The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction
Component Raw material Positive plate Lead dioxide Negative plate Lead Container ABS Cover ABS Safety valve Rubber Terminal Copper Separator Fiberglass Electrolyte Sulfuric acid
General Features
q
Performance Characteristics Nominal Voltage 12V Number of cell 6 Design Life 10 years Nominal Capacity 77oF(25oC) 10 hour rate (5.5A, 10.8V) 55Ah 5 hour rate (9.23A, 10.5V) 46.15Ah 1 hour rate (35.1A, 9.6V) 35.1Ah Internal Resistance 5.8mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 550A(5s) Max. Discharge Current 77 F(25 C) Short Circuit Current 1400A Charge Methods: Constant Voltage Charge 77oF(25oC) Cycle use 2.30-2.35VPC Maximum charging current 16.5A Temperature compensation -30mV/oC Standby use 2.23-2.27VPC Temperature compensation -20mV/oC
q q q
q q
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge.
Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 229 / 9.01 138 / 5.43 208 / 8.18 213 / 8.38 18.5 / 40.8
451
10min 15min 30min 45min 238 225 213 200 186 185 177 169 162 154 111 109 107 105 104 85.3 84.0 82.3 80.5 78.4
(Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.
page1 of 2
www.vision-batt.com
6FM55T-X
Voltage Current
12V55Ah
Charged Volume
(%) (XCA) (V) 12.0 Battery voltage(V) 140 120 100 0.25 0.20 0.15 0.10 0.05 0 15.0 14.0 13.0 12.0 11.0 CHARGING CURRENT CHARGED VOLUME
13.9A 9.23A
9.6
5.5A
CHARGE VOLTAGE
80 60 40
118A
0
53A 35.1A
5 10 min
20 30
60
3 h
10
20
20 0
10
12
14
16
18
20
Discharge time
Self-discharge characteristic
110 100 Capacity(%) 90 80 70 60 50
-10
10
20
30
40
50
60
100
100 Capacity(%) 80 60 40 20 0 200 400 600 800 1000 Number of cycles(cycles) 1200 1400
Capacity(%)
80
60
40
20
6 Life(year)
-10
10
20
30
40
50( o C)
Temperature( oC)
ISO9001:2000