A Wide Variety of High-precision Temperature Sensors
Ideal for the thermal input devices of Temperature Controllers. Select from a wide variety of Temperature Sensors according to the temperature to be measured, location, and environment, and also according to the type and shape of the terminal. General-purpose, low-cost, and exclusive models are available.
Ordering Information
List of Models
Classification Description Model and appearance Temperature range (See note.) Element type Conductor type Class Protective tubing material Terminal type Page
Generalpurpose Models
Sheathed E52-P@A platinum resistance E52-P@C thermometer Standard E52-P@B platinum resistance E52-P@C thermometer Sheathed thermocouple E52-CA@A E52-IC@A E52-CA@B E52-IC@B E52-CA@C E52-IC@C Standard thermocouple E52-CA@B E52-IC@B E52-CA@C E52-IC@C E52-PR@C
SUS316
0C to 450C
0C to 1,050C
K (CA) J (IC)
Nongrounded type
2 (0.75)
SUS316 Inconel
Exposed F-9 lead wires Exposed terminals Enclosed terminals F-13 F-13 F-14 F-15 F-16
0C to 1,000C
SUS316 SUS310S
0C to 1,400C
R (PR)
2 (0.25)
Enclosed terminals
Temperature Sensor
E52
F-1
Classification
Description
Element type
Conductor type
Class
Terminal type
Page
Low-cost Models
Low-cost E52-P10AE E52-P6D platinum resistance E52-P6F thermometer Low-cost thermocouple E52-CA@AS E52-IC@AS E52-CA1D E52-IC1D E52-CA6F E52-IC6F E52-CA10AE E52-IC10AE
50C to 250C
Pt100
SUS304
0C to 400C
K (CA) J (IC)
2 (0.75)
F-19
F-20
Nongrounded type
F-22
Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing.
F-2
Classification
Description
Element type
Conductor type
Class
Terminal type
Page
Exclusive Models
E52-CA2GV E52-IC2GV
K (CA) J (IC)
SUS304
E52-CA1GT E52-IC1GT
F-23
E52-P2GS Used for measuring surface temperatures E52-P10GR Used for room temperature measurement Double-el- E52-P20GW ement model E52-P10GP Waterproof model E52-P5A-40
50C to 250C
Pt100
F-23
50C to 60C
F-24
50C to 250C
0C to 70C
Two 3-conductor systems 3-conductor system PFA molding Pt100 K (CA) 3-conduc- B tor system Nongrounded type 2 (0.75) PFA tubing
F-24
F-25
F-26
F-25
E52-CA1D-40
0C to 300C
K (CA)
---
F-29
SUS316
Enclosed terminals
F-27
Thermistors
SUS304
Note: 1. General-purpose models and low-cost models are provided on the previous pages. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing.
Temperature Sensor
E52
F-3
Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors. Accessory Compression Fitting Temperature range 600C max. Mounting with Compression Fitting Mounting example Page F-32
Terminal box Compression Fitting PT screw Welding Protective tubing
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C max. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones.
Loose Flange
400C max.
Lead Wires
Accessory For resistance thermometers Standard Heat resistive For thermocouples (compensating conductor) Standard Heat resistive Specification Vinyl-covered with twelve 0.18-dia. conductors (0.3 mm thick) and 4.8 mm in outer dia. Temperature range Page ---
20C to 70C
Glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) ex- 0C to 180C Sleeve: 0C to 100C ternally shielded, 5.2 mm in outer dia. Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and 3.2 x 5.0 mm in outer dia. Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) externally shielded, 2.9 x 4.6 mm in outer dia.
20C to 70C
0C to 150C Sleeve: 0C to 100C
F-34
General-purpose Models
Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend on page F-8 for the Pt100.
Specifications
Element type Class Sheath material Sheath outer diameter Conductor type Temperature range Pt100 JIS class B SUS316 3.2 dia., 4.8 dia., 6.4 dia. 3-conductor system
F-4
Exposed-lead Models
E52-P@A
Dimensions
Y-type crimp terminal for M4 Maker tube Lead wire d M L
Unit (mm)
SUS304 sleeve SUS316 sheath D
Lead Wire d 8 8 8 l 60 60 60 Standard (20C to 70C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0C and 70C. Heat Resistive (0C to 180C): Fully glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) externally shielded, 5.2 mm in outer dia. The sleeve resists a temperature range between 0C and 100C. Lead Wire Length (M): 1, 2, 4, or 8 m
Model Information
Custom-made models are available on request. Refer to page F-8 for details. Terminal type Protective tubing diameter D (mm) 3.2 dia. Protective tubing length L (cm) 15 Lead wire type Lead wire length M (m) 1 E52-P15A D=3.2 1M E52-P15A D=3.2 NETU 1M E52-P20A D=3.2 1M E52-P20A D=3.2 NETU 1M E52-P35A D=3.2 1M E52-P35A D=3.2 NETU 1M E52-P20A D=4.8 1M E52-P20A D=4.8 NETU 1M E52-P35A D=4.8 1M E52-P35A D=4.8 NETU 1M E52-P50A D=4.8 1M E52-P50A D=4.8 NETU 1M E52-P20A D=6.4 1M E52-P20A D=6.4 NETU 1M E52-P35A D=6.4 1M E52-P35A D=6.4 NETU 1M E52-P50A D=6.4 1M E52-P50A D=6.4 NETU 1M 2 Model Standard Heat resistive 20 Standard Heat resistive 35 Standard Heat resistive 4.8 dia. 20 Standard Heat resistive 35 Standard Heat resistive 50 Standard Heat resistive 6.4 dia. 20 Standard Heat resistive 35 Standard Heat resistive 50 Standard Heat resistive E52-P15A D=3.2 2M E52-P15A D=3.2 NETU 2M E52-P20A D=3.2 2M E52-P20A D=3.2 NETU 2M E52-P35A D=3.2 2M E52-P35A D=3.2 NETU 2M E52-P20A D=4.8 2M E52-P20A D=4.8 NETU 2M E52-P35A D=4.8 2M E52-P35A D=4.8 NETU 2M E52-P50A D=4.8 2M E52-P50A D=4.8 NETU 2M E52-P20A D=6.4 2M E52-P20A D=6.4 NETU 2M E52-P35A D=6.4 2M E52-P35A D=6.4 NETU 2M E52-P50A D=6.4 2M E52-P50A D=6.4 NETU 2M E52-P15A D=3.2 4M E52-P15A D=3.2 NETU 4M E52-P20A D=3.2 4M E52-P20A D=3.2 NETU 4M E52-P35A D=3.2 4M E52-P35A D=3.2 NETU 4M E52-P20A D=4.8 4M E52-P20A D=4.8 NETU 4M E52-P35A D=4.8 4M E52-P35A D=4.8 NETU 4M E52-P50A D=4.8 4M E52-P50A D=4.8 NETU 4M E52-P20A D=6.4 4M E52-P20A D=6.4 NETU 4M E52-P35A D=6.4 4M E52-P35A D=6.4 NETU 4M E52-P50A D=6.4 4M E52-P50A D=6.4 NETU 4M E52-P15A D=3.2 8M E52-P15A D=3.2 NETU 8M E52-P20A D=3.2 8M E52-P20A D=3.2 NETU 8M E52-P35A D=3.2 8M E52-P35A D=3.2 NETU 8M E52-P20A D=4.8 8M E52-P20A D=4.8 NETU 8M E52-P35A D=4.8 8M E52-P35A D=4.8 NETU 8M E52-P50A D=4.8 8M E52-P50A D=4.8 NETU 8M E52-P20A D=6.4 8M E52-P20A D=6.4 NETU 8M E52-P35A D=6.4 8M E52-P35A D=6.4 NETU 8M E52-P50A D=6.4 8M E52-P50A D=6.4 NETU 8M 4 8
Exposed-lead Models
Temperature Sensor
E52
F-5
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
34 dia. 57 Aluminum die-cast terminal box SUS304 65 4 16 19 Cap G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) 35 L Use wiring terminals that fit M3 screws. SUS316 sheath D
Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (A, B, b).
Model Information
Custom-made models are available on request. Refer to page F-8 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. E52-P20C D=3.2 E52-P35C D=3.2 E52-P50C D=3.2 --4.8 dia. Model Enclosed-terminal Models 20 35 50 75 E52-P20C D=4.8 E52-P35C D=4.8 E52-P50C D=4.8 E52-P75C D=4.8 E52-P20C D=6.4 E52-P35C D=6.4 E52-P50C D=6.4 E52-P75C D=6.4 6.4 dia.
Specifications
Element type Class Protective tubing material Conductor type Temperature range Pt100 JIS class B (See note 2.) SUS316 3-conductor system 0C to 450C (in dry air)
Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. 2. Be sure that the thermometer is free of vibration or shock if high temperatures are measured.
F-6
Exposed-terminal Models
E52-P@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Aluminum die-cast terminal box SUS316 protective tubing
Model Information
Custom-made models are available on request. Refer to page F-8 for details Terminal type Protective Protective tubing diameter D (mm) tubing length 8 dia. L (cm) Model 20 35 50 E52-P20B D=8 E52-P35B D=8 E52-P50B D=8
10 A 50 B B 18 Three, M3 20 20 dia. 40
D 14 dia.
Exposedterminal Models
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
34 dia. 57 SUS316 protective tubing 10 65 14 dia. Aluminum die-cast terminal box (See note 1.) L 40 Use wiring terminals that fit M3 screws. 8 dia. 90 10 40 dia. Cap
1
Cap G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in)
35
Note: 1. The length L is in centimeters, but 40 is 40 millimeters. Therefore, for the E52-P20C, L = 20 (cm), the protective tubing length L 40 = 200 40 = 160 mm. 2. The length L is in centimeters, but 50 is 50 millimeters. Therefore, for the E52-P75C: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm. 3. Terminal box: The permissible temperature is 0C to 80C.
Model Information
Custom-made models are available on request. Refer to page F-8 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 8 dia. Model Enclosed-terminal Models 20 35 50 75 100 E52-P20C D=8 E52-P35C D=8 E52-P50C D=8 ------E52-P35C D=10 E52-P50C D=10 E52-P75C D=10 E52-P100C D=10 10 dia.
Temperature Sensor
E52
F-7
Specify for E52-@@A model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@A only: Range: 1 to 100 m
3. Terminal A: Exposed lead wires B: Exposed terminals C: Enclosed terminals Note: Lead wires without crimp terminals (Y) are also available.
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42A D=4.8 NETU 10M
F-8
Sheathed Thermocouples
Specifications
Element type Class Thermal contact Sheath material K (CA), J(IC) JIS class 2 (0.75) Non-grounded type CA: SUS316 IC: SUS316 1 dia. 1.6 dia. 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. Permissible Temperature in Dry Air D 650C 650C 750C 800C 800C 900C Element wire K (CA) SUS316 J (IC) SUS316 450C 450C 650C 750C 750C 750C
Exposed-lead Models
E52-CA@A
Dimensions
Y-type crimp terminal for M4 Red (+) Lead wire (See note 1.) d White () M L SUS304 sleeve (See note 2.)
Unit (mm)
SUS316 sheath D
Permissible Temperature in Dry Air d 7 7 7 7 10 10 l 40 40 40 40 45 45 1 dia. 1.6 dia. 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. D Element wire K (CA) SUS316 650C 650C 750C 800C 800C 900C
D 1 dia. 1.6 dia. 3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Note: 1. Lead Wire (Compensating Conductor) Standard (20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 3.2 5.0. Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield and external dimensions of 2.9 4.6 Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between 20C and 70C for standard models and 0C and 100C for heat-resistive models.
Temperature Sensor
E52
F-9
Terminal type
Protective Protective tubing diameter tubing length L D (mm) (cm) 3.2 dia. 15
Lead wire type 1 Standard Heat resistive E52-CA15A D=3.2 1M E52-CA15A D=3.2 NETU 1M E52-CA20A D=3.2 1M E52-CA20A D=3.2 NETU 1M E52-CA35A D=3.2 1M E52-CA35A D=3.2 NETU 1M E52-CA50A D=3.2 1M E52-CA50A D=3.2 NETU 1M E52-CA20A D=4.8 1M E52-CA20A D=4.8 NETU 1M E52-CA35A D=4.8 1M E52-CA35A D=4.8 NETU 1M E52-CA50A D=4.8 1M E52-CA50A D=4.8 NETU 1M E52-CA20A D=6.4 1M E52-CA20A D=6.4 NETU 1M E52-CA35A D=6.4 1M E52-CA35A D=6.4 NETU 1M E52-CA50A D=6.4 1M E52-CA50A D=6.4 NETU 1M E52-CA20A D=8 1M E52-CA20A D=8 NETU 1M E52-CA35A D=8 1M E52-CA35A D=8 NETU 1M E52-CA50A D=8 1M E52-CA50A D=8 NETU 1M
Lead wire length M (m) 2 Model E52-CA15A D=3.2 2M E52-CA15A D=3.2 NETU 2M E52-CA20A D=3.2 2M E52-CA20A D=3.2 NETU 2M E52-CA35A D=3.2 2M E52-CA35A D=3.2 NETU 2M E52-CA50A D=3.2 2M E52-CA50A D=3.2 NETU 2M E52-CA20A D=4.8 2M E52-CA20A D=4.8 NETU 2M E52-CA35A D=4.8 2M E52-CA35A D=4.8 NETU 2M E52-CA50A D=4.8 2M E52-CA50A D=4.8 NETU 2M E52-CA20A D=6.4 2M E52-CA20A D=6.4 NETU 2M E52-CA35A D=6.4 2M E52-CA35A D=6.4 NETU 2M E52-CA50A D=6.4 2M E52-CA50A D=6.4 NETU 2M E52-CA20A D=8 2M E52-CA20A D=8 NETU 2M E52-CA35A D=8 2M E52-CA35A D=8 NETU 2M E52-CA50A D=8 2M E52-CA50A D=8 NETU 2M 4 E52-CA15A D=3.2 4M E52-CA15A D=3.2 NETU 4M E52-CA20A D=3.2 4M E52-CA20A D=3.2 NETU 4M E52-CA35A D=3.2 4M E52-CA35A D=3.2 NETU 4M E52-CA50A D=3.2 4M E52-CA50A D=3.2 NETU 4M E52-CA20A D=4.8 4M E52-CA20A D=4.8 NETU 4M E52-CA35A D=4.8 4M E52-CA35A D=4.8 NETU 4M E52-CA50A D=4.8 4M E52-CA50A D=4.8 NETU 4M E52-CA20A D=6.4 4M E52-CA20A D=6.4 NETU 4M E52-CA35A D=6.4 4M E52-CA35A D=6.4 NETU 4M E52-CA50A D=6.4 4M E52-CA50A D=6.4 NETU 4M E52-CA20A D=8 4M E52-CA20A D=8 NETU 4M E52-CA35A D=8 4M E52-CA35A D=8 NETU 4M E52-CA50A D=8 4M E52-CA50A D=8 NETU 4M 8 E52-CA15A D=3.2 8M E52-CA15A D=3.2 NETU 8M E52-CA20A D=3.2 8M E52-CA20A D=3.2 NETU 8M E52-CA35A D=3.2 8M E52-CA35A D=3.2 NETU 8M E52-CA50A D=3.2 8M E52-CA50A D=3.2 NETU 8M E52-CA20A D=4.8 8M E52-CA20A D=4.8 NETU 8M E52-CA35A D=4.8 8M E52-CA35A D=4.8 NETU 8M E52-CA50A D=4.8 8M E52-CA50A D=4.8 NETU 8M E52-CA20A D=6.4 8M E52-CA20A D=6.4 NETU 8M E52-CA35A D=6.4 8M E52-CA35A D=6.4 NETU 8M E52-CA50A D=6.4 8M E52-CA50A D=6.4 NETU 8M E52-CA20A D=8 8M E52-CA20A D=8 NETU 8M E52-CA35A D=8 8M E52-CA35A D=8 NETU 8M E52-CA50A D=8 8M E52-CA50A D=8 NETU 8M
Exposed-lead Models
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
F-10
Exposed-lead Models
E52-IC@A
Dimensions
Y-type crimp terminal for M4 Red (+) Lead wire (See note 1.) d White () M L SUS304 sleeve (See note 2.)
Unit (mm)
SUS316 sheath D
Permissible Temperature in Dry Air d 7 7 7 7 10 10 l 40 40 40 40 45 45 1 dia. 1.6 dia. 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. D Element wire J (IC) SUS316 450C 450C 650C 750C 750C 750C
D 1 dia. 1.6 dia. 3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Note: 1. Lead Wire (Compensating Conductor) Standard (20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 3.2 5.0. Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield and external dimensions of 2.9 4.6 Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between 20C and 70C for standard models and 0C and 100C for heat-resistive models.
Exposed-lead Models
Temperature Sensor
E52
F-11
Terminal type
Lead wire length M (m) 1 E52-IC15A D=3.2 1M E52-IC15A D=3.2 NETU 1M E52-IC20A D=3.2 1M E52-IC20A D=3.2 NETU 1M E52-IC35A D=3.2 1M E52-IC35A D=3.2 NETU 1M E52-IC50A D=3.2 1M E52-IC50A D=3.2 NETU 1M E52-IC20A D=4.8 1M E52-IC20A D=4.8 NETU 1M E52-IC35A D=4.8 1M E52-IC35A D=4.8 NETU 1M E52-IC50A D=4.8 1M E52-IC50A D=4.8 NETU 1M E52-IC20A D=6.4 1M E52-IC20A D=6.4 NETU 1M E52-IC35A D=6.4 1M E52-IC35A D=6.4 NETU 1M E52-IC50A D=6.4 1M E52-IC50A D=6.4 NETU 1M E52-IC20A D=8 1M E52-IC20A D=8 NETU 1M E52-IC35A D=8 1M E52-IC35A D=8 NETU 1M E52-IC50A D=8 1M E52-IC50A D=8 NETU 1M 2 Model E52-IC15A D=3.2 2M E52-IC15A D=3.2 NETU 2M E52-IC20A D=3.2 2M E52-IC20A D=3.2 NETU 2M E52-IC35A D=3.2 2M E52-IC35A D=3.2 NETU 2M E52-IC50A D=3.2 2M E52-IC50A D=3.2 NETU 2M E52-IC20A D=4.8 2M E52-IC20A D=4.8 NETU 2M E52-IC35A D=4.8 2M E52-IC35A D=4.8 NETU 2M E52-IC50A D=4.8 2M E52-IC50A D=4.8 NETU 2M E52-IC20A D=6.4 2M E52-IC20A D=6.4 NETU 2M E52-IC35A D=6.4 2M E52-IC35A D=6.4 NETU 2M E52-IC50A D=6.4 2M E52-IC50A D=6.4 NETU 2M E52-IC20A D=8 2M E52-IC20A D=8 NETU 2M E52-IC35A D=8 2M E52-IC35A D=8 NETU 2M E52-IC50A D=8 2M E52-IC50A D=8 NETU 2M 4 E52-IC15A D=3.2 4M E52-IC15A D=3.2 NETU 4M E52-IC20A D=3.2 4M E52-IC20A D=3.2 NETU 4M E52-IC35A D=3.2 4M E52-IC35A D=3.2 NETU 4M E52-IC50A D=3.2 4M E52-IC50A D=3.2 NETU 4M E52-IC20A D=4.8 4M E52-IC20A D=4.8 NETU 4M E52-IC35A D=4.8 4M E52-IC35A D=4.8 NETU 4M E52-IC50A D=4.8 4M E52-IC50A D=4.8 NETU 4M E52-IC20A D=6.4 4M E52-IC20A D=6.4 NETU 4M E52-IC35A D=6.4 4M E52-IC35A D=6.4 NETU 4M E52-IC50A D=6.4 4M E52-IC50A D=6.4 NETU 4M E52-IC20A D=8 4M E52-IC20A D=8 NETU 4M E52-IC35A D=8 4M E52-IC35A D=8 NETU 4M E52-IC50A D=8 4M E52-IC50A D=8 NETU 4M 8 E52-IC15A D=3.2 8M E52-IC15A D=3.2 NETU 8M E52-IC20A D=3.2 8M E52-IC20A D=3.2 NETU 8M E52-IC35A D=3.2 8M E52-IC35A D=3.2 NETU 8M E52-IC50A D=3.2 8M E52-IC50A D=3.2 NETU 8M E52-IC20A D=4.8 8M E52-IC20A D=4.8 NETU 8M E52-IC35A D=4.8 8M E52-IC35A D=4.8 NETU 8M E52-IC50A D=4.8 8M E52-IC50A D=4.8 NETU 8M E52-IC20A D=6.4 8M E52-IC20A D=6.4 NETU 8M E52-IC35A D=6.4 8M E52-IC35A D=6.4 NETU 8M E52-IC50A D=6.4 8M E52-IC50A D=6.4 NETU 8M E52-IC20A D=8 8M E52-IC20A D=8 NETU 8M E52-IC35A D=8 8M E52-IC35A D=8 NETU 8M E52-IC50A D=8 8M E52-IC50A D=8 NETU 8M
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
F-12
Exposed-terminal Models
E52-CA@B E52-IC@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Aluminum die-cast terminal box 22 dia SUS316 sheath + 45 4 16 Two, M3 40 16 L D
Permissible Temperature in Dry Air D 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. 750C 800C 800C 900C Element wire K (CA) SUS316 J (IC) SUS316 650C 750C 750C 750C
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details. Element type Terminal type Protective tubing length L (cm) 20 35 50 75 J (IC) Exposed-terminal Models 20 35 50 75 Protective tubing diameter D (mm) 3.2 dia. E52-CA20B D=3.2 E52-CA35B D=3.2 E52-CA50B D=3.2 --E52-IC20B D=3.2 E52-IC35B D=3.2 E52-IC50B D=3.2 --4.8 dia. Model K (CA) Exposed-terminal Models E52-CA20B D=4.8 E52-CA35B D=4.8 E52-CA50B D=4.8 E52-CA75B D=4.8 E52-IC20B D=4.8 E52-IC35B D=4.8 E52-IC50B D=4.8 E52-IC75B D=4.8 E52-CA20B D=6.4 E52-CA35B D=6.4 E52-CA50B D=6.4 E52-CA75B D=6.4 E52-IC20B D=6.4 E52-IC35B D=6.4 E52-IC50B D=6.4 E52-IC75B D=6.4 --E52-CA35B D=8 E52-CA50B D=8 E52-CA75B D=8 --E52-IC35B D=8 E52-IC50B D=8 E52-IC75B D=8 6.4 dia. 8 dia.
Enclosed-terminal Models
E52-CA@C E52-IC@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
34 dia. 57 14 dia. SUS316 sheath D 4 16 19 Aluminum die-cast terminal box L-40 Use wiring terminals that fit M3 screws.
Permissible Temperature in Dry Air D 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. 750C 800C 800C 900C Element wire K (CA) SUS316 J (IC) SUS316 650C 750C 750C 750C
65
Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (+ or ).
Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in)
Temperature Sensor
E52
F-13
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details. Element type Terminal type Protective tubing length L (cm) 20 35 50 75 J (IC) Enclosed-terminal Models 20 35 50 75 Protective tubing diameter D (mm) 3.2 dia. E52-CA20C D=3.2 E52-CA35C D=3.2 E52-CA50C D=3.2 --E52-IC20C D=3.2 E52-IC35C D=3.2 E52-IC50C D=3.2 --4.8 dia. Model K (CA) Enclosed-terminal Models E52-CA20C D=4.8 E52-CA35C D=4.8 E52-CA50C D=4.8 E52-CA75C D=4.8 E52-IC20C D=4.8 E52-IC35C D=4.8 E52-IC50C D=4.8 E52-IC75C D=4.8 E52-CA20C D=6.4 E52-CA35C D=6.4 E52-CA50C D=6.4 E52-CA75C D=6.4 E52-IC20C D=6.4 E52-IC35C D=6.4 E52-IC50C D=6.4 E52-IC75C D=6.4 --E52-CA35C D=8 E52-CA50C D=8 E52-CA75C D=8 --E52-IC35C D=8 E52-IC50C D=8 E52-IC75C D=8 6.4 dia. 8 dia.
Standard Thermocouples
Specifications
Element wire Class Protective tubing material K (CA), J(IC), R K (CA), J (IC) JIS class 2 (0.75) R, JIS class 2 (0.25) K (CA) SUS316 J (IC) SUS316 R (See JIS ceramic cat. 1 (PT1) note.) JIS special ceramic (PT0) Thermal contact Non-grounded type D 17 dia. Element wire R 0C to 1,400C 10 dia. 12 dia. 15 dia. 22 dia.
Exposed-terminal Models
E52-CA@B E52-IC@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Aluminum die-cast terminal box 50 10 + 70 22 dia. L D SUS316 protective tubing
26
Two, M3
Terminal box: The permissible temperature is 0C to 100C. Permissible Temperature in Dry Air D 10 dia. 12 dia. 15 dia. 22 dia. 750C 850C 850C 900C Element wire K (CA) SUS316 J (IC) SUS316 450C 500C 550C 600C
F-14
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details Element type Terminal type Protective tubing length L (cm) 35 50 75 100 J (IC) Exposed-terminal Models 35 50 75 100 Protective tubing diameter D (mm) 10 dia. E52-CA35B D=10 E52-CA50B D=10 E52-CA75B D=10 E52-CA100B D=10 E52-IC35B D=10 E52-IC50B D=10 E52-IC75B D=10 E52-IC100B D=10 12 dia. Model K (CA) Exposed-terminal Models E52-CA35B D=12 E52-CA50B D=12 E52-CA75B D=12 E52-CA100B D=12 E52-IC35B D=12 E52-IC50B D=12 E52-IC75B D=12 E52-IC100B D=12 E52-CA35B D=15 E52-CA50B D=15 E52-CA75B D=15 E52-CA100B D=15 E52-IC35B D=15 E52-IC50B D=15 E52-IC75B D=15 E52-IC100B D=15 --E52-CA50B D=22 E52-CA75B D=22 E52-CA100B D=22 --E52-IC50B D=22 E52-IC75B D=22 E52-IC100B D=22 15 dia. 22 dia.
Enclosed-terminal Models
E52-CA@C E52-IC@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
98 Aluminum die-cast terminal box 22 dia. SUS316 protective tubing
Element wire K (CA) SUS316 750C 850C 850C 900C J (IC) SUS316 450C 500C 550C 600C
22 dia.
90 10 40 dia. Cap
Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (+ or ).
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details Element type Terminal type Protective tubing length L (cm) 35 50 75 100 J (IC) Enclosed-terminal Models 35 50 75 100 Protective tubing diameter D (mm) 10 dia. E52-CA35C D=10 E52-CA50C D=10 E52-CA75C D=10 E52-CA100C D=10 E52-IC35C D=10 E52-IC50C D=10 E52-IC75C D=10 E52-IC100C D=10 12 dia. Model K (CA) Enclosed-terminal Models E52-CA35C D=12 E52-CA50C D=12 E52-CA75C D=12 E52-CA100C D=12 E52-IC35C D=12 E52-IC50C D=12 E52-IC75C D=12 E52-IC100C D=12 E52-CA35C D=15 E52-CA50C D=15 E52-CA75C D=15 E52-CA100C D=15 E52-IC35C D=15 E52-IC50C D=15 E52-IC75C D=15 E52-IC100C D=15 --E52-CA50C D=22 E52-CA75C D=22 E52-CA100C D=22 --E52-IC50C D=22 E52-IC75C D=22 E52-IC100C D=22 15 dia. 22 dia.
Temperature Sensor
E52
F-15
Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (+ or ).
57
100
Model Information
Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 17 dia. Model R (See note 1.) R (See note 2.) Enclosed-ter- 50 minal Models 75 100 Enclosed-ter- 50 minal Models 75 100 E52-PR50C D=17 PT1 E52-PR75C D=17 PT1 E52-PR100C D=17 PT1 E52-PR50C D=17 PT0 E52-PR75C D=17 PT0 E52-PR100C D=17 PT0
Standard
Protective tubing material Mullite, high alumina, etc. Recrystallized alumina, fused alumina, etc.
Permissible temperature in dry air 1,500C (See note.) 1,700C (See note.)
Note 1: JIS ceramic Cat.1 (PT1) Note 2. JIS special ceramic (PT0)
Note: The permissible temperature given for the protective tubing is higher than 1,400C, but the permissible temperature of the thermocouple element wire is only 1,400C. Therefore, the protective tubing of the E52-PR@C can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire.
F-16
Thermocouples
E52-@@@ D=@@@M@
1 2 3 4 5 6 7
4. Diameter Specify the protective tubing material according to the table. Code 1 1.6 3.2 4.8 6.4 8 10 12 15 22 17 E52-@@B and E52-@@C (except E52-PR@C) Diameter (D) 3.2 4.8 6.4 8.0 10 12 15 22 E52-PR@C Diameter (D) 17 Length (L) 50, 75, 100 --Inconel SUS310S PT1 PT0 Length (L) 11 to 2,000 14 to 2,300 16 to 1,200 18 to 1,000 21 to 126 24 to 126 29 to 156 39 to 206 NETU Diameter Protective tubing (D) construction 1 mm 1.6 mm 3.2 mm 4.8 mm 6.4 mm 8 mm 10 mm 12 mm 15 mm 22 mm 17 mm Sheathed Sheathed Sheathed Sheathed Sheathed Sheathed Standard Standard Standard Standard Standard Protective tubing material SUS316 SUS316 SUS316 SUS316 SUS316, Inconel SUS316, Inconel SUS316, SUS310S SUS316, SUS310S SUS316, SUS310S SUS316, SUS310S PT1, PT0 1. Element type CA: K IC: J PR: R 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) E52-@@A (Exposed-lead Model) Diameter (D) 1 1.6 3.2 4.8 6.4 8 Length (L) 2 to 200 3 to 500 5 to 2,000 8 to 2,300 10 to 1,200 12 to 1,000
5. Heat resistance Specify this item for the exposed-lead models only. Code --Temperature range Lead type Vinyl-covered Glass-wool-covered with external shield
6. Lead length (M) Specify the length in meters in the following range for the E52@@A only. Range: 1 to 100 m 7. Protective tubing material Code Protective tubing material SUS316 Inconel SUS310S JIS ceramic Cat.1 JIS special ceramic K, J K, D = 6.4 to 8 K, D = 10 to 22 R R Element type
3. Terminal A: Exposed lead wires (element type: K, J) B: Exposed terminals (element type: K, J) C: Enclosed terminals (element type: K, J, R) Note: Lead wires without crimped terminals (Y) are also available.
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA42A D=4.8 NETU 10M Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2 E52-IC36C D=3.2
Temperature Sensor
E52
F-17
Low-cost Models
Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Specifications
Element type Conductor type Class Protective tubing material Sensor length Temperature range Lead wire Pt100 3-conductor system Class B SUS304 30 mm
4 dia.
E52-P6D
Dimensions
Tapered pipe thread Argon arc welding SUS304 R1/8 Silicone tubing SUS304 (t0.25) Caulking
Fluoroplastic-covered wire with 1.0 outer dia. each (PFA) 7/0.18 Red (A)
14
65
10 6
Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) 1 2 4 Model E52-P6D 1M E52-P6D 2M E52-P6D 4M
E52-P6F
Dimensions
Flange Three, 3.5 dia. 120 SUS304 Fluoroplastic-covered wire with 1.0 outer dia. each Silicone tubing (PFA) 7/0.18 Caulking Red (A) White (B) Silver soldering Y-type crimp terminal for M4 30 M 15 White (B)
20 dia. 30 dia.
1 65
Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) 1 2 4 Model E52-P6F 1M E52-P6F 2M E52-P6F 4M
Exposed-lead Models
Specifications
Element type Conductor type Class Protective tubing material Sensor length Temperature range Lead wire Pt100 3-conductor system Class B SUS304 20 mm
30 100 3.2 0.1 dia. SUS304 (t0.25) Silicone shrinkable tubing
E52-P10AE
Dimensions
Fluoroplastic-covered wire with 1.0 outer dia. each Caulking (PFA) 7/0.18 Red (A) White (B) Y-type crimp terminal for M4 M White (B)
Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting.
F-18
Low-cost Thermocouples
Exposed-lead Models with Spring
Specifications
Element type Element dia. Class Protective tubing material Thermal contact Temperature range Lead wire K (CA), J (IC) 0.65 mm (single wire) Class 2 (0.75) SUS304
4.8 dia.
E52-CA@AS, E52-IC@AS
Dimensions
L SUS304 (t0.4) 32
12 dia.
M 150 80 Red (+) White () Y-type crimp terminal for M4 Color code (K: Blue, J: Yellow)
Sleeve Brass-nickel Closely wound plating spring coil Fully glass-wool-covered compensating cable with four 0.65-dia. conductors and external dimensions of approx. 5.1 3.0
Note: The sleeve resists temperatures ranging between 0C and 100C. Note: The protective tubing is of pipe construction, which must not be bent. Protective tubing length (mm) 65 1 2 4 100 1 2 4 150 1 2 4 200 1 2 4 Lead wire length (m) Element type: K (CA) Model E52-CA6AS 1M E52-CA6AS 2M E52-CA6AS 4M E52-CA10AS 1M E52-CA10AS 2M E52-CA10AS 4M E52-CA15AS 1M E52-CA15AS 2M E52-CA15AS 4M E52-CA20AS 1M E52-CA20AS 2M E52-CA20AS 4M E52-IC6AS 1M E52-IC6AS 2M E52-IC6AS 4M E52-IC10AS 1M E52-IC10AS 2M E52-IC10AS 4M E52-IC15AS 1M E52-IC15AS 2M E52-IC15AS 4M E52-IC20AS 1M E52-IC20AS 2M E52-IC20AS 4M Element type: J (IC)
Temperature Sensor
E52
F-19
E52-CA1D, E52-IC1D
Dimensions
0.65-dia. 2.8 thermocouple element B 3.8 dia. White () Color code 5 dia. (K: Blue, SUS304 Crimp terminal for M4 J: Yellow) screw (W1/4) Enamel-bonded Covered with black insulation tubing copper wire Fully glass-wool-covered cable with external shield and external dimensions of approx. 3.1 2.0 1 10 A C M Color tubing Brass (K: Blue, J: Yellow) 80 Red (+)
Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, Internal Construction (E52-CA1D) or W1/4) when ordering. 0.65-dia. 3. The thermocouple is not of airtight black wire Closely wound Movable ring Brass enamel-bonded coil. construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact.
End Workpiece Cut after silver soldering M6 Screw Brass pipe Shielded glasswool lead wire
Note: E52-CA1D with the same shape and multiple element wires are also available. Refer to page F-29 for details. Protective tubing length (mm) M6 screw 1 2 4 M8 screw 1 2 4 W1/4 screw 1 2 4 Lead wire length (m) Element type: K (CA) Model E52-CA1D M6 1M E52-CA1D M6 2M E52-CA1D M6 4M E52-CA1D M8 1M E52-CA1D M8 2M E52-CA1D M8 4M E52-CA1D W1/4 1M E52-CA1D W1/4 2M E52-CA1D W1/4 4M E52-IC1D M6 1M E52-IC1D M6 2M E52-IC1D M6 4M E52-IC1D M8 1M E52-IC1D M8 2M E52-IC1D M8 4M E52-IC1D W1/4 1M E52-IC1D W1/4 2M E52-IC1D W1/4 4M Element type: J (IC)
F-20
E52-CA6F, E52-IC6F
Dimensions
Fully glass-wool-covered tubing with external dimensions of 3.6 2.2 Solder processed Red (+) Color code (K: Blue, J: Yellow) M White () 80 10
4 dia. 1 15 30
Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) 1 2 4 Element type: K (CA) E52-CA6F 1M E52-CA6F 2M E52-CA6F 4M Element type: J (IC) E52-IC6F 1M E52-IC6F 2M E52-IC6F 4M
Model
E52-CA6D, E52-IC6D
Dimensions
Fully glass-wool-covered Tapered pipe thread tubing with external dimensions of 3.6 2.2 Argon arc welding SUS304 Solder processed R1/8 SUS304 Silicone tubing Red stripe (+) Blue stripe () 4 dia. 14 65 10 6 15 30 80 10 M Color code (K: Blue, J: Yellow)
Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) 1 2 4 Element type: K (CA) E52-CA6D 1M E52-CA6D 2M E52-CA6D 4M Element type: J (IC) E52-IC6D 1M E52-IC6D 2M E52-IC6D 4M
Model
Temperature Sensor
E52
F-21
Exposed-lead Models
Specifications
Element type Element diameter Class Protective tubing material Thermal contact Temperature range Lead wire K (CA), J (IC) 0.32 mm (single wire) Class 2 (0.75) SUS304 Non-grounded type 0C to 350C: K (CA) 0C to 200C: J (IC) 0C to 180C
80 100 M Color code (K: Blue, J: Yellow) 3.2 0.1 dia. SUS304 Caulking
E52-CA10AE, E52-IC10AE
Dimensions
2.8-max. outer-dia. fully glass-woolcovered tubing Red (+) White ()
Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Lead wire length M: 1, 2, or 4 m 3. The protective tubing is of pipe construction, which must not be bent. 4. The thermocouple cannot be mounted using a PT@ Compression Fitting. Lead wire length (m) 1 2 4 Element type: K (CA) E52-CA10AE 1M E52-CA10AE 2M E52-CA10AE 4M Element type: J (IC) E52-IC10AE 1M E52-IC10AE 2M E52-IC10AE 4M
Model
Exclusive Models
Thermocouples
Thermocouples for Molding Machines
Specifications
Element type Element diameter Class Protective tubing material Thermal contact Temperature range Lead wire K (CA), J (IC) 1.0 mm (single wire) Class 2 (0.75) SUS304 Grounded type 0C to 350C 0C to 180C
25 15 105 22 Closely wound spring coil Bayonet 4.8 dia. SUS304 6.8 dia. M3 screw 11-dia. spring metal fitting 4.1-outer-dia. glass-wool-covered cable with external shield Red (+) White () Color code Y-type crimp (K: Blue, J: Yellow) terminal for M4 15 10 25 Brass-nickel plating Adapter (provided) R1/8
E52-CA2GV, E52-IC2GV
Dimensions
12 dia.
Model
F-22
E52-CA1GT, E52-IC1GT
Dimensions
4.2-max. outer-dia. glass-woolcovered cable with externally braided shield (+) red () white Y-type crimp terminal for M4
Note: The E52-CA1GT is also available with double elements. Refer to page F-24 for details. Lead wire length (m) 1 2
Model
E52-P2GS
Dimensions
Silicone-covered 3-conductor cable Brass-nickel-plated bracket with twelve 0.18-dia. conductors (0.3-mm thick) Four, 3.2 dia. 6-dia. SUS304 and approx. 4.8 dia. sleeve Press Red (A) 20 14 5 50 20 28 6 1.5 Approx. 32 Silicone tubing M 80 Y-type crimp terminal for M4 Lead wire length (M): 1 or 2 m White (B) Black (B)
Temperature Sensor
E52
F-23
E52-P10GR
Dimensions
Aluminum alloy 6.7-outer-dia. vinylcovered 3-conductor cable 65 dia. (twenty 0.18-dia. conductors, 0.5 mm thick)
3-conductor system
92 78 20 dia.
20C to 70C
Y-type crimp terminal for M4 100 80 97 2,000
55
7 dia.
PF1/2
Model E52-P10GR 2M
E52-P20GW
Dimensions
Fully vinyl-covered lead cable with twenty 0.18-dia. conductors (0.5 mm thick)
Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) 1 2 Model E52-P20GW 1M E52-P20GW 2M
F-24
E52-P10GP
Dimensions
7.6-outer-dia. vinyl-covered 3conductor cable (thirty 0.18-dia. conductors, 0.75 mm thick) Y-type crimp terminal for M4 Red (A) White (B) Black (B) 100 62 5 M Lead wire length (M): 2 or 4 m
Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5A-40 if waterproof lead wires are required for use underwater. Refer to page F-26 for details. Lead wire length (m) 2 4 Model E52-P10GP 2M E52-P10GP 4M
E52-CA20A-1
Dimensions
Protective Covering tubing diameter thickness (mm) D = 4.6 D = 6.0 D = 8.0 0.7 0.6 0.8 2 2 2
Temperature Sensor
E52
F-25
Platinum Measurement
Exposed-lead Models
Specifications
Element type Class Protective tubing material Conductor type Temperature range Lead wire Pt100 Class B SUS316 with PFAcovered (FEP) tube 3-conductor system
Red (A) White (B) Black (B) 2,000 60 FEP-covered tubing 200
E52-P20A-1
Dimensions
Y-type crimp terminal for M4 Araldite resin Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Sheath D
Lead wires
80C to 180C
Vinyl-covered: 20C to 70C
Protective Coating tubing diameter thickness (mm) D = 4.6 D = 6.0 D = 8.0 0.7 0.6 0.8 2 2 2
E52-P5A-40
Dimensions
FEP mold 7 dia. PFA-covered wire 7/0.18 Red (A) White (B) White (B)
50C to 180C
PFA-covered (PFA): 50C to 180C
F-26
E52-CA@@C-6
Dimensions
L L1 115 Hexagonal slot, 22 between flats
15 dia. 84 dia.
Explosion Construction Pressure-resistant explosion-proof structure -proof specificat Explosiond2G4 ions protected class and ignitability Lead wire wiring method Conduit thread Installation method Metal conduit connected with screws to terminal box PF1/2 Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan)
18 77 PF1/2
Model E52-CA20C-6 D=6.4 L2=150 E52-CA35C-6 D=6.4 L2=300 E52-CA50C-6 D=6.4 L2=450 E52-CA75C-6 D=6.4 L2=700
E52-P@@C-6
Dimensions
L L1 115 Hexagonal slot, 22 between flats
SUS316
15 dia. 84 dia.
Explosion Construction Pressure-resistant explosion-proof structure -proof specificat Explosiond2G4 ions protected class and ignitability Lead wire wiring method Conduit thread Installation method Metal conduit connected with screws to terminal box PF1/2 Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan)
18 77 PF1/2
Model E52-P20C-6 D=6.4 L2=150 E52-P35C-6 D=6.4 L2=300 E52-P50C-6 D=6.4 L2=450 E52-P75C-6 D=6.4 L2=700
Temperature Sensor
E52
F-27
Double-element Models
Thermocouple
Exposed-lead Models
Specifications
Element type Class Protective tubing material Thermal contact Temperature range Lead wire K (CA) Class 2 (0.75) SUS316 (with sheath) Non-grounded type 0C to permissible temperature limit Vinyl-covered: 20C to 70C
Red (+) White () Red (+) White () 80 2,000 45 200
E52-CA20A-7
Dimensions
Compensating conductor d Sleeve Protective tubing D
Permissible Temperature in Dry Air D 3.2 dia. 4.8 dia. 6.4 dia. 8.0 dia. Element wire K (CA) SUS316 750C 850C 850C 900C Model E52-CA20A-7 D=3.2 2M E52-CA20A-7 D=4.8 2M E52-CA20A-7 D=6.4 2M E52-CA20A-7 D=8.0 2M Protective tubing diameter D = 3.2 D = 4.8 D = 6.4 D = 8.0 Permissible Temperature (C) 750 800 800 900 2 2 2 2 Lead wire length (m)
E52-P20A-7
Dimensions
Y-type crimp terminal for M4 Lead wires Sleeve (SUS304) Caulking
3-conductor system
Black (B1) White (B1) Brown (A2) Yellow (B2) Green (B2) 80
200C to 450C
Vinyl-covered: 20C to 70C
F-28
Enclosed-terminal Models
Specifications
Element type Class Protective tubing material Conductor type Temperature range Pt100 Class B SUS316 (with sheath) 3-conductor system
80 dia. 98 40 dia. Terminal box Protective tubing D
E52-P20C-7
Dimensions
200C to 450C
57
150
E52-CA1D-40
Dimensions
M Silicone covering 80
Screw pitch 1 2 4
E52-CA1GT-14
Dimensions
M4, round, crimp terminal 6.5 Silicone-covered compensating cable with thirty 0.1-dia. conductors and external dimensions of 3.5 4.9
Lead wire length (M): 1 or 2 m Model E52-CA1GT-14 1M E52-CA1GT-14 2M Lead wire length (m) 1 2
Temperature Sensor
E52
F-29
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Temperature range Color code Blue Black Red Yellow Green Nominal resistance 6 kW (0C) 6 kW (0C) 30 kW (0C) 0.55 kW (200C) 4 kW (200C) Thermistor constant 3390K 3390K 3450K 4300K 5133K Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 1.55 Lead wire A pair of 0.12 dia. 7 PFA-insulated stranded wires with 0.86 outer dia. each
50C to 50C
0C to 100C 50C to 150C 100C to 200C 150C to 300C
Specifications
Item Coupling method Class Protective tubing material Time constant Dissipation factor Lead wire heat resistive temperature JIS class 1 SUS304 8 to 15 s in still water 2.4 to 2.8 mW/C in still air 180C E52-THE@@ Element interchangeable thermistor
Error
Detectable temperature Error
50C to 100C
100C to 350C
Permissible Temperature
Detectable temperature Operating temperature 100C 150C 200C 250C 350C
50C to 50C
0C to 100C 50C to 150C 100C to 200C 150C to 300C
Note: Models with non-standard lead wire length and protective tubing length are available on request. This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.
F-30
Exposed-lead Models
E52-THE5A
Dimensions
SUS304 t0.25 4 dia. 15 50 1,030 50 10 Lead wires (See note.) Color code
Note: The lead wires have no polarity Temperature range Model E52-THE5A 50-50C 1M E52-THE5A 0-100C 1M E52-THE5A 50-150C 1M E52-THE5A 100-200C 1M E52-THE5A 150-300C 1M
50C to 50C
0C to 100C 50C to 150C 100C to 200C 150C to 300C
Temperature range
Model E52-THE6D 50-50C 1M E52-THE6D 0-100C 1M E52-THE6D 50-150C 1M E52-THE6D 100-200C 1M E52-THE6D 150-300C 1M
50C to 50C
0C to 100C
Color code
Temperature range
Model E52-THE6F 50-50C 1M E52-THE6F 0-100C 1M E52-THE6F 50-150C 1M E52-THE6F 100-200C 1M E52-THE6F 150-300C 1M
50C to 50C
0C to 100C
Color code
15
50 10
Note: 1. The Thermistor lead cable can be extended, but do not use a standard lead wire for extension. If waterproof performance is required, be sure that the lead cable joint is of waterproof construction as well. 2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the temperature range.
Temperature Sensor
E52
F-31
Accessories
Compression Fittings
Model Information
Model Screw of part Applicable a protective tubing diameter R 1/8 1.0 dia. 1.6 dia. 3.2 dia. 4.8 dia. R 1/4 3.2 dia. 4.8 dia. 6.4 dia. R 3/8 R 1/2 M 12 8 dia. 10 dia. 4.8 dia. 5 8 5 19 23.5 15 15 19.5 12 21 26 17 17 21 14 5 15 12 17 14 Dimension b 5 c 13 d 10 14 Flat diameter Part c PT 1/8 D=1.0 PT 1/8 D=1.6 PT 1/8 D=3.2 PT 1/8 D=4.8 PT 1/4 D=3.2 PT 1/4 D=4.8 PT 1/4 D=6.4 PT 3/8 D=8 PT 1/2 D=10 M 12 D=4.8 Part b 14
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. The compression fitting is a screw that adjusts and secures the insertion length of Temperature Sensors with the above protective tubing diameters. The material of the Compression Fitting is SUS304 with internal fixing beads made of brass.
a D Sensor side Protective tubing dia. Head side
Material
28 19 19 14
F-32
Loose Flanges
Model Information
Applicable protective tubing diameter 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. 10 dia. 12 dia. 15 dia. 22 dia. Model MF-1 D=3.2 MF-1 D=4.8 MF-1 D=6.4 MF-1 D=8 MF-2 D=10 MF-2 D=12 MF-2 D=15 MF-2 D=22
23 dia. 45 dia. 35 dia. 70 dia. 5 14 24 6.6 36 54 dia. 21 dia.
MF-1
120 Three, 5 dia.
MF-2
120 Three, 6.5 dia.
D dia.
M4
31 dia. D dia.
M6
Note: 1. Use the Loose Flange in atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C maximum. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. Material: Aluminum
Temperature Sensor
E52
F-33
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between 20C and 70C and two types of heat-resistive models for a temperature range between 0C and 150C are available. Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Thermocouple R Heat resistance Standard Heat resistive K (CA) Standard Heat resistive Exterior (Length) Fully vinyl-covered (waterproof) Fully glass-wool-covered Fully glass-wool-covered with external shield Fully vinyl-covered (waterproof) Fully glass-wool-covered Fully glass-wool-covered with external shield Silicone-covered (See note 2.) J (IC) Standard Heat resistive Vinyl covered (waterproof) Fully glass-wool-covered Fully glass-wool-covered with external shield 1m WPRG 1M WPRH 1M WPRH6 1M WCAG 1M WCAH 1M WCAH6 1M WICG 1M WICH 1M WICH6 1M 2m WPRG 2M WPRH 2M WPRH6 2M WCAG 2M WCAH 2M WCAH6 2M WICG 2M WICH 2M WICH6 2M Model 4m WPRG 4M WPRH 4M WPRH6 4M WCAG 4M WCAH 4M WCAH6 4M WICG 4M WICH 4M WICH6 4M 8m WPRG 8M WPRH 8M WPRH6 8M WCAG 8M WCAH 8M WCAH6 8M WICG 8M WICH 8M WICH6 8M
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above 100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details. 2. The WCAG-40 is suitable for moving parts. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.
Standard
RX-G
Fully vinyl-covered (waterproof) Fully glass-woolcovered Fully glass-woolcovered with external shield Fully vinyl-covered (waterproof) Fully glass-woolcovered Fully glass-woolcovered with external shield Silicone-covered
K (CA)
Standard
VX-G
4/0.65 7/0.3
20 to 70
0 to 150
2.5 3.0
Blue
0.39 1.07
WCAG-40
Heat resis- KX-G tive for moving parts J (IC) Standard JX-G
30/0.1
20 to 150
2.5
4.18
Fully vinyl-covered (waterproof) Fully glass-woolcovered Fully glass-woolcovered with external shield
4/0.65 7/0.3
20 to 70
0 to 150
2.5
Yellow
0.47 1.27
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. H905-E1-01 In the interest of product improvement, specifications are subject to change without notice.
F-34