Vous êtes sur la page 1sur 6

4


b Q


F h q C D r @ v p w

'

"

"

&

n l

r v

JP2
v p q r v y o

JP3 JP4

JP1
p q n

"

"

p z q u

| m

y l

p q r v

v y

} ~  i

4. CT series cable drawing


CT series cable (COTEK Part no.47-0124-0001)
Mating Housing / Contact
JST JST PHDR-24VS SPHD-002T-P0.5 or equivalent or equivalent
24 23 24 23

P1

P2

200

RS232

CT parallel cable (For CT-551 Only) (COTEK Part no. 47-0106-0003)


12.40.3 6.50.2 3.10.2 (1) INSULATION JACKET 12.40.3 6 9.60.2 1 (2) 30cm (2) 1 6.50.2 CONDUCTOR 14.60.3

3.10.2

A
6 9.60.2

14.60.3

6P4C

WARNING! DO NOT use standard telephone cable.

CT-204 to CT-204 series cable (Optional) (COTEK Part no. 47-0103-0028)

300mm 5

5. Accessories
Accessories MODEL CT-201 CT-204 CT-251 CT-551 User Guide CT series cable 1 1 1 1 1 4 1 1 CT parallel cable ------1 EC350R-05P CT-204 to CT-204 connector series cable 1 --1 1 --Optional -----

6. Pin assignment DB-9F RS232 (only for CT-201/204/251)


1 2 3 4 5 6 7 8 9 NC RxD TxD NC GND NC NC NC NC
8: 7: 6: DSR 4: DTR 5: VCC 4: TXD 3: RXD 2: GND SK-XXX INVERTER 6P PHONE JACK REMOTE INTERF ACE CABLE : VCC 3: TXD 2: RXD 5: GND

9P FEMALE D-SUB TO PC RS-232

RJ-11 6P4C RS485 (only for CT-251/551)


1 2 3 4 5 6 NC GND DATA + DATA +5V NC
1
RS485

RJ-11 6P4C

ECH350V-05P DINKLE (only for CT-201/251/551)


1 2 3 4 5 GND AUX PAR VS VS +

B-XH-A 180C (only for CT-204)


1 2 3 GND RxD TxD
1 2 3

Control Pin connections: JST S24B-PHDSS or equivalent


Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment 6 16 NC. GND SDA ACI VS1 21 11 AUX 7 NC. GND PAR VO2 22 12 17 AUX 3 23 13 8 18 VSET GND EN+ VS+ AUX 9 19 GND VCI 4 POK VO+ 24 14 5 10 15 20 SCL ENGND GND

7. CT Series Quick Feature Guide


Function Parallel / Remote sense MODEL CT-201 CT-204 CT-251 CT-551 To Host RS-232(DB-9F) RS-232(DB-9F) RS-232(DB-9F)
---

Power Connection 1 Unit 4 Units 1 Unit 1 Unit

RS485 Expansion

RS232 Expansion

8. Application Notes MODEL: CT-201 Programmable Power Supply


4 2 3
5

DC OUTPUT

CN2

+
Load

7
2 3
1

MAX. 200mm CT series cable

MODEL: CT-204 Series Control 4 EUT. Programmable Power Supply


4
5

2 3

2 3

2 3

CN2

CN2

CN2

MAX. 200mm CT series cable MAX. 200mm CT series cable

MAX. 200mm CT series cable

CN4

23

JP4

CN3

23

JP3

CN2

23

JP2

CN1

23

JP1

CN5

CN7
1

PC
RS232

CN6

MAX. 10M

CT-204

CN1

23

5 4 3 2 1 CN2
1

PC
MAX. 10M

CN3
6 1

Programmable Power Supply


4
5

RS232

CT-201

Programmable Power Supply


4
5

Programmable Power Supply


4
5

DC OUTPUT

DC OUTPUT

DC OUTPUT

DC OUTPUT

CN2

6
7

6
7

6
7

6
7

+
MAX. 200mm CT series cable

Load
Total Output MAX < 500VDC

MODEL: CT-204 Series Control 8 EUT. Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

DC OUTPUT

CN2

CN2

CN2

MAX. 200mm CT series cable

MAX. 200mm CT series cable

MAX. 200mm CT series cable

CN4

23

JP4

CN3

23

JP3

CN2

23

JP2

CN1

23

JP1

CN5

CN7
1

CN6

CT-204
CT-204 to CT-204 series cable

RS232

Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

Programmable Power Supply


4 2 3
5

DC OUTPUT

CN2

CN2

CN2

MAX. 200mm CT series cable MAX. 200mm CT series cable

MAX. 200mm CT series cable

CN4

23

JP4

CN3

23

JP3

CN2

23

JP2

CN1

23

JP1

CN5

CN7
1

PC
RS232

CN6

CT-204

MAX. 10M

DC OUTPUT

DC OUTPUT

0 6 7

0 6 7

DC OUTPUT

DC OUTPUT

DC OUTPUT

CN2

6 7 0 6 7 0

6 7

6 7

6 7

+
MAX. 200mm CT series cable

Load
Total Output MAX < 500VDC

DC OUTPUT

CN2

6 7

MAX. 200mm CT series cable

MODEL: CT-251 / 551 Parallel Control with Remote Sensing


Programmable Power Supply
4 2 3

MAX.8 EUT

Programmable Power Supply


4 2 3

Programmable Power Supply


4 2 3

Programmable Power Supply


4 2 3

DC OUTPUT

CN2

CN2

CN2

MAX. 200mm CT series cable

MAX. 200mm CT series cable

MAX. 200mm CT series cable

23

23

23

*Last control board J1 need short


1

CT-551

RS485

CT-551 RS485

RS485

CT-551 RS485
MAX. 200M CT parallel cable

RS485

CT-251 RS485

RS232

MAX. 200M CT parallel cable

Before using RS232/485 to control COTEK programmable SMPS (excl. AK Series), make sure to read the following notes: 1. Make sure the voltage and current setting has been correctly delivered to EUT before setting the command (Power <type>) to turn on / off the power supply. If OVP, or OLP LED signal has been activated due to incorrect operation, enter command POWER <type> will allow you to operate the EUT and setting command. 2. Every RS232/485 command character must be entered within 400ms, the ending point is judged by CR LF (0D0A), program will disregard the command if the command entering time exceeds 400ms per character. 3. After shut-down of the power of EUT, command setting will return to default, local mode. 4. After power on the EUT with command execution complete, EUT will switch to remote mode with orange LED signal status. For detail LED signal info, please refer to the EUT datasheet. 5. Please refer to the CT-xxx user manual (Page 02) for the cable spec. connect in between the CT-xxx controller board and EUT. Make sure to connect the cable as instructed on the user manual to avoid CT-xxx damage. 6. CT-xxx boards could support max. 8 units serial or parallel control function (ADDS 0-7). Before controlling the EUT, make sure the address is not in conflict with each other. 7. When controlling multiple EUTs, make sure to query the Address (ADDS x) first before entering command to avoid EUT retrieving the incorrect value. If only single EUT, there is no need to query ADDS before entering command.

No. 33, Rong Hsin Rd., Pa Teh City, Tao Yuan County, Taiwan Phone : 886-3-3661581 FAX : 886-3-3676029

http : // www.cotek.com.tw
2013.04 A0

DC OUTPUT

DC OUTPUT

DC OUTPUT

CN2

5
6

5
6

5
6

5
6

7
0

+
Load
MAX. 200mm CT series cable

CN1

CN1

CN1

CN1

23

2
6

CN2

CN2

CN2

CN2
J1
1

J1

J1

CN3

CN3

CN3

CN4

CN4

CN4

CN4

CN3

J1

PC
MAX. 10M