Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 2 of 114

Table of Contents
1.0

Introduction ...................................................................................................................... 6

2.0

Piping loop having Document number A375-000-16-43-ADC-0018 ................................. 7

2.1

PROPOSED RETROFITTING ...................................................................................... 7

2.2

RESULTS AFTER RETROFITTING ............................................................................. 7

2.3

CONCLUSION ............................................................................................................. 9

3.0

Piping loop having Document number A375-000-16-43-ADC-0020 ............................... 10

3.1

PROPOSED RETROFITTING .................................................................................... 10

3.2

RESULTS AFTER RETROFITTING ........................................................................... 10

3.3

CONCLUSION ........................................................................................................... 12

4.0

Piping loop having Document number A375-000-16-43-ADC-0044 .............................. 13

4.1

PROPOSED RETROFITTING .................................................................................... 13

4.2

RESULTS AFTER RETROFITTING ........................................................................... 13

4.3

CONCLUSION ........................................................................................................... 18

5.0

Piping loop having Document number A375-000-16-43-ADC-0046 .............................. 19

5.1

PROPOSED RETROFITTING .................................................................................... 19

5.2

RESULTS AFTER RETROFITTING ........................................................................... 19

5.3

CONCLUSION ........................................................................................................... 22

6.0

Piping loop having Document number A375-000-16-43-ADC-0049 .............................. 23

6.1

PROPOSED RETROFITTING .................................................................................... 23

6.2

RESULTS AFTER RETROFITTING ........................................................................... 23

6.3

CONCLUSION ............................................................................................................... 25

7.0

Piping loop having Document number A375-000-16-43-ADC-0051 .............................. 26

7.1

PROPOSED RETROFITTING .................................................................................... 26

7.2

RESULTS AFTER RETROFITTING ........................................................................... 26

7.3

CONCLUSION ........................................................................................................... 30

8.0

Piping loop having Document number A375-000-16-43-ADC-0054 ............................... 31

8.1

PROPOSED RETROFITTING .................................................................................... 31

8.2

RESULTS AFTER RETROFITTING ........................................................................... 31

8.3

CONCLUSION ........................................................................................................... 34

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


9.0

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 3 of 114

Piping loop having Document number A375-000-16-43-ADC-0056 .............................. 35

9.1

PROPOSED RETROFITTING .................................................................................... 35

9.2

RESULTS AFTER RETROFITTING ........................................................................... 35

9.3

CONCLUSION ........................................................................................................... 37

10.0

Piping loop having Document number A375-000-16-43-ADC-0059 ............................... 38

10.1

PROPOSED RETROFITTING .................................................................................... 38

10.2

SPRING DETAILS: .................................................................................................... 38

10.3

CONCLUSION ........................................................................................................... 42

11.0

Piping loop having Document number A375-000-16-43-ADC-0062 ............................... 43

11.1

PROPOSED RETROFITTING .................................................................................... 43

11.2

RESULTS AFTER RETROFITTING ........................................................................... 43

11.3

CONCLUSION ........................................................................................................... 45

12.0

Piping loop having Document number A375-000-16-43-ADC-0063 .............................. 46

12.1

PROPOSED RETROFITTING .................................................................................... 46

12.2

RESULTS AFTER RETROFITTING ........................................................................... 46

12.3

CONCLUSION ........................................................................................................... 50

13.0

Piping loop having Document number A375-000-16-43-ADC-0065 .............................. 51

13.1

PROPOSED RETROFITTING .................................................................................... 51

13.2

RESULTS AFTER RETROFITTING ........................................................................... 51

13.3

CONCLUSION ........................................................................................................... 53

14.0

Piping loop having Document number A375-000-16-43-ADC-0067 .............................. 54

14.1

PROPOSED RETROFITTING .................................................................................... 54

14.2

RESULTS AFTER RETROFITTING ........................................................................... 54

14.3

CONCLUSION ........................................................................................................... 56

15.0

Piping loop having Document number A375-000-16-43-ADC-0068 .............................. 57

15.1

PROPOSED RETROFITTING .................................................................................... 57

15.2

RESULTS AFTER RETROFITTING ........................................................................... 57

15.3

CONCLUSION ........................................................................................................... 57

16.0
16.1

Piping loop having Document number A375-000-16-43-ADC-0069 .............................. 58


PROPOSED RETROFITTING .................................................................................... 58

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 4 of 114

16.2

RESULTS AFTER RETROFITTING ........................................................................... 58

16.3

CONCLUSION ........................................................................................................... 60

17.0

Piping loop having Document number A375-000-16-43-ADC-0070 ............................... 61

17.1

PROPOSED RETROFITTING .................................................................................... 61

17.2

RESULTS AFTER RETROFITTING ........................................................................... 61

17.3

CONCLUSION ........................................................................................................... 63

18.0

Piping loop having Document number A375-000-16-43-ADC-0071 ............................... 64

18.1

PROPOSED RETROFITTING .................................................................................... 64

18.2

RESULTS AFTER RETROFITTING ........................................................................... 64

18.3

CONCLUSION ........................................................................................................... 67

19.0

Piping loop having Document number A375-000-16-43-ADC-0072 .............................. 68

19.1

PROPOSED RETROFITTING .................................................................................... 68

19.2

RESULTS AFTER RETROFITTING ........................................................................... 68

19.3

CONCLUSION ........................................................................................................... 69

20.0

Piping loop having Document number A375-000-16-43-ADC-0073 ............................... 70

20.1

PROPOSED RETROFITTING .................................................................................... 70

20.2

RESULTS .................................................................................................................. 70

20.3

CONCLUSION ........................................................................................................... 72

21.0

Piping loop having Document number A375-000-16-43-ADC-0081 ............................... 73

21.1

PROPOSED RETROFITTING .................................................................................... 73

21.2

RESULTS AFTER RETROFITTING ........................................................................... 73

21.3

CONCLUSION ........................................................................................................... 78

22.0

Piping loop having Document number A375-000-16-43-ADC-0089 .............................. 79

22.1

PROPOSED RETROFITTING .................................................................................... 79

22.2

RESULTS AFTER RETROFITTING ........................................................................... 79

22.3

CONCLUSION ........................................................................................................... 80

23.0

Piping loop having Document number A375-000-16-43-ADC-0090 .............................. 81

23.1

PROPOSED RETROFITTING .................................................................................... 81

23.2

RESULTS AFTER RETROFITTING ........................................................................... 81

23.3

CONCLUSION ........................................................................................................... 82

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


24.0

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 5 of 114

Piping loop having Document number A375-000-16-43-ADC-0093 .............................. 83

24.1

PROPOSED RETROFITTING .................................................................................... 83

24.2

RESULTS AFTER RETROFITTING ........................................................................... 83

24.3

CONCLUSION ........................................................................................................... 85

25.0

Piping loop having Document number A375-000-16-43-ADC-0095 .............................. 86

25.1

PROPOSED RETROFITTING .................................................................................... 86

25.2

RESULTS AFTER RETROFITTING ........................................................................... 86

25.3

CONCLUSION ........................................................................................................... 88

26.0

Piping loop having Document number A375-000-16-43-ADC-0096 .............................. 89

26.1

PROPOSED RETROFITTING .................................................................................... 89

26.2

RESULTS AFTER RETROFITTING ........................................................................... 89

26.3

CONCLUSION ........................................................................................................... 91

27.0

Piping loop having Document number A375-000-16-43-ADC-0097 .............................. 92

27.1

PROPOSED RETROFITTING .................................................................................... 92

27.2

RESULTS AFTER RETROFITTING ........................................................................... 92

27.3

CONCLUSION ........................................................................................................... 93

APPENDIX ( EIL Piping Support Standard )....94

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


1.0

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 6 of 114

Introduction

Piping loops had been stress analyzed according to supports marked in isometrics provided by
HWB and twenty-six loops did not qualify the design adequacy re-evaluation. For these loops,
retrofitting has been proposed. The piping stress analysis has been carried out again for these
loops incorporating the proposed retrofitting. This report presents the retrofitting arrangements,
the results and conclusions of the piping stress analysis after incorporating these changes in
these twenty-six piping loops. The isometrics marked with retrofit modifications are in a separate
CD. The relevant EIL piping support standards are included in the Appendix and may be
referred for the support details.

The following points may be noted with regard to retrofitting

1. The analysis has been carried out at design temperature, when normally wind and
seismic should be analyzed at operating conditions. Further the sustained and thermal
load cases should also be analysed.

2. The plant was designed as per B31.3 but the re-evaluation was requested to be carried
out as per ASME Section III, ND Class. Stress in piping has been checked as per ASME
Section-III ND Class. However HWB may ensure flexibility checking as per ANSI B 31.3,
before retrofitting as it was the original code for piping design in HWP (Manuguru).

3. The status of guides and other supporting (especially those on pipe racks were not
known, as isometrics for the same was not available, and some assumptions have been
made). The same needs to be first confirmed at site before any modification can be
carried out.

It should be noted that modifications in a plant running successfully for three decades
should be carried out with extreme care. This is applicable more so for piping because
guiding, restraining or strengthening a particular section may result in transfer of loads to
another section of piping or equipment nozzles not only for wind and seismic cases but
thermal case as well.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 7 of 114

Retrofitting Scheme for Piping


2.0 Piping loop having Document number A375-000-16-43-ADC-0018

2.1 PROPOSED RETROFITTING

Table 2.1 Proposed modifications in supports

Node
No.

Previous support

New Support

Remarks

3250

S3-A-1-6

S3-A-2-6

Guide in +Z with 52 mm gap, Guide -Z

2.2 RESULTS AFTER RETROFITTING


Table 2.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+ SUS
-X WIND+ SUS
+Z WIND+ SUS
-Z WIND+ SUS

Stresses (psi)
Actual

Allow.

% of
Allowable

14,954
26,846
24,312
25,835
25,278
22,471

22,322
28,286
24,749
24,749
24,749
24,749

67.0
95.0
98.0
104.0
102.0
91

Status
OK
OK
OK
MARGINAL
MARGINAL
OK

Table 2.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Load Case Description

Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

24,127

24,749

98

W+P1+F1+WIN1+SEISMIC (OCC)

57,339

24,749

232

W+P1+F1+WIN2+SEISMIC (OCC)

52,246

24,749

211

W+P1+F1+WIN3+SEISMIC (OCC)

29,998

24,749

121

10

W+P1+F1+WIN4+SEISMIC (OCC)

50,396

24,749

204

Status
OK
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 8 of 114

Retrofitting Scheme for Piping


DESIGN AND WIND (STATIC)
NODE: 1 (1ST STAGE COLD TOWER C106/206 NOZZLE F2)

NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

3 (OPE)

-193

5996

131

-5138.3

-37.4

-127.3

4 (SUS)

12

5592

127

-4866.8

6.7

112.2

5 (OPE)

-33

5979

134

-5127.6

64.9

-141.8

6 (OPE)

-256

5909

184

-5115.6

-54.8

-195.2

7 (OPE)

-164

6022

294

-5376.0

-132.2

-93.6

8 (OPE)

-172

5961

110

-5185.2

9.5

-103.3

MAX

-256/6

6022/7

294/7

-5376.0/7

-132.2/7

-195.2/6

NODE: 23400 (12-E-109/209B NOZZLE N1)


23400

3 (OPE)

545

141

-391

831.8

149.5

2.5

4 (SUS)

20

83

-5

155.1

-26.0

-566.6

5 (OPE)

-78

50

-227

501.3

491.6

-836.9

6 (OPE)

1050

209

-460

1011.8

-222.5

677.9

7 (OPE)

621

234

-819

1234.5

919.5

444.3

8 (OPE)

261

-23

274

22.3

-873.4

-805.5

MAX

1050/6

234/7

-819/7

1234.5/7

919.5/7

-836.9/5

NODE: 24300 (12-E-110/210 NOZZLE N2)


24300

3 (OPE)

-127

-231

257

378.6

-80.7

-56.0

4 (SUS)

-2

78

15

10.1

1.4

0.1

5 (OPE)

-223

-261

230

372.3

-172.1

-78.6

6 (OPE)

-159

246

358.1

31.5

-55.3

7 (OPE)

-103

-49

-38

197.4

-0.1

-29.1

8 (OPE)

-110

-414

487

526.4

-84.5

-97.2

MAX

-223/5

-414/8

487/8

526.4/8

-172.1/5

-97.2/8

NODE: 24400 (12-E-110/210 NOZZLE N1)


24400

3 (OPE)

677

-227

205

65.1

209.0

360.8

4 (SUS)

-51

15

68.9

-12.3

-30.8

5 (OPE)

209

-165

145

50.8

0.6

23.4

6 (OPE)

1042

-289

223

129.5

391.7

617.0

7 (OPE)

449

-182

-95

208.7

366.1

187.1

8 (OPE)

856

-316

452

-71.4

108.5

455.1

MAX

1042/6

-316/8

452/8

208.7/7

391.7/6

617.0/6

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 9 of 114

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
1
23400
24300
24400

FX
506
878
224
938

Load Case 7.
1
23400
24300
24400

345
411
319
470

Load Case 8.
1
23400
24300
24400

569
1383
99
1303

Load Case 9.
1
23400
24300
24400

477
954
199
710

Load Case 10.


1
23400
24300
24400

485
594
207
1116

Design + Seismic
FY
6244
251
352
321

FZ
233
720
345
342

MX
5374
1284
435
169

MY

MZ

271
896
269
447

477
507
99
555

299
1238
360
239

492
1342
122
218

289
969
219
630

545
1183
99
811

366
1666
188
604

443
949
72
381

243
1620
272
347

453
1310
140
649

Design +X Wind + Seismic


6227
160
382
259

237
556
318
281

5364
953
429
154

Design -X Wind + Seismic


6157
318
280
383

287
788
335
359

5352
1464
415
233

Design +Z Wind + Seismic


6270
343
170
275

396
1148
126
231

5612
1687
254
312

Design -Z Wind + Seismic


6209
133
535
409

213
603
575
588

5421
474
583
175

2.3 CONCLUSION
The piping stress analysis has been carried out for the piping from nozzles N1 & N2 of
Exchangers (12-E-109/209 & 12-E-110/210) to nozzle F2 of 1st Stage Cold Tower (12-C106/206) after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceeding the allowable stresses. Hence the system may be deemed to qualify the
design adequacy re-evaluation after retrofitting.
Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 10 of 114

3.0 Piping loop having Document number A375-000-16-43-ADC-0020

3.1 PROPOSED RETROFITTING


Table 3.1 Suggested modifications in supports

Node
No.

Previous support

5340

B42-1-325 & S4-A1-10

8010

L7A-2-1950-S

New Support
B42-1-325 , S4A-2-10 & S4-A5-10
L6-2-1950

Remarks
Cross Guide in X with 14 mm gap, Guide Z with 71.5
mm gap
Guide to be released

3.2 RESULTS AFTER RETROFITTING


Table 3.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+ SUS
-X WIND+ SUS
+Z WIND+ SUS
-Z WIND+ SUS

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

17,715
17,713
19,201
22,162
23,232
19,617

22,322
30,995
24,749
24,749
24,749
24,749

79.0
57.0
78.0
90.0
94.0
79.0

OK
OK
OK
OK
OK
OK

Allow.

% OF
Allowable

Status

24,749
24,749
24,749
24,749
24,749

95.0
81.0
85.0
91.0
79.0

OK
OK
OK
OK
OK

Table 3.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual
23,534
20,084
20,951
22,431
19,432

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 11 of 114

DESIGN AND WIND (STATIC)


NODE: 5 (12-V-102/202_F2)

NODE 5

Load Case
3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

FX Kg
-3
-0
-1
-6
-3
-3
-6/6

FY Kg
-826
-715
-503
-1199
-1013
-576
-1199/6

FZ Kg
112
82
289
-7
256
-169
289/5

MX Kg.m.
-738.2
73.0
-963.4
-486.3
-641.3
-619.8
-963.4/5

MY Kg.m.
-0.0
-0.0
-0.0
-0.0
-0.0
-0.0
-0.0/7

MZ Kg.m.
0.0
-0.0
0.0
0.0
0.0
0.0
0.0/8

-311
127
-310
-315
-601
15
-601/7

637.1
-224.6
670.2
691.2
825.9
422.1
825.9/7

-416.5
-185.2
-243.1
-626.8
-316.9
-459.0
-626.8/6

411.3
111.1
128.2
747.0
764.7
91.4
764.7/7

-303
-24
-308
-301
-564
-4
-564/7

1307.3
263.1
1336.1
1287.3
1500.3
1060.5
1500.3/7

-337.1
14.0
-104.0
-518.6
-254.8
-532.7
-532.7/8

155.6
-126.3
-135.5
417.2
433.7
-171.6
433.7/7

NODE: 16400 (EXCHANGER 12-E-102/202B_N1)


16400

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

309
-51
71
608
380
262
608/6

1158
791
1160
1232
1414
913
1414/7

NODE: 18400 (EXCHANGER 12-E-104/204B_N1)


18400

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

426
13
161
665
456
392
665/6

1160
498
1198
1128
1386
883
1386/7

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
5
16400
18400

FX
4
652
810

Load Case 7.
5
16400
18400

2
414
546

Design + Seismic
FY
1257
1510
1352

FZ
676
613
709

MX
1214
978
1829

MY

MZ

0
734
659

0
1046
665

0
561
426

0
763
645

Design +X Wind + Seismic


934
1512
1390

Template No. 5-0000-0001-T2 Rev. 1

853
612
714

1439
1011
1858

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Load Case 8.
5
16400
18400

7
951
1049

Load Case 9.
5
16400
18400

4
723
840

Load Case 10.


5
16400
18400

4
605
776

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 12 of 114

Design -X Wind + Seismic


1630
1585
1320

571
617
707

962
1032
1809

0
945
841

0
1382
926

0
635
577

0
1400
943

0
777
855

0
726
681

Design +Z Wind + Seismic


1444
1767
1579

820
903
970

1117
1167
2022

Design -Z Wind + Seismic


1007
1266
1075

733
317
410

1096
763
1582

3.3 CONCLUSION
The piping stress analysis has been carried out for the piping from the nozzle N1 of
Exchangers (12-E-102/202 & 12-E-104/204) TO nozzle F2 of 12-V-102/202 after proposed
retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 13 of 114

Retrofitting Scheme for Piping

4.0 Piping loop having Document number A375-000-16-43-ADC-0044

4.1 PROPOSED RETROFITTING


Table 4.1 Suggested modifications in supports

Node
No.

Previous support

New Support

3210

---

S3-A-2-4

3300

---

S3-A-2-4

5110

---

S1-A--4

Remarks
in Z & 29.5 mm gap in +Z

in +X & without Y & -X guide

4.2 RESULTS AFTER RETROFITTING


Table 4.2 Maximum stresses for design and wind (static) load cases according to ASME ND

Load
Case
No.
4

Stresses (psi)
Actual

Allow.

% of
Allowable

SUSTAINED

21079.4

22322

94.4

DS3-DS4 (EXP)

THERMAL

53740.2

33281.4

161.5

ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

23367.7
24399
25415.5
23560.5

24749.1
24749.1
24749.1
24749.1

94.4
98.6
102.7
95.2

CAESAR Load Case

Description

W+P1+F1 (SUS)

13
18
19
20
21

Status
OK
Not
Qualified
OK
OK
Marginal
OK

Table 4.3 Maximum stresses for design and wind (static) load cases according to ASME B 31.3

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

13916.4
32186.2
27913.4
23562.8
15652
14268.1

14499.4
34622.7
26190.9
26190.9
19284.2
19284.2

96.0
93
106.6
90.0
81.2
74

Status
OK
OK
Marginal
OK
OK
OK

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 14 of 114

Retrofitting Scheme for Piping


Table 4.4 Maximum stresses for seismic (dynamic) load cases according to ASME ND

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

27051.2
23936.3
23249.2
23080.5
25673.2

24749
24749
24749
24749
24749

109.3
96.7
93.9
93.3
103.7

Marginal
OK
OK
OK
Marginal

Status

Table 4.5 Maximum stresses for seismic (dynamic) load cases according to ASME B 31.3

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)

20303
20507.6
20169.4
19571.1

19284
19284
19284
19284

105.3
106.3
104.6
101.5

W+P1+F1+WIN4+SEISMIC (OCC)

29368.5

19284

152.3

Load Case Description

Marginal
Marginal
Marginal
Marginal
Not
Qualified

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 3 (F1 NOZZLE OF COLUMN 12-V-103)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

361

199

-1

4.3

-3.7

-487.0

4 (SUS)

31

-81

-0

0.9

0.9

-0.6

5 (OPE)

431

200

-10

15.7

-8.1

-491.1

6 (OPE)

305

207

-4.9

0.5

-493.0

7 (OPE)

355

196

167

22.6

198.5

-482.2

8 (OPE)

365

201

-170

-13.7

-205.7

-488.8

MAX

431/5

207/6

-170/8

22.6/7

-205.7/8

-493.0/6

NODE: 13120 (DISCHARGE NOZZLE OF PUMP 12-P-118/218A)

3 (OPE)

450

467

560

443.6

-328.3

-527.7

4 (SUS)

-7

-245

-94

-69.9

-53.0

9.6

5 (OPE)

470

477

567

448.8

-334.5

-541.5

6 (OPE)

430

458

554

438.3

-322.1

-513.9

7 (OPE)

480

509

618

478.0

-320.8

-562.3

8 (OPE)

420

425

501

408.1

-335.7

-493.1

MAX

480/7

509/7

618/7

478.0/7

-335.7/8

-562.3/7

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 15 of 114

NODE: 12120 (DISCHARGE NOZZLE OF PUMP 12-P-118/218S)

3 (OPE)

380

406

520

397.4

1.2

-482.2

4 (SUS)

-246

-78

-57.7

-43.8

7.0

5 (OPE)

398

399

514

391.1

-7.6

-492.9

6 (OPE)

362

412

525

403.6

9.9

-471.4

7 (OPE)

517

600

704

527.7

24.7

-621.7

8 (OPE)

292

245

333

295.1

-47.8

-355.8

MAX

517/7

600/7

704/7

527.7/7

-47.8/8

-621.7/7

NODE: 8560 (DISCHARGE NOZZLE OF PUMP 12-P-127/227)

3 (OPE)

26

-100

-310

-65.0

-79.3

17.5

4 (SUS)

-48

-31

-25

-5.6

3.2

9.4

5 (OPE)

139

-147

-333

-69.6

-52.5

0.1

6 (OPE)

-104

-34

-287

-60.7

-93.2

36.8

7 (OPE)

-33

-109

-177

-40.6

-19.0

28.8

8 (OPE)

75

-99

-443

-89.5

-134.6

8.6

MAX

139/5

-147/5

-443/8

-89.5/8

-134.6/8

36.8/6

NODE: 5530 (DISCHARGE NOZZLE OF PUMP 12-P-128/228)

3 (OPE)

90

-53

120

72.4

137.3

-107.3

4 (SUS)

-30

1.1

0.4

-0.0

5 (OPE)

118

-59

148

82.9

162.4

-123.9

6 (OPE)

62

-54

126

66.1

133.9

-86.7

7 (OPE)

98

-50

129

86.9

163.2

-136.1

8 (OPE)

82

-58

124

59.0

118.0

-76.3

MAX

118/5

-59/5

148/5

86.9/7

163.2/7

-136.1/7

NODE: 4 (N6 NOZZLE OF 12-E-112A)

3 (OPE)

-631

3349

454

2400.3

528.9

2185.5

4 (SUS)

28

-286

18

-6.2

-22.7

-22.7

5 (OPE)

-564

3350

465

2408.6

490.0

2140.0

6 (OPE)

-698

3348

443

2391.9

567.8

2231.0

7 (OPE)

-634

3352

533

2471.4

380.9

2173.6

8 (OPE)

-631

3347

378

2331.6

676.2

2199.4

MAX

-698/6

3352/7

533/7

2471.4/7

676.2/8

2231.0/6

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 16 of 114

NODE: 42 (DISCHARGE NOZZLE OF PUMP 12-P-119/219S)

3 (OPE)

146

281

167

66.7

495.2

-49.3

4 (SUS)

-164

-113

-269

-232.6

-87.4

99.2

5 (OPE)

216

323

146

84.6

450.1

-78.3

6 (OPE)

121

248

164

62.8

502.6

-24.3

7 (OPE)

147

299

208

89.7

511.7

-61.2

8 (OPE)

176

285

109

53.1

450.1

-45.0

MAX

216/5

323/5

-269/4

-232.6/4

511.7/7

99.2/4

NODE: 2000 (DISCHARGE NOZZLE OF PUMP 12-P-119/219A)

3 (OPE)

198

195

543

272.0

426.8

-172.8

4 (SUS)

-72

-200

-41

-27.3

24.3

68.3

5 (OPE)

237

199

520

272.7

400.0

-183.1

6 (OPE)

147

108

462

218.2

402.7

-104.4

7 (OPE)

196

218

586

294.6

446.5

-185.8

8 (OPE)

192

134

443

226.4

375.1

-123.0

MAX

237/5

218/7

586/7

294.6/7

446.5/7

-185.8/7

NODE: 1 (F NOZZLE OF COLUMN 12-C-108)

3 (OPE)

-260

3424

-139

2890.6

432.5

1391.7

4 (SUS)

-170

2251

-108

1965.3

201.8

996.1

5 (OPE)

198

3270

-152

2769.1

165.6

1788.7

6 (OPE)

-719

3605

-128

3034.0

710.2

1007.6

7 (OPE)

-275

3318

249

2430.5

165.1

1312.4

8 (OPE)

-247

3559

-529

3375.2

704.6

1483.0

MAX

-719/6

3605/6

-529/8

3375.2/8

710.2/6

1788.7/5

NODE: 2 (N6 NOZZLE OF 12-E-116A)

3 (OPE)

27

76

24

81.9

-29.6

-4.3

4 (SUS)

-3

-47

0.1

3.1

0.7

5 (OPE)

64

78

28

84.7

-52.1

-15.4

6 (OPE)

-14

75

21

79.6

-3.8

6.1

7 (OPE)

29

74

46

89.7

-34.1

-6.5

8 (OPE)

24

78

74.2

-25.2

-2.1

MAX

64/5

78/8

46/7

89.7/7

-52.1/5

-15.4/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 17 of 114

SEISMIC CASES (DYNAMIC)

Load Case 1.
NODE
42
2000
1
2
5530
8560
3
4
13120
12120

FX
303
356
685
42
183
124
409
865
635
553

Load Case 2.
42
2000
1
2
5530
8560
3
4
13120
12120

373
396
622
79
211
237
480
798
655
571

Load Case 3.
42
2000
1
2
5530
8560
3
4
13120
12120

278
306
1144
29
155
202
354
932
615
536

Design + Seismic
FY
593
435
3953
81
93
145
226
4006
740
706

FZ
412
884
514
43
205
446
26
672
829
889

MX
253
480
3508
88
97
90
22
2726
639
583

MY
665
641
830
43
230
164
40
916
542
182

MZ
191
345
1716
9
148
35
523
2710
673
714

620
614
563
66
256
137
44
877
548
189

220
355
2113
20
165
17
527
2664
687
725

249
426
3651
86
91
86
22
2718
634
589

672
617
1108
17
227
178
37
955
536
191

166
277
1332
11
128
54
529
2755
659
703

276
3048
96
111
65
40
2797
673
713

681
563
48
256
104
235
768
535
206

203
1637
12
177
46
519
2698
708
853

Design +X Wind + Seismic


635
439
3798
82
99
192
227
4008
749
699

391
861
526
46
233
469
35
683
836
883

271
481
3387
91
107
95
33
2734
644
576

Design -X Wind + Seismic


560
348
4134
79
94
79
234
4005
730
712

409
803
502
39
211
423
32
662
823
894

Load Case 4. Design +Z Wind + Seismic


42
1
2
5530
8560
3
4
13120
12120

304
699
44
190
131
404
867
665
691

610
3847
79
90
154
223
4009
781
900

Template No. 5-0000-0001-T2 Rev. 1

453
623
64
213
313
193
752
887
1073

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 18 of 114

Load Case 5. Design -Z Wind + Seismic


42
1
2
5530
8560
3
4
13120
12120

333
671
39
174
173
413
864
605
466

597
4088
83
98
144
228
4004
697
545

354
903
21
209
579
195
596
770
702

240
3993
80
84
114
31
2657
604
480

620
1102
39
211
219
242
1063
550
229

187
1807
7
117
26
525
2724
638
587

4.3 CONCLUSION
The piping stress analysis has been carried out for 2CT Transfer pumps discharge to 3CT (12C-111/211) feed inlet & 2HT (12-C-110/210) feed inlet after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceeding the allowables. Hence the system may be deemed to quality the design
adequacy re-evaluation after retrofitting.

It is to be noted that the stresses in the system are marginally exceeding the allowables only at
the tee connection (Caesar Node No. 255), where the thickness of branch connection is 3.08
mm. If this tee connection is replaced with one having the thickness of the branch 4.0 mm or
more, the stresses reduce to less than allowables.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 19 of 114

5.0 Piping loop having Document number A375-000-16-43-ADC-0046

5.1 PROPOSED RETROFITTING


Table 5.1 Suggested modifications in supports

Node
No.

Previous support

New Support

7530

S4-A-5-10

S4-A-4-10

Remarks
in X, 32 mm gap in Z & without Y guide

5.2 RESULTS AFTER RETROFITTING


Table 5.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

11271.9
37530.9
22956.4
23969.3
13279.8
12139.2

23172.5
42457.1
25788.6
25788.6
25788.6
25788.6

48.6
88.4
89.0
92.9
51.5
47.1

Status
OK
OK
OK
OK
OK
OK

Table 5.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

23771.9
23588.3
22713.1
23506.0
22615.5

25789
25789
25789
25789
25789

92.2
91.5
88.1
91.1
87.7

OK
OK
OK
OK
OK

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 20 of 114

DESIGN AND WIND (STATIC)


NODE: 1 (F1 NOZZLE OF COLUMN 12-V-103)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

376

213

-1

5.2

-4.0

-527.6

4 (SUS)

-13

-86

0.9

2.4

15.1

5 (OPE)

447

213

-11

17.3

-8.3

-533.7

6 (OPE)

317

221

-6.3

0.4

-530.2

7 (OPE)

371

210

159

36.1

184.4

-523.5

8 (OPE)

381

216

-162

-25.6

-192.4

-531.4

MAX

447/5

221/6

-162/8

36.1/7

-192.4/8

-533.7/5

NODE: 13120 (DISCHARGE NOZZLE OF PUMP 12-P-118/218A)

3 (OPE)

465

420

552

406.4

-153.7

-528.9

4 (SUS)

-4

-262

-70

-52.2

-36.0

11.4

5 (OPE)

506

441

577

420.7

-185.5

-562.5

6 (OPE)

440

418

543

407.5

-122.8

-506.7

7 (OPE)

502

454

608

441.3

-175.8

-563.3

8 (OPE)

455

396

510

381.3

-158.2

-514.2

MAX

506/5

454/7

608/7

441.3/7

-185.5/5

-563.3/7

NODE: 12120 (DISCHARGE NOZZLE OF PUMP 12-P-118/218S)

3 (OPE)

443

399

528

413.6

17.4

-484.6

4 (SUS)

-6

-262

-61

-44.5

-24.8

14.4

5 (OPE)

495

431

552

436.8

-22.4

-519.6

6 (OPE)

407

392

523

404.2

58.0

-467.1

7 (OPE)

537

518

616

488.2

-23.5

-564.5

8 (OPE)

442

395

503

398.4

17.0

-484.1

MAX

537/7

518/7

616/7

488.2/7

58.0/6

-564.5/7

NODE: 8560 (DISCHARGE NOZZLE OF PUMP 12-P-127/227)

3 (OPE)

23

-65

-312

-86.1

-73.0

-11.7

4 (SUS)

-49

-35

-25

-7.2

3.4

12.9

5 (OPE)

146

-119

-341

-93.8

-40.1

-38.6

6 (OPE)

-118

18

-285

-79.3

-99.4

17.9

7 (OPE)

-13

-66

-205

-59.6

-18.6

-2.8

8 (OPE)

61

-65

-421

-113.3

-127.3

-21.2

MAX

146/5

-119/5

-421/8

-113.3/8

-127.3/8

-38.6/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 21 of 114

NODE: 5530 (DISCHARGE NOZZLE OF PUMP 12-P-128/228)

3 (OPE)

102

-45

117

78.8

142.1

-142.4

4 (SUS)

-33

1.1

0.4

-0.8

5 (OPE)

141

-54

152

95.9

173.7

-169.3

6 (OPE)

62

-36

112

63.4

126.3

-103.0

7 (OPE)

95

-27

155

96.7

167.0

-160.3

8 (OPE)

109

-65

83

61.2

118.9

-122.7

MAX

141/5

-65/8

155/7

96.7/7

173.7/5

-169.3/5

NODE: 2 (N6 NOZZLE OF 12-E-112A)

3 (OPE)

-320

199

33

98.1

172.3

-168.0

4 (SUS)

-20

-226

11

7.9

6.0

33.2

5 (OPE)

-224

215

45

121.6

143.3

-194.6

6 (OPE)

-407

182

21

78.6

195.3

-143.1

7 (OPE)

-320

172

133

176.9

186.7

-180.2

8 (OPE)

-306

221

-57

37.5

141.8

-160.6

MAX

-407/6

-226/4

133/7

176.9/7

195.3/6

-194.6/5

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

FZ

MX

MY

5530
8560
1
13120
12120
2

165
136
424
622
614
458

84
111
240
692
566
274

187
439
32
872
790
144

104
118
22
577
525
245

202
147
56
498
443
257

182
40
562
716
614
261

234
114
60
530
448
228

209
67
569
749
649
288

186
174
52
467
484
280

142
46
565
694
596
237

Load Case 2.

Design +X Wind + Seismic

5530
8560
1
13120
12120
2

93
164
240
713
598
291

204
259
495
663
666
363

223
468
42
897
814
156

122
125
35
591
548
269

Load Case 3.

Design -X Wind + Seismic

5530
8560
1
13120
12120
2

75
63
247
691
559
257

124
231
365
596
579
546

Template No. 5-0000-0001-T2 Rev. 1

182
413
39
863
785
132

89
111
24
578
516
226

MZ

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


Load Case 4.
5530
8560
1
13120
12120
2

157
126
419
659
708
459

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 22 of 114

Design +Z Wind + Seismic


66
112
237
726
685
248

225
332
190
928
878
245

122
91
53
612
600
324

227
93
236
520
449
271

200
31
558
750
694
274

87
145
43
552
510
185

179
201
244
503
443
226

162
49
566
701
613
254

Load Case 5. Design -Z Wind + Seismic


5530
8560
1
13120
12120
2

172
175
429
612
613
445

103
110
243
669
563
297

153
548
193
830
765
168

5.3 CONCLUSION

The piping stress analysis has been carried out for XU-I product transfer to XU-II after proposed
retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceeding the allowable stresses. Hence the system may be deemed to qualify the
design adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 23 of 114

6.0 Piping loop having Document number A375-000-16-43-ADC-0049

6.1 PROPOSED RETROFITTING


Table 6.1 Suggested modifications in supports

Remarks

Node
No.

Previous support

New Support

1510

S4-A-2-10

S4-A-4-10

in Z, 0 mm gap in X & without Y guide

500

L1A-2-

L8A-2- -S

With 9 mm gap

430

S4-A-2-10

S4-A-4-10

390

L6-2-1950

L8-2-1950-T

1210

S1-A-2

S1-A-1

1270

S1-A-1

S1-A-4

without Z guide, With 8 mm gap in X & 7


mm gap in -Y
With 14.5 mm gap in Z, 8 mm gap in X &
without Y guide
With 48 mm gap in Z, 0 mm gap in X &
without Y guide

6.2 RESULTS AFTER RETROFITTING


Table 6.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

15541.7
36734.5
17225.2
16093.4
16534.1
16417.3

25650.0
33481.9
30780.0
30780.0
30780.0
30780.0

60.6
109.7
56.0
52.3
53.7
66.3

OK
Marginal
OK
OK
OK
OK

Table 6.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Template No. 5-0000-0001-T2 Rev. 1

Actual

Allow.

% OF
Allowable

Status

25806.9
26300.0
23724.6
24407.4
25766.5

24749
24749
24749
24749
24749

104.3
106.3
95.9
98.6
104.1

Marginal
Marginal
OK
OK
Marginal

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 24 of 114

Retrofitting Scheme for Piping

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (1ST STAGE HOT TOWER 12-C-107 F1 NOZZLE)
CASE TYPE

FX

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

-201
-28
415
-820
-203
-201
-820/6

FY

FZ

MX

MY

MZ

3191
-61
3065
3363
3016
3396
3396/8

-124
-25
-130
-119
391
-640
-640/8

3853.0
28.1
3716.1
4045.6
2730.8
5011.1
5011.1/8

334.4
69.7
-291.8
972.2
78.7
595.7
972.2/6

951.9
134.0
1898.6
17.3
886.4
1025.2
1898.6/5

-4
-2
-8
-4
42
-57
-57/8

-1.7
0.2
-7.9
-2.5
37.4
-49.6
-49.6/8

-2.8
7.7
-15.6
-3.5
64.6
-89.1
-89.1/8

31.1
203.8
-4.9
39.9
21.2
18.7
203.8/4

-110.3
-9.4
-92.1
-116.6
5.1
-246.5
-246.5/8

171.9
-4.8
186.1
162.7
257.8
57.9
257.8/7

-211.6
0.7
-229.7
-187.1
-159.9
-278.3
-278.3/8

-465.4
2.4
-421.8
-496.5
-412.3
-483.4
-496.5/6

-306.3
-1.1
-270.2
-333.5
-262.2
-332.0
-333.5/6

40.9
9.3
40.8
47.8
53.9
47.6
53.9/7

NODE: 1480 (12-V-104/204 F1 NOZZLE)

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

-259
-414
-185
-294
-238
-233
-414/4

1
-140
19
9
6
5
-140/4

NODE: 890 (PUMP 117A DISCHARGE NOZZLE)


3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

344
11
365
317
333
350
365/5

-170
-186
-188
-161
-247
-83
-247/7

-380
-22
-368
-378
-205
-602
-602/8

NODE: 100 (PUMP 117S DISCHARGE NOZZLE)


3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

97
2
115
77
105
76
115/5

211
-192
180
234
179
219
234/6

-632
-6
-571
-672
-549
-665
-672/6

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

FZ

MX

MY

171
445
709
353

268
260
4162
56

763
613
617
40

548
244
5690
37

369
311
1003
46

100
890
1
1480

Template No. 5-0000-0001-T2 Rev. 1

MZ
107
302
1838
88

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Load Case 2.
100
890
1
1480

189
466
922
280

Load Case 3.
100
890
1
1480

151
418
1327
389

Load Case 4.
100
890
1
1480

178
434
710
333

Load Case 5.
100
890
1
1480

150
451
709
328

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 25 of 114

Design +X Wind + Seismic


237
278
4037
74

703
601
623
44

505
226
5553
43

333
325
960
59

106
320
2784
62

397
302
1640
46

113
278
903
97

325
397
747
108

120
250
1772
78

395
197
1264
132

113
369
1911
76

Design -X Wind + Seismic


291
251
4335
64

804
610
612
40

579
251
5882
38

Design +Z Wind + Seismic


236
337
3988
61

681
437
885
78

495
139
4568
73

Design -Z Wind + Seismic


276
173
4367
60

796
834
1133
93

566
381
6848
85

6.3 CONCLUSION

The piping stress analysis has been carried out for piping from 2nd Stage Hot Tower Discharge
Pump 12-P-117/217 to Dump Tank (12-V-104/204) & 1st Stage Hot Tower (12-C-107/207) after
proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases marginally
exceed the allowable stresses. Hence the system may be deemed to qualify the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 26 of 114

Retrofitting Scheme for Piping

7.0 Piping loop having Document number A375-000-16-43-ADC-0051

7.1 PROPOSED RETROFITTING


Table 7.1 Suggested modifications in supports

Remarks

Node
No.

Previous support

New Support

4070

S3-A-2-4

S3-A-4-4

in +Z, 20 mm gap in Z, without Y guide &


with 12 mm gap in X

5110

---

S1-A--4

in X & without Y guide

7.2 RESULTS AFTER RETROFITTING


Table 7.2 Maximum stresses for design and wind (static) load cases according to ASME ND

Stresses (psi)

Load
Case
No.

CAESAR Load Case

Description

W+P1+F1 (SUS)

13

Actual

Allow.

% of
Allowable

SUSTAINED

24624

22322

110.3

DS3-DS4 (EXP)

THERMAL

19348.3

28309.8

68.3

18

ST4+ST14 (OCC)

+X WIND+SEISMIC

27637.8

24749.1

111.7

19

ST4+ST15 (OCC)

-X WIND+SEISMIC

27520.6

24749.1

111.2

20

ST4+ST16 (OCC)

+Z WIND+SEISMIC

34310.2

24749.1

138.6

21

ST4+ST17 (OCC)

-Z WIND+SEISMIC

32619.5

24749.1

131.8

Status
Not
Qualified
OK
Not
Qualified
Not
Qualified
Not
Qualified
Not
Qualified

Table 7.3 Maximum stresses for design and wind (static) load cases according to ASME B 31.3

Stresses (psi)

Load
Case
No.

CAESAR Load Case

Description

4
13
18
19
20
21

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Template No. 5-0000-0001-T2 Rev. 1

Actual

Allow.

% of
Allowable

Status

14629.0
16739.0
26791.7
22811.2
18410.6
18089.3

14499.4
26736.7
26190.9
26190.9
19284.2
19284.2

100.9
62.6
102.3
87.1
95.5
93.8

marginal
OK
marginal
OK
OK
OK

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 27 of 114

Retrofitting Scheme for Piping

Table 7.4 Maximum stresses for design and wind (static) load cases according to ASME ND

Load
Case
No.

Stresses (psi)
Load Case Description

Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

46777.8

24749

189.0

W+P1+F1+WIN1+SEISMIC (OCC)

50579.7

24749

204.4

W+P1+F1+WIN2+SEISMIC (OCC)

45956.5

24749

185.7

W+P1+F1+WIN3+SEISMIC (OCC)

42277.1

24749

170.8

10

W+P1+F1+WIN4+SEISMIC (OCC)

41601.3

24749

168.1

Status
Not
Qualified
Not
Qualified
Not
Qualified
Not
Qualified
Not
Qualified

Table 7.5 Maximum stresses for design and wind (static) load cases according to ASME B 31.3

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

22808.6

19284

118.3

W+P1+F1+WIN1+SEISMIC (OCC)

34394.3

19284

178.4

W+P1+F1+WIN2+SEISMIC (OCC)

32478.5

19284

168.4

W+P1+F1+WIN3+SEISMIC (OCC)

32522.5

26191

124.2

10

W+P1+F1+WIN4+SEISMIC (OCC)

34508.3

26191

131.8

Load Case Description

Status
Marginal
Not
Qualified
Not
Qualified
Not
Qualified
Not
Qualified

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

DESIGN AND WIND (STATIC)


NODE: 1 (F NOZZLE OF COLUMN 12-C-108)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-268

3495

-148

2972.0

313.7

1407.3

4 (SUS)

-173

2270

-108

1980.6

197.4

999.4

5 (OPE)

177

3539

-169

3018.5

58.8

1878.4

6 (OPE)

-727

3674

-136

3113.7

586.3

1020.8

7 (OPE)

-293

3545

232

2649.6

27.6

1384.2

8 (OPE)

-265

3799

-542

3592.8

632.2

1565.0

MAX

-727/6

3799/8

-542/8

3592.8/8

632.2/8

1878.4/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 28 of 114

NODE: 1000 (DISCHARGE NOZZLE OF PUMP 12-P-119/219S)

3 (OPE)

57

87

88

-44.7

570.2

72.1

4 (SUS)

-189

-142

-223

-221.2

-92.1

118.1

5 (OPE)

105

112

79

-35.4

544.3

44.3

6 (OPE)

-18

42

99

-66.5

610.7

113.1

7 (OPE)

52

90

121

-23.7

586.0

71.5

8 (OPE)

87

104

49

-55.3

535.7

61.2

MAX

-189/4

-142/4

-223/4

-221.2/4

610.7/6

118.1/4

NODE: 2000 (DISCHARGE NOZZLE OF PUMP 12-P-119/219A

3 (OPE)

150

222

582

272.3

547.1

-179.2

4 (SUS)

-32

-184

-44

-49.0

-25.7

22.0

5 (OPE)

195

235

570

280.7

522.2

-198.5

6 (OPE)

82

194

595

253.3

583.3

-150.4

7 (OPE)

119

237

655

295.5

599.1

-190.4

8 (OPE)

172

190

492

242.0

485.1

-150.1

MAX

195/5

237/7

655/7

295.5/7

599.1/7

-198.5/5

NODE: 8560 (DISCHARGE NOZZLE OF PUMP 12-P-127/227)

3 (OPE)

-40

-352

-95.9

-107.4

-9.4

4 (SUS)

-46

-40

-41

-10.7

-5.1

12.4

5 (OPE)

114

-102

-328

-91.2

-35.4

-31.9

6 (OPE)

-76

-341

-93.0

-137.5

8.1

7 (OPE)

-30

-42

-260

-73.3

-59.7

-0.1

8 (OPE)

34

-45

-451

-120.5

-150.3

-15.7

MAX

114/5

-102/5

-451/8

-120.5/8

-150.3/8

-31.9/5

NODE: 5530 (DISCHARGE NOZZLE OF PUMP 12-P-128/228)

3 (OPE)

124

-201

135

24.9

138.9

-28.0

4 (SUS)

-34

-3

-3.2

-1.0

-1.5

5 (OPE)

128

-198

177

35.2

156.9

-31.6

6 (OPE)

110

-199

113

19.6

131.2

-24.7

7 (OPE)

110

-211

165

32.5

158.4

-26.8

8 (OPE)

136

-179

116

20.3

123.6

-32.7

MAX

136/8

-211/7

177/5

35.2/5

158.4/7

-32.7/8

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 29 of 114

NODE: 2 (F1 NOZZLE OF 12-V-104)

3 (OPE)

363

203

0.1

-4.7

-506.3

4 (SUS)

-13

-82

-0

0.1

0.9

16.0

5 (OPE)

428

198

-13

21.4

-8.6

-503.7

6 (OPE)

298

207

-10.7

-0.4

-505.1

7 (OPE)

358

200

162

27.0

187.9

-501.7

8 (OPE)

366

204

-160

-26.4

-197.1

-506.8

MAX

428/5

207/6

162/7

27.0/7

-197.1/8

-506.8/8

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

5530
8560
2
1000
2000
1

FX
213
112
407
559
348
695

Load Case 2.
5530
8560
2
1000
2000
1

217
219
472
607
394
604

Load Case 3.
8560
5530
2
1000
2000
1

180
199
341
520
281
1154

244
81
229
487
470
4048

FZ
230
469
28
310
1047
527

MX
48
125
14
416
502
3595

MY

MZ

214
178
51
799
883
733

51
36
540
323
348
1727

232
106
55
773
858
478

54
58
538
296
368
2198

Design +X Wind + Seismic


240
143
224
512
483
4093

271
446
40
301
1035
548

58
120
35
407
511
3641

Design -X Wind + Seismic


49
242
233
443
442
4227

459
208
36
322
1060
516

122
43
25
438
483
3737

208
206
47
840
919
1006

34
47
539
364
320
1341

56
103
41
395
526
3273

234
130
234
815
935
447

49
26
536
323
360
1704

Load Case 4. Design +Z Wind + Seismic


5530
8560
2
1000
2000
1

200
134
402
554
318
721

253
84
226
491
485
4099

Template No. 5-0000-0001-T2 Rev. 1

260
378
189
343
1120
612

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 30 of 114

Load Case 5. Design -Z Wind + Seismic


5530
8560
2
1000
2000
1

226
138
410
589
371
693

222
87
230
504
438
4352

211
568
187
271
957
922

44
150
40
427
472
4216

199
221
244
765
821
1052

55
42
541
313
319
1885

7.3 CONCLUSION

The piping stress analysis has been carried out for 2nd Stage Liquid re-dump line to 2HT (12-C108) after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceeding the allowables. Hence the system may be deemed to quality the design
adequacy re-evaluation after retrofitting.

It is to be noted that the stresses in the system are marginally exceeding the allowables only at
the tee connection (Caesar Node No. 255), where the thickness of branch connection is 3.08
mm. If this tee connection is replaced with one having the thickness of the branch 4.0 mm or
more, the stresses reduce to less than allowables.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 31 of 114

Retrofitting Scheme for Piping


8.0 Piping loop having Document number A375-000-16-43-ADC-0054

8.1 PROPOSED RETROFITTING

Table 8.1 Suggested modifications in supports

Node
No.

Previous
support

200
250

New Support

Remarks

L8A-2-715-N & L8A-2-715-S


G2-3, B39-A-938-4 & B437-1714/1200-105

Guide in Z , Cross Guide X


Guide in +X with 7.0 mm gap, Guide -X & Cross
Guide Z with 3.0 mm gap

418
420
422
424
460
490
535

L8A-2-715-N
G2-3, B39-A938-4 & B43-71714/1200-105
ON RACK
ON RACK
ON RACK
ON RACK
S3-A-5-4
L5-2-1950
L6-1-1800

S3-A-2-4
S3-A-2-4
S3-A-2-4
S3-A-1-4
S3-A-5-4 & S3-A-2-4
L8A-2-1950-S
L7A-1-1800-S

Guide in X
Guide in X
Guide in X

600

L6-1-1800

L7A-1-1800-S

3040

B39-A-325-4 & S3-A-2-4

3110
3180

B39-A-325-4 &
H6-1558-3
L1A-2-375
S3-A-5-4

3220
3230
3240
3250
3475

ON RACK
ON RACK
ON RACK
ON RACK
SH-55, 2 nos

S3-A-2-4
S3-A-5-4
S3-A-2-4
S3-A-1-4
SH-55, 1 no.

L8A-2-1950-S
S3-A-5-4 & S3-A-2-4

Guide in Z , Cross Guide X


Guide in Z ,
Guide in Z with 8.0 mm gap, Guide in -X , Guide
+X with 17.0 mm gap
Guide in +Z , Guide -Z with 4.5 mm gap, Guide in
-X with 20.0 mm gap, Guide +X
Guide in Z with 5.0 mm gap
Guide in +Z with 5.0 mm gap, Guide -Z
Guide in +Z , Guide -Z with 22.0 mm gap &
Cross Guide X
Guide X
Cross Guide Z with 3.0 mm gap
Guide X

8.2 RESULTS AFTER RETROFITTING

Table 8.2 Maximum stresses for design and wind (static) load cases

Stresses (psi)

Load
Case
No.

CAESAR Load Case

Description

W+P1+F1 (SUS)

17

Actual

Allow.

% of
Allowable

SUSTAINED

17,127

22,808

75.0

DS3-DS4 (EXP)

THERMAL

27,788

30,823

90.0

OK
OK

18

ST4+ST13 (OCC)

+X WIND+ SUS

24,464

24,749

99.0

OK

19

ST4+ST14 (OCC)

-X WIND+ SUS

24,463

24,749

99.0

OK

20

ST4+ST15 (OCC)

+Z WIND+ SUS

22,504

24,749

91.0

OK

21

ST4+ST16 (OCC)

-Z WIND+ SUS

23,669

24,749

96.0

OK

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Status

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 32 of 114

Retrofitting Scheme for Piping


Table 8.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Load Case Description

Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

21,134

25,343

83.0

W+P1+F1+WIN1+SEISMIC (OCC)

32,508

24,749

131.0

W+P1+F1+WIN2+SEISMIC (OCC)

32,593

24,749

132.0

W+P1+F1+WIN3+SEISMIC (OCC)

26,700

24,749

108.0

10

W+P1+F1+WIN4+SEISMIC (OCC)

28,062

24,749

113.0

Status
OK
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED

The actual loading obtained on the nozzles of connecting equipments by the piping analysis is
given below. The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 2 (3RD STAGE COLD TOWER NOZZLE R)
NODE

Load case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

3 (OPE)

-3

146

150.6

-30.8

-12.5

4 (SUS)

-0

-33

17.3

-1.5

-0.4

5 (OPE)

153

151

154.1

-157.8

72.3

6 (OPE)

-159

145

150.0

98.8

-96.5

7 (OPE)

-3

144

132

84.7

-20.4

-9.3

8 (OPE)

-2

162

-126

228.2

-22.7

-8.9

MAX

-159/6

162/8

132/7

228.2/8

-157.8/5

-96.5/6

NODE: 11 (PUMP 12-P-124/224A DISCHARGE)


11

3 (OPE)

67

36

-0.9

-5.0

-29.1

4 (SUS)

-13

-5

-2.6

-1.4

-0.8

5 (OPE)

90

-11

103

11.4

-26.1

-38.1

6 (OPE)

-24

-41

-6.5

15.4

10.3

7 (OPE)

60

-3

88

13.5

6.7

-27.2

8 (OPE)

45

-18

-26

-17.7

-17.5

-17.4

MAX

90/5

-41/6

103/5

-17.7/8

-26.1/5

-38.1/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 33 of 114

Retrofitting Scheme for Piping


NODE: 801 (PUMP 12-P-124/224S DISCHARGE)
801

3 (OPE)

61

21

27

-2.0

-0.1

-27.3

4 (SUS)

-13

-5

-2.6

-1.4

-0.9

5 (OPE)

83

-4

70

6.4

-24.4

-34.2

6 (OPE)

-18

-3

21

-3.7

23.1

5.1

7 (OPE)

47

15

99

16.3

16.3

-22.7

8 (OPE)

46

-25

-16.9

-10.2

-19.0

MAX

83/5

21/3

99/7

-16.9/8

-24.4/5

-34.2/5

NODE: 11600 (EXCHANGER 12-E-123/223_N1)


11600

3 (OPE)

-26

-135

47

71.8

-6.2

46.7

4 (SUS)

44

-1.2

1.1

-1.6

5 (OPE)

-95

-145

48

71.6

-39.7

15.0

6 (OPE)

49

-123

45

71.9

31.8

81.3

7 (OPE)

-30

-135

23

80.4

-4.7

44.1

8 (OPE)

-29

-169

100

57.3

10.5

47.5

MAX

-95/5

-169/8

100/8

80.4/7

-39.7/5

81.3/6

NODE: 11700 (EXCHANGER 12-E-123/223_N2)


11700

3 (OPE)

-80

-93

32

134.1

-82.2

49.0

4 (SUS)

-0

50

-0.4

-0.7

-3.5

5 (OPE)

-141

-95

27

133.4

-119.2

80.4

6 (OPE)

-15

-92

38

135.0

-40.6

16.9

7 (OPE)

-85

-94

-21

113.1

-93.8

51.0

8 (OPE)

-75

-103

95

161.6

-58.5

48.7

MAX

-141/5

-103/8

95/8

161.6/8

-119.2/5

80.4/5

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
2
11
801
11600
11700

FX
110
94
87
35
108

Design + Seismic
FY
344
27
40
148
99

Template No. 5-0000-0001-T2 Rev. 1

FZ

MX
71
68
64
58
49

MY
296
7
9
77
143

MZ
105
19
19
12
113

39
42
39
54
61

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


Load Case 7.

Design +X Wind + Seismic

2
11
801
11600
11700

348
36
23
157
101

260
116
109
103
169

Load Case 8.
2
11
801
11600
11700

266
50
43
58
43

71
136
107
59
45

299
17
13
77
142

343
67
22
135
98

71
41
58
56
56

295
12
11
77
144

Design +Z Wind + Seismic

2
11
801
11600
11700

343
67
22
135
98

Load Case 10.


2
11
801
11600
11700

109
72
72
37
103

99
51
46
23
93

Design -X Wind + Seismic

Load Case 9.
266
50
43
58
43

232
41
43
46
150

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 34 of 114

71
41
58
56
56

295
12
11
77
144

173
30
42
38
71

123
23
17
89
29

173
30
42
38
71

123
23
17
89
29

Design -Z Wind + Seismic


360
44
23
182
108

194
58
61
111
113

373
24
24
63
170

97
32
29
17
89

36
30
31
55
61

8.3 CONCLUSION

The piping stress analysis has been carried out for the piping from Pumps (12-P-124/224A/S)
discharge to nozzle N2 of Exchanger(12-E-123/223) and nozzle N1 of Exchanger (12-E123/223) to nozzle R of 3rd Stage Cold Tower (12-C-111/211) after proposed retrofitting
modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 35 of 114

9.0 Piping loop having Document number A375-000-16-43-ADC-0056

9.1 PROPOSED RETROFITTING

Table 9.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

4050
4180
1040
4070
4220
350

S1-A-1
S1-A-1
S1-A-1
S1-A-1
S1-A-1
S1-A-1

S1-A-2
S1-A-2
S1-A-2
S1-A-2
S1-A-2
S1-A-5

With 6 mm gap

9.2 RESULTS AFTER RETROFITTING

Table 9.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

18432.8
22519.1
23871.7
26934.7
20897.5
20408.9

23172.5
24737.1
24749.1
30780.0
25788.6
25788.6

% of
Allowable
79.5
91.0
96.5
87.5
81.0
79.1

Statu
s
OK
OK
OK
OK
OK
OK

Table 9.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

25917.0

25789

100

W+P1+F1+WIN1+SEISMIC (OCC)

29170.3

24749

117.9

W+P1+F1+WIN2+SEISMIC (OCC)

27934.3

24749

112.9

9
10

W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

25645.9
26198.8

25789
25789

99.4
101.6

Load Case Description

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Status
OK
Not
Qualified
Not
Qualified
OK
Marginal

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 36 of 114

Retrofitting Scheme for Piping

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1220 (N6 NOZZLE OF EXCHANGER 12-E-117/217A)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-107

652

164

574.6

3.9

126.1

4 (SUS)

-13

-107

1.3

6.0

4.5

5 (OPE)

-77

649

175

582.0

-18.0

108.9

6 (OPE)

-132

662

156

573.6

21.1

134.9

7 (OPE)

-102

661

225

606.0

-39.1

127.8

8 (OPE)

-93

648

107

538.1

32.6

127.2

MAX

-132/6

662/6

225/7

606.0/7

-39.1/7

134.9/6

NODE: 3 (DISCHARGE NOZZLE OF PUMP 12-P-123/223A)

3 (OPE)

158

-225

289

70.9

-14.6

-73.7

4 (SUS)

-58

-5

-2.7

-0.9

0.0

5 (OPE)

171

-226

298

72.1

-14.8

-81.2

6 (OPE)

145

-216

302

73.1

-7.0

-70.0

7 (OPE)

166

-253

313

81.5

-8.3

-66.5

8 (OPE)

150

-198

264

59.9

-21.2

-81.0

MAX

171/5

-253/7

313/7

81.5/7

-21.2/8

-81.2/5

NODE: 4 (DISCHARGE NOZZLE OF PUMP 12-P-123/223S)

3 (OPE)

110

-282

35

33.8

-58.5

18.2

4 (SUS)

-57

-4

-2.2

-0.7

0.2

5 (OPE)

102

-285

47

36.3

-60.0

15.9

6 (OPE)

118

-262

32

30.3

-53.2

14.6

7 (OPE)

135

-278

96

47.6

-42.0

11.7

8 (OPE)

90

-269

-28

16.4

-75.1

18.1

MAX

135/7

-285/5

96/7

47.6/7

-75.1/8

18.2/3

NODE: 1 (F1 NOZZLE OF 12-V-105)

3 (OPE)

-17

-211

-4

14.8

28.3

217.0

4 (SUS)

-160

-325

-2

-31.1

16.6

456.7

5 (OPE)

85

-180

-8

18.4

15.6

143.2

6 (OPE)

-106

-247

-1

9.6

40.9

316.9

7 (OPE)

-7

-215

153

49.9

304.6

239.6

8 (OPE)

-14

-212

-157

-46.0

-239.5

219.4

MAX

-160/4

-325/4

-157/8

49.9/7

304.6/7

456.7/4

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 37 of 114

SEISMIC CASES (DYNAMIC)

Load Case 1.
NODE
1
3
4
1220

FX

FY

56
236
157
142

Load Case 2.
1
3
4
1220

124
250
148
113

Load Case 3.
1
3
4
1220

Design + Seismic

146
224
164
167

FZ
250
288
319
738

MX
59
370
137
209

MY
32
91
56
625

MZ
217
43
87
51

314
99
32
179

204
43
89
65

240
107
30
162

27
93
52
624

229
35
82
68

414
96
29
188

67
102
69
656

493
37
71
86

336
92
26
181

63
80
38
588

428
50
104
79

316
107
32
180

Design +X Wind + Seismic


220
288
323
734

62
379
149
220

36
92
58
632

Design -X Wind + Seismic


287
278
299
748

56
383
133
201

Load Case 4. Design +Z Wind + Seismic


1
3
4
1220

47
245
181
137

254
315
316
746

208
394
197
270

Load Case 5. Design -Z Wind + Seismic


1
3
4
1220

54
228
136
128

252
260
307
734

211
346
130
152

9.3 CONCLUSION

The piping stress analysis has been carried out from pump 12-P-123/223

to 12-E-119/219

after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 38 of 114

Retrofitting Scheme for Piping

10.0

Piping loop having Document number A375-000-16-43-ADC-0059

10.1

NODE

PREVIOUS

PROPOSED RETROFITTING

NEW SUPPORT

REMARKS

SUPPORT
260

S3-A-5-3

S3-A-5-3 & S3-A-2-3

Guide in +Z with 52.0 mm gap, Guide -Z

300

S3-A-1-3

S3-A-5-3 & S3-A-2-3

Guide in +X with 7.0 mm gap, Guide -X & Cross Guide Z with 3.0
mm gap

320

On rack

S3-A-1-3

330

On rack

S3-A-2-3

Guide in +X with 16.0 mm gap, Guide -X

332

On rack

S3-A-5-3 & S3-A-2-3

Guide in X , Cross Guide Z

334

On rack

S3-A-2-3

Guide in -X with 34.0 mm gap, Guide +X

350

S3-A-1-3

S3-A-2-3

Guide in +Z with 11.0 mm gap, Guide -Z

360

S3-A-2-3

S3-A-2-3 & S3-A-5-3

Guide in X

485

SH-260

SH-260 & S3-C-2-3

Guide in Z with 1.5 mm gap,

1030

S3-A-1

S3-A-2 & S3-A-5

Guide in +Z with 8.0 mm gap, Guide -Z


Cross Guide in -X with 4.0 mm gap, Guide +X

1070

S3-A-1

S3-A-2

Guide in +Z , Guide -Z with 2.5 mm gap

1085

S3-A-2

Guide in -X with 11.5 mm gap, Guide +X , +Y with 10.0 mm gap

1200

L7A-2-H-S

Guide in X , Guide in Z

1245

SH-49

&

Springs to be removed

&

S3-A-1 & B2-468-4

Guide in X , Guide in Z

SH-50
1315

S3-A-1
B3-468-4

10.2 SPRING DETAILS:


SPRING

NO.

OF

HOT LOAD

COLD LOAD

SPRINGS

VERTICAL

SPRING RATE

MOVMENT

USED

GIVEN

GIVEN

GIVEN

GIVEN

SH-48

176

180

+1.0

40

SH-49

880

896

+1.0

160(to be removed)

SH-50

880

896

+1.0

160(to be removed)

SH-52

194

175

-11.0

17.273

SH-260*

256

275

+4.0

47.5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 39 of 114

Retrofitting Scheme for Piping


Table 10.1

Load
Case
No.
4

Maximum stresses for design and wind (static) load cases according to ASME ND

Stresses (psi)
Actual

Allow.

% of
Allowable

SUSTAINED

18,346

22,322

82.0

DS3-DS4 (EXP)

THERMAL

22,095

28,472

78.0

OK
OK

18

ST4+ST13 (OCC)

+X WIND+ SUS

24,986

101.0

MARGINAL

19

ST4+ST14 (OCC)

-X WIND+ SUS

26,259

24,749
24,749

106.0

MARGINAL

20

ST4+ST15 (OCC)

+Z WIND+ SUS

27,155

24,749

110.0

MARGINAL

21

ST4+ST16 (OCC)

-Z WIND+ SUS

27,442

24,749

111.0

MARGINAL

CAESAR Load Case

Description

W+P1+F1 (SUS)

17

Table 10.2

Status

Maximum stresses for seismic (dynamic) load cases according to ASME ND

Load
Case
No.

Stresses (psi)
Load Case Description

Actual

W+P1+F1+SEISMIC (OCC)

24,604

W+P1+F1+WIN1+SEISMIC (OCC)

30,105

W+P1+F1+WIN2+SEISMIC (OCC)

25,784

W+P1+F1+WIN3+SEISMIC (OCC)

29,445

10

W+P1+F1+WIN4+SEISMIC (OCC)

28,832

Allow.
24,749
24,749

% OF
Allowable

Status

99.0

OK
NOT

122.0
24,749

104.0

QUALIFIED
MARGINAL

24,749

NOT
119.0

QUALIFIED
NOT

24,749

117.0

QUALIFIED

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 11 (PUMP 12-P-122/222A DISCHARGE)

NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

11

3 (OPE)

53

-25

31

4.1

6.6

-13.2

4 (SUS)

-18

-0.1

-0.1

-0.6

5 (OPE)

101

-18

48

8.1

3.1

-31.4

6 (OPE)

-6

-21

18

1.8

8.0

9.4

7 (OPE)

54

-23

95

23.1

22.9

-14.6

8 (OPE)

35

-35

-37

-15.9

-9.6

-4.3

MAX

101/5

-35/8

95/7

23.1/7

22.9/7

-31.4/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 40 of 114

Retrofitting Scheme for Piping


NODE: 701 (PUMP 12-P-122/22S DISCHARGE)

701

3 (OPE)

89

18.7

32.8

4.4

4 (SUS)

-0

-18

0.1

0.1

0.2

5 (OPE)

50

11

94

19.9

26.9

-11.9

6 (OPE)

-35

21

82

17.5

35.5

18.6

7 (OPE)

12

14

212

49.8

64.3

-0.3

8 (OPE)

12

-26

-11.1

3.7

3.7

MAX

50/5

21/6

212/7

49.8/7

64.3/7

18.6/6

NODE: 1430 (3RD STAGE HOT TOWER NOZZLE F1)

1430

3 (OPE)

-38

221

-5

193.2

30.6

-33.5

4 (SUS)

13

34.4

0.6

0.2

5 (OPE)

69

249

-15

229.7

-59.4

-0.9

6 (OPE)

-146

194

156.8

120.5

-66.0

7 (OPE)

-47

244

80

166.7

66.2

-40.9

8 (OPE)

-30

199

-89

219.4

-4.3

-26.0

MAX

-146/6

249/5

-89/8

229.7/5

120.5/6

-66.0/6

NODE: 15500 (EXCHANGER 12-E-117/217D_N7)

15500

3 (OPE)

-342

-342

716

-47.2

146.9

-349.8

4 (SUS)

106

-9

0.3

1.8

-0.1

5 (OPE)

-701

-379

842

-113.4

-209.1

-639.3

6 (OPE)

56

-325

621

5.3

557.6

-30.2

7 (OPE)

-335

-317

506

66.6

62.5

-326.3

8 (OPE)

-336

-377

932

-162.1

260.6

-366.5

MAX

-701/5

-379/5

932/8

-162.1/8

557.6/6

-639.3/5

NODE: 16300 (EXCHANGER 12-E-118/218A_N2)

16300

3 (OPE)

-46

-1190

-162

-602.9

-51.5

779.8

4 (SUS)

-19

-294

-9

-195.1

22.3

213.8

5 (OPE)

-216

-1275

-162

-658.6

-38.4

700.8

6 (OPE)

125

-1101

-160

-547.4

-64.4

857.6

7 (OPE)

-39

-1266

-320

-633.3

-147.0

817.7

8 (OPE)

-50

-1107

-2

-570.3

47.4

746.5

MAX

-216/5

-1275/5

-320/7

-658.6/5

-147.0/7

857.6/6

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 41 of 114

Retrofitting Scheme for Piping

NODE: 16400 (EXCHANGER 12-E-118/218A_N1)

16400

3 (OPE)

102

-1313

-1138

-132.3

-208.7

83.1

4 (SUS)

153

21

5.5

11.7

25.0

5 (OPE)

-163

-1177

-1177

-119.0

51.0

-62.0

6 (OPE)

394

-1460

-1056

-177.3

-492.2

260.2

7 (OPE)

66

-1403

-1438

19.4

-184.9

89.1

8 (OPE)

172

-1277

-828

-302.0

-260.6

123.6

MAX

394/6

-1460/6

-1438/7

-302.0/8

-492.2/6

260.2/6

NODE: 17300 (EXCHANGER 12-E-118/218B_N2)

17300

3 (OPE)

115

-846

203

702.1

55.7

-239.5

4 (SUS)

94

-2.2

0.7

0.6

5 (OPE)

28

-840

215

708.7

-9.9

-191.9

6 (OPE)

209

-846

191

696.6

117.5

-285.1

7 (OPE)

129

-818

106

649.8

78.3

-234.1

8 (OPE)

108

-866

296

752.8

32.4

-242.6

MAX

209/6

-866/8

296/8

752.8/8

117.5/6

-285.1/6

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
11
701
1430
15500
16300
16400
17300

FX
84
31
59
440
80
196
137

Load Case 7.
11
701
1430
15300
16300
16400
17300

131
75
91
3858
250
257
50

Design + Seismic
FY
51
28
250
364
1266
1379
866

FZ
62
138
29
799
196
1231
226

MX
10
28
216
92
641
182
714

MY

MZ

18
48
56
249
109
321
82

27
16
40
438
852
140
254

15
42
84
2
96
163
36

46
24
8
164
773
119
207

Design +X Wind + Seismic


44
36
278
26783
1350
1244
859

Template No. 5-0000-0001-T2 Rev. 1

80
144
39
186
197
1270
238

14
30
252
42
696
168
720

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Load Case 8.
11
701
1430
15300
16300
16400
17300

37
60
167
3882
159
488
230

Load Case 9.
11
701
1430
15300
16300
16400
17300

85
36
68
3873
73
160
151

Design -X Wind + Seismic


48
46
223
27016
1177
1527
865

66
37
51
3869
84
266
130

50
131
29
198
194
1149
214

8
27
179
47
585
227
708

20
51
145
3
122
604
144

24
30
73
170
930
317
300

35
79
91
2
204
297
105

29
12
48
168
890
146
249

Design +Z Wind + Seismic


50
39
273
26877
1341
1470
837

Load Case 10.


11
701
1430
15300
16300
16400
17300

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 42 of 114

126
261
104
165
354
1531
129

29
60
189
43
671
69
661

Design -Z Wind + Seismic


61
27
228
26901
1183
1344
886

68
75
113
212
36
921
319

22
21
242
45
608
351
764

21
19
29
3
105
373
59

19
15
33
167
819
180
258

10.3 CONCLUSION
The piping stress analysis has been carried out for the piping Pumps (12-P-122/222A/S)
discharge to nozzle N1 & N2 of exchanger 12-E-118/218A/B , nozzle N7 of exchanger 12-E117A and nozzle F1 of 3rd Stage Hot

Tower (12-C-110/210) after proposed retrofitting

modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceeding the allowables. Hence the system may be deemed to quality the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 43 of 114

Retrofitting Scheme for Piping

11.0

Piping loop having Document number A375-000-16-43-ADC-0062

11.1 PROPOSED RETROFITTING

Table 11.1 Suggested modifications in supports

Node
No.

Previous support

155

B43-7-1705/525200, S3-A-1-4

140

L6-1-1495

New Support
B43-7-1705/525200, S3-A-2-4,
S3-A-5-4
L7A-1-1495-S

Remarks

Guide in Z with 15 mm gap, Guide X with 3.0 mm gap


Guide Z

11.2 RESULTS AFTER RETROFITTING

Table 11.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+ SUS
-X WIND+ SUS
+Z WIND+ SUS
-Z WIND+ SUS

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

11,134
18,888
16,550
18,349
20,024
22,343

22,322
34,469
24,749
24,749
24,749
24,749

50
55
67
74
81
90

OK
OK
OK
OK
OK
OK

Allow.

% of
Allowable

Status

Table 11.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Load Case Description

Actual

W+P1+F1+SEISMIC (SUS)

24,499

24,749

99

W+P1+F1+WIN1+SEISMIC (OCC)

28,542

24,749

115

W+P1+F1+WIN2+SEISMIC (OCC)

29,627

24,749

120

W+P1+F1+WIN3+SEISMIC (OCC)

30,833

24,749

125

10

W+P1+F1+WIN4+SEISMIC (OCC)

30,488

24,749

123

Template No. 5-0000-0001-T2 Rev. 1

OK
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 44 of 114

Retrofitting Scheme for Piping

The actual loading obtained on the nozzles of connecting equipments by the piping analysis is
given below. The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (3RD STAGE COLD TOWER NOZZLE F1)

NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

3 (OPE)

-26

294

-4

258.7

24.3

64.8

4 (SUS)

-0

-111

-0

-43.9

2.0

1.2

5 (OPE)

118

301

-7

264.7

-68.6

114.9

6 (OPE)

-167

239

-0

216.1

121.6

7.7

7 (OPE)

-30

296

116

222.3

-26.1

57.5

8 (OPE)

-22

293

-123

295.4

74.9

72.1

MAX

-167/6

301/5

-123/8

295.4/8

121.6/6

114.9/5

NODE: 24400 (EXCHANGER 12-E-120/220_N1)


24400

3 (OPE)

114

133

-29

41.6

-16.1

116.6

4 (SUS)

-24

108

-3.4

5.1

-4.5

5 (OPE)

82

129

-31

39.6

-14.9

99.1

6 (OPE)

147

131

-29

41.5

-17.6

135.8

7 (OPE)

77

132

-68

64.4

-10.8

86.4

8 (OPE)

186

117

-15

59.2

-11.2

158.9

MAX

186/8

133/3

-68/7

64.4/7

-17.6/6

158.9/8

SEISMIC CASES (DYNAMIC)


Load Case 6.

Design + Seismic

NODE

FX

FY

FZ

MX

MY

MZ

1
24400

113
156

554
147

55
45

450
71

82
38

117
156

456
69

126
36

167
139

Load Case 7.
1
24400

Design +X Wind + Seismic


206
124

561
143

Template No. 5-0000-0001-T2 Rev. 1

58
46

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 45 of 114

Retrofitting Scheme for Piping


Load Case 8.
1
24400

Design -X Wind + Seismic


254
189

Load Case 9.
1
24400

500
145

407
70

179
39

60
176

Design +Z Wind + Seismic


117
119

Load Case 10.


1
24400

51
44

556
146

167
83

413
93

84
32

110
126

Design -Z Wind + Seismic


109
228

553
131

175
30

486
88

133
33

124
199

11.3 CONCLUSION
The piping stress analysis has been carried out for the piping from nozzle N1 of Exchanger
(12-E-120/220) to nozzle F1 of 3rd Stage Cold Tower (12-C-111/211) after proposed retrofitting
modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 46 of 114

Retrofitting Scheme for Piping


12.0

Piping loop having Document number A375-000-16-43-ADC-0063

12.1 PROPOSED RETROFITTING


Table 12.1 Suggested modifications in supports (In addition to modifications specified for loop
having Document number A375-000-16-43-ADC-0065)

Node
No.

Previous support

New Support

220

S3-A-1-2

S3-A-4-2

2620
2625

S3-A-1-4
---

S3-A-2-4
S3-A-2-4

Remarks
& without
Y guide
With 12 mm gap in +X & 0 mm gap in -X

12.2 RESULTS AFTER RETROFITTING

Table 12.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

19121.5
31116.3
26397.6
24136.7
24726.8
24703.2

22808.0
29133.4
24749.1
30780.0
30780.0
30780.0

83.8
106.8
106.7
78.4
80.3
80.3

OK
Marginal
Marginal
OK
OK
OK

Status

Table 12.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

25405.3
20897.2
22353.7
23367.5
22353.8

25343.0
25343.0
24749.1
24749.1
24749.1

100.2
82.5
90.3
94.4
90.3

Marginal
OK
OK
OK
OK

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 47 of 114

Retrofitting Scheme for Piping

DESIGN AND WIND (STATIC)


NODE: 1 (DISCHARGE NOZZLE OF PUMP 12-P-129)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

119

-18

57

16.7

30.1

-40.4

4 (SUS)

18

-17

-1

-0.1

-0.1

-4.8

5 (OPE)

148

-22

57

16.6

30.1

-48.6

6 (OPE)

91

-10

56

16.3

29.8

-33.5

7 (OPE)

115

-15

57

16.4

29.5

-39.7

8 (OPE)

123

-21

58

16.8

30.7

-40.8

MAX

148/5

-22/5

58/8

16.8/8

30.7/8

-48.6/5

NODE: 2 (F1 NOZZLE OF 12-V-106)

3 (OPE)

446

183

-99

4.3

-160.6

-482.2

4 (SUS)

-26

-82

-3

-6.6

-12.1

22.2

5 (OPE)

535

199

-102

9.9

-157.9

-509.4

6 (OPE)

351

164

-96

-1.1

-162.7

-452.3

7 (OPE)

462

195

28

38.0

-10.5

-504.2

8 (OPE)

452

186

-243

-18.6

-369.1

-480.4

MAX

535/5

199/5

-243/8

38.0/7

-369.1/8

-509.4/5

NODE: 9150 (DISCHARGE NOZZLE OF PUMP 12-P-120A)

3 (OPE)

68

-119

-72

-11.6

7.0

-18.3

4 (SUS)

-1

-23

3.3

1.9

0.7

5 (OPE)

69

-119

-71

-11.4

7.6

-18.9

6 (OPE)

66

-119

-73

-11.8

6.5

-17.6

7 (OPE)

67

-119

-62

-9.7

9.7

-18.1

8 (OPE)

68

-119

-81

-13.5

4.4

-18.4

MAX

69/5

-119/6

-81/8

-13.5/8

9.7/7

-18.9/5

NODE: 3170 (DISCHARGE NOZZLE OF PUMP 12-P-120S)

3 (OPE)

113

-44

-51

-8.5

12.5

-41.5

4 (SUS)

-22

1.6

0.8

0.1

5 (OPE)

114

-44

-52

-8.6

12.5

-42.2

6 (OPE)

111

-44

-51

-8.5

12.4

-41.0

7 (OPE)

111

-47

-47

-7.5

13.1

-40.6

8 (OPE)

114

-42

-55

-9.5

12.1

-42.1

MAX

114/5

-47/7

-55/8

-9.5/8

13.1/7

-42.2/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 48 of 114

NODE: 4 (N2 NOZZLE OF EXCHANGER 12-E-116C)

3 (OPE)

193

-42

-145.2

10.8

26.5

4 (SUS)

-1

-47

-2

-0.3

-1.1

0.2

5 (OPE)

25

193

-44

-146.6

18.5

17.3

6 (OPE)

-21

193

-40

-144.6

-1.1

36.5

7 (OPE)

190

-21

-136.3

7.0

26.7

8 (OPE)

195

-63

-154.4

13.1

26.5

MAX

25/5

195/8

-63/8

-154.4/8

18.5/5

36.5/6

NODE: 18 (N7 NOZZLE OF EXCHANGER 12-E-116B)

3 (OPE)

-26

-213

-8

-57.8

21.5

-40.4

4 (SUS)

20

-205

-3

-55.9

-6.8

37.8

5 (OPE)

-14

-212

-8

-56.8

18.5

-24.6

6 (OPE)

-36

-214

-8

-59.5

23.4

-53.9

7 (OPE)

-27

-213

-2

-65.5

21.1

-42.0

8 (OPE)

-25

-213

-14

-51.4

21.6

-40.1

MAX

-36/6

-214/6

-14/8

-65.5/7

23.4/6

-53.9/6

NODE: 6 (N2 NOZZLE OF EXCHANGER 12-E-112B)

3 (OPE)

-56

-90

-21

24.3

-22.0

25.0

4 (SUS)

-42

-82

-20

21.3

-10.2

22.9

5 (OPE)

-36

-91

-21

23.9

-10.9

15.3

6 (OPE)

-74

-89

-19

25.4

-32.2

33.5

7 (OPE)

-53

-91

-2

33.2

-32.7

22.1

8 (OPE)

-57

-88

-39

16.0

-11.1

26.7

MAX

-74/6

-91/7

-39/8

33.2/7

-32.7/7

33.5/6

NODE: 3 (N1 NOZZLE OF EXCHANGER 12-E-112A)

3 (OPE)

-8

-110

-77

46.0

-11.4

1.2

4 (SUS)

-155

34

-13.2

0.3

5.2

5 (OPE)

14

-112

-67

39.6

0.2

12.5

6 (OPE)

-29

-108

-80

48.1

-24.9

-7.4

7 (OPE)

-9

-116

-50

29.7

-11.9

-3.7

8 (OPE)

-6

-105

-102

61.2

-10.7

6.6

MAX

-29

-155

-102

61.2

-24.9

12.5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 49 of 114

NODE: 12 (N2 NOZZLE OF EXCHANGER 12-E-112A)

3 (OPE)

-3

-87

-18.9

3.7

-1.6

4 (SUS)

-0

-132

19

24.2

2.0

3.0

5 (OPE)

20

-89

-1

-23.4

11.2

-11.7

6 (OPE)

-34

-86

-16.6

-14.3

17.5

7 (OPE)

-4

-75

82

38.1

8.1

-4.0

8 (OPE)

-3

-98

-74

-77.3

-0.9

1.0

MAX

-34/6

-132/4

82/7

-77.3/8

-14.3/6

17.5/6

NODE: 22 (N7 NOZZLE OF EXCHANGER 12-E-116D)

3 (OPE)

-59

-124

-10

31.6

-23.8

-108.4

4 (SUS)

-126

13.6

1.4

10.9

5 (OPE)

-39

-123

-10

31.6

-17.4

-75.8

6 (OPE)

-79

-125

-11

32.6

-29.7

-139.6

7 (OPE)

-53

-122

-2

33.1

-18.4

-91.6

8 (OPE)

-58

-127

-17

27.8

-26.5

-110.1

MAX

-79/6

-127/8

-17/8

33.1/7

-29.7/6

-139.6/6

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

1
2
3
3170
9150
4
6
12
22
18

FX
169
482
27
140
98
20
78
23
94
59

Load Case 2.
1
2
3
3170
9150
4
6
12
22
18

197
571
33
142
100
40
58
39
74
48

27
204
122
71
149
213
96
102
137
235

FZ
85
123
117
84
117
55
43
67
30
42

MX
24
15
75
14
19
151
39
67
75
135

MY

MZ

56
209
32
23
22
25
59
26
40
42

58
510
20
54
33
40
36
22
174
102

56
207
21
23
22
33
48
33
33
39

66
537
31
55
33
30
26
32
141
86

Design +X Wind + Seismic


31
220
124
71
148
214
97
104
137
233

Template No. 5-0000-0001-T2 Rev. 1

85
126
108
85
116
57
44
63
29
42

24
20
68
14
19
153
39
72
75
134

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


Load Case 3.
1
2
3
3170
9150
4
6
12
22
18

140
387
49
138
97
37
97
53
113
69

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 50 of 114

Design -X Wind + Seismic


18
185
120
72
149
213
95
101
138
236

84
120
120
84
118
53
42
70
30
42

24
11
77
14
19
151
40
65
76
137

56
211
46
23
21
15
69
36
46
44

51
480
26
54
32
50
44
38
205
115

24
48
58
13
17
142
48
87
76
143

56
59
33
24
25
21
70
30
34
42

57
532
22
53
32
40
33
24
157
103

25
29
90
15
21
160
31
126
71
129

57
418
31
23
19
27
48
23
42
42

58
508
25
55
33
40
37
21
175
102

Load Case 4. Design +Z Wind + Seismic


1
2
3
3170
9150
4
6
12
22
18

164
498
29
138
98
18
75
23
87
60

24
216
127
74
149
211
98
90
136
235

85
52
91
80
108
34
25
145
21
35

Load Case 5. Design -Z Wind + Seismic


1
2
3
3170
9150
4
6
12
22
18

173
488
26
141
99
20
79
22
93
59

30
207
116
69
149
216
95
114
140
235

86
267
142
88
127
76
61
137
37
48

12.3 CONCLUSION
The piping stress analysis has been carried out for piping loop from 3HT transfer pumps(12-P120) discharge to 3CT (12-C-111) after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases marginally
exceed the allowable stresses. Hence the system may be deemed to qualify the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 51 of 114

Retrofitting Scheme for Piping


13.0

Piping loop having Document number A375-000-16-43-ADC-0065

13.1 PROPOSED RETROFITTING

Table 13.1 Suggested modifications in supports

Node
No.

Previous support

New Support

2305

S9-145-1-300

S1-A-4

2090

S1-A-2

S1-A-5

2160

L1-1-

L8-1-600-T

2140
2280
2300
2110

--L6-1-1700
--S1-A-2

S1-A-5
L8-1-1700-N
S1-A-2
S1-A-2

Remarks
With 18 mm gap in +Z, 0 mm gap in Z & 0 mm gap in
X
With 3 mm gap in Z, 6 mm gap in +X, 0 mm gap in -X
& without Y guide
With 18 mm gap in +Z & 0 mm gap in -X
Guide in only +Z direction
With 25 mm gap

13.2 RESULTS AFTER RETROFITTING

Table 13.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

18764.4
28827.3
25521.0
16460.5
22115.0
23545.1

25650.0
29240.4
24749.1
24749.1
24749.1
30780.0

73.2
98.6
103.1
66.5
89.4
76.5

OK
OK
Marginal
OK
OK
OK

Status

Table 13.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

19784.1

24749.1

79.9

W+P1+F1+WIN1+SEISMIC (OCC)

33025.8

24749.1

133.4

W+P1+F1+WIN2+SEISMIC (OCC)

34906.3

24749.1

141.0

W+P1+F1+WIN3+SEISMIC (OCC)

25225.2

24749.1

101.9

10

W+P1+F1+WIN4+SEISMIC (OCC)

35703.5

30780.0

116.0

Load Case Description

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

OK
Not
Qualifed
Not
Qualifed
Marginal
Not
Qualifed

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 52 of 114

Retrofitting Scheme for Piping

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (DISCHARGE NOZZLE OF PUMP 12-P-129)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

210

-1

50

14.4

28.1

-75.6

4 (SUS)

14

-19

0.3

0.2

-3.0

5 (OPE)

244

-7

50

14.5

28.2

-85.0

6 (OPE)

157

13

48

13.9

27.6

-62.6

7 (OPE)

289

-3

46

11.5

25.2

-102.9

8 (OPE)

57

-18

54

13.1

28.1

-20.0

MAX

289/7

-19/4

54/8

14.5/5

28.2/5

-102.9/7

NODE: 2 (F1 NOZZLE OF 12-V-106)

3 (OPE)

445

182

-99

4.5

-160.9

-481.7

4 (SUS)

-1

-69

-3

-9.2

-12.1

6.7

5 (OPE)

537

200

-102

10.2

-157.9

-510.1

6 (OPE)

345

162

-96

-1.3

-162.8

-450.1

7 (OPE)

460

194

29

41.2

-6.4

-503.9

8 (OPE)

451

186

-245

-20.9

-372.7

-479.7

MAX

537/5

200/5

-245/8

41.2/7

-372.7/8

-510.1/5

NODE: 9150 (DISCHARGE NOZZLE OF PUMP 12-P-120A)

3 (OPE)

84

-103

-67

-8.3

7.8

-24.8

4 (SUS)

-22

1.6

0.8

-0.1

5 (OPE)

89

-101

-66

-8.2

8.7

-26.7

6 (OPE)

78

-105

-68

-8.4

7.3

-22.4

7 (OPE)

77

-107

-55

-6.0

11.3

-21.8

8 (OPE)

89

-100

-77

-10.4

5.3

-27.1

MAX

89/8

-107/7

-77/8

-10.4/8

11.3/7

-27.1/8

NODE: 3170 (DISCHARGE NOZZLE OF PUMP 12-P-120S)

3 (OPE)

116

-37

-52

-6.6

11.8

-41.2

4 (SUS)

-22

1.5

0.8

0.1

5 (OPE)

121

-35

-53

-6.9

12.0

-43.0

6 (OPE)

112

-37

-51

-6.6

12.5

-39.6

7 (OPE)

113

-42

-44

-4.9

13.1

-39.5

8 (OPE)

116

-35

-58

-8.3

11.4

-41.0

MAX

121/5

-42/7

-58/8

-8.3/8

13.1/7

-43.0/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 53 of 114

SEISMIC CASES (DYNAMIC)

Load Case 1.
NODE
1
2
3170
9150

FX
254
484
145
121

Load Case 2.
1
2
3170
9150

288
577
150
126

Load Case 3.
1
2
3170
9150

201
385
141
114

Design + Seismic
FY
26
204
70
145

FZ
110
123
85
110

MX
32
13
11
14

MY

MZ

91
212
24
24

90
509
54
41

91
209
24
25

100
537
56
43

31
10
11
14

90
214
24
24

78
477
52
39

29
50
9
12

88
57
25
28

118
531
52
38

30
29
13
16

91
424
23
22

35
507
54
43

Design +X Wind + Seismic


32
221
68
143

111
126
86
109

32
19
11
14

Design -X Wind + Seismic


38
183
69
148

109
120
84
111

Load Case 4. Design +Z Wind + Seismic


1
2
3170
9150

333
499
142
114

28
215
74
149

107
53
77
97

Load Case 5. Design -Z Wind + Seismic


1
2
3170
9150

102
490
145
126

43
207
68
142

115
269
91
120

13.3 CONCLUSION

The piping stress analysis has been carried out for piping loop from 3HT (12-C-110/210) liquid
dump to dump tank 12-V-106 after proposed retrofitting modifications.
The results indicate that the stresses for the individual wind and seismic load cases marginally
exceed the allowable stresses. Hence the system may be deemed to qualify the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 54 of 114

Retrofitting Scheme for Piping


14.0

Piping loop having Document number A375-000-16-43-ADC-0067

14.1 PROPOSED RETROFITTING

Table 14.1 Suggested modifications in supports

Node
No.

Previous support

New Support

450
220
500
140
330

S3-A-1-2
S3-A-1-2
S3-A-1-2
L1-1-410
S1-A-1

S3-A-2-2
S3-A-2-2
S3-A-2-2
L8-1-410-T
S1-A-2

Remarks

& without Y guide

14.2 RESULTS AFTER RETROFITTING

Table 14.2 Maximum stresses for design and wind (static) load cases

Stresses (psi)

Load
Case
No.

CAESAR Load Case

Description

4
13
18
19
20
21

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Actual

Allow.

11348.0
16258.6
23862.7
23355.2
30120.1
30120.1

25650.0
31928.3
30780.0
30780.0
30780.0
30780.0

% of
Allowable
44.2
50.9
77.5
75.9
97.9
97.9

Status
OK
OK
OK
OK
OK
OK

Table 14.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Template No. 5-0000-0001-T2 Rev. 1

Actual

Allow.

% OF
Allowable

Status

13442.7
23899.1
23844.4
25413.4
25751.0

30780
30780
30780
25789
25789

43.7
77.6
77.5
82.6
83.7

OK
OK
OK
OK
OK

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 55 of 114

Retrofitting Scheme for Piping

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (DISCHARGE NOZZLE OF PUMP 12-P-129)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

491

58

1.0

1.3

-152.2

4 (SUS)

141

18

35

22.9

19.5

-63.3

5 (OPE)

520

57

0.3

0.5

-159.5

6 (OPE)

463

58

1.5

1.9

-145.0

7 (OPE)

638

53

-5

-2.3

-2.4

-190.2

8 (OPE)

346

62

13

-0.3

1.4

-114.8

MAX

638/7

62/8

35/4

22.9/4

19.5/4

-190.2/7

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

FZ

MX

59

11

FX
513

Load Case 2.
1

542

Load Case 3.
1

485

MY

MZ

157

Design +X Wind + Seismic


58

165

150

196

Design -X Wind + Seismic


59

14

Load Case 4. Design +Z Wind + Seismic


1

660

54

10

Load Case 5. Design -Z Wind + Seismic


1

368

63

Template No. 5-0000-0001-T2 Rev. 1

18

120

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 56 of 114

14.3 CONCLUSION

The piping stress analysis has been carried out for PS condenser non-condensable line to 2HT3CT interconnecting gas line after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 57 of 114

Retrofitting Scheme for Piping

15.0

Piping loop having Document number A375-000-16-43-ADC-0068

15.1 PROPOSED RETROFITTING

Table 15.1 Suggested modifications in supports

Node
No.

Previous support

New Support

7570

S3-A-1-2

S3-A-2-2

Remarks

.
15.2 RESULTS AFTER RETROFITTING
Table 15.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

15219.6
3756.5
23188.4
21991.6
25218.7
24180.2

25650.0
36849.2
30780.0
30780.0
30780.0
30780.0

% of
Allowable
59.3
10.2
75.3
71.4
81.9
78.6

Statu
s
OK
OK
OK
OK
OK
OK

Table 15.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

19285.6
17208.7
21362.5
19842.1
25010.7

30780
30780
30780
25789
25789

62.7
55.9
69.4
64.5
81.3

OK
OK
OK
OK
OK

15.3 CONCLUSION
The piping stress analysis has been carried out for Dump tanks addl. Press balance line after
proposed retrofitting modifications.
The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 58 of 114

Retrofitting Scheme for Piping


16.0

Piping loop having Document number A375-000-16-43-ADC-0069

16.1 PROPOSED RETROFITTING

Table 16.1 Suggested modifications in supports

Node
No.

Previous support

New Support

4180
1040
4070
4220
350
4050

S1-A-1
S1-A-1
S1-A-1
S1-A-1
S1-A-1
S1-A-1

S1-A-2
S1-A-2
S1-A-2
S1-A-2
S1-A-5
S1-A-2

Remarks

With 6 mm gap

16.2 RESULTS AFTER RETROFITTING

Table 16.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

18432.8
22519.1
23871.7
26934.7
20897.5
20408.9

23172.5
24737.1
24749.1
30780.0
25788.6
25788.6

79.5
91.0
96.5
87.5
81.0
79.1

Statu
s
OK
OK
OK
OK
OK
OK

Table 16.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

25917.0

25789

100

W+P1+F1+WIN1+SEISMIC (OCC)

29170.3

24749

117.9

W+P1+F1+WIN2+SEISMIC (OCC)

27934.3

24749

112.9

W+P1+F1+WIN3+SEISMIC (OCC)

25645.9

25789

99.4

10

W+P1+F1+WIN4+SEISMIC (OCC)

26198.8

25789

101.6

Load Case Description

Status
OK
Not
Qualified
Not
Qualified
OK
Not
Qualified

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 59 of 114

Retrofitting Scheme for Piping

DESIGN AND WIND (STATIC)


NODE: 1220 (N6 NOZZLE OF EXCHANGER 12-E-117/217A)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-107

652

164

574.6

3.9

126.1

4 (SUS)

-13

-107

1.3

6.0

4.5

5 (OPE)

-77

649

175

582.0

-18.0

108.9

6 (OPE)

-132

662

156

573.6

21.1

134.9

7 (OPE)

-102

661

225

606.0

-39.1

127.8

8 (OPE)

-93

648

107

538.1

32.6

127.2

MAX

-132/6

662/6

225/7

606.0/7

-39.1/7

134.9/6

NODE: 3 (DISCHARGE NOZZLE OF PUMP 12-P-123/223A)

3 (OPE)

158

-225

289

70.9

-14.6

-73.7

4 (SUS)

-58

-5

-2.7

-0.9

0.0

5 (OPE)

171

-226

298

72.1

-14.8

-81.2

6 (OPE)

145

-216

302

73.1

-7.0

-70.0

7 (OPE)

166

-253

313

81.5

-8.3

-66.5

8 (OPE)

150

-198

264

59.9

-21.2

-81.0

MAX

171/5

-253/7

313/7

81.5/7

-21.2/8

-81.2/5

NODE: 4 (DISCHARGE NOZZLE OF PUMP 12-P-123/223S)

3 (OPE)

110

-282

35

33.8

-58.5

18.2

4 (SUS)

-57

-4

-2.2

-0.7

0.2

5 (OPE)

102

-285

47

36.3

-60.0

15.9

6 (OPE)

118

-262

32

30.3

-53.2

14.6

7 (OPE)

135

-278

96

47.6

-42.0

11.7

8 (OPE)

90

-269

-28

16.4

-75.1

18.1

MAX

135/7

-285/5

96/7

47.6/7

-75.1/8

18.2/3

NODE: 1 (F1 NOZZLE OF 12-V-105)

3 (OPE)

-17

-211

-4

14.8

28.3

217.0

4 (SUS)

-160

-325

-2

-31.1

16.6

456.7

5 (OPE)

85

-180

-8

18.4

15.6

143.2

6 (OPE)

-106

-247

-1

9.6

40.9

316.9

7 (OPE)

-7

-215

153

49.9

304.6

239.6

8 (OPE)

-14

-212

-157

-46.0

-239.5

219.4

MAX

-160/4

-325/4

-157/8

49.9/7

304.6/7

456.7/4

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 60 of 114

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

1
3
4
1220

56
236
157
142

250
288
319
738

Load Case 2.
1
3
4
1220

124
250
148
113

Load Case 3.
1
3
4
1220

146
224
164
167

FZ
59
370
137
209

MX

MY

MZ

32
91
56
625

217
43
87
51

314
99
32
179

204
43
89
65

240
107
30
162

Design +X Wind + Seismic


220
288
323
734

62
379
149
220

36
92
58
632

Design -X Wind + Seismic


287
278
299
748

56
383
133
201

27
93
52
624

229
35
82
68

414
96
29
188

67
102
69
656

493
37
71
86

336
92
26
181

63
80
38
588

428
50
104
79

316
107
32
180

Load Case 4. Design +Z Wind + Seismic


1
3
4
1220

47
245
181
137

254
315
316
746

208
394
197
270

Load Case 5. Design -Z Wind + Seismic


1
3
4
1220

54
228
136
128

252
260
307
734

211
346
130
152

16.3 CONCLUSION

The piping stress analysis has been carried out from pump ( 12-P-123) discharge to product
stripper feed after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


17.0

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 61 of 114

Piping loop having Document number A375-000-16-43-ADC-0070

17.1 PROPOSED RETROFITTING

Table 17.1 Suggested modifications in supports

Node
No.

Previous
support

1060
1155
1170
2087

17.2

New Support

Remarks

S3-A-2-2
S3-A-2-2
B40-Y-500-2 & S3-A-2-2
S3-A-1-2

Guide in Z with 7.0 mm gap


Guide gap= 0.0 mm
Guide in Z

RESULTS AFTER RETROFITTING

Table 17.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
15
16
17
18
19

CAESAR Load Case

Description

W+P1 (SUS)
DS1-DS2 (EXP)
ST2+ST11 (OCC)
ST2+ST12 (OCC)
ST2+ST13 (OCC)
ST2+ST14 (OCC)

SUSTAINED
THERMAL
+X WIND+SUS
-X WIND+ SUS
+Z WIND+ SUS
-Z WIND+ SUS

Stresses (psi)
Actual

Allow.

% of
Allowable

12,360
15,623
18,602
16,357
16,892
20,624

22,322
32,126
24,749
24,749
24,749
24,749

55.0
49.0
75.0
66.0
68.0
83.0

OK
OK
OK
OK
OK
OK

Allow.

% OF
Allowable

Status

24,749
24,749
24,749
24,749
24,749

59.0
60.0
61.0
62.0
62.0

OK
OK
OK
OK
OK

Status

Table 17.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+SEISMIC (OCC)
W+P1+WIN1+SEISMIC (OCC)
W+P1+WIN2+SEISMIC (OCC)
W+P1+WIN3+SEISMIC (OCC)
W+P1+WIN4+SEISMIC (OCC)

Actual
14,501
14,756
15,053
15,444
15,377

The actual loading obtained on the nozzles of connecting equipments by the piping analysis is
given below. The forces are in kgf and the moments are in kgf-m.
Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 62 of 114

Retrofitting Scheme for Piping


DESIGN AND WIND (STATIC)
NODE: 1020 (EXCHANGER E125/225_N8)
NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

1020

1 (OPE)

-99

31

-30

0.6

-16.8

-56.7

2 (SUS)

-7

-3.3

0.1

-1.8

3 (OPE)

-57

28

-29

0.2

-10.5

-35.1

4 (OPE)

-149

38

-51

13.0

-19.0

-82.6

5 (OPE)

-124

37

-44

13.1

-17.6

-72.3

6 (OPE)

-99

38

-78

26.6

-3.1

-54.8

MAX

-149/4

38/4

-78/6

26.6/6

-19.0/4

-82.6/4

NODE: 1280 (PRODUCT STRIPPER NOZZLE N4)


1280

1 (OPE)

32

-16

-3

2.6

7.8

-10.4

2 (SUS)

-26

-2

5.1

-0.5

3.9

3 (OPE)

82

-34

-0

6.6

20.4

-11.3

4 (OPE)

-18

-4

-1.6

-4.3

-9.8

5 (OPE)

35

-15

40

1.6

13.4

-11.2

6 (OPE)

30

-17

-43

3.2

3.7

-10.7

MAX

82/3

-34/3

-43/6

6.6/3

20.4/3

-11.3/3

NODE: 2130 (EXCHANGER E124/224_N3)


2130

1 (OPE)

48

44

-4

0.7

-0.4

3.6

2 (SUS)

-1

59

-3

0.9

0.2

4.8

3 (OPE)

81

46

-9

0.2

1.0

3.8

4 (OPE)

20

41

-1

1.1

-1.3

3.4

5 (OPE)

66

35

15

0.2

-3.2

2.9

6 (OPE)

51

50

-28

1.1

4.2

4.1

MAX

81/3

59/2

-28/6

1.1/4

4.2/6

4.8/2

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
1020
1280
2130

Design + Seismic

FX
110
36
60

FY

FZ
34
21
55

Template No. 5-0000-0001-T2 Rev. 1

MX
40
5
5

MY
6
4
1

MZ
17
9
0

64
12
4

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Load Case 7.

Design +X Wind + Seismic

1020
1280
2130

31
39
57

68
87
92

39
2
10

6
8
0

Load Case 8.

Design -X Wind + Seismic

1020
1280
2130

41
7
52

160
23
31

61
7
2

19
3
1

Load Case 9.

Design +Z Wind + Seismic

1020
1280
2130

40
20
46

135
40
77

Load Case 10.


1020
1280
2130

110
35
62

54
42
16

19
3
0

11
22
1

42
13
4

19
5
1

89
12
4

18
15
3

79
13
3

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 63 of 114

Design -Z Wind + Seismic


41
22
61

88
45
29

32
5
1

3
5
4

62
13
5

17.3 CONCLUSION

The piping stress analysis has been carried out for the piping from product stripper O/L nozzle
N4 to nozzle N8 of exchanger (12-E-125/225) & nozzle N3 of Exchanger (12-E-124/224)
after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases marginally
exceed the allowable stresses. Hence the system may be deemed to qualify the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 64 of 114

Retrofitting Scheme for Piping

18.0

Piping loop having Document number A375-000-16-43-ADC-0071

18.1

PROPOSED RETROFITTING

Table 18.1 Suggested modifications in supports

Node
No.

Previous
support

New Support

Remarks

1140

S3-A-1-2

S3-A-2-2

Guide in +X with 8.0 mm gap & Guide in -X


Guide in +X with 7.0 mm gap , Guide in -X , Guide in +Z with
7.5 mm gap & Guide in -Z
Guide in X & Guide in Z
Guide in X , Guide in +Z with 5.5 mm gap & Guide in -Z
Guide in X with 20.0 mm gap, Guide in +Z with 23.5 mm gap &
Guide in -Z
Guide in Z with 13.5.0 mm gap

1490
1565
1580

B3-L-2
S3-A-1-2

B3-L-2
S3-A-2-2, S3-A-5-2

2005

S3-A-2-2, S3-A-5-2

2010

S3-A-2-2

18.2

RESULTS AFTER RETROFITTING

Table 18.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+ SUS
-X WIND+ SUS
+Z WIND+ SUS
-Z WIND+ SUS

Stresses (psi)
Actual

Allow.

% of
Allowable

9,922
16,363
25,207
26,223
23,342
21,490

22,322
36,362
24,749
24,749
24,749
24,749

44
45
102
106
94
87

Status
OK
OK
MARGINAL
MARGINAL
OK
OK

Table 18.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7

Stresses (psi)

W+P1+F1+SEISMIC (SUS)
W+P1+F1+WIN1+SEISMIC (OCC)

8
9
10

Allow.

% of
Allowable

18,388
25,586

24,749
24,749

74.0
103.0

W+P1+F1+WIN2+SEISMIC (OCC)

28,817

24,749

116.0

W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

22,184
21,666

24,749
24,749

90.0
88.0

Load Case Description

Template No. 5-0000-0001-T2 Rev. 1

Actual

Status
OK
MARGINAL
NOT
QUALIFIED
OK
OK

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 65 of 114

Retrofitting Scheme for Piping

The actual loading obtained on the nozzles of connecting equipments by the piping analysis is
given below. The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (PURGE TOWER NOZZLE N1)
NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

3 (OPE)

-139

-363

134

-143.1

74.5

-71.2

4 (SUS)

-20

89

-50

96.1

46.0

-13.8

5 (OPE)

-208

-416

176

-143.0

158.5

46.3

6 (OPE)

-74

-312

93

-143.8

-6.2

-184.5

7 (OPE)

-111

-314

55

-230.4

108.4

-82.8

8 (OPE)

-166

-408

202

-66.9

45.0

-58.6

MAX

-208/5

-416/5

202/8

-230.4/7

158.5/5

-184.5/6

NODE: 2 (PURGE TOWER NOZZLE N2)


2

3 (OPE)

-3

88

-56

-18.8

16.2

26.6

4 (SUS)

-3

68

-16

-9.4

6.8

22.8

5 (OPE)

-67

88

-32

5.5

9.8

77.0

6 (OPE)

53

90

-82

-43.2

31.0

-12.2

7 (OPE)

89

-93

-25.2

32.2

20.9

8 (OPE)

-11

93

-44

-31.0

7.4

36.2

MAX

-67/5

93/8

-93/7

-43.2/6

32.2/7

77.0/5

NODE: 11500 (EXCHANGER 12-E-126/226_N6)


11500

3 (OPE)

-139

-535

134

149.5

83.1

676.3

4 (SUS)

-20

-132

-50

-78.5

-64.7

208.3

5 (OPE)

-320

-591

176

181.7

78.5

808.4

6 (OPE)

39

-480

93

117.8

86.8

546.5

7 (OPE)

-111

-489

-59

32.6

-70.2

620.9

8 (OPE)

-166

-576

316

260.7

224.6

727.0

MAX

-320/5

-591/5

316/8

260.7/8

224.6/8

808.4/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 66 of 114

Retrofitting Scheme for Piping


NODE: 11700 (EXCHANGER 12-E-126/226_N8)

11700

3 (OPE)

10

82

26

-90.1

19.9

-4.9

4 (SUS)

85

-3

-10.3

-5.8

-12.9

5 (OPE)

-89

79

13

-85.8

46.3

-128.2

6 (OPE)

130

117

65

-128.8

1.5

143.4

7 (OPE)

-9

66

-98

60.3

-37.0

-15.8

8 (OPE)

23

99

138

-224.8

68.8

0.3

MAX

130/6

117/6

138/8

-224.8/8

68.8/8

143.4/6

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
1
2
11500
11700

Design + Seismic

FX

FY

FZ

MX

MY

187
16
210
32

404
98
576
91

179
80
208
53

186
50
192
129

118
24
148
49

136
39
742
41

202
17
144
75

111
89
874
164

49
39
152
31

250
24
612
180

152
40
135
66

148
33
686
52

Load Case 7.

Design +X Wind + Seismic

1
2
11500
11700

457
98
632
87

255
79
391
111

221
56
250
41

185
36
224
125

Load Case 8.

Design -X Wind + Seismic

1
2
11500
11700

353
99
521
125

122
66
109
152

138
106
167
92

186
74
160
168

Load Case 9.

Design +Z Wind + Seismic

1
2
11500
11700

355
99
530
74

159
16
182
31

Load Case 10.


1
2
11500
11700

213
24
236
46

100
117
133
125

273
56
75
99

MZ

Design -Z Wind + Seismic


449
103
618
107

Template No. 5-0000-0001-T2 Rev. 1

247
68
390
166

109
62
303
264

88
15
290
98

124
48
792
36
Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 67 of 114

18.3 CONCLUSION
The piping stress analysis has been carried out for the piping from the nozzle N1 of Product
Stripper to nozzle N6 of Exchanger (12-E-126/226) & liquid back to nozzle N2 of Product
Stripper after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases marginally
exceed the allowable stresses. Hence the system may be deemed to qualify the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 68 of 114

Retrofitting Scheme for Piping

19.0

Piping loop having Document number A375-000-16-43-ADC-0072

19.1

PROPOSED RETROFITTING

Table 19.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

30
1130

S1-A-1
S3-A-1-2

S1-A-2
S3-A-2-2

Guide in +X

19.2

RESULTS AFTER RETROFITTING

Table 19.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

7965.8
12763.3
21429.4
21473.6
16780.1
14974.3

25650.0
41959.9
30780.0
30780.0
30780.0
30780.0

% of
Allowable
31.1
30.4
69.6
69.8
54.5
48.6

Status
OK
OK
OK
OK
OK
OK

Table 19.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

9474.4
14563.0
18691.5
15143.2
14435.5

30780
30780
30780
30780
30780

30.8
47.3
60.7
49.2
46.9

OK
OK
OK
OK
OK

The loading obtained on the nozzles of connecting equipments by the piping analysis is given
below. The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 69 of 114

Retrofitting Scheme for Piping


DESIGN AND WIND (STATIC)
NODE: 15 (N5 NOZZLE OF EXCHANGER 12-E-226)
CASE TYPE

FX

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

FY

-125
1
98
-205
-95
-108
-205/6

341
-107
-4
426
271
329
426/6

FZ

21
2
20
36
91
-6
91/7

MX

MY

61.5
1.3
42.7
62.3
60.4
52.7
62.3/6

-5.9
0.4
54.0
-19.5
-8.9
26.2
54.0/5

MZ

-25.5
-24.2
156.8
-29.8
19.4
-2.2
156.8/5

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

15

FX
133

Load Case 2.
15

107

Load Case 3.
15

214

384

FZ
31

MX
63

MY

MZ

10

37

58

168

Design +X Wind + Seismic


48

30

44

Design -X Wind + Seismic


469

46

64

23

41

62

13

31

30

14

Load Case 4. Design +Z Wind + Seismic


15

103

314

102

Load Case 5. Design -Z Wind + Seismic


15

117

372

17

54

19.3 CONCLUSION

The piping stress analysis has been carried out for PS condenser non-condensable line to 2HT3CT interconnecting gas line after proposed retrofitting modifications.
The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 70 of 114

Retrofitting Scheme for Piping


20.0

Piping loop having Document number A375-000-16-43-ADC-0073

20.1 PROPOSED RETROFITTING

Table 20.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

175
365
380
685
615
565
580

----C1-1-D
---------

B3-XXX-2
B39-A-L-2
C1-1-D
S1-A-2
S1-A-1
B12-L-A-2
S1-A-2

Guide in -Z with 10 mm gap, Guide +Z & Guide X

20.2

With 40 mm gap in X

Guide in Z with 8 mm gap & X with 3 mm gap

RESULTS

Table 20.2 Maximum stresses for design and wind (static) load cases according to ASME ND

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

10432.1
17380.7
22183.8
24788.0
17491.5
16956.6

25650
36716.6
25640.1
25640.1
25640.1
25640.1

40.7
47.3
86.5
96.7
68.2
66.1

OK
OK
OK
OK
OK
OK

Table 20.3 Maximum stresses for seismic (dynamic) load cases according to ASME ND

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% of
Allowable

W+P1+F1+SEISMIC (OCC)

29175.9

25640

113.8

W+P1+F1+WIN1+SEISMIC (OCC)

33185.9

25640

129.4

W+P1+F1+WIN2+SEISMIC (OCC)

33213.9

25640

129.5

W+P1+F1+WIN3+SEISMIC (OCC)

40220.3

25640

156.9

10

W+P1+F1+WIN4+SEISMIC (OCC)

33451.8

25640

130.5

Load Case Description

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Status
Marginal
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED
NOT
QUALIFIED

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 71 of 114

The loading obtained on the nozzles of connecting equipments by the piping analysis is given
below. The forces are in kgf and the moments are in kgf-m.
DESIGN AND WIND (STATIC)
NODE: 1 (Column 12-C-110/210)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-468

-3

-254.2

1.8

0.1

4 (SUS)

-586

-5

-318.7

0.5

0.0

5 (OPE)

48

-468

-3

-254.1

-26.0

37.1

6 (OPE)

-48

-478

-3

-259.6

29.5

-36.6

7 (OPE)

-0

-461

36

-279.3

2.0

-0.0

8 (OPE)

-0

-469

-43

-222.8

1.8

-0.0

MAX

48/5

-586/4

-43/8

-318.7/4

29.5/6

37.1/5

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

28

487

Load Case 2.
1

76

Load Case 3.
1

76

FZ

MX

MY

MZ

265

18

169

42

206

270

45

205

290

18

169

233

18

169

Design +X Wind + Seismic


487

265

Design -X Wind + Seismic


497

Load Case 4. Design +Z Wind + Seismic


1

28

480

40

Load Case 5. Design -Z Wind + Seismic


1

28

488

Template No. 5-0000-0001-T2 Rev. 1

47

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 72 of 114

20.3 CONCLUSION

The piping stress analysis has been carried out for DU waste to XU after proposed support
guidelines by M/s HWB .

The results indicate that the stresses for the individual wind and seismic load cases are
marginally within the allowables. Hence the system may be deemed to quality the design
adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 73 of 114

Retrofitting Scheme for Piping


21.0

Piping loop having Document number A375-000-16-43-ADC-0081

21.1

PROPOSED RETROFITTING

Table 21.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

11280

S4-A-1-16

S4-A-2-16 & S4A-5-16

Guide in X with 15 mm gap, Guide Z with 15.0 mm gap

.
21.2

RESULTS AFTER RETROFITTING

Table 21.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
17
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST13 (OCC)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

15,075
30,435
20,625
23,001
26,916
25,055

22,808
33,821
25,462
25,462
25,462
25,462

67
90
81
90
106
98

OK
OK
OK
OK
MARGINAL
OK

Table 21.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Load Case Description

Actual

Allow.

% of
Allowable

W+P1+F1+SEISMIC (OCC)

22,340

25,462

88

W+P1+F1+WIN1+SEISMIC (OCC)

28,652

25,462

113

W+P1+F1+WIN2+SEISMIC (OCC)

21,227

25,462

83

W+P1+F1+WIN3+SEISMIC (OCC)

31,295

25,462

123

10

W+P1+F1+WIN4+SEISMIC (OCC)

27,508

25,462

108

Status
OK
NOT
QUALIFIED
OK
NOT
QUALIFIED
NOT
QUALIFIED

The actual loading obtained on the nozzles of connecting equipments by the piping analysis is
given below. The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 74 of 114

Retrofitting Scheme for Piping


DESIGN AND WIND (STATIC)
NODE: 14500 (E128/228A_N2)

NODE

Load Case

FX Kg

FY Kg

FZ Kg

MX Kg.m.

MY Kg.m.

MZ Kg.m.

14500

3 (OPE)

-249

-813

154

159.1

209.3

574.4

4 (SUS)

-13

-112

-3.4

4.5

125.0

5 (OPE)

-461

-673

137

213.0

154.1

472.9

6 (OPE)

193

-582

204

-71.1

287.2

640.8

7 (OPE)

-326

-952

-59

302.9

133.7

595.4

8 (OPE)

-173

-675

406

-151.1

357.3

554.0

MAX

-461/5

-952/7

406/8

302.9/7

357.3/8

640.8/6

NODE: 15500 (E128/228C_N2)

15500

3 (OPE)

-567

-5746

-633

62.5

-100.5

2780.7

4 (SUS)

-25

-185

14

-3.0

2.4

149.9

5 (OPE)

-574

-5673

-533

60.5

-87.3

2766.1

6 (OPE)

-477

-5726

-627

55.7

-99.6

2733.3

7 (OPE)

-571

-5751

-762

18.6

-142.9

2783.7

8 (OPE)

-563

-5741

-505

106.4

-58.1

2778.1

MAX

-574/5

-5751/7

-762/7

106.4/8

-142.9/7

2783.7/7

NODE: 16500 (E128/228B_N1)

16500

3 (OPE)

227

-717

-1694

2083.3

922.9

-213.7

4 (SUS)

-45

-30

36

-43.1

-19.3

-163.6

5 (OPE)

331

-712

-1411

1739.2

767.7

-34.6

6 (OPE)

299

-739

-1693

2073.6

925.6

-153.2

7 (OPE)

221

-713

-1859

2263.6

965.5

-221.6

8 (OPE)

233

-720

-1530

1902.9

880.1

-205.6

MAX

331/5

-739/6

-1859/7

2263.6/7

965.5/7

-221.6/7

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 75 of 114

Retrofitting Scheme for Piping


NODE: 18500 (E129/229A_N2)

18500

3 (OPE)

-745

-5479

52

467.0

229.7

2823.3

4 (SUS)

-70

-182

-5.7

2.2

176.2

5 (OPE)

-726

-5364

454.0

188.8

2780.3

6 (OPE)

-775

-5594

103

479.3

272.7

2865.9

7 (OPE)

-771

-5490

-68

411.1

177.7

2841.4

8 (OPE)

-724

-5469

168

522.1

280.2

2808.5

MAX

-775/6

-5594/6

168/8

522.1/8

280.2/8

2865.9/6

NODE: 19500 (E129/229B_N1)

19500

3 (OPE)

219

-575

-1679

2068.9

910.7

-179.1

4 (SUS)

-46

-30

36

-43.0

-19.4

-165.2

5 (OPE)

338

-572

-1392

1720.4

755.3

23.9

6 (OPE)

299

-581

-1676

2059.5

909.8

-107.0

7 (OPE)

212

-576

-1843

2248.8

953.5

-190.4

8 (OPE)

226

-574

-1514

1888.8

867.7

-168.4

MAX

338/5

-581/6

-1843/7

2248.8/7

953.5/7

-190.4/7

NODE: 20500 (E129/229C_N2)

20500

3 (OPE)

-595

-5765

-628

59.0

-96.5

2800.2

4 (SUS)

-25

-185

14

-3.0

2.5

150.2

5 (OPE)

-592

-5677

-526

56.2

-84.2

2777.8

6 (OPE)

-510

-5760

-622

53.2

-93.2

2757.6

7 (OPE)

-598

-5768

-757

15.1

-139.1

2802.6

8 (OPE)

-592

-5761

-500

103.0

-53.9

2798.1

MAX

-598/7

-5768/7

-757/7

103.0/8

-139.1/7

2802.6/7

NODE: 22500 (E130/230A_N2)

22500

3 (OPE)

-141

-945

50

69.2

20.1

765.8

4 (SUS)

-65

-372

-6.8

0.0

262.4

5 (OPE)

-426

-1156

31

148.0

54.7

826.7

6 (OPE)

289

-519

88

-36.0

-2.0

678.2

7 (OPE)

-104

-911

-277

291.3

-239.7

771.8

8 (OPE)

-56

-745

508

-365.2

461.1

707.9

MAX

-426/5

-1156/5

508/8

-365.2/8

461.1/8

826.7/5

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 76 of 114

Retrofitting Scheme for Piping


NODE: 23500 (E130/230B_N1)

23500

3 (OPE)

223

-719

-1694

2082.2

923.7

-219.7

4 (SUS)

-48

-26

35

-41.8

-18.9

-167.6

5 (OPE)

331

-697

-1410

1738.3

766.7

-26.1

6 (OPE)

293

-751

-1692

2071.8

927.3

-167.1

7 (OPE)

214

-724

-1862

2262.6

967.6

-232.6

8 (OPE)

229

-722

-1526

1901.4

880.4

-211.4

MAX

331/5

-751/6

-1862/7

2262.6/7

967.6/7

-232.6/7

NODE: 24500 (E130/230C_N2)

24500

3 (OPE)

-566

-5739

-633

61.9

-101.4

2779.1

4 (SUS)

-26

-186

13

-3.1

2.4

150.9

5 (OPE)

-575

-5674

-532

60.1

-86.8

2766.9

6 (OPE)

-475

-5714

-626

54.9

-101.1

2730.1

7 (OPE)

-567

-5738

-761

17.7

-144.6

2779.8

8 (OPE)

-562

-5737

-504

106.1

-58.5

2777.2

MAX

-575/5

-5739/3

-761/7

106.1/8

-144.6/7

2779.8/7

NODE: 31500 (E127/227F_N2)

31500

3 (OPE)

682

590

232

1375.3

-460.9

-760.3

4 (SUS)

-151

1287

10

24.3

-50.5

-30.2

5 (OPE)

283

284

188

1534.4

-442.4

-1281.9

6 (OPE)

1118

856

236

1281.8

-423.4

-197.7

7 (OPE)

717

575

-72

1811.1

-192.0

-718.1

8 (OPE)

625

519

752

960.3

-1261.1

-846.6

MAX

1118/6

1287/4

752/8

1811.1/7

-1261.1/8

-1281.9/5

SEISMIC CASES (DYNAMIC)

Load Case 6.
NODE
14500
15500
16500
18500
19500
20500
22500
23500
24500
31500

Design + Seismic

FX

FY

473
641
385
786
378
670
316
377
640
1280

1306
6124
1183
5709
1047
6148
1213
1184
6115
906

Template No. 5-0000-0001-T2 Rev. 1

FZ
292
682
1745
131
1738
672
241
1745
682
742

MX
355
99
2145
539
2141
94
372
2144
98
2275

MY
304
165
986
312
975
160
220
986
165
1041

MZ
820
2851
520
2880
491
286
874
534
2853
1522
Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


Load Case 7.
14500
15500
16500
18500
19500
20500
22500
23500
24500
31500

684
648
488
767
497
667
601
486
649
881

Load Case 8.
14500
15500
16500
18500
19500
20500
22500
23500
24500
31500

416
552
456
816
458
585
464
448
549
1716

Load Case 9.
14500
15500
16500
18500
19500
20500
22500
23500
24500
31500

549
645
379
812
370
673
280
369
641
1315

Design +X Wind + Seismic


1167
6052
1179
5594
1044
6060
1423
1162
6050
600

396
637
391
765
385
666
231
384
636
1223

275
581
1462
80
1452
570
221
1460
581
698

409
97
1801
526
1793
91
450
1800
96
2434

248
151
830
271
820
148
255
829
150
1022

719
2837
341
2837
335
2845
935
340
2841
2043

382
164
988
355
974
157
202
990
164
1003

887
2804
459
2922
419
2825
786
481
2804
959

228
207
1028
260
1018
203
440
1030
208
772

841
2854
528
2898
502
2870
880
547
2854
1479

Design -X Wind + Seismic


1075
6105
1205
5824
1053
6143
786
1216
6090
1172

341
675
1744
182
1736
666
278
1743
675
745

267
92
2135
552
2132
88
338
2133
91
2182

Design +Z Wind + Seismic


1445
6130
1179
5721
1048
6152
1178
1189
6114
892

Load Case 10.


14500
15500
16500
18500
19500
20500
22500
23500
24500
31500

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 77 of 114

196
810
1910
147
1903
800
467
1913
810
582

499
55
2325
483
2321
50
594
2324
54
2711

Design -Z Wind + Seismic


1168
6120
1186
5700
1046
6145
1013
1187
6113
835

Template No. 5-0000-0001-T2 Rev. 1

544
553
1581
248
1574
543
698
1577
553
1262

347
143
1964
594
1961
138
668
1963
142
1860

452
122
943
362
932
117
661
943
122
1841

800
2849
512
2865
480
2865
816
525
2851
1608

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


21.3

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 78 of 114

CONCLUSION

The piping stress analysis has been carried out for the piping piping Between nozzle N1 & N2
of

Exchangers

12-E-127F,

12-E-128/228A/B/C/D,

12-E-129/229A/B/C/D

&

12-E-

130/230A/B/C/D (PL- Loop) after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 79 of 114

Retrofitting Scheme for Piping


22.0

Piping loop having Document number A375-000-16-43-ADC-0089

22.1

PROPOSED RETROFITTING

Table 22.1 Suggested modifications in supports

Node
No.

Previous support

New Support

12040
13150
18240

--L1-1-560
S1-A-1

19015

---

S1-A-4
L8-1-560-N
S1-A-2
B3-457-2 with
S1-A-1

22.2

Remarks
With 20 mm gap in X & without Y guide
With 6 mm gap in +Y & 18 mm gap in Z
With 44 mm gap
Without Z guide & in X

RESULTS AFTER RETROFITTING

Table 22.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Statu
s

19128.9
27361.8
23893.0
29467.0
23310.9
22537.2

25650.0
30140.1
30780.0
30780.0
30780.0
30780.0

74.6
90.8
77.6
95.7
75.7
73.2

OK
OK
OK
OK
OK
OK

Table 22.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6

Stresses (psi)
Actual

Allow.

% OF
Allowable

W+P1+F1+SEISMIC (OCC)

26503.0

30780.0

86.1

W+P1+F1+WIN1+SEISMIC (OCC)

44515.2

30780.0

144.6

W+P1+F1+WIN2+SEISMIC (OCC)

53994.9

30780.0

175.4

W+P1+F1+WIN3+SEISMIC (OCC)

31407.5

30780.0

102.0

10

W+P1+F1+WIN4+SEISMIC (OCC)

35692.2

30780.0

116.0

Load Case Description

Status
OK
Not
Qualified
Not
Qualified
Marginal
Not
Qualified

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 80 of 114

Retrofitting Scheme for Piping


DESIGN AND WIND (STATIC)
NODE: 18001 (G NOZZLE OF 12-C-101)
CASE TYPE

3 (OPE)
4 (SUS)
5 (OPE)
6 (OPE)
7 (OPE)
8 (OPE)
MAX

FX

FY

-81
41
435
-653
-75
-69
-653/6

-668
-197
-851
-392
-809
-589
-851/5

FZ

-42
26
-47
-15
399
-419
-419/8

MX

727.2
61.4
1013.2
222.0
94.1
1051.7
1051.7/8

MY

-14.8
60.3
513.6
-584.9
200.6
-123.7
-584.9/6

MZ

-248.5
0.4
749.5
-1511.9
-271.7
-160.6
-1511.9/6

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

FZ

MX

MY

18001

271

994

256

1041

239

494

737

995

809

1757

424

517

348

406

Load Case 2.
18001

625

Design +X Wind + Seismic


1176

261

1327

Load Case 3.

Design -X Wind + Seismic

18001

717

844

Load Case 4.
18001

266

229

536

Design +Z Wind + Seismic


1134

613

408

Load Case 5.

Design -Z Wind + Seismic

18001

915

260

MZ

633

1366

22.3 CONCLUSION

The piping stress analysis has been carried out for for Vent header upto XU B/L valves
after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 81 of 114

Retrofitting Scheme for Piping


23.0

Piping loop having Document number A375-000-16-43-ADC-0090

23.1

PROPOSED RETROFITTING

Table 23.1 Suggested modifications in supports

Node
No.

Previous support

New Support

125

---

S1-A-1

625
1125

-----

S1-A-1
S1-A-1

23.2

Remarks

RESULTS AFTER RETROFITTING

Table 23.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.

CAESAR Load Case

Description

4
13
18
19
20
21

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

11582.9
3680.1
13266.4
13252.6
14792.7
14507.2

25650.0
30347.8
30780.0
30780.0
30780.0
30780.0

45.2
12.1
43.1
43.1
48.1
47.1

OK
OK
OK
OK
OK
OK

Table 23.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Template No. 5-0000-0001-T2 Rev. 1

Actual

Allow.

% OF
Allowable

Status

16867.9
21252.4
22263.5
30093.8
24110.0

30780
30780
30780
30780
30780

54.8
69.0
72.3
97.8
78.3

OK
OK
OK
OK
OK

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 82 of 114

23.3 CONCLUSION

The piping stress analysis has been carried out for Drain header upto XU B/L valves after
proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are
marginally exceed the allowable stresses. Hence the system may be deemed to qualify the
design adequacy re-evaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 83 of 114

Retrofitting Scheme for Piping

24.0

Piping loop having Document number A375-000-16-43-ADC-0093

24.1

PROPOSED RETROFITTING

Table 24.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

1040
350

S1-A-1
S1-A-1

S1-A-2
S1-A-5

With 6 mm gap

24.2

RESULTS AFTER RETROFITTING

Table 24.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

18432.8
22519.1
23871.7
20824.2
19982.2
19675.1

23172.5
24737.1
25788.6
25788.6
25788.6
25788.6

79.5
91.0
82.6
80.7
77.5
76.3

Status
OK
OK
OK
OK
OK
OK

Table 24.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

25916.1
26549.7
24130.9
25644.9
26197.9

25789
25789
25789
25789
25789

100
103.0
93.6
99.4
101.6

OK
Marginal
OK
OK
Marginal

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 84 of 114

Retrofitting Scheme for Piping

DESIGN AND WIND (STATIC)


NODE: 1220 (N6 NOZZLE OF EXCHANGER 12-E-117/217A)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-107

652

164

574.6

3.9

126.1

4 (SUS)

-13

-107

1.3

6.0

4.5

5 (OPE)

-77

649

175

582.0

-18.0

108.9

6 (OPE)

-132

662

156

573.6

21.1

134.9

7 (OPE)

-102

661

225

606.0

-39.1

127.8

8 (OPE)

-93

648

107

538.1

32.6

127.2

MAX

-132/6

662/6

225/7

606.0/7

-39.1/7

134.9/6

NODE: 3 (DISCHARGE NOZZLE OF PUMP 12-P-123/223A)

3 (OPE)

158

-225

289

70.9

-14.6

-73.7

4 (SUS)

-58

-5

-2.7

-0.9

0.0

5 (OPE)

171

-226

298

72.1

-14.8

-81.2

6 (OPE)

145

-216

302

73.1

-7.0

-70.0

7 (OPE)

166

-253

313

81.5

-8.3

-66.5

8 (OPE)

150

-198

264

59.9

-21.2

-81.0

MAX

171/5

-253/7

313/7

81.5/7

-21.2/8

-81.2/5

NODE: 4 (DISCHARGE NOZZLE OF PUMP 12-P-123/223S)

3 (OPE)

110

-282

35

33.8

-58.5

18.2

4 (SUS)

-57

-4

-2.2

-0.7

0.2

5 (OPE)

102

-285

47

36.3

-60.0

15.9

6 (OPE)

118

-262

32

30.3

-53.2

14.6

7 (OPE)

135

-278

96

47.6

-42.0

11.7

8 (OPE)

90

-269

-28

16.4

-75.1

18.1

MAX

135/7

-285/5

96/7

47.6/7

-75.1/8

18.2/3

NODE: 1 (F1 NOZZLE OF 12-V-105)

3 (OPE)

-17

-211

-4

14.8

28.3

217.0

4 (SUS)

-160

-325

-2

-31.1

16.6

456.7

5 (OPE)

85

-180

-8

18.4

15.6

143.2

6 (OPE)

-106

-247

-1

9.6

40.9

316.9

7 (OPE)

-7

-215

153

49.9

304.6

239.6

8 (OPE)

-14

-212

-157

-46.0

-239.5

219.4

MAX

-160/4

-325/4

-157/8

49.9/7

304.6/7

456.7/4

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 85 of 114

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FX

FY

1
3
4
1220

56
236
157
142

250
288
319
738

Load Case 2.
1
3
4
1220

59
370
137
209

MX

MY

MZ

32
91
56
625

217
43
87
51

314
99
32
179

204
43
89
65

240
107
30
162

Design +X Wind + Seismic

124
250
148
113

220
288
323
734

Load Case 3.
1
3
4
1220

FZ

62
379
149
220

36
92
58
632

Design -X Wind + Seismic

146
224
164
167

287
278
299
748

56
383
133
201

27
93
52
624

229
35
82
68

414
96
29
188

67
102
69
656

493
37
71
86

336
92
26
181

63
80
38
588

428
50
104
79

316
107
32
180

Load Case 4. Design +Z Wind + Seismic


1
3
4
1220

47
245
181
137

254
315
316
746

208
394
197
270

Load Case 5. Design -Z Wind + Seismic


1
3
4
1220

54
228
136
128

24.3

252
260
307
734

211
346
130
152

CONCLUSION

The piping stress analysis has been carried out for V-105, V-205 & SOTP buffer tanks 27-V01/02 pressure balance line after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 86 of 114

Retrofitting Scheme for Piping


25.0

Piping loop having Document number A375-000-16-43-ADC-0095

25.1

PROPOSED RETROFITTING

Table 25.1 Suggested modifications in supports

Node
No.

Previous support

New Support

Remarks

190
210

G3-81-4
S1-A-1

S1-A-4
S1-A-2

& without Y guide


With 16 mm gap

25.2

RESULTS AFTER RETROFITTING

Table 25.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.

CAESAR Load Case

Description

4
13
18
19
20
21

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

5437.0
11982.5
24272.6
20501.8
14611.5
18002.9

25650.0
40627.5
30780.0
30780.0
30780.0
30780.0

21.2
29.5
78.9
66.6
47.5
58.5

OK
OK
OK
OK
OK
OK

Status

Table 25.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

12876.5
21584.2
22532.5
17632.0
18777.9

44187.0
30780.0
30780.0
30780.0
30780.0

29.1
70.1
73.2
57.3
61.0

OK
OK
OK
OK
OK

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 87 of 114

Retrofitting Scheme for Piping

DESIGN AND WIND (STATIC)


NODE: 1 (D NOZZLE OF 12-V-112)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-227

22

147

-82.4

186.4

-242.1

4 (SUS)

-49

-1.8

-3.0

-9.6

5 (OPE)

-160

25

170

-103.5

187.2

-193.9

6 (OPE)

-302

30

150

-84.1

186.9

-297.1

7 (OPE)

-213

24

180

-93.1

184.0

-227.1

8 (OPE)

-249

33

143

-96.5

190.3

-264.6

MAX

-302/6

-49/4

180/7

-103.5/5

190.3/8

-297.1/6

NODE: 1080 (12-V-114)

3 (OPE)

-49

-317

-21

-71.0

31.5

-376.7

4 (SUS)

-0

-74

-5.4

-17.9

25.7

5 (OPE)

235

-3

34

17.2

-12.5

-161.9

6 (OPE)

-271

-386

-76

-141.5

127.2

-236.4

7 (OPE)

-68

-318

141

102.8

-216.1

-348.9

8 (OPE)

-10

-251

-200

-274.7

356.9

-321.3

MAX

-271/6

-386/6

-200/8

-274.7/8

356.9/8

-376.7/3

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

1
1080

FX
237
98

34
337

FZ
180
53

MX
112
118

Load Case 2.

Design +X Wind + Seismic

1
1080

36
22

169
284

Load Case 3.
1
1080

311
320

Load Case 4.
1
1080

222
117

203
67

133
64

MY

MZ

187
96

249
444

188
77

201
229

188
192

304
304

185
280

234
416

Design -X Wind + Seismic


42
405

183
108

113
188

Design +Z Wind + Seismic


35
338

Template No. 5-0000-0001-T2 Rev. 1

212
173

122
149

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping


Load Case 5.
1
1080

259
59

25.3

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 88 of 114

Design -Z Wind + Seismic


45
271

176
232

126
321

191
421

271
388

CONCLUSION

The piping stress analysis has been carried out from 12-V-112 to 12-V-114 after proposed
retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 89 of 114

Retrofitting Scheme for Piping


26.0

Piping loop having Document number A375-000-16-43-ADC-0096

26.1

PROPOSED RETROFITTING

Table 26.1 Suggested modifications in supports

Node
No.

Previous support

New Support

190
1030

S9-131-5
S9-109-1

S9-131- 4
S9-109-2

26.2

Remarks
With 28 mm gap in X & without Y guide
With 16.5 mm gap

RESULTS AFTER RETROFITTING

Table 26.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Stresses (psi)
Actual

Allow.

% of
Allowable

Status

5159.2
6489.5
20099.5
21276.9
7265.9
7265.9

25650.0
41691.7
30780.0
30780.0
30780.0
30780.0

20.1
15.6
65.3
69.1
23.6
23.6

OK
OK
OK
OK
OK
OK

Table 26.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

Actual

Allow.

% OF
Allowable

Status

6522.5
21623.3
21898.3
5778.3
7878.1

30780.0
30780.0
30780.0
30780.0
30780.0

21.2
70.3
71.1
18.8
25.6

OK
OK
OK
OK
OK

The nozzle loadings of connecting equipments obtained by the piping analysis are given below.
The forces are in kgf and the moments are in kgf-m.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 90 of 114

Retrofitting Scheme for Piping

DESIGN AND WIND (STATIC)


NODE: 1 (V NOZZLE OF 12-V-115A)
CASE TYPE

FX

FY

FZ

MX

MY

MZ

3 (OPE)

-14

-220

54

97.4

58.3

182.1

4 (SUS)

-171

-7.6

0.7

9.9

5 (OPE)

75

-232

115

233.5

59.0

89.4

6 (OPE)

99

-319

123

220.8

31.3

-65.8

7 (OPE)

-9

-228

188

301.2

87.2

178.3

8 (OPE)

-11

-219

-46

-30.4

66.2

173.7

MAX

99/6

-319/6

188/7

301.2/7

87.2/7

182.1/3

NODE: 2 (V NOZZLE OF 12-V-115B)

3 (OPE)

32

-251

91

235.9

147.3

97.4

4 (SUS)

-0

-189

-4

10.3

-4.8

22.2

5 (OPE)

214

-299

49.9

159.6

-162.7

6 (OPE)

62

-313

55

174.5

163.6

-5.9

7 (OPE)

42

-250

223

436.4

178.8

74.8

8 (OPE)

19

-248

-7

108.9

153.5

124.8

MAX

214/5

-313/6

223/7

436.4/7

178.8/7

-162.7/5

SEISMIC CASES (DYNAMIC)

Load Case 1.

Design + Seismic

NODE

FY

1
2

FX
47
63

Load Case 2.
1
2

107
245

Load Case 3.
1
2

132
94

Load Case 4.
1
2

42
73

237
268

FZ
73
111

MX
128
269

MY

MZ

62
152

237
150

63
164

144
215

35
168

120
58

91
183

233
127

Design +X Wind + Seismic


248
316

133
23

264
83

Design -X Wind + Seismic


336
330

142
75

251
208

Design +Z Wind + Seismic


245
267

Template No. 5-0000-0001-T2 Rev. 1

207
243

332
469

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Load Case 5.
1
2

43
50

26.3

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 91 of 114

Design -Z Wind + Seismic


235
265

64
28

61
142

70
158

228
177

CONCLUSION

The piping stress analysis has been carried out for Vent header from individual drain tanks to
common B/L valve of drain pit after proposed retrofitting modifications.

The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 92 of 114

Retrofitting Scheme for Piping


27.0

Piping loop having Document number A375-000-16-43-ADC-0097

27.1 PROPOSED RETROFITTING

Table 27.1 Suggested modifications in supports

Node
No.

Previous support

New Support

1180

S1-A-2

S1-A-4

2200

S1-A-2

S1-A-4

1440

S1-A-2

S1-A-4

1340
2005
2050
2025
105
6060
7060
2425
30
2045

----S1-A-1
S1-A-1
--------S1-A-2
---

S1-A-1
S1-A-2
S1-A-2
S1-A-2
S1-A-2
S1-A-1
S1-A-1
S1-A-1
S1-A-1
S1-A-1

27.2

Remarks
& without
Y guide
& without
Y guide
& without
Y guide
+X guide with 10 mm gap & -X guide
With 12 mm gap

RESULTS AFTER RETROFITTING

Table 27.2 Maximum stresses for design and wind (static) load cases

Load
Case
No.
4
13
18
19
20
21

CAESAR Load Case

Description

W+P1+F1 (SUS)
DS3-DS4 (EXP)
ST4+ST14 (OCC)
ST4+ST15 (OCC)
ST4+ST16 (OCC)
ST4+ST17 (OCC)

SUSTAINED
THERMAL
+X WIND+SEISMIC
-X WIND+SEISMIC
+Z WIND+SEISMIC
-Z WIND+SEISMIC

Template No. 5-0000-0001-T2 Rev. 1

Stresses (psi)
Actual

Allow.

% of
Allowable

16939.2
27129.1
17522.6
17520.8
18102.8
18241.1

25650.0
40662.7
30780.0
30780.0
30780.0
30780.0

66.0
66.7
56.9
56.9
58.8
59.3

Copyrights EIL All rights reserved

Statu
s
OK
OK
OK
OK
OK
OK

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 93 of 114

Table 27.3 Maximum stresses for seismic (dynamic) load cases

Load
Case
No.
6
7
8
9
10

Stresses (psi)
Load Case Description
W+P1+F1+SEISMIC (OCC)
W+P1+F1+WIN1+SEISMIC (OCC)
W+P1+F1+WIN2+SEISMIC (OCC)
W+P1+F1+WIN3+SEISMIC (OCC)
W+P1+F1+WIN4+SEISMIC (OCC)

27.3

Actual

Allow.

% OF
Allowable

Status

24982.9
23182.8
22522.2
22565.3
22463.4

30780.0
30780.0
30780.0
30780.0
30780.0

81.2
75.3
73.2
73.3
73.0

OK
OK
OK
OK
OK

CONCLUSION

The piping stress analysis has been carried out for for Fire water header after proposed
retrofitting modifications.
The results indicate that the stresses for the individual wind and seismic load cases are within
the allowable stresses. Hence the system may be deemed to qualify the design adequacy reevaluation after retrofitting.

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 94 of 114

APPENDIX

EIL Piping Support Standard

Template No. 5-0000-0001-T2 Rev. 1

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 95 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 96 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 97 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 98 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 99 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 100 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 101 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 102 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 103 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 104 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 105 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 106 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 107 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 108 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 109 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 110 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 111 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 112 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 113 of 114

Copyrights EIL All rights reserved

Retrofitting Scheme for Piping

Template No. 5-0000-0001-T2 Rev. 1

Document No.
A375-000-16-43-SK-0001
Rev. No. 0
Page 114 of 114