Académique Documents
Professionnel Documents
Culture Documents
en.nanhua.com
Company Profile
Shanghai Nanhua was established in 1990 with registration capital of RMB 5,000,000. Till July, 2012,we have 229 staff in total, including 38 R & D engineers and 5000 workshop. We got ISO 9001 and CSQA quality certificate. Since 2006, we have been concentrating on the designing, manufacturing and trading of anemometer. The design is strictly complying with National Meteorology Industry Standard QX/T 23 and National Bureau of standards and Metrology verification regulation of wind speed and vane sensor. We own completed production lines and strict quality control system. What we insist on is continuously improving the products on the stability and details of the quality. Our anemometers are widely applicable to wind power, wind farm monitoring, small meteorology station, port/ engineering machinery and photovoltaic project, etc. Most of all, we gradually constitute a professional products system including wind speed/direction sensor, data loggers, data storage / analysis/system integration, wireless data transmission and network, etc.
01/02
FA10 Series
FA13 Series FA21 series Wireless anemometer application
IP65
Application
Special design for plant, electric power, harbor, factories and mines, wind generator etc large mechanical equipments.
175
3-M6
12
Aviation plug
Description
Operating voltage Measuring range Accuracy Start speed Anti-wind strength Signal output Communication port Multi-channels alarm output Digital display
Parameter
AC85V~AC265V (FA101C) 0~60 (m/s) i.e.0-17 wind scales (0.4+0.05x actual wind speed) m/s <0.5m/s > 60 m/s Current loop 4~20mA output ; RL<500 RS485 2 channel relay control output (2NO/2NC), Internal alarm, sound output and digital communication output Display : four digits Display content : wind speed and wind scale (switchable) Refreshing frequency : 1s/time
FA101C Displayer
-30C ~ +70C 0% ~ 95% (no coagulation) IP65 (FA101A) Sensor : PC+ABS Displayer : ABS FA101A : 0.3Kg
45 216 57 174
FA101C : 0.5Kg
195
Shielded cable
100 4-5.5
Red
L N G Power input
NO NC Pre-alarm
NO NC (Alarm)
I+ I4-20mA (Output)
3-M20x1.5
135
03/04
FA10 Series FA13 Series FA21 series Wireless anemometer application
IP65
Application
Special design for large equipments of factory, wind industry, engineering machinery, port machinery, mining area,etc.
70
Description
Operating voltage Operating current Start speed Anti-wind strength Measuring range Resolution Accuracy Heating type Heating voltage Heating power Surge protection ESD protection Operation temperature Humidity Body material IP grade Wind cup material Weight
Parameter
VCC=DC12V-DC30V <50mA 0.5m/s > 70 m/s 0.5-50m/s 0.01m/s 0.5 m/s (<5m/s) Measured value 3% (5 m/s) PTC Auto-heating 50W 4KV/2KA 15KV -40C ~ +70C 0%~95% (no coagulation) Aluminum alloy / Polyester coating IP65 SS304 FA13xA/FA13xD=0.6KG, FA13xB=2.5KG
G3/4" Length of threaded Aviation plug Default Cable length 3M Thickness of cleat 160.5 section Aviation plug Default Cable length 3M
DC24V6V
44
165.5
Model
FA133A FA133D FA135A FA135D
Mounting type
42~54 pipe G3/4whorl 42~54 pipe G3/4whorl
wiring
Aviation plug Aviation plug Aviation plug Aviation plug
Signal output
420mA signal output (liner wind speed 0~50m/s) Load resistance500 NPN pulse signal output; open-collector output; 0.5m/s=2Hz50m/s=573Hz V[m/s]=0.08669f[Hz]+0.32 Yellow White
4-20mA PLC
I+ I out+
3 7
GND
2
NPN PLC
+ pulse
3 7
GND
2
Water-proof test
05/06
FA10 Series FA13 Series FA21 series Wireless anemometer application
IP65
Application
Special design for Crawler crane, Truck crane, Bridge inspection vehicle etc. large lift, cantilever machinery.
Anemometer sensor uses magnetic sensor measuring principle. Sensor data collected with high precision and reliability. Special design for heavy equipment, modern design, self-adjusting vertical angle. Wind speed sensor uses metal enclosure, corrosion resistant. Wind cup stainless steel with strong anti-wind capability. Compact sensor design, set wind speed measurement, heating device in one, easy installation and maintenance. Sensor fault-tolerant design, sensor will not be damaged even wrong wiring. Multi-level surge protection design.
289
4-7
154
>1
>1 40
Description
Operating voltage Operating current Measuring range Start speed Anti-wind strength Accuracy Heating type Heating voltage Heating power Surge protection ESD protection Operation temperature Humidity Body material IP grade Wind cup material Weight
Parameter
VCC=DC12V-DC30V <50mA 0.5-50m/s 0.5m/s >70 m/s 0.5 m/s (<5m/s) Measured value 3% (5 m/s) PTC Automatic DC24V6V 50W 4KV/2KA 15KV -40C ~ +70C 0%~95% (non-condensing) Aluminum alloy / Polyester coating IP65 SS304 2.5KG Heat24V+ Heat24V- VCC
6 5 1
4-20mA PLC
I+ I out+
3 7
GND
2
NPN PLC
+ pulse
3 7
Model
FA133B FA135B
Mounting type
Self-balance Self-balance
wiring
Direct wiring Direct wiring
Signal output
420mA signal output (liner wind speed 0~50m/s) Load resistance500 NPN pulse signal output; open-collector output; 0.5m/s=2Hz50m/s=573Hz V[m/s]=0.08669f[Hz]+0.32
GND
2
IP65
Application
Special designed for wind turbine, engineering machinery, port machinery, bridge machinery etc large equipments.
Anemometer sensor uses magnetic sensor measuring principle. Sensor data collected with high precision and reliability. Wind vane uses metal enclosure, corrosion resistant and strong anti-wind capability. Compact sensor design, set wind speed measurement, heating device in one, easy installation and maintenance. Sensor fault-tolerant design, sensor will not be damaged even wrong wiring. Multi-level surge protection design.
Description
Operating voltage Operating current Start speed Anti-wind strength Measuring range Resolution Accuracy Heating type Heating voltage Heating power Surge protection ESD protection Operation temperature Humidity Body material IP grade material Weight
Parameter
VCC=DC12V-DC30V <50mA 0.5m/s >70 m/s 0~360 0.35 PTC Auto-heating DC24V6V 50W 4KV/2KA 15KV -40C ~ +70C 0%~95% (no coagulation) Aluminum alloy/ Polyester coating IP65 Carbon fiber+SS304 0.6KG Yellow
G3/4" Aviation plug Default Cable length 3M 44
12
70
I-
214
220
4-20mA PLC
I+ I out+
3 7
Model
FA132A FA132D
Mounting type
42~52 pipe G3/4whorl
wiring
Aviation plug Aviation plug
Signal output
4~20mA signal output (liner wind direction 0~360); Load resistance500 Heat24V+ Heat24V- VCC
6 5 1
GND
2
07/08
FA10 Series
FA13 Series FA21 series Wireless anemometer application
FA133A
FA132A
FA130C
IP65
Application
Special design for plant, electric power, harbor, factories and mines, wind generator etc large mechanical equipments.
162
70
165.5
70
FA133A
FA132A
220
FA133A/FA132A
Description
Operating voltage Operating current Start speed Anti-wind strength Heating type Heating voltage Heating power Surge protection ESD protection Operation temperature Humidity Body material IP grade Wind cup material Wind vane material Wind speed signal output Wind direction signal output
Parameter
VCC=DC12V-DC30V <50mA 0.5m/s >70m/s PTC Auto-heating DC24V 6V 50W 4KV/2KA 15KV -40C ~ +70C 0%~95% (no coagulation) Aluminum alloy / Polyester coating IP65 SS304 Carbon fiber + SS304 4~20mA signal output (liner wind speed 0~50m/s) ; Load resistance 500 4~20mA signal output (liner wind direction 0~360); Load resistance 500
Model
Measuring range Resolution Accuracy Weight
FA133A
0.5-50m/s 0.01m/s 0.5m/s (<5m/s); Measured value 3% (5 m/s) 0.6KG
FA132A
0~360 0.35
270 330 550 Aviation plug Default cable length 3M Installation of outer diameter < 54 Installation of inner diameter > 42 30
2 0.6KG
FA130C
Description
Operating voltage Communication Wind speed range Wind direction range Wind speed display resolution Wind direction display resolution Wind speed display accuracy Wind direction display accuracy Multi-channels alarm output
Parameter
AC85V~AC265V RS485 0~99.9 (m/s) 0~359 0.1m/s 1 0.5 m/s (<5m/s); Measured value 3% (5 m/s) 5 Two way relay control output (Pre alarm NO/ Alarm NC) Internal alarm output, RS485 digital communication output 4 ~ 20mA current output (linear correspond 0 ~ 359), load resistance 500
Digital display
Display: three digits wind speed or three digits angle, 16 wind direction Display content: wind speed or 0~359 angle wind direction (i.e. east, west, south, north etc. 16 direction ) Refreshing frequency: 1 second
5 White
Yellow
NO Pre-alarm
NO Alarm
I+
I-
Iout
Power input
4-20mA Output
09/10
FA10 Series
FA13 Series FA21 series Wireless anemometer application
IP65
Application
Special design for plant, electric power, harbor, factories and mines, wind generator etc large mechanical equipments.
68 332
84
330 162
402 664
33
62
1 FA213A+PJ3001 2 FA213A+PJ3002
Description
Operating voltage Operating current Start speed Anti-wind strength Heating voltage Heating power Heating type Surge protection ESD protection Operation temperature Humidity Installation wiring Body material IP grade Wind cup material Wind Vane material Weight
Parameter
VCC=DC12V-DC30V <100mA 0.5m/s >70m/s DC24V6V PTC Auto-heating 4KV/2KA 15KV -40~+70 0%~95% (no coagulation) PJ3001 or PJ3002 bracket for option Aviation plug Aluminum alloy / Polyester coating IP65 SS304 Carbon fiber+SS 304 2.8KG
40 90 A-A:PJ3002 Flange base drawing 162 6-8 (36) 8 120 86 (120) B-B: Hole drawing 673 155 332 500 A B A B Flange Customer-supplied
100W
83
Model
Resolution Measuring range Accuracy Signal output
74
11/12
FA10 Series FA13 Series FA21 series Wireless anemometer application
IP65
Application
Special design for power plant, electric power, harbor, factories and mines, wind generator etc large mechanical equipments.
Mounting dimension
Insert SD card
40
40
40
Operating voltage Communication Wind speed range Wind direction measuring range Wind speed display resolution Wind direction display resolution Wind speed accuracy Wind speed alarm output
AC85VAC265V RS485 099.9m/s 0359 0.1m/s 1 0.5 m/s(<5m/s);Measured value 3% (5 m/s) Wind direction accuracy 5 Two way relay control output (Pre alarm NO/ Alarm NC) Internal alarm, sound output and digital communication output 4~20mA signal output (linear correspond 0~360), load resistance 500.
6 Heat 24V+ Heat 24VYellow Power DC24V
Digital display
Display: four digits wind speed or three digits angle, 16 direction Display content: wind speed or 0~359 and direction (East, South, West, North etc 16 direction) Refreshing frequency1 second/time
White
7 Shielded cable
4 Iout Blue
3 Iout
16
2 GND
100
Description
Parameter
142
1 VCC
Data Logger
Built-in timing system for seeing and setting. Normal temperature 25C; yearly time tolerance2.5 min Time system powered by built-in battery; no need to set time even power interrupts within 6 months Data was stored by standard SD card in TXT format.
L N G NO NO Power input Pre-alarm Alarm I+ I- Iout 24V- 24V+ Iout 24V- 24V+ 4-20mA Vane Anemometer Output
55
13/14
FA10 Series
FA13 Series FA21 series Wireless anemometer application
Application
This whole device has been installed on the Shanghai Center for testing wind speed, wireless date transmission and monitoring.
ZigBee Wireless sender and receiver FA231W) FA221C Data logger & displayer Wireless relay (Optional)
Control room