Académique Documents
Professionnel Documents
Culture Documents
12V17AH/20HR
Small-Size
Small Size VRLA batteries enjoy excellent discharge performance, and they have low self-discharge and large-current resistance
capacity. Small-size batteries are capable for a wide range of applications. Their designed service life is 3-5 years, and we provide 12-month quality warranty for them. Our batteries can meet Standard Terminal Dimensions with many demanding technical and quality requirements form our customers.
Application
167(6.57)
Emergency lighting Security and burglar alarm systems Electric toys and power tools Telephone and telecommunication equipment Computer UPS Medical equipments and instruments
181(7.13)
77(3.03)
General Features
Sealed and maintenance free operation Not restricted from air transport-complies with IATA/ICAO Special Provision A67. UL-recognized components Safety valve installation for explosion proof Excellent deep discharge recovery performance Low self-discharge ratio Long service life, float or cycle-use applications
Battery Construction
Component Positive plate Lead dioxide Negative plate Lead Container Cover
Terminal
Material
ABS
ABS
Copper
Page 1 of 3
BAT-12V17AH
General Specifications
Battery Model Designed Service Life Capacity (25) Dimension: mm (inch) Approx. Weight Internal Resistance 20HR (0.85A) 17.0AH Length 181 (7.13) 10HR (1.53A) 15.3AH Width 77(3.03)
12V17AH/20HR
BAT-12V17AH(12V17AH/20 HR) 5 years 5HR (2.90A) 14.5AH Height 167(6.57) 1HR (11.1A) 11.1AH Total Height 167(6.57)
5.15Kg (11.36 lbs) Fully charged at 25: 0.03 Ohm 3% of capacity declined per month at 25 40 105% Cycle use 25 100% 0 85% Stand-by use 13.50-13.80V (-20mV/) -15 65%
Self-discharge
Page 2 of 3
120
100
80
20
Number of cycles(Cycles)
BAT-12V17AH
Constant Current Discharge Data
12V17AH/20HR
Constant Current Discharge Data Sheet (Amperes at 25) End Voltage/cell 1.80 1.75 1.70 1.65 1.60 Minute (s) 5 65.9 67.6 69.3 71.1 72.8 10 44.7 46.0 47.2 48.4 49.7 15 34.9 35.8 36.7 37.5 38.4 30 20.4 20.7 21.0 21.4 21.7 1 12.2 12.4 12.6 12.8 13.0 3 4.88 4.96 5.04 5.12 5.20 Hour (s) 5 3.24 3.31 3.37 3.44 3.50 10 1.65 1.69 1.73 1.76 1.79 20 0.84 0.85 0.90 0.91 0.92
End Voltage
Discharge Rate Discharge Current End VoltageV/cell 1.75 1.75 1.75 1.60
20h 10h 3h 1h
Page 3 of 3
Less than 6 months from production or previous top up charge Less than 12 months from production or previous top up charge Less than 6 months from production or previous top up charge Less than 12 months from production or previous top up charge
Page 4 of 3