AHMEDABAD MUNICIPAL CORPORATION MAHANAGAR SEWA SADAN WATER OPERATION (E & M ) DEPARTMENT TENDER NOTICE Sealed super scribed

tenders are invited from interested bidders for below mentioned items Sr. No. 1 Tender Fee Rs. EMD Rs.

Name of work Construction, drilling & developing of 350 x 250 mm dia 300 mtr. deep tube well along with SITC of pumping machineries with labour and materials for JnNURM project at following EWS Quarters. (1) East Zone Odhav Vepari Mahamandal, Plot No - 51. (2) Vatva T.P. no- 88, Plot No 51/1 + 51/2 + 53/1. (3) Odhav Bahiyal Ground T.P. no- 3, Plot No 86/P. (4) Shahvadi EWS Quarter T.P. no- 94, Plot No 2/1. ------------------- Do as above -----------------------------(1) East Zone Ajit Mill T.P. no - 10, Plot No 83. (2) Raypur Mill T.P. no- 11,Bapunagar Plot No43 + 47. (3) Sarangpur Kesari Hind Mill T.P. no- 18, Plot No 14. (4) Vadaj Shrinath EWS Quarter T.P.no- 28, Plot No 83/8.

Qty.

4 Nos.

2400/-

92000/-

4 Nos.

2400/-

92000/-

Annual rate contract for supply of different type of Lot spare parts for SIMENS make switch, starters and Rs.5.00 electrical equipments. lacs

900/-

5000/-

Details may be downloaded from AMC web site www.egovamc.com and should be submitted on or before 2.00 pm Dt.- 27/07/10 to the The Tender officer, Central Record Office, Sardar Patel Bhavan, A.M.C., Ahmedabad. Published by water operation (E & M) Dept . " RECHARGE GROUND WATER SOURCES"

AHMEDABAD MUNICIPAL CORPORATION


Water Operation ( E & M ) Department. Conditions of Tender Tender should be sent Last date of Submission of Tender:- 27/07/2010 By Registered A.D. Submission of Time:-up to 2.00 P.M. Speed Post / Hand delivery Date of Opening of Technical Bid : 27/07/2010 Tender Fee Rs 2400/Time of Opening of Technical Bid : 4.00 P.M. Tender for: TENDER FOR CONSTRUCTION, DRILLING & DEVELOPING OF 350 x 250 MM DIA. 300 MTR. DEEP TUBEWELL ALONG WITH SITC OF PUMPING MACHINARIES WITH LABOUR AND MATERIALS. Quantity Site :: Four bore wells.

(1) East Zone Odhav Vepari Mahamandal, Plot No - 51. (2) Vatva T.P. no- 88, Plot No 51/1 + 51/2 + 53/1. (3) Odhav Bahiyal Ground T.P. no- 3, Plot No 86/P. (4) Shahvadi EWS Quarter T.P. no- 94, Plot No 2/1.

1.

2.

3.

4. 5. 6.

7.

8.

9.

10. 11.

A demand draft of Rs 2400/-for Tender fee in favour of Municipal Commissioner should be attached with the Tender and sealed Tender should be addressed to THE TENDER OFFICER, Central Record Office, Municipal Corporation, Sardar Patel Bhavan, Danapith, Ahmedbad380001 should be sent so as to reach him before last date and time. Without tender fee tender will not be considered. EMD of Rs. 92,000/- in the form of Cash/local MICR cheque / pay order / DD / Bank Guarantee drawn on nationalized bank in favour of Municipal Commissioner, Ahmedabad should be attached with the tender. Without EMD tender will not be considered .Cash receipt must be attached with the tender. Successful tenderer shall have to deposit 5% of the tender amount as security of bank guarantee of nationalized bank and shall have to sign a contract with Municipal Corporation as per rules within 15 days after receipt of order. Sales tax, VAT/TIN/PAN registration no. should be mentioned in tender as well as in the bill. Tenderer must be manufacturer of the bore well. Without these tender will not be considered. Material supplied under order shall be new and of first quality according to the specifications and sha ll be free from defects (Including concealed fault, deficiency in design, material and workmanship.) Guarantee: 12 months from the date of commissioning and 18 months from the date of supply for all the electrical and mechanical equipments. Materials replaced / repaired under guarantee / warrantee period shall have further warranty for a period of 12 months from the date of repair / replacement. Prices should be F.O.R. store / site delivery basis including excise duty, sales tax, vat tax, any applicable tax, insurance, delivery charges, unloading charges etc. We do not possess C or D sales tax form. Prices must be firm inclusive of any future taxes imposed in place of octroi, service tax or vat or any other taxes which ever applicable. Our standard payment term is 45 working days after getting 100% supply (as per cl-20). No advance payment or Performa invoice payment or bank through payment will be considered, even if any discount is offered for the same. This standard payment terms is applicable only when the tenderer fulfills above condition No. 3. If any reason payment is not received within 45 days than tenderer is not eligible to claim / demand any compensation for loss of interest or there of. Tenderer must clearly mention make & the materials catalogue no if any, name and full address of the manufacturer and complete details as asked by A.M.C. Tenderer must give validity of tender for minimum 120 days from the date of price bid opened. 2

12.

13. 14. 15.

16. 17. 18. 19. 20.

21. 22. 23. 24. 25. 26.

27 28 29

Municipal Commissioner reserves the right (i) to change, alter or to waive any technical or commercial terms, conditions and qualification (ii) to reject all the tenders or the lowest or any other tender in part or full without assigning any reason whatsoever (iii) for making changes / relaxation in eligibility criteria at any time (iv) to split the tender and award to more than one tenderer in the interest of public. The tenderers shall have no cause of action or claim against the corporation or its officers, employees, successors or assignee for rejection of his tender. Conditions of tender issued by Municipal Corporation must be duly signed and should be attached with the tender. The successful bidder shall have to offer inspection of material before supply if required by AMC. Tenderer shall have to arrange and bear all the cost of transportation, lodging, boarding and cost for inspection of material if required by AMC. We will depute our representative for the inspection. Tenderer shall have to submit two hard copies (one original + one duplicate)of the tender. Tenderer shall have to mention on the cover. (A)Water Operation (E & M) (B) Tender for (C) Opening date (D) Name of tenderer. Xerox copy of the orders executed for similar items and their performance shall be attached. Conditional tender will not be accepted. Failing the delivery schedule , penalty at the rate of 1% per week with maximum ceiling of 10 % will be charged for not completion of the work in prescribed time limit.. If the work is not completed during this penalty period, then contract will be terminated, security deposit will be forfeited and party will be black listed. Bidder shall have to furnish name of bank, name of branch with address, A/c No., Type of Account, MICR No and IFSE code no. of Bank for refund of EMD on separate letter pad page. The evaluation will be done only on the basis of information submitted with the tender. Information will not be called for by A.M.C. Fresh details if required will have to be submitted. The bidders shall have to furnish their technical & financial details with the tender. If required, Original Certificate / Documents have to be produced by the tenderer at the time of evaluation of tender. Even though the bidder meets the above qualifying criteria, he shall be disqualified if he has made misleading or false representation in the forms, statements and attachments submitted in proof of the qualification requirements and / or record of p oor performance such as abandoning the works, not properly completing the contract, in ordinate delays in completion, litigation history or financial failures etc. The amount quoted against the Total amount column shall be considered final for lowest bidder evaluation. The total amount must be written in figures and words. Tenderer has to check the AMC website for Addendum if any before 48 hours of tender submission date & time. Tenderer who quote tender without attaching tender or the addendum will be rejected. Prices should be quoted in our separate Price Bid format and inclusive of all taxes. At the submission-date and time, tenderer who quote the tender without attaching the tender or the Addendum will be rejected. I/We are fully agree to all the terms, conditions and specifications

Tenderers signature and stamp

Add.C.E. (W.O.E.&M.)

SECTION-I
(A) Eligibility Criteria and Different Parameters for Technical Bid Qualification (a) Post Qualification: 1. The bidder must be manufacturer of the bore well. 2. Tenderer should have carried out successfully complete SITC work of 16"/14"/12"/10 x 10" dia . minimum 800 ft depth of at least five nos. of bores with well screen strainers w ithin last three years. These five bores must be constructed in Municipal Corporation, GWRDC, GWSSB, Power generating company, GEB, Railway, ONGC, similar government and semi government institutes. 3. Tenderer should furnish the self attested copy of work orders for the works shown in Aa/2 and a copy of certificates for satisfactory construction of bores from the same Institution. 4. The determination will take in to account the Bidders financial, technical and production capabilities necessary to perform the contract. It will be based upon the examination of the documentary evidence of the Bidders qualifications submitted by the Bidder. 5. Tenderer must possess annual average turnover of Rs.30 lacs during las t two years. 6. It will be the tenderers responsibility to deposit service tax in the service tax department. 7. Tenderer must have own Drilling rig with present R.T.O. Registration. (b) Parameters for Technical Qualifications Sr. No. 1. 2. 3. 4. AMC Requirements Tender Fee Rs. 2400/E.M.D. Rs.92,000/- DD/ Pay order/ MICR cheque/ bank guarantee The bidder must be manufacturer of bore well Tenderer must have experience of successfully work of 16"/14"/12" 10 X 10" dia .x 800ft. depth of at least five nos. of bore wells with well screen strainers within last three years. Annual average turnover of Rs. 30 lacs for the last two years. Own Drilling rig with latest R.T.O. Registration. (R.T.O Regi. No.) Tenderer Data

5. 6.

Tender ers signature and stamp & Date:

( B ) SCOPE OF CONTRACTOR
1.0 Tenderer shall have to Construct, drilling & developing of Tube-well with Supply, Delivery at Site, Installation of pipes, Strainer pipes and Commissioning of deep bore well with labour and materials with site difficulties and discomfort ness at bore well site. This Specification Covers construction, drilling, electro logging, successfully installing housing, casing & strainer pipes, gravel packing, air compressor, and sub. Pump development of tubewell for deep bore in the city of Ahmedabad. Technical Specification and the construction of bore, details of labour work, pipes, strainer pipes and miscellaneous items to be supplied are enclosed. The technical information and price schedule to be furnished by the bidders is covered in schedule I & II. The equipments and the works shall confirm in all respects high standard of engineering. The tenderer have to arrange Photographs of work at different stages of progress as per the instruction of site engineer in charge .

2.0

3.0

4.0 5.0

6.0 Comprehensive repairing and maintenance work of sub pump set, Ele ct. panel, Starter and chlorine dozing machine during guarantee period- The bidder should complete any electrical or mechanical fault of bore well within six hours from the time of complaint received on the same day. Fault cleared is to be informed to the engineer in charge. Incase pump-motor set is failed, the same is to be rep a ired within 24 hours including lifting & lowering works. Otherwise penalty of Rs.1000 per day will be deducted from the remaining bill. Incase of fault received for maintenance of chlorine dozing machine is to be attended within six hours and if same machine is not repairable it should be replaced by another machine on the same day . If bidder fails to complete the work in prescribed time limit, a penalty of Rs.200/-per day will be recovered from the remaining bill.

Tenderers signature and stamp & Dat e:

(A)
1. 1.1

SECTION II INSTRUCTIONS TO TENDERERS


EXAMINATION BY TENDERERS: Prior to submitting the tender, each tenderer must do following steps. (a) Tenderer must have to v isit the site, site condition and check site difficulties and discomfort ness at bore well site location. (b) Examine all instructions, eligibility criteria and specifications in the tendering document. (c) Familiarize he with all central, state & local laws, ordinance, rules, regulations & codes affecting the services including the cost of permits & licenses required for the work at site. (d) No additional claim, discrepancy etc. shall be entertained after opening of tender. TENDER PRICES The Tenderer shall fill the prices in the schedules indicated in price schedule of the Tender Document. On acceptance, the prices shall be valid throughout the period of contract.

2.

3.

DOCUMETS COMPRISING THE TENDER 3.1 The original and duplicate tenders prepared by the Tenderer shall be in two cover comprise of the following components: Cover-A : Eligibility Criteria and Technical bid. (i) Tender fee & EMD sealed cover. (ii) Technical tender documents with all experience certificates and eligibility Criteria documents. (iii) Executed orders details with Xerox copies of order. Cover-B : Price Schedule Cover (i) Tender price schedule duly filled.

4.

EARNEST MONEY DEPOSIT The Tenderer shall furnish, as part of its Tender, Earnest money Deposit for the amount as indicated in the invitation for tender. 4.1 The EMD shall be denominated in Indian rupees and shall be in one of the following forms: (A) E.M.D by Cash / Local MICR cheque / pay order / demand draft / bank guarantee drawn of Nationalized Bank in favour of Municipal Commissioner Ahmedabad valid for 120 days. 4.2 Any Tender without EMD will be rejected by the Ahmedabad Municipal Corporation as non responsive 4.3 Unsuccessful Tenderers Earnest Money will be discharged / returned as promptly as Possible after the award has been finalized. 4.4 The successful Tenderers Earnest Money will be discharged upon the tenderer signing the Contract and furnishing the performance / security deposit. 4.5 No interest will be paid on Earnest Money deposit.

5.

TENDER VALIDITY 5.1 Tender shall remain valid for 120 days from the date of price bid opened . Tender valid for a shorter period may be rejected by the corporation as non-responsive.

6.

FORMAT AND SIGNING OF TENDER 6.1 The Tenderer shall prepare two copies of the Tender clearly, making one ORIGINAL and other DUPLICATE. 6.2 The original and duplicate of the Tender shall be signed by the Tenderer or a person or persons duly authorized to sign the Tender. The power of attorney in favour of the person authorized to sign the Tender shall accompany the Tender. All pages of the Tender must be duly signed by the tenderer. SUBMISSION OF TENDER 7.1 The Tenderers shall seal the original and duplicate of the Tender in one sealed envelope. 7.2 Tenderers are requested to submit the original and duplicate tender documents in two separate sealed envelopes and as per procedure given hereunder:(A) The Sealed Cover A (Technical Bid, Tender Fee and EMD Cover) Containing two sealed covers namely cover I and II (i) Cover I (EMD and Tender Fee Cover) It will contain only demand draft or pay orders payable at Ahmedabad or cash receipt. (ii) Cover II (TECHNICAL BID COVER) It will contain eligibility criteria and technical bid. (B) The sealed Cover B (Price Bid Cover) It will contain price schedule bid in which the prices are to be quoted by the tenderer. ( copy of price bid and duplicate copy of price bid should be in a separate cover ) No condition will be accepted along with the price bid. 7.3 Both the envelopes as mentioned above form the Tender and will be placed in a sealed common envelope. The envelopes shall indicate the name and address of the Tenderer to enable the Tender to be returned unopened in case it is declared Late Tender. The outer envelope shall be addressed at the following address by regd. A.D. Post. / Speed post / Hand delivery. To, Tender Officer, Ahmedabad Municipal Corporation, Sardar Patel Bhavan, Danapith, Ahmedabad 380 001. OPENING OF TENDERS 8.1 8.2 The tender will be opened in the office of the Tender Officer of Ahmedabad Municipal Corporation by Tender Officer on due d ate at 4.00 p.m. hrs. in the following manner: At the time of bid opening first tender fee and EMD cover will be opened. Then after only technical bid of all the tenderers having EMD and tender fee will be opened. After scrutiny of technical bids, the price bid of those tenderers will be opened who satisfy the eligibility criteria at a later date. The price bid of those tenderers not satisfying criteria shall be returned to them unopened. The Tenderers representatives who are present shall sign a register or paper evidencing their attendance.

7.

8.

9.

Municipal Commissioner reserves the right (i) to change, alter or to waive any technical or commercial terms, conditions and qualification (ii) to reject all the tenders or the lowest or any other tender in part or full without assigning any reason whatsoever (iii) for making changes / relaxation in eligibility criteria at any time (iv) to split the tender and award to more than one tenderer in the interest of public. The tenderer s shall have no cause of action or claim against the corporation or its officers, employees, successors or assignee for rejection of his tender.

10.

SIGNING OF CONTRACT 10.1 On receipt of the notification of Award / order the successful tenderer has to execute the necessary agreement with the corporation as per the prevailing rules & regulation of corporation, along with performance / security deposit. Contract shall be constituted according to and subject to laws of India and State of Gujarat and under the jurisdiction of court of Gujarat at Ahmedabad only.

10.2

11.

SECURITY DEPOSIT 11.1 On receipt of notification of award from the corporation, the successfully tenderer shall furnish 5 % security deposit in accordance with the conditions of contract, in the form acceptable to the corporation within 15 days. Failure of the successful Tenderer to comply with requirement of above clause shall constitute sufficient grounds for the annulment of the award and forfeiture of the EMD, in which event the Corporation may make the award to the next lowest evaluated Tenderer or call for new Tenders.

11.2

Tenderers signature and stamp & Date:-

( B ) INSTRUCTIONS TO THE TENDERER. 1.0 Invitation to Tenderers : 1.1 Municipal Commissioner for and on behalf of Ahmedabad Municipal Corporation, here in after referred to as the corporation, will receive tenders for the construction, drilling, installing housing, casing, & strainer pipes, gravel packing, development of tube -well for deep bore according to the specification, documents. The Tender shall be opened in the office of Tender Officer in the presence of Tenderer or their representatives who are present. The corporation reserves the right to reject all the tenders or, the lowest or any other tender, or part of it which in the judgment of the corporation does not appear to be in the best interest and the tenderer shall have no cause of action or claim against the corporation or its officers, employees, successors or assignee for rejection of his tender.

1.2

2.0

General Note : 2.1 2.2 2.3 2.4 2.5 The tender should furnish a copy of R.T.O. registration book for Drilling Ring. The tender should furnish their supervisor, technical, skill and un-skill staff details w ith qualification and experience. The tenderer must give va lidity of the tender for minimum period of 1 20 days from the date of price bid opened.. Any conditional tender will not be considered for evaluation. Municipal commissioner may consider the tender for evaluation which is not fulfilling above qualification and basic requirements in the interest of public.

(C) 1.

Condition of tender for construction of deep bore well. Successful tenderer will have to start the drilling work within 15 days from the date of order. The TOTAL work shall be completed within 120 days of the date of order . The work of drilling the new bore will have to be started immediately on showing the exact site and work of all bores should be completed within the time specified above. Payment--Corporation will not consider any advance payment for material and labour. 60% payment of the work will be given after completion of air-compressor de velopment work and supply of all electrical and mechanical materials of related bore well. Out of remaining 40%, 30% payment will be given after successfully commissioning of tube-well. (after sub-pump development work, sounding test, site clearance, verticality test, etc.), 10% will be released three months after successful commissioning. (i) If the contractor will not complete any of the above work as mentioned in the tender due to any reason, the payment for the work done will not be given to the contractor till work is completed satisfactorily . (ii) The contractor shall submit the data chart in triplicate test certificates of pipes and strainers, air compressor and submersible pump development certificate, acceptance test certificate along with the bill and the payment of the bill will be given normally within 45 days of submission. No other terms of payment will be accepted. The contractor shall have to keep qualified technical representative for full time to receive instruction. The contractor shall be responsible for workman's compensation if any such case of death or injury. During the work any damage to the AMC'S property that will be recovered from contractor's account. The contractor shall h ave to keep record of workers working on site and will have to submit every week. The rates shall be stated clearly in words and figures in schedule of rates.
9

3.

4. 5.

6. 7.

8. 9.

If any extra item comes up during process of work the same shall be carried out by the contractor and shall be paid at the rate fixed up by the Municipal Commissioner if not mentioned there. Contractor should provide details and proof of possessing the following machineries required for construction of tube-well in absence of such pr oof his offer will not be considered. No 1 2 3 4. Item Drilling rig (R.T.O. Regi. No.) Drilling rod dia & length Bore developing 125/85 HP sub pump Any other machineries Capacity Year of Purchase

11. 12. 13. 14 .

15.

16.

17.

18 .

Municipal Commissioner reserve the right to accept or to reject any tender in part or full without assigning any reason what so ever. No terms of payment of the contractor will be accepted. The housing pipes, casing pipes and strainer pipes, reducer etc. are to be brought by contractor at site. The materials must be as per technical specification given in the tender documents. Contractor has to make his own arrangement for water required for construction of bore. In any circumstances water and water tanker will not be provided by Corporation. Any other terms of tenderer for water tanker will not be accepted. Minimum 13 brass gravel of proper size (3/16" to 5/16") shall be brought at site by contractor before starting the pipe lowering and should be stacked in chattas for quantity measurement by AMC. After gravel packing, clay packing air compressor development bore must be developed by submersible pum p having discharge capacity of 100 m3/hr at 140 mtr. head of 125/85 HP sub pump within 7 days, otherwise corporation will make its own arrangement for bore development by sub pump set and for this work amount as decided by Municipal Commissioner up to maxi. Limit of Rs 50,000/- will be deducted from contractors bill. If bore cannot be developed successfully as per specification no payment will be made. Performance Guarantee: Performance guarantee for satisfactory working of bore for the period of three years should be given in the form of bank guarantee of Rs.1,00,000/- for Each bore well kept valid for two years from the date of completion of last bore. During the performance guarantee period if necessary contractor shall have to clean and redevelop the bore by air compressor to get clear sounding of the bore. Municipal Commissioner reserves the right (i) to change, alter or to waive any technical or commercial terms, conditions and qualif ication (ii) to reject all the tenders or the lowest or any other tender (iii) for making changes / relaxation in eligibility criteria at any time (iv) to split the tender and award to more than one tenderer in the interest of public. The tenderers shall have no cause of action or claim against the corporation or its officers, employees, successors or assignee for rejection of his tender.

. .

Tenderers Signature & Stamp

Addl.C.E. (W.O.E.&M.)

10

Bank Details Name of Party/Contractor:Address:-

Telephone No.:E-mail ID :PAN No.:Name of the Bank:Name of the Branch:Address :-

Account No:Type of Account:MICR No:IFSE code No:-

The information given above are true to the best of my knowledge and belief.

Partys Stamp & Signature

11

BANK GUARANTEE for EARNEST MONEY DEPOSIT / SECURITY DEPOSIT / PERFORMANCE BANK GUARANTEE In consideration of the Municipal Corporation of the city of Ahmedabad (hereinafter to as the corporation) having agreed to exempt ______________________________________ (hereinafter referred to as "the said Contract") from the demand of earnest money / security deposit in cash for the due fulfillment of the terms and conditions of the agreement made between the corporation and the said BIDDER on ____________________________________________ for

________________________________________________________________________ (hereinafter referred to us "the said agreement") on production of Bank Guarantee for Rs._________________ Rupees ____________________________________________ only.

We

___________________________________________________________________

Bank

(hereinafter referred to as "Bank") do hereby undertake to pay to the Corporation as a amount not exceeding Rs. _____________________________ Rupees

_______________________________________________________________________ only on the demand from Corporation.

Any such demand on the bank shall be conclusive as regards as amount due and payable by the bank under this guarantee. However, liability of the bank under this agreement shall restricted to as amount not exceeding Rs. ___________________________ Rupees

______________________________________________________________________ only. We the bank further agree that the guarantee herein contain shall remain in full force and effect during the period that would be mentioned in the bid and that it shall continue to be enforceable till all the dues of the Corporation under or virtue of the said agreement have been paid and its claim satisfied or discharged and till a certificate to the effect has been received by the bank from the Corporation. However, unless the demand of claim under the guarantee is made to the bank in writing on or before the _____________________ (specify the date) the bank shall be discharged from all liabilities under this guarantee. With the bank further with Corporation sha ll have fullest liberty, without the concert of the bank without effecting in any manner it obligations herein under to vary any of the terms and conditions of
12

the said agreement or extend time for validity by the said bid from time to time or to postpone for any time or from time to time any of the powers exercisable by the Corporation against the said Contractor and to forebear to enforced any of the terms and conditions relating to the said agreement and the bank shall not be relieved from liability by reason of any such variation, or extension granted to the contractor for any forbearance, at Contractor or by any such matter or thing whatsoever which under the law relating to sureties would, but this provision, have the effect of so relieving the Bank. We ________________________________________________________________ the bank

undertake not to revoke the Guarantee during currency except with the previous concert of the Corporation in writing.

Dated the ________________________ day of ________________________ of 2010.

For ____________________________________ Bank

Principal (Contractor)

Surety (Bank)

Contract No.

and date of Contract

13

SECTION : III Tender Technical Specifications for Construction of tube-well in Ahmedabad City GENERAL: The purpose of constructing the tube -well is to obtain optimum quantity of ground water of good potable quality for drinking purposes. The deeper tube-well will go to a approx. depth up to 300 mts. from ground level. In this case the first 170 mts. approximately will have M.S. ERW housing pipes of 350 mm. dia. The minimum thickness of housing pipe will be minimum 7.00 mm. From 170 mts. onwards below ground level, there will be 250 mm. dia. casing pipe having a minimum thickness of 7.00 mm. pipes as per IS 3589/1981 and Johnson filtration make 250 mm. dia. heavy duty strainer pipes for deep tube -well to be used. The quantity of this housing and casing pipe will vary according to the requirement at the site but the tube-well is not expected to 300 mts. below ground level. In the case of deep bores about 120 M /hr or discharge is accepted with a draw down of 10 mts. I. Definition: In this contract a tube -well will mean: (a) Satisfactory completion of bore hole drilling the maximum prescribe d depth in a ll sorts of soil, kankar, boulder or soft or hard rock. The stated depths are approximate and the contractor may have to go higher or lower depth as decided by Corporation as per condition of starter generally available in the locality. The contractor has to arrange for electro logging and cost has to be given in prices schedule separately. (b) The installation of casing and housing pipes, complete with strainer or slotted pipes including bail plug, reducer, clamp top half coupling a nd well ca p. The housing pipes casing pipes, Johnson strainer pipes, housing pipe clamp wooden slippers well cap, half coupling and cone of bail plug will have to be supplied by the contractor. 50 mm width x 4 mm thick M.S. strip for welding between two housing pipes and chapla should also supplied. (c) Placing of a gravel packing of minimum 13 brass quantity around casing, housing and strainer pipes as per design. All gravel as per specifications of required quality of (and) quantity will be. supplied by contractor. (d) Strata wise development of gravel packed tube-well with adequate capacity of air compressor . (e) The development of gravel packed tube-well with submersible pump with the object of obtaining a minimum yield of 100M /hr at 140 mt. head of 125/85 H.P. sub -pump till water become potable and nearly sand free. (f) Measuring eccentricity and sounding. 2. Drilling procedure : (a) (b) (c) The contractor will employ the hydraulic direct rotary (i.e. by direct rotary drilling rigs fitted with a heavy duty reciprocating mud pump) All water bearing strata decided by the engineer in-charge shall be tapped. The contractor shall have to drill first a pilot bore of 9" diameter but not more than 12" diameter after completion of which the contractor shall have to inform engineer in charge for electro logging. Contractor will have to arrange for electro logging of each bore. Without electro logging of bore rimming work should not be started in any case. After pipe & strainer lowering in the bore hole and before gravel packing, minimum 12 hours back washing is required to keep proper mud density. After gravel packing work, minimum 24 hours back washing is required with clean water, putting washing line at the bottom. The contractor shall have to use fresh quality of Bantonite so that the mud salinity should be less than 230 PPM. Bore hole shall be drilled freely in plumb & vertical.
14

(d) (e) (f) (g)

3.

Material to be supplied by the contractor All housing pipes, casing pipes and strainer pipes shall be supplied by the contractor. The contractor shall be responsible for all the losses or damage for any reason.

4. Bore Hole (a) Minimum dia. of 650 mm. from ground level to a depth of 3 mts below the bottom end of housing pipe should be drilled for which payment will be given. On completion of 650 mm. dia. running size of rimmer bit should be checked in and measured by AMC engineer in-charge after removing from bore hole. Minimum dia. of 550 mm- from 3 mts. below reducer to 3 mts Below the bottom end of the casing pipes should be drilled (for which payment will be given ) on completion of 550 mm. dia. running site of rimmer bit should be checked in presence of engineer in-charge. Pipes, Strainers & Materials: The contractor has to arrange to supply 350 mm. dia. M.S. ERW new pipes confirming to IS 3589/1981 and 1SI mark and minimum wall thickness of 7.0mm with square edge finish with suitable chapla welded. The acceptance make of the pipes are Jindal/Ajanta/Surya Roshni/Lloyd and Asian as per IS. The contractor has to provide materials test certificates from the respective manufacturer. The individual length of the pipes should not be less than 5 mt (5 mt < pipe length < 7 mt) 250mm dia MS ERW black casing pipes: The contractor has to arrange to supply 250 mm. dia. M.S. ERW new pipes confirming to IS 3589/1981 and 1SI mark and minimum wall thickness of 7.0mm with square edge finish with suitable chapla welded. The acceptance make of the pipes are Jindal/Ajanta/Surya Roshni/Lloyd, Wellspun and Asian as per IS. The contractor has to provide materials test certificates from the respective manufacturer. The individual length of the pipes should not be less than 5 mt (5 mt < pipe length < 7 mt) 250 mm. dia Johnso n make strainer pipes : Johnson filtration make new strainer pipes to be manufac tured from LOG materials. Diameter of screen pipes to be 250 mm. and should be suitable tensile strength & collapsible strength should be more than 28 metric tonnes and 30 kg/cm2 respectively for which certificate should be attached. The openings of screen required are 1.00 mm. and 1.5 mm. according to the strata available at the site, the screen should be used. The contractor should give rates for the both sizes of the screen. 350x250 mm dia. Concentric steel cast reducer:- The reducer should be steel casted confirming to IS 216/1971 and machined finish as per the instruction of site in charge engineer. it should be fixed or flexible. Bail plug: - The bail plug should be prepared from 250 bail plug length should be 5 mts. with 55 mm length x 1.5 mm width, 2900 no. slots in 3 mt. Length of bail plug at the bottom. Eccentricity:All drilling & pipe lowering shall be done in plumb and vertical as far as practicable but within the following limits of verticality. Maximum allowable deviation should not be more than 3" in every 100 feet. Depth and proportionally up to 400 ft.

(b)

5 (a)

(b)

(c)

(d)

(e) (f) (1) (2)

Construction of Tube -well: After satisfactory drilling and bore hole rimming the contractor has to arrange lowering, installing & welding of housing, pipes, casing pipes and strainer pipes including , reducer, bail plug, housing pipe, joint covering strip, coupling, well cap etc. The contractor has to bring all the materials like bore pipes, strainer pipes, well cap, cone, etc. two days prior to lowering with necessary test certificates for approval of engineering in charge. The contractor has to obtain written permission from the engineer in charge only these af ter he can start lowering of the pipe in presence of AMC engineer. The clamp applied to the housing pipes supporting to the pipe 0.5 mt. below the ground level and supported with wooden slippers. Before lowering housing and casing should be paint with black anticorrosive bituminous paint.
15

Gravel Packing . After successful completion of pipe lowering gravel packing operation should be started. The gravel used should be graded hard well rounded particular 4.75 mm. 'to 8.00 mm. size. Minimum 13 brass gravel should be used in each tube-well the gravel packing operation should be continuously carried out till it is completed. The clay packing should be done from ground level to 300 ft. depth. Air compressor development. The contractor has to arrange 1000 CFM Air-compressor with 250 PSI capacity compressor at site for this work. He has to develop each strata of the tube-well with 5" dia. education pipe and 2" dia. air line. The end of the education pipe should be kept in the centre of each strata. The A ir compressor development work should be carried out for 12 hour from upper strata to lower strata in turn & lastly at the bottom of the tube-well still water coming out from all the strata become send free. And second stag Air compressor development with 1000 CFM Air -compressor with 250 PSI capacity with Direct 3" dia. Air line of 800 ft. depth for 12 hour. During compressor development the water coming out from the tube-well should be used to setting the gravel and clay around the tube-well. The contractor has to give clear sounding of the tube-well after A ir compressor development. Air compressor development should be run for minimum 24 hours. It will be the contractor's responsibility to make arrangement for disposal of mud and water during air compressor development. Final development of bore with sub-pump. After compressor development successfully carried out tube-well is to be further develop by submersible pump having discharge capacity approximately 100 m3/hr at 140 mtr. head of 85 HP sub-pump with 6" column pipe till discharge water become sand free. If possible at site necessary electric supply will be provided by AMC and the cost per unit will be reimburse from the bill. If power supply from AMC is not possible the contractor has to arrange generator for this work. It will be the contractor's responsibility to make arrangement for disposal of water in the drainage during sub-pump development. The water Tanker The water tanker for work of drilling and developing for the tube -well will not be provided by AMC in any circumstances. The contractor has to arrange for water tanker at its own. Acceptance test After development of tube-well by submersible pump the contractor has to give sounding test of tube-well. If the bore is filled the same has to be removed by air compressor. The contractor has to clean the site and level the site after completion of work. Mud Disposal The bore will be constructed in the. city of Ahmedabad. Due to city conjunction and space problem in the city, the tenderer must dispose off mud and cutting day to day during construction of bore. It should not be staged at site. It will be the constructor's responsibility if any accident, police case, death, court case, injury happen due to not properly dispose off mud and cutting from the bore site. Penalty We have mention 90days period for completion of tube -well in all respect as per tenders specifications. If the contractor could not complete the work in specified time penalty at the rate of l % per week for delay completion of tube-well with maximum ceiling of 10 % will be charged . If work is not completed during this penalty period than contract will be terminated, security deposit will be forfeited and party will be black listed.
16

Performance guarantee: The contractor has to give performance guarantee of Rs. 1,00,000/- for Each bore well in the form of bank guarantee for the period two years for the tube -well last constructed out of total no. of ordered bore AMC approved bank. During performance guarantee if necessary, contractor shall have to clean and redevelop the bore by air compressor to get clear sounding of the bore. Certificates: (a) (b) (c) (d) (e) (f) (g) The contractor has to give following certificates. Material test certificate and routine test certificate for 350 mm. dia. M.S. ERW pipes as per IS 3589/1981. Material test certificate and routine test certificate for Johnson filtration make Continuous slotted strainer pipes. Strata chart drawing with showing all the technical details in triplicate. Compressor development report with details for all the strata in triplicate. Submersible pump development certificate mentioning nos. of hours pump run, discharge static water level, drawdown, pumping water level. Verticality test certificate for 400 ft. depth of the tube-well at 0 to every 10 ft. Acceptance test certificate for clear sounding of tube-well and site properly leveled and cleaned and cavity around the tube-well duly packed with clay, well cap, bore pipe, clamp, wooden slipper, earthing terminal and half coupling on the top of the pipe.

Tenderers Signature & Stamp

Addl.C.E. (W.O.E.&M.)

17

18

The scope Includes Supply, Installing and commissioning work of following Electrical & Mechanical equipments . (a) Submersible pump sets w ith 3x25 mm2 PVC insulated copper flat cable of 150 mt. Double length suitable for Star/Delta starter. Make/ Discharge / Head / Construction of material / flat cable should be as per attached Annexure I & II etc. Pump should be connected with 150 mm dia. One side flanged and one side threaded match with NRV thread. M S ERW pipe of 0.3 mtr. Long. Tenderar should give technical details asked in Annexure I & II. Column Pipes : Column pipe should be 150 mm dia. minimum 5.4 mm thickness galvanized, confirm to IS 1239 (Part I) of 1988 and both ends should tee have welded flanged as per attached drawing and flange to flange, length of the Column pipe should 4.0 to 4.3 mt. And total length of Column pipe should be 140 mts. The Top piece should be of 0.3 mt in length and 150 mm dia and one end welded flanged as per drawing aid another side flange should be as per flange standard B S table - C. All the Column pipe should he assembled by 3.0 mm thick rubber Insertion sheet with M S hexagonal headed 12 mm x 45 mm GKW make nut bolts and plain washer at both ends. The detailed technical requirements are as per annexure III & IV. The tenderer should give technical details in annexure III & IV. C. CIDF Pipes / specials & Valves. CIDF Pipes, Specials and valves should be as per following.

( b)

Sr. No. 1 2 3

Items 150 mm dia 90 short bend with flanged drilled as per B.S. Table C and bend as per IS 1538/1993 150 mm dia 1.0 mt. length CIDF pipes of class B as per IS 7181/1986 and flange drilled as per BS table C 150 mm dia CIDF sluice valve with hand wheel as per IS 780/1980 PN-1 rating.

Qty 2 nos (per each bore) 1 No (per each bore) 1 No (per each bore)

The technical details & specifications as per annexure V & VI. All the cast Iron double flanged pipes, specials and sluice valves should be connected by 3.0 mm thick rubber Insertion sheet and (16 mm x 90 mm) S/8* x 3" MS hexagonal headed GKW make nut bolts & plain washers (5/8" plain washers). Section Pillar fitted with switch starter panel, capacitor, lighting board duly painted with two coat of silver oxide paint. (One coat of primer and than two coat of silver oxide paint). The rating of the switch should be 250Ampx 440V. with TP&N w ith neutral link. The starter should be suitable for 85 to 120 HP motor and should be air break star delta starter. Rating of the contactor should be 200 Amps for AC-3 duty condition. The Detail technical specifications are as per annexure VII. The contractor has to connect main incoming cable to SFU and flat copper cable in the starter by crimpling "DOWELLS" make heavy duty cable sockets. Earthing of the section pillar, Switch unit & starter should be done by 1 x 1/8 MS galvanized earthing strips.

19

(e) I. II.

Miscellaneous Items : Bore Cap: From 5 mm thick MS sheet should be prepared as per drawing. Flat Cable binding nylon c ore : Every pipe Joint flat cable should be bound with nylon core of ( 1/16'). Heavy Duty MS clamp for Column pipes with nut bolts: It should be made from 4"x 3" mm thick X 24' length: as per drawing Contractor has to submit report with following data :I. Static, water level of the bore well. II. Pumping level of the bore well III. Discharge of sub pump in m3/hr. IV. Ampere, Volt meter, Power factor etc. reading for 4. hour working of sub-pump. Commissioning of the sub pump-set should be in presence of site engineer or in-charge. Guarantee: 12 months from the date of commissioning and 18 months from the date of supply for all the equipments. During erection work any injuries to the contractor's staff is the responsibility of the contractor.

III, IV.

V VI.

20

Annexure -I Specification for Submersible Pump Sets with 150 mtr. head and 80 m3/hr discharge capacity at duty point
Sr. No Technical Description of material AMC Requirements Tenderer's (Bidder's) offer

1 2 3 4 5 6 7 8 9 10 11

Make Duty point discharge capacity Duty point head Minimum efficiency of pump(only) at duty point Minimum efficiency of submersible motor(only) at duty point Minimum overall efficiency of pump set at duty point Motor rating should be higher capacity Rated speed in RPM Operation Rating Solid handling capacity Maximum outside diameter x 250>x>210 Connection
Sub pump set cable: PVC insulated Water proof flat copper cable of 5+5 mt length

KSB /LUBI/U -Neel 80 M 3/hr 150 Mts. 68% 82% 56 % 10 % minimum 2800 continuous fine sand particles For 250 mm dia . bore well and must not less than 210 mm
Star -Delta 2 x 3 x 25 Sq. mm (Double cable)

12 13 14 15 16 17

18

Type of pump Type of impellers Rated voltage/No. of phases/frequency Variation (a) Voltage (b) Frequency (c) combined Materials of construction (a)Casing (b)Impeller (c)Shaft (d)Bush/Neck ring Sub. motor will confirm to IS Specification no Sub. pump-set will confirmed to IS specification no Pump set liquid Suction strainer Inspection & testing of sub-pump set Minimum H.P. of submersible Motor required

Mix flow Semi open/Enclosed 415V/3/50Hz +/- 10 % +/- 5% +/- 10 % C.I.FG 200 SS 316/Crom steel/Gun Metal AISI 410 or ASTM A 276 leaded tin bronze gr 4/5 IS : 9283-1995 with latest revision IS : 8034-1989 with latest revision Bore well water SS 316 At manufacturers works if required by AMC H.P. -70
Add.C.E. (W.O.E& M)
21

19 20 21 22 23 24

Tenderers signature and stamp

Flat Cable Annexure -II Sr. No. 1. Technical Description of Material A.M.C Requirements Finolex, Goodcab Unistar , Emgee, Torrent 3 core x 25 mm2 Tenderer's (Bidders)

Make

2.

3.

4. 5. 6. 7. 8. 9. 10.

Size of the PVC insulated and Sheathed water proof flat copper flexible cable. Rate to be furnished per meter Copper flexible conductor having electrolyte annealed bright flexible copper conductor with high conductivity copper write PVC insulation Outer sheath No. of cores and color Insulation Insulation Thickness (Minimum) Shape Sheath (a) (b) (c) colour insulation Type Gulty

Confirming to IS : 8130/1984 Confirming to IS : 5831/1984 Confirming to IS : 5831/1984 3 core red, Yellow, Blue PVC type A 1.2mm minimum Flat Cable Black PVC type St 1 Impressive to water greases, Oil etc.

11.

12.

Test Certificate (a) Type test certificate \ (b) Acceptance Test Certificate (c) All routine test certificate (d) Additional Ageing Test certificate from recognized Testing institute Certificate from the Manufactures or authorized stockiest or dealers should submit by tenderer regarding purchases of the flat cable from whom material purchased.

Required Required Required Required

Required

Tenderers signature and stamp

Add.C.E. (W.O.E& M)

22

Column Pipe :Annexure - III


Sr. No. 1 Technical Description of Material Make of galvanized pipe for column pipe A.M.C Requirements Jindal, Lioyds, Prakash Surya, Ajanta, Tata, Asian minimum 5.4 mm 150mm dia New Pipe 4.3 meter 4.0 meter One piece (Joint less) I.S. 1230 part I 1990 Confirmed (must) Required Not allowed Per mater Both ends (2 nos) As per attached drawing 8-5/8 dia 8 nos 8/16 1-7/8. 2 nos 18mm thick 2 nos. 9-3/8 dia 8-1/89 inch 8 nos 80mm Sunarc / In both sides of flanges V grooves. Faces duty turned on lathe m/c Both the flanges must be parallel and right angle to the axis of the pipe Attached Three coat of black color anti -corrosive bituminous point Required from manufacturers works Tenderer's (Bidders)

2 3 (I) 3(II) 4(a) 4(b) 4(c) 4(d) 4(e) 4(f) 4(g) 5 6

Minimum wall thickness of column pipe Size of the column pipe Quality of the pipe for the column pipe Length of the Coolum pipe Minimum length of the column pipe Pieces of pipe for column pipe I.S Specification of pipe for column pipe I.S.I mark Makers emboss mark Negative tolerance in thickness Rates of column pipe to be furnished Flange of the column pipe a. no. of flanges b. Type of column pipe flanges c. P.C.D. of the 8 no. of the holes at equal Distance d. No. of holes e. Dia of the 8 no holes f. Flat cable slot g. No. of cable slot h. Thickness of the flange i. O.5 mm (1/2mm) deep grooves in the face of the flange j. Outside dia. of the flange k. Square flat face distance between two cable slot Gusset for jointing flange with the pipe a. No. of gusset b. Size of gusset Welding of flange with the pipe a. Welding of rod make b. Welding process Face of the column pipe flanges a. Machining b. Faces of flange

10 11

Drawing Color of the column pipe

12

Inspection & Testing of pipe for column pipes

Tenderers signature and stamp

Add.C.E. (W.O.E& M)

23

Sr. No 1 2 3 4 5 7 8 9

10

ANNEXURE IV Nut Bolts (12 mm x 45 mm) Technical description of material A.M.C. requirements M.S. nut bolts size 12 mm dia 45 mm length Make As per IS 1363 Standard Specification As per IS 1383 Emboss mark of make & mechanical Required properties on hand Type of head Hexagonal Sample approval Required Test certificate Required Certificate from the manufacturers or Required authorized stockiest or dealers should submit by tenderer regarding purchase of the nut bolts from them Plain washer (1) Inner dia. Washer (2) Outer dia of washer 1 (3) Thickness of washer 2.0 TO 2.5 MM (4) Material M.S. Rubber Insertion Sheet Technical description of material A.M.C. requirements Size of canvas enforced rubber (reinforced) insertion sheet. (to be used between column flanged joint) Colour Standard specification ISI mark Sample approval Certificate from the manufacturers or authorized stockiest or dealers should submit by tenderer regarding purchasing of the rubber canvas enforced rubber insertion sheet from them. 3.00 mm thick i.e. 1/8 thick White As per IS 688/1265 Required Required Required

Tenderers (bidders) offer

Sr No. 1

Tenderers (bidders) offer

2 3 4 5 6

Tenderers signature and stamp

Add.C.E.(WO E&M)

24

ANNEXURE V-A SLUICE VALVE Sr Technical Description of material No (A) Make of CIDF sluice valve 1 2 3 4 5 Size of sluice valve Standard specification Class of valve Working pressure Type A.M.C. Requirements Tenderers (Bidders) Offer

6 Material of spindle 7 Material of Nut 8 (i) Flanges of the sluice valve (ii) Hole of the flanges 9 ISI mark embossed 10 Test certificate of manufacturer 11 Certification from the manufacturers or authorized stockiest or dealers should submit by tenderer regarding purchase of the sluice valve from whom material purchased

Geeta /Upadhyaya,/IVC, IVI/Hawa/ Kirloskar 150 mm dia As per IS 780/1280 P M-1 10 kg / cm2 Non rising spindle type and closing on clockwise rotation AISI 416 Leaded gun metal Flat, Face As per BS table C Must required Must required Required

Annexure V-B CIDF SHORT BEND Sr N o Technical Description of material A.M.C. Requirements Tenderers (Bidders) Offer

C.I.D.F. short bend: 1 (i) size of sluice valve (ii) bend degree 2 Standard specification 3 Flanges hole drilling 4 Marking on pipe

150 mm dia 90 (short) As per IS 1538/1993 As per B.S. Table C As per chass B of IS 1538/1993 5 Make 6 ISI emboss mark Must required 7 Certification from the manufacturers or Required authorized stockiest or dealers should submit by tenderer regarding purchase of CIDF 150 mm dia short bend from whom material has been purchased .

Tenderers signature and stamp

Add.C.E. (W.O.E& M)

25

ANNEXURE VI C.I.D.F. PIPES Tenderers (Bidders) Offer

Sr No (I) 1 2 3 4 5 6 7 8 (II) A B C D E F

Technical Description of material C.I.D.F. pipes requir ed Size Length Type of casting Standard specification Flanges hole drilling Marking on pipe Make ISI emboss mark

A.M.C. Requirements For water 150 mm dia (6 dia) 1.0 meter Horizontally or vertically cast double flanged pipes class B (heavy) As per IS 7181/1986 As per B.S. Table C As per class B of IS 7181/1986 Tenderer should mention Preferred

M.S. Nut bolts size Make Standard I.S. Specification Emboss mark of make & mechanical properties Type of head Plain washer (i) Size (ii) Material

16 mm dia (5/8) GKW/TVS/DELTA/ISWP As per IS 1363 Required Hexagonal

Tenderers signature and stamp

` Add.C.E. (W.O.E& M)

26

Annexure VII Specifications f o r Air Break Star -Delta Switch Starter Panel with Section Pillar Supply of fully automatic air break star -delta switch starter panel suitable for submersible pump for operation on 415V 1.0%, 3 phase, 50 3% Hz AC supply. Control panel shall consist of isolator & SFU, HRC fuses, contactors. 0/L relay, single phasing preventer, earth leakage relay, capacitor and accessories. Submersible Pump Set H.P.-70/85 (a) Enclosure : Enclosure shall be dust and vermin proof, wall mounting cum pedestal type and having lowers on upper and lower side of panel board. The fabrication box shall be of 16 SWG CR sheet and door shall also be of 16 SWG CR sheet. All the components Inside the control panel shall be mounted on 16 SWG steel base plate. After applying Zinc cromate primer, the control panel shall be stoved enameled with two coats of final paints. The colour shade shall be of 631 of IS : 5. All bolts, nuts, screw washers shall be galvanized, zinc/cadmium plated and passivated Proper rubber lining shall be provided for protection from dust. There shall be two entry for main cable to the switch and .two outgoing cable entries from the starter. These shall be provided with suitable cable glands made of bi .sss metal. (b) Isolator SFU: This shall be of 300A x 415V air break, quick make quick break type confirming to IS : 4064 (Part I) 1978 suitable for AC-23 duty confliction. The operating handle shall be mounted on the door of the panel. The switch shall be interlocked with panel door to prevent opening ofthe door when the switch is 'ON' position and to prevent switching ON when the door is open. Combination SFU will not be acceptable. (c) Contactors : All the three contactors shall be air break type and having rating of minimum 200A for AC-3 duty utilization characteristic Coil voltage of 415V, auxiliary contacts 2 NO + 2 NC. (d) Overload Relay: The overload relay shall be 60-100 Amp Rating three element, positive acting, ambient temperature compensated type with adjustable setting range to ensure prote ction against single phasing and overload. The 0/L relay shall have manual reset facility. The range of the overload relay shall be decided by multiplying minimum .6 of minimum 1.5 times and maximum 1.6 times the HP rating of the motor. (e) Timer : Electronic timer for Star to Delta changeover shall be provided of the coil.. (f) Single Phasing Preventer : ( Pump Guard) S.P.P. with 2/3 seconds lag to avoid nuisance tripping shall be provided. SPP shall be of unbalance current operated type. A bypass toggle switch with mechanical Interlocking shall be provided on the door of the control panel to bypass the same in case of emergency. Minllec series 8800 make 40 AMP. (g) Main Fuses : 3 Nos. knife type HRC fuses of 160A, 415Bshall be provided. (h) Control Fuses : 3 Nos. 16A HRC fuse fittings with 2A HRC fuse links shall be provided for the protection of the control circuit. (I) Earth Leakage Relay : An E S R. with C.B.C.T. shall be provided of 10 mA to 600mA range. A bypass toggle switch with mechanical interlo cking shall be also provided on the door of control panel to bypass the same in case of emergency. The E.L.R. shall have 2/3 seconds time lay to avoid nuisance tripping. (j) Push Buttons : Push button of 22.6 dia shall be provided of red green black colors for stop, start and 0/L reset respectively.
27

(k) Indicating Lamps : LED/filament type indicating lamps of 22.5 0 dia shall be provided for R.Y.B. phases, SPP (healthy), F...R (Fault), 0/L.trip). Star and Delta. (1) Busbars and Links: Main bus bars and connecting links between, connectors shall be minimum of 1"x 1/8" size tinned electrolytic copper strip. (m) Wiring and Terminals : Power and Control wiring shall be done with PVC insulated copper conductor having 660/1100V grade; Control wiring shall be done with minimum 1.5 sq. mm. Copper wire and Terminated with compression lugs of proper size. Each wire shall be terminated at both ends with PVC ferrules. Not more than two wires to be terminated at one terminal and 10% Extra Spare Control Terminals, clip on type shall be provided. For connection of load side terminals, adequate copper bus link, shall be provided on conductor and overload may. (n) Voltmeter : Sq-96 size, 0-500V voltmeter shall be provided with selector switch to read voltage In each phase. , (o) Ammeter: Sq-96 size, CT operated ammeter of 0-200A, having 6 times suppress scale shall be provided along with selector switch to read current In each phase. (p) Earthing : Two nos of earthing terminal shall be provided for connecting the oarth, All non -current carrying metallic parts of the equipments shall be earthed. Earth bus of 10 x 3 mm shall be provided through out of the earth. (q) Name Plates : Labels shall be provided for each equipment mounted on the panel. (r) Accessibility: Checking, Testing, Fault finding and removal of components shall be possible without disturbing the adjusted equipments. Incoming supply terminal shall be shrouded with acrylic covers to prevent accidental contact. (s) Drawing : The tenderer must submit GA drawing/wiring diagram and bill of material prior to manufacturing. (t) Approval & Testing : After order and approvals of GA Drawing, wiring diagrams and bill of materials, the tenderer shall manufacture one panel which shall be approved by the engineer of AMC. Tenderer shall have to give following testing at his works at his own cost and risk. 1) Single Phasing in Each phase. 2) Under voltage cut off at 320V. 3) Over voltage cut off at 480V 4) Leakage Current Test. ' 5) Unbalance tripping at 10% unbalance voltage 6) H. V. Test at 2.5 KV for power circuit. 7) H.V. Test 1.5 KV for control Circuit. 8) Meggar Test. (u) Section Pillar : Cabinet height 5 width 4, depth 2, legs 3, fabricated from 40 mm x 6 mm size angle and 2.0 mm CRCA sheet of door and enclosure. It also requires following items : a) b) c) d) 8 lever Godrej make Navtal lock. One lamp holder point and one 3 pin 15 Amp plug point lighting board. . 4 nos. cable gland for 3.5 core x 12 mm2. Alu. cable and double entry cable boxes. Duly painted with 3 coat of light gray semi glossy shade 631.
28

(v) Capacitor : 30 KVAR capacitor. Capacitor shall be of mixed Dielectric -of polypropylene and paper with internal element fuses completely impregnated type non PCB oil. Capacitor with protection fuse. (vi). REMARK: The manufacturer must posses CPRI certificate for IP 55 test as per IS 2147 of 1962, and SOKA short circuit test (IS : 8G23, part I of 1993), for 1 second with Initial pick of 105.00 KA. The offer without CPW certificate or manufacturer who does not posses such certificate shall be straight away rejected. The contactors used inside the control panel shall be of one make only using of different makes of contactors is not at all permissible. Unless and until approved in writing, only following makers shall be acceptable. 1 2 3 4 5 6 7. 8 9 10 11 12 13 14 15 Contractors and O/L Electric Timer Meters CTS Selector Switch Indicating Lamps Isolater / SFU S.P.P. (Pump Guard) E.I.R. Pump Toggle Switch Wires HRC Fuses Terminals Capacitors L&T/SIMENS/ABB/CROMPTON L&T(GIC)/SIMENS/CROMPTON AEI/MECO/SHANTI/IMP AEI/MECO/ASHOK/ASHMOR SALZER/RECOM/KAYCEE/SWITRON VAISHNO/BASS/TEKNIC/C.T. STANDARD/L&T/SIMENS/CROMPTON HH-ELCON MINILEC KIRLOSKAR/E.E./DATAR/SUN TEKNIK/L&T/SIMENS/HH-ELCON VAISHNO/I.E.C./JAY FINELOX/ ATLAS/V PLAST/PYROFLEX STANDARD / L&T/E.F./HH-ELCON ELMEX/IEC ASIAN/SHAKTI/KHATAU JUNKAR/ABB/UNIVERSAL /SHAH SPREAD. ELECTROLITE COPPER.

16

Bus bar

29

DATA SHEET Sr. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 List of components 300A isolator SFU with door interlocking AC-23 duty 160A HRC main fuses 18Ax415 v HRC control fuses with 2A HRC fuse links 200 A Star contactor 200A main contactor 200A delta contactor Overload relay S/o changeover electronic timer Sq. 96 0 -500 V voltmeter Sq. 96, Suppress scaler, CT operated ammeter Current transformers Voltmeter selector switch Ammeter selector switch Pushbuttons for stop, start and o/l reset Indicating lamps for R.Y.B. SPP, ELR O/L, Star & Delta Single phasing preventor (pump guard) Earth leakage relay with CBCT Toggle switch to bypa ss SPP and ELR 30 KVR capacitor Section pillar As per IP55 Test Qty 1 3 3 1 1 1 1 1 1 1 3 1 1 3 8 1 1 2 1 1

I.S. Specifications: All items of switch starter panel shall confirm to their relevant specifications as under or its latest revision. IS: 4237: 1982 General requirements of switch gear and control gear voltage not exceeding 1000 volts. IS: 2959 : 1982 contactors IS: 4064 (Part I): Isolators IS: 3842 (Part- IV) Overload Relay IS: 8544 Motor Starters IS: 10118 Code of practice for installation and maintenance of motor starter. IS: 1248 Indicating installments IS: 2705 Current transformers IS: 2147 Degree of protection for starters.

30

ANNEXURE - VIII

Technical Specification for 315 Amps, 415 volts, 50 Hz TPN Switch Fuse Unit (SFU)
Make: - L & T, Siemens, Crompton, ELCON, English Electric, C & S. General Construction:1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) SFU must confirming to I S 13947-1993 (With latest /revised Amendment ) SFU must be dust proof. SFU must be triple pole with solid neutral. SFU with 160 Amp HRC DIN type porcelain fuse links.( DIN-I ) and fuse base should be of 400 Amp. (DIN -II) Made from, sheet steel enclosure. Fuse switch unit will not be acceptable. Combination fuse switch unit will not be consider for technical evaluation. Switch should be made from DMC (Dove Mould Compound) insula ting material having AC23 duty category. Switch must be separate unit. Fuse base must be separate unit for each phase for replacement & each fuse base. Switch and Fuse base should be mounted separately & they are interconnected with alluminum links. A separate front door opening should be provided for replacement of Fuse links. The fuse door must be such that, it can not be opened while the SFU is in 'ON' position. Tenderer with deviation in above technical specification will not be consider for evaluation.

Tenderer's Signature with Stamp Date :-

Add.C.E. (W. O. E & M)

31

ANNEXURE IX

Technical Specification of Section Pillar for requirement of 70/85 H.P. LTMD service.
(A) 1. 2 3. 4 5 6. The Design of Section pillar must be such that 70/85 H.P. L.T. service box and its equipments must be technically fit in it comfortably. It must have double door on front side and on back side. Section Pillar must be fabricated from 40 mm width x 6 mm thic k x 7 1/2 ft height size M.S. angle. Enclosure and door must be made from 2.0 mm thick CRCA sheet. Bottom of cabinet must be made from 4 mm thick M.S. plate. Cabinet internal Size must be of 39" width x 30" depth x 60" height. Cabinet must have internal two vertical compartments one side 17"depth and backside 13" depth. Height of compartment 4 ft and separated with wooden plates. In the compartment upper and lower side 6" opening required. It must be Dust proof, Rain water proof and Water jet spray proof. It must be as per IP55 test. Hinge of cabinet's door must be welded with angle of section pillar. Door must have internal stoppers to stop first closing door. 3 nos cable gland hole of 51 mm dia required in cabinet as per requirement. (One side one and back side two) Two nos, 6 levers Godrej Nav-Tal lock must supply with section Pillar. Light board with one lamp holder with switch and one 3-pin, 15 Amp Plug point and switch must be supplied with section pillar. One Main single phase DP switch cut out must supply with section Pillar. Section pillar must be duly painted with one coat Red oxide and two coat light semi glossy shade 631 from internal and outside. On bottom of legs 4" dia 3 mm thick plate must be welded. Four legs of section pillar must be fitted and welded with Tie Roads. Hinges of the door must be heavy and made from the 20 mm width x 6 mm thick strips with 8 mm hinge pin. The handle of both double doors of cabinet must be interlocked with first closing door.

7 8 9 10. 11. 12. 13. 14. 15. 16. 17. 18.

Tenderer's Signature with Stamp Date:-

Add.C.E. (W.O.E&M)

32

ANNEXURE X

Technical Specification of chlorine dozer machine


(1) CHLORINE PUMP:Pump shall be electronically, controlled diapharam type, with adjustable 0.5 to 5 Ltr/ hr of chlorine solution, with head of 5 kg/ cm2 & material of diapharam shall be of Teflon Rubber and Solenoid coil shall be single phase, 50 Hz 230V + 10% AC power supply operated. Pump set must have a manual speed and stroke controls. 32 " x 24 " x 24 " 100 ltr capacity with Level indicator and drain valve and top cover . PTFE double ball NRV. Shall be provided good quality with flexible HDPE pipe.

(2) SECTION PILLAR:(3) FRP TANK :(4) NRV : (5) PIPE:-

(6) SUCTION FILTER CUM FOOTVALVE:-Suction pipe with non-return injecting valve. (7) One No 15 Ltr, good quality plastic bucket & funnel with each dosing equipment set as per ordered nos. for each machine shall be given before commissioning of the system. Contractor has to do all works required to do for functioning of dozing machines such as supply & laying of required size of cable/ wire up to 20 mtr. providing additional dozing pipe about 10 mtr from dozing machine to delivery of bore well pipe and also if required contractor has to do one point or 5 AMP Plug point wiring required to give electric supply to machine.

(8)

Tenderer's Signature with Stamp Date:-

Add.C.E. (W.O.E&M)

33

DATA SHEE FOR CHLORINE DOSING SYSTEM


Sr. No 1 Make of chlorine Dozer Machine 2 Type Positive diaphram dosing unit 3 4 Actuator Material of diaphram Solenoid Hypalon with Teflon lining Teflon Rubber 5 6 7 8 9 10 11 Spacer Ring Seal Foot Valve Body Suction pipe Suction Valve Maximum Injecting Pressure Required 12 13 Dosing Capacity Controller 0.5 to 5 Ltr/ Hr manual Control 14 FRP Tank 100 ltr speed & Stroke Poly propylene/ GRPP Viton/ Hypalon PVC/ Nylon-6/ ABS Polypropylene Polypropylene / LDPE PVC/ Nylon-6/ ABS 5 kg / cm2 Displacement type electronic Aventura, Etatron, Panda Description Required by AMC Offered by Tenderer

Sign of Contractor Name & Tenderers Seal

Add. C.E. (W.O, E & M) Ahmedabad Municipal Corporation

34

ANNEXURE XI

Technical Specification of S ection pillar for chlorine dozer machine


(1) The Design of section pillar must be suitable housing for chlorine dosing machine having F.R.P. Tank . Sectio n pillar must be made from fabricated from 40 mm x 40 mm x 6 mm thick x 7 fit height M.S. angle. Enclosure and door must be fabricated from 2.0 mm thick CRCA sheet. Bottom of cabinet must be made from 4 mm thick M.S. Plate. Cabinet internal size must be of 32 " height x 24 " width x 24 " depth. All plate & angle should be used without joint. It must be rain water proof . Hinge of cabinet's door must be welded with angle of section pillar. One nos. of 6 lever godrej - Nav Tal lock must supply with section pillar. Light board complete with one button holder with 5 AMP. Switch and one 5 AMP. three pin plug with 5 AMP. Switch and complete with internal wiring. Section pillar must be duly painted inside and outside with one coat of Red-oxide and two coat of light gray semi glossy shade 331. On bottom of legs 3 mm thick plate of 4 " dia must be welded. Four legs of section pillar must be fitted with Tie Rods. Hinges of the door must be heavy and made form the 20 mm width x 6 mm thick strips with 8 mm hinges pin. Bottom plate of section pillar should be strengthened with two nos. of 35 mm x 35 mm x 4 mm thick M.S. angle diagonally welded below the bottom plate.

(2)

(3)

(4) (5) (6) (7) (8) (9)

(10)

(11) (12) (13)

(14)

Tenderer's Signature with Stamp Date:-

Add.C.E. (W.O.E&M)

35

36

PRICE SCHEDULE Site:(1) East Zone Odhav Vepari Mahamandal, Plot No - 51. (2) Vatva T.P. no- 88, Plot No 51/1 + 51/2 + 53/1. (3) Odhav Bahiyal Ground T.P. no- 3, Plot No 86/P. (4) Shahvadi EWS Quarter T.P. no- 94, Plot No 2/1.

Prices of the work and material must be as per tender specifications. Prices must be including excise, taxes, vat, packing and forwarding insurance, freight, loading and unloading charges etc. FOR store and / or site delivery basis.

Sr No. 1

Description Labour charges for drilling, pipe lowering, gravel packing, compressor development with 250 psi & 1000 CFM capacity Air Compressor, 125/85 HP submersible development with generator & sounding test, site clearance, verticality test & Acceptance test etc. for construction successfully new tube-well as per tender specification. 650 mm dia. Borehole for 350 mm dia pipe up to

Quantity

Unit

Rate in Rs.

Amount in Rs.

1. 2. 3. 4. 5. 6.

0 to 30 mtrs 31 to 60 mtrs 61 to 90 mtrs 91 to 120 mtrs 121 to 150 mtrs 151 to 180 mtrs

30.0 30.0 30.0 30.0 30.0 30.0

Mts. Mts. Mts. Mts. Mts. Mts.

550 mm dia. Borehole for 250 mm dia pipe up to

2 3

4 5

1. 181 to 210 mtrs 2. 211 to 240 mtrs 3. 241 to 270 mtrs 4. 271 to 300 mtrs 5. 301 to 310 mtrs Charges for Electro logging for Tube well. Charge for mud and cutting disposal by tanker day to day from the site without staging at site. Charges for cement ceiling work, if required by AMC After development by 85/125 H.P. Submersible pump sets if the tube well gets filled up with sand. Additiona l charges for removing sand from tube well for each mt. of filling.

30.0 30.0 30.0 30.0 10.0 1.0 Per bore well 1.0 50.0

Mts. Mts. Mts. Mts. Mts. L.S. one

L.S. mtr

37

350 mm. dia. M.S. ERW pipes having 170.0 minimum 7.0 mm. wall thickness with square face and chaplas confirming to IS 3589/1981 and ISI mark and with 50 mm width X 4 mm thick M.S. strip for housing joint covering. 250 mm. dia. M.S. ERW pipes having minimum 7.0 mm. wall thickness with square face and chaplas confirming to IS 3589/1981 and ISI mark and with 50 mm width X 4 mm thick M.S. strip for housing joint covering. 250 mm. dia. Johnson filtration make continuous slotted strainer pipe having minimum Tensile strength : 18 M.T. Collapsible Strength : 30 kg/Cm2 in slot opening of 1.0 mm. slot opening 1.5 mm slot opening 350 mm dia x 250 mm dia. Flexible / fixed reducer manufactured from steel casting confirming IS: 216 (1971 ) as per drawing . Cost of bail plug 250 mm. dia. X 7.00 mm minimum wall thickness X 5 mt. length with welded cone at the bottom, with 55 mm length X 1.5 mm width 2900 nos. slot in 3 mt. length of bail plug at the bottom 350 mm. dia. Well cap as per drawing. 350 mm. dia. half coupling for protection of top pipe as per drawing Housing pipes M.S. clamp, prepared from 4" x 3/4" x 24" long M.S. flat with square wooden support. Supplying, Installing, testing and commissioning of Submersible pumps
in bore well. 40.0

mts

mts

80.0 80.0 1.0

mts mts no

10

1.0

no

11 12 13

1.0 1.0 1.0

no pair set

14 a

____________ set

KSB

/LUBI/U-Neel

Submersible 1.0

pump having discharging capacity of 80

m3/Hr. at 150 Mts. Head in standard material. 2 x 3 x 25 mm2 copper PVC flat 150 300.0 mtr. cable (Total 300 mt.) with connecting flange column pipe as per tender document 6" dia. 5.4mm minimum thickness MS 140.0 double flanged ga lvenised column pipes With MS nut bolts washers & 1.5mm thick rubber gasket & upper delivery piece as per tender document Set of submersible pump-set switch, 1.0

Mtr.

Mtr.

set
38

starter, delta starter with section pillar, capacitor, earth leakage, relay, cable box, cable gland, lighting board, earthing strip, lock as per tender document 3.5 x 120 mm 2 aluminum PVC 20.0 armoud cable standard make. 150 mm dia. x 90 o CIDF short bend. 150 mm dia.CIDF sluice valve as per tender document. 150 mm dia 1.0 mt. length CIDF B class CI pipe as per tender document. 5/8 f x 3 length nut bolts (16mm x 90 mm) 5/8 f MS washer Connecting nut, bolts, washer & gasket MS boreplat in split assembley M.S. clamp for 150 mm dia column pipe M.S. bore plate for 14 dia bore and 150 mm dia column pipe 8 f one side flange bore drop piece (as per drawing) Double door L.T. service section pillar as per tender specification. 315 amp x 415 volt extra switch fuse unit for L.T. service (combination SFU not acceptable) SITC of chlorine dosing machine with F.R.P. Tank and complete accessories. Single door section pillar for chlorine dozer machine as per tender specification. Total Amount of one bore well :2.0 1.0 1.0

Mts.

f g h i j k l m n o 15 16

no no no

10 kg. 5 kg
1.0 1.0 1.0 1.0

kg kg
set no set set

1.0 1.0 1.0

no no no

17 18

1.0 1.0

no no

Rs.

Total Amount of Four bore wells :-

Rs.

Rs. In words

Tenderers Signature & Stamp

Addl.C.E. (W.O.E.& M.)