Vous êtes sur la page 1sur 85

320 3 MS.

ANNY CHAN

MS. ANNY CHAN DELTA ELECTRONICS INC 3 TUNGYUAN RD CHUNGLI INDUSTRIAL ZONE TAOYUAN COUNTY 32063 TAIWAN

Date: Subscriber: PartySite: File No: Project No: PD No: Type: PO Number:

2012/07/05 673621002 150609 E131881 12CA33784 12O26016 R DCBU-CN-20120500

Subject: Procedure And/Or Report Material The following material resulting from the investigation under the above numbers is enclosed. Issue Date Vol Sec Pages Revised Date
2012/05/18 X7 X7 A1485 Index Page(s) Revised Proc/Rpt Section

"If there are illegible images in this package, legible images may be found online via MyHome@UL under My UL Reports/CDA." Please file revised pages and illustrations in place of material of like identity. New material should be filed in its proper numerical order. NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and Appendixes. Please review this material and report any inaccuracies to UL's Customer Service Professionals. Contact information for all of UL's global offices can be found at http://www.ul.com/global/eng/pages/corporate/contactus. If youd like to receive updated materials FASTER, UL offers electronic access and/or delivery of this material. For more details, contact UL's Customer Service Professionals as shown above. This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL. TPI File

File E131881 Index

Volume X7

Page 1

Date: 2012-07-03

Index
Product Type Model/Type Reference Switching Power supply (built-in) Power Supply, BuiltIn AC/DC Power Supply, BuiltIn AC/DC Power Supply, BuiltIn AC/DC Power Supply, BuiltIn AC/DC Power Supply, BuiltIn AC/DC Power Supply, BuiltIn DC/DC DPS-340BB XX and DPS-350TB XX, where X might be any alphanumeric character or blank Report Status Reference # E131881A9-UL

DPS-150LP XX and DPSN-150HP XX (where "X" is any E131881alphanumeric character or blank for marketing purpose and no A10-UL impact safety related critical components and constructions.) DPS-400GB-1 XX (X = 0-9, A-Z or blank) E131881A13-UL DPS-1600BB XX, DPS-2000BB XX (where "X" is any alphanumeric character or blank) ADP-60AF and ADP-58AF ADP-36AF E131881A14-UL E131881A16-UL E131881A17-UL E131881A20-UL

Q48SBX1X2XXXX (X1=120; X2=20 or 25; X1=108, X2=28; X= alphanumeric character, +, *, #, _, hyphen or blank), excluding Model Q48SB12020NVFA which had been certified under E131881-A730. Power DPS-185GB XX, DPS-185JB XX, DPS-185JB-1 XX, DPSSupply, Built- 220BB XX (X=0-9, A-Z, or blank) In AC/DC (PS3) Power 1. RPS-600-4 XX (Cage, where X can be 0-9, A-Z or blank) Supply, Built- 2. RPS-300 XX (Cage, where X can be 0-9, A-Z or blank) In AC/DC 3. DPS-300NB XX (Module, where X can be 0-9, A-Z or blank

E131881A31-UL

E131881A35-UL

Switching DPS-160HB-1 XX (where XX is any alphanumeric character or E131881Power Supply blank.) A36-UL Power DPSN-125BB XX (where "X" is any alphanumeric character or E131881Supply, Built- blank) A87-UL In AC/DC (PS3) Power D48S2R545 X (where "X" is any alphanumeric character or E131881Supply, Built- blank) A93-UL In DC/DC Open frame ADP-23AF A E131881power supply A94-UL Power DPS-162AB XX, (X= 0-9, A-Z or blank) E131881Supply, BuiltA95-UL In AC/DC Power D48SX1X2XXXX (where X1 can be 05, 3R3 and 12 which E131881Supply, Built- represent the output voltage; X2 can be 01 to 30 which A100-UL In DC/DC represent the output current, X can be any alphanumeric, blank (PS4) or dash) Power DPSN-150GB XX (where X = 0 - 9, A - Z or blank) E131881Supply, BuiltA101-UL In AC/DC

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 2

Date: 2012-07-03 Withdrawn

Power DPSN-540BB XX (where X = 0 - 9, A - Z or blank) E131881Supply, BuiltA102-UL In AC/DC Switching AC-025 XX, AC-038 XX, DPS-700EB XX, DPS-750EB XX, AC- E131881Power Supply 050 XX, where X = 0-9, A-Z or blank. A104-UL Power E48SRX1X2XXXXX(X1= 1R2, 1R5, 1R8 and X2=25) E131881Supply, Built- E48SRX1X2XXXXX(X1=2R5 and X2=20) A109-UL In DC/DC E48SRX1X2XXXXX(X1=3R3 and X2=20 or 25) E48SRX1X2XXXXX(X1=050 and X2=12) E48SRX1X2XXXXX(X1=120 and X2=05, 06 or 07) E48SRX1X2XXXXX(X1=150 and X2=04 ) E48SRX1X2XXXXX(X1=120 and X2=04) (X can be any alphanumeric, +, *, #, _, hyphen or blank) Power S48SAX1X2XXXX (X1=050, X2=06; X1=120, X2=03; X1=1R2, E131881Supply, Built- 1R5, 1R8, X2=12; X1=2R5, X2=10; X1=3R3, X2=05 or 10; X= A114-UL In DC/DC alphanumeric character, +, *, #, _, hyphen or blank) Power DPSN-75AP XX (where "X" is any alphanumeric character or E131881supply, Built- blank) A118-UL in AC/DC Power NPAX1X2X3X4X5 and NXAX1X2X3X4X5 (where X1 can be E131881supply, Built- two digits which specifies the input voltage, X2 can be M or P A119-UL in DC/DC which specifies the package type, X3 can be 3 digits or two digits with one letter which specifies the output voltage, X4 can be two digits which specifies the output current, X5 can be 0-5 letters, digits, dash or blank) DC to DC 12S2520XXXX, 12S2515XXXX where X can be any E131881Converter alphanumeric, dash or blank. A121-UL DC to DC 12S2506XXXX (X= alphanumeric character, +, *, #, _, hyphen E131881Converter or blank) A124-UL NC12SX1X206XXXX (X1=1R2, 1R5, 1R8, 2R5, 3R3, 050 or 0A0; X2=H or V; X= alphanumeric character, +, *, #, _, hyphen or blank) Power DPSN-210AB XX (where X can be 0 to 9, A to Z or blank) E131881Supply, BuiltA130-UL In AC/DC Switching DPS-215AB XX, where X may be any alphanumeric character E131881Power Supply or blank. A132-UL Power DPSN-225CP XX E131881Supply, Built- (1st X=0-9, A-Z or blank, except G; 2nd X=0-9, A-Z or blank) A135-UL In AC/DC DPSN-225CP GX (X=0-9, A-Z or blank) Switching DPS-400GB XX, DPS-460BB XX, DPS-400GB-2 XX, DPSE131881Power Supply 500JB XX, DPS-525EB XX, AC-029 XX, where X = 0-9, A-Z or A142-UL blank. Switching 1.) DPS-730AB XX for power supply unit and AC-026 XX for E131881Power Supply back-plane unit. A144-UL 2.) DPS-830AB XX for power supply unit and AC-051 XX for back-plane unit. (where X = 0-9, A-Z or blank.) Power DPS-1300AB XX and DPS-1300AB BX; where XX can be 0-9, E131881Supply, Built- A-Z or blank. A145-UL In AC/DC

Withdrawn

Withdrawn

File E131881 (PS3) Power Supply, BuiltIn AC/DC (PS3) Index

Volume X7

Page 3

Date: 2012-07-03

GPS-350CX-1XX X, GPS-350CC-1XX X, GPS-350CD-1XX X E131881GPS-300CX-1XX X, GPS-350CX-2XX X, GPS-300CC-1XX X, A149-UL GPS-350CC-2XX X, GPS-300CD-1XX X, GPS-350CD-2XX X, GPS-250CX-1XX X, GPS-300CX-2XX X, GPS-250CC-1XX X, GPS-300CC-2XX X, GPS-250CD-1XX X, GPS-300CD-2XX X, GPS-200CC-1XX X, GPS-300CC-3XX X, GPS-200CD-1XX X, GPS-300CD-3XX X (The first X in the type designation(not all models) can be A, B or N designation use of PFC choke. A: Active PFC Choke, B: Passive PFC Choke, N: No PFC Choke. The last three symbols "X" in type designation may be any alphanumeric character or blank and denotes minor differences not affecting safety) DC-DC Q48SRX1X2XXXX, where X1=1R2, X2=40; X1=1R8, X2=25 or E131881Converter 40 or 60; X1=3R3, X2=25 or 35, 50; X=alphanumeric A150-UL character, +, *, #, _, hyphen or blank. Switching DPSN-9BP XX, where X may be any alphanumeric character E131881Power Supply or blank. A154-UL Switching DPSN-100HP XXX, DPSN-100BP XXX (First X=0-9, A-Z, E131881Power Supply except C, G, M or blank; others X= 0-9, A-Z or Blank) A155-UL DPSN-100BP CXX, DPSN-100BP GXX, DPSN-100BP MXX (Where X= 0-9, A-Z or Blank) D550P-00

Withdrawn

Switching E131881Power Supply A156-UL DC-DC DCT48125X, where X can be any alphanumeric or blank E131881Converter A160-UL Switching DPS-200PB-154 XX, DPS-200PB-161 XX and DPS-200PBE131881Power Supply 163 XX, where X may be any alphanumeric character or blank. A161-UL Power DPS-300QB XX, DPS-300QB-1 XX (X can be any E131881Supply, Built- alphanumeric or blank) A162-UL In AC/DC (PS3) Power D24B4301 X where X can be any alphanumeric or blank E131881supply, BuiltA164-UL in DC/DC Power DPS-250AB-2 XX, the first X can be any alphanumeric or blank E131881Supply, Built- except A; A165-UL In AC/DC DPS-250AB-2 AX where X can be any alphanumeric or blank. DC to DC DPS-540AB XX, where X may be any alphanumeric character E131881converter or blank. A170-UL Switching DPS-600PB XX, DPS-600PB-1 XX(HP RMN: CSPRA-PS01), E131881Power Supply AC-034 XX, where X can be any alphanumeric character or A171-UL blank. Switching DPS-500HB XX used with back accessory AC-027XX; E131881Power Supply A172-UL DPS-550EB XX used with back accessary AC-037 XX. DPS-500LB XX used without back accessary. Where X canbe any alphanumeric or blank. Switching GPS-460AA-1XXXX, GPS-460BA-1XXXX, GPS-420AAPower Supply 1XXXX, GPS-420BA-1XXXX, GPS-360AA-1XXXX, GPS360BA-1XXXX, where X may be any alphanumeric character or blank.

Withdrawn

Withdrawn

E131881A179-UL

File E131881 Index

Volume X7

Page 4

Date: 2012-07-03 E131881A180-UL E131881A181-UL E131881A183-UL E131881A184-UL E131881A186-UL E131881A192-UL E131881A193-UL E131881A194-UL

Switching DPS-400LB XX, 1-468-851-11, where X may be any Power Supply alphanumeric character or blank. Switching DPS-470AB XX, DPS-470AB-1 XX, where X may be 0-9, A-Z Power Supply or blank. Switching DPS-180QB XX, DPS-180SB XX, DPS-180QB-1 XX, DPSPower Supply 180SB-2 XX, where X may be any alphanumeric character or blank. Switching DPS-360DB XX (X can be 0-9, A-Z or Blank) Power Supply Power Supply DPS-700CB A, DPS-700CB XX where X might be any for builing-in alphanumeric character or blank. DC-DC DPS-1300AB-1 XX, DPS-1300AB-2 XX where X can be Power Supply alphanumeric or blank for building-in Switching DPS-250AB-4 XX, DPS-250AB-5 XX, DPS-250AB-5 BX, Power Supply where X may be any alphanumeric character or blank. Switching DPSN-470AP XX(First X=0-9, A, G-Z or blank; Second X=0-9, Power Supply A-Z or blank) DPSN-470AP BX, DPSN-470AP CX, DPSN-470AP DX and DPSN-470AP EX, DPSN-470AP FX (X= 0-9, A-Z or blank)

Withdrawn

Withdrawn Withdrawn

DPSN-470BP XX (X=0-9, A-Z or blank) Switching DPS-525CB-1 XX, DPS-525CB XX, AC-036 XX where X= 0-9, E131881Power Supply A-Z or blank. A195-UL Power DPS-340CB XX, X = 0-9, A-Z or blank E131881Supply, BuiltA196-UL In AC/DC (PS3) Power DPS-240FB XX, DPS-240FB-1 XX (X can be 0-9, A-Z or blank) E131881Supply, BuiltA197-UL In AC/DC (PS3) Switching DPS-525DB XX, where X can be 0-9, A-Z or blank E131881Power Supply A198-UL DC-DC DN48S3R330A, DN48S3R330-1 A, DN48S1210A, E131881Converter DN48S0525A, and DN48S1R516A A199-UL Switching DPS-230GB-1 XX, DPS-275JB XX, where X can be any E131881Power Supply alphanumeric character or blank. A201-UL Switching DPS-660AB XX, where X can be 0-9, A-Z or blank E131881Power Supply A202-UL DC-DC 12S1830XXXX (where X can be any alphanumeric, dash or E131881Converter blank) A205-UL Switching DPSN-66BP XX where X canbe any alphanumeric or blank E131881Power Supply A209-UL Switching DPS-65PB REV: XX (where X = 0-9, A-Z or blank) E131881Power Supply A212-UL Switching C8161-60031 E131881Power Supply A213-UL DC-DC Q48DVX1X2XXXX (where X1 may be 1R5 or 1R2 which E131881Converter represent the first output voltage; where X2 may be 33 which A215-UL represent the second output voltage), X may be any alphanumeric character or blank. Switching 1) DPSN-150BP XXX E131881Power Supply (First X=0-9, A-Z or blank; Scond X=A-Z or blank; Third X=0-9, A220-UL

Withdrawn

Withdrawn Withdrawn

File E131881 Index

Volume X7

Page 5

Date: 2012-07-03

A-Z or blank, include DPSN-150BP M, DPSN-150BP L, DPSN150BP Q, not include DPSN-150BP MXX, DPSN-150BP LXX, DPSN-150BP QXX) 2) DPSN-150BP MXX (First X=0-9; Second X= 0-9, A-Z or blank) 3) DPSN-150BP LXX (First X=0-9; Second X= 0-9, A-Z or blank) 4) DPSN-150BP QXX (First X=0-9; Second X= 0-9, A-Z or blank) Switching DPS-850AB XX, DPS-1200CB XX, DPS-1200EB XX, where E131881Power Supply the X can be 0-9, A-Z or blank. A222-UL Switching DPSN-570AB XX and DPSN-570AP XX, where X canbe any E131881Power Supply alphanumeris or blank. A223-UL Switchinh DPS-224BB XX, DPS-220CB XX (X = 0-9, A-Z or blank) E131881Power Supply A224-UL Switching DPS-400MB XX (X can be A-Z, 0-9 or blank) E131881Power Supply A226-UL DC-DC S36SAX1X2XXXX (X1 = 3R3; X2 = 08; X can be any E131881Converter alphanumeric, dash or blank) A227-UL Switching DPS-197AB XX, DPS-200PB-162 XX, (where X = 0-9, A-Z or E131881Power Supply blank) A228-UL Power Q48DR2R533XXXXX and Q48DR3R350XXXXX (where X = E131881Supply, Built- any alphanumeric, +, *, #, _, hyphen or blank ) A230-UL In DC/DC (PS4) Switching DPS-650BB XX where the X can be 0-9, A-Z or blank. E131881Power Supply A232-UL Open frame ADP-18AF E131881power supply A234-UL Switching DPS-1300BB XX where X canbe any alphanumeric or blank E131881Power Supply A241-UL Switching DPS-345AB XX, where X may be any alphanumeric character E131881Power Supply or blank. A242-UL DC-DC E48SX1R240YYYY, where Y may be any alphanumeric, blank E131881Converter or dash. A244-UL Switching DPSN-100CP XX, where 1st X = 0-9, A-Z or Blank except E. E131881Power Supply 2nd X= 0-9, A-Z or Blank, DPSN-100CP EX, where X = 0-9, A- A248-UL Z or Blank Switching DPS-410DB XX (X can be 0-9, A-Z or blank) E131881Power Supply A249-UL Switching DPS-180MB-2 XX (X can be 0-9, A-Z or blank) E131881Power Supply A250-UL Switching DPS-450EB XX, where X may be any alphanumeric character E131881Power Supply or blank (for marketing purpose and no impact safety related A251-UL critical components and constructions) Switching DPS-180RB XX and DPS-180SB-1 XX, where X may be any E131881Power Supply alphanumeric character or blank. A253-UL DC-DC D48S1210-3 XX, D48S1210-5 XX (X = 0-9, A-Z or blank) E131881Converter A254-UL Switching DPSN-125CP XX, where X may be any alphanumeric E131881Power Supply character or blank. A255-UL DC-DC 12S1575H-XX,where X may be any alphanumeric character or E131881-

Withdrawn

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 6

Date: 2012-07-03

Converter blank. A256-UL DC-DC P12S13100BXXX,where X may be any alphanumeric character E131881Converter or blank. A262-UL Switching DPSN-550AP XX (1st X=0-9, A-Z or blank, except C; 2nd X=0- E131881Power Supply 9, A-Z or blank) and DPSN-550AP CX (X=0-9, A-Z or blank) A263-UL DC-DC 12S1385XXX (where X= 0-9, A-Z or blank) E131881Converter A265-UL Switching DPS-300AB-5 XX, DPS-300AB-6 XX, DPS-350AB-2 XX, DPS- E131881Power Supply 350AB-3 XX, GPS-300DN-1XXXX, GPS-300DB-1XXXX, GPS- A267-UL 300DC-1XXXX, GPS-350EN-1XXXX, GPS-350EB-1XXXX, GPS-350EC-1XXXX and DPS-400RB XX (X can be 0-9,A-Z or Blank). Switching DPS-190DP XX, where X may be any alphanumeric character E131881Power Supply or blank. A268-UL Switching EADP-43AF A E131881Power Supply A270-UL Switching DPS-218AB XX, where X may be any alphanumeric character E131881Power Supply or blank. A271-UL DC-DC - Models IPM12SX1X2X3 X4, IPM12CX1X2X3 X4; where X1 = E131881Converter 0A0, 0R8, 0R9, 1R0, 1R2, 1R5, 1R8, 2R5, 3R3 or 050 (Output A273-UL Voltage); X2 = R or S (Type of I/O Pins); X3 = 04, 06 or 08 (Output Current); X4 = A (Option Code). - Models IPM04SX1X2X3 X4, IPM04CX1X2X3 X4; where X1 = 0A0, 0R8, 0R9, 1R0, 1R2, 1R5, 1R8, 2R5, 3R3 or 050 (Output Voltage); X2 = R or S (Type of I/O Pins); X3 = 04, 06, 08 or 10 (Output Current); X4 = A (Option Code). Switching - DPSN-60CP XX (1st X=0-9, A-Z or blank, except C; 2nd X=0- E131881Power Supply 9, A-Z or blank) A274-UL - DPSN-60CP CX (X=0-9, A-Z or blank) Model S48SRX1X2XXXX (X1=3R3, X2=03 or 04; X1=1R8, X2=05; X1=2R5, X2=04; X1=050, X2=02 or 03; X1=120, X2=01; X1=070, X2=02; X1=100, X2=01; X= alphanumeric character, +, *, #, _ , hyphen or blank) DPS-1570AB XX, where X may be 0-9, A-Z or Blank

Withdrawn

DC to DC Converter

E131881A275-UL

Switching Power Supply Switching DSP-250AB-6 XX, X=0-9, A-Z or blank. Power Supply Switching 1) GPS-450AA-1XXXX, GPS-400AA-1XXXX, A-45GA, APower Supply 40GA, and HH-500WATA, ECP-450AAB A. 2) GPS-350DA-1XXXX (X can be 0-9, A-Z or blank). 3) DPS-400SB XX (X can be 0-9,A-Z or Blank) 4) DPS-400TB XX (X can be 0-9,A-Z or Blank) DC-DC NC12SX1X230XXXXX, NC12SX1X240XXXXX Converter (X1 = 1R2, 1R5, 1R8, 2R5, 3R3, 050 or 0A0; X2 = H or V; X = any alphanumeric characters, +, *, #, _, hyphen or blank) Power Supply DPS-400LB-1 XX where X can be any alphanumeric character or blank. Switching DPS-300AB-9 XX (X can be 0-9, A-Z or blank) Power Supply Switching 341-0015-XX, where X is any alphanumeric character or blank Power Supply DC-DC DNLX1X2X3X4X5X6X7X, DNMX1X2X3X4X5X6X7X, Converter DNSX1X2X3X4X5X6X7X, BSTX1X2X3X4X5X6X7X (the

E131881A277-UL E131881A278-UL E131881A284-UL

Withdrawn

E131881A289-UL E131881A290-UL E131881A294-UL E131881A297-UL E131881A299-UL

File E131881 Index

Volume X7

Page 7

Date: 2012-07-03

Switching E131881Power Supply A300-UL Switching DPS-460CB XX, DPS-475BB XX where X may be any E131881Power Supply alphanumeric character or blank; for marketing purpose and no A307-UL impact any safety related components and constructions. Other DPS-350AB-4 XX and DPS-350AB-4 BX, where X may be any E131881alphanumeric character or blank. A314-UL Power Supply DPS-700FB XX, DPS-700FB-1 XX, where X can be any E131881alphanumeric character or blank. A315-UL Power Supply DPS-2500AB XX where X can be any alphanumeric character E131881or blank. A317-UL Switching DPS-520BB XX (Power Supply Unit) E131881Power Supply A318-UL for building-in AC-042 XX (Back Plane Unit) where 'X' may be any alphanumeric character or blank. Switching DPS-350TB-1 XX (X=0-9, A-Z or blank) Power Supply Switching DPS-775AB XX (X can be 0-9, A-Z or blank) Power Supply Switching DPS-400MB-1 XX, DPS-400AB-9 XX (X = 0-9, A-Z or blank) Power Supply Switching (1) DPS-310CB XX, Power Supply (2) DPS-230HB XX. (X = 0-9, A-Z or blank) DC-DC NC12SX1X220XX XXX and NC12SX1X215XX X XX( (X1 = Converter 1R2, 1R5, 1R8, 2R5, 3R3, 050 or 0A0; X2 = H or V; X= any alphanumeric characters, +, *, #, _, hyphen or blank) Switching EADP-58BF A Power Supply Switching DPS-530AB XX (X can be 0-9, A-Z or blank) Power Supply DC-DC E48SXX1X2YYYY Converter (where X1 can be 050, 1R2, 1R8, 2R5 and 3R3; X2 can be 01 to 15 for X1=050, 01 to 40 for X1=1R2, 01 to 30 for X1=1R8 and 01 to 20 for X1=2R5 or 3R3; Y can be any alphanumeric, blank or dash) Power Supply DPS-250AB-8 XX for build-in DC to DC S48SEX1X2XXXX, where Converter X1 can be 150, 120, 050 or 3R3 to denote output voltage, X2 can be 01, 03 or 05 to denote output current, where XXXX can be any alphanumeric, +,-, *, #, _, hyphen or blank. DC-DC Q48DW3R3X2XXX(X2=12, 15 or 18; X=any alphanumeric Converter character, +, *, #, _,hyphen), Q48DW3R315NRFD DC-DC S48SPX1X2XXXX (X1=050, X2=07; X1=120, X2=03; X1=3R3, Converter X2=10 , X= alphanumeric character, +, *, #, _, hyphen or blank) DC-DC E48SBX1X2XXXX (X1 = 120, X2 = 20 or X1 = 9R6, X2 = 25; X Converter = any alphanumeric characters, +, *, #, _, hyphen or blank), Switching DPS-600RB XX , DPS-600TB XX (where X=0-9, A-Z or Blank) Power Supply

definitions of X1, X2, X3, X4, X5, X6, X7 and X, See Enclosures/Miscellaneous for details) DPS-433AP XX, where X can be 0-9, A-Z or blank.

Withdrawn

Withdrawn

E131881A321-UL E131881A323-UL E131881A325-UL E131881A327-UL E131881A328-UL E131881A331-UL E131881A332-UL E131881A335-UL

Withdrawn

E131881A337-UL E131881A339-UL

Withdrawn

E131881A342-UL E131881A346-UL

E131881A347-UL E131881A351-UL

File E131881 Index

Volume X7

Page 8

Date: 2012-07-03 E131881A353-UL E131881A357-UL E131881A358-UL E131881A361-UL E131881A362-UL E131881A365-UL E131881A367-UL

DC-DC Q48DB12003XXXXX (where X can be any alphanumeric Converter character, +, -, #, _, or blank) Switching DPS-275HB XX where X can be any alphanumeric character Power Supply or blank. DC-DC Q48SXX1X2XXXXX (X1=3R3, X2=35; X= alphanumeric Converter character, +, *, #, _, hyphen or blank) Power Supply DPSN-30BP XX, DPSN-20JP XX, EDPS-22AF XX (where X may be 0-9, A-Z or blank) Switching DPS-400QB XX, where X could be any alphanumeric or blank Power Supply Switching DPS-160AB DX and DPS-160AB FX, where "X" can be any Power Supply alphanumeric character or blank. DC-DC S24SAXYZZZZ, where X can be 120, 050, 3R3, 2R5, 1R8, Converter 1R5, 1R2; Y can be 03, 06, 10, 12; Z can be any alphanumeric character or blank. AC adaptor ADP-120ZB ABM

Withdrawn

Withdrawn

E131881A370-UL Switching GPS-350EB-2 XXXX and GPS-350EN-2 XXXX (X can be 0-9, E131881Power Supply A-Z or blank) A375-UL DC-DC Q48DRX1X2XXXX (where X1 = 1R8, 1R5 or 1R2, X2 = 33, X E131881Converter = any alphanumeric character, +, -, *, #, _, blank or dash) A376-UL Switching DPS-600RB-1 XX combined with AC-044 XX, where X=0-9, A- E131881Power Supply Z, or Blank; DPS-600TB-1 XX combined with AC-077 XX, A377-UL where X can be any alphanumeric or blank Switching DPS-250AB-12 XX (where X could be any alphanumeric or E131881Power Supply blank) A378-UL Switching EADP-15BF A E131881Power Supply A379-UL Switching EADP-35AF A E131881Power Supply A380-UL Switching DPS-290AB XX (where X could be any alphanumeric or blank) E131881Power Supply A381-UL Switching EADP-45AF B E131881Power Supply A383-UL Switching DPS-275GB-1 XX, DPS-275GB-2 XX (where X could be any E131881Power Supply alphanumeric or blank) A384-UL Switching DPSN-26BP-2 XX E131881Power Supply A385-UL DC-DC L36SAX1X2XXXX (Where are X1X2=05010, 12004 or 3R315; E131881Converter X=0-9, A-Z, +, -, *, _, # or Blank) A387-UL Power Supply DPS-350AB-6 XX (X = 0-9, A-Z or blank) E131881A388-UL Switching GPS-400BB-1XXXX, where X may be any alphanumeric E131881Power Supply character or blank. A390-UL Switching DPS-108DB-1 XX, DPS-108DB XX (X = 0-9, A-Z or blank) E131881Power Supply A391-UL Switching DPS-350AB-7 xx, DPS-350AB-8 xx, DPS-350VB xx, DPSE131881Power Supply 350VB-1 xx, DPS-360FB xx, DPS-360FB-1 xx (where x may A392-UL be any alphanumeric character or blank.) Switching DPS-370AB XX and DPS-370AB-1 XX (X = 0-9, A-Z or blank) E131881Power Supply A393-UL Switching ADP-30GF A E131881Power Supply A394-UL Switching GPS-400BB-1XXXX, where X may be any alphanumeric E131881Power Supply character or blank. A395-UL

Withdrawn

Withdrawn Withdrawn

Withdrawn Withdrawn

Withdrawn Withdrawn Withdrawn

File E131881 Index

Volume X7

Page 9

Date: 2012-07-03 E131881A397-UL E131881A398-UL E131881A401-UL E131881A405-UL E131881A407-UL E131881A409-UL E131881A410-UL

Switching EADP-64AF B, EADP-64BF B, EADP-64CF B Power Supply Switching DPS-180KB-7 XX, DPS-220DB XX (where X could be any Power Supply alphanumeric or blank) Switching EADP-19AF A, EADP-18EF A Power Supply Switching DPS-140JB XX, DPS-148BB XX (X can be 0-9, A-Z or blank) Power Supply Switching DPS-220NB XX (where X can be 0-9, A-Z or blank) Power Supply Switching DPS-250AB-13 XX, where X can be 0-9, a-z, A-Z or blank. Power Supply Switching - For Power supply unit: Power Supply DPS-670CB XX, D670P-SX, DPS-650GB XX - For Back-plane unit with DPS-650GB XX: AC-053 XX (X = 0-9, A-Z or blank) Switching DPS-120CB XX, where X can be any alphanumeric character Power Supply or blank. Switching DPSN-50EB XX (X = 0-9, A-Z or blank for marketing purpose Power Supply and no impact safety related critical components and constructions.) Switching DPS-460DB-1 XX (X = 0-9, A-Z or blank) Power Supply Switching DPS-710BB XX (X = 0-9, A-Z or blank) Power Supply Switching DPS-110AB-1 XX (X = 0-9, A-Z or blank) Power Supply Switching OPS-200PB-159 XX (X = A-Z, 0-9 or blank) Power Supply Power Supply DPS-250AB-16 XX, DPS-250AB-15 XX, DPS-300AB-21 XX (where X could be 0-9, A-Z or blank for marketing purpose and no impact safety related critical components and constructions.) Power Supply GPS-300EA-1XXXX, GPS-300AA XX (X=0-9, A-Z or blank)

Withdrawn

Withdrawn

E131881A414-UL E131881A419-UL E131881A423-UL E131881A426-UL E131881A427-UL E131881A429-UL E131881A430-UL

Withdrawn

Withdrawn Withdrawn

E131881A432-UL Switching DPS-800GB XX (X = 0-9, A-Z or blank) E131881Power Supply A433-UL Switching DPS-450JB XX (X = 0-9, A-Z or blank, except B for first letter), E131881Power Supply DPS-450JB BX (X = 0-9, A-Z or blank) A436-UL Switching GPS-300AB Ax, GPS-300AB Bx, GPS-300AB Cx, GPS-300AB E131881Power Supply Dx, GPS-300CB Ax, GPS-350AB Ax, GPS-350AB Bx, GPSA438-UL 350AB Cx, GPS-350AB Dx, GPS-350AB Gx, GPS-350AB Hx, GPS-350BB Ax, GPS-400AB Bx, GPS-400AB Cx, ECP-400AB C, GPS-400AB Dx, GE-C300P-Ax, GE-C300N-Ax, GE-C300PCx, GE-C300N-Cx, GE-C350P-Ax, GE-C350N-Ax, GE-C350PCx, GE-C350N-Cx, GE-C400P-Ax, GE-C400N-Ax, GE-C400PCx, GE-C400N-Cx, HH-400EBEA, HH-400EBTA, HH400UNEA, HH-450EBEA, HH-450EBTA, HH-450UNEA, Litepower 400NP, Litepower 400PP, HH-400UNTA, HH450UNTA and AGI-U350HH (x can be 0-9,A-Z or Blank), LN-

File E131881 Index

Volume X7

Page 10

Date: 2012-07-03

350D, GPS-350CB XX ( X can be 0-9,A-Z or Blank) Switching (1) DPS-460DB BX, DPS-460DB XX (X = 0-9, A-Z or blank and E131881Power Supply the first X of DPS-460DB XX could not be B). A439-UL (2) DPS-460DB-2 XX, DPS-460DB-6 XX (Where X can be any alphanumeric or blank) (3) DPS-460DB-3 XX (Where X can be any alphanumeric or blank) (4) DPS-460DB-4 XX (Where X can be any alphanumeric or blank) (5) D460AD-00 Switching DPS-300AB-8 XX (X = 0-9, A-Z or blank) Power Supply Switching GPS-500AB XX, A-50GA1, ENP-500AAB XX, P-50GA, GPSPower Supply 550AB XX, A-55GA1, ENP-550AAB XX, P-55GA (where X can be 0-9,A-Z or Blank) DC-DC F48SAX1X2XXXXX, F24SAX1X2XXXXX (where X1 = 280, Converter X2=25; X = any alphanumeric, +, *, #, _, hyphen or blank) Switching DPS-700GB XX (where X could be any alphanumeric or blank) Power Supply Power Supply DPS-300AB-14 XX (where X could be 0-9, A-Z or blank) Switching DPS-250AB-18 XX, DPS-250AB-25 XX, DPS-250AB-28 XX, Power Supply CTN-200AE X (X = 0-9, A-Z or blank), ECP-250RC A, ECP250RCN A, ECP-300CTF B and ECP-300CTFN B. Switching DPSN-125DB XX (X= 0-9, A-Z or blank) Power Supply Switching D488P-SX, DPS-488AB XX (X = 0-9, A-Z or blank) Power Supply Switching DPS-204AB XX (X = 0-9, A-Z or blank) Power Supply Switching DPSN-210CB XX (X= 0-9, A-Z or blank) Power Supply Switching EADP-36AF B Power Supply Switching DPS-326AB XX (X can be 0-9, A-Z or blank) Power Supply Switching DPS-670BB XX (X=A-Z , 0-9 or blank) Power Supply Switching DPS-1400AB XX (X = A-Z, 0-9 or blank) Power Supply Switching D800P-SX, DPS-800JB XX (X=A-Z, 0-9 or blank) Power Supply Open frame EADP-17AF A power supply Switching N305N-05, N305P-05 Power Supply Switching DPS-350NB XX Power Supply (X=0-9, A-Z or blank but not B and C); DPS-350NB BX, DPS-350NB CX and DPS-350NB-1 XX (X=0-9, A-Z or blank)

E131881A440-UL E131881A449-UL E131881A454-UL E131881A455-UL E131881A458-UL E131881A460-UL E131881A463-UL E131881A470-UL E131881A471-UL E131881A472-UL E131881A473-UL E131881A475-UL E131881A479-UL E131881A481-UL E131881A482-UL E131881A486-UL E131881A487-UL E131881A490-UL

Withdrawn

Withdrawn

Withdrawn Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 11

Date: 2012-07-03 E131881A491-UL E131881A492-UL

Power Supply DPS-300AB-16 XX (where X could be 0-9, A-Z or blank) Switching DPS-350NB XX Power Supply (X=0-9, A-Z or blank but not B and C); DPS-350NB BX, DPS-350NB CX and DPS-350NB-1 XX (X=0-9, A-Z or blank) Power Supply DPS-600GB-1 XX (X = 0-9, A-Z or blank)

Withdrawn

E131881A495-UL Switching DPS-240FB-2 XX, DPS-240MB XX (X can be 0-9, A-Z or E131881Power Supply Blank) A498-UL Switching N275P-01 E131881Power Supply A500-UL Switching DPS-575AB XX (X = 0-9, A-Z or blank) E131881Power Supply A502-UL Switching N220P-02 E131881Power Supply A503-UL Switching DPS-220PB xx, where x can be 0-9, A-Z or blank. E131881Power Supply A507-UL Switching DPS-750DB XX, DPS-700KB XX, DPS-750DB-1 XX (X = 0-9, E131881Power Supply A-Z or blank) A510-UL Accessory - DPS-310HB XX, DPS-310HB-2 XX, DPS-230JB XX, DPSE131881Switching 230JB-2 XX (where X could be 0-9, A-Z or blank or marketing A518-UL Power Supply purpose and no impact safety related critical components and constructions.) Switching DPS-650FB XX (X can be any alphanumeric or blank) E131881Power Supply A520-UL Switching DPS-240HB XX, DPS-240HB-1 XX (X=0-9, A-Z or Blank) E131881Power Supply A521-UL Switching DPS-300VB XX, DPS-300VB-1 XX, DPS-300AB-35 XX and E131881Power Supply DPS-300AB-36 XX (where X can be 0-9, A-Z or blank) A522-UL Switching DPS-250AB-19 XX, DPS-250AB-19 BX, DPS-250AB-19 CX, E131881Power Supply DPS-250AB-19 EX (Where X can be any alphanumeric or A525-UL blank, the first X of DPS-250AB-19XX shall not be B or C or E) Power Supply DPS-300AB-19 XX, DPS-300AB-24 XX, DPS-300AB-25 XX, E131881for building-in DPS-300AB-26 XX, DPS-300AB-27 XX (where X could be 0- A529-UL 9, A-Z or blank) Switching EADP-102AF B E131881Power Supply A530-UL Switching (1) DPS-310CB XX, E131881Power Supply (2) DPS-230HB XX. A533-UL (X = 0-9, A-Z or blank) Switching DPS-250AB-22 XX, DPS-250AB-22 AX (Where X can be any E131881Power Supply alphanumeric or blank, except A for first X of model DPSA534-UL 250AB-22 XX) DPS-250AB-63 XX (Where X can be any alphanumeric or blank) EADP-59AF B

Withdrawn

Withdrawn

Switching Power Supply Switching - For Power supply unit: Power Supply DPS-650JB XX DPS-770AB XX

E131881A535-UL E131881A536-UL

File E131881 Index

Volume X7

Page 12

Date: 2012-07-03

(X = 0-9, A-Z or blank) Switching DPS-450LB XX, DPS-450LB BX (X = 0-9, A-Z or blank) Power Supply Switching DPSN-100MP XX (X can be any alphanumeric character or Power Supply blank, but first X excluding B, C and D); DPSN-100MP BX, DPSN-100MP CX, DPSN-100MP DX ((X can be any alphanumeric character or blank) DC-DC EADP-102BF A, EADP-102BF CX and EADP-102BF DX Converter Switching NPS-300CB XX (X can be 0-9, A-Z or blank) Power Supply Switching DPS-980AB BX, DPS-980AB XX, DPS-980BB XX (X = 0-9, APower Supply Z or blank, the first X of Model DPS-980AB XX can not be B) Power Supply DPS-650HB XX (X can be any alphanumeric or blank) E131881A539-UL E131881A540-UL Withdrawn

E131881A541-UL E131881A542-UL E131881A544-UL E131881A545-UL Switching DPS-210FB XX and DPS-210GB XX, where X can be 0-9, A-Z E131881Power Supply or blank. A553-UL Switching DPS-280DB XX, D280P-00, DPS-280DB BX, D280N-00 E131881Power Supply (where X=A-Z, 0-9 or blank, except B for the first X of model A555-UL DPS-280DB XX.) Switching EADP-30AF B E131881Power Supply A556-UL Switching DPS-1200GB XX, HSTNS-PD10 E131881Power Supply A564-UL Switching RPS-650X1X2 XX (Power Cage) with DPS-650EB XX (Power E131881Power Supply Module) A565-UL (X1 can be dash or blank; X2 can be 0-99, A-Z or blank; X can be any alphanumeric or blank.) Switching RPS-430 XX (Power Cage) Power Supply DPS-430DB XX (Power Module) (X=A-Z, 0-9 or blank) Switching DPS-330DB XX (where X can be 0-9, A-Z or blank for Power Supply marketing purpose and no impact safety related critical components and constructions.) Switching - For Power supply unit: Power Supply DPS-450KB XX (X = 0-9, A-Z or blank) DPS-230KB XX (X=0-9, A-Z or Blank) E131881A567-UL

Withdrawn

Withdrawn

E131881A572-UL E131881A573-UL

Switching Power Supply Switching DPS-135DP XX (X=0-9, A-Z or blank) Power Supply Switching D275P-00, DPS-275CB-1 XX, where X can be 0-9, A-Z or Power Supply blank. Switching DPS-350AB-4 XX, DPS-350AB-4 BX and GPS-350FB-1XXXX, Power Supply where X may be any alphanumeric character or blank and the firxt X of Model DPS-350AB-4 XX can not be B. Switching GPS-650AB XX, ENP-650AAB XX, CFT-650-12X, GPS-650APower Supply 12X, CFT-650A-12X, U-65GA (X can be 0-9,A-Z or Blank) Switching DPS-250AB-24 XX (Where X can be any alphanumeric or

E131881A582-UL E131881A583-UL E131881A586-UL E131881A588-UL E131881A596-UL E131881-

Withdrawn

File E131881 Index

Volume X7

Page 13

Date: 2012-07-03 A599-UL E131881A600-UL E131881A601-UL E131881A603-UL E131881A605-UL E131881A606-UL E131881A609-UL E131881A614-UL E131881A615-UL

Power Supply blank) Switching DPS-275LB XX, where X can be 0-9, A-Z or blank. Power Supply Switching DPS-210EP-2 XX, where X=0-9, A-Z or Blank. Power Supply Switching SADP-185AF B Power Supply Switching DPS-300AB-17 XX, DPS-300AB-32 XX (X can be 0-9, A-Z, or Power Supply Blank) Switching DPS-160QB XX (X=0-9, A-Z or Blank) Power Supply Switching DPS-300AB-23 XX (The symbols "X" in type designation can Power Supply be 0-9, A-Z or blank, for marketing use only) Switching GPS-350GB XX, GPS-350GB-1 XX (X = 0-9, A-Z or blank) Power Supply DC-DC S48SWX1X2XXXXX (X1=050, X2=02 or 03; X1=3R3, X2=03; Converter X= alphanumeric character, +, *, #, _, hyphen or blank) S36SSX1X2XXXXX (X1=3R3, X2=04; X= alphanumeric character, +, *, #, _, hyphen or blank)

Withdrawn

S48SSX1X2XXXXX (X1=1R8, X2=05; X1=2R5, X2=04; X1=3R3, X =03 or 04; X1=050, X2=02 or 03; X1=120, X2=01; X= alphanumeric character, +, *, #, _, hyphen or blank) Switching DPS-160QB-1 XX and DPS-180XB XX (X=0~9, A-Z or a-z) E131881Power Supply A616-UL Switching N375E-00, N375E-01 E131881Power Supply A620-UL Switching N305E-00 E131881Power Supply A621-UL Switching DPS-240MB-1 XX (X can be 0-9, A-Z or blank) E131881Power Supply A625-UL Switching DPS-575BB XX (X = 0-9, A-Z or blank) E131881Power Supply A628-UL Power Supply DPS-1000DB XX (X = 0-9, A-Z or blank) E131881A637-UL Switching N305P-06 E131881Power Supply A638-UL Switching DPS-1570BB XX, DPS-1570CB XX, D1570P-S0 (X= 0-9, A-Z, E131881Power Supply OR BLANK) A641-UL AC Adapter DA230PS0-00, DA210PE1-00 E131881A642-UL Switching DPS-196BP XX (X = 0-9, A-Z or blank) E131881Power Supply A649-UL Switching NPS-300DB XX (X can be 0-9, A-Z, a-z or Blank) E131881Power Supply A655-UL Switching DPS-650MB XX (X can be any alphanumeric or blank) E131881Power Supply A657-UL Switching DPS-300AB-18 XX (X = 0-9, A-Z or blank) E131881Power Supply A660-UL Switching DPS-650LB XX (X=0-9, A, C-Z, a-z or Blank, for marketing E131881Power Supply purpose and no impact any safety related constructions and A666-UL components) DPS-650LB BX(X=0-9, A-Z, a-z or Blank, for marketing

Withdrawn

File E131881 Index

Volume X7

Page 14

Date: 2012-07-03

purpose and no impact any safety related constructions and components) Switching DPS-300AB-20 XX, DPS-300AB-31 XX and DPS-300AB-50 E131881Power Supply XX (where X could be 0-9, A-Z or blank) A667-UL Switching N525E-00 E131881Power Supply A668-UL Switching DPS-1520AB XX E131881Power Supply A669-UL Switching GPS-200BB XX, DPS-180KB-10 XX (X can be 0-9, A-Z or E131881Power Supply Blank). A670-UL Switching DPS-475CB XX, DPS-475CB-1 XX (X=0-9, A-Z, a-z or Blank E131881Power Supply for marketing purpose only, not imapct safety related) A672-UL Switching GPS-200AB XX, GPS-200CB XX, DPS-150TB XX (X can be 0- E131881Power Supply 9, A-Z or blank) A673-UL Switching DPS-1200FB XX, DPS-1200KB XX, DPS-1200 LB XX (X can b E131881Power Supply any alphanumeric or blank) (HP RMN: HSTNS-PD11) A675-UL Switching DPS-230GB-2 XX (X can be any alphanumeric or blank or E131881Power Supply marketing purpose and no impact safety related critical A676-UL components and constructions.) Power Supply DPS-225MB XX, where X could be 0-9, A-Z, a-z or blank Switching DPS-102JP XX (X=0-9, A-Z or blank) Power Supply Switching DPS-280GB XX (where X can be A-Z, 0-9 or blank) Power Supply Switching DPS-200PP-164 XX, DPS-220WB XX (X=0-9, A-Z, a-z, or Power Supply blank) Switching N875E-00 Power Supply Switching DPS-750GB-1 XX (X can be any alphanumeric or blank), Power Supply HSTNS-PD12 Power Supply EADP-300AB Power Supply DPS-400AB-1 XX and DPS-350WB XX (X=0-9, A-Z or blank). E131881A677-UL E131881A679-UL E131881A681-UL E131881A683-UL E131881A684-UL E131881A685-UL E131881A689-UL E131881A690-UL E131881A691-UL E131881A693-UL E131881A694-UL E131881A695-UL E131881A696-UL E131881A697-UL E131881A699-UL E131881A702-UL Withdrawn

Withdrawn

Withdrawn

Switching DPS-835AB XX (X can be any alphanumeric or blank) Power Supply Switching DPS-220SB XX, where X could be 0-9, A-Z, a-z or blank Power Supply Switching EADP-39BF B Power Supply Switching DPS-1000EB XX (The "X" can be 0-9, A-Z or blank) Power Supply DPS-1000HB XX (The "X" can be 0-9, A-Z or blank) Switching GPS-750AB xx, CFT-750A-14x, ECP-750AAB xx, U-75HA (X Power Supply can be 0-9, A-Z or Blank) Switching D400P-00, DPS-400YB XX, DPS-400YB-2 XX, DPS-400YB-3 Power Supply XX (X can be any alphanumeric or blank) Switching DPS-160HB XX (X=0~9, A-Z or blank) Power Supply Switching DPS-300AB-28 XX, DPS-300AB-29 XX, DPS-300AB-39 XX, Power Supply GPS-300AB-1 XX, ECP-300RCE A, GPS300AB, CAA-350AE A, CAA-350AT A, DPS-350AB-16 XX, GPS-350HB XX, where X could be 0-9, A-Z, a-z or blank Switching DPS-250AB-27 XX, where X could be 0-9, A-Z, a-z or blank E131881-

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 15

Date: 2012-07-03

Power Supply A704-UL Switching DPS-650PB XX (X can be 0-9, A-Z or blank) E131881Power Supply A707-UL Switching PWS-501-PF, DPS-500MB XX, where X could be 0-9, A-Z, a-z E131881Power Supply or blank A709-UL Switching DPS-800LB XX (X=0-9, A-Z, a-z or Blank; for marketing E131881Power Supply purpose and no impact safety related critical components and A710-UL constructions) Switching D528P-00, D675P-S0 E131881Power Supply A712-UL Switching GPS-250AB XX (The "X" can be 0-9, A-Z or blank) E131881Power Supply A718-UL Switching ECP-400RC A, ECP-400RC B, ECP-450CATX B, ATX-450Y, E131881Power Supply A-40GA, LP-450AL2ND, GPS-400BB-1 xx, GPS-400BB xx (x A719-UL can be 0-9, A-Z or Blank), GPS-350A. Switching D670P-S1 E131881Power Supply A721-UL DC-DC AC-064 XX (X can be any alphanumeric or blank) E131881Converter A722-UL Switching N490P-00 E131881Power Supply A723-UL Switching DPS-350UB XX (X can be alphanumeric or blank) E131881Power Supply A724-UL Power DPS-150LP XX and DPSN-150HP XX (where "X" is any E131881Supply, Built- alphanumeric character or blank) A726-UL In AC/DC Switching DPS-750HB XX (X can be any alphanumeric or blank) E131881power supply A729-UL Switching DPS-1050CB XX (X can be any alphanumeric or blank) E131881power supply A731-UL Switching EADP-45FF B E131881Power Supply A733-UL Switching N1000E-01 E131881Power Supply A734-UL Switching D650P-S0 E131881power supply A736-UL Switching D750E-00, DPS-750LB XX (X=0-9, A-Z or blank.) E131881Power Supply A737-UL Switching DPS-1000GB XX (X can be 0-9, A-Z or blank) E131881power supply A738-UL Switching EADP-152CF A E131881Power Supply A741-UL Switching DPS-850CB XX (where X can be A-Z, 0-9 or blank), PWS-865- E131881Power Supply PQ A742-UL Switching D400P-01, DPS-400YB-1 XX (X can be any alphanumeric or E131881Power Supply blank.) A743-UL DC-DC AC-071 XX (X can be any alphanumeric or blank) E131881Converter A744-UL Switching DPSN-235AP XX (where X can be 0-9, A-Z or blank for E131881Power Supply marketing purpose and no impact safety related critical A745-UL components and constructions.), TDPS-235AB A Switching DPSN-350CB XX, DPSN-350CB AX (Where X= 0-9, A-Z or E131881Power Supply blank) A748-UL Switching DPS-900BB XX, DPS-900BB-1 XX (where X can be A-Z, 0-9 E131881Power Supply or blank) A750-UL

Withdrawn Withdrawn

Withdrawn

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 16

Date: 2012-07-03

Switching DPS-1000FB XX (X can be any alphanumeric or blank) power supply Switching DPS-300AB-30 XX (X can be 0-9, A-Z, or blank.) Power Supply Power Supply EADP-260AB

E131881A751-UL E131881A754-UL E131881A756-UL Switching D485P-S0 E131881Power Supply A758-UL Switching DPS-255AB XX (X=0-9,A-Z or blank) E131881power supply A759-UL Switching DPS-700MB XX, (X can be 0-9, A-Z or Blank) E131881Power Supply A768-UL Switching N750P-S1, N700P-S0 E131881power supply A770-UL Switching GPS-1000AB XX (X=0-9, A- Z or blank, first X can not be B, for E131881Power Supply marketing purpose and no impact any safety related A773-UL constructions and components) G-1000HA CFT-1000A-14B, GPS-1000AB A ECP-1000AAB A GPS-1000AB BX (X=0-9, A-Z or blank, for marketing purpose and no impact any safety related constructions and components) GPS-850CB XX (X=0-9, A- Z or blank, first X can not be B, for marketing purpose and no impact any safety related constructions and components), G-850HA, CFT-850A-14B, ECP-850AAB A and IP-I850A-BBAA. Switching DPS-200PB-167 XX, DPS-200PB-174 XX Power Supply (Where X can be 0-9, A-Z, or blank, and no impact safety related constructions and critical components.) Switching DPS-300AB-34 XX (X=0-9, A-Z or blank) Power Supply Switching EADP-245AB B Power Supply DC-DC ND12S0A0X1X2XXXXX (where X1=V, X2=40, X=any Converter alphanumeric, +, *, #, _, hyphen or blank) Switching DPS-82AP XX (X=0-9,A-Z or blank) Power Supply Switching DPS-230LB DX (X can be 0-9, A-Z, or blank.) Power Supply Switching D255P-00 Power Supply Power TEPDB1219 Distribution Board Switching DPS-240MB-3 XX (X = 0-9, A-Z or blank) Power Supply DC/DC EADP-3AF A Converter Switching DPS-380CP XX (X=0-9, A-Z or blank, for marketing purpose Power Supply and no impact any safety related constructions and components)

Withdrawn

Withdrawn

E131881A774-UL E131881A776-UL E131881A778-UL E131881A779-UL E131881A780-UL E131881A781-UL E131881A782-UL E131881A784-UL E131881A786-UL E131881A788-UL E131881A789-UL

File E131881 Index

Volume X7

Page 17

Date: 2012-07-03 E131881A791-UL

Switching (1) DPS-220UB XX Power Supply (2) DPS-250AB-41 XX (3) DPS-220UB-3 XX (X can be 0-9, A-Z or blank.) Switching EADP-170AB B Power Supply Switching DPS-250AB-36 XX (X can be any alphanumeric or blank) power supply Switching DPS-180KB-11 XX, DPS-180KB-12 XX, and DPS-180KB-13 Power Supply XX (X can be 0-9, A-Z, or blank.) Switching DPSN-300DB-1 XX (X=0-9, A-Z or blank) Power Supply Switching DPS-250AB-35 XX (X can be 0-9, A-Z or Blank) power supply Switching DPSN-300DB XX (X can be 0-9, A-Z or blank) Power Supply Switching DPS-365BB XX and DPS-420KB XX (X=0-9, A-Z or blank) power supply Switching D1570P-S1, DPS-1570DB XX (X can be any alphanumeric or Power Supply blank) Switching DPS-350XB yy, DPS-350XB-1 yy, DPS-350XB-2 yy, DPSPower Supply 350XB-3 yy, (y can be 0-9, A-Z, or blank.), D350PD-00, D350PM-01 Power Supply EADP-260BB

E131881A794-UL E131881A795-UL E131881A796-UL E131881A798-UL E131881A799-UL E131881A800-UL E131881A801-UL E131881A804-UL E131881A806-UL E131881A808-UL E131881A811-UL E131881A813-UL E131881A815-UL E131881A816-UL E131881A817-UL E131881A818-UL E131881A820-UL E131881A825-UL E131881A826-UL E131881A827-UL E131881A828-UL E131881A830-UL

Withdrawn

Switching N255PD-00 Power Supply Switching D50ED-00 Power Supply Switching NPS-175AB XX (X can be 0-9, A-Z or blank) Power Supply Switching D717P-S0 Power Supply Switching DPS-375CB XX (X can be any alphanumeric or blank) power supply Switching D235PD-00 power supply DC-DC DNL10S0A0R20XXX (where X = A-Z or blank) Converter Switching DPSN-350DB XX (X can be any alphanumeric or blank) Power Supply Switching DPS-125GB XX (X can be 0-9, A-Z, or blank.) Power Supply Switching N870P-S0 Power Supply Switching ADP-240BF B, ADP-240CF B Power Supply Switching DPS-200PB-168 XX (Where X can be any alphanumeric or Power Supply blank, for marketing purpose and no impact safety related critical components and constructions.) Switching DPS-250AB-38 XX, DPS-250AB-52 XX (X can be 0-9, A-Z, or E131881Power Supply blank.) A831-UL

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 18

Date: 2012-07-03

Switch Power DPS-2500BB XX (where X can be any alphanumeric or blank) E131881Supply A832-UL DC-DC DUS1235X (where X can be any alphanumeric or blank) E131881Converter A833-UL Switching ADP-360AF B E131881Power Supply A834-UL Switching TDPS-400BB XX, DPS-500NB XX (where XX represents any E131881Power Supply alphanumeric characters or blank) A835-UL Switching DPS-250AB-45 XX (X can be 0-9, A-Z or blank, for marketing E131881Power Supply purpose and no impact safety related critical components and A838-UL constructions.) Switching DPS-300AB-38 XX and DPS-400AB-3 XX (X can be 0-9, A-Z, E131881Power Supply or blank.) A839-UL Switching DPS-980CB XX (X can be any alphanumeric or black) E131881Power Supply A840-UL DC-DC Q48DC12003XXXX, Q48DB12003XXXX(X can be 0-9, A-Z or E131881Converter Blank) A842-UL DC-DC Q48DM3R312XXXX(X=0-9, A-Z or blank) E131881Converter A843-UL Switching DPS-800GB-1 XX, DPS-800GB-2 XX, DPS-800GB-3 XX, E131881Power Supply DPS-800GB-5 XX, DPS-800GB-4 XX (X can be 0-9, A-Z or A844-UL blank.) DC-DC E48SC05012XXXX, E48SC3R315XXXX, E48SC3R325XXXX, E131881Converter E48SC05015XXXX, E48SC3R320XXXX (Where X=0-9, A-Z, A846-UL or blank) Switching EADP-130AB XX (Where X can be any alphanumeric or black) E131881Power Supply A847-UL DC-DC DNQ12S0A0R25XXXX (where X = 0-9, A-Z or blank) E131881Converter A848-UL Switching DPS-650QB XX (X can be any alphanumeric or blank) E131881power supply A849-UL Switching DPS-200PB-169 XX (X=0-9, A-Z or blank, and no impact E131881Power Supply safety related constructions and critical components.) A850-UL Switching ADP-200CF B E131881Power Supply A851-UL DC-DC L48DB12001XXXX (X can be 0-9, A-Z or blank) E131881Converter A852-UL Switching DPS-500QB XX (X can be 0-9, A-Z, or blank.) E131881Power Supply A853-UL Switching DPS-750PB XX (X can be any alphanumeric or blank) E131881Power Supply A855-UL Switching DPS-725AB XX (X can be 0-9, A-Z, or blank.) E131881Power Supply A859-UL Switching DPS-220UB-2 XX and DPS-250AB-43 XX (X can be 0-9, A-Z, E131881Power Supply or blank.) A860-UL Switching DPS-460EB XX (X can be any alphanumeric or blank), E131881Power Supply HSTNS-PD14 A861-UL Switching EA-750 E131881Power Supply A862-UL Switching DPS-250AB-47 XX (X can be 0-9, A-Z, or blank.) E131881Power Supply A863-UL Switching DPS-200PP-170 XX (where X can be any alphanumeric or E131881Power Supply blank) A864-UL Switching DPS-250AB-44 XX, DPS-250AB-53 XX, DPS-250AB-50 XX, E131881Power Supply DPS-250AP-58 XX, DPS-200PB-177 XX (X can be 0-9, A-Z, or A865-UL

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 19

Date: 2012-07-03

blank.) Switching N875EF-00 E131881Power Supply A866-UL Switching DPS-350AB-10 XX (X can be 0-9, A-Z, or blank.) E131881Power Supply A870-UL DC-DC Q48DE3R315XXXX, Q48DE3R312XXXX, E131881Converter Q48DW3R315XXXX, Q48DW3R312XXXX (Where X=0-9, A-Z, A871-UL or blank, and no impact safety related constructions and critical components.) Switching DPS-850DB XX (Where X can be any alphanumeric or blank, E131881Power Supply and no impact safety related constructions and critical A872-UL components.) Switching N525EF-00 E131881Power Supply A873-UL Switching N1100EF-00 E131881Power Supply A875-UL Switching DPS-980BB-1 XX, DPS-980BB-2 XX (X can be any E131881Power Supply alphanumeric or blank) A876-UL Switching DPS-600SB XX (Where X can be any alphanumeric or blank) E131881Power Supply A877-UL Switching DPS-1050DB XX (Where X can be any alphanumeric or blank, E131881Power Supply and no impact safety related constructions and critical A878-UL components.) Switching DPS-700LB XX (X can be any alphanumeric or black) E131881Power Supply A879-UL Switching D525AF-00, D525AF-01 E131881Power Supply A880-UL Switching DPS-300AB-41 XX (X can be 0-9, A-Z, or blank.) E131881Power Supply A881-UL Switching DPS-250AB-39 XX (X can be 0-9, A-Z, or blank.), E131881Power Supply DPS-250AB-40 XX (X can be 0-9, A-Z, or blank.) A884-UL Switching DPS-300AB-42 XX, DPS-300AB-43 XX, DPS-300AB-58 XX E131881Power Supply (Where X can be 0-9, A-Z or blank) A885-UL Switching DPS-770BB XX (X can be any alphanumeric or black) E131881Power Supply A887-UL DC-DC DNM24S0B0R10XXX (X=0-9, A-Z, or Blank) E131881Converter A888-UL Switching DPS-180UB XX (Where X can be any alphanumeric or blank.) E131881Power Supply A890-UL DC-DC Q48SH12018XXXX, Q48SH12025XXXX, Q48SH12033XXXX E131881Converter (X can be 0-9, A-Z or blank, and no impact safety related A891-UL constructions and critical components) DC-DC H48SA53010XXXX, H48SA54010XXXX (X can be 0-9, A-Z or E131881Converter blank and for marketing purpose only, and no impact safety A892-UL related constructions and critical components.) DC-DC D48T72 A E131881Converter A895-UL Switching D480E-S0 E131881Power Supply A896-UL Switching PWS-665-PQ, DPS-665AB XX (X=0-9, A-Z or blank) E131881Power Supply A897-UL Switching D580E-S0, D400EF-S0 E131881Power Supply A898-UL Switching DPS-300AB-47 XX (X can be 0-9, A-Z, or blank.); DPS-300AB- E131881Power Supply 53 XX (X can be 0-9, A-Z, or blank); DPS-300AB-70 XX (X can A899-UL

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 20

Date: 2012-07-03

be 0-9, A-Z, or blank.). Switching EADP-100AF A, EADP-100AF C, EADP-100AF AB, EADPPower Supply 100AF CB Switching EDPS-60AF XX (X = 0-9, A-Z or blank) Power Supply Switching EDPS-60BF AB, EDPS-60BF XX (X = 0-9, A-Z or blank, Power Supply except for X=A or B) DC-DC V36SE12004XXXX, V48SE12004XXXX, V36SE3R315XXXX, Converter V48SE3R315XXXX, V36SE05010XXXX, V48SE05010XXXX (where X can be any alphanumeric or blank) Switching DPS-300AB-44 XX, DPS-250AB-48 XX, Power Supply DPS-280NB XX, DPS-350AB-13 XX, where X could be 0-9, AZ, a-z or blank. DC-DC AC-083 XX, AC-083-1 XX (X can be any alphanumeric or Converter blank) Switching D500E-S0, D400E-S0 Power Supply Switching DPS-250AB-49 XX (X can be 0-9, A-Z, or blank.) Power Supply DC-DC AC-082 XX, AC-085 XX (X can be any alphanumeric or blank) Converter Power Supply EADP-220BB

E131881A901-UL E131881A902-UL E131881A903-UL E131881A904-UL E131881A906-UL Withdrawn

E131881A912-UL E131881A913-UL E131881A914-UL E131881A915-UL E131881A917-UL Switching DPS-750NB XX, DPS-750SB XX, DPS-400AB-4 XX (where X E131881Power Supply can be any alphanumeric or blank) A918-UL Switching EADP-20BF XX (where X can be any alphanumeric or blank E131881Power Supply except C for first X), EADP-20BF CX (where X can be any A920-UL alphanumeric or blank) DC/DC 45W1494 E131881Adapter A923-UL Switching DPS-240SB XX (X = can be 0-9, A-Z or blank, and no impact E131881Power Supply safety related constructions and critical components.) A924-UL Switch Power DAC-19M001XXXXX, where X can be 0-9, A-Z or blank. E131881Supply with A925-UL D/A Inverter Power Supply DAC-32SP001 XX, X maybe 0-9, A-Z, or blank, for marketing E131881purpose and no impact safety related critical components and A926-UL constructions. Power Supply DAC-19M021XX E131881(Where X maybe 0-9, A-Z, blank or "-", and no impact safety A927-UL related constructions and critical components.) Power DAC-22P001XXXXX (X=0~9, A~Z, - or blank, and no impact E131881Supplies for safety related constructions and critical components.) A928-UL Information Technology Equipment Including Electrical Business Equipment Switching DPS-220AB-2 XX (where X can be 0-9, A-Z or blank) E131881Power Supply A929-UL Switching EDPS-645AB XX (where X can be any alphanumeric or blank) E131881Power Supply A931-UL Switching DPS-750RB XX(RMN:HSTNS-PD18) (where X can be any E131881-

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 21

Date: 2012-07-03

Power Supply alphanumeric or blank.) A934-UL Switching DPS-270EB XX, DPS-300AB-68 XX (X can be 0-9, A-Z or E131881Power Supply blank) A935-UL Switching DPS-250AB-51 XX, DPS-250AB-56 XX where X can be 0-9, A- E131881Power Supply Z or blank. A937-UL Switching NPS-250MB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A938-UL Switching CFA-150AF XX, CFA-100AF XX (Where X can be 0-9, A-Z or E131881Power Supply blank) A939-UL DC-DC D12S72XX (X=0-9, A-Z, or blank) E131881Converter A941-UL Switching DPS-200PB-172 XX (where X can be 0-9, A-Z or blank for E131881Power Supply marketing purpose and no impact safety related critical A942-UL components and constructions.) Switching FP-250-8 E131881Power Supply A943-UL Switching D350E-S0, D350E-S2 E131881Power Supply A944-UL Switching DPS-400AB-5 XX, RPS-400X1X2 XX (where X, X1, X2 can be E131881Power Supply any alphanumeric, blank or dash) A946-UL Switching DPS-650SB XX (Where X can be any alphanumeric or blank) E131881Power Supply A947-UL Switching DPS-270CB XX (where X can be any alphanumeric or blank.) E131881Power Supply A949-UL Switching N250E-S0 E131881Power Supply A950-UL DC-DC DNK12S0A0R30NXX (where X can be any alphanumeric E131881Converter character or blank) A951-UL Switching CP-1000 Power Supply DC-DC D48Q130 A Converter Switching N255ED-00 Power Supply Switching DPS-320JB XX (where X can be any alphanumeric character Power Supply or blank) Switching D750P-S0 Power Supply Switching FP-150-7, FP-150-8 Power Supply Switching DPS-320KB-1 XX (where X can be any alphanumeric Power Supply character or blank) Switching DPS-240RB XX (Where X can be 0-9, A-Z or blank) Power Supply Switching DPS-240QB XX (X = 0-9, A-Z or blank) Power Supply Switching EDPS-250AF XX and EDPS-250BF XX (where X can be any Power Supply alphanumeric character or blank) Switching DPS-200PB-171 XX (where X can be any alphanumeric Power Supply character or blank) Switching GPS-430AB XX (X can be 0-9, A-Z or blank) Power Supply Switching (1) CAA-550AT XX, CAA-550CT XX, CAA-500AT XX, CAAPower Supply 500BT XX (X = 0-9, A-Z or blank); E131881A952-UL E131881A954-UL E131881A955-UL E131881A956-UL E131881A958-UL E131881A959-UL E131881A960-UL E131881A963-UL E131881A964-UL E131881A965-UL E131881A967-UL E131881A970-UL E131881A972-UL

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 22

Date: 2012-07-03

(2) GPS-550AG, GPS-550A, GPS-500AG, GPS-500A; (3) CAA-450AT XX,CAA-450BT XX,CAA-400AT XX,CAA400BT XX; (4) GPS-450A,GPS-450AG,GPS-400A,GPS-400AG. DC-DC AC-089 XX (X can be any alphanumeric or blank) Converter Switching DPS-850FB XX (where X can be A-Z, 0-9 or blank) Power Supply Switching DPS-350YB XX ( where X can be any alphanumeric or blank.) Power Supply Switching D235PS-00 Power Supply Switching DPS-430EB XX, (where "X" can be any alphanumeric or Power Supply blank.) AC-084 XX, (where "X" can be any alphanumeric or blank.) Switching D280ES-00 Power Supply Switching D235ES-00 Power Supply Switching GPS-500BB XX (X can be 0-9, A-Z or Blank) Power Supply DC-DC Q48SA52001XXXX , H48SA48003XXXX and Converter Q48SA54001XXXX. (X can be any alphanumeric or blank) Switching D255ED-00 Power Supply Switching EDPS-501AF AX, EDPS-501AF BX, and EDPS-501AF CX Power Supply (where X can be alphanumeric character or blank.) Switching D300ED-00 Power Supply Switching EDPS-220AB XX (X = 0-9, A-Z, or blank.) Power Supply Switching EDPS-165AF XX, EDPS-165BF XX (where X can be Power Supply alphanumeric character or blank.) Switching DPS-300AB-49 XX (X=0-9, A-Z or blank) Power Supply Switching DPS-750QB XX, AC-081 XX (where X can be any Power Supply alphanumeric character or blank) Power Supply CE366X01R0, DPL-150AB X (where X can be any alphanumeric characters or blank) Switching EDPS-135AF XX, EDPS-135AB BX (X can be any Power Supply alphanumeric or blank) Switching BP550 PLUS Power Supply Switching EADP-130CF XX (X=0-9, A-Z or blank) Power Supply DC-DC D48D42-2 XX (where X can be any alphanumeric or blank) Converter DC-DC Q48SCX1X2XXXX (X1=3R3, X2=25; X1=1R5, X2=40; Converter X1=1R2, X2=25; X1=120, X2=08; X=0-9, A-Z, or blank) Switching DPS-770CB XX and DPS-650RB XX (Where X can be any Power Supply alphanumeric character or blank) DC-DC EDPS-645BB XX (where X = can be any alphanumeric or

E131881A975-UL E131881A979-UL E131881A982-UL E131881A984-UL E131881A985-UL E131881A987-UL E131881A989-UL E131881A990-UL E131881A991-UL E131881A993-UL E131881A994-UL E131881A996-UL E131881A997-UL E131881A1003-UL E131881A1006-UL E131881A1008-UL E131881A1014-UL E131881A1015-UL E131881A1016-UL E131881A1017-UL E131881A1018-UL E131881A1019-UL E131881A1021-UL E131881-

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 23

Date: 2012-07-03

Converter blank) A1022-UL Switching DPS-400AB-8 XX (Where X can be any alphanumeric E131881Power Supply character or blank.) A1023-UL Switching DPS-350AB-12 XX E131881Power Supply A1024-UL Switching ADP-130BF B, DPS-130MB XX (where X can be any E131881Power Supply alphanumeric or blank) A1025-UL Switching DPL-120AB AAX, DPL-120AB ADX, DPL-120AB AEX, DPL- E131881Power Supply 120AB AFX, DPL-120AB AGX, DPL-120AB AHX, DPL-120AB A1026-UL AIX, DPL-120AB AJX, DPL-120AB DXX, DPL-120AB JX, DPL120CB XX, DPL-100CB XX (where X can be any alphanumeric characters or blank) DPL-120AB AXX (where X can be any alphanumeric characters or blank, and the first "X" exclude A, D, E, F, G, H, I, J) Switching DPS-750UB XX, RMN: HSTNS-PD22, DPS-750UB BX, RMN: E131881Power Supply HSTNS-PD22B, DPS-460FB XX, RMN: HSTNS-PD23, DPS- A1028-UL 460FB BX, RMN: HSTNS-PD23B (Where X can be 0-9, A-Z or blank) Switching DPS-350AB-14 XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1029-UL Switching DPS-218CB XX (where X can be any alphanumeric or blank) E131881Power Supply A1030-UL Switching DPS-1200FB-1 XX, RMN: HSTNS-PD19, DPS-1200FB-1 BX, E131881Power Supply RMM: HSTNS-PD21 (Where X can be 0-9, A-Z or blank) A1031-UL Power Supply EADP-200DB E131881A1032-UL Switching DPS-2980AB XX (X = 0-9, A-Z, or blank.) E131881Power Supply A1034-UL DC-DC H48SA28016XXXX (X=0-9, A-Z, or blank) E131881Converter A1037-UL Switching DPS-750WB XX(where X can be any alphanumeric character E131881Power Supply or blank) A1046-UL Switching DPS-2450AB XX (X = 0-9, A-Z, or blank.), RMN:HSTNS-PD16 E131881Power Supply A1048-UL DC-DC V48SHX1X2XXXX (X1=050, X2=20 or 17; X1=1R8, X2=40 or E131881Converter 30; X1=3R3, X2=30 or 25; X=0-9, A-Z or blank) A1050-UL Switching (1) TDPS-550CB XX (The first X can be A, C-Z, 0-9 or blank, E131881Power Supply second X can be A-Z, 0-9 or blank.); A1052-UL (2) TDPS-550CB BX (The X can be A-Z, 0-9 or blank.). (3) TDPS-550CB-1 XX (The X can be A-Z, 0-9 or blank.). Switching TDPS-138AF XX and TDPS-138AF BX (where X can be any Power Supply alphanumeric or blank for marketing purpose and no impact safety related critical components and constructions) Switching EDPS-350CB XX (Where X = 0-9, A-Z or blank) Power Supply Switching DPS-220AB-3 XX (where X can be 0-9, A-Z or blank) Power Supply Switching DPS-250AB-55 XX (X=0-9, A-Z or blank) Power Supply Switching EDPS-715AB XX (Where X can be any alphanumeric or blank) Power Supply

E131881A1054-UL E131881A1056-UL E131881A1058-UL E131881A1061-UL E131881A1062-UL

File E131881 Index

Volume X7

Page 24

Date: 2012-07-03

DC-DC EDPS-220BB XX (where X can be any alphanumeric or blank) E131881Converter A1063-UL Switching DPS-300AB-54 XX (X = 0-9, A-Z, or blank.) E131881Power Supply A1067-UL Switching DPL-180AB XX (where X can be any alphanumeric characters E131881Power Supply or blank) A1068-UL Switching DPS-550JB XX (where X can be any alphanumeric or blank) E131881Power Supply A1072-UL Switching DPS-250AB-54 XX (Where X can be any alphanumeric or E131881Power Supply blank for marketing purpose and no impact safety related A1073-UL critical components and constructions.) Switching DPS-150QB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1076-UL Switching EDPS-915AF XX (X = 0-9, A-Z or blank) E131881Power Supply A1077-UL Switching DPS-460GP XX, DPS-460HP XX (where X can be 0-9, A-Z, or E131881Power Supply blank.) A1078-UL Switching DPS-750VB XX (X = 0-9, A-Z or blank) E131881Power Supply A1081-UL Switching DPS-250AB-60 XX E131881Power Supply A1083-UL Switching CE366X02 E131881Power Supply A1084-UL Switching DPS-475CB-2 XX (Where X can be any alphanumeric or E131881Power Supply blank) A1085-UL Switching EDPS-133AB B, EDPS-133AB C E131881Power Supply A1086-UL Switching EDPS-69AB AX (X = any alphanumeric except for A and C, or E131881Power Supply blank) A1087-UL Switching EDPS-69AB CX (X can be any alphanumeric character except E131881Power Supply for A and C, or blank) A1088-UL Switching DPL-150BB XX (X = 0-9, A-Z, "-", or blank.) E131881Power Supply A1089-UL DC-DC (1) Q48SK12033XXXX, Q48SK12018XXXX (X=0-9, A-Z or E131881Converter blank for marketing purpose and no impact safety related A1090-UL critical components and constructions); (2) Q48SK12025XXXX (X=0-9, A-Z or blank except NNFO for marketing purpose and no impact safety related critical components and constructions); (3) Q48SK12025NNFO Switching DPS-60QB XX (Where X can be any alphanumeric or blank) E131881Power Supply A1092-UL Switching ADP-85AF S, ADP-85AF U E131881Power Supply A1094-UL Switching DPS-500VB XX (X = 0-9, A-Z or blank) E131881Power Supply A1096-UL for building-in Switching CE366X03 E131881Power Supply A1098-UL Switching DPS-1755AB XX (Where X can be any alphanumeric or blank) E131881Power Supply A1099-UL Switching HCP-1200 E131881Power Supply A1100-UL Switching GPS-400CB XX, DPS-400AB-16 XX (where X can be 0-9, A-Z E131881Power Supply or blank) A1104-UL

Withdrawn

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 25

Date: 2012-07-03 E131881A1107-UL E131881A1108-UL E131881A1110-UL E131881A1114-UL E131881A1115-UL E131881A1116-UL E131881A1118-UL E131881A1119-UL E131881A1120-UL E131881A1121-UL E131881A1122-UL E131881A1123-UL E131881A1124-UL E131881A1125-UL E131881A1126-UL E131881A1127-UL E131881A1128-UL E131881A1130-UL E131881A1131-UL E131881A1132-UL E131881A1133-UL E131881A1135-UL E131881A1137-UL E131881A1142-UL Withdrawn

Switching DPS-180AB-6 XX (X = 0-9, A-Z, or blank.) Power Supply Switching HCG-900, EA-900 GREEN, HCG-750, HCG-750 RED, HCGPower Supply 750 OC, EA-750 GREEN DC-DC E48SPX1X2XXXX (X1=120, X2=20; or X1=3R3, X2=40 or 60; Converter X=0-9, A-Z or blank, "for marketing purpose and no impact safety related critical components and constructions) Switching DPS-400AB-10 XX (where X can be A-Z, 0-9 or blank) Power Supply Switching DPS-410DB XX (X can be 0-9, A-Z or blank for marketing Power Supply purpose and no impact safety related critical components and constructions.) Switching DPS-300AB-57 XX (where X can be 0-9, A-Z or blank) Power Supply Switching DPS-380CP-2 XX ( where X can be any alphanumeric or blank Power Supply for marketing purpose and no impact safety related critical components and constructions) Switching HCP-850 Power Supply Switching EDPS-240AB XX where X can be 0-9, A-Z, or blank Power Supply Switching LE011X01R0 Power Supply Switching Model: N650P-00 Power Supply for building-in Power supply NPS-420AB X where X can be 0-9, A-Z except D or blank or NPS-420AB D Power Supply NPS-700AB X, where X can be any alphanumeric character or for building-in blank Power Supply NPS-210BB X (X= 0 - 9, A - Z or Blank) for building-in Building-in NPS-360BB X where X may be 0-9, A-Z or blank. power supply Switching N750P-00 Power Supply for building-in Power Supply N1000E-00 Switching DPS-250AB-59 XX (where X can be 0-9, A-Z or blank for Power Supply marketing purpose and no impact safety related critical components and constructions.) Switching EDPS-150AF XX (X=0-9, A-Z, or blank) Power Supply Switching LE011X02R0 Power Supply Switching EDPS-600ABXX(where X can be any alphanumeric or blank) Power Supply Switching DPS-300AB-56 XX (Where X can be any alphanumeric or Power Supply blank) Switching DPS-650UB XX (where X can be 0-9, A-Z or blank) Power Supply Switching DPS-120TB XX (Where X can be any alphanumeric or blank Power Supply for marketing purpose and no impact safety related critical components and constructions.)

Withdrawn

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 26

Date: 2012-07-03 Withdrawn

Switching LE028X01 E131881Power Supply A1143-UL Switching NPS-400CB XX (X=0-9, A-Z or blank) E131881Power Supply A1144-UL Switching DPL-160AB XX, DPL-160BB XX, DPL-200BB XX (X = 0-9, E131881Power Supply A-Z, "-", or blank.) A1145-UL Power Supply EDPS-250AB XX (where X can be any alphanumeric or blank E131881Unit for marketing purpose and no impact safety related critical A1147-UL components and constructions) Switching DPS-250AB-62 XX (Where X can be 0-9, A-Z or blank) E131881Power Supply A1149-UL Switching D250ED-00 E131881Power Supply A1151-UL Switching D250AD-00 E131881Power Supply A1152-UL Switching DPS-500YB XX (X = 0-9, A-Z, or blank.) E131881Power Supply A1154-UL Power Supply EDPS-350DB XX (X=0-9, A-Z or blank) E131881Unit A1155-UL Switching EDPS-300AB XX (Where X can be any 0-9, A-Z, dash or E131881Power Supply blank) A1158-UL Switching DPS-500XB XX (The first X is letter X , the last two X can be E131881Power Supply any alphanumeric or blank.) A1159-UL for building-in Switching DPS-320NB-1 XX (where X can be any alphanumeric E131881Power Supply character or blank for marketing purpose and no impact safety A1161-UL related critical components and constructions.) Switching DPS-1300CB XX (where X can be 0-9, A-Z, dash or blank) E131881Power Supply A1162-UL Switching EA-650 GREEN, BP550 E131881Power Supply A1164-UL Switching DPS-240TB XX (Where X can be 0-9, A-Z, or blank for E131881Power Supply marketing purpose and no impact safety related critical A1168-UL components and constructions.) Switching D1200E-S0, D1200E-S1 E131881Power Supply A1171-UL Switching DPS-400AB-13 XX (X=0-9, A-Z or blank) E131881Power Supply A1172-UL Switching DPS-700NB XX (X can be A-Z, 0-9 or blank, for marketing E131881Power Supply purpose only) A1173-UL Switching DPS-320NB XX (X= 0-9, A-Z or Blank) E131881Power Supply A1174-UL Switching DPS-220UB-5 XX, DPS-235JB XX (where X can be any E131881Power Supply alphanumeric or blank) A1175-UL Switching DPS-300AB-62 XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1181-UL Switching DPS-460LB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1183-UL Switching DPS-450TB XX (where X can be any alphanumeric or blank for E131881Power Supply marketing purpose and no impact safety related critical A1185-UL components and constructions.) Switching DPS-400AB-12 XX (X can be any alphanumeric or blank) E131881Power Supply A1186-UL Switching DPS-120UB XX (Where X can be any alphanumeric or blank.) E131881Power Supply A1188-UL

Withdrawn

File E131881 Index

Volume X7

Page 27

Date: 2012-07-03 E131881A1191-UL E131881A1192-UL E131881A1193-UL

Switching EDPS-300BB XX (where X can be any alphanumeric or blank) Power Supply DC-DC V48SC12007XXXX, V48SC12008XXXX (where X can be any Converter alphanumeric or blank) Switching DPS-250AB-72 XX (where X can be any alphanumeric or Power Supply blank)

Switching DPSN-600AB XX (Where first X=0-9, A-Z or blank except B, C E131881Power Supply and D, second X=0-9, A-Z or blank), A1194-UL DPSN-600AB BX (Where X=0-9, A-Z or blank), DPSN-600AB CX, DPSN-600AB DX, DPSN-600AB-1 XX (Where X=0-9, A-Z or blank) DPS-400AB-14 XX (X can be 0-9, A-Z or blank)

Switching E131881Power Supply A1195-UL Switching DPS-236BB XX (where X can be any alphanumeric or blank for E131881Power Supply marketing purpose and no impact safety related critical A1196-UL components and constructions.) Switching EDPS-180AF XX (where X might be any alphanumeric E131881Power Supply character or blank) A1197-UL Switching DPS-460DB-5 XX (Where X can be any alphanumeric or E131881Power Supply blank) A1198-UL DC-DC E36SR12004XXXX, E36SR12005XXXX(X=0-9, A-Z or blank, E131881Converter for marketing purpose and no impact safety related critical A1199-UL components and constructions) Switching EADP-200BF XX (Where X can be any alphanumeric or blank, E131881Power Supply for marketing purpose and no impact safety related critical A1200-UL components and constructions.) Switching (1) DPS-460JB XX (HSTNS-PD26), E131881Power Supply (2) DPS-500AB-2 XX (HSTNS-PD24) A1201-UL (Where X can be any alphanumeric or blank.) Switching DPS-800PB XX (X can be 0-9, A-Z or blank.) E131881Power Supply A1202-UL Switching DPS-250AB-71 XX (where X can be 0-9, A-Z or blank, first X E131881Power Supply can not be B), DPS-250AB-71 BX (where X can be 0-9, A-Z or A1203-UL blank). Switching DPS-600WB XX, GPS-650FB XX, GPS-550GB XX, GPSE131881Power Supply 500EB XX (X can be 0-9, A-Z or blank.) A1204-UL Switching D1080E-S0 E131881Power Supply A1205-UL Switching VP350 E131881power supply A1208-UL Switching DPS-300AB-61 xx (x = 0-9, A-Z or blank) E131881Power Supply A1209-UL (built-in type) Switching EDPS-1000AB XX (where X can be any alphanumeric E131881Power Supply character or blank); A1210-UL DPS-1000LB XX (where X can be any alphanumeric character or blank) Switching DPS-220AB-6 XX (where X can be any alphanumeric or blank) E131881Power Supply A1211-UL Switching EDPS-585AB XX (Where X can be any alphanumeric E131881Power Supply characters or blank.) A1213-UL

Withdrawn

File E131881 Index

Volume X7

Page 28

Date: 2012-07-03

Switching DPS-800NB XX, DPS-450SB XX, DPS-800QB XX, DPSE131881Power Supply 750XB XX, DPS-450UB XX, DPS-800RB XX, DPS-800UB XX, A1217-UL DPS-450SB-1 XX (Where X can be any alphanumeric or blank.) Power Supply EADP-185AB E131881A1218-UL SWITCHING D250PD-00, D250ND-00 E131881POWER A1223-UL SUPPLY SWITCHING D300PD-00, D300ND-00, D300PM-00 E131881POWER A1224-UL SUPPLY SWITCHING EDPS-215AB XX (where X can be any alphanumeric or blank) E131881POWER A1225-UL SUPPLY Switching D1080N-S0 E131881Power Supply A1226-UL Switching EDPS-1560AB XX (X can be 0-9, A-Z or blank.) E131881Power Supply A1227-UL SWITCHING DPS-600VB xx (x can be 0-9, A-Z or blank) E131881POWER A1234-UL SUPPLY Switching DPS-250AB-75 XX (Where X can be any alphanumeric or E131881Power Supply blank for marketing purpose and no impact safety related A1237-UL critical components and constructions.) Switching DPS-250AB-70 XX (X can be 0-9, A-Z or blank.) E131881Power Supply A1238-UL Switching DPS-280QB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1243-UL Switching EDPS-620AB XX (Where X can be any alphanumeric E131881Power Supply characters or blank.) A1248-UL Switching DPS-75VB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1257-UL Switching D425EF-00 E131881Power Supply A1261-UL Switching D635EF-00 E131881Power Supply A1267-UL Switching DPS-2500CB XX (where X can be 0-9, A-Z or blank) E131881Power Supply A1268-UL Switching D825EF-00 E131881Power Supply A1269-UL Switching DPS-1125AB XX (where X can be any alphanumeric or blank) E131881Power Supply A1272-UL Switching DPS-600UB XX (where X can be any alphanumeric or blank; E131881Power Supply for marketing purpose and no impact safety related critical A1274-UL components and constructions) Switching DPS-850GB XX (where X can be any alphanumeric or blank) E131881Power Supply A1275-UL Switching DPS-750AB-1 XX ( where X can be 0-9, A-Z or blank) E131881Power Supply A1277-UL DC-DC E48SC12008XXXX, E48SC12005XXXX (Where X=0-9, A-Z, or E131881Converter blank) A1279-UL Switching DPS-550LB XX, DPS-460KB XX (where X can be 0-9, A-Z or E131881Power Supply blank) A1281-UL Switching ADP-6CF S E131881-

File E131881 Index

Volume X7

Page 29

Date: 2012-07-03

Power Supply Switching D240ES-00 Power Supply Switching D265EM-00 Power Supply Switching ADP-200DB B Power Supply Switching PWS-1K25P-PQ, DPS-1200QB XX (where X can be 0-9, A-Z Power Supply or blank) Switching D495E-S0, D750E-S1 Power Supply Switching 1. DPS-460MB XX, RMN:HSTNS-PD28. Power Supply 2. DPS-750AB-3 XX, RMN:HSTNS-PD29. Switching DPS-400AB-15 XX (where X can be any alphanumeric or Power Supply blank) Switching EA-432 GREEN Power Supply Power Supply EDPS-300EB xx (x = 0-9, A-Z or blank)

A1282-UL E131881A1284-UL E131881A1286-UL E131881A1289-UL E131881A1291-UL E131881A1293-UL E131881A1298-UL E131881A1299-UL E131881A1300-UL E131881A1301-UL DC-DC V48SH1R050XXXX,V48SH1R235XXXX,V48SH1R035XXXX E131881Converter (where X can be any alphanumeric or blank) A1302-UL Switching D1300EF-00 E131881Power Supply A1308-UL Switching HAC-60AP XX (where X can be any alphanumeric or blank for E131881Power Supply marketing purpose and no impact safety related critical A1309-UL components and constructions.) Switching GPS-450AB XX, GPS-400DB XX (where X can be any E131881Power Supply alphanumeric or blank) A1311-UL SWITCHING EA-350 GREEN E131881POWER A1317-UL SUPPLY Switching DPS-1200SB XX, RMN: HSTNS-PD30 ( where X can be any E131881Power Supply alphanumeric or blank) A1318-UL Switching DPS-1120AB XX (Where XX can be any alphanumeric or E131881Power Supply blank.) A1322-UL Switching DPS-100AB-5 XX (where X can be any alphanumeric or blank E131881Power Supply for marketing purpose and no impact safety related critical A1330-UL components and constructions.) SWITCHING DPS-750AB-4 XX, RMN: HSTNS-PD31 E131881POWER (Where X can be any alphanumeric or blank) A1334-UL SUPPLY DPS-750AB-8 XX, RMN: HSTNS-PD32 (Where X can be 0-9, A-Z or blank) DC-DC Q36SR12017XXXX, Q36SR12019XXXX (where X can be any E131881Converter alphanumeric or blank. For marketing purpose and no impact A1336-UL safety related critical components and constructions.) Switching D1200E-S0, D1200E-S1, D1200E-S2, D1200E-S3 E131881Power Supply A1338-UL Switching 1) DPS-1200TB XX; E131881Power Supply 2) DPS-1200RB XX; A1340-UL (where X can be any alphanumeric or blank) Switching DH550E-S0 E131881Power Supply A1341-UL Switching DPS-500AB-3 XX, HSTNS-PD27 (Where X can be any E131881Power Supply alphanumeric or blank.) A1349-UL

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 30

Date: 2012-07-03 E131881A1351-UL E131881A1352-UL E131881A1354-UL E131881A1355-UL E131881A1357-UL E131881A1358-UL E131881A1359-UL E131881A1360-UL E131881A1362-UL E131881A1364-UL E131881A1365-UL E131881A1372-UL E131881A1373-UL E131881A1377-UL E131881A1378-UL E131881A1379-UL E131881A1383-UL E131881A1384-UL E131881A1388-UL E131881A1390-UL E131881A1393-UL E131881A1395-UL E131881A1396-UL E131881A1397-UL E131881A1399-UL E131881A1405-UL

Switching DPS-180AB-9 XX (where X can be any alphanumeric or blank) Power Supply Switching DH550E-S1 Power Supply Switching DPS-300AB-73 XX (Where X=0-9, A-Z or blank) Power Supply Switching DPS-1400BB XX (where X can be 0-9, A-Z or blank) Power Supply Switching EDPS-172CB xx (x can be 0-9, A-Z or blank) Power Supply (Built-in type) Switching DPS-300AB-72 XX (Where X=0-9, A-Z or blank) Power Supply Switching DH350E-S0 Power Supply Switching D240ES-01 Power Supply Switching D320EM-00, D275EM-00 Power Supply Switching DPS-350AB-20 XX (where X=0-9, A-Z or blank) Power Supply Switching D240AS-00 Power Supply Switching D250ED-01 Power Supply Switching D550E-S0 Power Supply Switching D350E-S1 Power Supply Switching DPS-600AB-2 XX (where X=0-9, A-Z or blank) Power Supply Switching D250AD-01 Power Supply Switching DPS-231CB XX, DPS-300AB-76 XX (X=0-9, A-Z or blank) Power Supply Switching DPS-250AB-77 XX (Where X can be 0-9, A-Z or blank) power supply DC-DC Q48SK11049XXXX (X=0-9, A-Z or blank and for marketing Converter purpose only, and no impact safety related constructions and critical components.) DC-DC EDPS-1BF A Converter Switching D460AM-01 Power Supply Switching DPS-500WB XX (X=0-9, A-Z or blank) Power Supply Switching DPS-700PB XX (X=0-9, A-Z or blank) Power Supply Switching HCP-650 Gold, HCP-550 Gold Power Supply SWITCHING EDPS-92BB A, EDPS-92BB C POWER SUPPLY Switching D220AS-00, D220ES-00 Power Supply

Withdrawn

File E131881 Index

Volume X7

Page 31

Date: 2012-07-03

Switching D220PS-00 E131881Power Supply A1407-UL Switching HCP-1000 Platinum E131881Power Supply A1408-UL Switching D200EU-00 E131881Power Supply A1411-UL SWITCHING EDPS-69BB A, EDPS-69BB C E131881POWER A1414-UL SUPPLY Switching DPS-600AB-1 XX(where X can be any alphanumeric or blank ) E131881Power Supply A1415-UL Switching EDPS-291AB xx (Where x can be 0-9, A-Z or blank.) E131881Power Supply A1417-UL Switching D235EU-00 E131881Power Supply A1418-UL Switching VP550F, VP550P V2 E131881Power Supply A1422-UL Switching DPS-250AB-82 XX (X=0-9, A-Z or blank) E131881Power Supply A1425-UL SWITCHING EDPS-172BB AA E131881POWER A1427-UL SUPPLY Switching DPS-250AB-84 XX (where X can be any alphanumeric E131881Power Supply character or blank) A1428-UL Switching DPS-300AB-77 XX, GPS-300GB XX (where X=0-9, A-Z or E131881Power Supply blank) A1432-UL SWITCHING EDPS-172AB AA E131881POWER A1433-UL SUPPLY Telecom DPST-900AL XX (X=0-9, A-Z or blank) E131881Power Supply A1438-UL Telecom DPST-1000DB XX (X=0-9, A-Z or blank) E131881Power Supply A1439-UL Telecom DPST-1000EB XX (X=0-9, A-Z or blank) E131881Power Supply A1440-UL RackDPST-1225AB XX and DPST-1150AB XX (X can be any E131881Mounted alphanumeric character or blank) A1441-UL Switching Power Supply Telecom DPST-1200AB X (where X could be any alphanumeric or E131881Power Supply blank) A1442-UL (SMR) Telecom DPST-2100AB XX (X=0-9, A-Z or blank) E131881Power Supply A1443-UL Telecom DPST-2500CB XX (X=0-9, A-Z or blank) E131881Power Supply A1444-UL Telecom DPST-3000BB XX (X=0-9, A-Z or blank) E131881Power Supply A1445-UL Telecom DPST-6000AB X, where X may be any alphanumeric character E131881Power Supply or blank A1446-UL (SMR) Switching DPS-250AB-83 XX(X can be 0-9, A-Z or blank, for marketing E131881Power Supply purpose only and no impact safety related critical components A1447-UL and constructions) Telecom DPST-6000BB X, where X may be any alphanumeric character E131881-

Withdrawn

Withdrawn

File E131881 Index

Volume X7

Page 32

Date: 2012-07-03

Power Supply or blank A1448-UL (SMR) Switching DPS-500AB-4 XX (X=1-9, A-Z or blank) E131881Power Supply A1450-UL Switching ADP-160AR E131881Power Supply A1452-UL SWITCHING DPS-450AB-1 XX (Where X=0-9, A-Z or blank) E131881POWER A1454-UL SUPPLY Switching DPS-800TB XX, DPS-750AB-5 XX (X can be 0-9, A-Z or blank E131881Power Supply for marketing purpose and no impact safety related critical A1455-UL components and constructions) Switching DPS-800SB XX (X can be 0-9, A-Z or blank, for marking E131881Power Supply purpose only, and not safety related) A1457-UL Switching D300EM-00 E131881Power Supply A1462-UL Switching DPS-96GP xx (Where X can be any alphanumeric or blank) E131881Power Supply A1464-UL Switching ADP-185BF T E131881Power Supply A1465-UL Switching DPS-100AP-6 xx E131881Power Supply ( where x can be any alphanumeric or blank A1467-UL "for marketing purpose and no impact safety related critical components and constructions ) Switching DPS-180AB-8 XX, DPS-230QB XX (Where X can be any E131881Power Supply alphanumeric or blank) A1468-UL DC-DC G48SK12050XXXX (where X can be any alphanumeric or E131881Converter blank, for marketing purpose and no impact safety related A1471-UL critical components and constructions.) Switching DPS-425BL Ax E131881Power Supply ( where x can be any alphanumeric or blank A1475-UL "for marketing purpose and no impact safety related critical components and constructions ) Switching DPS-250AB-81 XX (X can be 0-9, A-Z or blank); AC-110 A; E131881Power Supply RPS-500-18 XX (X can be 0-9, A-Z or blank) A1476-UL Switching NPS-173AB XX (X=A-Z, 0-9 or blank) E131881Power Supply A1477-UL Telecom DPST-5000AB XX (X=0-9, A-Z or blank) E131881Power Supply A1478-UL Switching DPS-550QB XX(RMN:RSVLC-1201B) (X can be 0-9, A-Z or E131881Power Supply blank) A1481-UL DC-DC D48S750XXXX (where X can be any alphanumeric or blank, E131881Converter for marketing purpose and no impact safety related critical A1484-UL components and constructions.) SWITCHING PMT-24V50W1AA, PMT-24V35W1AA, PML-24V50W1AA, E131881POWER PML-24V35W1AA, PMB-24V50W1AA, PMB-24V35W1AA, A1485-UL SUPPLY PMT-24V50W1AH, PMT-24V35W1AH, PML-24V50W1AH, PML-24V35W1AH, PMB-24V50W1AH, PMB-24V35W1AH Switching DPS-260MB XX (X=A-Z, 0-9 or blank) E131881Power Supply A1486-UL SWITCHING DPS-450AB-2 XX (Where X can be any alphanumeric or blank) E131881POWER A1487-UL SUPPLY Switching ADP-300AF T E131881Power Supply A1488-UL

File E131881 Index

Volume X7

Page 33

Date: 2012-07-03 E131881A1492-UL E131881A1499-UL

Switching TDPS-150BB XX, where XX represents any alphanumeric Power Supply character or blank DC-DC E36SC12009XXXX (Where X can be any alphanumeric or Converter blank for marketing purpose and no impact safety related critical components and constructions)

Issue Date:

2012-05-18 2012-07-05

Page 1 of 19

Report Reference #

E131881-A1485-UL

UL TEST REPORT AND PROCEDURE


Standard: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) SWITCHING POWER SUPPLY PMT-24V50W1AA, PMT-24V35W1AA, PML-24V50W1AA, PML24V35W1AA, PMB-24V50W1AA, PMB-24V35W1AA, PMT24V50W1AH, PMT-24V35W1AH, PML-24V50W1AH, PML24V35W1AH, PMB-24V50W1AH, PMB-24V35W1AH, PMT-12V50W1AA, PMT-12V50W1AH, PMB-12V50W1AA, PMB12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PML12V50W1AA, PML-12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH, PMB-12V35W1AA, PMB12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, PML12V35W1AA, PML-12V35W1AH. AC Input: 100-240Vac, 1.5A, 50-60Hz, DC Output: Model: PMT-24V50W1AA, PML-24V50W1AA, PMB-24V50W1AA, PMT-24V50W1AH, PML-24V50W1AH, PMB-24V50W1AH. Output: 24Vdc, 2.1A. Model: PMT-24V35W1AA, PML-24V35W1AA, PMB-24V35W1AA, PMT-24V35W1AH, PML-24V35W1AH, PMB-24V35W1AH. Output: 24Vdc, 1.46A. Model: PMT-12V50W1AA, PMT-12V50W1AH, PMB-12V50W1AA, PMB-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PML12V50W1AA, PML-12V50W1AH. Output: 12Vdc, 4.2A. Model: PMT-12V35W1AA, PMT-12V35W1AH, PMB-12V35W1AA, PMB-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, PML12V35W1AA, PML-12V35W1AH. Output: 12Vdc, 2.92A. Applicant Name and Address: DELTA ELECTRONICS INC 3 TUNGYUAN RD CHUNGLI INDUSTRIAL ZONE TAOYUAN COUNTY 32063 TAIWAN

Certification Type: CCN: Product: Model:

Rating:

Copyright 2012

Issue Date:

2012-05-18 2012-07-05

Page 2 of 19

Report Reference #

E131881-A1485-UL

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability.

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.

Prepared by:

Amos Chen

Reviewed by: Nate Hsu

Copyright 2012

Issue Date:

2012-05-18 2012-07-05

Page 3 of 19

Report Reference #

E131881-A1485-UL

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description Electronic components mounted on PWB and housed in metal chassis. Model Differences See Enclosure 7-07 and 7-08 for model difference. The attachment in Enclosure 7-07 and 7-08 are different in the following components: C1, J6, J8, J9, D101, C102, C105, R131, R133, R135, R136, VR131, ZD131, R11, R34, C33, R38, R43, HS1, HS2, CN1, metal cover, and metal chassis. See appended table 1.5.1 for further information. Technical Considerations Equipment mobility : for building-in Connection to the mains : determin in end product Operating condition : continuous Access location : operator accessible Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : +10%, -10% Tested for IT power systems : No IT testing, phase-phase voltage (V) : N/A Class of equipment : Class I (earthed)

Issue Date:

2012-05-18 2012-07-05

Page 4 of 19

Report Reference #

E131881-A1485-UL

Considered current rating of protective device as part of the building installation (A) : 20 Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : up to 3048 Altitude of test laboratory (m) : Less than 2000 Mass of equipment (kg) : 0.23(Models PMT-24V50W1AA, PMT-24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH); 0.175(Models PML-24V50W1AA, PML-24V35W1AA, PML-24V50W1AH, PML24V35W1AH); 0.12(Models PMB-24V50W1AA, PMB-24V35W1AA, PMB-24V50W1AH, PMB24V35W1AH) The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturers specification of: 50 degree C The product is intended for use on the following power systems: TN The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 (which includes all European national differences, including those specified in this test report)., The equipment is operated up to 3,048 m (10,000 feet) above sea level as declared by manufacturer. Clearance have been evaluated according to IEC 60664-1 table A.2 with a multiplication factor of 1.15 throughout this report (3000m : 1.14, 4000m : 1.29, linear interpolation between this value was considered) The following accessible locations (with circuit/schematic designation) are within a limited current circuit: CY5 secondary The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual All test were performed with F1, by Bel fuse limited, Type 5HT AC rated 250V, T3.15AH under this investigation.

Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength, Earthing Continuity The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-

Issue Date:

2012-05-18 2012-07-05

Page 5 of 19

Report Reference #

E131881-A1485-UL

SELV: 327 Vrms, 592 Vpk, Primary-Earthed Dead Metal: 327 Vrms, 592 Vpk The following secondary output circuits are SELV: All Secondary output The following secondary output circuits are at non-hazardous energy levels: +24V The following output terminals were referenced to earth during performance testing: Secondary GND The power supply terminals and/or connectors are: Suitable for factory wiring only The maximum investigated branch circuit rating is: 20 A The investigated Pollution Degree is: 2 Proper bonding to the end-product main protective earthing termination is: Required An investigation of the protective bonding terminals has: Not been conducted The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105C): T1 (Class B) The following end-product enclosures are required: Electrical, Fire, Mechanical

Additional Information N/A Additional Standards The product fulfills the requirements of: EN 60950-1:2006 + A11:2009 + A1:2010 + A12: 2011. Markings and instructions Clause Title Power rating - Ratings Ratings (voltage, frequency/dc, current) Marking or Instruction Details

Power rating Model

Model Number

Power rating Company identification Fuses - Rating

Listee's or Recognized company's name, Trade Name, Trademark or File Number

Issue Date:

2012-05-18 2012-07-05

Page 6 of 19

Report Reference #

E131881-A1485-UL

Rated current and voltage and type located on or adjacent to fuse or fuseholder. Special Instructions to UL Representative Production-Line Electric Strength (Dielectric Voltage-Withstand) Test: Inspect the transformer(s) listed in Production-Line Testing Requirements (Electric Strength Test Special Constructions) per AA1.1- (C). When the tests are conducted at other location, inspect test record and specification sheet provided by the component manufacturer. Verify the specification sheet indicates 100% routine test specified in Production-Line Testing Requirements (Electric Strength Test Special Constructions) be conducted at the component manufacturer.

Issue Date:

2012-05-18 2012-07-05

Page 7 of 19

Report Reference #

E131881-A1485-UL

Production-Line Testing Requirements Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information. Model T1 Component N/A Removable Parts N/A Test probe location V rms V dc 2100 Test Time, s 1

Connector (L, N) pins to 150 Aeecssible dead metal 0 chassis Primary to Secondary 300 0

All Models PMB24V50W1AA , PMB24V35W1AA , PMB24V50W1AH , PMB24V35W1AH , PMB12V50W1AA , PMB12V35W1AA , PMB12V50W1AH , PMB12V35W1AH .

T1 N/A

N/A N/A

4242 2100

1 1

Connector (L, N) pins to 150 FG pin 0

Earthing Continuity Test Exemptions - This test is not required for the following models: All Models Electric Strength Test Exemptions - This test is not required for the following models: No exemptions Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test: -Sample and Test Specifics for Follow-Up Tests at UL Model N/A Component Material Test Sample(s) Test Specifics

Issue Date:

2012-05-18 2012-07-05

Page 8 of 19

Report Reference #

E131881-A1485-UL

1.5.1 Object/part or Description S01. Insulating Tubing/Sleeving

TABLE: list of critical components Manufacturer/ trademark Various type/model technical data Product Category CCN(s) UZFT2, YDPU2, YDTU2 Required Marks of Conformity UL

Pass Supplement ID

Various

S02. Glue S03. Label S03a. Label (alternate)

Various Various --

Various Various --

S04. Internal Plastic Parts S05. PWB S06. Connectors and Receptacles (secondary ELV/SELV circuits) 01. Primary connector (CN1) (for model PMT24V50W1AA, PMT24V35W1AA, PML24V50W1AA, PML24V35W1AA, PMB24V50W1AA, PMB24V35W1AA, PMT12V50W1AA, PMB12V50W1AA, PML12V50W1AA, PML12V50W1AA, PMT12V35W1AA, PMB12V35W1AA, PML12V35W1AA, PML12V35W1AA)

Various Various Various

Various Various Various

FEP, PTFE, PVC, TFE, neoprene, polyimide or marked VW-1 or FT-1; 105 degree C, 300 V Min. V-2: Min. 70 degree C. Printed as part of PWB, Hot stamping, laser etching or silk screened. V-2 minimum V-0, 130 degree C Copper alloy pins housed in bodies of plastic rated V-2 min 300Vac, 15A min., 120 degree C

QMFZ2 PGDQ2 or PDJI2 --

UL UL --

QMFZ2 ZPMV2 QMFZ2, ECBT2, RTRT2 XCFR2

UL UL UL

SWITCHLAB INC

T44-BSXX

UL

Issue Date:

2012-05-18 2012-07-05

Page 9 of 19

Report Reference #

E131881-A1485-UL

01a. Primary connector (CN1 ) (for model PMT24V50W1AH, PMT24V35W1AH, PML24V50W1AH, PML24V35W1AH, PMB24V50W1AH, PMB24V35W1AH, PMT12V50W1AH, PMB12V50W1AH, PML12V50W1AH, PML12V50W1AH, PMT12V35W1AH, PMB12V35W1AH, PML12V35W1AH, PML12V35W1AH) 02. Fuse (F1)

Japan Solderless Terminal Mfg Co Ltd

VH

10A, AC 250V, 85 degree C

ECBT2

UL

02a. Fuse (F1) (Alternate) 02b. Fuse (F1) (Alternate) 02c. Fuse (F1) (Alternate)

LITTELFUSE INC(for 215 UL) Suzhou Littelfuse OVS Ltd.(for CCC,VDE) Bel Fuse Limited 5HT CONQUER ELECTRONICS CO LTD EVER ISLAND ELECTRIC CO.,LTD.AND WALTER ELECTRIC Various KEMET ELECTRONICS ITALIA SRL (for UL), KEMET ELECTRONICS CORPORATION (for UDA

AC 250V, T3.15AH

JDYX2

UL

T3.15AH, AC 250V T3.15AH, AC 250V

JDYX2 JDYX2

UL UL

TSC

AC 250V, T3.15AH

JDYX2

UL

03. Thermistor (NTC1) 04. X-Capacitor (CX1, CX2 )

Various R.46

8 ohm, at 25 degree C CX1=0.22uF, CX2=0.033uF, 275Vac (For ENEC), 250Vac (For UL) 110 degree C, X2 type, Comply with IEC 6038414

-FOWX2

-UL

Issue Date:

2012-05-18 2012-07-05

Page 10 of 19

Report Reference #

E131881-A1485-UL

04a. X-Capacitor (CX1, CX2 ) (Alternate)

IMQ), 1.ARCOTRONICS ITALIA S.P.A (for CQC), 2.3. ARCOTRONICS Industries S.r.l (for CQC) Okaya Electric Industries Co., Ltd.

04b. X-Capacitor (CX1, CX2 ) (Alternate)

04 c. X-Capacitor (CX1, CX2 ) (Alternate)

04d. X-Capacitor (CX1, CX2 ) (Alternate)

04e. X-Capacitor (CX1, CX2 ) (Alternate)

Okaya Electric Industries Co., Ltd. (for ENEC and UL) OKAYA(HONGKON G)LTD DONG GUAN DONG KENG OKAYA FACTORY (for CQC) Hua Jung MKP Components Co., Ltd. (for UL and CQC), Hua Jung Electronics (Guangdong) Co., Ltd. (for ENEC) Europtronic (Taiwan) MPX Ind. Corp. (for ENEC, VDE and CQC) EUROPTRONIC (TAIWAN) INDUSTRIAL CORP (for UL) Europtronic (Taiwan) MPX2 Ind. Corp. (for ENEC, VDE and CQC)

RE Series(for UL), RE+(for UL), RE ++ (for UL), RESeries (for VDE) LE(-*) (for ENEC) LE+++ (for UL) LE Series (for UL),LE (for CQC)

CX1=0.22uF, CX2=0.033uF, FOWX2 250Vac (for UL), 0.01-2.2uF, 275Vac (for VDE) 100 degree C, X2 type CX1=0.22uF, CX2=0.033uF, FOWX2 250-300Vac (For ENEC), 250Vac (For UL) 100 degree C min., X2 type

UL

UL

CX1=0.22uF, CX2=0.033uF, 275Vac (For ENEC), 250Vac (For UL) 110 degree C, X2 type,

FOWX2

UL

CX1=0.22uF, CX2=0.033uF, FOWX2 275Vac or 305Vac (For ENEC10 and VDE) 105 degree C, X2 type, Comply with IEC 60384-14

UL

CX1=0.22uF, CX2=0.033uF, FOWX2 275 Vac or 305 Vac (For ENEC10 and VDE ), 250Vac or

UL

Issue Date:

2012-05-18 2012-07-05

Page 11 of 19

Report Reference #

E131881-A1485-UL

04f. X-Capacitor (CX1, CX2 ) (Alternate)

04g. X-Capacitor (CX1, CX2 ) (Alternate)

EUROPTRONIC (TAIWAN) INDUSTRIAL CORP (for UL) 1.PILKOR ELECTRONICS CO LTD (for UL) 2.Pilkor Electronics Ltd. (for ENEC, CQC) 3.RONG CHENG PILKOR ELEC.,LTD (for CQC) EPCOS Electronic Components S.A.

275Vac (for UL) 110 degree C, X2 type, Comply with IEC 60384-14 PCX2 339 CX1=0.22uF, CX2=0.033uF, 250Vac (for UL) and 305Vac (for ENEC), 105 degree C or 110 degree C, X2 type FOWX2 UL

05. Y-Capacitors (CY2, CY3, CY5)

B3292# (for VDE) B3292x-x2xxx* (for UL) B3292xx3xxx* (for UL) Murata Mfg. Co., Ltd. KX (for VDE, UL) Murata Manufacturing Co., Ltd. (for CQC)

CX1=0.22uF, CX2=0.033uF, FOWX2 305Vac (For VDE), 250Vac (for UL) 105 degree C, X2 type CY2=CY3=100pF max., CY5=1500pF max., 250Vac (for UL and CQC), 300Vac (for VDE), Y1 type and 125 degree C. CY2=CY3=100pF max., CY5=1500pF max., 250Vac , Y1 type, 125 degree C. FOWX2

UL

UL

05a. Y-Capacitors (CY2, Walsin Technology AH CY3, CY5 ) (Alternate) Corp. (for UL and VDE) Walsin Technology Corporation (for CQC) 05b. Y-Capacitors (CY2, TDK-EPC CD CY3, CY5) (Alternate) Corporation (for VDE), TDK-EPC CORP (for UL), TDK XIAMEN CO., LTD (for CQC), TDK-EPC Corporation (for CQC) 06. Line Filter (FL1) ---

FOWX2

UL

CY2=CY3=100pF max., CY5=1500pF max., 250Vac, Y1 type, 125 degree C.

FOWX2

UL

130 degree C. Refer to

--

--

4-01

Issue Date:

2012-05-18 2012-07-05

Page 12 of 19

Report Reference #

E131881-A1485-UL

07. Bleeder Resistors (R1, R2) 08. Bridge Rectifier (BD1) 09. Electrolytic Capacitor (C1) (For model PMT24V35W1AA, PML24V35W1AA, PMB24V35W1AA, PMT24V35W1AH, PML24V35W1AH, PMB24V35W1AH) 10. Electrolytic Capacitor (C1) (For model PMT24V50W1AA, PML24V50W1AA, PMB24V50W1AA, PMT24V50W1AH, PML24V50W1AH, PMB24V50W1AH) 11. Electrolytic Capacitor (C1) (For model PMT12V35W1AA,PML12V35W1AA,PMB12V35W1AA,PMT12V35W1AH, PML12V35W1AH,PMB12V35W1AH) 12. Electrolytic Capacitor (C1) (For model PMT12V50W1AA ,PML12V50W1AA ,PMB12V50W1AA ,PMT12V50W1AH ,PML12V50W1AH ,PMB-

----

----

enclosure 4-01 for details. 392K ohm, 1/4 W. 800V min., 4A min.

---

----

82uF, 400V min., 105 degree C -min.

--

--

120uF, 400V min., 105 degree C min.

--

--

Various

Various

100uF, 400V min., 105 degree C min.

--

UL

Various

Various

150uF, 400V min., 105 degree C min.

--

UL

Issue Date:

2012-05-18 2012-07-05

Page 13 of 19

Report Reference #

E131881-A1485-UL

12V50W1AH) 13. Transformer (T1)

Delta Electronics, MV-MP11602 Inc.; Delta Electronics (Dongguan) Co., Ltd.; Delta Power Solutions (India) PVT., Ltd.; Delta Electronics (Wuhu) Co., Ltd.; Delta Electronics (Chen Zhou) Co., Ltd.; Delta Electronics (Thailand) Public Co., Ltd.; Delta Electronics (Jiangsu) Co., Ltd. 13-1. Insulation System Delta Electronics, Inc. MP-130I 14. Thermistor (NTC31) SEMITEC CORP MF11A474J, MF11C474J 14a. Thermistor (NTC31) THINKING TTC-474 (Alternate) ELECTRONIC INDUSTRIAL CO LTD(for UL) Thinking Electronic Industrial Co., Ltd.(for CQC) 14b. Thermistor (NTC31) UPPERMOST TDC05D447 (Alternate) ELECTRONIC INDUSTRIES CO LTD 15. Transistors (Q1) (For --model PMT24V50W1AA, PML24V50W1AA, PMB24V50W1AA, PMT24V50W1AH, PML24V50W1AH, PMB24V50W1AH)

Open type construction with -ferrite core, see Enclosure 4-02 for detail.

--

4-02

Class B 470K ohm at 25 degree C 470K ohm at 25 degree C

OBJY2 XGPU2 XGPU2

UL UL UL

470K ohm at 25 degree C

XGPU2

UL

650V min., 8A-9A

--

--

Issue Date:

2012-05-18 2012-07-05

Page 14 of 19

Report Reference #

E131881-A1485-UL

15a. Transistors (Q1) (For model PMT24V35W1AA, PML24V35W1AA, PMB24V35W1AA, PMT24V35W1AH, PML24V35W1AH, PMB24V35W1AH) 16. Optocoupler (IC32, IC33 )

--

--

600V min., 5.4A-10A

--

--

RENESAS ELECTRONICS CORPORATION Everlight Electronics Co., Ltd.

PS2561DL1-1

16a. Optocoupler (IC32, IC33 ) (Alternate)

16b. Optocoupler (IC32, IC33 ) (Alternate)

16c. Optocoupler (IC32, IC33 ) (Alternate)

Sharp Corp Electronic Components and Devices Group (for UL) Sharp Corporation (for VDE, S) TOSHIBA CORP, TLP781/TLP781F dti>0.5 mm, ext. cr. > 8 mm, int FPQU2 SEMICONDUCTOR cr. > 5 mm, isolation: AC CO DISCRETE 3000V, 115 degree C SEMICONDUCTOR DIV (for UL) Toshiba Corporation Semiconductor & Storage Products Company (for VDE) Toshiba Corporation Semiconductor Company (for S) Toshiba Corporation

dti.>0.4 mm, ext. cr.>8.0mm, FPQU2 thermal cycling test, 110 degree C, isolation: AC 3000V min. EL816 (for UL and dti.=0.5mm, ext. cr.=7.7mm, int. FPQU2 CQC) EL816 V cr.=6.0mm, 110 degree C, (for VDE) EL816. isolation: AC 3000V min. (for FI) PC123 dti>0.4mm, thermal cycling test, FPQU2 ext>8.0mm, isolation: AC 3000V, 110 degree C

UL

UL

UL

UL

Issue Date:

2012-05-18 2012-07-05

Page 15 of 19

Report Reference #

E131881-A1485-UL

17. Heat sink (HS1,HS2 ) (For model PMT24V50W1AA, PML24V50W1AA, PMB24V50W1AA, PMT24V50W1AH, PML24V50W1AH, PMB24V50W1AH, PMT12V35W1AA, PMT12V35W1AH) 18. Metal Case -(Chassis) (for model PMT-24V50W1AA, PMT-24V35W1AA, PML-24V50W1AA, PML24V35W1AA, PMT24V50W1AH, PMT24V35W1AH, PML24V50W1AH, PML24V35W1AH, PMT12V50W1AA, PMT12V50W1AH, PML12V50W1AA, PML12V50W1AH, PML12V50W1AA, PML12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH, PML-12V35W1AA, PML12V35W1AH, PML12V35W1AA, PML12V35W1AH) 18a. Metal Case -(Chassis) (Alternate) (for model PMT-

Semiconductor Company (for CQC) --

--

Aluminum, see Enclosure Diagrams 4-03 for dimension details.

--

--

4-03

--

SPCC, min. 1.0mm thickness. see Enclosure Diagrams 4-04 for dimension details

--

--

4-04

--

SECC, min. 0.6mm thickness, see Enclosure Diagrams 4-04 for dimension details

--

--

4-04

Issue Date:

2012-05-18 2012-07-05

Page 16 of 19

Report Reference #

E131881-A1485-UL

24V50W1AA ,PMT24V35W1AA,PML24V50W1AA ,PML24V35W1AA, PMT24V50W1AH ,PMT24V35W1AH, PML24V50W1AH, PML24V35W1AH, PMT12V50W1AA, PMT12V50W1AH, PML12V50W1AA, PML12V50W1AH, PML12V50W1AA, PML12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH, PML-12V35W1AA, PML12V35W1AH, PML12V35W1AA, PML12V35W1AH) 18b. Metal Case -(Chassis) (Alternate) (for model PMT24V50W1AA ,PMT24V35W1AA,PML24V50W1AA ,PML24V35W1AA, PMT24V50W1AH ,PMT24V35W1AH, PML24V50W1AH ,PML24V35W1AH, PMT12V50W1AA, PMT12V50W1AH, PML12V50W1AA, PML12V50W1AH, PML12V50W1AA, PML12V50W1AH,

--

AL1100, min. 1.5mm thickness, -see Enclosure Diagrams 4-04 for dimension details

--

4-04

Issue Date:

2012-05-18 2012-07-05

Page 17 of 19

Report Reference #

E131881-A1485-UL

PMT-12V35W1AA, PMT-12V35W1AH, PML-12V35W1AA, PML12V35W1AH, PML12V35W1AA, PML12V35W1AH) 19. Metal Case (Cover) -(for model PMT24V50W1AA, PMT24V35W1AA, PMT24V50W1AH, PMT24V35W1AH, PMT12V50W1AA, PMT12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH) 19a. Metal Case (Cover) -(Alternate) (for model PMT-24V50W1AA, PMT-24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH, PMT-12V50W1AA, PMT-12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH) 19b. Metal Case (Cover) -(Alternate) (for model PMT-24V50W1AA ,PMT-24V35W1AA, PMT-24V50W1AH ,PMT-24V35W1AH, PMT-12V50W1AA, PMT-12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH)

--

SGCC or SECC or SPCC, min. -0.6mm thickness. see Enclosure Diagrams 4-05 for dimension details

--

4-05

--

SECC, min. 0.6mm thickness, see Enclosure Diagrams 4-05 for dimension details

--

--

4-05

--

SPCC, min. 1.0mm thickness, see Enclosure Diagrams 4-05 for dimension details

--

--

4-05

Issue Date:

2012-05-18 2012-07-05

Page 18 of 19

Report Reference #

E131881-A1485-UL

Issue Date:

2012-05-18 2012-07-05

Page 19 of 19

Report Reference #

E131881-A1485-UL

Enclosures
Type Photographs Photographs Photographs Photographs Photographs Photographs Photographs Diagrams Diagrams Diagrams Diagrams Diagrams Schematics + PWB Manuals Miscellaneous Miscellaneous 7-04 7-07 Orientation on test informationb Model difference (PMT-24V50W1AA, PMT-24V35W1AA, PML24V50W1AA, PML-24V35W1AA, PMB-24V50W1AA, PMB24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH, PML24V50W1AH, PML-24V35W1AH, PMB-24V50W1AH, PMB24V35W1AH) Model difference (PMT-12V50W1AA, PMT-12V50W1AH, PMB12V50W1AA, PMB-12V50W1AH, PML-12V50W1AA, PML12V50W1AH, PML-12V50W1AA, PML-12V50W1AH) Supplement Id 3-01 3-02 3-03 3-04 3-05 3-06 3-07 4-01 4-02 4-03 4-04 4-05 5-01 Description Overall view, top Overall view, connector Overall view, side Overall view, connector PWB top PWB top PWB bottom FL1 Spec T1 Spec HS1, HS2 Chassis Cover PCB layout

Miscellaneous

7-08

File

E131881

Vol. X7

Sec. A1485

PHO-01

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-02

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-03

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-04

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-05

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-06

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

PHO-07

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-01(Page 1)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-01(Page 2)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-01(Page 3)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-02(Page 1)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-02(Page 2)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-02(Page 3)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-02(Page 4)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-02(Page 5)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-03

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-04

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

DIA-05

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

SCH-01(Page 1)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

SCH-01(Page 2)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-04

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-07

Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-08(Page 1)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-08(Page 2)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-08(Page 3)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-08(Page 4)Issued: 2012-05-18

File

E131881

Vol. X7

Sec. A1485

MIS-08(Page 5)Issued: 2012-05-18

Issue Date:

2012-05-18

Page 1 of 4 Test Record

Report Reference #

E131881-A1485-UL

Revision Date: 2012-07-05

Test Record No. 1


- The manufacturer submitted representative production samples of SWITCHING POWER SUPPLY, Models PMT-24V50W1AA, PMT-24V35W1AA, PML-24V50W1AA, PML-24V35W1AA, PMB-24V50W1AA, PMB-24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH, PML-24V50W1AH, PML-24V35W1AH, PMB-24V50W1AH, PMB-24V35W1AH - Unless otherwise noted in the list of tests, all tests were conducted by Delta Electronics Inc., Chung Li, Taoyuan Hsien, Taiwan under the CTDP. - Only the following tests were deemed necessary. - Test performed on Model PMT-24V50W1AA were considered to be representative of Models PMT-24V35W1AA, PML-24V50W1AA, PML-24V35W1AA, PMB-24V50W1AA, PMB-24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH, PML-24V50W1AH, PML-24V35W1AH, PMB-24V50W1AH, PMB-24V35W1AH - The results of this investigation, including construction review and testing, indicate that the products evaluated comply with the applicable requirements in the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA-C22.2 No. 60950-1-07, Second Edition and UL 60950-1, Second Edition issued March 27, 2007, including revisions through revision dated December 19, 2011. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. -The following tests conducted in accordance with UL 60950-1, Second Edition issued March 27, 2007, including revisions through revision dated December 19, 2011, Information Technology Equipment, Including Electrical Business Equipment were considered representative of the same tests required by Canadian Standards, CAN/CSA-C22.2 No. 60950-1-07, Second Edition , Information Technology.

Issue Date:

2012-05-18

Page 2 of 4 Test Record

Report Reference #

E131881-A1485-UL

Revision Date: 2012-07-05

The following tests were conducted: Test End Product Reference Page General Guidelines Power Supply Reference Page Input: Single-Phase (1.6.2) Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10) Capacitance Discharge (2.1.1.7) SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1) Limited Current Circuit Measurement (2.4.1, 2.4.2) Protective Bonding I (2.6.3.4, 2.6.1).7) Protective Bonding II (2.6.3.4, 2.6.1) Humidity (2.9.1, 2.9.2, 5.2.2) Determination of Working Voltage; Working Voltage Measurement (2.10.2) Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6) Transformer and Wire /Insulation Electric Strength (2.10.5.13) Heating (4.5.1, 1.4.12, 1.4.13) Touch Current (Single-Phase; TN/TT System) (5.1, Annex D) Electric Strength (5.2.2) Component Failure (5.3.1, 5.3.4, 5.3.7) Power Supply Output Short-Circuit/Overload (5.3.7) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following tests were waived: Test Transformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1) Rationale for Waiving Waived by power supply output short-circuit/Overload test for reference only for reference only Testing Location/Comments

Issue Date:

2012-05-18

Page 3 of 4 Test Record

Report Reference #

E131881-A1485-UL

Revision Date: 2012-07-05

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system. Type Attachment Datasheet Attachment Supplement Id 2-01 2-02 2-04 Description CRD DataSheet Refer Report

Issue Date:

2012-05-18

Page 4 of 4 Test Record

Report Reference #

E131881-A1485-UL

Revision Date: 2012-07-05

Test Record No. 2


- The manufacturer submitted a sample representing production of SWITCHING POWER SUPPLY, models PMT-24V50W1AA, PMT-24V35W1AA, PML-24V50W1AA, PML-24V35W1AA, PMB-24V50W1AA, PMB-24V35W1AA, PMT-24V50W1AH, PMT-24V35W1AH, PML-24V50W1AH, PML-24V35W1AH, PMB-24V50W1AH, PMB-24V35W1AH, PMT-12V50W1AA, PMT-12V50W1AH, PMB-12V50W1AA, PMB-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH, PMB-12V35W1AA, PMB-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, employing: 1. Change Line Filter (FL1) construction for all models. 2. Add alternate Thermistor (NTC31) source for all models: SEMITEC CORP, type MF11C474J. 3. Change components for models PMT-12V50W1AA, PMT-12V50W1AH, PMB-12V50W1AA, PMB-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PMT-12V35W1AA, PMT-12V35W1AH, PMB-12V35W1AA, PMB-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, see Enclosure ID 7-08 for details. - Tests performed on Model PMT-12V50W1AA and Model PMT-12V35W1AA were considered to be representative of Model(s) PMT-12V50W1AH, PMB-12V50W1AA, PMB-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PML-12V50W1AA, PML-12V50W1AH, PMT-12V35W1AH, PMB-12V35W1AA, PMB-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH, PML-12V35W1AA, PML-12V35W1AH. - Only limited tests were performed on Models PMT-12V50W1AA and PMT-12V35W1AA because of similarity in construction to Models PMT-24V50W1AA and PMT-24V35W1AA, previously evaluated unit. The following tests were conducted: Test End Product Reference Page General Guidelines Power Supply Reference Page Input: Single-Phase (1.6.2) Heating (4.5.1, 1.4.12, 1.4.13) Power Supply Output Short-Circuit/Overload (5.3.7) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system. Type Attachment Datasheet Supplement Id 2-05 2-06 Description CRD Datasheet Testing Location/Comments

Vous aimerez peut-être aussi