Vous êtes sur la page 1sur 10

Catalog ACDC Surge Protectors - Blue Series

MULTI-STAGE

Surge Protection
CLASS I+II+III
Innovated Multi-Stage Surge Protection Single & Three Phase Modular Installation - Hard Wire Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire IEC61643-1 Class I+II+III; IEC60939-2

Mobile Base Station Broadcast Computers

Telecommunication

Sensitive Electronic

Surge
Protection

Medical Equipment

Military

Hard Wire Installation


Industrial

Eight (8) Stages Surge Protector


Residental
NEW INNOVATION APPROACH TO SURGE PROTECTION
GREEN POWER SUPPLY

. . . We Care for Safety of Your Electronic Devices

This catalogue is the part of the Main Catalogue of ACDC DCAC Company Catalog ACDC Surge Protectors - Multi Stage Surge Protection

We reserve the right to introduce changes in performance, dimensions and material in the course of technical progress.

MULTI-STAGE SURGE PROTECTION

SurGe

ACDC SURGE PROTECTOR


EIGHT (8) STAGES SERIES PROTECTOR 1/1 & 3/3
HARD WIRE INSTALLATION - MODULAR SYSTEM
CLASS LPZ IP

Type-PI (780; 7100; 7125; 7200) Blue Series


Single Phase / Three Phase CLASS I+II+III Voltage Rating: 120VAC /230VAC /400VAC Current Rating: up to 100A per phase Response Time: < 1ns

I+II+III

0 1 2 3

20

home

telecom

IT center

industry

SurGe Protection

ACDC Surge Protector Type- PI Series


is specifically designed to protect, upgrade and improve functioning of computers, telecommunication, medical, audio, video and all sensitive electronic equipment.

ACDC Surge Protector Type - PI (780; 7100; 7125; 7200) Blue Series is advanced multi-stage surge protector consists of 8 (eight) & 100A protection stages that provides effective and reliable protection against surges and transients. The protection device have high grade cascade bidirectional EMI/RFI filtering of phase (L) wire with option for ground (Gnd) filtering. The protector has also special diagnostic for ground condition. Application: The scope of applications of ACDC Surge Protectors is quite wide and refers to the protection of electrical devices against impulse surge and high-frequency (electromagnetic) disturbance, oscillation, speaks in network power supply and atmospheric discharge. ACDC protectors have high-grade bidirectional filtering. They are tracking AC waveform eliminating so-called pollution in power AC supply. These protectors have special design to protect and improve functioning of sophisticate equipment in Telecommunications, Broadcast, Medical equipment, Computers, Military, Solar Photovoltaic and Residental. Technical Specifications: The basic module of type ACDC Surge Protector Blue Series is 8 (eight) stages Single Phase Protector with modular configuration for single or three phase applications for load currents of up to 100A (22kW) per phase. Investment: Installation of ACDC Surge Protector type - PI is excellent choice for investment in the quality of your power network supply, extended equipment life and reduce their down time and errors. Reliability: If the stages 2,4 and 6 are out of function, the stages 1,3 and 7 are still provide a high grade cascade bi-directional filtering along with ultimate (5-th) protection stage.
www.acdc-dcac.eu

igh current capability, up to 100A, makes these protectors ideal equally for low power sensitive electrical devices and for industrial application.

EASIER SIMPLER BETTER


Implementation of ACDC Surge Protectors is simple and easy. Regarding multi-stage design of Class I+II+III in one unit with ACDC Surge Protectors is expel need of several surge protectors installed separately in each boundary protection zone (LPZ0a/LPZ0b-LPZ3 & C-A acc. IEC 62305-4 & ANSI/IEEE C62.41.1-2)

ith simple words, design and planning of surge protection is not any more reserved just for experts in this field. It become simple and applicable to wide branch of professions: electrician, const. builders, IT..

Empowered by Innovation

Technical Specification Type - PI Blue Series

SurGe

MULTI-STAGE SURGE PROTECTION

EIGHT PROTECTION STAGES:


Cascade bi-directional EMI-RFI filtering of phase (L) and ground (GND) wire

Basic Circuit Diagram per Phase - Blue Series:


LIN for parallel application
Red Yellow Green

LIN for series application

LOUT
Var. C Bi-directional Filter (No back EMF effect)

ACDC Surge Protector Type-PI Blue Series


N

Var. C Bi-directional Filter (No back EMF effect) C

TVS Limiter
Thermal Cut-Off Control GTD

Thermal Cut-Off

Control GTD

GTD

N
without filtering

GND IN

GND IN for ground filtering


82 45

for ground filtering

GND OUT

36

In order to provide the optimum level of protection, ACDC has developed integrate 8 (eight) stages Surge protector that provides effective and reliable protection against surges and transients. Approach: ACDC Surge Protectors provides a systematic approach on two fronts: Surge protection and Bi-directional filtration. While there are companies and products that attempt one of these, ACDC Surge Protectors is the only product that seamlessly merges the two technologies. The unique multi-stage design provides the most advanced power filter protector. Technology: ACDC Surge Protector Type-PI Blue Series is protector of class I+II+III in one according to IEC61643. They also full fill standard requirements for electromagnetic (radio) interference IEC60939-2. Design: The integrated modular design for single or three phase applications alloweasy installation on place where surge protection are needed. Installation: The ACDC Surge Protector - Blue Series could be install in series or parallel configuration depending of total load (>100A<). The place of installation could be Main Circuit Board (MCB) or Sub Distribution Board (SDB).
acdc-dcac@acdc-dcac.eu

SIDE VIEW

50

Philosophy: The ACDC Surge Protectors have coordinated approach to lightning protection, surge and transient protection as well as grounding, an approach that embraces all aspects of potential damage. No single technology can effective protect electronic devices from the damaging effects of lightning and induced transients, which can severely damage or destroy electronic systems.

72

18

70

TOP VIEW

Innovation Approuch to Surge Protection


ACDC Multi-Stage Surge Protectors have built-in five (5) patents and use four (4) complementary different protection technologies, (Varistor, Gas Tube, Nanocrystalline Cores and TVS technology) in one unit. That result with reducing the surge current up to 99.9% at single point.

his characteristic can not offer competitive surge products and present a fundamental improvement in Surge Protection technology. Implementation of ACDC Surge Protectors aresimple and applicable for professions such as planners, construction engineers, designers, electricians and others.

New materials, New design, New approach to Surge Protection Industry

MULTI-STAGE SURGE PROTECTION

SurGe

Technical Specification Type - PI Blue Series

Technical Specification per Phase ACDC Surge Protector - Blue Series


Type Order Code Total Surge Current Product Standard

Type PI 780 - BS
800.125
Surge Cur. 105kA (8/20s) or 15kA (10/350s)

Type PI 7100 - BS
800.126
Surge Cur. 125kA (8/20s) or 18kA (10/350s)

Type PI 7125 - BS
800.127
Surge Cur. 150kA (8/20s) or 22kA (10/350s)

Type PI 7200 - BS
800.128
Surge Cur. 225kA (8/20s) or 32kA (10/350s)

IEC61643-1 Class I+II+III (B+C+D); IEC60939-2 First Protection Stage


Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction; L=4.2mH; Imax=up to 100A Nano Crystalline Core (L-C configuration)

1. Stage
Function Technical Specification Technology

2. Stage
Function Technical Specification Technology
Surge Cur. 80kA (8/20s) or 12,5kA (10/350s)

Second Protection Stage


Suppression signal shape (L-N), 8/20s or 10/350s
Surge Cur. 100kA (8/20s) or 15kA (10/350s) Surge Cur. 125kA (8/20s) or 20kA (10/350s) Surge Cur. 200kA (8/20s) or 30kA (10/350s)

Varistor with thermal cut-off; Control Gas Tube Discharge

3. Stage
Function Technical Specification Technology

Third Protection Stage


Bi-directional filtering EMI/RFI (L-N); Front signal edge reduction L=0.7mH; Imax=up to 100A Nano Crystalline Core (L-C configuration)

4. Stage
Function Technical Specification Technology

Fourth Protection Stage


Suppression signal shape (L-N), 8/20s Surge Cur. 25kA (8/20s) Varistor with thermal cut-off

5. Stage
Function Technical Specification Technology

Fifth Protection Stage


Long term signal suppression from 1s to 2 sec.
This stage is the last ultimate protection level. He switch-off the circuits breaker install upstream, if the pick voltage > 300DC for (120 VAC) or 520VDC for (230 VDC) appears on the output. Circuits breaker should be < 250A gl/gG.

Controlled Gas Tube Discharge

6. Stage
Function Technical Specification Technology

Sixth Protection Stage


High speed efficiency signal suppression TVS Limiter 500A (8/20s); Typical response < 1nsec (nanosecond) Transient Voltage Suppressor

7. Stage
Function Technical Specification Technology

Seventh Protection Stage


Ground filtering L=0,7mH Nano Crystalline Core (L-C configuration)

8. Stage
Function Technical Specification Technology
Surge Cur. 80kA (8/20s) or 12,5kA (10/350s)

Eight Protection Stage


Suppression signal shape (N-Gnd), 8/20s or 10/350s
Surge Cur. 100kA (8/20s) or 15kA (10/350s) Surge Cur. 125kA (8/20s) or 20kA (10/350s) Surge Cur. 200kA (8/20s) or 30kA (10/350s)

Controlled Gas Tube Discharge

www.acdc-dcac.eu
Integrated Multi-Stage Protection www.acdc-dcac.eu

Models of Surge Protectors Type - PI Blue Series

SurGe

MULTI-STAGE SURGE PROTECTION

Single and Three phase Models - ACDC Surge Protectors - Blue Series
Guideline for ordering of ACDC Surge Protectors of Blue Series
Technology: Specification: Load: Options: Installation: Product Standard: Multi-Stage Surge Protection; Eight (8) Stages Series Protector Cascade bi-directional EMI-RFI filtering of phase (L) wire and ground (GND) wire Up to 100A per phase; 12kW per phase for 120VAC; 22kW per phase for 230VAC Ground filtering, indication for bed grounding, remote alarm Hard wire installation - Modular System

IEC61643-1 Class I+II+III; IEC60939-2


For upgrade the distribution panel Type
Type-PI 780 1/1-BS Type-PI 7100 1/1-BS Type - PI 7125 1/1-BS Type - PI 7200 1/1-BS

Single Phase

Order Code
800.125-1/1 800.126-1/1 800.127-1/1 800.128-1/1

Total Surge Cur.


105kA(8/20s) or 15kA(10/350s) 125kA (8/20s) or 18kA (10/350s) 150kA (8/20s) or 22kA (10/350s) 225kA (8/20s) or 32kA (10/350s)

Dimension
(WxDxHmm)

Weight
(kg)

82x72x70 82x72x70 82x72x70 82x72x70

0,47 0,47 0,47 0,47

Three Phase

For upgrade the distribution panel Three single phase surge protectors connected for three phase application Type
Type-PI 780 1/1-BS x 3 Type-PI 7100 1/1-BS x 3 Type - PI 7125 1/1-BS x 3 Type - PI 7200 1/1-BS x 3

Order Code
800.125-1/1 x 3 800.126-1/1 x 3 800.127-1/1 x 3 800.128-1/1 x 3

Total Surge Cur.


315kA(8/20s) or 45kA(10/350s) 375kA (8/20s) or 54kA (10/350s) 450kA (8/20s) or 66kA (10/350s) 675kA (8/20s) or 96kA (10/350s)

Dimension
(WxDxHmm)

Weight
(kg)

82x216x70 82x216x70 82x216x70 82x216x70

1,41 1,41 1,41 1,41

Three Phase

The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Type
Type-PI 780 3/3-M-BS Type-PI 7100 3/3-M-BS Type - PI 7125 3/3-M-BS Type - PI 7200 3/3-M-BS

Order Code
800.125-3/3-M 800.126-3/3-M 800.127-3/3-M 800.128-3/3-M

Total Surge Cur.


315kA(8/20s) or 45kA(10/350s) 375kA (8/20s) or 54kA (10/350s) 450kA (8/20s) or 66kA (10/350s) 675kA (8/20s) or 96kA (10/350s)

Dimension
(WxDxHmm)

Weight
(kg)

250x250x150 250x250x150 250x250x150 250x250x150

5,1 5,1 5,1 5,1

Three Phase

The Surge Protectors are installed in Metal Distribution board with degree of protection IP54 Circuit breakers MCB 100A are installed in the front of protectors for each phase Type
Type-PI 780 3/3-MCB-BS Type-PI 7100 3/3-MCB-BS Type - PI 7125 3/3-MCB-BS Type - PI 7200 3/3-MCB-BS

Order Code
800.125-3/3-MCB 800.126-3/3-MCB 800.127-3/3-MCB 800.128-3/3-MCB

Total Surge Cur.


315kA(8/20s) or 45kA(10/350s) 375kA (8/20s) or 54kA (10/350s) 450kA (8/20s) or 66kA (10/350s) 675kA (8/20s) or 96kA (10/350s)

Dimension
(WxDxHmm)

Weight
(kg)

300x250x150 300x250x150 300x250x150 300x250x150

7,1 7,1 7,1 7,1

* The Surge Protectors from series Type-PI 3/3-MBC-BS are delivered without ground filtering as model basic option. By customer request the model could be delivered for installation with ground filtering or for parallel installation with additional mark GF or P

www.acdc-dcac.eu
acdc-dcac@acdc-dcac.eu ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia Phone: 389 2 3216 988; Fax: 389 2 3216 993

MULTI-STAGE SURGE PROTECTION

SurGe

Operation Diagnostic Application

Operation Diagnostic System


Normal:
Continuous yellow and green
Red Yellow Green
Led Indication for correct stage no. 2,4 and 6. The stages no. 1,3 and 7 (high garde bi-directional filtering) are always in function along with ultimate (5-th) protection stage. Led Indication for correct stage no. 4,6 and un correct no 2. The stages no. 1,3 and 7 (bi-directional filtering) are always in function along with ultimate (5-th) protection stage.

Fault:
Continuous green

Fault:
Blinking red
Led Indication for bed grounding (Low impedance equipotential ground is not provided)

Fault:
Continuous red
Only stages 1,3 and 7 are still in function along with ultimate (5-th) protection stage.

Frequency attenuation:
- 10dB
0

- 40dB

- 80dB

-20

-40

-60

-80

10

100

1k

10k

100k

0.1

1k

10k

100k

800k

1M

Application:

Home

Mobile Base Station

Voltage Spike
U(V)

Safe Power Supply

Telekom

Uef

10

15

20

t (ms)

Industry
Random Noice Waveform Tracking Filter

Solar

Wind energy

Applications:
Certificate of Quality ISO 9001:2008 Varistors Standard IEC 61643-1; UL 1449 Elect. Magn. Interfer. IEC 60939-2 Protec. Standard acc. IEC 61643-1 Class I+II +III Telecommunication Medical equipment Military Computers Sensitive electronic Solars Industrial grade

Features:
Multi - Stage Surge Protection Eight (8) Protection Stages Bi-directional Filtering Ground Filtering Thermal Circuit Protection High Reliability Excellent Response Time < 1ns

Integrated Multi-Stage Protection

www.acdc-dcac.eu

Installation Instruction Type - PI Blue Series

SurGe

MULTI-STAGE SURGE PROTECTION

Installation Instruction for TN-C-S, TN-S and TT distribution system


SERIES - Single Phase Installation with phase (L) and ground (GND) filtering
Fuse

SERIES - Three Phase Installation with phase (L) and ground (GND) filtering
L1 L2
Fuse Fuse Fuse

L N PE

L3 N PE

LIN

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

LIN

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

ACDC SURGE PROTECTOR

Blue

Series

ACDC SURGE PROTECTOR

Blue

Series

ACDC SURGE PROTECTOR

Blue

Series

GND II IV,VI

Type - PI Blue Series Load Rating: 230VAC @ 100A

GND II IV,VI

Type - PI Blue Series Load Rating: 230VAC @ 100A

GND II IV,VI

Type - PI Blue Series Load Rating: 230VAC @ 100A

GND II IV,VI

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

mark

mark

mark

mark

GIN GOUT

GIN GOUT N

GIN GOUT N

GIN GOUT

SERIES - Single Phase Installation with phase (L) and without ground (GND) filtering
Fuse

SERIES - Three Phase Installation with phase (L) and without ground (GND) filtering
L1 L2
Fuse Fuse Fuse

L N PE

L3 N PE

LIN

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

LIN

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

ACDC SURGE PROTECTOR Type - PI 7125 Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

mark

mark

mark

mark

GIN GOUT

GIN GOUT N

GIN GOUT N

GIN GOUT

PARALLEL - Single Phase Installation ( for current > 100A per phase )
L
C1
Fuse

PARALLEL - Three Phase Installation ( for current > 100A per phase )
L1 L2 L3
C1 C2 C3
Fuse Fuse Fuse

N PE

C1'

N PE
C1'

C2'

C3'

LIN

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

LIN

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT LIN
MULTI-STAGE

PARALLEL

PARALLEL

L LOUT
MULTI-STAGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

PROTECTION

SURGE

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND

II

IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

ACDC SURGE PROTECTOR Type - PI Blue Series Load Rating: 230VAC @ 100A

Blue

Series

GND II IV,VI

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)
CLASS I+II+III

EIGHT PROTECTION STAGES


1, 3 and 7 Stage: Filter (bi-directional wave tracking); 3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz 2, 4 and 5 Stage: Surge Limiter (L-N) 150kA (8x20s); 22kA (10/350s) 6. Stage: MOSFET Limiter-500A (8x20s)(RT<1ns) 8. Stage: Surge Limiter (N-Gnd) 125kA (8x20s); 20kA (10/350s)

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

FAULT

CORRECT

CORRECT

mark

mark

mark

mark

GIN GOUT

GIN GOUT N

GIN GOUT N

GIN GOUT

acdc-dcac@acdc-dcac.eu

ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia

Phone: 389 2 3216 988; Fax: 389 2 3216 993

. . . ACDC DCAC for Your Safety

I (kA)
100

surge
U(V) +Uc + Umax 2 + Umax/ 2

Iimp

80

Imax
60

Wave 10x350s

40

Wave 8x20s

20

10

100

200

300

400

500

600

700

800

900

1000

t (s)

Voltage Spike Random Noice Destructive Voltage

Uef

Safe Power Supply


10 15 20

t (ms)

50Hz Sinusoidal
-Uc - Umax 2

Waveform Tracking Filter

Destructive Voltage

Blue Series

Red Series

Orange Series

Green Series

Yellow Series

Pink Series

Surge
Protection

ACDC Surge Protector


Single Phase Application Three Phase Signal Line Installation Hard Wire Plug In Connection Series Connection Parallel Connection (Optional) Signal. for Ground Condition Grounding Option for ground Filtering No Ground Contamination Degree of Protection Eight (8) Stages Surge Protector Three (3) Stages Surge Protector Three Stages Signalization Signalization AC Signalization Signal Line Signalization Modularity Options Free Contact Alarm Degree of Enclosures IP54, IP65 Standards
IEC61643-1 Class I+II+III; IEC60939-2

Products Manufacture by ACDC DCAC Multi-Stage Surge Protection Dane Krapcev no.2/1 1000 Skopje, Macedonia Phone: 389 2 3216 988 Fax: 389 2 3216 993 acdc-dcac@acdc-dcac.eu www.acdc-dcac.eu

IEC61643-21

Vous aimerez peut-être aussi