Vous êtes sur la page 1sur 9

0 REV.

Owner

20.12.2010 DATE

FOR APPROVAL DESCRIPTION

S.K.
DESIGNED BY

A.G.
PREPARED BY

F.E.E.
CHECKED BY

H.G
APPR. BY

G.S.P.L.A.J. MISURATA FREE ZONE ADMINISTRATION


Document No Micro Film No / CD No

Consultant

Project

MISURATA COMMERCIAL PORT


Designer Contractor

Unit

CONTAINER BERTH (BERTHS Nos 16-20)


Drawing Title

CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS


Designed By Prepared By Checked By Approved By

S.KAYA Page 9 Date 20.12.2010

A.GUNEYLI Project Code MBR-CP Stage E Doc. Type S

F.E.ERAS Const. Unit 000

H.GUNES
Doc. Sequence No 050 Rev. Code 0

Page 2

of

INDEX

1. 2. 3.

INTRODUCTION .................................................................................................................3 STANDARDS ......................................................................................................................4 CALCULATION ...................................................................................................................5 3.1. 3.2. Tensile Strength of Plate...........................................................................................5 Welding Calculation ....................................................................................................6 CONCLUSION ................................................................................................................8 ATTACHMENTS .............................................................................................................9

4. 5.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 3

of

1. INTRODUCTION

This document includes SS316 Anchor Plate calculations that will be used on MISURATA COMMERTIAL PORT CONTAINER BERTH.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 4

of

2. STANDARDS
AWS A5.9:06 TS EN ISO 14343-A:08 ASTM A240/A240M:09 EN10028-7:08 DIN 4100 TS 3357

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 5

of

3. CALCULATION
3.1. Tensile Strength of Plate As a construction material, 8 mm thick EN10028-7/08, WNR 1.4404/1.4401, ASTM A240/A240M-09 type 316 plates will be used. Material certificate is attached to this file.

The critical section for this load at top of the hole is; Area = A = 15 x 8 = 120 mm2 = 1,2 cm2 Load = P = 90 Kg (from MBR-CP-E-S-000-027 Rev.1) Yield Strength = = 205 MPa 2,05 t/cm2 (ASTM A240 A240M Table 2 for SS 316)

P 0.09 = 0,08t / cm 2 A 1.2

0,08 t/cm2 >> 2,05 t/cm2 O.K.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 6

of

3.2. Welding Calculation


Process will be carried out according to Welding Procedure Specification attached to this file.

According to DIN 4100 and TS3357 (Building Code for Design and Execution of Welded Connections) Section 2.2.1.1, welding thickness in fillet weld is; 3 a 0,7 tmin, If thickness of plate is 8 mm then, 3 a 5,6 mm.

a = te, b = 5 mm => a = 5 x 0,707 = 3,54 mm 3 3,54 5,6 mm O.K.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 7

of

Assuming P load is acting on weld b and e;

te = 3,54 mm = 0,354 cm A = Perimeter x te A = 2 x (9,2 + 0,8) x 0,354 A = 7,08 cm

P 0.09 = 0,013t / cm 2 A 7,08

Yield strength of welding wire is 4,2 t/cm2 (According to AWS A5.9:2006 and TS EN ISO 14343 A:8 and material certificate attached to this file) 0,013 t/cm2 < 4,2 t/cm2 O.K.

According to assumed welding area, calculated yield strength is much smaller than that of filler material. Because of that, there is no need to make further calculations for complete welding area.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 8

of

4. CONCLUSION
Anchor Plate designed to resist 90 Kg of force acting on anode hanging system caused by waves constructed from 316-quality stainless steel is convenient for aimed process according to calculations.

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Page 9

of

5. ATTACHMENTS

Project: Document Title: Revision:

MISURATA COMMERTIAL PORT CONTAINER BERTH CATHODIC PROTECTION SYSTEM ANCHOR PLATE CALCULATIONS 0 Date: 20.12.2010

Prj. Identification: Document No.: MBR-CP-E-S-000-050-0

Vous aimerez peut-être aussi