Noise Control | Vibration Isolation | Restraint Systems tel: 416-291-7371 fax: 416-291-8049 1-800-565-8401 1-888-811-2264 web: www.vibro-acoustics.com eml: info@vibro-acoustics.com File No.: DS-SIPS-007 Supersedes: DS-SIPS-006 DIME N SION S Model Date: 26 Jun 2012 Date: 15 Jun 2012

SIPS1.5/2/2.5/3

Nominal Pipe Size in mm

A Top Width in mm 7 178 8 203 9 229 10 254 11 1/2 292 12 1/2 318 13 1/2 343 15 1/2 394

A SIPS-1.5 SIPS-2 SIPS-2.5 SIPS-3 SIPS-4 12 (305 mm) to pipe centerline (approx. 12.75 (324 mm) operating height with isolation pads) SIPS-5 SIPS-6 SIPS-8 1 1/2 40 2 50 2 1/2 65 3 80 4 100 5 125 6 150 8 200

R Radius of Bolt Hole Centers in mm 1 15/16 49 2 3/8 60 2 3/4 70 3 76 3 3/4 95 4 1/4 108 4 3/4 121 5 7/8 149

X Bolt Hole Diameter in mm


5/8 16 3/4 19 3/4 19 3/4 19 3/4 19 7/8 22 7/8 22 7/8 22

Stand Weight lb kg 16.2 7.3 16.4 7.4 16.6 7.5 16.9 7.7 36.0 16.3 36.1 16.4 36.3 16.5 36.4 16.5

1/4 (6 mm) thick

neoprene grommet washer with 1/2 (13 mm) hole

NOTC H DIME N SION S Model N1 Width in mm SIPS-1.5 SIPS-2 SIPS-2.5 SIPS-3 SIPS-4 SIPS-5 SIPS-6 SIPS-8 0.94 24 1.06 27 1.06 27 1.06 27 1.06 27 1.19 30 1.19 30 1.19 30 N2 Length in mm 2.94 75 3.50 89 4.00 102 4.25 108 5.00 127 5.56 141 6.06 154 7.31 186 N1 N2

10 (254 mm)

14 (356 mm)

4(102 mm)

SIPS4/5/6/8

optional vibration isolation pads NSN 4445 with 1 1/2 (38 mm) hole A

R neoprene grommet washer with 5/8 (16 mm) hole X

PE RFORMANC E
3/8 (10 mm)

thick

Model

Max Allowed Lateral Load without NSN Pads* lb kg 900 408 2600 1179

Max Allowed Lateral Load with NSN Pads* lb kg 700 318 2000 907

14 (356 mm)

15 (381 mm) to pipe centerline (approx. 15.75 (400 mm) operating height with isolation pads)

SIPS-1.5/2/2.5/3 SIPS-4/5/6/8

* Max allowed load requires correct attachment to structure

18 (457 mm)

4(102 mm)

optional vibration isolation pads NSN 4465 with 1 1/2 (38 mm) hole

NOTE S Pump stands are designed for minimum 1g lateral load seismic force for most matching inline pumps. An analysis must be performed to ensure adequacy for project- specific conditions Stands are fabricated with high strength low alloy steel Bolt holes located to match ANSI 125 cast iron flange dimensions Pump stands are powder-coated enamel for corrosion protection Cutouts are sized to accommodate standard class 150 slip-on flanges Pump stands must be installed in pairs on inline pumps. See installation instructions for further information If mounted on a housekeeping pad, the pad must be seismically doweled to the structural slab Optional accessories include anchor bolts and isolation pads

Project: Customer: Consultant: Dwg No.: V-A Project Manager:


TAG : C OMMENT S :

plan view of stand locations

Model SIPS -

Accessories Isolation Pads Anchor Bolts*

Rev:

Drawn by:

pump

* Contact factory for seismic calculations to determine size