PH1 Range - PULL HANDLE CALL POINT

Exd, Weatherproof Features


Zone 1 and Zone 2 use. Ex d IIC T6 Gb Ex tb IIIC T85C Db IECEx certified Gb, Db ATEX certified Ex II 2 GD IP66 & 67 Certified temperature: -55C to +70C Corrosion free GRP construction Optional in line, end of line resistors and diodes Retained stainless steel cover screws

Introduction
The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS130/A

Specification
Certification: Certified to IEC60079-0, IEC60079-1 and IEC60079-31 Certified to EN60079-0, EN60079-1 and EN60079-31 IECEx Cert. No. IECEx ITS 11.0021X Atex Cert. No. ITS11ATEX17308X Ex II 2 GD Ex d IIC T6 Gb, Ex tb IIIC T85C Db Body/covers/handles:- GRP (glass reinforced polyester) Fixings:- Stainless steel grade 316 Cover:- natural red, Body:- natural black. Handles:- natural white. Cover may be painted to customer's requirements. 0-50Vdc, 0-254Vac. 1 or 2 c/o switches, 254V, 3A max. Gross weight 3.2Kg. Net weight 2.6Kg -55C to +70C. IP66 & 67. Up to 2 x M20 or M25, up to 2 x 1/2 or 3/4 NPT. 6 x 2.5mm2 as standard. Contact Cooper MEDC for options. Earth continuity is provided by internal plate. 'Burning house' label fitted as standard on red units. Blank label fitted as standard on all other colour units. Tag & Duty label options, worded to customers requirements. Consult Cooper MEDC for options. Various configurations available, 470 Ohms minimum. Various configurations available.

Material: Finish:

Voltage: Switch Rating: Weight: Certified Temp: Ingress Protection: Entries: Terminals: Earth Continuity: Labels:

Addr. module: Resistors: Diodes:

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring switch only

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring c/w EOL resistor


R1 - EOL Resitor

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring c/w series resistor or series & EOL resistor


R1 - Series Resitor R2 - EOL Resitor (if fitted)
ALL DIMENSIONS IN MILLIMETRES

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box.
Model PH1 Certification ATEX IECEx Code B J Entries M20 M25 1/2" NPT 3/4" NPT Code *B *C *M *N Switches Single changeover Double changeover Code S D Features None Series resistor EOL resistor Diode Tag label Duty label
* Please specify

Certification

Entries

Switches

Features

Finish

* Prefix entry size with entry position (see diagram above). E.g. 4B6B. Maximum 2 Entries

Code N G* H* E* T* D*

Finish Natural Red Special


* Please specify

Code R S*

NOTE: the units can be internally wired to suit customers specifications. Please discuss your requirements with us.
All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12