Test Plan for Ethnernet Demarcation Monitoring System

Test Object 1: VLAN


1.1 Access mode Test Item Test content
Test topology

VLAN module Access mode

Test Steps

1.Measured equipments and PCs are connected like topological; 2.Configure tested equipments as access mode on client 1, and create vlan10 Raisecom(config)#interface client 1 Raisecom(config-port)# switchport mode access Set successfully Raisecom(config)#create vlan 10 active Create successfully 3, configure tested equipments as trunk mode on line 1, allows all Vlans. Raisecom(config)#interface line 1 Raisecom(config-port)#switchport mode trunk Set successfully Raisecom(config-port)#switchport trunk allowed all Please input 'y' to confirm set allowed vlan:[y]y Set successfully 4, PC 1 and PC 2 ping each other. 5, modify the Vlan 10 to Vlan 5 on equipment 2 client 1. 6, PC 1 and PC 2 ping each other. 7, modify the Vlan 5 to Vlan 10 on equipment 2 client 1. 8, PC 1 and PC 2 ping each other. 1 At step 4PC 1 and PC 2 can ping each other 2 At step 6PC 1 and PC 2 can not ping each other 3 At step 8PC 1 and PC 2 can ping each other. OK

Anticipate d Results Test Results and

Test Item Conclusion :

VLAN module

1.2 Trunk mode Test Item Test content Test topology VLAN module Trunk mode

Test Steps

1.Measured equipments and PCs are connected like topological; 2.Configure tested equipments as access mode on client 1, and create vlan10 Raisecom(config)#interface client 1 Raisecom(config-port)# switchport mode access Set successfully Raisecom(config)#create vlan 10 active Create successfully 3, configure tested equipments as trunk mode on line 1, allows all Vlans. Raisecom(config)#interface line 1 Raisecom(config-port)#switchport mode trunk Set successfully Raisecom(config-port)#switchport trunk allowed all Please input 'y' to confirm set allowed vlan:[y]y Set successfully 4, PC 1 and PC 2 ping each other. 5, remove Vlan 10 from the allowed list of equipment 2 line 1. 6, PC 1 and PC 2 ping each other. 7, add the Vlan 10 to the allowed list of equipment 2 line 1. 8, PC 1 and PC 2 ping each other. 9, modify both equipments client 1 from Vlan 10 to Vlan 5. 10, PC 1 and PC 2 ping each other. 1, At step 4PC 1 and PC 2 can ping each other 2, At step 6PC 1 and PC 2 can not ping each other 3, At step 8PC 1 and PC 2 can ping each other;

Anticipa ted Results

Test Item Test Results and Conclusi on:

VLAN module 4, At step 10, PC 1 and PC 2 can ping each other. OK

1.3 Interconnection between different VLAN VLAN module of RC551E-4GE is strict compliance with standard protocols IEEE802.1Q, but to a certain extent, they greatly enrich and expand the practical application of the VLAN; where can pass vlan packet with different access vlan.

Test Item Test content Test topology

VLAN module vlan packet with different access vlan can pass the port

Test Steps

1. 2.

Reboot the switch, Measured equipment and test PCs are connected like topological; Command Raisecom(config)#interface line 1 Raisecom(config-port)#switchport access vlan 10 Set successfully Raisecom(config-port)#switchport access egress-allowed vlan 20 Please input 'y' to confirm set allowed vlan:[y]y Set successfully Raisecom(config-port)#interface client 1 Raisecom(config-port)#switchport access vlan 20 Set successfully Raisecom(config-port)#switchport access egress-allowed vlan 10 Please input 'y' to confirm set allowed vlan:[y]y Set successfully

Test Item

VLAN module 3. Port 1 and 2 of tester send layer-2 packets of tag10 and tag20, while line 1 and 2 of tester receive packets:

Anticipat ed Results Test Results and Conclusio n:

1. AT step 3, the test instrument line 1 and 2 can receive packets between each other, and both of the packets are turned into untag. OK

1.4 Flexible QinQ Object Content Topology: VLAN module QinQ function

Steps 1.

(Service vlan ID 50) standard QinQ, Configuration on RC551E-4GE: Raisecom(config)#create vlan 50 active Raisecom(config)#interface client 1 Raisecom(config-port)#switchport qinq dot1q-tunnel Raisecom(config-port)#switchport access vlan 50 Raisecom(config-port)#exit Raisecom(config)#int line 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#switchport trunk allowed vlan 50

And, you need to configure the PE device to cooperate with RC551E4GE: the port connected with 551 should be configured to trunk mode,

Object

VLAN module allow VLAN 50, and the native VLAN should be configured to 50. 2. flexible QinQ, configuration on RC551E-4GE : Raisecom(config)#create vlan 50 active Raisecom(config)#interface client 1 Raisecom(config-port)#switchport qinq dot1q-tunnel Raisecom(config-port)#switchport access vlan 50 Raisecom(config-port)#exit Raisecom(config)#int line 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#switchport trunk allowed vlan 50 Raisecom(config-port)#switchport vlan-mapping egress 3 translate 20 3. 4. send packet with vlan tag 5 from one PC, catch packet from the opposite, compare the vlan tag. send packet with vlan tag 3 from one PC, catch packet from the opposite, compare the vlan tag.

Anticipat ed result

1. The packets from Line 1 to PE should have a service tag VLAN 50, while the packets from Client 1 to User A/B will have only CVLAN. 2. at step 3, for packet with inner vlan tag 5, it was tagged by outer vlan 50 3. at step 4, for packet with inner vlan tag 5, it was tagged by outer vlan 20 OK

Result

Test Object 2: 802.3ah OAM


1.5 Topology

Here, we use Demarcation device as Local Device and RC551E-4GE as Remote Device.

1.6 OAM Discover Function


Object Content PreCondition Steps OAM Discover Function OAM enable/disable In default configuration, set PC1 as snmp host of Local Demarcation Device and oam event trap is enable. Print LOG_INFO at local end. 1. Enable OAM function in downlink ports of Local Demarcation Device. Local (config-port)#oam enable 2. Display OAM information in downlink ports. Local#show oam Local#show oam peer Remote#show oam Remote#show oam peer 3. Display OAM trap information in downlink ports at Local Demarcation Device. Local #show oam trap Step 2: PC receives discovery trap; Local#sho oam port-list 1-3 Port: 1 Mode: Active Administrate state: Enable Operation state: ActiveSendLocal Max OAMPDU size: 1518 Config revision: 0 Supported functions: Loopback, Event Port: 2 Mode: Active Administrate state: Enable Operation state: Operational

Anticipat ed Results

Max OAMPDU size: 1518 Config revision: 0 Supported functions: Loopback, Event Port: 3 Mode: Active Administrate state: Disable Operation state: Disabled Max OAMPDU size: 1518 Config revision: 0 Supported functions: Loopback, Event Local#sho oam peer Port: 1 Port: 2 Peer MAC address: 000E.5E55.1AAA Peer vendor OUI: 000E5E Peer vendor info: 1 Peer mode: Passive Peer max OAMPDU size: 1518 Peer config revision: 0 Peer supported functions: Loopback, Event, Variable Remote#sho oam Port: client1 Mode: Passive Administrate state: Enable Operation state: Operational Max OAMPDU size: 1518 Config revision: 0 Supported functions: Loopback, Event, Variable Port: client2 Mode: Passive Remote#sho oam peer Port: line1 Port: line2 Port: client1 Peer MAC address: 000E.5E34.2365 Peer vendor OUI: 000E5E

Peer Peer Peer Peer Peer

vendor info: 1 mode: Active max OAMPDU size: 1518 config revision: 0 supported functions: Loopback, Event

Port: client2 Step 3: Local#sho oam trap Port: 2 Event trap: Disable Peer event trap: Enable Discovery trap total: 1 Discovery trap timestamp: 0 days, 0 hours, 22 minutes Lost trap total: 0 Lost trap timestamp: 0 days, 0 hours, 0 minutes Result OK

1.7 OAM Dying Gasp


Object Content Condition OAM dying gasp indication function OAM dying gasp As Topology and in default configuration, configure PC as snmp host of Local Demarcation Device; Local Command session can print LOG_INFO syslog. 1, Check the downlink port information Local#show oam Remote# show oam 2, Enable OAM trap function in downlink port Local (config-port)#oam peer event trap enable 3, plug off the fiber between two devices 4, observe the alarm reported by command line or NMS. 5, recover the fiber connection. 6, Plug off the remote device power and check the downlink port event information: Local#show oam peer event 7, Plug in the remote device power, wait for the system restart. Enable OAM dying gasp indication: Remote (config-port)#oam notify dying-gasp enable

Steps

8, observe the alarm reported by command line or NMS. Anticipat ed Results Step 1: both two devices show OAM operation state as operational. Step 3: just link fault, no dying gasp alarm. Step 6: after 1 second, PC will receive NonThreshouldEvent notification, type as Dying gasp, Local#sho oam peer event Port: 1 Port: 2 TimeStamp: 0 days, 1 hours, 32 minutes Type:dyingGasp RunningTotal: 10 EventTotal: 10 Result

OK

1.8 OAM Critical Event


Object Content Precondition Steps 1. Set remote device high-temperature threshould lower than current temperator or low-temperature threshould higher than current temperature. (check current temperature by show hardware command) Remote(config)#alarm temperature threshold celsius low 20 high 30 Set successfully 2. Check remote device downlink port OAM event information: Local #show oam peer event 3. Set remote device high-temperature higher than current temperature, low-temperature lower than current temperature. Anticipat ed Results Result Step 1: PC receives NonThresholdNotification. Step 2: show recent events record. Step 3: PC receives OAMNormalTrap Notification. OK OAM critical event indication OAM critical event indication As Topology and in default configuration, configure PC as snmp host of Local Demarcation Device; Local Command session can print LOG_INFO syslog. oam peer event trap is enable.

1.9 OAM Loopback


Object Content Precondition Steps OAM Loopback Set loopback sucessfully. Except OAM, disable all auto packets generating functions as STP, TNDP, loopback-detection. 1. Configure Local(config-port)#oam remote-loopback 2. Check loopback state Local#show oam loopback Remote# show oam loopback 3. PC individually sends unicast, broadcast & multicast packets in rate of 100 packets/second for 2 seconds. Check the connected remote port statistics: Remote#show interface port xx statistics

Anticipat ed Results

Step 1: Local(config-port)#oam remote-loopback Set successfully Step 2: Local#sho oam loopback Port: 1 Loopback status: No Loopback react: Ignore Port: 2 Loopback status: Remote Loopback react: Ignore Remote#sho oam loopback client 1,2 Port: client1 Loopback status: Local Loopback react: Process Port: client2 Loopback status: No Loopback react: Processlocal Step 3: Related unicast, broadcast and multicast transmit/receive increasing to 200 packets.

Result

OK

1.10 Remote Event Notification


Object Pre-condition Remote event notification. As Topology and in default configuration, configure PC as snmp host of Local Demarcation Device; Local Command session can print LOG_INFO syslog. 1. Configure remote device uplink frame error threshold as 0 Remote (config-port)#oam errored-frame-period window 60000 threshold 0 Remote (config-port)#oam errored-frame window 60 threshold 0 Remote (config-port)#oam errored-frame-seconds window 120 threshold 0 2. Check OAM record Local#show oam peer event 3. Enable Remote device downlink port OAM event trap: Local (config-port)#oam peer event trap enable 4. Show Remote device port OAM event trap Local#show oam trap 5. Configure Remote device uplink OAM event trap as disable: Remote (config-port)#oam notify errored-frame-period disable Remote (config-port)#oam notify errored-frame disable Remote (config-port)#oam notify errored-frame-seconds disable 6. Repeat Step 2 Anticipated Results Step 1: PC does not receive trap. Step 2: Local#sho oam peer event Port: 1 Port: 2 TimeStamp: 0 days, 0 hours, 2 minutes Type:erroredFrame Window: 60 Threshold: 0 Value: 0

Steps

RunningTotal: 0 EventTotal: 25 TimeStamp: 0 days, 0 hours, 0 minutes Type:erroredFrame Window: 60 Threshold: 0 Value: 0 RunningTotal: 0 EventTotal: 23 TimeStamp: 0 days, 0 hours, 1 minutes Type:erroredFrame Window: 60 Threshold: 0 Value: 0 RunningTotal: 0 EventTotal: 24 Step 3: PC receives traps about ThreshouldEvent Notification periodically (1 minute). Step 4: Local#sho oam trap Port: 1 Event trap: Disable Peer event trap: Enable Discovery trap total: 0 Discovery trap timestamp: 0 days, 0 hours, 0 minutes Lost trap total: 0 Lost trap timestamp: 0 days, 0 hours, 0 minutes Port: 2 Event trap: Disable Peer event trap: Enable Discovery trap total: 1 Discovery trap timestamp: 0 days, 0 hours, 1 minutes Lost trap total: 0 Lost trap timestamp: 0 days, 0 hours, 0 minutes 5PC does not receive ThresholdEvent notification any more. 6Show the recent traps received.

IEEE802.1ag CFM, Y.1731 and inservice 2544


Features Tested: IEEE802.1ag CFM functions (Traceroute, Loopback, and Fault Detection)

Configuration s

Connect RC551E-4GE 1 Line 1 to switch 1 via a fiber; Make sure Switch 1 & 2 are both in the Core network and can PING each other Connect RC551E-4GE 2 Line 1 to the Switch 2 via a fiber; Connect laptop serial port to RC551E-4GE 1 console port.

RC551E-4GE 1 pre-configuration: Set up IP address in VLAN 1: RC551E-4GE1#config RC551E-4GE1(config)#ip address 192.168.6.1 1 Set successfully Set up the CFM domain name as md7 in priority level 7 & service name as ma10: RC551E-4GE1(config)#ethernet cfm domain md-name md7 level 7 Set successfully RC551E-4GE1(config)#service ma10 level 7 Set successfully RC551E-4GE1(config-service)#exit Create a VLAN 10 as CFM service VLAN: RC551E-4GE1(config)#create vlan 10 active Create successfully RC551E-4GE1(config)#int clien 1

RC551E-4GE1(config-port)#switchport access vlan 10 Set successfully RC551E-4GE1(config-port)#exit RC551E-4GE1(config)#service ma10 level 7 Enable VLAN in CFM service: RC551E-4GE1(config-service)#service vlan-list 10 Set successfully Set up MEP in RC551E-4GE Client 1: RC551E-4GE1(config-service)#service mep up mpid 1 client 1 Set successfully Enable all MEP in CFM connectivity check function: RC551E-4GE1(config-service)#service cc enable mep all Set successfully Enable RC551E-4GE MEP learning ability to learn other MEPs RC551E-4GE1(config-service)# service remote-mep learning active Set successfully RC551E-4GE1(config-service)#exit Enable CFM function: RC551E-4GE1(config)#ethernet cfm enable Set successfully Set up MIP in Line 1: RC551E-4GE1(config-port)#interface line 1 RC551E-4GE1(config-port)#switchport mode trunk Set successfully RC551E-4GE1(config-port)#ethernet cfm mip level 7 Set successfully RC551E-4GE1(config-port)#exit RC551E-4GE1(config)#exit RC551E-4GE1#sho run System current configuration: !ROS Version ROS_4.9.868.RC551E_GE.2.20090818 !command in view_mode ! !command in config_mode first-step

create vlan 10 active ethernet cfm domain md-name md7 level 7 ! !command in aclmap_mode ! !command in enable_mode ! !command in region_mode ! !command in ip igmp profile mode ! !command in service_mode service ma10 level 7 service vlan-list 10service mep up mpid 1 client 1 service cc enable mep 1 ! !Command in vlan_group_mode ! !command in port_mode ! interface line 1 sfp type fiber1000 switchport mode trunk speed 1000 duplex full ethernet cfm mip level 7 ! interface client 1 switchport access vlan 10 ! !command in vlan configuration mode ! !command in ip interface mode ! !command in ospf_mode ! !command in rip_mode ! !command in cluster_mode ! !command in cmap_mode ! !command in pmap_mode

! !command in config_mode ip address 192.168.6.1 255.255.255.0 1 line 1 client 1 ethernet cfm enable !

RC551E-4GE 2 pre-configuration: Same as RC551E-4GE 1 configuration with variations as highlighted below Set up IP address in VLAN 1: RC551E-4GE2#config RC551E-4GE2(config)#ip address 192.168.6.4 1 Set successfully Set up the CFM domain name as md7 in priority level 7 & service name as ma10: RC551E-4GE2(config)#ethernet cfm domain md-name md7 level 7 Set successfully RC551E-4GE2(config)#service ma10 level 7 Set successfully RC551E-4GE2(config-service)#exit Create a VLAN 10 as CFM service VLAN: RC551E-4GE2(config)#create vlan 10 active Create successfully RC551E-4GE2(config)#int clien 1 RC551E-4GE2(config-port)#switchport access vlan 10 Set successfully RC551E-4GE2(config-port)#exit RC551E-4GE2(config)#service ma10 level 7 Enable VLAN in CFM service: RC551E-4GE2(config-service)#service vlan-list 10 Set successfully Set up MEP in RC551E-4GE Client 1: RC551E-4GE2(config-service)#service mep up mpid 4 client 1 Set successfully

Enable all MEP in CFM connectivity check function: RC551E-4GE2(config-service)#service cc enable mep 4 Set successfully Enable RC551E-4GE MEP learning ability to learn other MEPs RC551E-4GE2(config-service)# service remote-mep learning active Set successfully RC551E-4GE2(config-service)#exit Enable CFM function: RC551E-4GE2(config)#ethernet cfm enable Set successfully Set up MIP in Line 1: RC551E-4GE2(config-port)#interface line 1 RC551E-4GE2(config-port)#switchport mode trunk Set successfully RC551E-4GE2(config-port)#ethernet cfm mip level 7 Set successfully RC551E-4GE2(config-port)#exit RC551E-4GE2(config)#exit RC551E-4GE2#sho run System current configuration: !ROS Version ROS_4.9.868.RC551E_GE.2.20090818 !command in view_mode ! !command in config_mode first-step create vlan 10 active ethernet cfm domain md-name md7 level 7 ! !command in aclmap_mode ! !command in enable_mode ! !command in region_mode ! !command in ip igmp profile mode ! !command in service_mode

service ma10 level 7 service vlan-list 10 service mep up mpid 4 client 1 service cc enable mep 4 ! !Command in vlan_group_mode ! !command in port_mode ! interface line 1 switchport mode trunk ethernet cfm mip level 7 ! interface client 1 switchport access vlan 10 ! !command in vlan configuration mode ! !command in ip interface mode ! !command in ospf_mode ! !command in rip_mode ! !command in cluster_mode ! !command in cmap_mode ! !command in pmap_mode ! !command in config_mode ip address 192.168.6.4 255.255.255.0 1 line 1 client 1 ethernet cfm enable !

Display remote MEP information: Show remote MEP on RC551E-4GE 1: RC551E-4GE1# sh ethernet cfm remote-mep Maintenance Domain(MD) level:7 Maintenance Domain(MD) name: md7 Mpid Service Primary Vlan IfState PortState Mac Address Source Age

------------------------------------------------------------------------------------4 ma10 10 Down Up 000E.5E7F.D25A 1 0 Show remote MEP on RC551E-4GE 2: RC551E-4GE2#sho ethernet cfm remote-mep Maintenance Domain(MD) level:7 Maintenance Domain(MD) name: md7 Mpid Service Primary Vlan IfState PortState Mac Address Source Age ------------------------------------------------------------------------------------1 ma10 10 Down Up 000E.5E71.AF25 4 9

PING/Loopback: RC551E-4GE1#con Configuration mode, one command input per times. End with CTRL-Z. CONFIG-I:Configured from console ... RC551E-4GE1(config)#service ma10 level 7 RC551E-4GE1(config-service)#ping mep 4 Sending 5 Ethernet CFM loopback messages to 000e.5e7f.d25a, timeout is 2.5 seconds: !!!!! Success rate is 100 percent (5/5). Ping statistics from 000e.5e7f.d25a: Received loopback replys<5 /0 /0 > (In order/Out of order/Error) Traceroute: RC551E-4GE1(config-service)#traceroute mep 4 TTL: <64> Tracing the route to 000e.5e7f.d25a on level 7, service ma10. Traceroute send via port 2. ---------------------------------------------------------------------------------Hops HostMac Ingress/EgressPort IsForwarded RelayAction NextHop ---------------------------------------------------------------------------------1 000e.5e71.af25 C:1/L:1 Yes rlyFdb !2 000e.5e55.1aaa L:1/No rlyHit

Throughput test: RC551E-4GE1(config-service)#test throughput object Expected band-wide(2Mbps-900Mbps) RC551E-4GE1(config-service)#test throughput object <2-900> Band-wide(unit:Mbps) RC551E-4GE1(config-service)#test throughput object 5 y.1731 throughput test information: Maintenance Domain Level: 7 Service Instance: ma10 Time out: 5 second Throughput testing between MEP 1 in port C: 1 and remote MEP 4 start! Press <ctrl+c> to skip, throughput test will run in the background. y.1731 throughput test result: Successed Far End throughput test result: Local Send(bps) Remote Recv(bps) Local Send(pps) Remote Recv(pps) --------------------------------------------------------------------------5,000,000 4,968,000 2,248 2,258 Near End throughput test result: Remote Send(bps) Local Recv(bps) Remote Send(pps) Local Recv(pps) --------------------------------------------------------------------------5,000,000 4,968,000 2,257 2,261 Delay,Delay jitter,packet loss test: Configure performance monitor: RC551E-4GE2(config-service)# service performance-monitor enable RC551E-4GE2(config-service)# service performance-monitor enable remote-mep 1 RC551E-4GE1(config-service)# service performance-monitor enable RC551E-4GE1(config-service)# service performance-monitor enable remote-mep 4

Display: RC551E-4GE1# sho ethernet cfm performance-monitor result Maintenance Domain(MD): 1 Service Instance : 1 Performance monitor to remote MEP 2 : -----------------------------------------------------------------------Operation <1>: Schedule Status: Active Number of Send Test: 5 Number of Successful Test: 5 Percent of Drop Pkts: 0.00% -----------------------------------------------------------------------Info of Successful Test TWO-WAY ONE-WAY(SD) ONEWAY(DS) -----------------------------------------------------------------------Delay Min(msec) : 1 1 1 Delay Max(msec) : 4 2 2 Delay Sum(msec) : 12 7 7 Delay Sum2(msec) : 36 11 11 Jitter Sum(msec) : 5 1 1

RC551E-4GE1# sho ethernet cfm performance-monitor statistic Maintenance Domain(MD): 1 Service Instance : 1 Performance monitor to remote MEP 2: -----------------------------------------------------------------------Operation <1>: StartTime: 0 days, 0 : 25 : 31 Schedule Life(sec): forever Schedule Period(sec): 20 Number of Send Test: 65 Number of Successful Test: 65 Percent of Drop Pkts: 0.00% -----------------------------------------------------------------------Statistic of Schedule : TWO-WAY ONE-WAY(SD) ONEWAY(DS) -----------------------------------------------------------------------Delay Min(msec) : 1 1 1 Delay Max(msec) : 5 2 2 Delay Sum(msec) : 99 68 68

Delay Sum2L(msec) : 203 76 Delay Sum2H(msec) : 0 0 Jitter Sum(msec) : 44 5 RC551E-4GE 1 & 2 final configuration: RC551E-4GE1(config-service)#sho run

76 0 5

System current configuration: !ROS Version ROS_4.9.868.RC551E_GE.2.20090818 !command in view_mode ! !command in config_mode first-step create vlan 10 active ethernet cfm domain md-name md7 level 7 ! !command in aclmap_mode ! !command in enable_mode ! !command in region_mode ! !command in ip igmp profile mode ! !command in service_mode service ma10 level 7 service vlan-list 10 service remote-mep 4 service mep up mpid 1 client 1 service cc enable mep 1 ! !Command in vlan_group_mode ! !command in port_mode ! interface line 1 sfp type fiber1000 switchport mode trunk speed 1000 duplex full ethernet cfm mip level 7 ! interface client 1 switchport access vlan 10 !

!command in vlan configuration mode ! !command in ip interface mode ! !command in ospf_mode ! !command in rip_mode ! !command in cluster_mode ! !command in cmap_mode ! !command in pmap_mode ! !command in config_mode ip address 192.168.6.1 255.255.255.0 1 line 1 client 1 ethernet cfm enable ! RCE-4GE2(config-service)#sho run System current configuration: !ROS Version ROS_4.9.868.RC551E_GE.2.20090818 !command in view_mode ! !command in config_mode first-step create vlan 10 active ethernet cfm domain md-name md7 level 7 ! !command in aclmap_mode ! !command in enable_mode ! !command in region_mode ! !command in ip igmp profile mode ! !command in service_mode service ma10 level 7 service vlan-list 10 service remote-mep 1 service mep up mpid 4 client 1 service cc enable mep 4

! !Command in vlan_group_mode ! !command in port_mode ! interface line 1 sfp type fiber1000 switchport mode trunk speed 1000 duplex full ethernet cfm mip level 7 ! interface client 1 switchport access vlan 10 ! !command in vlan configuration mode ! !command in ip interface mode ! !command in ospf_mode ! !command in rip_mode ! !command in cluster_mode ! !command in cmap_mode ! !command in pmap_mode ! !command in config_mode ip address 192.168.6.4 255.255.255.0 1 line 1 client 1 ethernet cfm enable ! Test Results This test is to demonstrate that RC551E-4GEs compliance with IEEE802.1ag CFMs & Y.1731 performance measurements. 1. The RC551E-4GE is able to find & display remote MEP description successfully. 2. The RC551E-4GE is able to trace the network routes with descriptions successfully. 3. The RC551E-4GE is able to achieve IEEE802.1ag CFM PING/loopback successfully. 4. The RC551E-4GE is able to test the Y .1731(RFC2544) built-in throughput

successfully. 5. The RC551E-4GE is able to test the Y .1731 delay, delay jitter & packet loss successfully.

QoS
1.11 SP schedule mode Test Object Content Topology QoS SP schedule mode

Precondition Steps

Stream 1&2&3 goes into RC551E-4GE client 1; RC551E-4GE connects PE device with line 1. 1. Configure RC551E-4GE 1 QoS mode to SP Raisecom(config)#mls qos enable Raisecom(config)#interface client 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#exit Raisecom(config)#interface line 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#exit Raisecom(config)#mls qos queue scheduler sp Raisecom(config)#mls qos trust cos 2. Configure strategy Raisecom(config)#class-map v10 match-any Raisecom(config-cmap)#match vlan 10 Raisecom(config-cmap)#exit Raisecom(config)#class-map v20 match-any Raisecom(config-cmap)#match vlan 20 Raisecom(config-cmap)#exit Raisecom(config)#class-map v30 match-any Raisecom(config-cmap)#match vlan 30 Raisecom(config-cmap)#exit Raisecom(config)#policy-map aaa Raisecom(config-pmap)#class-map v10 Raisecom(config-pmap-c)#set cos 1 Raisecom(config-pmap-c)#exit Raisecom(config-pmap)#class-map v20

Raisecom(config-pmap-c)#set cos 2 Raisecom(config-pmap-c)#exit Raisecom(config-pmap)#class-map v30 Raisecom(config-pmap-c)#set cos 3 Raisecom(config-pmap-c)#exit Raisecom(config-pmap)#exit Raisecom(config)#service-policy bbb ingress client 1 Anticipated Result Result Only stream 3 will be received from the other end.

1.12 WRR schedule mode Test Object Content Topology QoS WRR schedule mode

Precondition Steps

Stream 1&2&3 goes into RC551E-4GE client 1; RC551E-4GE connect PE device with line 1. 1. Configure RC551E-4GE 1 QoS mode to SP Raisecom(config)#mls qos enable Raisecom(config)#interface client 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#exit Raisecom(config)#interface line 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#exit Raisecom(config)#mls qos queue scheduler wrr Raisecom(config)#mls qos queue wrr 1 3 5 7 Raisecom(config)#mls qos mapping cos 1 to localpriority 1 Raisecom(config)#mls qos mapping cos 2 to localpriority 2 Raisecom(config)#mls qos mapping cos 3 to localpriority 3 Use show mls qos mapping cos and show mls qos mapping localpriority to see the mapping information.

2. Configure strategy This part is same to 4.1 step2 strategy configuration. Anticipated Result Result Besides QoS, you can use the command below to do rate limit and realize quality assurance: Raisecom(config)#rate-limit vlan 10 200 50 Stream 1&2&3 ratio: 1:3:5

Dual-Stack
Object Content Topology Dual-Stack User-network diagnostics mode.

Stream 1&2&3 go into RC551E-4GE client 1 and line 1 Steps 1. Set 551 client side allow only VLAN 10, line side allow only VLAN 20. Raisecom(config)#user-network diagnostics Raisecom(config-usrnet)#diagnose client 1 send-tag 8100 10 1 Raisecom(config-usrnet)#diagnose line 1 receive-tag 8100 20 Raisecom(config-usrnet)#exit save-diagconfig 2. Set related port to trunk mode Raisecom(config)#create vlan 10,20,30 active Raisecom(config)#interface client 1 Raisecom(config-port)#switchport mode trunk Raisecom(config-port)#exit Raisecom(config)#int line 1 Raisecom(config-port)#switport mode trunk 3. Configure mirror port for data monitoring Raisecom(config)#mirror enable Raisecom(config)#mirror source-port-list ingress client 1 Raisecom(config)#mirror monitor-port client 2 Check the packets VLAN Tag on client 2. 4. Change mirror source port to line 1 Raisecom(config)#mirror enable Raisecom(config)#mirror source-port-list ingress line 1 Raisecom(config)#mirror monitor-port client 2 Check the packets VLAN Tag on client 2. Step 3, only packets with VLAN tag 10 can be received. Step 4, only packets with VLAN tag 20 can be received

Anticipat ed result Result

Network Management
Object Content Topology Network management Show NMS operation and ability on information collection N/A

Steps

1. Install Nview software on PC. Ref. Raisecom NMS user manual for detailed installation guide. 2. Install RC551E-4GE EMS on PC. Ref. related EMS user manual for more info. Connect 551E-4GE with PC and find it on Nview system. 3. Show RC551E-4GE operation windows on NMS platform, like:

4. Show RC551E-4GE information display page, like

Result

7 .Rate limit Test Item Test content Rate Limit Rate Limit

Test Item
Test topology

Rate Limit

Test Steps

1.Measured equipments and PCs are connected like topological; 2.Configure tested equipments as access mode on client 1, and create vlan10 Raisecom(config)#interface client 1 Raisecom(config-port)# switchport mode access Set successfully Raisecom(config)#create vlan 10 active Create successfully 3, configure tested equipments as trunk mode on line 1, allows all Vlans. Raisecom(config)#interface line 1 Raisecom(config-port)#switchport mode trunk Set successfully Raisecom(config-port)#switchport trunk allowed all Please input 'y' to confirm set allowed vlan:[y]y Set successfully 4, PC 1 and PC 2 ping each other. 5, config rate limit as 1Mbps. Raisecom(config)#rate-limit client 1 egress 1024 6, PC 1 download a file from PC 2 by Http. 7, config rate litmit as 64kbps. Raisecom(config)#rate-limit client 1 egress 64 8, PC 1 download a file from PC 2 by Http 1, At step 4PC 1 and PC 2 can ping each other 2, At step 6the download speed should around 125KB/s 3,At step 8the download speed should around 8KB/s. OK

Anticipate d Results Test Results and Conclusion :