Vous êtes sur la page 1sur 0

Addendum: 9 pages

DAP-PL-3856.99





CERTIFICATE



TV Rheinland Immissionsschutz
und Energiesysteme GmbH



Manufacturer: Gasmet Technologies Oy, Helsinki, Finnland

Measuring System: GASMET CEMS

Components: CO, NO, NO
2
, N
2
O, SO
2
, HCl, NH
3
, CO
2
and H
2
O

Test Report: 936/ 21200448/A of 2006-07-07




The measurement system fulfils
the requirements of
QAL 1
according to EN 14181 and EN ISO 14956.




Kln, 2006-09-08

Dr. P. Wilbring

Dipl.-Chem. M. Kerpa


www.umwelt-tuv.de / www.eco-tuv.com
tie@umwelt-tuv.de
Tel. +49 - 221 - 806 - 2275
TV Rheinland Immissionsschutz und Energiesysteme GmbH
Am Grauen Stein
51105 Kln

The company is accredited to DIN EN ISO/IEC 17025.
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component N2O 100 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.00 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 300 mg/m Carbon monoxide -1.00 mg/m
to 15 Vol.-% Carbon dioxide 0.00 mg/m
to 50 mg/m Methane 0.00 mg/m
to 300 mg/m Nitrogen monoxide 2.70 mg/m
to 30 mg/m Nitrogen dioxide 0.00 mg/m
to 20 mg/m Ammonia 0.00 mg/m
to 1000 mg/m Sulphur dioxide 0.00 mg/m
to 200 mg/m Hydrogen chloride 0.00 mg/m
Sum of positive cross sensitivities 2.70 mg/m
Sum of negative cross sensitivities -1.00 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L 0.60 mg/m 0.35 mg/m 0.120
Biggest interference (positiv or negativ) u
I 2.70 mg/m 1.56 mg/m 2.430
Span shift in the field test u
d,s 0.70 mg/m 0.40 mg/m 0.163
Zero shift in the field test u
d,z 0.20 mg/m 0.12 mg/m 0.013
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t -0.60 mg/m -0.35 mg/m 0.120
Dependence on supply voltage u
sv -0.60 mg/m -0.35 mg/m 0.120
Repeatability at span u
s 0.10 mg/m 0.06 mg/m 0.003
Field reproducibility u
D 0.98 mg/m 0.57 mg/m 0.321
Uncertainty of the test gas at the reference point u
tg 1.00 mg/m 0.58 mg/m 0.333
Combined standard uncertainty (u
C
) u
c 1.904
Total expanded uncertainty (u
c
* k) 3.731
Relative total expanded uncertainty 3.7
Requirement 20.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 100 mg/m
Uc in % of the limit 100 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component CO 75 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen -0.68 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 15 Vol.-% Carbon dioxide -0.45 mg/m
to 50 mg/m Methane 0.00 mg/m
to 100 mg/m Dinitrogen monoxide 0.68 mg/m
to 300 mg/m Nitrogen monoxide 0.00 mg/m
to 30 mg/m Nitrogen dioxide 0.00 mg/m
to 20 mg/m Ammonia -0.21 mg/m
to 1000 mg/m Sulphur dioxide 0.00 mg/m
to 200 mg/m Hydrogen chloride 0.60 mg/m
Sum of positive cross sensitivities 1.28 mg/m
Sum of negative cross sensitivities -1.34 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -1.43 mg/m -0.82 mg/m 0.677
Biggest interference (positiv or negativ) u
I -1.34 mg/m -0.77 mg/m 0.594
Span shift in the field test u
d,s 0.23 mg/m 0.13 mg/m 0.017
Zero shift in the field test u
d,z 0.23 mg/m 0.13 mg/m 0.017
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t -0.30 mg/m -0.17 mg/m 0.030
Dependence on supply voltage u
sv -0.68 mg/m -0.39 mg/m 0.152
Repeatability at span u
s 0.30 mg/m 0.17 mg/m 0.030
Field reproducibility u
D 1.03 mg/m 0.60 mg/m 0.357
Uncertainty of the test gas at the reference point u
tg 0.75 mg/m 0.43 mg/m 0.188
Combined standard uncertainty (u
C
) u
c 1.435
Total expanded uncertainty (u
c
* k) 2.814
Relative total expanded uncertainty 5.6
Requirement 10.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 50 mg/m
Uc in % of the limit 50 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component NO 200 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.00 mg/m
to 30 Vol.-% Humidity -1.40 mg/m
to 300 mg/m Carbon monoxide 1.20 mg/m
to 15 Vol.-% Carbon dioxide -4.00 mg/m
to 50 mg/m Methane 0.00 mg/m
to 100 mg/m Dinitrogen monoxide 0.00 mg/m
to 30 mg/m Nitrogen dioxide 0.00 mg/m
to 20 mg/m Ammonia 0.96 mg/m
to 1000 mg/m Sulphur dioxide 0.00 mg/m
to 200 mg/m Hydrogen chloride 0.00 mg/m
Sum of positive cross sensitivities 2.16 mg/m
Sum of negative cross sensitivities -5.40 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -2.60 mg/m -1.50 mg/m 2.253
Biggest interference (positiv or negativ) u
I -5.40 mg/m -3.12 mg/m 9.720
Span shift in the field test u
d,s 0.00 mg/m 0.00 mg/m 0.000
Zero shift in the field test u
d,z 0.20 mg/m 0.12 mg/m 0.013
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t 3.60 mg/m 2.08 mg/m 4.320
Dependence on supply voltage u
sv -4.20 mg/m -2.42 mg/m 5.880
Repeatability at span u
s 2.00 mg/m 1.15 mg/m 1.333
Field reproducibility u
D 0.85 mg/m 0.49 mg/m 0.241
Uncertainty of the test gas at the reference point u
tg 2.00 mg/m 1.15 mg/m 1.333
Combined standard uncertainty (u
C
) u
c 5.009
Total expanded uncertainty (u
c
* k) 9.818
Relative total expanded uncertainty 7.5
Requirement 20.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 130 mg/m
Uc in % of the limit 130 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component NO2 200 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 1.40 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 300 mg/m Carbon monoxide 0.00 mg/m
to 15 Vol.-% Carbon dioxide -1.60 mg/m
to 50 mg/m Methane 0.00 mg/m
to 100 mg/m Dinitrogen monoxide 0.00 mg/m
to 300 mg/m Nitrogen monoxide 1.80 mg/m
to 20 mg/m Ammonia -0.48 mg/m
to 1000 mg/m Sulphur dioxide 3.00 mg/m
to 200 mg/m Hydrogen chloride -1.80 mg/m
Sum of positive cross sensitivities 6.20 mg/m
Sum of negative cross sensitivities -3.88 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -1.20 mg/m -0.69 mg/m 0.480
Biggest interference (positiv or negativ) u
I 6.20 mg/m 3.58 mg/m 12.813
Span shift in the field test u
d,s 5.00 mg/m 2.89 mg/m 8.333
Zero shift in the field test u
d,z 0.40 mg/m 0.23 mg/m 0.053
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t 1.20 mg/m 0.69 mg/m 0.480
Dependence on supply voltage u
sv -1.60 mg/m -0.92 mg/m 0.853
Repeatability at span u
s 2.00 mg/m 1.15 mg/m 1.333
Field reproducibility u
D 2.69 mg/m 1.55 mg/m 2.404
Uncertainty of the test gas at the reference point u
tg 2.00 mg/m 1.15 mg/m 1.333
Combined standard uncertainty (u
C
) u
c 5.299
Total expanded uncertainty (u
c
* k) 10.387
Relative total expanded uncertainty 5.1
Requirement 20.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 200 mg/m
Uc in % of the limit 200 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component SO2 75 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen -0.53 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 300 mg/m Carbon monoxide -0.60 mg/m
to 15 Vol.-% Carbon dioxide 0.00 mg/m
to 50 mg/m Methane 1.13 mg/m
to 100 mg/m Dinitrogen monoxide 0.53 mg/m
to 300 mg/m Nitrogen monoxide -0.53 mg/m
to 30 mg/m Nitrogen dioxide -0.53 mg/m
to 20 mg/m Ammonia 0.48 mg/m
to 200 mg/m Hydrogen chloride 0.00 mg/m
Sum of positive cross sensitivities 2.13 mg/m
Sum of negative cross sensitivities -2.18 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -0.98 mg/m -0.56 mg/m 0.317
Biggest interference (positiv or negativ) u
I -2.18 mg/m -1.26 mg/m 1.577
Span shift in the field test u
d,s 1.80 mg/m 1.04 mg/m 1.080
Zero shift in the field test u
d,z 0.53 mg/m 0.30 mg/m 0.092
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t -1.43 mg/m -0.82 mg/m 0.677
Dependence on supply voltage u
sv -1.35 mg/m -0.78 mg/m 0.608
Repeatability at span u
s 0.68 mg/m 0.39 mg/m 0.152
Field reproducibility u
D 1.06 mg/m 0.61 mg/m 0.377
Uncertainty of the test gas at the reference point u
tg 0.75 mg/m 0.43 mg/m 0.188
Combined standard uncertainty (u
C
) u
c 2.251
Total expanded uncertainty (u
c
* k) 4.412
Relative total expanded uncertainty 8.8
Requirement 20.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 50 mg/m
Uc in % of the limit 50 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component HCl 15 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.14 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 300 mg/m Carbon monoxide 0.23 mg/m
to 15 Vol.-% Carbon dioxide 0.29 mg/m
to 50 mg/m Methane 0.00 mg/m
to 100 mg/m Dinitrogen monoxide -0.12 mg/m
to 300 mg/m Nitrogen monoxide 0.11 mg/m
to 30 mg/m Nitrogen dioxide 0.11 mg/m
to 20 mg/m Ammonia 0.00 mg/m
to 1000 mg/m Sulphur dioxide 0.00 mg/m
Sum of positive cross sensitivities 0.86 mg/m
Sum of negative cross sensitivities -0.12 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -0.24 mg/m -0.14 mg/m 0.019
Biggest interference (positiv or negativ) u
I 0.86 mg/m 0.49 mg/m 0.244
Span shift in the field test u
d,s 0.41 mg/m 0.23 mg/m 0.055
Zero shift in the field test u
d,z 0.06 mg/m 0.03 mg/m 0.001
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t 0.48 mg/m 0.28 mg/m 0.077
Dependence on supply voltage u
sv -0.17 mg/m -0.10 mg/m 0.009
Repeatability at span u
s 0.14 mg/m 0.08 mg/m 0.006
Field reproducibility u
D 0.21 mg/m 0.12 mg/m 0.015
Uncertainty of the test gas at the reference point u
tg 0.30 mg/m 0.17 mg/m 0.030
Combined standard uncertainty (u
C
) u
c 0.675
Total expanded uncertainty (u
c
* k) 1.323
Relative total expanded uncertainty 13.2
Requirement 40.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 10 mg/m
Uc in % of the limit 10 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Emission Measurement
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
TV Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component NH3 15 mg/m
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.00 mg/m
to 30 Vol.-% Humidity 0.00 mg/m
to 300 mg/m Carbon monoxide 0.12 mg/m
to 15 Vol.-% Carbon dioxide 0.17 mg/m
to 50 mg/m Methane 0.00 mg/m
to 100 mg/m Dinitrogen monoxide 0.15 mg/m
to 300 mg/m Nitrogen monoxide 0.15 mg/m
to 30 mg/m Nitrogen dioxide 0.00 mg/m
to 1000 mg/m Sulphur dioxide -0.20 mg/m
to 200 mg/m Hydrogen chloride 0.00 mg/m
Sum of positive cross sensitivities 0.59 mg/m
Sum of negative cross sensitivities -0.20 mg/m
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L -0.26 mg/m -0.15 mg/m 0.022
Biggest interference (positiv or negativ) u
I 0.59 mg/m 0.34 mg/m 0.114
Span shift in the field test u
d,s 0.32 mg/m 0.18 mg/m 0.033
Zero shift in the field test u
d,z 0.05 mg/m 0.03 mg/m 0.001
Sensitivity to sample volume flow u
v 0.00 mg/m 0.00 mg/m 0.000
Sensitivity to ambient temperature u
t -0.29 mg/m -0.16 mg/m 0.027
Dependence on supply voltage u
sv -0.26 mg/m -0.15 mg/m 0.022
Repeatability at span u
s 0.09 mg/m 0.05 mg/m 0.003
Field reproducibility u
D 0.14 mg/m 0.08 mg/m 0.006
Uncertainty of the test gas at the reference point u
tg 0.30 mg/m 0.17 mg/m 0.030
Combined standard uncertainty (u
C
) u
c 0.507
Total expanded uncertainty (u
c
* k) 0.994
Relative total expanded uncertainty 6.6
Requirement 40.0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
Result: Requirements keep to QAL 1 of EN 14181
U
c
=u
c
* 1,96
Uc in % of the limit 15 mg/m
Uc in % of the limit 15 mg/m
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Gasmessgert
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
Approval Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component CO2 25 Vol.-%
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.00 Vol.-%
to 30 Vol.-% Humidity -0.20 Vol.-%
to 300 mg/m Carbon monoxide 0.00 Vol.-%
to 50 mg/m Methane 0.00 Vol.-%
to 100 mg/m Dinitrogen monoxide 0.00 Vol.-%
to 300 mg/m Nitrogen monoxide 0.00 Vol.-%
to 30 mg/m Nitrogen dioxide 0.00 Vol.-%
to 20 mg/m Ammonia 0.00 Vol.-%
to 1000 mg/m Sulphur dioxide 0.00 Vol.-%
to 200 mg/m Hydrogen chloride -0.30 Vol.-%
Sum of positive cross sensitivities 0.00 Vol.-%
Sum of negative cross sensitivities -0.50 Vol.-%
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L
0.33 Vol.-% 0.19 Vol.-% 0.035
Biggest interference (positiv or negativ) u
I
-0.50 Vol.-% -0.29 Vol.-% 0.083
Span shift in the field test u
d,s
0.10 Vol.-% 0.06 Vol.-% 0.003
Zero shift in the field test u
d,z
0.05 Vol.-% 0.03 Vol.-% 0.001
Sensitivity to sample volume flow u
v
0.00 Vol.-% 0.00 Vol.-% 0.000
Sensitivity to ambient temperature u
t
-0.33 Vol.-% -0.19 Vol.-% 0.035
Dependence on supply voltage u
sv
0.40 Vol.-% 0.23 Vol.-% 0.053
Repeatability at span u
s
0.03 Vol.-% 0.01 Vol.-% 0.000
Field reproducibility u
D
0.10 Vol.-% 0.06 Vol.-% 0.003
Uncertainty of the test gas at the reference point u
tg
0.50 Vol.-% 0.29 Vol.-% 0.083
Combined standard uncertainty (u
C
) u
c 0.546
Total expanded uncertainty (u
c
* k) 1.070
Relative total expanded uncertainty 4.3
Requirement 10,0
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
CS
U
c
=u
c
* 1,96
Uc in % of the range 25 Vol.-%
Uc in % of the range 25 Vol.-%
Result: Requirements keep to QAL 1 of EN 14181
Attention: For this component no requirements in the EC-directives 2001/80/EG und 2000/76/EG are given.
j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =
Manufacturer data
Manufacturer Gasmet Technologies Oy
Measurement System Gasmessgert
Name Gasmet CEMS
Serial Number 033305 und 03306
Measuring Principle FTIR
TV Data
Approval Report 936/21200448/A
Date 06.07.2006
Editor Dipl.-Chem. M. Kerpa
Measurement Component H2O 30 Vol.-%
Evaluation of the cross sensitivity (CS)
to 21 Vol.-% Oxygen 0.00 Vol.-%
to 300 mg/m Carbon monoxide 0.00 Vol.-%
to 15 Vol.-% Carbon dioxide 0.45 Vol.-%
to 50 mg/m Methane 0.00 Vol.-%
to 100 mg/m Dinitrogen monoxide 0.00 Vol.-%
to 300 mg/m Nitrogen monoxide 0.00 Vol.-%
to 30 mg/m Nitrogen dioxide 0.00 Vol.-%
to 20 mg/m Ammonia 0.00 Vol.-%
to 1000 mg/m Sulphur dioxide 0.00 Vol.-%
to 200 mg/m Hydrogen chloride 0.78 Vol.-%
Sum of positive cross sensitivities 1.23 Vol.-%
Sum of negative cross sensitivities -0.24 Vol.-%
Calculation of the combined standard uncertainty
Test Value
Lack of fit u
L
-0.57 Vol.-% -0.33 Vol.-% 0.108
Biggest interference (positiv or negativ) u
I
1.23 Vol.-% 0.71 Vol.-% 0.504
Span shift in the field test u
d,s
-0.27 Vol.-% -0.16 Vol.-% 0.024
Zero shift in the field test u
d,z
0.09 Vol.-% 0.05 Vol.-% 0.003
Sensitivity to sample volume flow u
v
0.00 Vol.-% 0.00 Vol.-% 0.000
Sensitivity to ambient temperature u
t
-0.42 Vol.-% -0.24 Vol.-% 0.059
Dependence on supply voltage u
sv
-0.51 Vol.-% -0.29 Vol.-% 0.087
Repeatability at span u
s
0.06 Vol.-% 0.03 Vol.-% 0.001
Field reproducibility u
D
0.29 Vol.-% 0.17 Vol.-% 0.029
Uncertainty of the test gas at the reference point u
tg
0.60 Vol.-% 0.35 Vol.-% 0.120
Combined standard uncertainty (u
C
) u
c 0.967
Total expanded uncertainty (u
c
* k) 1.895
Relative total expanded uncertainty 6.3
Requirement 10,0 Uc in % of the range 30 Vol.-%
Result: Requirements keep to QAL 1 of EN 14181
Attention: For this component no requirements in the EC-directives 2001/80/EG und 2000/76/EG are given.
U
c
=u
c
* 1,96
Uc in % of the range 30 Vol.-%
DIN EN ISO 14956 and prEN 15267-3 calculation for QAL 1 in DIN EN 14181
CS j X max,
j X max,

3
) (
max,
X
X u
j

= 2
max,
) (
j
X u

2
max,
) (
j c
u u =

Vous aimerez peut-être aussi