FIBRAS PTICAS : MONOMODO Y MULTIMODO OPTIMIZADAS FRENTE A CURVATURAS

Renato Flvio Cruz


Gerencia Tcnica de Cables - GTC Directoria de Marketing 55-41-3341-4052 55-41-9994-3860 rfcruz@furukawa.com.br

Slide: 1

Fibras pticas Optimizadas frente Curvaturas

Necesidad y Factores
FTTH Red ptica Pasiva NETWORKING Data Center

Fibras pticas Optimizadas frente Curvaturas

FIBRAS MONOMODO (SMF)


FTTH Red ptica Pasiva

Fibras pticas Optimizadas frente Curvaturas FIBRA MONOMODO BAJA PRDIDA FRENTE CURVATURA (BLI)
Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network

Is fully compliant with the G.652 single mode fibres and G.657 can also be used in other parts of the network CLASS A Are suitable to be used in the O, E, S, C and L-band (i.e. throughout the 1260 to 1625 nm range) is not necessarily compliant with G.652 but is capable of low values of macrobending losses at very low bend G.657 radii and is pre-dominantly intended for in-building use CLASS B Are suitable for transmission at 1310, 1550, and 1625 nm for restricted distances that are associated with inbuilding transport of signals

Slide: 4

Conceptos de Redes pticas Pasivas

Acceso Individual

Acceso Colectivo

Conceptos de Redes pticas Pasivas

Infraestructura de la Rede ptica Pasiva


TOPOLOGIA La particularidad de cada red FTTP exige estudio y proyecto de ingeniara caso a caso

Cables pticos de Acceso, Cables de COMPONENTES Acometida, Cajas de empalmes, bastidores, y DA REDE conectores La atenuacin de los componentes pasivos determinan significativamente el alcance mximo da red. Exige selecto criterios de:

PRESUPUESTO DE POTENCIA

- Fibra ptica
- Divisores de potencia (splitters) y Filtros WDM - Conectores

Slide: 6

Conceptos de Redes pticas Pasivas

Presupuesto Potencia en 1310nm Classe B+ para 20km

Cables Acceso

24 - 27%

Splitters 70 - 80%

Conectores y Fusiones: 2 - 6%

Cable Drop < 0,5%

CATV Video
WDM

1550 nm

1 x 32

ONT

OLT

1490 nm
Slide: 7

1310 nm

Presupuesto de Potencia ptica


G-PON Gigabit Passive Optical Network ITU-T G.984.2
Presupuesto de Potencia (Upstream)
Disponible entre OLT y ONU Sistema de Componentes 4 Conectores SC 6 Empalmes por Fusin Splitters 1 x 32 Total parcial Atenuacin de la Fibra ptica Alcance Mximo

PXPX-20U (1310nm): 28 dB en 20 km Comn 2,40 0,50 20,0 22,9 0,40 Seleccionado 0,60 0,33 18,0 18,93 0,34

12,8 km

26,7 km

Prdidas por curvaturas


Reach Reduction from Macrobending Loss at 1550 nm
Reach Reduction (KM) 14 12 10 8 6 4 2 0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 Reach Reduction - 0.25 dB/KM modern low loss fiber

* Assumes loss limited link with no margin

Macro-Bending Loss (dB)

Solamente 2 dB de prdidas por curvatura podr reducir en 8 km !!! Meta para prdida por curvatura: 0 dB

Prdidas por curvaturas

Prdidas por curvatura de fibra SM estndar podrn interrumpir los servicios o reducir el alcance total de la rede acceso PON

Fibras pticas Optimizadas frente Curvaturas


FIBRA MONOMODO ESTNDAR ITU-T G652 C / D O
0.9 0.6 0.3

wavelength E

(nm) S

Fibra SM G.652 A,B

Fibra SM G.652 con vuelta de 20mm dimetro

Fibra SM G.652 C, D

O1 O2 O3 O4 O5 E1 E2 E3 E4 E5 S1 S2 S3 C1 C2 L1 L2 L3
1270 1290 1310 1330 1350 1370 1390 1410 1430 1450 1470 1490 1510 1530 1550 1570 1590 1610

Performance por Macrocurvatura

(100 vueltas x Dimetro 60mm)


Slide: 11

Mximo 0,1 dB en 1550nm

Fibras pticas Optimizadas frente Curvaturas

G.657 CLASS A

G.657 CLASS B

Slide: 12

Fibras pticas Optimizadas frente Curvaturas Radio de Curvatura Reducido para garantizar una prdida mxima de 0.2dB en curvatura con dimetro de 20mm
73% superior frente lmites del estndar G657A

ITU/T G657 A

20mm Mandrel
Slide: 13

15mm Mandrel

Fibras pticas Optimizadas frente Curvaturas

Radio mnimo Curvatura y Mxima Prdida en 1550nm (1 vuelta)

0,2dB en 10 mm (G657A) o 7,5mm (G657B) 0,1dB en 5 mm (excede G657 A e B)

?????

Slide: 14

Fibras pticas Optimizadas frente Curvaturas


GRAPA

R = 5.5

Optimizada para aplicaciones en proyectos FTTH y MDU Radios de curvatura de hasta 5mm Productos: Cordones e Cables acometida horizontal
http://br.youtube.com/ofsmarcom
15

Fibras pticas Optimizadas frente Curvaturas


Radio mnimo de curvatura deber ser >= 7.5mm para Garantizar 40 anos con 1 ppm confiabilidad

1p p m Probabilidad fa ilu re p rofalla b a b por lity metro fo r a de 1 ppm me tre ptica of b en t fib re fibra curvada
Fiber Lifetime (years)
35 30 25 20 15 10 5 0 0 10 5 20 10 30 15

Chance de ruptura

Sistema Confiable

B e nd D ia m e te r (m m) Radio Curvatura (mm)

Fibras pticas Optimizadas frente Curvaturas


Revised Recommendation G.657 (for consent)
A = Access Network Applications B = Indoor Building Applications
Radius (mm) 15 10 7.5 5 10 1 1 1 Number of turns (nm) 1550 1625 1550 1625 1550 1625 1550 1625 Maximum Macrobending (dB) A1 A2 & B2 B3 0.25 0.03 1 0.1 0.1 0.03 0.75 0.2 0.1 1.5 0.08 0.5 0.25 1 0.15 0.45

A1: G.652.D fiber with slightly reduced Bend Losses (BL) formerly G.657.A A2: G.652.D fiber with Strong BL reduction (focused on 7.5mm radius) - formerly G.652.D
& G.657B

B2: Strong BL reduction (focused on 7.5mm radius);


mandatory - formerly G.657.B

compliance with G.652.D is not

B3: Strong BL reduction (focused on 5mm bend radius); compliance with G.652.D is not
mandatory - New Table

Fibras pticas Optimizadas frente Curvaturas


Fibras monomodo BLI (Bending Low Insensitive): Tecnologas distintas entre los proveedores
Matched Clad Fiber

Slide: 18

Infraestructura da Rede ptica Pasiva

Slide: 19

Infraestructura da Rede ptica Pasiva

Slide: 20

Acceso Vertical MDU (Multi-dwelling unit)

Indoor Multi-fiber Cable


Drop Box

Single Fiber Drops to each living unit

Outdoor Cable Indoor Cabinet housing 1 x 32 splitters Can serve 32 units for each outdoor fiber

Slide: 21

Acceso Vertical MDU (Multi-dwelling unit)


Termination Box Termination Box
Bridal Rings

Bridal Rings

Tight buffer drop cables

Tight Buffer Drop Cables

Cable Ties to the Steel Messenger

Cable Ties to the Steel Messenger

Slide: 22

Acceso Vertical MDU (Multi-dwelling unit)

Slide: 23

Fibras pticas Optimizadas frente Curvaturas

FIBRAS MULTIMODO (MMF)


NETWORKING Data Center

Soluciones para Cableado Estructurado

SFP ????

Performance

Cat7/7a component

Cat6a component

Cat6 component
FutureCom

"Small Form Factor Pluggable" (SFP) It interfaces a network device mother board (for a switch, router, media converter or similar device) to a fiber optic or copper networking cable.

Fully compliant with IEEE 802.3an, ANSI/TIA/EIA-568-B.2-10-CAT6A, ISO/IEC 11801:2002/Amd1:2008, Class EA


250MHz 500MHz 1000MHz 10GHz

100MHz

Soluciones para Cableado Estructurado Optical fiber within the ETHERNET (IEEE 802.3)
1995 1998 2002

10Mbps 1987
FOIRL 10BASE-FL

100Mbps

1000Mbps

10Gbps 40Gbps 100Gbps

1000BASE-SX 1000BASE-LX

10GBASE-SX

1994: 100BASE-FX 2000: 100BASE-SX

LED 850 & 1310nm 50 & 62.5m MMF

VCSEL 850nm 50m MMF (OM3 / OM4)

Soluciones para Cableado Estructurado


Kilowatts

Power Consumption with Cooling

22 20 18 16 14
Fiber

12 10 8 6 4 2 0 1 100

Copper (4 watts) Copper (10 watts)

200

300

400

500
# units

600

700

800

900

1000

10Gb/s Ethernet Power Consumption Copper 10GBaseT : Multimode Fiber 10GBaseSR:

4-10 Watts 1 Watt

Fibras Multimodo para Cableado Estructurado - clases

10, 40, & 100 Gb/s Transceiver Designation 10GBase-SR (10 Gb/s) 10GBase-LX4 (10 Gb/s) 10GBase-LRM (10 Gb/s) 40GBase-SR4 (draft) (40 Gb/s) 100GBase-SR10 (draft) (100Gb/s)
1Mode 2With

Wavelength

62.5 um (OM1)

Std 50 um (OM2)

LO 50 um (OM3)

LO 50 um (OM4)

SM (OS1)

850 nm Serial VCSEL 1300 nm CWDM Laser 1300 nm serial Laser/EDC 850 nm Parallel VCSEL Array 850 nm Parallel VCSEL Array

33 300 220
1

82 300 220
1

300 300 220

550
300 220

NA 10,000 NA

NA

NA

100

150 150

NA

NA

NA

100

NA

Conditioning Patch-cords required 1.0dB connector loss

Data Center Arquitectura tpica

Level
Core

Media Network Speed


Fiber 100 Gb/s

10

Aggregation/ Distribution
Fiber 100 Gb/s

10

Access
(Top of Rack, Mid-Row, End of Row) Server
Fiber - 10 Gb/s Copper - 1 10 Gb/s (Distance Related)

Data center link lengths


Will migrate to 16 Gb/s serial OM3 and OM4

0-100 m 0-300 m

0-200 m
Will move to 40100 Gb/s Parallel OM3 and OM4

0-200 m

Data from Alan Flatmann presented to IEE 802.3 High speed study group January 2008

Fibras pticas Optimizadas frente Curvaturas

MULTIMODO MM50 OM3 & OM4 BEND-OPTIMIZED

Principales Caractersticas: Optimizada para aplicaciones en proyectos de data center Radios de curvatura de hasta 7,5mm Mayor confiabilidad para redes FTTD DMD controlado para garantizar 10 Gbps hasta 550 metros

Fibras pticas Optimizadas frente Curvaturas

Fibras pticas Optimizadas frente Curvaturas


288-port High288High-Density Housings in 4RU Space with BendBend-Insensitive Fibers
Double the density of traditional Plug & Play

Fibras pticas Optimizadas frente Curvaturas

Minimum bend radius is 5x cable OD instead of the traditional 10x cable OD

Fibras pticas Optimizadas frente Curvaturas

Reduccin del tamao de los mdulos (Cassetes)

Muchas Gracias!