 1582 L

Adjustment at factory
The level switches are factory set for pump control. Distance X = 38 mm. If the rods have to be shortened or the switch has to be used for alarm purposes, the position of the counterweight has to be adjusted, as described on the back page.

92 4 x 13 123
2 9

stopcollar

A 01 141: 3082

150

Distance X for counterweight (see drawing on the front page)


Switch types rod length L in (mm) ...140/...145 pump control X in (mm) ...140 / ...145 500 600 700 800 900 1000 1100 1200 1300 1400 1500 63 60 57 54 51 47 44 41 38 35 32 alarm X in (mm) ...140 45 42 39 36 32 30 26 23 20 17 14 ...145 4 4 4 4 4 4 4 4 4 4 4 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 Switch types rod length L in (mm) ...141/...146 pump control X in (mm) ...141 / ...146 54 53 51 49 48 46 44 43 41 39 38 36 34 33 31 29 alarm X in (mm) ...141 45 43 41 40 38 36 35 33 31 30 28 27 25 23 22 20 ...146 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

Installation

Over open tanks or sumps on a bracket. On closed tanks on the manhole covery with the float mounted from the inside. In the absence of a manhole, i.e. the float can not be mounted from the inside, an intermediate flange with an inside diameter of min. 125 mm of flange modules acc. to DIN DN125 or ANSI DN5" should be used. If turbulence occurs, the rod should be guided loosely at the lower end.

Counterflanges

76.1

Type 2829.1 2831.3

Specification Counterflange Counterflange

Flange material C22.8 1.4401

Stud material 5.8 A2

92 x 92 M 12

2 9 65

Options
Dual SPDT microswitches Microswitches with gold plated contacts Self checking proximity switches acc. to NAMUR Enclosure IP67, or IP68 for submersible applications 5A/380 VAC 0.3A/440 VDC (type: AE26) Explosion proof switches, BASEEFA-, PTB-, SAA- and SEV-approved Pneumatic switches ON/OFF

High and low temperature versions Cable gland M 24 x 1.5 Cable entry with 3/4" NPT internal thread Switch housing: - chromated - stainless steel (316 equiv.) - epoxy painted Flange modules: - acc. to ANSI, DIN, BS and JIS Float modules: - interface control

Certificates
Material certificates acc. to EN 10204-2.2 and EN 10204-3.1B Test records of hydraulic pressure tests and functional tests Test records of material tests: x-ray, ultra sonic, charpy, hardness etc.

Qualtiy Assurance
BESTA AG is certified according to ISO 9001.

With reservation of technical modifications

V=38

The simplest method of installing the TriMod BESTA level switch types A 01 140 and A 01 141 is to use the BESTA standard weldon counterflanges. These are available in carbon steel C22.8 (A105 equiv.) and in stainless steel 1.4401 (SS316 equiv.). If the float can be mounted from the inside, the counterflange can be welded directly to the tank. Otherwise the counterflange has to be welded to an intermediate flange (I.D. min. 125 mm).

Temperature range: Material C22.8 Material 1.4401:

-10 to +400C -196 to +400C

30

LTDS02E/07.97

Ackerstrasse 45, CH-8610 Uster/Switzerland Phone +41-1-941 30 20, Fax +41-1-941 40 15 E-Mail: info@besta.ch http://www.besta.ch