Prmyslov podlahov ntry TECNOFLOOR jsou ureny do nejnronjch podmnek s astm a intenzivnm pouitm. Zaten a namhn, kterm jsou odoln podlahy kad den vystaveny, v kombinaci s bezpenostnmi, zdravotnmi a hygienickmi normami, kter musej plnit, ns motivovaly k zahjen dlouhodobho vzkumu, na jeho zklad jsme vyvinuli tuto adu podlahovch een idelnch pro kad pouit vyadujc trvanlivou, odolnou a vizuln zajmavou povrchovou pravu. Mezi konkrtn pouit pat:
PRMYSL A PODNIKN | vroba | distribuce | sklady | spolen prostory | toalety | zvody na vrobu potravin | restaurace | kuchyn | jdelny | BYDLEN | gare | suterny | kuchyn | terasy a verandy | chodnky | umvrny | tlocviny | PRODEJNY | vstavn a prodejn prostory | prostory s hustm vskytem idi vozidel, vysokozdvinch vozk nebo dopravnch vozidel | prostory s prodejnmi automaty | opravrensk prostory | sklady | chodnky | terasy | leteck hangry | muzea | televizn studia | prostory s vskytem zvat | VEEJN INSTITUCE | porn stanice | istiky odpadnch vod | parky a rekrean oblasti | policejn stanice | npravn stavy | vzdlvac centra | uebny | bufety | pevlkac kabiny | muzea | vstavn haly | PRODEJ A SERVIS AUTOMOBIL | prodejci automobil | servisy pro vmnu oleje | myky automobil | opravny vozidel | maloobchodn prodejny | parkovit | prostory pro servis fleetovch vozidel
EPOXY FLOORS
TECNOFLOOR Tw-3040
Water-based epoxy coating
TECNOFLOOR Tw-3040 is a fluid, pigmented, waterbased epoxy coating with optimal chemical and mechanical resistance properties. It has been especially designed for application in garages, parking lots, and vehicle transit areas, over flooring surfaces subject to the strictest decontamination and cleaning standards, and in the chemical and food processing industries.
Paint Ntr
RAL 3016
RAL 6001
RAL 7042
Pednosti
Rozpustnost ve vod. Vysoce tekut vrobek s rychlou a snadnou aplikac. Rozmanitost povrchovch prav lze pout ve vce vrstvch nebo k natrn. Snadn drba, itn a dekontaminace. Optimln chemick odolnost. Vynikajc kryc schopnost. Optimln pilnut k betonu. Umouje difuzi vodn pry. Vhodn pro aplikaci na podkladov povrchy vykazujc uritou mru vlhkosti.
Highly-fluid product, quick and easy to apply. Finishing versatility, it can be used for multilayer, or painting purposes. Easy to maintain, clean and decontaminate. Optimal chemical resistance. High coating capability. Optimal adherence to concrete. Allows water vapor diffusion. Suitable for application on underlayment surfaces with a certain level of humidity.
TECNOFLOOR T-3020
Epoxidov ntr 100% obsah pevnch ltek
TECNOFLOOR T-3020 je pigmentovan, tekut, vysoce chemicky a mechanicky odoln epoxidov ntr tvoen ze 100% z pevnch ltek uren pro aplikaci na betonov podlahov povrchy. Byl vyvinut speciln pro pouit jako ochrann ntr nanen na betonov povrchy a jako odoln vrchn vrstva prmyslovch podlah.
Paint Ntr
5
Self-Leveling Samonivelan vrstva
RAL 3016
RAL 6001
RAL 7042
Pednosti
100% obsah pevnch ltek. Bez rozpoutdel a bez zpachu. Vysoce tekut vrobek s rychlou a snadnou aplikac. Rozmanitost povrchovch prav lze pout k samonivelaci, nanesen vce vrstev nebo k natrn. Snadn drba, itn a dekontaminace. Optimln chemick odolnost. Vynikajc povrchov vlastnosti. Optimln pilnut k betonu. Monost vroby podle tabulky barev RAL
Highly-fluid product, quick and easy to apply. Finishing versatility, it can be used for selfleveling, multilayer, or painting purposes. Easy to maintain, clean and decontaminate. Optimal chemical resistance. High coating power. Optimal adherence to concrete. Possibility to produce according to RAL color chart.
EPOXY FLOORS
TECNOFLOOR T-3020
Epoxy 100% solids with antistatic properties
With the same basis as TECNOFLOOR T-3020, we have modified its formulation to develop a continual flooring solution that, thanks to its zero-electric charge retention properties, is suitable for environments where these are an essential requirement. It is ideal for application in areas such as electronic laboratories, white rooms, surgery rooms, offices with sensible technologies, production lines, etc...
RAL 3016
RAL 6001
RAL 7042
In combination with an earth connection, this graphite-fiber rich formula is perfect for rendering antistatic surfaces. V kombinaci se zemnicm pipojenm je tento ntr s obsahem grafitovho vlkna ideln pro vytvoen antistatickho povrchu.
Comparative|Srovnn
Paint Ntr
Water based epoxy coating Epoxidov ntr rozpustn ve vod 100% solids epoxy coating Epoxidov ntr se 100% obsahem pevnch ltek Antistatic 100% solids coating Epoxidov ntr se 100% obsahem pevnch ltek s antistatickmi vlastnostmi
Self-Leveling Samonivelace
-
TECNOFLOOR Tw-3040
TECNOFLOOR T-3020
optional | voliteln
TECNOFLOOR T-3020 AS
optional | voliteln
S: shore | pmosk
E: economy | ekonomick
A: anti-slip | protiskluzov
Finishes|Povrchov prava
Painting Application Aplikace ntru Multilayer Application Aplikace vce vrstev
7
EPOXY FLOORS
The underlayment surface must always be subject to a mechanical preparatory process: sandblasting, milling, or shot-blasting (see table in this page). Existing cracks, cavities or flaws, if any, must be filled and compacted previously, using repair mortar prepared with a combination of our PRIMER EP-1020 with 0.3 ~ 0.5 aggregate or calcium carbonate (1:1). This mixture ensures a high-strength quick-drying solution. Please contact our technical department to clarify any doubts you may have regarding before using the product. We are looking forward to help you.
TECNOFLOOR Tw-3040
P& NP P
All | Vechny Self-Leveling | Samonivelace Paint, multilayer or multilayer plus | Nater, vce vrstev nebo vce vrstev plus All | Todas Self-Leveling | Autonivelante Self-Leveling | Autonivelante
100% solids epoxy coating Epoxidov ntr se 100% obsahem pevnch ltek
TECNOFLOOR T-3020
NP
Antistatic 100% solids coating Epoxidov ntr se 100% obsahem pevnch ltek s antistatickmi vlastnostmi
TECNOFLOOR T-3020 AS
NP
Application of our priming products (see table in this page) is required for sealing purposes, to ensure proper bonding with the underlayment surface, and, therefore, a good anchoring and the proper surface finishing. The primer layer can be applied using a brush, roller or airlesstype unit. In the case of concrete surfaces, it will be necessary to allow a 28-day curation process after pouring. Otherwise, it will be necessary to check the maximum admissible humidity level on the underlayment service (specified in the products technical sheet).
TECNOFLOOR Tw-3040
P& NP P NP P NP
All | Vechny All | Vechny All | Vechny Self-Leveling | Samonivelace Self-Leveling | Samonivelace
TECNOFLOOR T-3020
TECNOFLOOR T-3020 AS
EPOXY FLOORS
3 A
Upon completing the underlayment surfaces preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, proceed to apply as many TECNOFLOOR layers as you see fit, in accordance with the level of resistance you wish to achieve. Apply at least 2 layers of product, allowing a 24 h interval between them. For optimal finishing and in order to ensure an even surface spread and protection, apply layers perpendicularly to one another.
10
3 B
Upon completing the underlayment surfaces preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, apply a first TECNOFLOOR layer. Immediately afterwards, and while the product is still wet (very important), sprinkle a layer of aggregate until saturated. Allow 24 hours and then sweep excess product, sandblast and, once again, sweep or vacuum surface to remove any leftover dust. Apply a final TECNOFLOOR layer, covering the surface completely. Repeat process as many times as required to achieve the desired strength.
11
EPOXY FLOORS
3 C
Upon completing the underlayment surfaces preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, apply a first TECNOFLOOR layer. While the product is still humid (very important), light sprinkle a layer of 0.3~1.3 aggregate and allow sufficient time for it to dry out. Once dry, sweep excess materials. Using a flat trowel, apply a new layer of TECNOFLOOR, this time mixed with aggregate 0.1 ~ 0.3 in proportion 1:1. While this last surface is still humid, light sprinkle another layer of 0.3~1.3 aggregate and let it dry out. Once dry, sweep loose aggregate, and sandblast surface. Vacuum dust resulting from sandblasting operation. Using a squeegee, spread a layer of TECNOFLOOR TW3040 diluted with 5% water or TECNOFLOOR T-3020 diluted with 5% DESMOPOL SOLVENT according to the system used. Steps in color can be repeated as many times as required, based on target thickness and resistance.
12
3 D
Upon completing the underlayment surfaces preparation process, and once the primer layer is dry (see technical sheet of the product), apply a TECNOFLOOR layer using a notched trowel. Make sure that layer thickness meets intended use requirements (recommended minimum thickness 2mm). It is essential to use a mechanical stirrer at low speed for mixing components A and B before use using, to prevent air bubble formation in the mixture, making sure to mix along the inner perimeter of the drums base thoroughly. Another possibility is to mix the product with 0.3 ~ 0.5 aggregate in 1:1 proportion and stir with mechanical stirrer at low speed. 20 minutes after applying TECNOFLOOR T-3020 it will be necessary to roll porcupine roller over surface to release trapped air. Outdoor Finishing: In outdoor applications, once the product is dry, apply a final layer of your TECNOTOPrange aliphatic enamel of choice. Anti-Slip Finishing: For Anti-Slip finishings, apply, once the product layer is dry, a final layer of our TECNOTOP range aliphatic enamel of choice mixed with a TECNOPLASTIC range micronized plastic (8% recommended) according UNE-EN 12633:2003 (Rd=3).
13
povrchov pravy aplikujte po zaschnut jedn vrstvy vrobku finln vrstvu alifatickho krycho laku ady TECNOTOP dle sv volby ve smsi s mikronizovanou umlou hmotou ady TECNOPLASTIC (doporuujeme 8 %).
EPOXY FLOORS
UNE-EN 1504.2
1,3 g/cm3 70% 1500 cps 90 minutes | zpis 45 minutes | zpis 5 ~ 7 hours | hodiny 7 days | dny 24 hours | hodiny >75 >2 MPa Min. 8 C ~ Max. 30 C Min. -20 C ~ Max. 80 C A2FLS1 SD > 50m CLASS I: SD < 5 m (permeable) | Tda I: Sd <5 m (propustn) w < 0,1 Kg/m2 X 0,5 R Mass loss = 262 mg Hmotnostn ztrta = 262 mg According CLASS I : 3 days without pressure (see results) Podle CLASS I: 3 dny bez tlaku (viz vsledky) Without cracks and flaking. Mass of 1,000 g and 2,000 g. dn praskn nebo odlupovn hmotnost 1000g a 2000g.
14
Surface temperature / environmental Temperature Resistance Reaction to fire (UNE-EN 135011:2002) Carbon dioxide permeability determination (UNE-EN 1062-6:2003) Water vapor permeability determination. Capsule method (UNEEN ISO 7783:2012)
Liquid water permeability determination Uren prostupnosti tekut vody (UNE-EN 10623:2008) (UNE-EN 1062-3:2008) Determination abrasion resistance. TABER abrasion test apparatus (UNEEN ISO 5470-1:1959) Resistance against strong chemical aggression (UNE-EN 13529:2005) Quick buckling tests (resistance to impact). Drop weight test with large surface striker (UNE-EN-ISO 62721:2004)
Uren odolnosti proti abrazi. Pstroj k testovn abraze TABER (UNE-EN ISO 5470-1:1959) Odolnost proti siln agresivnm chemickm ltkm (UNE-EN 13529:2005)
Rychl zkouky vzprem (odolnost proti nrazu). Zkouka padajcm zvam s velkoplonm kladivem (UNE 6272-1:2004)
1,65 g/cm3 100% 800 cps 90 minutes | zpis 40 minutes | zpis 6 ~ 8 hours | hodiny 7 days | dny 24 hours | hodiny >80 >2 MPa Min. 8 C ~ Max. 30 C Min. -20 C ~ Max. 80 C A2FLS1 SD < 50m CLASS III | CLASE III w < 0,1 Kg/m2 X 0,5 R AR1 Acording CLASS I : 3 days without pressure Podle CLASS I: 3 dny bez tlaku IR > 4
Surface temperature / environmental Temperature Resistance Reaction to fire (UNE-EN 135011:2002) Carbon dioxide permeability determination (UNE-EN 1062-6:2003) Water vapor permeability determination. Capsule method (UNEEN ISO 7783:2012)
15
Liquid water permeability determination Uren prostupnosti tekut vody (UNE-EN 10623:2008) (UNE-EN 1062-3:2008) Determination abrasion resistance. TABER abrasion test apparatus (UNEEN ISO 5470-1:1959) Resistance against strong chemical aggression (UNE-EN 13529:2005) Quick buckling tests (resistance to impact). Drop weight test with large surface striker (UNE-EN-ISO 62721:2004)
Uren odolnosti proti abrazi. Pstroj k testovn abraze TABER (UNE-EN ISO 5470-1:1959) Odolnost proti siln agresivnm chemickm ltkm (UNE-EN 13529:2005) Rychl zkouky vzprem (odolnost proti nrazu). Zkouka padajcm zvam s velkoplonm kladivem (UNE 6272-1:2004)