Académique Documents
Professionnel Documents
Culture Documents
HP
1 2 3 5 7.5 10 15 20 25 30 40 50 60 1 2 3 5 7.5 10 15 20 25 30 40 50 60
0.75
230 V series
18.5 10.281
460 V series
18.5 10.281
Note: Please only use DELTA resistors and recommended values. Other resistors and values will void DELTAs warranty. Please contact your nearest DELTA representative for use of special resistors. AC drive has 3 braking units with total of 12 braking resistors, so each braking unit uses 4 braking resistors.
121
APPENDIX B
B-2 PG Card (Refer to Pr.10-10 to 10-14 of related parameter settings) Section 1 Installation
1.1) 1 to 2HP (0.75kW to 1.5kW)
PG
-0
PG
Ca
rd
Te r
mi
na
ti c f a s of Pl a n d St
Co
1.2) 3 to 5HP (2.2kW to 3.7kW)
-01
o ntr
a bo
rd
PG
PG
Ca
rd
Te rm
in a
Con
tr
oa ol b
rd
122
APPENDIX B
Pla S t a st ic nd off
PG
Car
d Te
rm i
nal
123
APPENDIX B
Motor
M 3~
PG - 01
OC 12V
A B
A B PG
Factory Default
VP
TP 5V
+ 12V GND
DCM
R S T
M 3~
VFD-B
A B
O C 12V
A B PG
VP
TP 5V
+ 5V GND
RPM meter
124
APPENDIX B
3.2) Wiring Notes The control, power supply and motor leads must be laid separately. They must not be fed through the same cable conduit / trunking.
1 1 2 3 Please use a shield cable to prevent interference. Do not run control wire parallel to any high voltage AC power line (220 V and up). Connect shielded wire to DCM only. Recommended wire size 0.21 to 0.81mm2 (AWG24 to AWG18). Wire Length: Types of Pulse Generators Output Voltage Open Collector Line Driver Complementary
Wire Gauge
125
APPENDIX B
PG-01
Wiring Terminals
O C 12V
T P 5V
3.4)
O/P
TP 5V
0V
TP 5V
Open collector
VCC
OC 12V
O/P
OC 12V
TP 5V
0V
TP 5V
Line driver
OC 12V
OC 12V
Q
VCC
TP 5V
TP 5V
Complimentary
OC 12V O/P TP 5V 0V
OC 12V
TP 5V
126
APPENDIX B
Section 4 Dimensions
160.0 [62.99]
5.5[0.22]
VFD-B
VFD-B
JOG JOG
173.0 [6.81]
185.0 [7.28]
17 3.0 [6 .81 ]
RUN
STOP RESET
RUN
STOP RESET
WARNING
Do not connect AC power to output terminals(U.V.W.). Discharging time is greater than 1 minute. Do not inspect components unless inside "CHARGE" lamp is turned off. Read the instruction manual before operation.
WARNING:
Do not connect AC power to output terminals(U.V.W.). Discharging time is greater than 1 minute. Do not inspect components unless inside "CHARGE" lamp is turned off. Read the instruction manual before operation.
18 5.0 [7 .28 ]
8.8 [0.34]
5.5[0.22]
unit:mm [inches]
unit:mm [inches]
150.0[5.91] 135.0[5.32]
VFD-B
VFD-B
JOG
JOG
24 4.3 [9.62 ]
303 [11.94]
RUN
STOP RESET
RUN
STOP RESET
WARNING
Do not connect AC power to output terminals(U, V, W). Discharging time is greather than 1 minute. Do not inspect components unless inside "CHARGE" lamp is truned off. Read the instruction manual before operation.
WARNING
8.0 [0.32]
323 [12.72]
10.8 [0 .42 ]
2.5 [0 .10 ]
8.5 [0.33]
5.5 [0.22]
5.5 [0.22]
7.0 [0.28]
unit:mm [inches]
1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
unit:mm [inches]
127
8.5 [0.33]
APPENDIX B
VFD-B
JOG
JOG
MODE
PROG DATA
RUN
STOP RESET
RUN
STOP RESET
] 2 1 . 5 1 [ 0 . 4 8 3
] 0 9 . 5 1 [ 8 . 3 0 4
WARNING
Do not connect AC power to output terminals(U.V.W.). Discharging time is greater than 1 minute. Do not inspect components unless inside "CHARGE" lamp is turned off. Read the instruction manual before operation.
] 1 5 . 0 [ 0 . 3 1
10.0 [0.39]
unit:mm [inches]
unit:mm [inches]
128