Wind Analysis for Low-rise Building, Based on ASCE 7-98


INPUT DATA
Exposure category (A, B, C or D)
Importance factor, pg 55, (0.87, 1.0 or 1.15)
Basic wind speed
Topographic factor (Sec.6.5.7.2, pg 29 & 39)

I
V
Kzt
he
hr
L
B
A

Building height to eave


Building height to ridge
Building length
Building width
Effective area of components

=
=
=
=
=
=
=
=
=

B
1.00
90
1
35
39
100
60
50

Category II
mph
Flat
ft
ft
ft
ft
ft2

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal force at wind with any angle to building
Max total upward force

=
=
=
=

39.00
22.20
39.00
60.48

kips
kips
kips
kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2 I
where:

13.08

psf

qh = velocity pressure at mean roof height, h. (Eq. 6-13, page 30)


Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-5, Case 1,pg 60)

Kd = wind directionality factor. (Tab. 6-6, for building, page 61)


h = mean roof height

=
=

0.74
0.85
37.00 ft
< 60 ft, [Satisfactory]

Design pressures for MWFRS

p = qh [(G Cpf )-(G Cpi )]


where:

p = pressure in appropriate zone. (Eq. 6-16, page 32).


G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 6-4, page 43)
G Cp i = product of gust effect factor and internal pressure coefficient. (Tab. 6-7, Enclosed Building, page 62)
=
0.18
or
-0.18
a = width of edge strips, Fig 6-4, note 7, page 43, (IBC 1609.6.3), MAX[ MIN(0.1B, 0.4h), 0.04B,3] =

Net Pressures (psf), Case A


Roof angle q =
Surface

1
2
3
4
1E
2E
3E
4E

G Cp f

0.42
-0.69
-0.39
-0.31
0.64
-1.07
-0.56
-0.47

Net Pressures (psf), Case B


7.59

Net Pressure with

(+GCp i )
3.17
-11.38
-7.44
-6.46
6.05
-16.35
-9.65
-8.45

(-GCp i )
7.88
-6.67
-2.73
-1.76
10.76
-11.64
-4.94
-3.74

Roof angle q = 0.00


G Cp f

0.40
-0.69
-0.37
-0.29
0.61
-1.07
-0.53
-0.43

Net Pressure with

(+GCp i )
2.88
-11.38
-7.19
-6.15
5.62
-16.35
-9.29
-7.98

(-GCp i )
7.59
-6.67
-2.48
-1.44
10.33
-11.64
-4.58
-3.27

Surface

G Cp f

1
2
3
4
5
6
1E
2E
3E
4E
5E
6E

-0.45
-0.69
-0.37
-0.45
0.40
-0.29
-0.48
-1.07
-0.53
-0.48
0.61
-0.43

Net Pressure with

(+GCp i ) (-GCp i )
-8.24
-11.38
-7.19
-8.24
2.88
-6.15
-8.63
-16.35
-9.29
-8.63
5.62
-7.98

-3.53
-6.67
-2.48
-3.53
7.59
-1.44
-3.92
-11.64
-4.58
-3.92
10.33
-3.27

6.00

ft

Case A @ (a) CORNER I


Surface

1
2
3
4
1E
2E
3E
4E
S
10 psf min.
Sec. 6.1.4.1

Area
(ft2)

3080
2663
2663
3080
420
363
363
420
Horiz.
Vert.
Horiz.
Vert.

Case A @ (b) CORNER II

Pressure (k) with

(+GCp i )
9.77
-30.30
-19.82
-19.91
2.54
-5.94
-3.50
-3.55
34.06
-59.04
39.00
-60.00

Surface

(-GCp i )
24.27
-17.76
-7.28
-5.41
4.52
-4.23
-1.79
-1.57
34.06
-30.79
39.00
-60.00

1
2
3
4
1E
2E
3E
4E
S
10 psf min.
Sec. 6.1.4.1

Case B @ (a) CORNER I


Surface

1
2
3
4
5
6
1E
2E
3E
4E
5E
6E
S
10 psf min.
Sec. 6.1.4.1

Area
2

(ft )

3080
2663
2663
3080
2008
2008
420
363
363
420
212
212
Horiz.
Vert.
Horiz.
Vert.

Area

Pressure (k) with

(ft2)

1790
2421
2421
1790
430
605
605
430
Horiz.
Vert.
Horiz.
Vert.

(+GCp i )
5.15
-27.55
-17.42
-11.01
2.42
-9.90
-5.62
-3.43
22.00
-59.95
22.20
-60.00

(-GCp i )
13.58
-16.15
-6.02
-2.58
4.44
-7.05
-2.77
-1.40
22.00
-31.70
22.20
-60.00

Case B @ (b) CORNER II

Pressure (k) with

(+GCp i )
-25.38
-30.30
-19.16
-25.38
5.78
-12.34
-3.63
-5.94
-3.37
-3.63
1.19
-1.69
21.01
-58.77
22.20
-60.00

Surface

(-GCp i )
-10.88
-17.76
-6.62
-10.88
15.23
-2.89
-1.65
-4.23
-1.66
-1.65
2.19
-0.69
21.01
-30.27
22.20
-60.00

1
2
3
4
5
6
1E
2E
3E
4E
5E
6E
S
10 psf min.
Sec. 6.1.4.1

Area

Pressure (k) with

(ft )

1790
2421
2421
1790
3290
3290
430
605
605
430
210
210
Horiz.
Vert.
Horiz.
Vert.

(+GCp i )
-14.75
-27.55
-17.42
-14.75
9.47
-20.22
-3.71
-9.90
-5.62
-3.71
1.18
-1.68
32.55
-60.48
39.00
-60.00

(-GCp i )
-6.32
-16.15
-6.02
-6.32
24.96
-4.73
-1.69
-7.05
-2.77
-1.69
2.17
-0.69
32.55
-31.98
39.00
-60.00

Design pressures for components and cladding

p = qh[ (G Cp) - (G Cpi)]


where:

p = pressure on component. (Eq. 6-18, pg 32)


pmin = 10 psf (Sec. 6.1.4.2).
G Cp = external pressure coefficient.
see table below. (Fig. 6-5, page 44 ~ 47)

Effective
Area (ft2)
Comp.

50

Comp. & Cladding


Pressure
( psf )

Zone 1
GCP
- GCP

0.23

-0.93

Zone 1

GCP

Zone 2
- GCP

GCP

Zone 3
- GCP

0.23

-1.31

0.23

-1.61

Zone 2

Zone 3

Zone 4
GCP
- GCP

Zone 5
GCP
- GCP

0.79
-0.88
0.79
-1.04
(Walls reduced 10 %, Fig. 6-5A note 5.)
Zone 4

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

10.00

-14.52

10.00

-19.50

10.00

-23.43

12.67

-13.85

12.67

-15.93

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Building with h > 60 ft, Based on ASCE 7-98
INPUT DATA
Exposure category (A,,B, C or D)
Importance factor (0.87, 1.0 or 1.15)
Basic wind speed
Topographic factor (Sec.6.5.7.2)
Building height to roof
Parapet height
Building length
Building width
Effective area of mullion

I
V
Kzt
H
HP
L
B
AM

=
=
=
=
=
=
=
=
=

B
1.00
90
1
108
0
100
50
55

Effective area of panel

AP

27

Category II, page 55


mph
Flat, page 29 & 39
ft
ft
ft
ft
2
ft
2

ft

DESIGN SUMMARY
Max building horizontal force normal to building length, L, face
Max base moment at wind normal to building length, L, face
Max building horizontal force normal to building length, B, face
Max base moment at wind normal to building length, B, face
Max building upward force
Max building torsion force

=
=
=
=
=
=

187.7
11595.0
77.5
5234.5
78.7
586.6

kips
ft - kips
kips
ft - kips
kips
ft - kips

ANALYSIS
Velocity pressures

qz = 0.00256 Kz Kzt Kd V2 I
where:

qz = velocity pressure at height, z. (Eq. 6-13, page 30)


Kz = velocity pressure exposure coefficient evaluated at height, z. (Tab. 6-5, Case 2, page 60)
Kd = wind directionality factor. (Tab. 6-6, for building, page 61)
z = height above ground

0.85

z (ft)
Kz

0 - 15

20

25

30

40

50

60

70

80

90

100

108

0.57

0.62

0.66

0.70

0.76

0.81

0.85

0.89

0.93

0.96

0.99

1.01

qz (psf)

10.05

10.93

11.63

12.34

13.40

14.28

14.98

15.69

16.39

16.92

17.45

17.80

z (ft)
Kz

108

108

108

108

108

108

108

108

108

108

1.01

1.01

1.01

1.01

1.01

1.01

1.01

1.01

1.01

1.01

qz (psf)

17.80

17.80

17.80

17.80

17.80

17.80

17.80

17.80

17.80

17.80

0.18

or

Design pressures for MWFRS

p = q G Cp - qh (G Cpi)
where:

p = pressure on surface for rigid building with all h. (Eq. 6-15, page 31).
q = qz for windward wall at height z above the ground, see table above.
G Cp i = internal pressure coefficient. (Tab. 6-7, Enclosed Building, page 62)

qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
G = gust effect factor for rigid (Sec. 6.5.8.1, Page 29) =
Cp = external pressure coefficient, see right down tables.

Fig. 6-3 fo q < 10o, page 42

0.85
Roof
To L Face
To L Face
To L Face
To L Face

Roof
To B Face
To B Face
To B Face
To B Face

h/B

Distance

Cp

2.16
2.16
2.16
2.16
h/L
1.08
1.08
1.08
1.08

50
50
50
50
Distance
54
100
100
100

-1.04

Cp
-1.04
-0.70

Fig. 6-3, page 42


Wall
Windward Wall

q G Cp Figure for Gable, Hip Roof, page 41

Direction
All

L/B
All

Cp
0.80

Leeward Wall

To L Dir

0.50

-0.50

Leeward Wall
Side Wall

To B Dir
All

2.00
All

-0.30
-0.70

-0.18

(cont'd)
Hence, MWFRS Net Pressures are given by following tables (Sec. 6.5.12.3, Page 32)

Windward Wall

Surface

z (ft)

P (psf) with
GCPi
- GCPi

0 - 15
20
25
30
40

3.63
4.23
4.71
5.19
5.90

50
60
70
80
90
100
108

Surface

z (ft)

10.04
10.64
11.11
11.59
12.31

Side Wall

All

Surface

z (ft)

6.50
6.98
7.46
7.94
8.30

12.91
13.39
13.87
14.35
14.71

Leeward

All

8.66
8.90

15.07
15.31

Normal to L Face

Normal to L Face

Surface

Dist. (ft)

0 - 50

P (psf) with
GCPi
- GCPi
-13.80

-7.39

P (psf) with
GCPi
- GCPi
-10.77

-4.36

P (psf) with
GCPi
- GCPi
-18.94

Normal to B Face

Surface

z (ft)

Leeward

All

Normal to B Face

Surface

-12.53

Roof

Roof

Dist. (ft)

0 - 54
100

P (psf) with
GCPi
- GCPi
-7.74

-1.34

P (psf) with
GCPi
- GCPi
-18.94
-13.80

-12.53
-7.39

Figure 6-9, page 54


Base Forces

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Wind with Angle


Case 3
Case 4

ASCE-7

VBase

(kips)

188

164

78

68

152

133

MBase

(ft - kips)

11595

10149

5235

4581

9541

8336

Fig. 6-9

TBase

(ft - kips)

587

242

475

Page 54

FUpward (kips)

79

69

67

58

77

68

(kips)

108

108

54

54

122

121

Sec. 6.1.4.1

FUp,min (kips)

50

50

50

50

50

50

( 10 psf )

Vmin

Design pressures for components and cladding

p = q (G Cp) - qi (G Cpi)
where:

p = pressure on component for building with h > 60 ft. (Eq. 6-19, page 32).
pmin = 10 psf (Sec. 6.1.4.2, page 23).
q = qz for windward wall at height z above the ground, see table above.
qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
G Cp i = internal pressure coefficient. (Tab. 6-7) =
a = Zone width = MAX[ MIN(0.1B, 0.1L), 3] =
5.0
G Cp = external pressure coefficient. (Fig. 6-8, page 53)
Wall
Comp.

Actual Effective
Area ( ft2 )

Mullion
Panel

z (ft)

0 - 15
20
25
30
40
50
60
70
80
90
100
108

55
27

0.18
or
-0.18
ft, (Fig 6-8 note 8, pg 53)

Zone 4
GCP
- GCP

GCP

- GCP

0.81
0.87

0.81
0.87

-1.55
-1.73

-0.84
-0.88

Zone 5

Mullion Pressure (psf)


Zone 4
Zone 5

Panel Pressure (psf)


Zone 4
Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

10.00
10.77
11.47
12.16
13.20
14.07
14.77
15.46
16.16
16.68
17.20
17.55

-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11
-18.11

10.00
11.50
12.24
12.98
14.09
15.02
15.76
16.50
17.24
17.80
18.36
18.73

-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77
-30.77

10.57
11.50
12.24
12.98
14.09
15.02
15.76
16.50
17.24
17.80
18.36
18.73

-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89
-18.89

10.57
11.50
12.24
12.98
14.09
15.02
15.76
16.50
17.24
17.80
18.36
18.73

-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92
-33.92

cont'd

Components and Cladding

Roof

Effective
Area ( ft2 )

Zone 1

Components and Cladding

Zone 3

- GCP

- GCP

- GCP

-1.40

-2.30

-3.20

10

-1.40

-2.30

-3.20

59

-1.17

-1.98

-2.79

108

-1.10

-1.87

-2.65

157

-1.05

-1.81

206

-1.01

-1.76

255

-0.99

-1.72

304

-0.96

-1.69

353

-0.94

-1.66

402

-0.93

-1.64

451

-0.91

500

-0.90

3600

-0.90
3600

Roof

Zone 2

Effective
Area ( ft2 )

400

75

Net Pressure (psf)


Zone 1

Zone 2

Zone 3

-28.13

-44.15

-60.17

10

-28.13

-44.15

-60.17

59

-24.09

-38.49

-52.90

108

-22.71

-36.57

-50.42

157

-21.86

-35.38

206

-21.24

-34.51

255

-20.76

-33.83

304

-20.36

-33.27

353

-20.02

-32.80

402

-19.72

-32.38

451

-19.46

500

-19.23

3600

-19.23

Vous aimerez peut-être aussi