Nominal data
Type Motor Phase Nominal voltage Connection Frequency Type of data definition Valid for approval / standard Speed Power input Current draw Max. back pressure Min. ambient temperature Max. ambient temperature Starting current min-1 W A Pa C C A Hz VAC W6D800-GD01-01 M6D138-LA 3~ 400 50 ml CE 880 1940 3.9 160 -40 60 13 3~ 400 Y 50 ml CE 670 1210 2.23 92 -40 60 4.3

ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations

Data according to ErP directive


Actual Request 2013 Request 2015

Installation category Efficiency category Variable speed drive Specific ratio*


*

A Static No 1.00

Overall efficiency es Efficiency grade N Power input Pe Air flow qv Pressure increase pfs Speed n kW m/h Pa min-1

35.2 40 1.72 17215 124 905

31.2 36

35.2 40

Specific ratio = 1 + pfs / 100 000 Pa

Data established at point of optimum efficiency

Item no. 10178-5-9980 Revision 75933 Release 2012-04-26 Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W6D800-GD01-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Technical features
Mass Size Surface of rotor Material of terminal box Material of blades Material of wall ring Material of guard grille Number of blades Blade angle Direction of air flow Direction of rotation Type of protection Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard Approval 44 kg 800 mm Cast in aluminium PP plastic Aluminium sheet insert, sprayed with PP plastic Sheet steel, pre-galvanised and coated in black plastic (RAL 9005) Steel, coated in black plastic (RAL9005) 5 0 "V" Clockwise, seen on rotor IP 54 "F" F3-1 + 80 C - 40 C Any On rotor and stator sides S1 Ball bearing <= 3.5 mA

Via terminal box Thermal overload protector (TOP) brought out Axial I (if protective earth is connected by customer) EN 60034; EN 61800-5-1; CE VDE

Item no. 10178-5-9980 Revision 75933 Release 2012-04-26 Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W6D800-GD01-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Product drawing

1 2 3

Direction of air flow "V" Tightening torque 1.50.2 Nm Cable diameter: min. 7 mm, max. 14 mm, tightening torque: 20.3 Nm

Item no. 10178-5-9980 Revision 75933 Release 2012-04-26 Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W6D800-GD01-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Connection screen

L2 U2 PE

Delta connection = V1 = blue green green/yellow

Y L3 V2

Star connection = W1 = brown white

L1 W2 TOP

= U1 = black yellow 2 x grey

Item no. 10178-5-9980 Revision 75933 Release 2012-04-26 Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com

W6D800-GD01-01

AC axial fan - HyBlade


sickled blades (S series) with full square nozzle

Charts: Air flow 50 Hz


Druck p f s[Pa]fr Rho=1,2kg/m^3

240 230 220 210 200 190 180 170 160 150 140 130
p f s[Pa]

2.000

4.000

6.000

qv[cfm] 8.000

10.000

12.000

14.000

16.000 0,95 0,9 0,85 0,8 0,75 0,7

Measurement: LU-113998 Measurement: LU-115288 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.

0,65 0,6 0,55 0,5


p fs_E[IN H2O]

120 110 100 90 80 70 60 50 40 30

3 8

0,45 0,4 0,35

7 2 6

0,3 0,25 0,2 0,15 0,1

20 10 0 0 2.000 4.000 6.000 0,05

a] f s[P p

8.000 10.000 12.000 14.000 16.000 18.000 20.000 22.000 24.000 26.000 28.000 qv[m^3/h]

] [Pa fs p

Measured values
Conn. 1 2 3 4 5 6 7 8 Y Y Y Y U V 400 400 400 400 400 400 400 400 f Hz 50 50 50 50 50 50 50 50 n min-1 925 910 900 880 780 740 710 670 Pe W 1380 1581 1720 1940 1000 1079 1129 1210 I A 3.30 3.44 3.60 3.90 1.85 1.98 2.08 2.23 LpAin dB(A) 65 65 66 70 61 60 60 62 LwAin dB(A) 72 72 73 77 68 66 67 70 LwAout dB(A) 72 71 72 76 67 66 66 69 qv m3/h 24110 20850 17990 13450 20430 16980 14290 10250 pfs Pa 0 60 110 160 0 40 69 92

Conn. = Connection U = Supply voltage f = Frequency n = Speed Pe = Power input I = Current draw LpAin = Sound pressure level inlet side LwAin = Sound power level inlet side LwAout = Sound power level outlet side qv = Air flow pfs = Pressure increase

Item no. 10178-5-9980 Revision 75933 Release 2012-04-26 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com