Académique Documents
Professionnel Documents
Culture Documents
Page 1 of 8
cobas
roche.com cobas Worldwide Site Map Contact Text Size Home Products & Services Solutions Medical Value Analytes News & Events
Roche
Search for...
1. Products & Services 2. cobas u 411 urine analyzer Share Share on your social networks
ShareThis
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 2 of 8
Combur5 HC Test MODULAR ANALYTICS EVO MODULAR PRE-ANALYTICS EVO Multiplate analyzer Reflotron Plus system Urine Test Strips Urisys 1100 analyzer Urisys 2400 analyzer cobas IT 1000 application cobas b 101 POC System cobas b 121 system cobas b 123 POC system cobas b 221 system cobas bge link software cobas c 111 analyzer cobas h 232 POC system cobas p 312 pre analytical system cobas p 471 centrifuge unit cobas p 501 / cobas p 701 post-analytical units cobas p 612 / cobas p 512 pre-analytical systems cobas p 671 centrifuge unit cobas u 411 urine analyzer cobas 4000 analyzer series cobas 6000 analyzer series cobas 8000 modular analyzer series cobas academy cobas e-services hemo FEC test
Analytes
Clinical Chemistry / HIA Heterogeneous Immunology Molecular Diagnostics Point-of-Care Diagnostics
Indications
Anticoagulation Monitoring Therapy Diabetes Mellitus Heart Failure Kidney Disease Lipid Disorders Notes on preeclampsia, heart failure, chronic hepatitis B Urinary Tract Infection
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 3 of 8
Details view
Workflow
Fast and efficient workflow due to intuitive user guidance, optional barcode reader and flexible software Consolidated urine work area by connecting cobas u 411 with its sediment terminal Clear data management by consolidating test strip and microscopic results at cobas u 411 analyzer Flexibility of continuous test strip loading
Efficient
Selective analyzing by determination of multiple user defined microscopic parameters for flagging abnormal results and further microscopic follow up testing Calibration interval of 4 weeks reduces hands-on time and costs Optional barcode reader simplifies manual steps Automatic strip detection by two sensors reduces hands-on time and ensures reliable test strip recognition USB port and memory stick allow convenient archiving of data and easy updating of instrument software Approx. 600 test strips/h
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 4 of 8
Connected
Electronic documentation by uploading consolidated result to host Host interface supports transfer of lot numbers, expiry dates and control results to the host/EDP Bi-directional interface supports two protocol options (ASTM + and Urisys 2400 ASTM)
User-friendly
Allows entry of tracking information, including user-identification, and lot numbers for test strips, calibration strips and control materials Flexible sample ID entry via barcode reader, download from host or manual input meet your work area organization Two user-definable result flags permit easy identification of abnormal and microscopically relevant samples Customized result reporting with operator ID, selectable print order and conforming concentration units support your regulatory requirements Sensitivity ranges are adjustable according to your laboratory demands Intuitive user interface provides simple operation and clear data input Hygienic disposal of used test strips
High quality
Accurate and precise results High quality urine test strips as results of years of targeted research and development Ascorbic acid does not interfere with test strip (up to 750 mg/L), ensuring reliable results and no false-negatives in Glucose and Blood Compensation of strong intrinsic urine coloration reduces risk of false positive results
Related links
FAQ
Related Products
Combur5 HC Test Urine Test Strips Urisys 1100 analyzer Urisys 2400 analyzer
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 5 of 8
Related Diseases
Kidney Disease Urinary Tract Infection
Services
Contact us for further information System Components
cobas u 411 urine analyzer
Details view
Integrated Printer
Immediate and customized result reporting with possibility to change the order of test parameters on the printout as well as flagging of test results for rapid identification of pathological samples
IT Data Management
Elimination of manual documentation through export of data with host connectivity
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 6 of 8
Saving of sample, control and calibration data supports regulatory requirements, plus easy uploading of software and language updates
Related links
FAQ
Related Products
Combur5 HC Test Urine Test Strips Urisys 1100 analyzer Urisys 2400 analyzer
Related Diseases
Kidney Disease Urinary Tract Infection
Services
Contact us for further information Technical Specifications Instrument System Type Measuring system Throughput Memory User interface Printer Certificates Physical dimensions Weight Strips* Test strips Semi atomated urine test stripe analyzer Reflectance photometer Wave lengths: 470 nm, 555 nm, 620 nm Approx. 600 test strips/h 1000 sample results, 300 control results (3 levels) LCD touch screen (90x120 mm) Thermal printer CE, UL, CB, CUL Width: 42.5 cm Depth: 34.0 cm Height: 26.0 cm Approx. 12 kg Combur10 Test M
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 7 of 8
Parameters Calibration Connectivity System interfaces Host protocols Sample identification Accessories Type Supported barcode types
Specific gravity, pH, leukocytes, nitrite, protein, glucose, ketones, urobilinogen, bilirubin, blood (erythrocytes/hemoglobin), color Control-Test M calibration strip Serial interfaces to barcode reader, sediment terminal and PC/Host; USB Slot ASTM + and Urisys 2400 ASTM Sample ID via manual entry, barcode reader or download from host Barcode reader, Sediment Terminal Code 39, Code 128, NW 7 (Codabar), ITF (Interleaved 2 of 5)
*Combur-Test is marketed as Chemstrip in the United States and Canada Test Menu Parameter test strip Specific Gravity Reaction Clinical utility time Specific gravity is significant in the analysis of urine for narcotics or 60 sec. prescribed drugs. Acidic or alkaline urine might indicate the possibility of an acid-base pH 60 sec. imbalance. Persistently alkaline pH values can be an indication of a urinary tract infection. Leukocytes are a sensitive and early indicator of inflammatory diseases of the > kidneys and/or the > urinary tract. In chronic pyelonephritis it is 60-120 Leukocytes often the only symptom between acute episodes. It can also constitute Sec. important evidence for the presence of interstitial nephritis, urogenital tuberculosis or even tumors. Nitrite provides indirect evidence of nitrite-forming bacteria in the urine. The presence of nitrite in the urine is an important symptom of a bacterial > urinary tract infection. The most common cause of a urinary Nitrite 60 sec. tract infection is E. coli, which, along with most other pathogenic organisms of the urinary tract, converts the nitrate consumed in food into nitrite. Proteinuria is a frequent symptom in renal diseases. However, proteinuria is a non-specific symptom; it does not provide evidence of nephropathy, nor does its absence exclude nephropathy. Therefore, the Protein 60 sec. presence of urine protein should always be complemented by differential diagnosis. > Nephropathy (link to kidney disease) is a frequent complication in patients with diabetes or hypertension. Blood glucose levels of more than 180 mg/dl result in elevated glucose Glucose 60 sec. levels in the urine. Urinary glucose detection can be suppressed by the influence of ascorbic acid (vitamin C), if urine test strips are not protected against this influence. Metabolic disorders like > diabetes mellitus and specific dietary Ketone 60 sec conditions can lead to the excretion of ketone bodies in the urine. Elevated levels of urine urobilinogen can be caused by hepatitis, Urobilinogen 60 sec. cirrhosis or different hemolytic diseases. During all pathological processes that increase the concentration of conjugated serum bilirubin, urine bilirubin can also reach considerable Bilirubin 60 sec. high levels and can be caused by liver diseases like hepatitis, cirrhosis or biliary drainage blockage.
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013
Page 8 of 8
The excretion of erythrocytes (hematuria) in the urine may reveal > kidney disease or > urinary tract disorders. Hematuria is often caused by inflammation, but also occurs very often in the case of tumors, e.g. hypernephroma or bladder tumor, in renal damage and in most patients with urolithiasis even before they experience any pain symptoms. Urinary blood detection can be suppressed by the influence of ascorbic acid (vitamin C), if urine test strips are not protected against this influence.
1996-2012 Roche Diagnostics Limited 19.12.2012 Legal Statement Privacy Policy The content published on this website is not applicable to the US. 9/26/2012 This website contains information on products which is targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country. Please be aware that we do not take any responsibility for accessing such information which may not comply with any legal process, regulation, registration or usage in the country of your origin.
http://www.cobas.com/home/products_services/cobas_u_411_urine_analyzer.html
9/20/2013