Vous êtes sur la page 1sur 2

Engineering Specification Tank Gauging Instrumentation - Floating Roof Tank (Still Pipe)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Tag No. Quantity Service Tank Type Tank Size (Diameter x Hight) (m) Area Classification Tank Connection (Antenna) Area Classification Transmitter Safety Classification Pressure (bar.g) Temperature () Viscosity (Cp) Upper Lower Density (kg/m3) Upper Lower Free Water Level m Emulsion Volume (%) Certification Mounting type Process Connection Measuring Range Antenna Type Propagation mode Antenna Size Tank access Antenna surfaces Material Certification Mounting Measuring Type Measurement Principle Internal reference Frequency Ambient temperature Output Signal Power Supply Electrical Connection Lightning protection Enclosure Class Instrument accuracy Accuracy approvals Configuration Tag Number Type Display Cable Connection Wiring Installation Enclosure Class Tag Number Type Quantity Over all length Certification Element spacing Connection Size & Rating Electrical Connection Wire length Measuring Range Accuracy Bulb Material Bulb Diameter Mounting Output Water bottom sensor, Integrated Water bottom sensor length Anchor weight Model Mounting Output Wiring Manufacturer Model No. 1 STORAGE TANK FLOATING ROOF ROOF TANK 67.06 x 19 APPROVED FOR INSTALLATION IN ZONE 0 APPROVED FOR INSTALLATION IN ZONE 1 SIL 2 SUITABLE AND TV APPROVED MAX. NOR.

GENERAL

PROCESS CONDITIONS

none ATEX Cat 1/2 G FLANGE STILL PIPE 6" / 8" / 10" / 12" 0 ~ 40000 mm DOME LOW LOSS MODE (H11) AS PER PIPE SIZE EASY ACCESS THRUOGH ANTENNA / INDEPENDENT STILL PIPE EASY DRIP OFF (API 3.1B) EN 1.4436, 316SS/PTFE ATEX Cat 1/2 G, EEx d[ia] IIB T6 / Class 1, Div 1, Gr. C&D ON TANK CONNECTION RADAR FMCW DIGTAL, QUARTZ 10 GHz .-40 to +70 () TRL2 FIELDBUS 100-240V AC, 50-60Hz 2 x " NPT / Jbi with 3 x " & 3 x " NPT ISOLATION/VARISTOR 10KV IP 66 & 67 0.5 mm OIML THROUGH FIELD BUS MULTI-FUNCTION INDICATOR LCD 128x64 pixel graphic, digit height >11mm 1 x " & 1 x " NPT by external adapters 3 WIRE TO RADAR HEAD, MAX 100m ON TANK AT GRADE IP 66 & 67
Pt100 COMMON RETURN

TANK CONNECTION

RADAR TRANSMITTER HEAD

DISPLAY

(m)

TEMPERATURE SENSOR

() () (in.)

PRESSURE SENSOR P1

6 SPOT 18.7 IEC 751, ATEX 94/9/EC AS PER API CHAPTER 7.1/MANUFACTURERS STD. 2" CLASS 150 FLANGE / 3" CLASS 150 FLANGE LEADS/J-BOX 5m .-50 - + 120 0.25 1/6 DIN 316 SS 1 EXISTING 2"/3" OPENING/SEPARATE PIPE DIRECT CONNECT TO RADAR YES, SEE SEPARATE SPEC. 500 mm YES, TOP WEIGHT 5kg 3051S 2" FLANGE, ANSI 150# RF HART DIRECT CONNECTION TO RADAR Rosemount Tank Radar AB RTG 3950

NOTES :

Engineering Specification Tank Gauging Instrumentation - Water Level Sensor


1 2 3 4 5 6 7 Tag No. Quantity Service Tank Type Tank Size (Diameter x Hight) Area Classification 1 STORAGE TANK FIXED ROOF TANK 67.06 x 19 ATEX 94/9/EC MAX. PROCESS CONDITIONS Pressure (bar.g) Temperature () Viscosity (Cp) Upper Lower Density (kg/m3) Upper Lower Free Water Level m Emulsion Volume (%) Approvals Mounting type Active length/Measuring Range Accuarcy Operating temperature Max pressure Total sensor length Immersed Materials Sensor Model Output Calibration conditions Anchor weight NOTES : NOR.

GENERAL

(M)

none DEMKO 01 ATEX 131128X CE 0539 INTERGRAL WITH TEMPERATURE SENSOR 500 2 .0 - +120 6 Bar Active length + 140 mm AISI 316, FEP, PTFE & PEEK w. 30% glass OPEN/COAXIAL 4-20 mA, HART DIESEL (er 2.3) YES, TOP WEIGHT 5kg

mm mm ()

SENSOR

Vous aimerez peut-être aussi