Académique Documents
Professionnel Documents
Culture Documents
IN ERICSSON for on cell: WE HAVE 6 TRX WITH CONCENTRATED SIGNALING and WE HAVE 11 TS FOR SPEECH (16K) and 4 TS for EDGE ( RES64K). also we have the cell with Numreqegprs=4
If the configuration is good, then you should not have any alarm( INSUFFICIENT EGPRS EQUIPMENT if you do RXCDP or ABIS PATH UNAVAIL when you do RXASP).
The abis resources are shared among all the cells on a site, so if you don't provide the information about the other cells, it will be impossible to judge whether the configuration is correct or not.
Regards, SHELDON
OMAR - 19 May 2011 THE SITE HAVE ONE CELL WITH 6 TRX
SHELDON - 20 May 2011 In that case, your configuration should be good, but verify with RXCDP and RXASP. If everything is alright, then there should be no alarm, as I mentioned in my previous post.
If you want a detailed calculation of the required abis capacity, pls provide the CONFACTOR and the number of SDCCH/8s in the cell.
Regards, SHELDON
" INSUFFICIENT EGPRS EQUIPMENT " Please confirm this alarm comes up when there is no free TS in allocated E1 for the site?
Suppose we have 6/6/6 site config with 3 SDs in each cell and confact is 2. What's going to be the suitable config. in terms of E1s?
Thanks,
"INSUFFICIENT EGPRS EQUIPMENT" will pop up when one or both of the following are true: 1. You have not defined the required number of abis timeslots 2. You have not opened the required DCP2s (8 on the EDGE TRX).
iii) Total Number of TCHs = 144 - 9(3SDs per sector *3) -3(BCCHs)= 132
iv) Total Number of Abis timeslots required for voice (TCHs) = 132*1/4 = 33 (remember each TCH requires 16kbps on the abis, which is 1/4 of the abis timeslot).
v) Total Number of abis timeslots for signalling = 18/2 =9 (18 being the total number of TRXs, 2 being your CONFACTOR).
Remember, however, that this excludes the number of EDGE timeslots, which you did not provide.
Regards
OMAR - 23 May 2011 NORMALY THE SD AND THE BCCH NEED A RESSOURCE IN THE ABIS
Precisely explained by you. We are using 4 edge TSs mostly, so if we add 4 edge TSs here in your calculation, what it would result then?
Thanks,
Optim
SHELDON - 24 May 2011 Hi Optim, Four EDGE timeslots per cell gives a total of 12 extra abis timeslots.
But then you will have to subtract 12 from iii), before you find the abis capacity for the voice.
Therefore, total Number of Abis timeslot needed for the site = 30+9+12 = 51
@Omar, No, the BCCH and SDCCH don't need a separate resource on the abis. They form part of the signalling, which I included in the calculation.
HI SHELDON
CAN YOUR GIVE ANY INFORMATION FOR EDGE SINALING CONSIDERATION FOR ABIS CONFIGURATION
I need little more info. from you, which is, hoW one can see the no. of E1s a site has been configured with? I mean some fast procedure than RXAPP?
Thank,
Optim
Rgds
For your ex: Total TRX= 6 * 3 =18 confact =2 EDGE TS=12 Abis TS= (18*2)+(18/2)+12= 57
What Sheldon has done, logically looks perfect, 'each TCH requires 1/4 of ABIS TS' So with this in mind, total # of Abis TSs = 51 is perfect.
While NJs formula is good and precise toOo, but it includes SDCCHs in the calculation hence requiring few more Abis TSs.
Also as I heard that one 4/4/4 site requires exactly 1 E1, so based on this, NJ's formula looks fine.
Thanks,
there is a major difference between NJ and Sheldon computations. NJ assumes that 1 TRX uses 2 full Abis TS (= 8 Abis nibbles). Sheldon assumes that 1 TRX uses only as many Abis nibbles as the number of TCH on that TRX. For examlple 1 TRX with 1 BCCH + 1 SDCCH + 6 TCH would use only 6 abis nibbles = 1.5 Abis timeslot.
Both could be true, because it only depends on the E/// implementation. In ALU case, NJ would be right. In E/// case, I don't know. Both are possible. SHELDON - 7 Jun 2011 In ericsson, all the signalling(BCCH, SDCCH, PAGING, FACCH, SACCH) go through separate timeslots on the abis. That is why concentration is done. In that sense, it would be incorrect to assume that each TRX uses 2 abis timeslots.
In my network, each site is typically 4/4/4. We have 2 EDGE timeslots per cell,2 SDCCHs per cell and a CONFACTOR of 4. Yet we use only one E1 per site.
From the begining, I said it is a simple calculation, it depends on your Abis ressources but for us 2EDGE TS/cell aren't enough and Confact 4 have more risk of Signaling congestion.