The D3W is a 3-chamber, electrically controlled 4/3 or 4/2 way directional control valve. It is activated directly by solenoids with screwed in wet pin armature.
Technical data
General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Flow max. Leakage at 50 bar Static / Dynamic Step response at 95% Electrical characteristics Duty ratio Max. switching frequency Protection class Supply voltage / ripple Tolerance supply voltage Current consumption Current consumption Power consumption Power consumption Solenoid connection Wiring min. Wiring length max. Directional spool valve Solenoid DIN NG10 / CETOP 05 / NFPA D05 DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05 Unrestricted, preferably horizontal -25...+50 4.8 (1 solenoid), 6.3 (2 solenoids) P, A B: 350 T: 210 (DC), 105 (AC), 210 (AC Code H) Hydraulic oil in accordance with DIN 51524 / 51525 -25 ... +70 2.8...400 (2.8...400 cSt) 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) 150 (DC); 115 (AC) Up to 20 per flow path, depending on spool Energized: 105 (DC), 21 (AC) De-energized: 85 (DC), 35 (AC) 100% ED; CAUTION: coil temperature up to 150 C possible 10000 IP 65 in accordance with DIN 40050 (plugged and mounted) K J U G Y T 12 VDC 24 VDC 98 VDC 205 VDC 110V at 50Hz/ 230V at 50Hz/ 120V at 60Hz 240V at 60Hz 10 10 10 10 5 5 3 1.5 0.37 0.18 0.8 / 0.72 0.4 / 0.36 3 1.5 0.37 0.18 3.41 / 3.31 1.75 / 1.7 36 36 36 36 88 / 86 88 / 86 36 36 36 36 375 / 397 385 / 408 Connector as per EN 175301-803, solenoid identification as per ISO 9461. 3 x 1.5 recommended 50 recommended
[1/h] Code [V] [%] [A] [A] [W] [W] [mm] [m]
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D3W.PMD RH
2-41
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Ordering Code
D
Directional control valve
3
Size DIN NG 10 CETOP 5 NFPA D05 3-chamber valve
W
Wet pin armature solenoid, threaded in tube Spool type Style Seals
Spool type 0 b
Code N V
Spool type 0 b
D3W.PMD RH
2-42
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Ordering Code W
Solenoid voltage Solenoid connection Connector as per EN 175301-803, without plug Please order plug separately. See chapter 2, Accessories Solenoid tube options Manual override options
Design series
Not required for ordering
Code omit T
Code
Solenoid options Standard solenoid tube (105 bar AC, 210 bar DC) High pressure solenoid tube tank press. 210bar (only for AC)
omit
Code K J U G
2) 2)
Voltage 12V= 24V= 98V= 205V= 110V 50Hz / 120V 60Hz 230V 50Hz / 240V 60Hz
Y T
2) For
AC voltage use plug with rectifier. Please order rectifier plug separately.
2-43
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Flow Curve
The flow curve diagram shows the flow versus pressure drop curves for all spools shown. To read the values in the diagram, the curve number for the selected spool and
Position "b" Spool 1 2 3 4 P->A 4 4 4 4 4 4 5 4 4 4 4 5 5 4 4 4 P->B 8 9 4 4 P->A 21 22 5 P->A 3 B->T 3 1 3 2 3 3 1 3 3 3 2 3 3 2 A->T 3 4 Position "b" P->B 4 B->T 3 A->B 6 P->B 3 P->A 4 4 4 5 4 5 4 4 4 4 4 5 4 4 4 4 4 P->A 4 4 Position "a" P->B A->T 3 1 2 2 3 3 3 3 3 1 3 3 3 2 B->T 3 4 P->A 3 5 6 7 4 P->A -
Position "0" P->B 3 6 4 7 5 P->B A->T 1 4 3 8 7 2 A->T B->T 1 3 2 8 7 4 B->T P->T 5 6 8 6 P->T 6 6 A->B 1 5 6 8 A-> B -
5 6 7 10 11 12 14 15 16 20 26 30
Flow curve
Pressure drop [bar]
Flow [l/min]
D3W.PMD RH
2-44
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Shift Limits
The diagram below specifies the shift limits for valves with DC solenoids. Valves of style F and M may only be loaded at 70% of the value. The specifications apply to a viscosity of 35 mm2/s and equal flow at A and B port. Shift limits, DC voltage
Supply pressure [bar]
Flow [l/min]
2-45
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Dimensions
Interface EN 175301-803, DC solenoid B, E, F -style
2
C, D -style
6.5
6.5
6.5
H, K, M -style
6.5
6.5
C, D -style
6.5
Surface finish BK385 4x M6x40 DIN 912 12.9 11 Nm 15% NBR: SK-D3W-30 FPM: SK-D3W-V30
D3W.PMD RH
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
2-46