Vous êtes sur la page 1sur 16

Pexgol Installation Guidelines for Infrastructure pipelines

Pexgol Installation Guidelines for Infrastructure pipelines

Single House Inlet

Transition Elbows Plasson 492504 Plasson 493504 Plasson 494504 Plasson 4945M4 Frialen WUN 90

Pexgol 32 - 63

EF 90 Elbow Plasson 490504 Frialen W90

Pex

2 ol 3

-6

Pe

xg

ol

90

EF Coupler Plasson 490104 Frialen WN


-2 25

EF Branch Saddle PLasson 495804 63/75/90/110/160 with outlet sizes 32/ 40/50/63 200/225 with outlet sizes 63 and 90 For Diameters above 225mm use Tee Connector

Pexgol Installation Guidelines for Infrastructure pipelines

Duplex (double - house) inlet


EF Couplers 32 to 63mm

Transition Elbows Plasson 492504 Plasson 493504 Plasson 494504 Plasson 4945M4 Frialen WUN 90

Meter

PVC 110 Conduit Pipe with Concrete inside

Pexgol

x Pe

go

EF 90 Elbow Plasson 490504 Frialen W90


go l

x Pe

EF Coupler Plasson 490104 Frialen WN


Pe xg ol

Spigot Reducer PLasson 491107 EF Reducing Tee PLasson 491404

Pe

xg

ol

90

-2

25

EF Branch Saddle PLasson 495804 63/75/90/110/160 with outlet sizes 32/ 40/50/63 200/225 with outlet sizes 63 and 90 For Diameters above 225mm use Tee Connector

Pexgol

Pexgol Installation Guidelines for Infrastructure pipelines

Two-House Inlet Duplex (double - house) inlet

Meter Mechanical Transition Elbow PLasson 071506 PVC 110 Conduit Pipe with Concrete inside

EF 90 Elbow PLasson 490504 Frialen - W90

Pexgol

x Pe

go

Pe

xg

ol

EF Coupler Plasson 490104 Frialen WN


Pe xg ol

Spigot Reducer PLasson 491107 EF Reducing Tee PLasson 491404

Pe

xg

ol

90

-2

25

EF Branch Saddle PLasson 495804 63/75/90/110/160 with outlet sizes 32/ 40/50/63 200/225 with outlet sizes 63 and 90 For Diameters above 225mm use Tee Connectors

Pexgol

Pexgol Installation Guidelines for Infrastructure pipelines

Duplex (double - house) inlet

Meter Plasson 2 Outlet Manifold Kit Cat No. 078126050007 The Valves and Meters are not Applied by Plasson

go Pex

l5

Pe

xg

ol

90

EF Coupler Plasson 490104 Frialen WN


-2 25

EF Branch Saddle PLasson 495804 63/75/90/110/160 with outlet sizes 32/ 40/50/63 200/225 with outlet sizes 63 and 90 For Diameters above 225mm use Tee Connector

Pexgol 50

EF 90 Elbow Plasson 490504 Frialen W90

Pexgol Installation Guidelines for Infrastructure pipelines

90mm (3) Inlet to Apartment Blocks


Flange Adaptors 3/80 Plasson 49020 Flange Adaptor Plasson 09903 Flange Backing Ring According to DIN 2501 Frialen - EFL According to DIN 2501 Also Available: Pexgol Stub End & Steel Flange - According to any required flange standard! EF 90 Elbow 90mm Plasson 490504 Frialen W90

Pexgol 90mm

Pe

o xg

l9

EF Coupler Plasson 490104 Frialen WN


xg ol EF Branch Saddle 11 0 PLasson 495804 -2 25 63/75/90/110/160 with outlet sizes 32/ 40/50/63 200/225 with outlet sizes 63 and 90 For Diameters above 225mm use Tee Connector Pe

Pexgol Installation Guidelines for Infrastructure pipelines

Reducing Tee up to 250mm


mm

Pe

xg

ol

0 25

EF Reducing Tee PLasson 491404

Pe

xg

ol

25

0m

11-1

EF Coupler Plasson 490104 Frialen WN

Equal Tee up to 250mm


5 l2 0m m

Pe

xg

EF Tee 90 up to 250mm PLasson 491404 Frialen - TA (kit) up to 63mm For bigger sizes see Frialen Tee pieces

Pe

xg

ol

25

0m

m
EF Coupler Plasson 490104 Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Frialen Equal Tee Pieces


From 75mm up to 225mm

Pe

Pe
Frialen - TA (kit) up to 63mm For bigger sizes see Frialen Tee pieces

xg ol 2

xg

ol

50

25

0m

Pexgol Installation Guidelines for Infrastructure pipelines

Reducing Tee above 280mm


Reducing Spigot Tee Plasson 461407/491407

EF Coupler Plasson 490104 Frialen WN

EF Coupler Plasson 490104 Frialen WN

Pe

xg

ol

28

0m

Reducing Spigot Tee Plasson 461407/491407

Equal Tee above 280mm


Spigot Tee Plasson 460407/490407

EF Coupler Plasson 490104 Frialen WN EF Coupler Plasson 490104 Frialen WN

Pe

xg

ol

28

0m

Pexgol Installation Guidelines for Infrastructure pipelines

Outlet with a single shut-off valve


3, 4, 6 Washers Should be Used with Plastic - Coated Flanges.

Plastic Ballvalve Plasson 436207 up to 125mm Frialen KH Frialen KHP up to 225mm Cast Iron Gate Valve with PEX/PE (weldable) ends: AVK 36-075-80163 Diameters 75 to 315mm

11-1

PE XG OL

EF Coupler Plasson 490104 Frialen WN Flange Adaptor & Backing Ring Plasson 490207 Plasson 09903

EF Reducing Tee Plasson 491404

11-1

Pexgol Installation Guidelines for Infrastructure pipelines

Shut off valve - Above ground installation


(Up to 160mm) with steel pipes Always use the suitable flange standard!

Steel Pipe

Flange Adaptor & Backing Ring Plasson 490207 Plasson 09903 EF Coupler Plasson 490104 Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Shut off Valve - Above Ground Installation


Air Relief Valve 2

Valve 2

2 Male Transition Coupler Plasson 492104 Frialen MUN

Shut-Off Valve 3/4/6

Flange Adaptor & Backing Ring Plasson 490207 Plasson 09903

Pexgol

EF 90 Elbow PLasson 490504 Frialen - W90

EF Branch Saddle Plasson 495804 outlet 63

Washers Should be Used with Plastic Coated Flanges.


EF 90 Elbow PLasson 490504 Frialen - W90

Pex

go

Pexgol

Pexgol Installation Guidelines for Infrastructure pipelines

Underground Shut - off Valve in a Amnhole


Always use the suitable flange standard!

EF Coupler Plasson 490104 Frialen WN Flange Adaptor & Backing Ring Plasson 490207 Plasson 09903

EF Coupler Plasson 490104 Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Air Relief Valve 3/2

Air Relief Valve 3/2

Angle Seat Valve 3/2

Ball Valve 3/4

Metal Riser 3/2 Transition Fitting Frialen USTM/USTN 63 x 2

EF Coupler Plasson 490104 Frialen WN

EF Branch Saddle 495804 110 /160 x 90/63

Pe

xg

ol

11

0-

16

Pexgol Installation Guidelines for Infrastructure pipelines

Fire Hydrant 3
Fire Hydrant 3

Metal Riser 4x3

No - Flood Safety Device 4x3

Golan GP Hydrant Flange Adaptor

Pex

l go

11

Pexgol 110

Golan Hydrant Pexgol

EF 90 Elbow Plasson 490504 Frialen W90

EF Reducing Tee PLasson 491404 160x110x160 PLasson 490404 110x110x110

Pe

EF Coupler Plasson 490104 Frialen WN


xg ol 11 0-

16

Pexgol Installation Guidelines for Infrastructure pipelines

Fire Hydrant 3
Fire Hydrant 3

PE/Cast Iron - Flange Transition Coupler Plasson 497704 110x4 Metal Riser 4x3

No - Flood Safety Device 4x3

PEXGOL 110

EF 90 Elbow Plasson 490504 Frialen W90

Pe

EF Reducing Tee PLasson 491404 160x110x160 PLasson 490404 110x110x110

xg

ol

11

0-

EF Coupler Plasson 490104 Frialen WN


16 0

Vous aimerez peut-être aussi