STANDARD METHOD OF MEASUREMENT OF BUILDING WORKS FOR THE PHILIPPINES
This document is copyrighted to Davis Langdon & Seah Philippines Inc. under Copyright Registration No. A-99-964 dated 24 September 1999. All rights reserved by Davis Langdon & Seah Philippines Inc. No part of this publication may be reproduced or copied in any form without prior written permission from Davis Langdon & Seah Philippines Inc.
PSMM
STANDARD METHOD OF MEASUREMENT OF BUILDING WORKS FOR THE PHILIPPINES
Contents
Preface General Principles 01520 02050 02100 02152 02160 02200 02250 02361 02362 02363 02364 02370 02400 02500 02605 02660 02700 02830 02840 02900 03100 03200 03230 03231 03250 03300 03345 03400 03420 03500 Temporary Construction Demolition Site Preparation Shoring Excavation Support Systems Earthwork Diaphragm Walls Steel Sheet Piling Precast Concrete Piles Cast in Place Concrete Piles in Driven Casings Isolated Steel Piles Bored Cast in Place Piles Contractor Designed Piles Paving and Surfacing Utility Trenches and Structures Water Distribution (see 02700) Sewerage and Drainage Fencing and Gates External Furniture, Fixtures and Fittings Soft Landscaping Concrete Formwork Concrete Reinforcement Stressing Tendons Contractor Designed Stressing Tendons Concrete Accessories Cast in Place Concrete Concrete Finishing Precast Concrete Prestressed Precast Concrete Cementitious Decks and Toppings 04200 05100 05500 05700 06100 06160 06200 06400 06600 07110 07120 07190 07200 07300 07400 07510 07540 07900 08100 08210 08220 08400 08500 08610 08630 08700 08800 Unit Masonry Structural Steelwork Metal Fabrications Ornamental Metal (see 05500) Rough Carpentry Sheet and Board Linings and Panelling Finish Carpentry Architectural Woodwork Plastic Fabrications (see 05500) Sheet Membrane and Felt Waterproofing Asphalt and Fluid Applied Waterproofing Vapor Retarders Insulation Shingles and Roofing Tiles Manufactured Roofing and Siding Sheet Membrane and Felt Roofing (see 07110) Asphalt and Fluid Applied Roofing (see 07120) Sealants Metal Doors and Frames Wood Doors and Frames Plastic Doors and Frames (see 08100) Entrance Screens, Shopfronts and Frameless Glass Doors Metal Windows, Rooflights and Screens Wood Windows, Rooflights and Screens Plastic Windows, Rooflights and Screens (see 8500) Hardware Glazing 08900 09100 09205 09220 09250 09300 09550 09650 09680 09795 09900 09950 10150 10200 10270 10430 10440 10615 10800 11010 12600 13800 14000 15000 15300 15400 15440 16000 Index Curtain Walls Suspended Ceilings and Metal Support Systems Metal Lathing Plaster and Render Gypsum Board Tile and Slab Finishes Wood Flooring Resilient Flooring Carpet (see 9650) Trims, Division Strips, Nosings and the Like Painting Paperhanging Compartments and Cubicles Louvers and Vents Access Flooring Exterior Signs Interior Signs (see 10430) Demountable Partitions Toilet and Bathroom Accessories Maintenance Equipment (see 14000) Furniture and Accessories Building Automation Systems (see 16000) Conveying Systems Mechanical Installations Fire Protection Plumbing (see 15300) Plumbing Fixtures Electrical Installations
Preface
In recent years Quantity Surveying has become a well recognised and increasingly important profession in the construction industry in the Philippines. With Bills of Quantities being used more extensively for tender documentation it has become necessary to produce a local Standard Method of Measurement with the following aims in mind:(a) To produce a method of measurement which is based on local construction techniques and using local terminology (b) To produce a method of measurement based on local estimating methods (c) To produce a method of measurement which is consistent and easy to understand One of the means of achieving these aims was to produce this method of measurement based on the 16 division format used in North America for specifications and other project information. This is published in various forms by several U.S. and Canadian Organisations and has been widely adopted for use on projects in the Philippines. This method of measurement is based on the version published as "Masterformat, Master List of Titles and Numbers for the Construction Industry" produced by the Construction Specifications Institute (Canada) and Construction Specifications Canada. This will make a move towards greater uniformity in the production of information on construction projects making it more clear and easily understood by everyone involved. Prior to the introduction of this Standard Method of Measurement for the Philippines (PSMM), methods of measurement from other countries have been used which have not achieved the criteria above. With the launch of PSMM we hope that estimators will be able to price tenders accurately and with confidence and the administration of contracts will become easier. The PSMM was first published in March 1997. This second edition has incorporated comments and suggestion made to the first edition and also incorporates new sections for MEP works. In an effort to continuously improve this PSMM we welcome comments and suggestion from clients, consultants, contractors and interested bodies. This PSMM is produced exclusively for use by Davis Langdon & Seah and expressed written permission should be obtained from us should any third party wish to make use of it.
September 1999
General Principles
1. Introduction
1.1 This Standard Method of Measurement provides a uniform basis for measuring building works and embodies the essentials of good practice. Bills of Quantities shall fully describe and accurately represent the quantity and quality of the works to be carried out. More detailed information than is required by these rules shall be given where necessary in order to define the nature and extent of the required work. 1.2 The rules apply to measurement of proposed work and executed work. 1.3 Work is held to be carried out in accordance with the relevant Specification Clauses and drawings as though they were fully set out in the bills of quantities.
Classification tables
2.2 The classification table is split into four columns. Each item description shall identify the work with respect to one descriptive feature drawn from each of the first three columns in the classification table and as many of the descriptive features in the fourth column as are applicable to the item. 2.3 The lists in each column is not intended to be exhaustive. 2.4 Within the classification table, where a broken line is shown, the rules given above and below the broken line may be used as alternatives.
Supplementary rules
2.5 Within the supplementary rules everything above the bold horizontal line, which is immediately below the classification table heading, is applicable throughout that table. 2.6 Measurement rules set out when work shall be measured and the method by which quantities shall be computed. 2.7 Definition rules define the extent and limits of the work represented by a word or expression used 2.8 Coverage rules draw attention to particular incidental work which are held to be included in items 2.9 Supplementary Information defines information which is to be given in descriptions in addition to that contained in the classification table.
3. Quantities
3.1 Work is measured net as fixed in position except where otherwise stated in a measurement rule applicable to the work. 3.2 Dimensions used in calculating quantities shall be taken to the nearest 10mm (i.e. 5mm and over shall be regarded as 10mm and less than 5mm shall be disregarded). 3.3 Quantities shall be given to the nearest whole unit except that any quantity less than one unit shall be given as one unit. 3.4 Unless otherwise stated, where minimum deductions for voids are dealt with in this document they shall refer only to openings, block-outs or wants which are within the boundaries of measured areas. Openings, block-outs or wants which are at the boundaries of measured areas shall always be the subject of deduction irrespectively of size. 3.5 The requirement to measure separate items for widths or girths not exceeding a stated limit shall not apply where these widths are caused by voids
Work in repairs should be given separately and described as "in repairs" or further described as necessary to convey the nature of the repair work 4.4 Dimensions are stated in descriptions generally in the sequence length, width, height. Where ambiguity could arise, the dimensions shall be identified. 4.5 Information required by the rules of this method of measurement may be given in documents separate from the bills of quantities (e.g. drawings or specification). To assist the estimator a precise and unique cross reference should be given in place of the information within the description of the item concerned. 4.6 Where information required by the rules of this method of measurement are not included in descriptions, that part of the work is held to be at the Contractor's discretion unless noted otherwise in drawings or specifications. 4.7 Additional information should be given in descriptions in respect of any particular requirements or restrictions on the method of carrying out the work which are not otherwise required by the rules of this method of measurement 4.8 Where the nature of base is required to be stated the following general terms may be used: (a) Timber which is held to include plywood, blockboard and all other manufactured building boards (b) Metal which is held to include any type of metal (c) Concrete which is held to include concrete unit masonry, cementitous toppings and cementitous plaster 4.9 Work is held to include for fixing through any types of finishes applied to the surface of the base including glass, stone, ceramic and any other vulnerable materials 4.10 The use of a hyphen between two dimensions signifies a range of dimensions exceeding the first dimension stated but not exceeding the second.
4. Descriptions
4.1 Where work is required to be described as curved it should further be described as applicable where the curve is in more than one plane such as domed work Curved work is held to include: (a) all junctions between straight and curved work (b) work which is flewing except as otherwise provided 4.2 Where sizes are required to be given in descriptions they may be given in ranges where appropriate 4.3
Copyright : Davis Langdon & Seah Philippines Inc.
4.11 Unless otherwise specifically stated in the bills of quantities, the following shall be held to be included with all items: (a) Labor and all costs in connection therewith (b) Materials, goods and all costs in connection therewith (c) Assembling, hoisting, fitting and fixing materials and goods in position (d) Plant and all costs in connection therewith (e) Cutting (f) Waste and consumables (g) Design to the extent required by the specification and drawings (h) Establishment charges, overhead charges, profit, taxes and surtaxes 4.12 Where items are described as "fix only" the rates are held to include (a) to (h) above but excluding (b). The rate is also to allow for taking delivery on site, unloading, unpacking, returning packing and storing the materials and for all sundry materials for fixing such as adhesives, mortar for bedding, grouting materials, tying wire, bolts, nails, screws and ties and all consumables. 4.13 Work is held to include: (a) All temporary work as necessary and its subsequent removal including scaffolding, supports, protective screens and the like unless otherwise required by the rules (b) All permanent work as necessary in supports, fixings and the like which is not designed but required to carry out the items (c) Working in confined spaces (d) Giving all necessary notices to government department and utility companies (e) Obtaining all necessary licences and paying all fees and charges as necessary
7. Procedure where the drawn and specification information required by these rules is not available
7.1 Where work can be described and given in items in accordance with these rules but the quantity of work required cannot be accurately determined, an estimate of the quantity shall be given and identified as a provisional quantity. 7.2 Where work cannot be described and given in items in accordance with these rules it shall be given as a provisional sum. 7.3 Where provisional sums are given the Contractor will be deemed to have made due allowance in programming, planning and pricing preliminaries. 7.4 Where prime cost sums for the supply of materials are included in descriptions they are held to be the material cost delivered to street level of the site and the Contractor is to allow in the overall rate for waste on such materials and for all ancillary materials required for fixing such as mortar for bedding and jointing, adhesives, screws and other consumables. The prime cost will be expended at the discretion of the Project Manager and the adjustment to the overall rate will be the net difference between the prime cost sum stated in the description and the actual price paid per unit of measurement applied to the net quantity of the particular material as fixed in position.
appears.
9. Definitions
9.1 Where SMM rules describe work as "designed by the Structural Engineer" or "designed by the Mechanical Engineer" or "designed by the Electrical Engineer" it is defined as work which is fully designed and shown on plans and elevations in sufficient detail to measure the quantities and accurately describe the work 9.2 Where SMM rules describe "labors" they are defined as work in cutting, bending, drilling, shaping and the like 9.3 The term measured separately in an item description is a convention meaning not to be priced here 9.4 The term by Others shall mean works to be carried out by contractors (either the main contractor or other nominated sub-contractor or statutory authorities 9.5 The term equal and approved equivalent shall mean materials or equipment equal or better in quality/performance criteria to that stated in the specification and/or bidding drawings and subject to the approval of the Architect/Design Consultants 9.6 The term extra, extra for or extra over for preceding any item description shall mean additional item over and above what is already provided. It is deemed to exclude the price of item for which the extra item will replace.
8.2 Cross reference within the classification tables are given in the form: Number Section from first Number : column Example: 02200.1.4.1.1 02200 Earthwork Excavating Trenches Maximum depth < 2.00m Commencing level stated 8.3 An asterisk within a cross reference represents all entries in the column in which it appears. 8.4 The digit 0 within a cross reference represents no entries in the column in which it . Number from second column . Number from third column . Number from fourth column
FZ
C1 Work is held to include: (a) all necessary incidental work for the proper execution of the item (b) clearing away (c) making good all work disturbed
01520/1
02050/1
02050 Demolition
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 This section is for work to existing buildings involving the removal of existing materials (other than for bonding purposes), unless stated otherwise M2 Inserting new work is described following the rules in the relevant Sections DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION S1 Location S2 Any repairs or adaptations required for work to be set aside S3 Limits on making good where new work is included separately or is otherwise not required as part of the item S4 Owner's restrictions on method of carrying out the work including: (a) method of disposal of materials (b) method of shoring (c) scaffolding to be used S5 Where work is known to involve the removal of materials containing asbestos, toxic, dangerous or other hazardous materials it is so described
D1 Materials arising from demolitions shall become the property of the Contractor unless stated otherwise D2 Making good includes all labors and materials necessary to bring the disturbed area to the same face, color and texture and in the same materials as the surrounding work but excludes painting and decorating unless otherwise described
C1 Work is held to include: (a) shoring, needling, strutting and all other necessary supports including cutting away existing structures and finishes as necessary and making good after removal (b) dustproof screens, watering debris and all other work necessary to keep dust nuisance to a minimum (c) removal, relocation or adaptation of all attached and associated services, fixtures, fittings, finishes and all other work affected (d) disconnection of services (e) preparing for and jointing new work to existing (f) preparing exposed surfaces to receive new work (g) wedging and pinning (h) cutting out fixings (i) cutting back reinforcement (j) disposal of materials (k) making good all work disturbed (l) allowance for any credit for materials becoming the property of the Contractor (m) all necessary incidental work for the proper completion of the item
C2 Work is held to include the removal of asbestos, toxic, dangerous or other hazardous materials including all protective work or measures as necessary for their safe removal and for disposing to a dump site approved for the purpose C3 Setting aside includes for: (a) carefully removing, disconnecting, dismantling and reassembling (b) cleaning, oiling and adjusting (c) repairing damage caused during removal (d) provision of suitable storage CLASSIFICATION TABLE 1 Demolitions 1 Structures 2 Parts of structures 1 Dimensioned description sufficient for identification and levels to which structures are demolished Item 1 Setting aside materials to remain the property of the Owner 2 Setting aside materials for re-use 3 Leaving parts of existing structures temporarily in position to act as buttresses
02050/2
Copyright : Davis Langdon & Seah Philippines Inc.
02050/3
Copyright : Davis Langdon & Seah Philippines Inc.
02050/4
1 Detailed description
No
02100/1
02152/1
02152 Shoring
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Shoring associated with demolitions are held to be included with the demolitions items included in Section 02050 - Demolition DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) all necessary wedges, cramps, fastenings and bolts (b) welding and painting (c) all necessary incidental work for the proper execution of the item (d) clearing away (e) making good all work disturbed SUPPLEMENTARY INFORMATION S1 Kind and quality of materials
CLASSIFICATION TABLE 1 Shoring 1 Position and type of shoring and nature of structure item 1 Maintaining, duration stated 2 Adapting, details stated 3 Cutting away existing structures, details stated
CLASSIFICATION TABLE 1 Rock anchors 2 Soil nails 1 Dimensioned description No 1 Trial anchors M2 The lengths of tendons are measured between the outer ends of anchorages C1 Work is held to include: (a) drilling through any ground encountered including concrete, reinforced concrete, roots and all other obstructions and drilling at various depths and elevations (b) disposal of spoil off site (c) ducts, grouting, spacers and grout tubes (d) anchors, bolts, plates and the like (e) sheathing (f) stressing and distressing (g) protective coatings (h) all necessary incidental work for its proper execution (i) dismantling and clearing away C2 Provision of anchors, loading materials and all other work necessary for testing are held to be included
2 Tests
1 Details stated
No
02160/1
02160/2
02200 Earthwork
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Base and sub base courses to roads, sidewalks, walkways and pavements are measured in Section 02500 - Paving and Surfacing M2 Topsoil filling for landscaping is measured in Section 02900 - Soft Landscaping DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION S1 Kind and quality of materials
P1 The following information is provided, where available: (a) soil investigation results (b) ground water level and the date when it was established (c) location of underground services
C1 Work is held to include: (a) excavating in any ground encountered except as otherwise provided in this section (b) excavating around existing services (c) temporary support to existing services (d) removal of dead services (e) getting out excavated materials by any means necessary (f) grubbing up old roots (g) levelling or grading bottoms, trimming to slopes and trimming to vertical and sloping sides (trimming to surfaces against which concrete is directly cast is measured in accordance with 02200.10.1.*.*) (h) compacting bottoms and sides (i) protection to sloping surfaces (j) additional excavation to provide working space and backfilling thereto
02200/1
02200/2
2 To reduce levels
m3
1 Rock 2 Concrete
2 Breaking up existing hard surfaces, thickness stated if known 3 Excavating for soft spots including disposal and backfilling with approved granular material 3 Disposal 1 Topsoil 2 Excavated materials
m3
m3 m3
M5 The quantities given are the volume before excavating and no allowance is made for subsequent variations to volume
C3 The work is held to include for all multihandling to and from temporary spoil heaps as and if necessary C4 Disposal is held to include any type of excavated material or broken out materials-
4 Filling to beds
1 Thickness stated
1 Topsoil from excavations 2 Excavated material other than topsoil 3 Imported materials, details stated
M6 Filling is measured as equal to the volume of the void to be filled M7 The thickness of filling is measured as the thickness after compaction M8 Topsoil filling as part of soft landscaping is measured in Section 02900 - Soft Landscaping
D5 All materials from excavations are held to be suitable for filling. Where materials from excavations are not suitable the work is held to include approved imported materials as a substitute and disposal off site of unsuitable material D6 Filling to beds is filling of a constant thickness D7 Filling to make up levels is filling where the thickness varies D8 Filling to beds includes blinding beds
C5 Work is held to include: (a) all multi-handling to and from temporary spoil heaps as and if necessary (b) temporary retaining boards to edges and slopes (c) levelling, grading, trimming and compacting (d) handpacking as necessary (e) laying to falls, slopes and contours <15 C6 Filling to beds and filling to make up levels are held to include providing sand or other fine material across the surface to receive vapor barriers, concrete, asphalt and the like C7 Filling to make up levels is held to include for forming embankments or terraces
5 Backfilling to excavations 6 Filling to make up levels 7 Filling into planters and the like, position stated if not at ground level
m3
M9 Formation of slopes are only measured where the slope is >15 from horizontal and >15 from vertical D9 Battered faces are faces <15 from vertical
02200/3
02200/4
3 Soil poisoning
S4 Method of treatment
11 Removal of water
1 Keeping the site and all excavations thereon free from water by pumping or otherwise
item
CLASSIFICATION TABLE 1 Providing plant and equipment on site item C1 Providing plant and equipment is held to include the subsequent removal M1 The quantities given are the volume before excavating and no allowance is made for subsequent variations to volume C2 The following are held to be included: (a) support fluid (b) subsequent disposal of support fluid (c) disposal of excavated material off site (d) excavating in any ground encountered except as otherwise provided in this section (e) removal of dead services (f) getting out excavated materials by any means necessary (g) grubbing up old roots D1 Rock is defined as naturally occuring hard material which necessitates its removal by means of explosives, pneumatic equipment, wedges or chemical cracking and where its volume >1.00m3 S2 Details of support fluid S3 Limitations on method of disposal
m3
1 Breaking out existing materials 2 Breaking up existing hard surfaces, thickness stated if known
1 Rock 2 Concrete
m3 m
02250/1
02250/2
5 Concrete
m3
1 Details stated
M6 Construction joints are measured in accordance with Section 03250 - Concrete Accessories M7 Construction joints are only measured where designed by the Structural Engineer
C5 Construction joints not designed by the Structural Engineer and required for the Contractor's method of working are held to be included and include for associated formwork, fillers, sealants, waterstops and all other necessary work
10 Guide walls
1 Subsequently removed
M8 The lengths measured for guide walls are those of the diaphragm walls
C6 Work is held to include excavation, disposal, concrete, reinforcement, formwork and all other necessary work for the proper execution of the item C7 Provision of platforms, loading materials and all other work necessary are held to be included
11 Tests
1 Details stated
No
02250/3
02361/1
CLASSIFICATION TABLE 1 Providing plant and equipment on Site item C4 Providing plant and equipment is held to include the subsequent removal 1 Subsequently withdrawing 2 Trial piles
2 Supplying piles
1 Dimensioned description
02362/1
2 Supplying piles
No
1 Trial piles
M1 The payable length for supply of piles shall be based on the actual number and length delivered and subsequently incorporated into the works. However payment shall be based on initial and extension piles being supplied in the most economic commercially available lengths to suit the required overall length of the designed pile subject always to the instructions of the Project Manager M1 Measured from the shoe point in contact with the ground when pitched to the shoe point when driven
C3 Supplying piles is held to include: (a) molds (b) reinforcement (c) pretensioning (d) heads, shoes and rock shoes where not designed by the Structural Engineer (e) all necessary joint to extension piles C4 Preparing tops to receive pile extensions is held to be included
3 Driving piles
C5 Driving is held to include: (a) driving through any ground encountered (b) driving through rock, concrete, reinforced concrete, roots and all other obstructions including excavation and breaking out as necessary (c) disposal of spoil off site
4 Pre-boring
1 Trial piles
C6 Pre-boring is held to include (a) grouting up voids between sides of piles and bores (b) boring through any ground encountered (c) boring through rock, concrete, reinforced concrete, roots and all other obstructions (d) disposal of excavated material off site
S2 Type of grout
1 Dimensioned description
No
1 Trial piles
M3 Heads, shoes and rock shoes are only measured where designed by the Structural Engineer
02362/2
02362/3
No
1 Trial piles
C7 Cutting off tops of piles is held to include: (a) integration of reinforcement into pile caps or ground beams including cleaning, cutting and bending (b) disposal C8 Temporary pile caps and provision of all anchors, platforms, loading materials and the like are held to be included
9 Pile tests
1 Details stated
No
1 Trial piles
CLASSIFICATION TABLE 1 Providing plant and equipment on Site item C3 Providing plant and equipment is held to include the subsequent removal 1 Subsequently withdrawing 2 Trial piles C4 Supplying piles is held to include heads, shoes and rock shoes where not designed by the Structural Engineer M1 Measured from the shoe point in contact with the ground when pitched to the shoe point when driven C5 Driving is held to include: (a) driving through any ground encountered (b) driving through rock, concrete, reinforced concrete, roots and all other obstructions including excavation and breaking out as necessary (c) excavation within casings (d) disposal of spoil off site
No
02363/1
02363/2
4 Concrete filling
1 Trial piles
M2 Measured from the bottom of the driven casing to the cut-off level of the pile
C6 Concrete filling is held to include: (a) additional concrete which is subsequently cut off (b) additional concrete for filling fissures encountered during piling
1 Dimensioned description
No
1 Trial piles
M3 Heads, shoes and rock shoes are only measured where designed by the Structural Engineer C7 Enlarging bases is held to include: (a) additional excavation and disposal (b) additional concrete M4 Reinforcement is measured in accordance with Section 03200 Concrete Reinforcement C8 Cutting off tops of piles is held to include: (a) integration of reinforcement into pile caps or ground beams including cleaning, cutting and bending (b) disposal C9 Temporary pile caps and provision of all anchors, platforms, loading materials and the like are held to be included
No
1 Trial piles
9 Reinforcement
kg
1 Trial piles
No
1 Trial piles
11 Pile tests
1 Details stated
No
1 Trial piles
CLASSIFICATION TABLE 1 Providing plant and equipment on Site item C3 Providing plant and equipment is held to include the subsequent removal 1 Coatings, details stated 2 Subsequently withdrawing 3 Trial piles
2 Supplying piles
No
02364/1
02364/2
3 Driving piles
M1 Measured from the point in contact with the ground to the point when driven
C4 Driving is held to include: (a) jointing to extend piles (b) driving through any ground encountered (c) driving through rock, concrete, reinforced concrete, roots and all other obstructions including excavation and breaking out as necessary (c) disposal of spoil off site
1 Trial piles
No
1 Trial piles
C5 Cutting off tops of piles is held to include disposal C6 Temporary pile caps and provision of all anchors, platforms, loading materials and the like are held to be included
6 Pile tests
1 Details stated
No
1 Trial piles
3 Concrete filling
1 Trial piles
M3 Measured from the bottom of the bore to the cut-off level of the pile
No
1 Trial piles
02370/1
02370/2
No
1 Trial piles
7 Pile tests
1 Details stated
No
1 Trial piles
CLASSIFICATION TABLE 1 Providing plant and equipment on Site item C1 Providing plant and equipment is held to include the subsequent removal 1 Designed length stated 2 Battered 3 Trial piles M2 Lengths are only given where designed by the Structural Engineer M1 Lengths and depths are measured to the cut off levels of the piles C2 Contractor designed piles are held to include: (a) driving or boring through any ground encountered (b) driving or boring through rock, concrete, reinforced concrete, roots and all other obstructions including excavation and breaking out as necessary (c) disposal of spoil off site (d) all work included in Sections 02361 to 02370 as applicable C3 Temporary pile caps and provision of all anchors, platforms, loading materials and the like are held to be included S1 Types of piles, method of driving or boring and other Structural Engineer's requirements
1 Load to be carried
1 Commencing level stated and depth of top of piles below commencing level
No
3 Pile tests
1 Details stated
No
1 Trial piles
02400/1
02400/2
item
C4 Design information is held to include: (a) design drawings (b) working drawings (c) structural calculations (d) all other information necessary to evaluate the Contractor's design (e) presentation of design information to the Project Manager and Structural Engineer and incorporating any design revisions as requested
02500/1
02500/3
15 Channel covers
M7 Precast concrete channel covers are measured in accordance with Section 03400 Precast Concrete M8 Metal channel covers are measured in accordance with Section 05500 - Metal Fabrications
16 Geotextiles
M9 No deduction is made for voids < 0.50m M10 Geotextiles are measured the net area covered with no allowance for laps
C6 Work is held to include: (a) laying to falls, currents, slopes and to vertical surfaces (b) extra material for laps
17 Surface markings
M11 Surface markings are measured in accordance with the rules in Section 09900 Painting
CLASSIFICATION TABLE 1 Excavating trenches 1 Services < 200mm diameter 2 Services > 200mm diameter, size stated 3 More than one service, sizes stated 1 Average depth 250mm 2 and thereafter in stages of 250mm m 1 Commencing level 2 Curved D1 If the service is laid in a duct it is the diameter of the duct which is given C2 Work is held to include: (a) backfilling with selected excavated material or as otherwise described (b) disposal of surplus excavated material off site S2 Backfilling material where other than selected excavated material
02605/1
02605/2
1 Curved
D2 If the service is laid in a duct it is the diameter of the duct which is given
5 Vertical casings
6 Ducts
1 Nominal size
M1 Ducts are measured over all bends, junctions and similar fittings
C4 Ducts are held to include for: (a) all jointing materials (b) brackets for fixing to walls, chamber sides and the like (c) concrete thrust blocks D3 Fittings include bends, junctions, reducers, connectors, adaptors and the like C5 Fittings are held to include: (a) extra joints on ducts (b) concrete thrust blocks C6 Work is held to include: (a) excavation (b) backfilling with selected excavated material or as otherwise described (c) disposal of surplus excavated material (d) connections of ducts/services to the chamber (e) all work necessary to complete the chamber
1 Fittings
1 Dimensioned description
No
1 Wrapping
8 Chambers
1 Dimensioned description
No
m3
M2 The volume of breaking out existing materials in trenches is based on the width of the beds in the trenches. Where there are no beds the width to be taken is the nominal size of the service, or the duct within which the service runs where applicable, plus 300mm 1 Reinstating to match existing M3 Lengths are measured across chambers
D4 Rock is defined as naturally occuring hard material which necessitates its removal by means of explosives, pneumatic equipment, wedges or chemical cracking and where its volume >1.00m3
C7 Removal and reinstatement of curbs and channels are held to be included C8 Work is held to include additional breaking up and reinstatement to and around chambers
1 Details stated
No
02605/3
02700/1
CLASSIFICATION TABLE 1 Excavating trenches 1 Pipes < 200mm diameter 2 Pipes > 200mm diameter, size stated 3 More than one pipe, sizes stated 1 Average depth 250mm 2 and thereafter in stages of 250mm m 1 Commencing level 2 Curved C2 Work is held to include: (a) backfilling with selected excavated material or as otherwise described (b) disposal of surplus excavated material off site S2 Backfilling material where other than selected excavated material
2 Beds
1 Curved
5 Vertical casings
1 Thickness of surround
6 Pipes
1 Nominal size
M3 Pipes are measured over all bends, junctions and similar fittings
C4 Pipes are held to include for: (a) all jointing materials (b) brackets for fixing to walls, manhole sides and the like (c) concrete thrust blocks D1 Fittings include bends, junctions, reducers, connectors, adaptors and the like C5 Fittings are held to include: (a) extra joints on pipes (b) concrete thrust blocks
1 Fittings
1 Dimensioned description
No
1 Wrapping
M4 Reducing fittings are measured extra over the largest of the pipes on which they occur and include for separate reducers where a fitting of the required sizes is not avavailable
8 Pipe accessories
1 Dimensioned description
No
9 Equipment
D2 Accessories include catch basins, area drains, ground clean outs, valves, hydrants, grease interceptors and the like D3 Equipment includes tanks, pumps and the like
C6 Accessories are held to include: (a) connections to pipes and bedding in concrete (b) concrete thrust blocks
02700/2
02700/3
No
1 Backdrops
D4 The depth given is that from the cover level to the invert level
C7 Work is held to include: (a) excavation (b) backfilling with selected excavated material or as otherwise described (c) disposal of surplus excavated material (d) connections of pipes (e) all work necessary to complete the manhole, chamber or septic tank
m3
M5 The volume of breaking out existing materials in trenches is based on the width of the beds in the trenches. Where there are no beds the width to be taken is the nominal size of the pipe plus 300mm 1 Reinstating to match existing M6 Lengths are measured across manholes and other chambers
D5 Rock is defined as naturally occuring hard material which necessitates its removal by means of explosives, pneumatic equipment, wedges or chemical cracking and where its volume >1.00m3 C8 Removal and reinstatement of curbs and channels are held to be included C9 Work is held to include additional breaking up and reinstatement to and around manholes and other chambers S6 Type and thickness of surfacing, base and sub-base courses, if known
14 15
1 Details stated
Item
C10 Testing and commissioning is held to include: (a) provision of water, fuel, gas, electricity and other supplies provision of test certificates making good all defects and retesting as necessary
(b) (c)
02700/4
02830/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Surface treatments prior to erection stating whether on or off site
CLASSIFICATION TABLE 1 Fencing 1 Dimensioned description 1 Type, spacing, height and depth of supports m 1 Fencing set out to a curve but straight between posts 2 Curved fencing, radii stated 3 Fencing to ground sloping > 15 from the horizontal D2 The height of fencing is measured from the surface of the ground (or other stated base) to the top of the infilling or, where there is no infilling, to the top wire or rail D3 Curved fencing is fencing curved between supports C2 Work is held to include: (a) ends, angles, bends and all other changes in direction (b) excavating holes for supports (c) backfilling with selected excavated material or as otherwise described (d) disposal of surplus excavated material off site S3 Type and size of footings to supports S4 Where not supported by footings, method of fixing and nature of base S5 Backfilling material where other than selected excavated material
D4 Special supports are end posts, angle posts and the like which differ in nature to the general design D5 Integral gate posts are those integral with the fencing D6 The height of supports is the height above the surface of the ground or other stated base D7 The depth of supports is the depth below the surface of the ground or other stated base 5 Gates 1 Dimensioned description No 1 Hardware, stated
(e) formwork to footings (f) all necessary supports, fixings and ancillary work C3 Gate posts are held to include stops, fixings and all other accessories
2 Extra over for special supports 3 Extra over for integral gate posts 4 Independent gate posts
1 Type stated
No
C4 Gates are held to include gate stops, gate ctches and independent gate stays and their associated works
No
02830/2
02840/1
CLASSIFICATION TABLE 1 Topsoil M2 Topsoil is measured in accordance with Section 02200 Earthwork 1 Depth stated m 1 Weeding, details stated D1 Surface applications include herbicides, selective weedkillers, peat, manure, compost, fertiliser, sand and the like C1 Cultivating is held to include the removal of stones C2 Surface applications are held to include working in if required
2 Cultivating
3 Surface applications
4 Seeding
1 Rate stated
C3 Seeding and turfing are held to include work to contours and slopes <15 C4 Seeding is held to include raking or harrowing in and rolling
5 Turfing
1 Width stated
02900/1
02900/2
S3 Size of pits, holes and trenches, excavated or formed S4 Details of any supports, ties, guards, wrapping and other sundry work S5 Backfilling material where other than selected excavated material S6 For relocation of trees, shrubs and plants details of: (a) existing and new locations (b) temporary storage including details of nurseries and duration of storage
1 Height
No
10 Hedge plants
1 Height stated
No
2 Height, spacing, number of rows, and layout stated 11 Herbaceous plants 1 Size stated
No
No
m No
No
No
2 Beds
1 Thickness stated
17 Temporary fencing
M3 Temporary fencing is only measured here where specifically required and then in accordance with Section 02830 - Fencing and Gates item C7 Work is held to include: (a) Watering, fertilisation, cultivation, cutting, pruning and all other work to maintain the trees, plants and grass for the duration stated (b) Replacing dead, damaged, diseased or otherwise defective trees, plants and grass S7 Specific requirements for watering, fertilisation, cultivation, cutting and pruning
1 Duration stated
02900/3
03100/1
3 Sloping 4 Curved
D4 Ground beams include tie beams and the like D5 Edges of mat foundations includes sides of lift pits and the like formed within the mat foundation
5 Columns
M8 Where columns are attached to walls and the concrete is the same grade in both, formwork to columns is measured to the projecting faces and margins of the columns only M9 If the width of a column is > four times its thickness it is classified as a wall
6 Walls 7 Retaining walls 8 Parapet walls and planter walls 9 Soffits of slabs 10 Soffits of landings 11 Soffits of spiral ramps 2 Slab thickness > 200mm, thickness stated in further stages of 200mm 2 Thereafter in 1.50m stages 1 Slab thickness < 200mm 1 Height to soffit < 3.50m
D7 Formwork to soffits of slabs include: (a) soffits of ramp slabs (b) soffits of landings occurring at floor level D8 Soffits of landings are soffits of intermediate landings to staircases
1 Size of recesses and profile, centers of recesses and overall slab thickness stated
M11 Measured the flat area of the soffit with no allowance for the profile of the recesses
D9 Soffits of waffle and troughed slabs include margins whose width is < 500mm
03100/2
03100/3
S3 Curved beams are separated by those curved on plan and those curved on elevation
17 Edges of walls 18 Soffits of walls 19 Edges of slab on grade, beds and the like 20 Edges of suspended slabs 21 Edges of machine bases and plinths 22 Sides of upstand beams 23 Sides of curbs, upstands, zocalos and the like 24 Edges of drop panels 25 Steps in top surfaces 26 Steps in soffits 27 Risers 28 Open strings
m m
1 Undercut
1 Curved
29 Top formwork
1 Curved
M13 Top formwork is measured to surfaces sloping >15or where otherwise specifically required C4 Channels are held to include outlets M14 Work is not differentiated between horizontal, vertical and sloping surfaces
30 Channels
1 Curved
31 Sunbreakers, fins, hoods, fascias, cantilevered planter boxes and the like 32 Copings 33 Corbels 34 Balustrades 35 Counters, shelves and the like 36 Louvers 37 Rounded edges 38 Moulded edges 39 Ornamental features to fair faced concrete 1 Grooves 2 Rebates 3 Drips 4 Chamfers and splays 5 Recesses 40 Sump pits 41 Complex shapes 1 Dimensioned description 1 Size and shape stated 1 Size and shape stated
m m No
1 Curved
1 Curved
1 Curved
M15 Ornamental features are only measured to formwork to produce a fair faced finish
No
1 Left in 2 Permanent
03100/4
03200/1
M3 Where locations are required they should follow the classifications in Section 03300 - Cast in Place Concrete CLASSIFICATION TABLE 1 Bar 1 General reinforcement 2 Links, stirrups and binders 3 Spacers and chairs designed by the Structural Engineer 1 Diameter stated and location kg 1 Bent to suit curved concrete 2 Helical 3 > 12m in length, given in stages of 3m D1 Where bars are shown in lengths >12m they are measured in 12m lengths with allowance for laps at joints unless specifically required by the Structural Engineer to be in other lengths D2 Bar reinforcement includes dowel bars C2 The contractor is to allow in his rates for any additional laps/slices required to suit his construction methodology
item
M4 This item is included in the bills of quantities, even if spacers and chairs are designed by the Structural Engineer, so that any additional spacers and chairs required by the Contractor can be allowed for D3 Special joints include welded or screwed sleeve joints 1 Bent to suit curved concrete work 2 In casings to structural steel, columns, beams and girders M5 Fabric is measured the net area covered with no allowance for laps M6 No deduction is made for voids < 1.00m C3 Fabric reinforcement is held to include: (a) notching around obstructions (b) extra material for laps (c) spacers and chairs whether designed by the Structural Engineer or not C4 Fabric in casings to structural steel, columns, beams and girders is held to include welding to the structural steel member
5 Special joints designed by the Structural Engineer 2 Fabric 1 Dimensioned description or weight per m and location
No
03200/2
03230/1
CLASSIFICATION TABLE 1 Tendons 1 In suspended slabs 2 In beams 1 Number, length and diameter of strand, wire or bars which make up the tendons No 1 Curved M1 Lengths are given as a straight line between outer faces of anchorages with no allowance for undulations along the length of the tendon C1 Work is held to include: (a) ducts and grouting to ducts (b) anchorages including anchor plates, cones, wedges and the like (c) sheathing (d) supports to the material used in the formation of ducts (e) forming and grouting of air holes (f) degreasing, straightening, cutting to lengths and assembling tendons and cutting off ends after tensioning (g) formwork to form recesses for anchorages and filling with grout S2 Details of: (a) ultimate tensile strength and jacking force applied to tendons (b) duct type and size (c) type of grout (d) anchorages (e) type of sheathing (if any)
CLASSIFICATION TABLE 1 Tendons 1 In suspended slabs 2 In beams 1 Jacking force applied, length and reference No M1 Lengths are given as a straight line between outer faces of anchorages with no allowance for undulations along the length of the tendon C1 Work is held to include: (a) ducts and grouting to ducts (b) anchorages including anchor plates, cones, wedges and the like (c) sheathing (d) supports to the material used in the formation of ducts (e) forming and grouting of air holes (f) degreasing, straightening, cutting to lengths and assembling tendons and cutting off ends after tensioning (g) formwork to form recesses for anchorages and filling with grout
03231/1
03231/2
S2 Details of drawings and other design information required
S2 Details of (a) fillers and sealants (b) waterstops (b) dowel bars (where measured as part of the joint)
item
03250/1
03300/1
CLASSIFICATION TABLE 1 Blinding beds 1 Thickness stated m 1 Sloping < 15 2 Sloping > 15 3 Vertical 2 Wall footings and the like 3 Column bases, isolated footings, pedestals and the like 4 Pile caps 5 Ground beams 6 Mat foundations 7 Columns 8 Casings to structural steel columns 9 Walls 10 Retaining walls 11 Parapet walls and planter walls 12 Slab on grade, beds and the like 13 Suspended slabs 14 Waffle slabs 15 Troughed slabs 16 Machine bases and plinths 3 Casting against faces of excavations 1 Sloping < 15 2 Sloping > 15 M9 The measurement of suspended slabs are taken across attached beams except where beams are of a different mix M10 Waffle and troughed slabs include margins whose width is < 500mm. Wider margins are included with suspended slabs M11 Cantilevered planter boxes are measured in item 03300.23 1 Thickness stated m 1 Casting against faces of excavations m M7 If the width of a column is >four times its thickness it is classified as a wall M8 Walls are measured between columns D2 The stated thickness is that of the general area and excludes thickenings, projections and recesses D3 The stated thickness of waffle and troughed slabs is the overall thickness D4 Suspended slabs include: (a) ramp slabs (b) landings at floor level (c) attached drop panels m 1 Casting against faces of excavations M6 Wall footings are measured between attached column bases D1 Ground beams include tie beams and the like
C2 Reinforced concrete is held to include for vibration C3 Blinding beds are held to include: (a) formwork (b) casting against face of excavations
03300/2
03300/3
20 Staircases
C5 Staircases include steps, support beams, strings, intermediate landings and aprons 1 Permanent mesh to form shoulders D5 Shoulders to beams and slabs are only measured where designed by the Structural Engineer C6 Additional formwork to form shoulders is held to be included
22 Curbs, upstands, zocalos and the like 23 Sunbreakers, fins, hoods, fascias, cantilevered planter boxes and the like 24 Copings 25 Corbels 26 Balustrades 27 Counters, shelves and the like 28 Louvers
03400/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of fixing S3 Surface finishes S4 Reinforcement details S5 Details of any castin accessories S6 Pretensioning materials and stresses
1 Special fittings
1 Dimensioned description
No m
1 Curved
D1 Special fittings are ends, angles and intersections which differ from the general design
CLASSIFICATION TABLE 1 Surface finishes to unset concrete 1 Power floating 2 Trowelling 3 Wood floating 4 Broom finishing 2 Surface finishes to set concrete 1 Rubbed finish 2 Hacking 3 Grinding 4 Sandblasting
1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved 3 Surface treatment, details stated
03345/1
03420/1
03500/1
SUPPLEMENTARY INFORMATION S1 Kind, quality, composition and mix of materials including waterproofing agents and other admixtures S2 Fabric or other reinforcement required S3 Number of coats S4 Method of application S5 Nature of base S6 Surface finish or materials to be received
CLASSIFICATION TABLE
1 Thickness
C2 Floors and roofs are held to include for laying to falls, currents and slopes < 15
4 Worktops, vanity tops, seats and the like 5 Watertank sides and bases 6 Skirtings 7 Treads 8 Risers 9 Strings 10 Splashbacks 11 Fascias 12 Linings to channels 13 Coverings to curbs 14 Cappings 15 Angle fillets
1 Thickness
1 Dimensioned description
C3 Linings to channels and coverings to curbs are held to include additional work to ends
D3 (Isolated) Angle fillets are those not associated with cementitious decks and toppings. Those associated with toppings are held to be included by C1 (m)
03500/2
04200/1
CLASSIFICATION TABLE
1 Built fair and pointed one side 2 Built fair and pointed both sides
D1 Walls are held to be vertical and of constant thickness unless otherwise described
C2 Concrete hollow block walls are held to include for: (a) reinforcement including dowel bars and starter bars (b) filling cavities with mortar (c) cast in place concrete stiffeners and lintel beams including formwork and reinforcement and precast concrete hollow beam blocks forming lintel beams (lintels over openings are measured separately. See 04200.10) C3 Concrete hollow block walls and solid concrete block walls are held to include: (a) blocks of special shape and size at ends, angles or as otherwise required (b) concrete infilling around inserts and protrusions or as otherwise necessary
S2 Composition and mix of mortar S3 Type of pointing where built fair S4 For concrete hollow block walls, details of: (a) reinforcement (b) concrete stiffeners
5 Projections
1 Size stated
1 Vertical 2 Horizontal
6 Bonding to existing
C4 Work is held to include for all labor and materials in bonding new walls to existing
S5 Method of bonding
04200/2
04200/3
9 Designed joints
1 Dimensioned description
1 Sealants 2 Curved
M5 Joints are only measured where designed by the Structural Engineer M6 Cast in place lintels are given as composite items and described giving the information in the following sections as necessary: (a) Section 03100 Concrete Formwork (b) Section 03200 Concrete Reinforcement (c) Section 03300 - Cast in Place Concrete (d) Section 03345 Concrete Finishing M7 Precast concrete lintels are measured in accordance with Section 03400 - Precast Concrete D2 Lintels are isolated lintels over openings. Lintel beams in concrete hollow block walls are held to be included with the walls. See 04200.C2
C6 Joints not designed by the Structural Engineer are held to be included C7 Cast in place lintels are held to include: (a) reinforcement (b) formwork C8 Concrete hollow beam blocks forming lintels are held to include: (a) reinforcement including dowel bars and starter bars (b) filling cavities with mortar (c) blocks of special shape and size at ends, angles or as otherwise required (d) temporary support
10 Lintels
1 Cast in place
1 Dimensioned description
2 Precast concrete
1 Dimensioned description
1 Dimensioned description
CLASSIFICATION TABLE 1 Columns 2 Beams 3 Purlins 4 Rails 5 Bracing 6 Members of roof trusses, reference and number stated 7 Members of portal frames, reference and number stated 1 Cross sectional shape and dimensions 1 Weight per meter kg 1 Curved 2 Cambered 3 Tapered 4 Cranked 5 Castellated M2 The mass of members is measured from their overall lengths with no deductions for splay cuts or mitered ends or for the mass of metal removed to form notches, holes and perforations M3 No allowance is made for rolling margins or for the mass of weld fillets, ordinary bolts, nuts, washers, rivets and protective coatings M4 The mass of steel is taken for measurement as 7850 Kg/m3
05100/1
05100/2
1 Details stated
No
C3 Work is held to include: (a) all labors in fabricating and fixing (b) nuts, washers and all other accessories (c) drilling or cutting holes in any material (d) casting in or building in
13 Permanent formwork
1 Curved
1 Column bases
1 Size stated
No
1 Concrete
1 Size stated
CLASSIFICATION TABLE 1 Columns 2 Beams 3 Purlins 4 Rails 5 Bracing 6 Members of roof trusses, reference and number stated 7 Members of portal frames, reference and number stated 1 Cross sectional shape and dimensions 1 Weight per meter kg 1 Curved 2 Cambered 3 Tapered 4 Cranked 5 Castellated M2 The mass of members is measured from their overall lengths with no deductions for splay cuts or mitered ends or for the mass of metal removed to form notches, holes and perforations M3 No allowance is made for rolling margins or for the mass of weld fillets, ordinary bolts, nuts, washers, rivets and protective coatings M4 The mass of steel is taken for measurement as 7850 Kg/m3
05100/1
05100/2
1 Details stated
No
C3 Work is held to include: (a) all labors in fabricating and fixing (b) nuts, washers and all other accessories (c) drilling or cutting holes in any material (d) casting in or building in
13 Permanent formwork
1 Curved
1 Column bases
1 Size stated
No
1 Concrete
1 Size stated
CLASSIFICATION TABLE 1 Staircases 2 Ladders 3 Walkways 1 Dimensioned description No M2 Work made up of structural steel members is measured in Section 05100 - Structural Steelwork M3 Balustrades and handrails are measured separately, unless noted otherwise in descriptions
05500/1
05500 Metal Fabrications (continued) 05700 Ornamental Metal (continued) 06600 Plastic Fabrications (continued)
4 Balustrades 5 Railings 1 Horizontal 2 Sloping m 1 Curved, radii stated C3 Ends, angles, bends and all other changes in direction are held to be included C4 Balustrades and railings include associated handrails unless noted otherwise in descriptions No D1 Special features are ornamental ends, ornamental angles and other similar features which differ substantially from the general design M4 Handrail brackets are only measured separately here where to timber isolated handrails. Timber isolated handrails are measured in Section 06400 - Architectural Woodwork 1 Hardware 2 Glazing beads 3 Glazing M5 Work contained in the fourth column of the classification table are only included if supplied with the component. Otherwise they are measured separately C5 Fixtures and fittings are held to include all ancillary trims, supports, components and the like
05500/2
6 Isolated handrails
1 Brackets
7 Extra over balustrades for 8 Extra over railings for 9 Extra over isolated handrails for 10 Handrail brackets
1 Dimensioned description
No
1 Dimensioned description
No
12 Grilles 13 Gratings 14 Expansion joint covers 15 Column guards 16 Baseboards 17 Window boards
No m
1 Hardware
C6 Ends, angles, bends and all other changes in direction are held to be included
06100/1
06100/2
CLASSIFICATION TABLE 1 Structural members 1 Floor members 2 Wall or partition members 3 Members of roof trusses, reference and number stated 4 Pitched roof members 5 Flat roof members 6 Plates 7 Bridging 1 Cross sectional size m 1 Curved, radii stated M1 Bridging is measured over joists D2 Floor members and flat roof members include joists and beams D3 Members of roof trusses include top and bottom chords, collar plates, kingposts, web members and wood connectors D4 Pitched roof members include struts, purlins, rafters, hip and valley rafters, ridges, ceiling joists, binders, cleats and bracing D5 Plates are those to structural elements only and include bearers and girts 2 Individual supports 1 Grounds 2 Battens 3 Bearers 4 Packings 5 Fillets 6 Upstands and curbs 7 Ceiling joist hangers 1 Cross sectional size m 1 Curved, radii stated C2 Work is held to include gusset plates and the like
1 To floors 2 To walls and columns 3 To ceilings and beams 4 To soffits of staircases and landings
m m
1 To fascias 2 To eaves soffits 3 To vertical pipe casings and false columns 4 To horizontal pipe casings and false beams 5 To steel columns 6 To steel beams 7 To suspended ceilings 8 To bulkheads in suspended ceilings 9 To light coves
m m
C3 Work is held to include: (a) additional members at ends, angles, intersections, abutments and for trimming around openings, projections and into recesses (b) additional members for fixing partitions, suspended ceilings, fixtures, fittings and for all other fixings as otherwise required (c) fixing to any type of base at abutments
1 Dimensioned description
1 Dimensioned description
No
C4 Work is held to include: (a) all labors in fabricating and fixing (b) nuts, washers and all other accessories (c) drilling or cutting holes in any material (d) casting in or building in
06100/3
06160/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 For solid timber if rough or dressed and if kiln dried S3 Method of jointing or form of construction S4 Method of fixing S5 Nature of base, where other than timber S6 Preservatives treatments applied as part of the production process S7 Surface treatments applied as part of the production process S8 Size of boards and thickness of sheets
CLASSIFICATION TABLE
(o) provision for wood preservatives treatment (p) sundry items of a like nature
1 Floors 2 Walls and columns 3 Roofs 4 Fascias 5 Eaves soffits 6 Vertical pipe casings, false columns and casings to steel columns 7 Horizontal pipe casings, false beams and casings to steel beams 8 Ceilings and beams 9 Soffits of staircases and landings 10 Soffits of spiral staircases 11 Soffits of helical ramps
1 Dimensioned description
M2 No deduction is made for voids < 1.00m M3 Fascias and eaves soffits made up of solid wood, other than boarding, are measured in Section 06200 - Finish Carpentry
D2 Floors include to floors within roof spaces and to landings D3 Walls and columns include: (a) edges of openings and recesses in walls and columns (b) attached pipe casings, false columns and casings to steel columns where they are the same in nature D4 Ceilings and beams include: (a) edges of openings and recesses in ceilings and beams (b) bulkheads and light coves (c) attached pipe casings, false beams and casings to steel beams where they are the same in nature D5 Beams attached to ceilings are classified as the same height to soffit as the ceiling, where they are the same in nature
C2 Floors and roofs are held to include laying to falls, currents and slopes
1 Dimensioned description
1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved, radii stated 3 Patterned, details stated
1 Dimensioned description
1 Width stated
1 Access panels
1 Dimensioned description
No
06160/2
06200/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 For solid timber if rough or dressed and if kiln dried S3 Method of jointing or form of construction S4 Method of fixing S5 Nature of base, where other than timber S6 Preservatives treatments applied as part of the production process S7 Surface treatments applied as part of the production process
CLASSIFICATION TABLE 1 Baseboards 2 Dado rails, mouldings and the like to walls 3 Cornices 4 Mouldings and the like to ceilings 5 Trims, cover fillets and the like 6 Beads 7 Nosings 8 Cappings 9 Window sills 10 Window boards 11 Window casings 12 Fascias 13 Eaves soffits 14 Isolated Shelves and worktops 15 Duct covers 16 Treads 17 Risers 1 Cross sectional size and shape m 1 Curved, radii stated 2 Built up members, size of components stated M2 Fascias and eaves soffits made up of wood sheet or wood boarding are measured in Section 06160 - Sheet and Board Linings and Panelling
1 Dimensioned description
No
06200/2
06400/1
CLASSIFICATION TABLE 1 Staircases 1 Dimensioned description No 1 Associated balustrades and handrails M1 Balustrades and handrails are measured separately, unless noted otherwise in descriptions
C2 Staircases are held to include: (a) linings, nosings, cover moulds, trims and the like where part of the component (b) soffit lining, spandrel panels and the like where part of the component (c) ancillary supports, components, blockings, wedges and the like C3 Ends, angles, bends and all other changes in direction are held to be included C4 Balustrades include associated handrails unless noted otherwise in descriptions D2 Special features are newel posts, ornamental ends, ornamental angles and other similar features which differ substantially from the general design
1 Horizontal 2 Sloping
M2 Metal brackets to isolated handrails are measured in one of the following sections as applicable: (a) Section 05500 - Metal Fabrications (b) Section 05700 Ornamental Metal
5 Extra over balustrades for 6 Extra over railings for 7 Extra over isolated handrails for 8 Louvers 9 Sliding/folding partitions 10 Fixtures and fittings
No
1 Dimensioned description
No
1 Hardware
M3 Louvers of any material other than wood are measured in Section 10200 - Louvers and Vents M4 Hardware may be measured separately in Section 08700 Hardware
D3 Fixtures and fittings include cabinets, counters, wardrobes, shelves and the like
C5 Work is held to include all ancillary trims, supports, components and the like
06400/2
07110/1
07110 Sheet Membrane and Felt Waterproofing 07510 Sheet Membrane and Felt Roofing
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured the net area covered with no allowance for laps M2 No deduction is made for voids < 0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) fair joints to all types of work (b) internal angle fillets (c) dressing over tilting fillets (d) fair and rounded edges, angles and drips (e) turning into grooves including additional materials (f) working into recessed duct and manhole covers (g) dishing to outlets and gullies (h) working up to flashings and frames (i) forming or working into channels < 50mm deep (j) working over and around obstructions (k) laps, cutting, notching and bending (l) preparing bases including hacking concrete surfaces to form a key (m) jointing between sections where the nature of the work requires it to be carried out in sections (n) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials including underlays S2 Nature of base S3 Method of application S4 Treatment of joints and minimum laps
CLASSIFICATION TABLE 1 Floors 2 Landings 3 Roofs 4 Walls and columns 5 Watertank sides and bases m 1 Curved D1 Floors include to floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns C2 Floors, landings and roofs are held to include for laying to falls, currents and slopes
D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
8 Turning up at edges 9 Treads 10 Risers 11 Strings 12 Fascias and aprons 13 Linings to gutters 14 Linings to channels 15 Coverings to curbs
1 Dimensioned description
1 Curved
M3 Linings to channels are only measured where > 50mm deep M4 Turning up at edges > 300mm wide is classified as walls and columns
C3 Linings to gutters and channels and coverings to curbs are held to include additional waterproofing to ends
07110/2
07110 Sheet Membrane and Felt Waterproofing (continued) 07510 Sheet Membrane and Felt Roofing (continued)
16 Linings to cesspools, sumps and the like 17 Collars around pipes, railings, standards and the like 18 Surface applications 1 Solar reflective paint 2 Stone chippings 19 Guarantees 1 Details stated 1 Duration stated item m 1 Dimensioned description No
07110/3
07120 Asphalt and Fluid Applied Waterproofing 07540 Asphalt and Fluid Applied Roofing
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured that in contact with the base and no deduction is made for voids < 0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) fair joints to all types of work (b) internal angle fillets (c) dressing over tilting fillets (d) fair and rounded edges, angles and drips (e) turning into grooves including additional materials (f) working into recessed duct and manhole covers (g) dishing to outlets and gullies (h) working up to flashings and frames (i) forming or working into channels < 50mm deep (j) working over and around obstructions (k) laps, cutting, notching and bending of underlay and reinforcement (l) preparing bases including hacking concrete surfaces to form a key (m) rubbing surfaces with a wood float with clean sand if required (n) jointing between sections where the nature of the work requires it to be carried out in sections (p) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials, including underlays and reinforcement. S2 Nature of base S3 Number of coats S4 Method of application S5 Surface treatments
07120/1
07120 Asphalt and Fluid Waterproofing (continued) 07540 Asphalt and Fluid Applied Roofing (continued)
07120/2
CLASSIFICATION TABLE 1 Floors 2 Landings 3 Roofs 4 Walls and columns 5 Watertank sides and bases 1 Thickness m 1 Floors, landings or roofs sloping >15 2 Curved D1 Floors include to floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns C2 Floors, landings and roofs are held to include for laying to falls, currents and slopes < 15
1 Thickness
D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
8 Turning up at edges 9 Treads 10 Risers 11 Strings 12 Fascias and aprons 13 Linings to gutters 14 Linings to channels 15 Coverings to curbs
1 Dimensioned description
1 Curved
M2 Linings to channels are only measured where > 50mm deep M3 Turning up at edges > 300mm wide is classified as walls and columns
C3 Linings to gutters and channels and coverings to curbs are held to include additional waterproofing to ends
16 Linings to cesspools, sumps and the like 17 Collars around pipes, railings, standards and the like 18 Surface applications
1 Dimensioned description
No
19 Guarantees
1 Details stated
1 Duration stated
item
07120/3
07190/1
2 Guarantees
1 Details stated
1 Duration stated
item
07200 Insulation
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured the net area covered with no allowance for laps M2 No deduction is made for voids <0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) all jointing materials (b) all fixing materials including bedding mortars, adhesives and mechanical fixings (c) all cutting and fitting over and around obstructions (d) cutting holes (e) preparing bases (f) extra material for laps (g) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of fixing S3 Nature of base S4 Treatment of joints S5 Extent of laps
CLASSIFICATION TABLE 1 Floors 2 Roofs 3 Walls and columns 1 Thickness m 1 Across members, centers of members stated 2 Between members, centers of members stated 3 Curved 4 Ceilings and beams 5 Soffits of staircases and landings 1 Thickness m 1 Across members, centers of members stated 2 Between members, centers of members stated 3 Height to soffit >3.50m above floor in stages of 1.50m 4 Curved D1 Floors include floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature C2 Floors and roofs are held to include laying to falls, currents and slopes
07200/1
07300/1
SUPPLEMENTARY INFORMATION S1 Kind, quality and size of materials S2 Method of fixing S3 Nature of base S4 Minimum laps
CLASSIFICATION TABLE 1 Roof coverings 2 Wall coverings 1 Pitch stated 1 Battens m 1 Counter battens 2 Underlay 3 Curved, radii stated C2 Coverings are held to include: (a) work in forming voids and holes <0.50m (b) cutting, fitting and making good around outlets, pipes and the like (c) additional battens at ends, angles and the like M3 Work to perimeter of voids is only measured where the void is > 0.50 m C3 Work is held to include: (a) undercloaks (b) tiles and shingles of special size and shape to suit the location (c) bedding and pointing (d) ends, angles and intersections including special shaped tiles and shingles as necessary D1 Special fittings include ventilators, finials and the like S5 Spacing of battens and counter battens
1 Dimensioned description
1 Dimensioned description
No m
10 Guarantees
1 Details stated
1 Duration stated
item
CLASSIFICATION TABLE 1 Roof coverings 2 Wall coverings 1 Pitch stated m 1 Underlay 2 Curved, radii stated C2 Coverings are held to include: (a) work in forming voids and holes <0.50m (b) cutting, fitting and making good around outlets, pipes and the like M3 Work to perimeter of voids is only measured where the void is > 0.50 m C3 Work is held to include: (a) sheets of special size and shape to suit the location (b) ends, angles and intersections including special shaped flashings, cappings, junction pieces and the like as necessary S5 Spacing of structural supports, where applicable
3 Ridges 4 Hips 5 Valleys 6 Eaves 7 Gables 8 Abutments 9 Flashings 10 Gutters 11 Filler pieces
1 Dimensioned description
07400/1
07400/2
13 Guarantees
1 Details stated
1 Duration stated
item
07900 Sealants
INFORMATION TO BE PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION
CLASSIFICATION TABLE 1 Joints 2 Pointing 1 Dimensioned description m 1 Backing rods C1 Work is held to include preparation, cleaners, primers and sealers appropriate to the base S1 Kind and quality of materials S2 Method of application S3 Nature of base
07900/1
08100 Metal Doors and Frames 08220 Plastic Doors and Frames
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 The following are measured in other sections unless noted otherwise: (a) pointing around frames and the like with sealant in Section 07900 - Sealants (b) glazing in Section 08800 - Glazing DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) bolts, screws, brackets, ties and all other fixings, fastenings and supports including drilling or cutting holes in any material (b) drilling and plugging concrete, masonry and the like with hardwood or proprietary plugs for fixing with screws (c) notching and holes (d) bedding in mortar (e) filling behind frames with concrete/mortar including all necessary formwork (f) finishes where part of the components as delivered (g) all necessary incidental work for the proper execution of the item (h) sundry items of a like nature
08100/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of jointing or form of construction S3 Method of fixing S4 Nature of base S5 Surface treatments and finishes applied before delivery
CLASSIFICATION TABLE 1 Doors and frames 2 Doors 3 Door frames 4 Roller shutters and frames 5 Access hatches and frames 1 Dimensioned description No 1 Glazing beads 2 Trims 3 Weatherstripping
08210/1
08210/2
5 Architraves
1 Dimensioned description
CLASSIFICATION TABLE 1 Entrance screens 2 Shopfronts 3 Frameless glass doors 4 Frameless glass windows 1 Dimensioned description 1 Type and thickness of glass No 1 Hardware 2 Glazing beads 3 Trims 4 Weatherstripping
08400/1
CLASSIFICATION TABLE 1 Staircases 2 Ladders 3 Walkways 1 Dimensioned description No M2 Work made up of structural steel members is measured in Section 05100 - Structural Steelwork M3 Balustrades and handrails are measured separately, unless noted otherwise in descriptions
05500/1
05500 Metal Fabrications (continued) 05700 Ornamental Metal (continued) 06600 Plastic Fabrications (continued)
4 Balustrades 5 Railings 1 Horizontal 2 Sloping m 1 Curved, radii stated C3 Ends, angles, bends and all other changes in direction are held to be included C4 Balustrades and railings include associated handrails unless noted otherwise in descriptions No D1 Special features are ornamental ends, ornamental angles and other similar features which differ substantially from the general design M4 Handrail brackets are only measured separately here where to timber isolated handrails. Timber isolated handrails are measured in Section 06400 - Architectural Woodwork 1 Hardware 2 Glazing beads 3 Glazing M5 Work contained in the fourth column of the classification table are only included if supplied with the component. Otherwise they are measured separately C5 Fixtures and fittings are held to include all ancillary trims, supports, components and the like
05500/2
6 Isolated handrails
1 Brackets
7 Extra over balustrades for 8 Extra over railings for 9 Extra over isolated handrails for 10 Handrail brackets
1 Dimensioned description
No
1 Dimensioned description
No
12 Grilles 13 Gratings 14 Expansion joint covers 15 Column guards 16 Baseboards 17 Window boards
No m
1 Hardware
C6 Ends, angles, bends and all other changes in direction are held to be included
06100/1
06100/2
CLASSIFICATION TABLE 1 Structural members 1 Floor members 2 Wall or partition members 3 Members of roof trusses, reference and number stated 4 Pitched roof members 5 Flat roof members 6 Plates 7 Bridging 1 Cross sectional size m 1 Curved, radii stated M1 Bridging is measured over joists D2 Floor members and flat roof members include joists and beams D3 Members of roof trusses include top and bottom chords, collar plates, kingposts, web members and wood connectors D4 Pitched roof members include struts, purlins, rafters, hip and valley rafters, ridges, ceiling joists, binders, cleats and bracing D5 Plates are those to structural elements only and include bearers and girts 2 Individual supports 1 Grounds 2 Battens 3 Bearers 4 Packings 5 Fillets 6 Upstands and curbs 7 Ceiling joist hangers 1 Cross sectional size m 1 Curved, radii stated C2 Work is held to include gusset plates and the like
1 To floors 2 To walls and columns 3 To ceilings and beams 4 To soffits of staircases and landings
m m
1 To fascias 2 To eaves soffits 3 To vertical pipe casings and false columns 4 To horizontal pipe casings and false beams 5 To steel columns 6 To steel beams 7 To suspended ceilings 8 To bulkheads in suspended ceilings 9 To light coves
m m
C3 Work is held to include: (a) additional members at ends, angles, intersections, abutments and for trimming around openings, projections and into recesses (b) additional members for fixing partitions, suspended ceilings, fixtures, fittings and for all other fixings as otherwise required (c) fixing to any type of base at abutments
1 Dimensioned description
1 Dimensioned description
No
C4 Work is held to include: (a) all labors in fabricating and fixing (b) nuts, washers and all other accessories (c) drilling or cutting holes in any material (d) casting in or building in
06100/3
06160/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 For solid timber if rough or dressed and if kiln dried S3 Method of jointing or form of construction S4 Method of fixing S5 Nature of base, where other than timber S6 Preservatives treatments applied as part of the production process S7 Surface treatments applied as part of the production process S8 Size of boards and thickness of sheets
CLASSIFICATION TABLE
(o) provision for wood preservatives treatment (p) sundry items of a like nature
1 Floors 2 Walls and columns 3 Roofs 4 Fascias 5 Eaves soffits 6 Vertical pipe casings, false columns and casings to steel columns 7 Horizontal pipe casings, false beams and casings to steel beams 8 Ceilings and beams 9 Soffits of staircases and landings 10 Soffits of spiral staircases 11 Soffits of helical ramps
1 Dimensioned description
M2 No deduction is made for voids < 1.00m M3 Fascias and eaves soffits made up of solid wood, other than boarding, are measured in Section 06200 - Finish Carpentry
D2 Floors include to floors within roof spaces and to landings D3 Walls and columns include: (a) edges of openings and recesses in walls and columns (b) attached pipe casings, false columns and casings to steel columns where they are the same in nature D4 Ceilings and beams include: (a) edges of openings and recesses in ceilings and beams (b) bulkheads and light coves (c) attached pipe casings, false beams and casings to steel beams where they are the same in nature D5 Beams attached to ceilings are classified as the same height to soffit as the ceiling, where they are the same in nature
C2 Floors and roofs are held to include laying to falls, currents and slopes
1 Dimensioned description
1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved, radii stated 3 Patterned, details stated
1 Dimensioned description
1 Width stated
1 Access panels
1 Dimensioned description
No
06160/2
06200/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 For solid timber if rough or dressed and if kiln dried S3 Method of jointing or form of construction S4 Method of fixing S5 Nature of base, where other than timber S6 Preservatives treatments applied as part of the production process S7 Surface treatments applied as part of the production process
CLASSIFICATION TABLE 1 Baseboards 2 Dado rails, mouldings and the like to walls 3 Cornices 4 Mouldings and the like to ceilings 5 Trims, cover fillets and the like 6 Beads 7 Nosings 8 Cappings 9 Window sills 10 Window boards 11 Window casings 12 Fascias 13 Eaves soffits 14 Isolated Shelves and worktops 15 Duct covers 16 Treads 17 Risers 1 Cross sectional size and shape m 1 Curved, radii stated 2 Built up members, size of components stated M2 Fascias and eaves soffits made up of wood sheet or wood boarding are measured in Section 06160 - Sheet and Board Linings and Panelling
1 Dimensioned description
No
06200/2
06400/1
CLASSIFICATION TABLE 1 Staircases 1 Dimensioned description No 1 Associated balustrades and handrails M1 Balustrades and handrails are measured separately, unless noted otherwise in descriptions
C2 Staircases are held to include: (a) linings, nosings, cover moulds, trims and the like where part of the component (b) soffit lining, spandrel panels and the like where part of the component (c) ancillary supports, components, blockings, wedges and the like C3 Ends, angles, bends and all other changes in direction are held to be included C4 Balustrades include associated handrails unless noted otherwise in descriptions D2 Special features are newel posts, ornamental ends, ornamental angles and other similar features which differ substantially from the general design
1 Horizontal 2 Sloping
M2 Metal brackets to isolated handrails are measured in one of the following sections as applicable: (a) Section 05500 - Metal Fabrications (b) Section 05700 Ornamental Metal
5 Extra over balustrades for 6 Extra over railings for 7 Extra over isolated handrails for 8 Louvers 9 Sliding/folding partitions 10 Fixtures and fittings
No
1 Dimensioned description
No
1 Hardware
M3 Louvers of any material other than wood are measured in Section 10200 - Louvers and Vents M4 Hardware may be measured separately in Section 08700 Hardware
D3 Fixtures and fittings include cabinets, counters, wardrobes, shelves and the like
C5 Work is held to include all ancillary trims, supports, components and the like
06400/2
07110/1
07110 Sheet Membrane and Felt Waterproofing 07510 Sheet Membrane and Felt Roofing
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured the net area covered with no allowance for laps M2 No deduction is made for voids < 0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) fair joints to all types of work (b) internal angle fillets (c) dressing over tilting fillets (d) fair and rounded edges, angles and drips (e) turning into grooves including additional materials (f) working into recessed duct and manhole covers (g) dishing to outlets and gullies (h) working up to flashings and frames (i) forming or working into channels < 50mm deep (j) working over and around obstructions (k) laps, cutting, notching and bending (l) preparing bases including hacking concrete surfaces to form a key (m) jointing between sections where the nature of the work requires it to be carried out in sections (n) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials including underlays S2 Nature of base S3 Method of application S4 Treatment of joints and minimum laps
CLASSIFICATION TABLE 1 Floors 2 Landings 3 Roofs 4 Walls and columns 5 Watertank sides and bases m 1 Curved D1 Floors include to floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns C2 Floors, landings and roofs are held to include for laying to falls, currents and slopes
D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
8 Turning up at edges 9 Treads 10 Risers 11 Strings 12 Fascias and aprons 13 Linings to gutters 14 Linings to channels 15 Coverings to curbs
1 Dimensioned description
1 Curved
M3 Linings to channels are only measured where > 50mm deep M4 Turning up at edges > 300mm wide is classified as walls and columns
C3 Linings to gutters and channels and coverings to curbs are held to include additional waterproofing to ends
07110/2
07110 Sheet Membrane and Felt Waterproofing (continued) 07510 Sheet Membrane and Felt Roofing (continued)
16 Linings to cesspools, sumps and the like 17 Collars around pipes, railings, standards and the like 18 Surface applications 1 Solar reflective paint 2 Stone chippings 19 Guarantees 1 Details stated 1 Duration stated item m 1 Dimensioned description No
07110/3
07120 Asphalt and Fluid Applied Waterproofing 07540 Asphalt and Fluid Applied Roofing
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured that in contact with the base and no deduction is made for voids < 0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) fair joints to all types of work (b) internal angle fillets (c) dressing over tilting fillets (d) fair and rounded edges, angles and drips (e) turning into grooves including additional materials (f) working into recessed duct and manhole covers (g) dishing to outlets and gullies (h) working up to flashings and frames (i) forming or working into channels < 50mm deep (j) working over and around obstructions (k) laps, cutting, notching and bending of underlay and reinforcement (l) preparing bases including hacking concrete surfaces to form a key (m) rubbing surfaces with a wood float with clean sand if required (n) jointing between sections where the nature of the work requires it to be carried out in sections (p) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials, including underlays and reinforcement. S2 Nature of base S3 Number of coats S4 Method of application S5 Surface treatments
07120/1
07120 Asphalt and Fluid Waterproofing (continued) 07540 Asphalt and Fluid Applied Roofing (continued)
07120/2
CLASSIFICATION TABLE 1 Floors 2 Landings 3 Roofs 4 Walls and columns 5 Watertank sides and bases 1 Thickness m 1 Floors, landings or roofs sloping >15 2 Curved D1 Floors include to floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns C2 Floors, landings and roofs are held to include for laying to falls, currents and slopes < 15
1 Thickness
D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
8 Turning up at edges 9 Treads 10 Risers 11 Strings 12 Fascias and aprons 13 Linings to gutters 14 Linings to channels 15 Coverings to curbs
1 Dimensioned description
1 Curved
M2 Linings to channels are only measured where > 50mm deep M3 Turning up at edges > 300mm wide is classified as walls and columns
C3 Linings to gutters and channels and coverings to curbs are held to include additional waterproofing to ends
16 Linings to cesspools, sumps and the like 17 Collars around pipes, railings, standards and the like 18 Surface applications
1 Dimensioned description
No
19 Guarantees
1 Details stated
1 Duration stated
item
07120/3
07190/1
2 Guarantees
1 Details stated
1 Duration stated
item
07200 Insulation
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 Work is measured the net area covered with no allowance for laps M2 No deduction is made for voids <0.50m DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) all jointing materials (b) all fixing materials including bedding mortars, adhesives and mechanical fixings (c) all cutting and fitting over and around obstructions (d) cutting holes (e) preparing bases (f) extra material for laps (g) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of fixing S3 Nature of base S4 Treatment of joints S5 Extent of laps
CLASSIFICATION TABLE 1 Floors 2 Roofs 3 Walls and columns 1 Thickness m 1 Across members, centers of members stated 2 Between members, centers of members stated 3 Curved 4 Ceilings and beams 5 Soffits of staircases and landings 1 Thickness m 1 Across members, centers of members stated 2 Between members, centers of members stated 3 Height to soffit >3.50m above floor in stages of 1.50m 4 Curved D1 Floors include floors within roof spaces D2 Walls and columns include edges of openings, recesses and projections on walls and columns D3 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D4 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature C2 Floors and roofs are held to include laying to falls, currents and slopes
07200/1
07300/1
SUPPLEMENTARY INFORMATION S1 Kind, quality and size of materials S2 Method of fixing S3 Nature of base S4 Minimum laps
CLASSIFICATION TABLE 1 Roof coverings 2 Wall coverings 1 Pitch stated 1 Battens m 1 Counter battens 2 Underlay 3 Curved, radii stated C2 Coverings are held to include: (a) work in forming voids and holes <0.50m (b) cutting, fitting and making good around outlets, pipes and the like (c) additional battens at ends, angles and the like M3 Work to perimeter of voids is only measured where the void is > 0.50 m C3 Work is held to include: (a) undercloaks (b) tiles and shingles of special size and shape to suit the location (c) bedding and pointing (d) ends, angles and intersections including special shaped tiles and shingles as necessary D1 Special fittings include ventilators, finials and the like S5 Spacing of battens and counter battens
1 Dimensioned description
1 Dimensioned description
No m
10 Guarantees
1 Details stated
1 Duration stated
item
CLASSIFICATION TABLE 1 Roof coverings 2 Wall coverings 1 Pitch stated m 1 Underlay 2 Curved, radii stated C2 Coverings are held to include: (a) work in forming voids and holes <0.50m (b) cutting, fitting and making good around outlets, pipes and the like M3 Work to perimeter of voids is only measured where the void is > 0.50 m C3 Work is held to include: (a) sheets of special size and shape to suit the location (b) ends, angles and intersections including special shaped flashings, cappings, junction pieces and the like as necessary S5 Spacing of structural supports, where applicable
3 Ridges 4 Hips 5 Valleys 6 Eaves 7 Gables 8 Abutments 9 Flashings 10 Gutters 11 Filler pieces
1 Dimensioned description
07400/1
07400/2
13 Guarantees
1 Details stated
1 Duration stated
item
07900 Sealants
INFORMATION TO BE PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION
CLASSIFICATION TABLE 1 Joints 2 Pointing 1 Dimensioned description m 1 Backing rods C1 Work is held to include preparation, cleaners, primers and sealers appropriate to the base S1 Kind and quality of materials S2 Method of application S3 Nature of base
07900/1
08100 Metal Doors and Frames 08220 Plastic Doors and Frames
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 The following are measured in other sections unless noted otherwise: (a) pointing around frames and the like with sealant in Section 07900 - Sealants (b) glazing in Section 08800 - Glazing DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) bolts, screws, brackets, ties and all other fixings, fastenings and supports including drilling or cutting holes in any material (b) drilling and plugging concrete, masonry and the like with hardwood or proprietary plugs for fixing with screws (c) notching and holes (d) bedding in mortar (e) filling behind frames with concrete/mortar including all necessary formwork (f) finishes where part of the components as delivered (g) all necessary incidental work for the proper execution of the item (h) sundry items of a like nature
08100/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of jointing or form of construction S3 Method of fixing S4 Nature of base S5 Surface treatments and finishes applied before delivery
CLASSIFICATION TABLE 1 Doors and frames 2 Doors 3 Door frames 4 Roller shutters and frames 5 Access hatches and frames 1 Dimensioned description No 1 Glazing beads 2 Trims 3 Weatherstripping
08210/1
08210/2
5 Architraves
1 Dimensioned description
CLASSIFICATION TABLE 1 Entrance screens 2 Shopfronts 3 Frameless glass doors 4 Frameless glass windows 1 Dimensioned description 1 Type and thickness of glass No 1 Hardware 2 Glazing beads 3 Trims 4 Weatherstripping
08400/1
08500/1
08500 Metal Windows, Rooflights and Screens 08630 Plastic Windows, Rooflights and Screens
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 The following are measured in other sections unless noted otherwise: (a) pointing around frames and the like with sealant in Section 07900 - Sealants (b) glazing in Section 08800 - Glazing DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) bolts, screws, brackets, ties and all other fixings, fastenings and supports including drilling or cutting holes in any material (b) drilling and plugging concrete, masonry and the like with hardwood or proprietary plugs for fixing with screws (c) notching and holes (d) bedding in mortar (e) filling behind frames with concrete/mortar including all necessary formwork (f) finishes where part of the components as delivered (g) all necessary incidental work for the proper execution of the item (h) sundry items of a like nature SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of jointing or form of construction S3 Method of fixing S4 Nature of base S5 Surface treatments and finishes applied before delivery
CLASSIFICATION TABLE 1 Windows 2 Window shutters 3 Rooflights, skylights and roof windows 4 Screens 5 Glazing 1 Dimensioned description No 1 Hardware 2 Glazing beads 3 Trims 4 Weatherstripping M2 Work contained in the fourth column of the classification table are only included if supplied with the component. Otherwise they are measured separately
08500/2
08610/1
08610/2
CLASSIFICATION TABLE 1 Windows 2 Window shutters 3 Rooflights, skylights and roof windows 4 Screeens 1 Dimensioned description No 1 Glazing beads 2 Architraves 3 Weatherstripping
08700 Hardware
INFORMATION TO BE PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES C1 Work is held to include: (a) providing screws, bolts, nails, pins and all other fixings as necessary to match the hardware (b) all fitting, cutting, sinking, boring and morticing to any backgrounds and making good (c) plugging concrete, masonry and the like (d) oiling, easing and adjusting and leaving in working order at completion CLASSIFICATION TABLE 1 Type of item, unit or set stated 1 Nature of base stated No D1 The nature of base is the material of the main component to which it is fixed C2 Work is held to include fixing to any other backgrounds as necessary, even though the material of the main component is the only one stated SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Surface finish
08700/1
08800 Glazing
INFORMATION TO BE PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES C1 Glazing is held to include: (a) removing and refixing glazing beads (b) raking and curved cutting and cutting notches and the like but excluding holes (c) provision of glazing compound, sealants, gaskets, bedding strips, nails, pins, clips and all other ancillary glazing materials but excluding glazing beads CLASSIFICATION TABLE 1 Glass 1 Thickness stated 1 Panes < 0.10m 2 Panes 0.10 - 0.50m 3 Panes 0.50 - 1.00m 4 Panes thereafter in 1.00m stages 2 Decorative finish, described 3 Ground edges 4 Polished edges 5 Sandblasted edges M2 Glass with a decorative finish is measured here where it is a regular finish across the whole of the pane D2 Decorative patterns to glass which are not regular across the whole pane are measured as extra over the glass in item 08800.7.2 m 1 Irregular shaped panes M1 Panes of irregular shape are classified and measured according to the smallest rectangular area from which the pane can be obtained D1 The following glass is enumerated in items 08800.2-4 below: (a) bent or curved (b) glass with bevelled edges
08800/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Method of glazing including details of glazing compound, sealants, gaskets, bedding strips and the like S3 Nature of frame or surround
2 Bent glass 3 Curved glass 4 Glass with bevelled edges 5 Louvers 6 Shelves
1 Thickness stated
No
1 Curved 2 Bent 3 Ground edges 4 Polished edges 5 Sandblasted edges 6 Bevelled edges
1 Size
No No M3 Decorative patterns to glass are measured here where they are not a regular pattern across the whole of the pane 1 Beads for re-use, details stated M4 Hacking out existing glass and preparing rebates is measured the perimeter of the pane
1 Type of surround and method of glazing stated together with type of glass
08800/2
08900/1
CLASSIFICATION TABLE 1 Curtain walling 2 Contractor designed curtain walling 1 Dimensioned description m 1 Sloping 2 Curved, radii stated 3 Flat panes set to curve 3 Extra over for 1 Spandrel panels 1 Dimensioned description m 1 Sloping 2 Curved, radii stated 3 Flat panels set to curve 2 Closers around door and window openings 3 Closers at floors 4 Window boards 5 Opening lights 6 Doors No 1 Hardware m 1 Curved, radii stated M3 Window boards are only measured in this section where part of the curtain walling system M2 Curtain walling is described as Contractor designed where the design is not completed by the Owner and is left to be completed by the Contractor C2 Work is held to include: (a) all necessary additional work at ends, angles, intersections, abutments and the like (b) bolts, screws, brackets, ties and all other fixings, fastenings and supports including drilling or cutting holes in any material and casting into concrete (c) trimming around projections (d) holes (e) bedding in mortar (f) sealants and pointing (g) finishes where part of the components as delivered C3 Opening lights and doors are held to include: (a) glazing beads (b) architraves and trims (c) frames (d) weatherstripping S1 Kind and quality of materials S2 Method of jointing or form of construction S3 Method of fixing S4 Nature of base S5 Bedding, jointing and pointing compounds S6 Surface treatments and finishes applied before delivery
1 Details given
item
C4 Design information is held to include: (a) completing all aspects of the design not completed by the Owner (b) design drawings (c) working drawings (d) structural calculations (e) all other information necessary to evaluate the Contractor's design (f) presentation of design information to the Project Manager and Structural Engineer and incorporating any design revisions as requested
5 Tests
1 Details stated
item
6 Guarantees
1 Details stated
1 Duration stated
item
08900/2
09100/1
CLASSIFICATION TABLE 1 Suspended ceilings 1 Dimensioned description 1 Depth of suspension <300mm 2 and thereafter in 300mm stages m 1 Height to soffit >3.50m above floor in stages of 1.50m 2 Integral fittings, details stated 3 Curved, radii stated 4 Patterned, details stated 5 External M1 The following are measured in other sections: (a) metal lathing suspended ceilings (Section 09205 - Metal Lathing) (b) linings to ceilings on timber battens or timber suspended framework (timber framework is measured in Section 06100 - Rough Carpentry and gypsum board lining is measured in Section 09250 - Gypsum Board ) M2 No deduction is made for voids < 0.50m M3 Integral fittings are included with the ceiling where part of the suspended ceiling system and they also follow a regular layout. Where fittings are not part of the suspended ceiling system or do not follow a regular layout they are measured separately in accordance with 09100.4.*.*.* D1 Work is held to be internal unless described as external D2 Integral fittings include special panels, diffusers, grilles and the like C1 Work is held to include: (a) all jointing materials (b) suspension and framing members including fixings, trims and the like (c) all cutting and fitting over and around obstructions including cutting and fitting up to frames and around pipes, brackets and the like (d) cutting holes (e) preparing bases (f) additional supports and all other work to provide space for services in the suspended ceiling void (g) additional supports, trims and accessories as necessary to fittings, partitions, access panels, diffusers, grilles, light fittings, fixtures, signs and the like (h) sundry items of a like nature S2 Size and thickness of panels S3 Thickness of sheet linings S4 Details of framing and suspension system S5 Method of fixing S6 Nature of base S7 Treatment of joints and surface finish or materials to be received for sheet linings
1 Dimensioned description
1 Integral fittings, details stated 2 Curved, radii stated 3 Patterned, details stated 4 External
1 Dimensioned description
No
1 External
5 Framework to metal stud partitions 6 Metal framework surface fixed to walls and columns 7 Metal framework surface fixed to ceilings and beams 8 Metal framework surface fixed to soffits of staircases and landings
1 Spacing
M4 No deduction is made for voids < 1.00m M5 The following are measured in other sections: (a) insulation (Section 07200 - Insulation) (b) vapor barriers (Section 07190 - Vapor Retarders) (c) gypsum board (Section 09250 - Gypsum Board) (d) plywood and other timber board linings and panelling (Section 06160 - Sheet and Board Linings and Panelling) (e) sealant pointing (Section 07900 Sealants), unless noted otherwise in descriptions
9 Mesh
C2 Work is held to include: (a) additional members at ends, angles, intersections, abutments and for trimming around openings, projections and into recesses (b) additional members for fixing partitions, suspended ceilings, fixtures, fittings and for all other fixings as otherwise required (c) fixing to concrete, concrete hollow blocks and any other materials by any means including bolting, screwing, ties, cramps and the like (d) all necessary incidental work for the proper execution of the item
09100/2
09205/1
09205/2
intersections (i) all cutting and fitting over and around obstructions including cutting and fitting up to frames and around pipes, brackets and the like (j) cutting holes (k) preparing bases (l) angle and stop beads (m) sundry items of a like nature
CLASSIFICATION TABLE 1 Walls and columns 1 Dimensioned description m 1 Curved 2 External D3 Walls and columns include edges of openings, recesses and projections on walls and columns D4 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D5 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
1 Height to soffit > 3.50m above floor in stages of 1.50m 2 Curved 3 External
4 Cornices 5 Mouldings
1 Dimensioned description
1 Curved 2 External
C2 Work is held to include fair, rounded and coved ends, angles, intersections and sundry items of a like nature M3 Metal lathing suspended ceilings are measured in accordance with Section 09100 Suspended Ceilings and Metal Support Systems
1 Dimensioned description
1 Height to soffit > 3.50m above floor in stages of 1.50m 2 Curved 3 External
2 Bulkheads
1 Dimensioned description
1 Curved 2 External
09205/3
09220/1
CLASSIFICATION TABLE 1 Walls and columns 1 Thickness m 1 Curved 2 Patterned, details stated 3 External 2 Ceilings and beams 3 Soffits of staircases and landings 1 Thickness m 1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved 3 Patterned, details stated 4 External D4 Walls and columns include: (a) edges of openings, recesses and projections on walls and columns (b) tops of walls and columns D5 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D6 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature M2 Measured where it forms part of this finishes. If it forms as backing, it is measured under 03500 Cementitious Decks and Toppings D7 Where skirtings, strings, splashback and fascia forms part of the finish, it will be measured under 09220. If it is a backing to skirting, string, splashback fascia to receive tiles, marbles and wood then it will be measured under 03500 Cementitious Decks and Toppings
1 Dimensioned description
7 Fascias
8 Cornices 9 Mouldings
1 Dimensioned description
09220/2
09250/1
CLASSIFICATION TABLE 1 Walls and columns 1 Thickness m 1 Curved, radii stated 2 External 2 Ceilings and beams 3 Soffits of staircases and landings m 1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved, radii stated 3 External M3 Metal framework to support finishes is measured in Section 09100 - Suspended Ceilings and Metal Support Systems M4 Timber framework to support finishes is measured in Section 06100 - Rough Carpentry D3 Walls and columns include edges of openings, recesses and projections on walls and columns D4 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D5 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature 4 Cornices 5 Mouldings 1 Dimensioned description m 1 Curved, radii stated 2 External
C2 Work is held to include fair, rounded and coved ends, angles, intersections and sundry
09250/2
items of a like nature
09300/1
09300/2
CLASSIFICATION TABLE 1 Floors 2 Landings 2 Curved, radii stated 3 Walls and columns 4 Roofs 5 Worktops, vanity tops, seats and the like 6 Watertank sides and bases 7 Ceilings and beams 8 Soffits of staircases and landings 1 Dimensioned description m 1 Height to soffit >3.50m above floor in stages of 1.50m 2 Curved, radii stated 2 Contrasting bands and margins < 300mm wide, width stated m 3 Flat rigid tiles or slabs set to curve 4 Patterned, details stated 5 External 2 Contrasting bands and margins < 300mm wide, width stated m 3 Flat rigid tiles or slabs set to curve 4 Patterned, details stated 5 External 1 Dimensioned description m 1 Floors or roofs sloping >15 M2 Contrasting bands and margins are only measured separately in meters where < 300mm wide. Where bands and margins are > 300mm wide they are measured as general areas of finishes in square meters M3 Worktops, vanity tops, seats and the like which comprise a single slab of marble, granite or the like are enumerated D4 Floors include to floors within roof spaces D5 Walls and columns include edges of openings, recesses and projections on walls and columns D6 Ceilings and beams include edges of openings, recesses and projections on ceilings and beams D7 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature C4 Floors and roofs are held to include for laying to falls, currents and slopes < 15
9 Skirtings 10 Treads 11 Risers 12 Strings 13 Splashbacks 14 Fascias 15 Linings to channels 16 Coverings to curbs 17 Cappings 18 Cornices 19 Extra over for
1 Dimensioned description
1 Curved, radii stated 2 Flat rigid tiles or slabs set to curve 3 Patterned, details stated 4 External
C5 Linings to channels and coverings to curbs are held to include additional finishes to ends
1 Dimensioned description
m No
1 Curved, radii stated 2 Flat rigid tiles or slabs set to curve 3 Patterned, details stated 4 External
M4 Large feature patterns may alternatively be measured net and not extra over
20 Movement joints
1 Dimensioned description
09300/3
09550/1
CLASSIFICATION TABLE
1 Floors 2 Landings
3 Treads 4 Risers
1 Width stated
D1 Work is held to be internal unless described as external D2 The thickness stated is the nominal thickness D3 Rounded angles >100mm radius are classified as curved work
C1 Work is held to include: (a) laying to rounded edges, angles and intersections where <100mm radius except where formed with special units which are measured separately (b) fair joints to all types of work including to existing (c) all jointing materials (d) all fixing materials including bedding mortars, adhesives and mechanical fixings (e) cleaning, sealing and polishing (f) cutting and fitting into recessed duct and manhole covers (g) dishing to outlets and gullies (h) all cutting and fitting over and around obstructions including cutting and fitting up to frames and around pipes, brackets and the like (i) cutting holes (j) preparing bases including hacking concrete to form a key (k) bonding agents where necessary or required (l) sundry items of a like nature
09650/1
09650/2
CLASSIFICATION TABLE 1 Floors 2 Landings 3 Walls and columns 4 Worktops, vanity tops, seats and the like 2 Contrasting bands and margins < 300mm wide, width stated 1 Dimensioned description m 1 Dimensioned description m 1 Floors sloping >15 2 Curved 3 Patterned, details stated 4 External M2 Contrasting bands and margins are only measured separately in meters where < 300mm wide. Where bands and margins are > 300mm wide they are measured as general areas of finishes in square meters D4 Floors include to floors within roof spaces D5 Walls and columns include edges of openings, recesses and projections on walls and columns C2 Floors are held to include for laying to falls, currents and slopes < 15
C3 Linings to channels and coverings to curbs are held to include additional finishes to ends
10 Coverings to curbs 11 Extra over for 1 Special patterns 2 Special units 1 Dimensioned description m no 1 Curved 2 Patterned, details stated 3 External M3 Large feature patterns may alternatively be measured net and not extra over D6 Special units include special units to provide rounded edges, angles and intersections
09795/1
09900 Painting
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 The area or girth measured is the area or girth covered including allowances for the extra girth of edges, mouldings, panels, sinkings, corrugations, carvings and the like, except where otherwise stated M2 No deduction is made for voids <0.50m DEFINITION RULES D1 Work is held to be internal unless described as external D2 Where reference is made to painting it is held to include clear finishing and polishing D3 Preparation includes all preparation necessary to the surface to receive the paint system described including putty, fillers, sealers and the like COVERAGE RULES C1 Work is held to include: (a) preparation of surfaces (b) rubbing down between coats (c) cutting to line (d) painting to corrugated, fluted, panelled, carved, ornamental or other irregular surfaces (e) removing hardware and the like and replacing after painting (f) painting hinges, fastenings, fixings and the like
09900/1
SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Nature of base S3 Preparatory work S4 Priming or sealing coats (No) S5 Undercoats (No) S6 Finishing coats (No) and surface finish S7 Method of application S8 If moulded, panelled, corrugated or carved surfaces are measured flat this is stated in the description
CLASSIFICATION TABLE
1 Floors 2 Landings 3 Walls and columns 4 Doors 5 Glazed doors 6 Glazed windows and screens 7 Door frames, linings and cills 8 Louvers and grilles 9 Baseboards, dado rails, cornices, coves and the like 10 Fascias and eaves soffits 11 Treads, risers and strings 12 Cabinets, wardrobes and the like 13 Ceilings and beams 14 Soffits of staircases and landings
M3 Doors, windows and screens are measured flat both sides and include integral louvers M4 Doors with viewing panels only are described as doors and not glazed doors M5 Louvers and grilles are measured flat both sides
D4 Baseboards, dado rails, cornices, coves and the like include: (a) window boards (b) mouldings to walls and ceilings (c) all similar linear items
C2 Painting to glazed surfaces are held to include: (a) work to edges of opening lights (b) work to the surrounding frame caused by opening lights (c) cutting in next to glass (d) work on glazing beads
m m
1 Height to soffit >3.50m above floor in stages of 1.50m 2 External 3 On site before fixing
D5 Beams attached to ceilings are classified as the same height to soffit as the ceiling where the finish is the same in nature
15 Structural metalwork
1 General surfaces
1 External
2 Intumescent coatings
1 Fire rating and cross sectional shape, size and weight per meter 2 Number of coats
C3 Work to structural metalwork is held to include the additional area due to: (a) attached bolts, clips and the like (b) connections, caps and bases
09900/2
09900/3
2 Close type 3 Mesh covered or ornamental 17 Pipes, conduit and the like 18 Gutters 1 Girth > 300mm
D6 Pipes, conduit and the like include cables, ducting and trunking
C4 Pipes, conduit and the like are held to include work to: (a) supports (b) conduit boxes and other fittings (c) pipe fittings and accessories C5 Gutters are held to include work to supports and fittings
19 Lines
1 Width stated
1 Broken 1 Curved
1 Dimensioned description
No
21 Signwriting
1 Dimensioned description
No
09950 Paperhanging
INFORMATION TO BE PROVIDED MEASUREMENT RULES M1 No deduction is made for voids <0.50m DEFINITION RULES D1 Work is held to be internal unless described as external D2 Preparation includes all preparation necessary to the surface to receive the paperhanging described including putty, fillers, sealers and the like m 1 External COVERAGE RULES C1 Work is held to include: (a) preparation of surfaces (b) removing fixtures, fittings, equipment and the like and replacing after paperhanging (c) cutting or fitting around obstructions, intrusions or projections SUPPLEMENTARY INFORMATION S1 Kind and quality of materials S2 Nature of base S3 Preparatory work S4 Method of fixing and jointing
4 Border strips
1 External
5 Corners 6 Motifs
No
1 External
09950/1
10150/1
10200/1
10270/1
CLASSIFICATION TABLE 1 Floors 1 Dimensioned description 1 Height of cavity stated m 1 Integral fittings, details stated 2 Sloping > 15 3 Patterned, details stated 4 External 2 Downstands 3 Steps in surfaces 2 Curved, radii stated 3 Patterned, details stated 4 External 4 Ramps 5 Steps 2 Patterned, details stated 3 External 6 Extra over for 1 Access panels 2 Special panels 7 Baseboards 1 Dimensioned description m 1 Curved, radii stated 2 External M3 Baseboards which are part of the raised floor system are measured here. Baseboards not part of the raised floor system are measured in the relevant sections C3 Work is held to include fair ends, angles and intersections 1 Dimensioned description No 1 External 1 Dimensioned description No 1 Integral fittings, details stated 1 Dimensioned description m 1 Integral fittings, details stated M2 Integral fittings are included with the floor where part of the raised floor system and they also follow a regular layout. Where fittings are not part of the raised floor system or do not follow a regular layout they are measured separately in accordance with 10270.6.*.*.* D2 Integral fittings include special panels and the like C2 Work is held to include for laying to falls, currents and slopes < 15
10270/2
10430/1
10615/1
10615/2
CLASSIFICATION TABLE 1 Demountable partitions 1 Height and thickness stated m 1 Baseboards one side 2 Baseboards both sides 3 Flat panels set out to a curve 4 Curved, radii stated M1 Work is measured over obstructions M2 Baseboards are only included where supplied with the demountable partition system
2 Stop ends 3 Angles 4 Three way intersections 5 Four way intersections 6 Abutments with walls and columns 7 Extra over for doors 8 Extra over for glazed screens 9 Extra over for blank openings
1 Dimensioned description
1 Dimensioned description
No
C2 Work is held to include (a) frames and linings (b) hardware (c) architraves (d) glazing beads (e) glass (f) all other ancillary trims, supports, components and incidental work for the proper execution of the item
S6 Details of frames, linings, hardware, architraves, glazing beads, glass and the like
No
10800/1
CLASSIFICATION TABLE
14000/1
14000/2
Identification, color coding and labelling Marking positions of holes, mortices, chases and the like in the structure Cutting holes, mortices, chases and the like, grouting and making good after installation Providing all sleeves for fixing through slabs, walls, beams and the like
1 Details stated
item
1 Details stated
item
10 Wrapping conduits, cables or trunking pipes in felt or similar protection where they pass through slabs, walls, beams and the like 11 Sealing, packing and fireproofing where work pass through slabs, walls, beams and the like
1 Details stated
item
C6 Testing and commissioning is held to include: (a) provision of water, fuel, gas, electricity and other supplies (b) provision of test certificates (c) making good all defects and re-testing as necessary
item
14000/3
14000/4
S4 Details of: (a) servicing requirements and frequency (b) requirements for emergency call outs (c) requirements in respect of repairs and who pays for damaged or replacement parts
12600/1
CLASSIFICATION TABLE
No
C2 Work is held to include fixing to any other backgrounds as necessary, even though the material of the main component is the only one stated
16000/1
CLASSIFICATION TABLE
1 Conduits
1 Wrapping 2 External
M2 Conduit is measured over all fittings and boxes M3 Trenches, chambers and beds for underground services are measured in Section 02605 - Utility Trenches and Structures
D2 Surface fixed conduit includes: (a) conduit fixed to surfaces which are subsequently covered by suspended ceilings, raised floors, access panels and the like (b) conduit fixed in ducts or pipe chases (c) conduit generally surface fixed but embedded for short parts of their lengths as required by the installation
C3 Conduit is held to include: (a) pull wires (b) joints in the running length (c) joints to boxes and distribution boards (d) expansion joints, flexible conduits and adaptors (e) bends, junctions and all other fittings (except for boxes designed by the Electrical Engineer) (f) boxes where necessary but not designed by the Electrical Engineer (g) all labors including made bends (h) components for grounding (i) sundry items of a like nature C4 Embedded conduit is held to include: (a) casting into concrete, plaster and toppings (b) cutting chases in any materials and making good C5 Conduit encased in concrete is held to include: (a) concrete (b) reinforcement (c) excavation and breaking out as necessary (d) backfilling with selected excavated material or as otherwise specified
16000/2
16000/3
(f)
2 Boxes
No
1 External
M4 Boxes are only measured separately where designed by the Electrical Engineer. Where not designed but necessary for the installation they are held to be included with the conduit by Rule C3(f)
D3 Boxes include pull boxes, junction boxes, adaptable boxes, floor trap boxes, purpose made boxes, flameproof boxes and all other special boxes
1 Surface fixed
1 External
M5 Wireways, cable ladders, underfloor ducts and busducts are measured over all fittings
D4 Surface fixed wireways, cable ladders and cable trays include: (a) fixed to surfaces which are subsequently covered by suspended ceilings, raised floors, access panels and the like (b) fixed in ducts or pipe chases (c) generally surface fixed but embedded for short parts of their lengths as required by the installation
5 Underfloor ducts
C6 Wireways, cable ladders, underfloor ducts and busducts are held to include: (a) joints in the running length (b) joints to conduit and distribution boards (c) joints to fittings (d) all labors (e) components for grounding
6 Busducts
1 External
1 Fittings
No
1 External
D5 Fittings include end caps, bends, tees, crosses, reducers and the like
C7 Connections to equipment include lugs C8 Cable trays are held to include: (a) joints in the running length (b) joints to accessories and equipment (c) joints to fittings (d) all labors including cutting openings (e) components for grounding
1 Fittings 2 Tap off units 3 Feeder units 4 Plug in circuit breakers, ampacity rating stated 5 Expansion joints 6 Special fittings 7 Connections to equipment
No
1 External
10 Cable trays
1 Surface fixed
1 External
16000/4
16000/5
12 Cables
1 Drawn into conduits, ducts or wireways 2 Drawn into existing conduits, ducts or trunking 3 Fixed to cable trays or ladders 4 Surface fixed 5 Embedded 6 Wrapping around pipework or equipment 7 Laid in trenches
1 External
M6 Cable is measured the net length following the shortest distance between points in straight lines except that the following allowances are added for tails: (a) 0.30m on each cable entering lighting fixtures and accessories (b) 0.60m on each cable entering equipment and control gear (i.e. motors, transformers, panelboards, disconnect switches, enclosed circuit breakers and the like).
D7 Surface fixed cables include: (a) cables fixed to surfaces which are subsequently covered by suspended ceilings, raised floors, access panels and the like (b) cables generally surface fixed but drawn into conduits, ducts or wireways, fixed to cable trays or embedded for short parts of their lengths as required by the installation
C9 Cables are held to include: (a) all labors (b) all joints where not designed by the Electrical Engineer but required for the installation (c) color coding or other identification markings C10 Cables drawn into existing conduit, ducts or wireways are held to include removing and replacing existing covers, inspection lids and the like C11 Embedded cables are held to include: (a) casting into concrete, plaster and toppings (b) cutting chases in any materials and making good
No
1 Shrouds 2 External
14 Grounding conductors
1 External
C12 Grounding conductors are held to include: (a) all labors (b) all joints (c) color coding or other identification markings
No No
17 Ground wells
1 Details stated
No
18 Final circuits
1 Lighting points, stating whether wall or ceiling mounted and whether centrally or locally controlled 2 Switch points, stating whether one or two way and the number of gangs 3 Intermediate switch points 4 Socket outlet points 5 Immersion heater points 6 Cooker points 7 Fan points 8 Air conditioner points 9 Others, stated
No
M7 Final circuits are measured on an enumerated points basis where they form part of a domestic or similar simple installation from distribution boards and the like M8 Each lighting point is measured as one point irrespective of the number of lamps M9 Socket outlet points, switch points and the like are measured as one point irrespective of the number of gangs
D8 Surface fixed include: (a) work fixed to surfaces which are subsequently covered by suspended ceilings, raised floors, access panels and the like (b) work generally surface fixed but embedded for short parts of their lengths as required by the installation
C13 Final circuits are held to include: (a) providing distribution diagrams and location drawings showing the layout of the points (b) all conduit fittings and accessories necessary for the installation (c) all cable fittings and accessories necessary for the installation (d) all work to conduits included in Rule C3 (e) all work to cables included in Rule C9. C14 Embedded final circuits are held to include: (a) casting into concrete, plaster and toppings (b) cutting chases in any materials and making good
16000/6
16000/7
S5 Details of links, fuses, circuit breakers, gland plates, terminal boxes and the like
No
1 External
D10 Accessories and field devices include switches, socket outlets, thermostats, bell pushes, signal indicating units, clocks, telephones, alarm bells, loudspeakers, door status, smoke detectors, heat detectors and the like
C16 Work is held to include: (a) boxes, connector blocks (b) connections to conduit, wireways, cable trays and cable (c) all necessary ancillary work including bushes, nipples, locknuts and the like (d) grounding (e) all supports as necessary for fixing
S6 Lighting fixtures are to include details of reflectors, shades, lamps and the like S7 Accessories are to state number of gangs where appropriate
1 Details stated
item
27 Marking positions of holes, mortices, chases and the like in the structure 28 Cutting holes, mortices, chases and the like, grouting and making good after installation 29 Providing all sleeves for fixing through slabs, walls, beams and the like 30 Wrapping conduits, cables or trunking in felt or similar protection where work passes through slabs, walls, beams and the like 31 Sealing, packing and fireproofing where work passes through slabs, walls, beams and the like 32 Providing all necessary spares and tools 33 Testing and commissioning
1 Details stated
item
1 Details stated
item
C17 Testing and commissioning is held to include: (a) provision of water, fuel, gas, electricity and other supplies (b) provision of test certificates (c) making good all defects and re-testing as necessary
16000/8
16000/9
36 Temporary operation of installations to Owner's requirements 37 Instruction of Owner's representatives in operation, maintenance, preventive maintenance and service of completed installation
1 Details stated
1 Duration stated
item
C18 Provision of water, fuel, gas, electricity and other supplies are held to be included
38 Maintenance
1 Details stated
1 Duration stated
item
S8 Details of: (a) servicing requirements and frequency (b) requirements for emergency call outs (c) requirements in respect of repairs and who pays for damaged or replacement parts
CLASSIFICATION TABLE
15000/1
15000/2
2 Circular ducts
1 Nominal size
No
4 Extra over rectangular ducts for 5 Extra over circular ducts for
No
No
M4 Reducing fittings are measured extra over the largest of the ducts on which they occur
C5 Fittings are held to include stiffeners, turning vanes, splitters, access doors and the like
6 Ancillaries 7 Equipment
No
3 Volume control dampers and fire dampers not designed by the Mechanical Engineer
item
M5 These item are included in the bills of quantities even if volume control dampers and fire dampers are designed by the Mechanical Engineer, so that any additional volume control dampers and fire dampers required by the Contractor can be allowed for
D2 Ancillaries include diffusers, dampers designed by the Mechanical Engineer, grilles, louvers and the like D3 Equipment includes chillers, cooling towers, air handling units, fans, boilers, tanks, heat exchangers, pumps and the like
C6 Ancillaries and equipment are held to include: (a) supporting frames (b) anti vibration mountings (c) sound insulating materials (d) insulation where supplied with the unit (e) controls and switches where supplied with the unit (f) wires and conduit to controls and switches
4 Linear diffusers
1 Dimensioned description
m No
C7 Linear diffusers are held to include ends, capped ends, angles and intersections M6 Work is measured in accordance with Section 15400 - Plumbing
8 9
15000/3
15000/4
No
4 To pipes
M8 Insulation to fittings on pipes is only measured where the pipe is >60mm diameter
No
C10 Insulation is held to include: (a) smoothing the materials and working around supports (b) working around pipe flanges (c) working around fittings <60mm diameter
7 Equipment
No
1 Details stated
item
15 Marking positions of holes, mortices, chases and the like in the structure 16 Cutting holes, mortices, chases and the like, grouting and making good after installation 17 Providing all pipe, duct, conduit or cable sleeves for fixing through slabs, walls, beams and the like 18 Wrapping pipes, ducts, conduits, cables or trunking in felt or similar protection where they pass through slabs, walls, beams and the like 19 Sealing, packing and fireproofing where pipes, ducts, conduits, cables or trunking pass through slabs, walls, beams and the like
1 Details stated
item
15000/5
15000/6
22 Preparing drawings required by the Owner 23 Operating and maintenance manuals 24 Temporary operation of installations to Owner's requirements 25 Instruction of Owner's representatives in operation, maintenance, preventive maintenance and service of completed installation 26 Maintenance
item
1 Details stated
1 Duration stated
item
C12 Provision of water, fuel, gas, electricity and other supplies are held to be included
1 Details stated
1 Duration stated
item
S4 Details of: (a) servicing requirements and frequency (b) requirements for emergency call outs (c) requirements in respect of repairs and who pays for damaged or replacement parts
15000/7
CLASSIFICATION TABLE
15300/1
15300/2
2 Pipes
1 To walls and columns 2 To floors 3 To ceilings and soffits 4 Cast into mat foundations 5 In trenches
1 Wrapping
1 Dimensioned description
No
M6 Fittings on pipes are only measured where >60mm diameter M7 Reducing fittings are measured extra over the largest of the pipes or gutters on which they occur and include for separate reducers where a fitting of the required sizes is not available
D1 Fittings on gutters include angles, stopped ends and outlets D2 Fittings on pipes include bends, junctions, reducers, offsets, access pipes, boss joints, end caps and the like D3 Special joints and connections are: (a) joints which differ from those generally occurring in the running length (b) connections to gutters or pipes of a different profile or material (c) connections to existing gutters or pipes
C6 Fittings are held to include providing fittings with outlets at any angle as required
1 Fittings 2 Special joints and connections designed by the Mechanical/ Sanitary Engineer 3 Flexible connectors, flexible pipes and expansion loops designed by the Mechanical/Sanitary Engineer
1 Dimensioned description
No
4 Flexible connectors, flexible pipes, expansion loops and special joints and connections not designed by the Mechanical/Sanitary Engineer
item
M8 This item is included in the bills of quantities, even if the work is designed by the Mechanical/Sanitary Engineer, so that any additional work required by the Contractor can be allowed for
5 Ancillaries 6 Equipment
No
D4 Ancillaries include drains, cleanouts, sprinkler heads, valves, meters and the like D5 Equipment includes boilers, cisterns, cylinders, tanks, pumps and the like
15300/3
15300/4
2 To fittings, type stated 3 To ancillaries, type stated 4 To Equipment 9 Identification, color coding and labelling 10 Marking positions of holes, mortices, chases and the like in the structure 11 Cutting holes, mortices, chases and the like, grouting and making good after installation 12 Providing all pipe, conduit or cable sleeves for fixing through slabs, walls, beams and the like 13 Wrapping pipes, conduit, cables or trunking in felt or similar protection where they pass through slabs, walls, beams and the like 1 Details stated
No
No item
1 Details stated
item
14 Sealing, packing and fireproofing where pipes, conduits, cables or trunking pass through slabs, walls, beams and the like 15 Providing all necessary spares and tools 16 Testing and commissioning 17 Treatment of completed installations 1 Details stated item D6 Treatment of completed installations includes disinfecting water distribution systems C8 Testing and commissioning is held to include: (a) provision of water, fuel, gas, electricity and other supplies (b) provision of test certificates (c) making good all defects and re-testing as necessary
item
20 Temporary operation of installations to Owners requirements 21 Instruction of Owners representatives in operation, maintenance, preventive maintenance and service of completed installation
1 Details stated
1 Duration stated
item
C9 Provision of water, fuel, gas, electricity and other supplies are held to be included
15300/5
15300/6
S4 Details of: (a) servicing requirements and frequency (b) requirements for emergency call outs (c) requirements in respect of repairs and who pays for damaged or replacement parts
CLASSIFICATION TABLE 1 Fixtures 2 Faucets 3 Flush valves 4 Shower heads 5 Shower valves 1 Dimensioned description No D1 Fixtures include water closets, urinals, lavatories, sinks, bath tubs, hand dryers and the like
15440/1
Index
Access flooring..................................... Access hatches, metal............................ Access hatches, wood............................ Alterations............................................ Air terminals. Anchor bolts, to structural steel............ Angle fillets, cement............................. Asphalt, roofs........................................ Asphalt, waterproofing.......................... Balustrades, plastic............................... Balustrades, plain metal........................ Balustrades, ornamental metal.............. Balustrades, external............................. Balustrades, wood................................. Bar reinforcement................................. Baseboards, plastic................................ Baseboards, wood.................................. Baseboards, metal.................................. Bathroom accessories............................ Battens, wood...................................... . Boarding, wood..................................... Bolts, for wood.................................... Boxes, electrical Brick walls........................................... Broom finish to concrete...................... Building automation system. Busducts... Cables Cable ladders. Cable trays. Carpentry, finish carpentry.................... 10270 08100.5 08210.4 02050.3 16000.15 05100.11 03500.15 07540 07120 06600.4 05500.4 05700.4 02840.2 06400.2 03200.1 06600.16 06200.1 05500.16 10800 06100.2.2 06160 06100.5 16000.2 04200.3 03345.1.4 13800 16000.6 16000.12 16000.4 16000.10 06200 Carpentry, sheet and board linings........ Carpentry, architectural woodwork...... Carpentry, rough................................... Carpentry, panelling............................. Carpet.................................................... Cast in place concrete, to roads etc....... Ceramic tiles.......................................... CHB walls............................................. Cladding, profiled sheets....................... Cladding rails, cold rolled metal........ Clearing site vegetation........................ Column guards, plastic.......................... Column guards, metal............................ Compartments...................................... Concrete, cast in place.......................... Concrete, surface finishes...................... Concrete, precast................................... Concrete slabs and tiles......................... Concrete, filling steel hollow sections.. Concrete hollow block walls................. Concrete, joints..................................... Concrete, precast post tensioned........... Conduit. Conveying systems Cornices, wood...................................... Cubicles................................................. Cultivating ground................................. Curtain walls......................................... Cutting and forming openings............... 06160 06400 06100 06160 09680 02500.5 09300 04200.1 07400.2 05100.14 02100.1.3 06600.15 05500.15 10150 03300 03345 03400 09300 05100.16 04200.1 03250.1 03420 16000.1 14000 06200.3 10150 02900.2 08900 02050.3.1 Diaphragm walls................................... Disconnect switches. Division Strips, for finishes................. Doors, wood........................................... Doors, plastic......................................... Doors, metal.......................................... Doors, frameless glass.......................... Drainage, underground.......................... Duct covers, wood................................ Ducts, for utilities................................. Ducts, circular.. Ducts, flexible.. Ducts, rectangular. Dumbwaiters.. Earthwork............................................. Eaves soffits, wood sheet and board..... Eaves soffits, solid wood....................... Electrical installations.. Electrodes. Elevators Enclosed circuit breakers.. Equipment, drainage. Equipment, electrical. Equipment, fire protection Equipment, mechanical Equipment, maintenance.. Escalators. Excavating, utility trenches.................. Excavating, drainage trenches............... Excavating............................................ Excavation support systems................. Expansion joint covers, metal.............. 02250 16000.21 09795.2 08210 08220 08100 08400 02700 06200.13 02605.6 15000.2 15000.3 15000.1 14000.2 02200 06160.5 06200.11 16000 16000.16 14000.3 16000.22 02700.9 16000.19 15300.6 15000.7 11010 14000.4 02605.1 02700.1 02200.1 02160 05500.14
Index/1
Index
Expansion joint covers, plastic.............. 06600.14 Fabric reinforcement............................. Fascias, solid wood................................ Fascias, wood sheet and board.............. Faucets.. Fencing, temporary............................... Fencing, temporary for planting............ Fencing.................................................. Field devices.. Filling existing openings....................... Filling, to excavations........................... Filling, base courses to roads etc........... Finishes, resilient flooring..................... Finishes, paperhanging.......................... Finishes, carpet...................................... Finishes, suspended ceilings.................. Finishes, tile and slab........................... Finishes, trims, division strips, nosings Finishes, wood flooring........................ Finishes, painting................................... Fire extinguishers.. Fire Protection.. Fixtures and fittings, ornamental metal. Fixtures and fittings, plain metal........... Fixtures and fittings, plastic.................. Fixtures and fittings, wood .................. Fixtures and fittings, external................ Flush valves.. Folding partitions, wood........................ Formwork............................................. Framework, wood................................. Framework, metal................................ Furniture, external................................. 03200.2 06200.10 06160.4 15440.2 01520 02900.17 02830.1 16000.25 02050.3.3 02200.5-8 02500.1-2 09650 09950 09680 09100 09300 09795 09550 09900 15300.7 15300 05700.11 05500.11 06600.11 06400.10 02840.1 15440.3 06400.9 03100 06100.3-4 09100.5-8 02840 Gates...................................................... Geotextiles, to roads etc........................ Glass, hacking out existing glass.......... Glass block walls................................... Glass...................................................... Gondola. Granite................................................... Grass turfing.......................................... Grass seeding......................................... Gratings, plastic.................................... Gratings, ornamental metal................... Gratings, plain metal............................. Grilles, ornamental metal...................... Grilles, plain metal................................ Grilles, plastic....................................... Ground wells. Grounds, wood...................................... Grouting under steel column bases....... Grounding conductors... Gutters.. Gypsum board....................................... Handrail brackets, plastic...................... Handrail brackets, ornamental metal..... Handrail brackets, plain metal............... Fixtures, plumbing. Handrails, external................................ Handrails, ornamental metal.................. Handrails, plain metal........................... Handrails, wood.................................... Handrails, plastic.................................. Hardware............................................... Hedge plants......................................... 02830.4 02500.16 08800.9 04200.4 08800 11010.1 09300 02900.5 02900.4 06600.13 05700.13 05500.13 05700.12 05500.12 06600.12 16000.17 06100.2.1 05100.15 16000.14 15400.1 09250 06600.10 05700.10 05500.10 15440.1 02840.4 05700.6 05500.6 06400.4 06600.6 08700 02900.10 Inspection chambers, utilities................ Inspection chambers, drainage............. Insulation.............................................. Insulation, mechanical.. Insulation, plumbing.. Joints in concrete................................... Joints, sealants....................................... Joists, wood.......................................... Ladders, plain metal.............................. Ladders, ornamental metal.................... Light coves........................................ Lighting fixtures Lintels................................................ Louvers, wood................................... Louvers, other than wood...................... Louvers, glass........................................ Manholes.............................................. Marble.................................................... Mechanical installations Metal fabrications................................. Metal, ornamental................................. Metal Lathing....................................... Metal support systems.......................... Mirrors.................................................. Mosaic tiles............................................ Mouldings, wood................................... Moving walks Mulch................................................... 02605.8 02700.10 07200 15000.13 15300.8 03250.1 07900 06100.1 05500.2 05700.2 09100.3 16000.23 04200.10 06400.8 10200 08800.6 02700.9 09300 15000 05500 05700 09205 09100 10800 09300 06200.2&4 14000.5 02900.16
Non-slip inserts..................................... 09795.4 Nosings, for finishes.............................. 09795.3 Nosings, wood....................................... 06200.7
Index/2
Index
Painting lines and symbols................. Painting................................................ Panelboards. Panelling, wood..................................... Paperhanging......................................... Parquet flooring..................................... Partitions, sliding/folding, wood........... Paving................................................... Piling, bored cast in place...................... Piling, contractor designed.................... Piling, precast concrete......................... Piling, steel sheet................................... Piling, cast in place in driven casings.... Piling, isolated steel.............................. Pipe casings, sheet and board............... Pipes, chilled water... Pipes, condensate. Pipes, condenser water. Pipes, fire protection Pipes, for underground drainage........... Pipes, refrigerant.. Pipes, fuel. Plants, relocating.................................. Plants.................................................... Plaster................................................... Plastic fabrications................................ Plumbing.. Plumbing fixtures. Plywood sheeting.................................. Pointing, sealants.................................. Portal frames, steel.............................. Power floating to concrete.................... Precast concrete.................................... 02500, 09900 09900 16000.20 06160 09950 09550 06400.9 02500 02370 02400 02362 02361 02363 02364 06160.6-7 15000.9 15000.10 15000.8 15300.1 02700.6 15000.11 15000.12 02900.15 02900 09220 06600 15400 15440 06160 07900 05100.7 03345.1.1 03400 Precast concrete, prestressed................ 03420 Purlins, cold rolled metal....................... 05100.14.1 Quarry tiles............................................ 09300 Railings, plain metal............................. Railings, ornamental metal.................... Railings, wood....................................... Railings, plastic.................................... Railings, external.................................. Reinforcement, to concrete.................. Removing existing work........................ Removing glass.................................... Removing trees...................................... Render................................................... Resilient flooring................................... Rock anchors......................................... Roller shutters, metal............................. Roofing, felt.......................................... Roofing, tiles........................................ Roofing, asphalt.................................... Roofing, profiled sheets........................ Roofing, sheet membrane...................... Roofing, fluid applied............................ Rooflights, plastic.................................. Rooflights, metal................................... Rooflights, wood................................... Rubbed finish to concrete...................... Screeds (toppings)................................. Screens, entrance.................................. Screens, wood........................................ Screens, plastic...................................... 05500.5 05700.5 06400.3 06600.5 02840.3 03200 02050.2 08800.9 02100.1.1 09220 09650 02160.1 08100.4 07510 07300 07540 07400.1 07510 07540 08630 08500.3 08610.3 03345.2.1 03500 08400 08610.4 08630 Screens, metal....................................... Sealants.................................................. Septic tanks........................................... Sewerage................................................ Sheeting, wood...................................... Shelves, glass......................................... Shelves, wood........................................ Shingles................................................. Shopfronts............................................. Shoring................................................. Shotcreting............................................ Shower heads. Shower valves... Shrubs, relocating................................. Shrubs, planting..................................... Signs, door. Signwriting............................................ Site preparation..................................... Sliding partitions, wood........................ Soft landscaping.................................... Soil nails................................................ Staircases, wood.................................... Staircases, plain metal........................... Staircases, ornamental metal................. Stone tiles and slabs.............................. Structural timber................................... Structural steelwork.............................. Suspended ceilings, wood framework... Suspended ceilings, metal lath.............. Suspended ceilings................................ 08500.4 07900 02700.11 02700 06160 08800.7 06200.12 07300 08400 02152 02160.3 15440.4 15440.5 02900.14 02900.9 10440.2 09900.21 02100 06400.9 02900 02160.2 06400.1 05500.1 05700.1 09300 06100.1 05100 06100.7 09205.6 09100
Index/3
Index
Tendons, designed by Engineer............. Tile and slab finishes........................... Timber framework............................... Timber, structural................................. Toilet accessories.................................. Toppings, cement.................................. Topsoil, general filling.......................... Topsoil, soft landscaping...................... Trees, removing..................................... Trees, planting...................................... Trees, relocating.................................... Trees, protecting................................... Trims, for finishes................................. Trowelling to concrete.......................... Trusses, steel........................................ Trusses, wood....................................... 03230 09300 06100.3-4 06100.1 10800 03500 02200.4 02900.1 02100.1.1 02900.7-8 02900.13 02100.2 09795.1 03345.1.2 05100.6 06100.1.3 Waterproofing, fluid applied, roofs....... Waterproofing, sheet membrane........... Waterproofing, asphalt, roofs............... Waterproofing, felt............................... Wedging under steel column bases....... Window shutters, metal......................... Window boards, metal........................... Window shutters, wood......................... Window boards, wood........................... Window boards, plastic......................... Windows, plastic................................... Windows, wood..................................... Windows, metal.................................... Wireways.. Wood strip flooring............................... Wood flooring....................................... Wood block flooring.............................. 07540 07110 07540 07110 05100.15 08500.2 05500.17 08610.2 06200.9 06600.17 08630 08610.1 08500.1 16000.3 09550 09550 09550
Underfloor ducts 16000.5 Unit masonry........................................ 04200 Utility Trenches..................................... 02605 Vapor barriers........................................ Vents..................................................... Vinyl tiles............................................... Vinyl sheet............................................. Walkways, plain metal.......................... Walkways, ornamental metal................ Water distribution. Waterproofing, fluid applied................. Waterproofing, sheet membrane, roofs. Waterproofing, asphalt.......................... Waterproofing, felt, roofs...................... 07190 10200 09650 09650 05500.3 05700.3 02660 07120 07510 07120 07510
Index/4
Index
Index/5