Tip 23: How to Use Integrated Pulse Outputs for Open-Loop Control Positioning with a Seite Stepper 1 von

Motor 4

Version 4.1. Updated 08/00

How to Use Integrated Pulse Outputs for Open-Loop Control Positioning with a Stepper Motor (Tip 23) Category: Positioning Special Hardware Requirements:
l

l l l

l l l

l l l

One SIMATIC S7-200 CPU (224, 226, 226XM) Because a pulse output is used in this tip, a CPU with DC power supply, DC inputs, and DC outputs (DC/DC/DC) is required. One PC/PPI cable One programming device or PC One SIMOSTEP stepper motor, rated load torque 2 Nm, rated current IN = 1.8 A Order number: 1FL3041-0AC31-0BG0 You can find technical specifications in the online catalog CA 01, URL: http://www.ad.siemens.de/ One FM STEPDRIVE Order number: 6SN1-227-2ED10-0HA0 You can find technical specifications in the online catalog CA 01, URL: http://www.ad.siemens.de/ One motor cable, 10 m Order number: 6FX5-008 5AA00 1BA0 One sub D connector, 15-pin, for FM STEPDRIVE Order number: 6FC9 348 7HX One voltage transformer 24 VDC/5 VDC Adaptation of the voltage levels of the outputs of the S7-200 to the pulse interface of the FM STEPDRIVE Resistors or Calex Model 8502 You can find data sheets under: http://www.calex.com or http://www.recom-electronic.com One cable for control signals to power section One simulator for S7-200

Project Example Print this Tip Positioning tasks differentiate between closed-loop control and open -loop control operations. Stepper motors do not require continuous position control and therefore are used in open-loop control mode. This program example achieves relative positioning with a stepper motor drive by using the integrated pulse outputs of the SIMATIC S7-200 CPU 224. Although a reference point is not necessary for this type of positioning, the example describes a simple procedure for specifying a reference bit because, from a practical standpoint, it makes sense to assign a fixed reference point to an axis. Next, this example program uses an input byte in binary format to provide the CPU with the positioning angle. From this information, the program then calculates the number of required positioning steps and causes the CPU to read out a corresponding number of control pulses.

Description FM STEPDRIVE The FM STEPDRIVE power section is used to drive three-phase stepper motors. Motors in the lower range of performance can be driven with 5 W to 600 W.

Interfaces of the FM STEPDRIVE Power Section


Pulse Interface The module can be driven with clock signals of a higher level positioning unit by means of the pulse

file://D:\T&T\English\tips\tip23.htm

05.08.2002

Tip 23: How to Use Integrated Pulse Outputs for Open-Loop Control Positioning with ...a Seite Stepper 2 von Motor 4

interface. For each clock pulse, the motor executes one step. Note: The pulse interface has 5V optocoupler inputs and therefore cannot be connected to the controller directly. Note: The pulse interface has 5V optocoupler inputs and therefore cannot be connected to the controller directly. Input Signals: PULSE DIR ENABLE PWM Output signals: READY1_N Ready status After the ENABLE input is activated, the power section reports that it of the output READY1_N. Clock pulse Direction of rotation Enable Current control

Each positive pulse edge causes one step of the motor if it is ready to at the GATE N input.

For a de-energized signal input DIR, the motor turns clockwise; for an input, the motor turns counterclockwise. If the ENABLE input is energized, the power section is enabled. The level of the motor phase current that is set can be changed with modulated signal.

Signal Interface The signals of the higher level controller that are fed in at the PULSES input can be enabled for driving the motor by means of the GATE_N input of the signal interface. The signal interface has 24V inputs. Inputs: GATE_N Enables the clock pulse signal

When there are 24 V at the GATE_N input, the signals tha the PULSES input are used for driving the stepper motor. pending signals are disabled.

Outputs: ZERO READY2 MSTILL Zero signal ring counter Ready status Motor stopped

In the zero position of the internal ring counter, there are 2 output.

After the ENABLE input is activated, the power section rep ready by means of the READY2 output.

If the clock pulse signal is disabled by means of the GATE motor is brought to a standstill, this standstill is acknowled MSTILL sign.

Parameters of the FM STEPDRIVE You assign parameters for the motor phase current, the number of steps, and the current decrement by means of the switch for current and parameter. Selector switch for motor phase current: 0 -> I N = 1.7 A (for SIMOSTEP stepper motor 1FL3041 0AC31 0BG0)

file://D:\T&T\English\tips\tip23.htm

05.08.2002

Tip 23: How to Use Integrated Pulse Outputs for Open-Loop Control Positioning with ...a Seite Stepper 3 von Motor 4

Voltage Conversion for the Driver of the Stepper Motor The following figures show how you can easily create a circuit in order to connect the programmable logic controller to the drive of the stepper motor that requires a 5V current-sinking signal. As an option, you can also use a Calex converter (such as a Model 8502) to generate a 5V current-sinking signal.

As an option, you can also use a Calex converter (such as a Model 8502) to generate a 5V current-sinking signal.

Note: For the pulse train output (PTO) function, the switching times of the outputs for the switching procedures On/Off and Off/On are different. This difference is evident as a distortion of the relative duty cycle. The PTO outputs require a minimum load of 10% of the rated load in order to generate clean transitions. Without the load, the stepper motor could lose steps when switching from one pulse rate to another.

Program Description

file://D:\T&T\English\tips\tip23.htm

05.08.2002

Tip 23: How to Use Integrated Pulse Outputs for Open-Loop Control Positioning with ...a Seite Stepper 4 von Motor 4

Input and Output Definitions Inputs: I0.0 to I0.7 I1.0 I1.1 I1.4 I1.5 Outputs: Q0.0 Q0.2 Q0.3 Q1.0 Pulse Output Direction of Rotation Indicator Drive Enabled Indicator Reference Angle Indicator Reference Angle (in binary format) Motor START Motor STOP Set/Delete Reference Angle Direction of Rotation

Copyright 2002 Siemens Energy & Automation


SIMATIC S7 -200 customers have free use of the application tips. These tips are only a general approach to using the S7 -200 with various applications. Your specific application may be different. It is your responsibility to use the SIMATIC S7-200 properly in your applications.