Silver Series 500VA-2KVA

Omecta Solar

SolarTronics Hybrid Inverter - Silver Series 500VA-2KVA


SolarTronics- 500VA (12Volt), builtin MPPT Charge Controller SolarTronics- 1KVA (24Volt), builtin MPPT Charge Controller SolarTronics- 2KVA (48Volt), builtin MPPT Charge Controller

A)

Priority- Solar->Battery->Grid

Block Diagram
PV Array MPPT Charge Controller

PV Connector Box

INVERTER

Main DC Breaker GRID

GRID CHARGER

TO AC LOAD

Batteries

OPERATIONAL SEQUENCE FOR SOLAR OFF-GRID INVERTER


Priority-(solar-battery-grid) (NO CHANGE OVER) When solar energy is sufficient then total o/p load will operate on solar through MPPT & Inverter. Excess solar power will charge batteries When solar energy is weak then inverter is taking DC source from solar & balance from batteries When batteries reach 75% discharge level (25% kept as a buffer) then o/p load is shifted to grid without any changeover time After shifting load to gird the batteries are charged from solar energy and if solar energy is not enough to charge the batteries, then remaining DC power is taken from grid charger. Once the batteries are fully charged then the load is shifted back onto batteries from grid During changeover of load from battery backup to grid supply (i.e 75% battery discharged) and if grid supply is absent then load is shifted to inverter to use buffer battery backup (i.e balance 25%) When grid returns during which inverter is working on buffer battery backup then the load is shifted to grid & batteries are charging through solar or grid as per logic explained above

Technical Specification of SolarTronics Hybrid Inverter - Silver Series 500VA-2KVA


SolarTronics- Silver series Inverter-500VA-2KVA
Rating
Nominal Input Input Cutt-Off Computer Mode Normal Mode Input Connection Output Output Voltage Output Power Output Frequency Output Connection Efficiency Mains Mode Transfer Time Surge Load Battery Voltage Typical Low Battery Alarm Voltage Typical Shut Down Charging Current (Difference in current > 2) Protections 1000W Resistive Load 12 VDC 11V 10.8V High 14-18A Lightning Output Short Battery Wire 370 x 295 x 95 mm 5.7 KGS Battery Over Voltage Over Load Battery Wire

500 VA INPUT

1KVA
230V,50HZ

2KVA

INPUT VOLTAGE LOWER CUT OFF INPUT VOLTAGE HIGHER CUT OFF 165-185V AC 270-280V AC 110-130V AC 270-280V AC 3 PIN PLUG(15A)

OUTPUT
500VA / 500W Inverter Mode 230V+/-10% 1000VA / 1000W 49-51Hz 3-PIN OUTLET(15A) 85% Same As Input Less than 15 milli Second 2000W Resistive Load 24VDC 22V 21.6V 4000W Resistive Load 48 VDC 44V 43.2V Low 8-13A Battery Under Voltage Phase Reversal Main Charger 2000VA/2000W

BATTERY-300AH RECOMMENDED

Dimensions
Dimensions Weight MPPT Solar Charger Battery Charging Current Maximum Solar Peak Charger Max. Solar Open Circuit Voltage Minimum Solar Open Circuit Voltage Humidity Operating 405 x 300 x 130 mm 7.5 KGS

MPPT Solar Charger


Intelligent Maximum Power Point Tracking Technology 40 AMP 1000W 2000 W 95% 85 Volt 36 Volt 120 Volt 72 Volt

500W 85 Volt 36 Volt

Environment
0-90% RH 0-45 Degree Celsius