Vous êtes sur la page 1sur 8

MODEL:

STCH

CASE:

STCH

POWER:

41.16

HR:

0.00

EFF:

0.00

0.70 P T 211.00
16.40 W H 685.24

S2

6.20 P T 535.00
131.00W H836.49

S1

ST1

S4
GEN1

S3

0.01 P T 41.53
147.40 W H 550.94

GateCycle Report - Case Report


Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 1 of 8
11/19/2012 17:11

Overall System Results


Model ID
STCH
Case ID
STCH
Case Description
Power: -------------------------------------------------------------Shaft Power
Generator Output
Net Power
Steam Cycle 41792 kW
41165 kW
41165 kW
Gas Cycle 0.0 MW
0.0 MW
Plant Total
41.16 MW
Losses: - ----------------------------------------------------------Generator Losses Aux & BOP Losses
Steam Cycle 626.88 kW
0.0 kW
Gas Cycle 0.0 kW
0.0 kW
LHV Energy Input: --------------------------------------------------Total LHV Fuel Cons.
0.0 kcal/hr
Fuel Cons. in Duct Burners
0.0 kcal/hr
Efficiency:--------------------------------------------------------LHV Efficiency
LHV Heat Rate
Gas Turbine 0.0
Net Cycle 0.0
0.0 kcal/kW-hr
Adjusted 0.0
0.0 kcal/kW-hr
Credits Appliedfor AdjustedEff. & HR: ----------------------------Equivalent Power Equivalent Fuel
Credit
0.0 kW
0.0 kcal/hr
AmbientConditions:------------------------------------------------Dry Bulb
Wet Bulb
Dew Point
Temperature 15.00 C
10.86 C
7.30541 C
Absolute Pressure Equivalent Altitude
Pressure 0.1013 MPa
0.4518 m
Relative Humidity Water Mole Fraction in Air
Humidity 0.6000
0.0100904
User-DefinedVariables:--------------------------------------------Index
Description
Value
BOP Calculationsand Losses Settings:------------------------------Ignore Comp. Power Requ.
No
ST Generator Efficiency
0.9800
BOP Loss as ST Pwr Frac.
0.0
BOP Loss as Fixed Value
0.0 kW

file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

User Settings:-----------------------------------------------------Steam Property Method


1993 ASME steam property formula
Gas Property Method
JANAF Table data curves
Turn All Macros Off Flag
No
Use Perf. Factors Flag
No
Program Data: ------------------------------------------------------Case Design Mode
0
Execution Status
Converged
Iterations Used
5
Final Iteration Residual
0.0
System Tolerance
0.0001
Property Calcs. Tolerance
0.0001
Final Iteration Errors
0
Final Iteration Warnings
0
No. of Active Macros Used
0
Max. Macro Residual
0.0
Execution Time
00:00:02
--------------------------------------------------------------------GateCycle Report - Case Report
Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 2 of 8
11/19/2012 17:11

Overall System Results


Streams

From

To
Flow
Temperature Pressure Enthalpy
ton/hr
C
MPa
kcal/kg
-----------------------------------------------------------------------------S1
ST1
131.00
535.00
6.2
836.49
S2
ST1
16.40
211.00
0.7000
685.24
S3
ST1
147.40
41.53
0.008
550.94
-----------------------------------------------------------------------------GateCycle Report - Case Report
Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 3 of 8
11/19/2012 17:11

Overall System Results


Equipment/Ports
Flow
Temperature Pressure Enthalpy Quality
ton/hr
C
MPa
kcal/kg /x of CH
-----------------------------------------------------------------------------No flow through this equipment unit
S1 [SOURCE]: Source
file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

Outlet

131.000

535.00

S2 [SOURCE]: Source
Outlet
16.400
211.00
S3 [SINK]: Sink
Inlet
147.400

41.53

6.2
0.7000
0.008

836.49
685.24
550.94

1.0
1.0
0.8875

ST1 [ST]: Steam Turbine


Steam Inlet
131.000 535.00
6.2
836.49
1.0
Main Outlet
147.400 41.53
0.008
550.94
0.8875
Expansion Line End 147.400 41.53
0.008
550.94
0.8875
First Admission
16.400
211.00
0.7000
685.24
1.0
-----------------------------------------------------------------------------GateCycle Report - Case Report
Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 4 of 8
11/19/2012 17:11

Equipment ID: GEN1 Type: GENRTR Description: Generator


Main Inputs: -------------------------------------------------------Generator Efficiency Method Flag
Specified Generator Efficiency
Desired Overall Generator Efficiency
0.9850
Overall Generator Efficiency
0.9850
CurrentValues IncludingMargin:-----------------------------------Absolute Margin Losses for ST components
0.0 kW
Absolute Margin Losses for GT components
0.0 kW
Overall Generator Efficiency
0.9850
Overall Losses
626.88 kW
Shaft Power
41792 kW
Generator Terminal Power
41165 kW
Generator Reactive Power (kVAR)
25512
CurrentValues 0 Margin:-------------------------------------------Overall Generator Efficiency w/o Margin
0.9850
Overall Losses w/o Margin
626.88 kW
Generator Shaft Power w/o Margin
41792 kW
Generator Terminal Power w/o Margin
41165 kW
Generator Reactive Power (kVAR) w/o Margin 25512
Design Values:-----------------------------------------------------Generator Rating (kVA)
50000
Rating Coolant Pressure
0.5150 MPa
Generator RPM
3000.0

file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

GateCycle Report - Case Report


Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 5 of 8
11/19/2012 17:11

Equipment ID: S1 Type: SOURCE Description: Source


Flow
Temperature Pressure Enthalpy Quality
Ports:
ton/hr
C
MPa
kcal/kg /x of CH
----------------------------------------------------------------------------Outlet
131.000 535.00
6.2
836.49
1.0
----------------------------------------------------------------------------Inputs: ------------------------------------------------------------Calculation (flash) Method
Pressure - Temperature
CurrentValues:----------------------------------------------------Degrees of Superheat
257.30 C
Degrees of Subcooling
0.0 C
Heat Rate Adjustment:----------------------------------------------Flow does not affect adjusted heat rate calculations
--------------------------------------------------------------------GateCycle Report - Case Report
Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 6 of 8
11/19/2012 17:11

Equipment ID: S2 Type: SOURCE Description: Source


Flow
Temperature Pressure Enthalpy Quality
Ports:
ton/hr
C
MPa
kcal/kg /x of CH
----------------------------------------------------------------------------Outlet
16.400
211.00
0.7000
685.24
1.0
----------------------------------------------------------------------------Inputs: ------------------------------------------------------------Calculation (flash) Method
Pressure - Temperature
CurrentValues:----------------------------------------------------Degrees of Superheat
46.04 C
Degrees of Subcooling
0.0 C
Heat Rate Adjustment:----------------------------------------------Flow does not affect adjusted heat rate calculations
file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

--------------------------------------------------------------------GateCycle Report - Case Report


Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 7 of 8
11/19/2012 17:11

Equipment ID: S3 Type: SINK Description: Sink


Flow
Temperature Pressure Enthalpy Quality
Ports:
ton/hr
C
MPa
kcal/kg /x of CH
----------------------------------------------------------------------------Inlet
147.400 41.53
0.008
550.94
0.8875
-----------------------------------------------------------------------------

PressureControl:--------------------------------------------------Auto. Press. Control (Y/N)


Yes
Desired Pressure
0.008 MPa
Heat Rate Adjustment:----------------------------------------------Flow does not affect adjusted heat rate calculations
--------------------------------------------------------------------GateCycle Report - Case Report
Model: STCH Case: STCH
Prepared using GateCycle Version 5.61.0.r
Date & Time of Last Run
11/19/12
17:09
Last Execution Status
Converged

Item 8 of 8
11/19/2012 17:11

Equipment ID: ST1 Type: ST Description: Steam Turbine


Flow
Temperature Pressure Enthalpy Quality
Ports:
ton/hr
C
MPa
kcal/kg /x of CH
----------------------------------------------------------------------------Steam Inlet
131.000 535.00
6.2
836.49
1.0
Expans. Line End Pt. 147.400 41.53
0.008
550.94
0.8875
First Admission
16.400
211.00
0.7000
685.24
1.0
Section Exit
147.400 41.53
0.008
550.94
0.8875
----------------------------------------------------------------------------CurrentValues:----------------------------------------------------Net ST Section Power
41792 kW
Shaft/Gearbox Losses
0.0 kW
Current Gross Section Pwr
41792 kW
Current Overall Efficiency
0.9044
file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

Exergetic Efficiency

0.9182

Main Inputs: -------------------------------------------------------Design Efficiency Method


Isentropic Expansion Efficiency
User-Input Efficiency
0.9000
Design Press. Method
Throttle Pressure Set Upstream
Design Extraction Press. Method
Input Extraction Pressures
Design Exit Press. Method
No Exit Pressure Drop
Do NOT disable Crit. Pressure correction for modified stodola pressure calcs.
Pressure Stodola Cq AEN
K-Factor^2
Pressure Settings: MPa
in2
kg2/hr2-MPa/m3/kg
----------------------------------------------------------------------------Bowl
6.076
8580.4
7.61422 1.36725e+008
ConfigurationInputs: ----------------------------------------------Rotational Speed
3000
Default Stage Press. Ratio
0.8000
Shaft/Gearbox Loss Frac.
0.0
Design Blade Flow Angle
15.00
Design Reaction
0.0
Off Design Run Information:----------------------------------------Component was run in design mode
ST inlet: ----------------------------------------------------------No. of Control Valves
0
Control Valve DP
0.02
Current Control Valve Set.
1.0
Valve Constant (Kv)
59363
Throttle Flow Ratio
1.0
ST exit: -----------------------------------------------------------No. of Flow Ends
1
Exhaust Annulus Area
55.60 ft2
Current Annulus Velocity
0.0 m/hr
Volumetric Flow at ELEP
0.0 m3/hr
Volumetric Flow at ELEP per Flow End
0.0 m3/hr
Quality at ELEP
0.0
Exhaust Volumetric Flow
2.14851e+006 m3/hr
Exhaust Volumetric Flow per Flow End
2.14851e+006 m3/hr
MiscellaneousValues:----------------------------------------------Min. Allowed Exit Quality
0.8500
Max. Allowed Inlet Temp.
565.56 C
Efficiency Performance Factor
1.0
InternalValues:---------------------------------------------------Current Overall Efficiency
0.9044
Cur. Bowl-Last Extraction Eff.
0.8368
Cur. Bowl-ELEP Eff.
0.9000
Current Inlet S.V.
0.0576389 m3/kg
Current Bowl Pressure
6.076 MPa
file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]

Data for Stage Groups:


Group Stage 1 eff.
0.8368
Group Stage 1 Current PR
0.1152
There are 10 Stages in Group 1
Design Stage PR, Group 1
0.8057
Group 1 Stage Critical PR
0.0627989
Group Stage 1 Flow Coeff.
8580.4
---------------------------------------------------------------------

file:///C|/Users/CH/Documents/G-STCH.RPT.txt[11/19/2012 5:12:06 PM]