Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement cette rgle est illicite et expose son auteur au versement de dommages et intrts.
Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Sin nuestra expresa autorizacin, queda terminantemente prohibida la reproduccin total o parcial de este documento, as como su uso indebido y/o su exhibicin o comunicacin a terceros. De los infractores se exigir el correspondiente resarcimiento de daos y perjuicios.
DISTRIBUTION UNIT
Content
Page
1 1.1 1.2 1.2.1 1.2.2 1.3 2 2.1 2.1.1 2.2 2.2.1 2.2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6 3 4 4.1 4.1.1 4.1.2 4.2 5 6 Drawings: DU compact Distribution Unit
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard application of the Distribution compact . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information about LEDs, push buttons, switches and plugs of the I/O PCB . . . . Installation of the Distribution Unit compact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General remarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General remarks about establishing an earth connection . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS422--Interface or NMEA Interface of Heading Receiver . . . . . . . . . . . . . . . . . . . Installation of the options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections of the terminal board L1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections of the statussignals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections of repeaters with supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections of repeaters without supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections for Step--signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connections for course printer an RoT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching ON of the Distribution Unit compact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustment of the output channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection of the output channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustment of serial output data (NMEA 1 / NMEA 2) . . . . . . . . . . . . . . . . . . . . . . . Adjustment of the RoT--output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching OFF the Distribution Unit compact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance and repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 3 3 3 4 10 10 13 14 15 16 16 16 17 17 18 18 19 20 21 21 22 23 43 25 25
138--126.HP005 138--126.HP008
3815.DOC010002
Safety regulations
Caution: Installation, maintenance and repair work must be carried out only by properly trained and qualified staff with a good knowledge of national equipment safety regulations.
3815.DOC010002
II
DISTRIBUTION UNIT
General The Distribution Unit compact 138--126 consist of an aluminium casting in which a printed circuit board is integrated: -- I/O PCB. At the bottom of the casting there are 27 cable inlets for connecting repeaters, gyros and other heading receivers and sensors. The task of this Distribution Unit compact is: -- System monitoring by alarm-- and status messages. -- Distribution of corrected heading information to all connected heading receivers. -- Power supply of all connected heading receivers (8 heading receivers and 3 step--outputs supplied with power and of the connected heading sensor (compass).
There are operating procedures during the operation of the Distribution Unit compact. Only the setting to work--procedure needs some settings performed by DIP--Switches at the I/O PCB.
Options are: AC/DC--Converter to generate the supply voltage for the Distribution Unit compact.
3815.DOC010002
1.1
3815.DOC010002
Option:
138-126
2
18 -- 36 V DC Distribution Unit compact 138--126 24VDC Input: -- Course bus
115--230V AC 50/60Hz
or
18 -- 36 V DC
Outputs: -- 12x outputs, separate adjustable: either Course bus, NMEA 1 or NMEA 2 -- Statussignals: System failure Compass failure Compass avaailable -- 1x ROT or heading analogue -- 1x Course printer -- 3x Step
DISTRIBUTION UNIT
1.2 1.2.1
Technical Data Mechanical Data Dimensions, weight and internal protection see Dimensional Drawing DU compact 138--126.HP005
1.2.2
Electrical Data Supply voltage: Power consumption: 18VDC.......36VDC 6W at 24V DC Supply voltage (without connected receivers and compass)
Inputs: Course bus Outputs: -- 12 outputs (electrical RS422), 8 channels with supply voltage for heading receivers each channel separate adjustable heading serial (Course bus) NMEA1 (Heading and/or RoT, different transmission rates) NMEA2 (Heading and RoT, different transmission rates -- RoT analog or heading analog (+/-- 10V) -- Course printer interface RS232C -- 3 STEP--Signals 1/6/Step (with voltage supply 35V DC) -- Statussignals System failure Compass failure Compass available
3815.DOC010002
1.3
Information about LEDs, push buttons, switches and plugs of the I/O PCB 6 7 8 9 10 11 12 13 14
see Figure 3
5 4 3
15
see Figure 7
2 Figure 2: No. Figure 2/3 Figure 2/4 Figure 2/5 Figure 2/6
see Figure 4
see Figure 5
see Figure 6
I/O PCB (138--118.101.E10) Designation Plug B1 LED H38 Plug B10 Plug B4 not used 35V DC for the Step function, lights up if this voltage is present Supply voltage 24V DC for the I/O PCB Connector to flash Lights up if, supply voltages + 5V DC and +/-- 15V DC are present Reset CPU, used during flashing Processor clock, blinks green not used, future purpose Lights up red, if the 35V DC for the Step function is internal switched off. Remark Fr magnetic sonde application
Figure 2/7,8, LEDs 9,10,11 H42,H40,H41,H44,H43 Figure 2/12 Figure 2/13 Figure 2/14 Figure 2/15 Push button B 40 LED H1 Switch B36 LED H50
3815.DOC010002
DISTRIBUTION UNIT
B 39
Figure 3:
No.
Designation
Remark In combination with switch B39. Blinks, if adjustments are possible. Switch direction of switch B39 to the right. Lights up in operation mode, Switch direction of switch B39 to the left. (Switch direction to the DIP Switch)
Figure 3/2 Switch B42 Figure 3/3 Push button B38 Figure 3/4 Switch B39
To adjust the dataformats of the selected output channels. Push button to select the output channels 1 to 12. Only of switch B39 is switched to the right. To switch the operation modes switch direction to the right (away from the DIP--switch) = mode to adjust switch direction to the left (to the DIP--switch) = operating mode
3815.DOC010002
Figure 4:
No.
Designation
Remark To connect statussignal Gyro available. LED lights up, if Compass available. To connect statussignal Gyro failure. LED lights up, if Compass fails. To connect statussignal System failure. LED lights up, if a voltage at the I/O PCB has failed.
Figure 4/1 Plug B13 Figure 4/2 LED H4 Figure 4/3 Plug B12 Figure 4/4 LED H3 Figure 4/5 Plug B11 Figure 4/6 LED H2 Plug Plug Plug Plug Plug Plug Plug Plug Plug B22/LED H13 B21/LED H12 B20/LED H11 B19/LED H10 B18/LED H9 B17/LED H8 B16/LED H7 B15/LED H6 B14/LED H5
not used
3815.DOC010002
DISTRIBUTION UNIT
8 7 6 5 4 3 2 1
10
11
12 13
Figure 5:
No. Figure 5/1 Figure 5/2 Figure 5/3 Figure 5/4 Figure 5/5 Figure 5/6 Figure 5/7 Figure 5/8, 9 and 10
Designation Plug B35 Plug B9 Fuse E11 Plug B8 Fuse E 10 Plug B7 Fuse E9 LED H47, 48 and 49
Remark To connect Course bus to the I/O PCB. To connect a Step--output. (0,25A, slow) to protect 35V DC of the Step--output at plug B9. To connect a Step--output. (0,25A, slow) to protect 35V DC of the Step--output at plug B8. To connect a Step--output. (0,25A, slow) to protect 35V DC of the Step--output at plug B7. Image of the Step--outputs. To connect Course printer. To connect RoT (analog). 24V DC Connection to supply the receivers connected at the output channels 1 to 8.
3815.DOC010002
12 11 10 9 (Channel 9)(Channel 10)(Channel 11) (Channel12) Figure 6: No. Figure 6/1 I/O PCB (138--118.101.E10) Designation Plug B 27 Fuse E5 LED 26 (red) LED 27 (green) LED 28 (blue) Remark Output channel 5 with supply voltage to connect a repeater. Connection, protection and monitoring of the adjusted data format. LED red = Course bus LED green = NMEA 1 LED blue = NMEA 2
Figure 6/2 Figure 6/3 Figure 6/4 Figure 6/5 Figure 6/6 Figure 6/7 Figure 6/8 Figure 6/9
B 28, E 6, H 29, H 30, H 31 Output channel 6 B 29, E 7, H 32, H 33, H 34 Output channel 7 B 30, E 8, H 35, H 36, H 37 Output channel 8 B 26, E 4, H 23, H 24, H25 B 25, E 3, H 20, H 21, H22 Output channel 4 Output channel 3
B 24, E 2, H 17, H 18, H 19 Output channel 2 B 23, E 1, H 14, H 15, H 16 Output channel 1 Plug B 34 LED H 57 (red) LED H 56 (green) LED H 55 (blue) Output channel 12 to connect heading receivers. Connection and monitoring of the adjusted data format. LED red = Course bus LED green = NMEA 1 LED blue = NMEA 2 Output channel 11 Output channel 10 Output channel 9 8
Figure 6/10 B 33, H 54, H 55, H 56 Figure 6/11 B 32, H 51, H 52, H 53 Figure 6/12 B 31, H 39, H 45, H 46
3815.DOC010002
DISTRIBUTION UNIT
Figure 7:
Terminal board L1
No.
Designation
Remark Protection of the 24V DC supply voltage for: -- Distribution Unit compact -- Compass -- Repeater with supplied voltage -- Step outputs Terminals to connect 24V DC supply voltage for the Distribution Unit compact and the connected compass. Terminals to connect the course bus from the compass.
3815.DOC010002
2 2.1
Caution When establishing cable connections ensure that the cables are disconnected from the power supply. It is essential to ensure that all cables are disconnected from the power supply, if necessary measure the voltage beforehand and/or disconnect the relevant distributor.
In order to ensure that the system operates correctly, it is essential that you follow the procedures described below for establishing cable connections. For information to the respective cable diameter see Wiring diagram138--126.HP008. -- Strip approx. 180mm of the cable (depending on the distance between cable inlet and terminal or plug). Make sure you do not damage the shielding layer. -- Strip off the shielding to a remainder of approximately 15mm.
approx. 15mm
approx. 180mm
Figure 8 How to strip the connection cable
-- Screw the cable gland out from the distribution box and push the screw connection components over the cable. It is absolutely essential that the sequence (as shown in Figure 9) is adhered to. -- Check the cone and counterpart on the earthing insert for corrosion and if necessary remove corrosion using an appropriate process (emery board).
3815.DOC010002
10
DISTRIBUTION UNIT
-- Push the counterpart of the earthing insert as far as the end of the cable shield. -- Push the earthing insert cone below the shielding against the counterpart. Observe a shared evenly distribution of the shielding via the cone (see Figure 9).
Wall and DIN socket Earthing insert -- Cone -- Counterpart Seal + Strain relief Shielding
Figure 9
-- Insert the earthing insert, the seal with and the washer into the cable gland, place the counter nut on top and hand-tighten. -- Strip the cable cores to a length of approx. 1.5cm, twist slightly and clamp on the cable end sleeves. Connect the cable strands in the junction box as shown in the table below. Hand-tighten the terminal screws concerned -- Check the connection is firm by pulling lightly.
11
3815.DOC010002
Attach the angle with cross slotted screws below the respective cable inlet at the housing. (angle and screws are part of the installation kit). Strip off the cable according to section 2.1.
The screen must be led for appr. 15mm through the cable inlet (as shown).
Jam the cable (screen area) with the screw-clamp at the angle and fix it with the knurled head screw.
3815.DOC010002
12
DISTRIBUTION UNIT
2.1.1
General information about establishing an earth connection In order to comply with the stringent EMC requirements, please abide by the information given below regarding cable connections. Use the cable types specified.
It is essential to ensure that these connections have a common reference to the ships earth. Any additional components (options) must also be connected to the common earth!
Figure 10:
All earth connections must be made as shown in Figure 10. The earthing cable attached to the cable bracket must possess a cross-section of minimum 1.5 mm2. The cable bracket should be mounted between two toothed discs. Earth connections must be free of corrosion and well fastened.
13
3815.DOC010002
2.2
Installation The distribution unit has to be mounted according to the dimensional drawing 138--126.HP005. The front cover should be removable. Please note the comment depending the internal protection at the dimensional drawing.
3815.DOC010002
14
DISTRIBUTION UNIT
2.2.1
RS422-Interface or NMEA Interface of Heading Receiver Conclusion for the connection of NON RAYTHEON Anschtz products to the Distribution Unit Compact: If the NMEA input interface or the coursebus input interface contains a signal common / signal ground connection, then this connection has to be connected to signal common / signal ground connection of the Distribition Unit Compact (see principle scematic below).
NMEA
1 2 3 4 Heading 5 6 Heading receiver Supply voltage Protection circuit
RS422
1 2 3 4
Heading
15
3815.DOC010002
2.2.2
Installation of the options For installation of the option AC/DC--Converter, see service manual of the compass STD 22.
2.3
Connections For additional information to the connectors, see Wiring diagram 138--126.HP008.
2.3.1
E1 1 2 3 4 5 6 7 8 9
1 E1
2 3 4
5 6 7 8 9
24 V DC to the compass
Figure 11:
Terminal board L1
Assignment
3815.DOC010002
16
DISTRIBUTION UNIT
2.3.2
Connections of statussignals
Figure 12:
1 2 3 Connection of statussignals
Connection 1 2 3
Assignment
B12
--Gyro failure
1 2 3
B11
-- Gyro available
1 2 3
2.3.3
1 Figure 13:
4 5
Plug B 23 (Channel 1), B 24 (Channel 2), B 25 (Channel (Ch l 3), 3) B 26 (Channel (Ch l 4), 4) B 27 (Channel 5), B 28 (Channel 6), B 29 (Channel 7), B 30 (Channel 8)
Connection 1 2 3 4 5 6 TX + TX -GND 0V DC
Assignment + 24V DC
17
3815.DOC010002
2.3.4
Figure 14:
Plug B31 (Channel 9), B32 (Channel 10), B33 (Ch (Channel l 11), 11) B34 (Channel (Ch l 12)
Connection 1 2 3 TX + TX -GND
Assignment
2.3.5
1 Figure 15:
2 3
Plug B 7, B 8, B 9
Connection 1 2 3 4 5 + 35V DC 0V DC S1 S2 S3
Assignment
3815.DOC010002
18
DISTRIBUTION UNIT
2.3.6
1 Figure 16:
Plug B 5 (RoT)
Assignment
B 6 (Course printer -- RS232C) ( i t di (printed is only l heading h di and d an internal time time code)
1 2 3
19
3815.DOC010002
Switching ON of the Distribution Unit compact After switching ON the mains supply the Distribution Unit compact is switched ON. A separate switching ON of the Distribution Unit compact is not possible. Together with a switching ON of the mains supply to the Distribution Unit compact the compass as well as the connected heading receivers are supplied with operating voltage too.
3815.DOC010002
20
DISTRIBUTION UNIT
4 4.1
Configuration Adjustment of the output channels The adjustment of the output channels is performed by operating the DIP--switch B42, the switch B39 and both push buttons B37 and B38.
B39
DIP--switch B42
OPEN
1 2 3 4 5 6 7 8
RoT NMEA1 NMEA2
Figure 17:
Each of the 12 output channels can be adjusted in consideration of the data content: -- Course bus -- NMEA 1 -- NMEA 2
21
3815.DOC010002
4.1.1
Selection of the output channels By pushing the switch B39 (Figure 17/4) to the right,switching direction away from the DIP--switch B42 (Figure 17/2), the configuration mode is activated. The LED H60 (Figure 17/1) blinks. With every operation of push button B38 (Figure 17/3) another output channel is selected. At the selected channel blinks one of the LEDs (red, green or blue). With every operation of the push button B37 (Figure 17/5) the data content of the selected output channel is changed (course bus -- NMEA 1 -- NMEA 2). If the red LED blinks then course bus is adjusted to the selected output channel, for NMEA 1 the green LED blinks and for NMEA 2 the blue LED blinks. By pushing the switch B39 to the left, switching direction to the DIP--switch all adjustments are stored and the LED H60 lights up constantly.
3815.DOC010002
22
DISTRIBUTION UNIT
4.1.2
Adjustment of serial output data (NMEA 1 / NMEA 2) This adjustments have to be performed exclusively by the DIP--switch. These adjustment have to be permanent. Changes of these adjustments are achieved at once during the operational mode. Below mentioned adjustments are possible:
DIP--switch Data format NMEA 1 (green LED) HEHDT+HEROT HEHDT 4800 Bd 4800 Bd 9600 Bd 38,4 kBd (1Hz) (10Hz) (10Hz) (50Hz)
X X X X X X
X X X X X X
0 1 n n n n
X X 0 1 0 1
X X 0 0 1 1
X X X X X X
X X X X X X
X X X X X X
NMEA 2 (blue LED) HEHDT+HEROT 4800 Bd 4800 Bd 9600 Bd 38,4 kBd (1Hz) (10Hz) (10Hz) (50Hz) X X X X X X X X X X X X X X X X X X X X X X X X X 0 n n n n X 0 0 1 1 X 0 1 0 1
X = Adjustment without importance n = Adjustment depends to another row in the table 1 = DIP--switch position up (1) 0 = DIP--switch position down (0)
DIP--switch B42
1 1 2 3 4 5 6 7 8
Never switch DIP--switches 6, 7 and 8 at the same time into the upper position (a development function only).
23
3815.DOC010002
4.2
Adjustment of the RoT-output The turn rate (analog) at plug B5 is adjustable as follows: DIP--switch Data format Heading output analog +/-- 10V Turn rate 30 /Min. Turn rate 100 /Min. Turn rate 300 /Min. 1 0 1 0 1 2 0 0 1 1 3 X X X X 4 X X X X 5 X X X X 6 X X X X 7 X X X X 8 X X X X
X = Adjustment without importance 1 = DIP--switch position up (1) 0 = DIP--switch position down (0)
DIP--Schalter B42
1 1 2 3 4 5 6 7 8
3815.DOC010002
24
DISTRIBUTION UNIT
Switching OFF the Distribution Unit compact By switching OFF the mains supply to the Distribution Unit compact, the connected compass, all connected heading receivers which are supplied via the Distribution Unit compact and the Distribution Unit compact itself are switched OFF.
Maintenance and repair The Distribution Unit compact is maintenance free. A repair is only possible by a replacement of fuses otherwise the Distribution Unit compact has to be replaced complete.
25
3815.DOC010002